PS12 CITY OF TERRE HAUTE VIGO COUNTY, INDIANA DRAWING NO. EXISTING AND NEW STRUCTURE DATA TABLE JW, CM. No. DATE DESCRIPTION REVISED BY JLH ACS

Size: px
Start display at page:

Download "PS12 CITY OF TERRE HAUTE VIGO COUNTY, INDIANA DRAWING NO. EXISTING AND NEW STRUCTURE DATA TABLE JW, CM. No. DATE DESCRIPTION REVISED BY JLH ACS"

Transcription

1 C JW, CM EXISTING AND NEW STRUCTURE DATA TABLE PS12

2 #5933 NEW OUTFALL STRUCTURE #1 1"=60' EXISTING OPENING THROUGH TREE LINE ( SEWER AND OUTFALL STRUCTURE SHALL BE INSTALLED AT THIS LOCATION TO AVOID ANY TREE REMOVAL) MANHOLE #5 NEW POND OVERFLOW JUNCTION STRUCTURE #5A MANHOLE #4 MANHOLE #6 NEW POND OVERFLOW STRUCTURE #5989 #5988 NEW HIGH RATE CLARIFICATION TREATMENT FACILITY EXISTING/ABANDONED ELECTRICAL HOUSING STRUCTURE #4493 NEW HIGH RATE CLARIFICATION TREATMENT FACILITY (FUTURE PHASE II) NEW STORM MANHOLE #10 NEW HIGH RATE CLARIFICATION TREATMENT FACILITY (FUTURE PHASE III) NEW STORM MANHOLE #11 NEW WW NEW HRC DRAIN MANHOLE #8 NEW ELECTRICAL TRANSFORMER NEW STORM MANHOLE #12 NEW EMERGENCY GENERATOR MANHOLE #3 NEW HRC DRAIN MANHOLE #7 MANHOLE #1 NEW SITE PERIMETER CHAIN LINK FENCE (TYP) MANHOLE #2 NEW STORM OUTFALL STRUCTURE #2 NEW HRC DRAIN MANHOLE #9 NEW STORM MANHOLE #13 NEW STORM MANHOLE #14 NEW STORM MANHOLE #15 VALVE STRUCTURE #4 W.S. FORCE MAIN NEW W.S. WET WELL VALVE STRUCTURE #3 W.S. FORCE MAIN VALVE STRUCTURE #2 INFLUENT FORCE MAIN NEW STORM MANHOLE #16 EXISTING VALVE VAULT FOR ABANDONED WATER LINES FROM WELL #5933A ILLUSTRATES APPROXIMATE AREA A DELINEATED WETLAND (NO CONSTRUCTION SHALL TAKE PLACE WITHIN DESIGNATED AREAS, TYP) NEW PAVED ACCESS DRIVE PROPOSED POND #4451 NEW/RELOCATED OVERHEAD ELECTRIC LINES TO ACCOMMODATE NEW ACCESS DRIVE EXISTING GRAVEL ACCESS DRIVE NEW/RELOCATED POWER POLE TO ACCOMMODATE NEW ACCESS DRIVE VALVE STRUCTURE #1INFLUENT FORCE MAIN VALVE STRUCTURE #5 W.S. FORCE MAIN PLAN VIEW 1"=60'-0" C No. DATE DESCRIPTION REVISED BY JW, CM EXISTING SITE IMPROVEMENTS PLAN VIEW - NORTH HALF PS13

3 1"=100' NEW POND OVERFLOW JUNCTION STRUCTURE #5A NEW OUTFALL STRUCTURE #1 #5989 #5988 MANHOLE #5 MANHOLE #6 #4493 MANHOLE #4 NEW STORM MANHOLE #10 NEW POND OVERFLOW STRUCTURE MANHOLE #1 NEW HRC DRAIN MANHOLE # NEW CULVERTS MANHOLE #3 NEW STORM MANHOLE # MANHOLE # NEW WW NEW HIGH RATE CLARIFICATION TREATMENT FACILITY NEW STORM MANHOLE # VALVE STRUCTURE #3 W.S. FORCE MAIN NEW STORM MANHOLE #14 NEW STORM OUTFALL STRUCTURE #2 NEW STORM MANHOLE #13 NEW WASTE SLUDGE WET WELL NEW STORM MANHOLE #15 NEW STORM MANHOLE #16 NEW CULVERTS #5933A NEW HRC DRAIN MANHOLE #7 NEW HRC DRAIN MANHOLE #8 VALVE STRUCTURE #4 W.S. FORCE MAIN VALVE STRUCTURE #2 INFLUENT FORCE MAIN #4451 PROPOSED POND VALVE STRUCTURE #1INFLUENT FORCE MAIN VALVE STRUCTURE #5 W.S. FORCE MAIN ILLUSTRATES APPROXIMATE AREA A DELINEATED WETLAND (NO CONSTRUCTION SHALL TAKE PLACE WITHIN DESIGNATED AREAS, TYP) EXISTING DEPARTMENT NATURAL RESOURCES INGRESS/EGRESS EASEMENT (50' WIDE, TO REMAIN) NEW INFLUENT FORCE MAIN VALVE VAULT SITE PLAN VIEW 1"=100'-0" C No. DATE DESCRIPTION REVISED BY JW, CM NEW HIGH RATE CLARIFICATION TREATMENT FACILITY SITE PIPING PLAN VIEW PS16

4 1"=50' NEW OUTFALL STRUCTURE #1 NEW POND OVERFLOW JUNCTION STRUCTURE #5A INVERT PIPE N: E: MANHOLE #6 N: E: N: E: N: E: N: E: N: E: MANHOLE #5 N: E: NEW POND OVERFLOW STRUCTURE N: E: N: E: N: E: N: E: MANHOLE #4 N: E: NEW STORM MANHOLE #10 N: E: NEW STORM MANHOLE #11 N: E: SEE DRAWING PS21 FOR HRC FACILITY DIMENSIONING NEW STORM MANHOLE #12 N: E: NEW WW MANHOLE #1 N: E: MANHOLE #3 N: E: MANHOLE #2 N: E: NEW STORM MANHOLE #15 N: E: NEW STORM OUTFALL STRUCTURE #2 R50'-0 INVERT PIPE N: E: "=20' #5787 NEW HRC DRAIN MANHOLE #9 N: E: VALVE STRUCTURE #2 INFLUENT FORCE MAIN N: E: NEW STORM MANHOLE #16 N: E: NEW STORM MANHOLE #13 N: E: VALVE STRUCTURE #4 W.S. FORCE MAIN N: E: VALVE STRUCTURE #3 W.S. FORCE MAIN N: E: '-0 R1 N: E: NEW HRC DRAIN MANHOLE #7 N: E: N: E: NEW HRC DRAIN MANHOLE #8 N: E: " #5439 NEW STORM MANHOLE #14 N: E: NEW VALVE VAULT N: E: N: E: EXISTING MAIN LIFT STATION SITE PLAN VIEW EXISTING ELEVATED BRIDGE / WALKWAY 1"=50'-0" LIFT STATION SITE PLAN VIEW 1"=20'-0" C No. DATE DESCRIPTION REVISED BY JW, CM NEW HIGH RATE CLARIFICATION TREATMENT FACILITY OVERALL SITE DIMENSIONING PLAN VIEW PS20

5 "=30' 1. CONTRACTOR SHALL REFER TO STRUCTURE DATA TABLE FOR NORTHING AND EASTING INFORMATION TO LOCATE NEW STRUCTURES. 2. CONTRACTOR SHALL ENSURE NO CONFLICTS OCCUR WITH OTHER NEW SEWERS AND EXISTING SEWERS SCHEDULED TO REMAIN. 3. CONTRACTOR SHALL CONSTRUCT CONCRETE CRADLES AT ALL LOCATIONS WHERE NEW AND EXISTING PIPES CROSS WITHIN 18-INCHES VERTICALLY TO ENSURE PIPING IS ADEQUATELY SUPPORTED AND PROPER SPACING IS MAINTAINED AT MINIMUM, CRADLES SHALL BE CONSTRUCTED FROM SPRINGLINE TO SPRINGLING, HAVE A WIDTH EQUAL TO THE WIDTH THE TRENCH DUG TO INSTALL THE NEW PIPE, AND HAVE A LENGTH EQUAL TO 1.5 TIMES THE OUTSIDE DIAMETER THE LARGEST PIPE IN THE CROSSING. CRADLE SHALL BE CENTERED OVER THE PIPE BEING CROSSED. 4. CONTRACTOR SHALL EITHER DEMOLISH AND REMOVE OR ABANDON IN PLACE EXISTING SEWERS AND STRUCTURES THAT ARE INDICATED TO BE DEMOLISHED IN SITE PLAN DRAWINGS TO AVOID CONFLICTS WITH NEW SEWERS AND UTILITIES NEW OUTFALL STRUCTURE STA NEW MANHOLE #6 STA NEW STRUCTURE #5A STA NEW MANHOLE #5 STA NEW MANHOLE #4 STA NEW STRUCTURE #5A STA NEW POND OUTFALL STRUCTURE STA PLAN VIEW 1"=30'-0" PRILE OVERFLOW SEWER HORIZ. 1"=30'-0" VERTICAL 1"=5'-0" PRILE HORIZ. 1"=30'-0" VERTICAL 1"=5'-0" C JW, CM SEWER PLAN AND PRILE STA

6 1"=30' PLAN VIEW 1"=30'-0" 1. CONTRACTOR SHALL REFER TO STRUCTURE DATA TABLE FOR NORTHING AND EASTING INFORMATION TO LOCATE NEW STRUCTURES. 2. CONTRACTOR SHALL ENSURE NO CONFLICTS OCCUR WITH OTHER NEW SEWERS AND EXISTING SEWERS SCHEDULED TO REMAIN. C 3. CONTRACTOR SHALL CONSTRUCT CONCRETE CRADLES AT ALL LOCATIONS WHERE NEW AND EXISTING PIPES CROSS WITHIN 18-INCHES VERTICALLY TO ENSURE PIPING IS ADEQUATELY SUPPORTED AND PROPER SPACING IS MAINTAINED AT MINIMUM, CRADLES SHALL BE CONSTRUCTED FROM SPRINGLINE TO SPRINGLING, HAVE A WIDTH EQUAL TO THE WIDTH THE TRENCH DUG TO INSTALL THE NEW PIPE, AND HAVE A LENGTH EQUAL TO 1.5 TIMES THE OUTSIDE DIAMETER THE LARGEST PIPE IN THE CROSSING. CRADLE SHALL BE CENTERED OVER THE PIPE BEING CROSSED. 4. CONTRACTOR SHALL EITHER DEMOLISH AND REMOVE OR ABANDON IN PLACE EXISTING SEWERS AND STRUCTURES THAT ARE INDICATED TO BE DEMOLISHED IN SITE PLAN DRAWINGS TO AVOID CONFLICTS WITH NEW SEWERS AND UTILITIES. NEW MANHOLE #5 STA NEW MANHOLE #4 STA PRILE HORIZ. 1"=30'-0" VERTICAL 1"=5'-0" NEW MANHOLE #3 STA NEW MANHOLE #2 STA EX. 36" STORM STA DROP MANHOLE #1 STA EX. 66" TRUNK SEWER STA NEW UV STRUCTURE STA JW, CM SEWER PLAN AND PRILE STA

7 1"=50' GENERAL NOTES: 1. CONTRACTOR SHALL ENSURE NO CONFLICTS OCCUR WITH OTHER NEW SEWERS AND EXISTING SEWERS / UTILITIES SCHEDULED TO REMAIN. 2. CONTRACTOR SHALL CONSTRUCT CONCRETE CRADLES AT ALL LOCATIONS WHERE NEW AND EXISTING PIPES CROSS WITHIN 18-INCHES VERTICALLY TO ENSURE PIPING IS ADEQUATELY SUPPORTED AND PROPER SPACING IS MAINTAINED AT MINIMUM, CRADLES SHALL BE CONSTRUCTED FROM SPRINGLINE TO SPRINGLING, HAVE A WIDTH EQUAL TO THE WIDTH THE TRENCH DUG TO INSTALL THE NEW PIPE, AND HAVE A LENGTH EQUAL TO 1.5 TIMES THE OUTSIDE DIAMETER THE LARGEST PIPE IN THE CROSSING. CRADLE SHALL BE CENTERED OVER THE PIPE BEING CROSSED. 3. CONTRACTOR SHALL EITHER DEMOLISH AND REMOVE OR ABANDON IN PLACE EXISTING SEWERS AND STRUCTURES THAT ARE INDICATED TO BE DEMOLISHED IN SITE PLAN DRAWINGS TO AVOID CONFLICTS WITH NEW SEWERS AND UTILITIES. 1"=50'-0" EXISTING GRADE NEW ACCESS DRIVE NEW GRADE INV ± NEW 24" FORCE MAIN STA INV ± NEW 24" FORCE MAIN STA EXISTING 66" RCP TRUNK SEWER STA C HORIZ. 1"=30'-0" VERTICAL 1"=5'-0" 1 10/16/14 ADDENDUM No. 4 CM JW, CM NEW WATER MAIN PLAN AND PRILE STA

8 1"=50' GENERAL NOTES: NEW WATER METER PIT (SEE DETAIL DRAWING FOR MORE DETAILS) 1. CONTRACTOR SHALL ENSURE NO CONFLICTS OCCUR WITH OTHER NEW SEWERS AND EXISTING SEWERS / UTILITIES SCHEDULED TO REMAIN. 2. CONTRACTOR SHALL CONSTRUCT CONCRETE CRADLES AT ALL LOCATIONS WHERE NEW AND EXISTING PIPES CROSS WITHIN 18-INCHES VERTICALLY TO ENSURE PIPING IS ADEQUATELY SUPPORTED AND PROPER SPACING IS MAINTAINED AT MINIMUM, CRADLES SHALL BE CONSTRUCTED FROM SPRINGLINE TO SPRINGLING, HAVE A WIDTH EQUAL TO THE WIDTH THE TRENCH DUG TO INSTALL THE NEW PIPE, AND HAVE A LENGTH EQUAL TO 1.5 TIMES THE OUTSIDE DIAMETER THE LARGEST PIPE IN THE CROSSING. CRADLE SHALL BE CENTERED OVER THE PIPE BEING CROSSED. 3. CONTRACTOR SHALL EITHER DEMOLISH AND REMOVE OR ABANDON IN PLACE EXISTING SEWERS AND STRUCTURES THAT ARE INDICATED TO BE DEMOLISHED IN SITE PLAN DRAWINGS TO AVOID CONFLICTS WITH NEW SEWERS AND UTILITIES. 4. CONTRACTOR SHALL CONTACT INDIANA AMERICAN WATER TO MUTUALLY AGREE ON FINAL METER PIT AND TAP LOCATION PRIOR TO PERFORMING WORK. METER PIT SHALL BE LOCATED TO AVOID CONFLICTS WITH EXISTING UTILITIES. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ANY CONFLICTS OCCUR. 1"=50'-0" 5. CONTRACTOR SHALL COORDINATE WITH INDIANA AMERICAN WATER TO ENSURE A REPRESENTATIVE INDIANA AMERICAN WATER IS PRESENT WHEN TAP IS INSTALLED AT EXISTING WATER MAIN. CONTRACTOR SHALL COMPLETE A SERVICE RECORD CARD (PROVIDED BY INDIANA AMERICAN WATER) AT TIME TAP/METER PIT INSTALL. RETURN COMPLETED CARD TO INDIANA AMERICAN WATER. EXIST. OVERHEAD STA ELECTRIC LINES ABANDONED RAILROAD TRACK CROSSING STA ABANDONED RAILROAD TRACK CROSSING STA ABANDONED RAILROAD TRACK CROSSING STA EXISTING GRAVEL ACCESS DRIVE EXIST. OVERHEAD STA ELECTRIC LINES STA EXIST. GAS CROSSING CENTERLINE PRAIRIETON RD. CONNECT TO EXISTING WATER MAIN INV ± NEW WATER METER PIT STA CONNECT TO EXISTING 12" WATER MAIN STA HORIZ. 1"=30'-0" VERTICAL 1"=5'-0" C 1 10/16/14 ADDENDUM No. 4 CM JW, CM NEW WATER MAIN PLAN AND PRILE STA

9 3/8"=1'-0" 4' 0 4' 2-1/2" FLOOR DRAIN VENT PIPE TO EXIT OUT SIDE BUILDING CEILING 492' - 9" /2" ALUM. HANDRAIL WITH KICKPLATE (TYP) 36" x 36" SINGLE LEAF HEAVY DUTY TRAFFIC RATED ACCESS HATCH (SEE DETAILED SPECIFICATIONS FOR DETAILS, TYP 3) FINISHED FLOOR PLAN VIEW 478' - 9" PROPOSED GRADE 478' - 0" 3' - 0" x 3'-0" 3' - 0" 3' - 0" x 3'-0" 3' - 0" 3' - 0" x 3'-0" 25' - 4" ACCESS HATCH ACCESS HATCH ACCESS HATCH 6" WATER SUPPLY MAIN INFLUENT SUPPLY LINE TO YARD HYDRANTS W.S. PUMP (TYP 2) " POTABLE WATER SUPPLY LINE TO SINK AND RESTROOM DISCHARGE CENTER EL HOSE BIBB (TYP) LOWER LEVEL PLAN VIEW 459' - 9" 6" W.S. SUCTION LINE (TYP) HOUSEKEEPING PAD FOR W.S. PUMP (TYP 2) A Section A 3/8" = 1'-0" 6" STRAINER 6" "ZURN, MODEL 375 REDUCED PRESSURE PRINCIPLE ASSEMBLY" OR APPROVED EQUAL, BACKFLOW PREVENTER (TYP 2) 4" DRAIN LINE 20" ACTIFLO INFLUENT FORCE MAIN FROM EXISTING MAIN LIFT STATION CENTERLINE EL INFLUENT FORCE MAIN PIPE SUPPORT (REFER TO GENERAL NOTES ON P2-1 AND DETAILS ON MD8) C CEI Border.dwg REVISIONS 1 10/16/14 ADDENDUM No. 4 JW JW,CM 03/2014 PHASE 1 PROJECT 1-3 IMPROVEMENTS AT MAIN LIFT STATION PROJECT NEW ACTIFLO FACILITY SECTION VIEW A 88 P

10 CONTRACTOR SHALL ENSURE WATER SUPPLY IS INSTALLED ABOVE OVERHEAD DOOR AND DOES NOT INTERFERE (TYP AT ALL LOCATIONS) 1-1/ 1-1/ 1-1/ TANKLESS WATER HEATER FOR POLYMER MAKE-UP UNIT INFLUENT WATER 2" MOTORIZED BALL VALVE (CONNECT LINE TO ALUM SUPPLY LINE TO PUMP SKID FOR FLUSHING DURING HRC SYSTEM SHUT DOWN) HB-01 POLYMER MAKE-UP UNIT (SEE BLOW-UP THIS DRAWING) 3" WATER SUPPLY LINE TO YARD HYDRANTS INV. EL HB-02 DILUTION PANEL SINK TOILET 3/4" PW 1-1/ 1-1/ 6" WATER SUPPLY MAIN INV. EL " PW 6" WATER 3/4" PW TANKLESS WATER HEATER FOR SINK 3/4" PW 3/4" PW HB-04 TANKLESS WATER HEATER FOR UTILITY SINK 1-1/ UTILITY SINK 6" "ZURN, MODEL 375 REDUCED PRESSURE PRINCIPLE ASSEMBLY" OR APPROVED EQUAL, BACKFLOW PREVENTER (TYP 2) 6" STRAINER HB-03 HB /2" WATER SUPPLY LINE 3" PLUG FOR FUTURE WATER SUPPLY EXPANSION 1 WATER SCHEMATIC 2" MOTOR OPERATED BALL VALVE POLYMER MAKE-UP UNIT CONTROL PANEL NEW WATER HEATER NOTES: TANKLESS WATER HEATER C Tankless Water Heater for Polymer Make-up System. Water heater shall be an Eemax Series Two Model EX023240T2, or equal. Power requirements shall be 23 kw, 240 vac, and 96 (2x48)A to heat 4 GPM at a temperature rise of 39 F. Heater shall have two heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with ¾ NPT water connections. Provide unit with NEMA 4 enclosure. Tankless Water Heater for Restroom and Utility Sink. Water heater shall be an Eemax Series Two Model EX190TC, or equal. Power requirements shall be 19 kw, 240 vac, and 80 (2x40)A to heat up to 3 GPM at a temperature rise of 43 F. Heater shall have two heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with ¾ NPT water connections. Provide unit with NEMA 4 enclosure. 1" VALVE SUPPLY LINE FROM BASEMENT 3" VALVE POLYMER PROCESSING MODULE SUPPLY LINE (REDUCE AT POLYMER PROCESSING MODULE AS REQUIRED) 2 WATER SCHEMATIC-POLYMER MAKE-UP UNIT BLOW-UP 1/2" = 1'-0" 2" MOTORIZED BALL VALVE (CONNECT LINE TO POLYMER SUPPLY LINE TO PUMP SKID FOR FLUSHING DURING HRC SYSTEM SHUT DOWN) CEI Border.dwg REVISIONS 1 10/16/14 ADDENDUM No. 4 JW JW,CM 03/2014 PHASE 1 PROJECT 1-3 IMPROVEMENTS AT MAIN LIFT STATION PROJECT P2-15 NEW ACTIFLO FACILITY WATER DISTRIBUTION SCHEMATIC

11

12 3/8"=1'-0" 4' 0 4' CEILING " FLOOR DRAIN VENT PIPE TO EXIT OUT SIDE BUILDING 1-1/2" ALUM. HANDRAIL WITH KICKPLATE (TYP) 36"x36" SINGLE LEAF HEAVY DUTY TRAFFIC RATED ACCESS HATCH (SEE DETAILED SPECIFICATIONS FOR MORE DETAILS, TYP 3) FINISHED FLOOR PLAN VIEW PROPOSED GRADE ' - 0" x 3'-0" 3' - 0" 3' - 0" x 3'-0" 3' - 0" 3' - 0" x 3'-0" 4' - 7" OPENING OPENING OPENING 6" WATER SUPPLY MAIN INFLUENT 3" WATER SUPPLY LINE TO YARD HYDRANTS W.S. PUMP (TYP 2) LOWER LEVEL PLAN VIEW HOSE BIBB (TYP) 4" W.S. SUCTION LINE HOUSE-KEEPING PAD FOR W.S. PUMP (TYP 2) A Section A 3/8" = 1'-0" 6" STRAINER 6" "ZURN, MODEL 375 REDUCED PRESSURE PRINCIPLE ASSEMBLY" OR APPROVED EQUAL, BACKFLOW PREVENTER (TYP 2) 4" DRAIN LINE FROM TRENCH DRAIN TO SUMP PIT 20" COMAG INFLUENT FORCE MAIN FROM EXISTING MAIN LIFT STATION CENTERLINE EL INFLUENT FORCE MAIN PIPE SUPPORT (REFER TO GENERAL NOTES ON MA2-3 AND DETAILS ON DRAWING MD8) C CEI Border.dwg REVISIONS 1 10/16/14 ADDENDUM No. 4 JW JW,CM PHASE 1 PROJECT 1-3 IMPROVEMENTS AT MAIN LIFT STATION PROJECT MA2-6 NEW COMAG FACILITY SECTION VIEW A

13 CONTRACTOR SHALL ENSURE WATER SUPPLY IS INSTALLED ABOVE OVERHEAD DOOR AND DOES NOT INTERFERE (TYP AT ALL LOCATIONS) 1-1/ 1-1/ 1-1/ 1" NPW TANKLESS WATER HEATER FOR POLYMER MAKE-UP UNIT INFLUENT WATER 2" MOTORIZED BALL VALVE CONNECT TO ALUM SUPPLY LINE TO PUMP SKID FOR FLUSHING DURING HRC SYSTEM SHUT DOWN HB-01 POLYMER MAKE-UP UNIT (SEE BLOW-UP THIS DRAWING) 3" WATER SUPPLY LINE TO YARD HYDRANTS INV. EL " PW BLIND FLANGE 1" NPW TO SLUDGE PUMP SEAL WATER SYSTEM HB-02 DILUTION PANEL SINK 6" WATER SUPPLY MAIN INV. EL " "ZURN, MODEL 375 REDUCED PRESSURE PRINCIPLE ASSEMBLY" OR APPROVED EQUAL, BACKFLOW PREVENTER (TYP 2) 1" PW 6" NPW 3/4" PW TOILET TANKLESS WATER HEATER FOR SINK 3/4" PW 3/4" PW HB-04 TANKLESS WATER HEATER FOR UTILITY SINK UTILITY SINK HB-03 6" STRAINER HB /2" WATER SUPPLY LINE 2" WATER SUPPLY LINE 1 WATER SCHEMATIC 3" PLUG FOR FUTURE WATER SUPPLY EXPANSION 2" MOTOR OPERATED BALL VALVE POLYMER MAKE-UP UNIT CONTROL PANEL NEW WATER HEATER NOTES: Tankless Water Heater for Polymer Make-up System. Water heater shall be an Eemax Series Two Model EX023240T2, or equal. Power requirements shall be 23 kw, 240 vac, and 96 (2x48)A to heat 4 GPM at a temperature rise of 39 F. Heater shall have two heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with ¾ NPT water connections. Provide unit with NEMA 4 enclosure. TANKLESS WATER HEATER 1" VALVE C Tankless Water Heater for Restroom and Utility Sink. Water heater shall be an Eemax Series Two Model EX190TC, or equal. Power requirements shall be 19 kw, 240 vac, and 80 (2x40)A to heat up to 3 GPM at a temperature rise of 43 F. Heater shall have two heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with ¾ NPT water connections. Provide unit with NEMA 4 enclosure. SUPPLY LINE FROM BASEMENT 3" VALVE POLYMER PROCESSING MODULE SUPPLY LINE, REDUCE AT POLYMER PROCESSING MODULE AS REQUIRED 2 WATER SCHEMATIC-POLYMER MAKE-UP UNIT BLOW-UP 1/2" = 1'-0" 2" MOTORIZED BALL VALVE CONNECT TO ALUM SUPPLY LINE TO PUMP SKID FOR FLUSHING DURING HRC SYSTEM SHUT DOWN CEI Border.dwg REVISIONS 1 10/16/14 ADDENDUM No. 4 JW JW,CM PHASE 1 PROJECT 1-3 IMPROVEMENTS AT MAIN LIFT STATION PROJECT MA2-17 NEW COMAG FACILITY WATER DISTRIBUTION SCHEMATIC

14 SEAL WITH NON-SHRINK GROUT (TYP) 48" POND OVERFLOW SEWER PRECAST CONCRETE STRUCTURE. SEE DETAILED SPECIFICATION SECTION 13 FOR ADDITIONAL INFORMATION. OVERFLOW WEIR OPENING (TYP ALL 4 SIDES) 48"x48" OPENING THROUGH TOP SLAB (SHOWN OUT SECTION) FLOW 10' 10' LOWER LEVEL PLAN VIEW N.T.S. CONCRETE BENCH, BENCH HEIGHT EQUAL TO 0.8 PIPE DIAMETER (MINIMUM CONCRETE STRENGTH 2500 PSI). SLOPE AS INDICATED. UPPER LEVEL PLAN VIEW N.T.S. TRASH RACK. STORMRAX FLAT SERIES BY CONTECH ENGINEERS SOLUTIONS, OR EQUAL. SIZE TO COVER OPENING IN TOP SLABS. TRASH RACK. STORMRAX FLAT SERIES BY CONTECH ENGINEERS SOLUTIONS, OR EQUAL. SIZE TO COVER OPENING IN TOP SLAB TOP STRUCTURE " MIN OVERFLOW WEIR EL " 1'-6" 7' 1'-6" OVERFLOW WEIR OPENING (TYP ALL 4 SIDES) PRECAST CONCRETE STRUCTURE. SEE DETAILED SPECIFICATION SECTION 13 FOR ADDITIONAL INFORMATION. 15 MIN. 48" POND OVERFLOW SEWER CONCRETE BENCH, BENCH HEIGHT EQUAL TO 0.8 PIPE DIAMETER (MINIMUM CONCRETE STRENGTH 2500 PSI). SLOPE AS INDICATED TOP BASE SLAB INV SECTION VIEW N.T.S.

15 CONCRETE BENCH, BENCH HEIGHT EQUAL TO 0.8 PIPE DIAMETER (MINIMUM CONCRETE STRENGTH 2500 PSI). SLOPE 1" PER FOOT TO WALL. SHAPE TO ACCOMMODATE 48" POND OVERFLOW FLAP GATE AS REQUIRED. SEAL WITH NON-SHRINK GROUT (TYP) 10'x10' PRECAST CONCRETE STRUCTURE NOTE: 1. STAINLESS STEEL FLAP GATE SHALL BE AS SPECIFIED IN DETAIL SPECIFICATION SECTION 18. FACE MOUNT TO INSIDE WALL PRECAST STRUCTURE AT END PIPE IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS. DESIGN FOR A MAXIMUM DESIGN HEAD EQUAL TO 25 FEET. 54" HRC EFFLUENT SEWER FLOW EMBEDDED CASTING WITH BOLT DOWN SOLID LID (IN TOP SLAB) 48" POND OVERFLOW SEWER 48" STAINLESS STEEL FLAP GATE EMBEDDED CASTING WITH BOLT-DOWN SOLID LID PLAN VIEW N.T.S TOP STRUCTURE 10'x10' PRECAST CONCRETE STRUCTURE CONCRETE BENCH, BENCH HEIGHT EQUAL TO 0.8 PIPE DIAMETER (MINIMUM CONCRETE STRENGTH 2500 PSI). SLOPE 1" PER FOOT TO WALL. SHAPE TO ACCOMMODATE 48" POND OVERFLOW FLAP GATE AS REQUIRED. 48" STAINLESS STEEL FLAP GATE SEAL WITH NON-SHRINK GROUT (TYP) INV= " HRC EFFLUENT SEWER INV INV CONCRETE FILL UNDER PIPE (TYP) SECTION VIEW N.T.S TOP BASE SLAB

16

APPROXIMATE LIMIT OF CITY LANDFILL LIMIT OF CONTRACTOR WORK ZONE. INSTALL CONSTRUCTION SNOW FENCE.

APPROXIMATE LIMIT OF CITY LANDFILL LIMIT OF CONTRACTOR WORK ZONE. INSTALL CONSTRUCTION SNOW FENCE. EX. 5Ø WM EX. 6Ø SAN EX. 4Ø STM EX. 5Ø SAN EX. 75Ø SAN APPROXIMATE LIMIT OF CITY LANDFILL ZONE. INSTALL CONSTRUCTION SNOW FENCE. STUB FOR FUTURE 6Ø WATERMAIN 4 6 8 ZONE. INSTALL CONSTRUCTION SNOW FENCE.

More information

CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS

CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS 2010 EDITION CITY OF OZARK, MISSOURI REVISIONS TO THE 2009 EDITION The following revisions have been made to the 2009 edition of the city

More information

Standard Drawings Table of Contents

Standard Drawings Table of Contents Standard Drawings Table of Contents 1. Standard Symbols, Abbreviations, & Legends 2. 1 Water Service 3. 1 ½ or 2 Water Service 4. 3 Water Service 5. 1 ½ 3 Water Service Manifold Assembly 6. 2 Blow Off

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

BREWSTER SR173 PROPOSED: OKANOGAN RIVER PADDLERS CAMPGROUND WATERBODY: OKANOGAN RIVER NEAR: BREWSTER COUNTY: OKANOGAN STATE: WASHINGTON

BREWSTER SR173 PROPOSED: OKANOGAN RIVER PADDLERS CAMPGROUND WATERBODY: OKANOGAN RIVER NEAR: BREWSTER COUNTY: OKANOGAN STATE: WASHINGTON OKANOGAN RIVER PROJECT LOCATION SR53 COLUMBIA RIVER SR73 METHOW RIVER PATEROS SR7 SR7 BRIDGEPORT VICINITY MAP NEAR: VICINITY 2 GEBBERS FARMS INC APN 302570024 STATE HWY 7 DOUGLAS CO. PUD NO. APN 302570037

More information

DEPARTMENT OF PUBLIC WORKS & UTILITIES

DEPARTMENT OF PUBLIC WORKS & UTILITIES CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS & UTILITIES URBAN SERVICES STANDARDS AND GUIDELINES January 2017 Craig Fulton, P.E., Director TABLE OF CONTENTS "URBAN SERVICES STANDARDS AND GUIDELINES"

More information

County of El Dorado Standard Plans

County of El Dorado Standard Plans County of El Dorado Standard Plans Table of Contents Section 1 General Standards GS-01 General Legend and Abbreviations Section 2 Roads and Streets RS-01 RS-02 RS-03 RS-04 RS-05 RS-06 RS-07 RS-08 RS-20

More information

VEHICULAR AND PEDESTRIAN CIRCULATION

VEHICULAR AND PEDESTRIAN CIRCULATION This perspective sketch communicates the intended character and quality of a proposed streetscape design. Locate benches near a major intersection where people tend to gather. Seating and lighting provide

More information

STORMWATER - GENERAL NOTES

STORMWATER - GENERAL NOTES STORM DRAINAGE CONSTRUCTION NOTES. All storm sewer pipe shall be reinforced concrete. 2. Storm drainage pipes shall be a minimum of fifteen (5) inch diameter (5" for short lateral runs only - up to 75

More information

SITE PLAN REVIEW APPLICATION

SITE PLAN REVIEW APPLICATION SITE PLAN REVIEW APPLICATION CITY OF THE DALLES Community Development Department 313 Court Street The Dalles, OR 97058 (541) 296-5481, ext. 1125 Fax (541) 298-5490 www.ci.the-dalles.or.us Date Filed File#

More information

APPENDIX F: DETAIL DRAWINGS

APPENDIX F: DETAIL DRAWINGS APPENDIX F: DETAIL DRAWINGS DRAWING DIVISION 100 GENERAL NOTES 200 ROAD WAYS 300 TRAFFIC CONTROL 400 FENCES 500 SEDIMENT CONTROL 600 SANITARY AND STORM SEWERS 700 WATERMAIN 800 PARKS AND LANDSCAPING 900

More information

PLANNED UNIT DEVELOPMENT APPLICATION

PLANNED UNIT DEVELOPMENT APPLICATION PLANNED UNIT DEVELOPMENT APPLICATION CITY OF THE DALLES Community Development Department 313 Court Street The Dalles, OR 97058 (541) 296-5481, ext. 1125 Fax (541) 298-5490 www.ci.the-dalles.or.us Date

More information

FEATURES. Other Fed-Flush Arrangements

FEATURES. Other Fed-Flush Arrangements Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the

More information

A. Regional Detention Requirements

A. Regional Detention Requirements I. GENERAL DESIGN GUIDELINES A. Full-spectrum detention is provided for all new development, redevelopment or expansion of a site to provide for water quality and flood control detention. B. Detention

More information

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING

More information

HUNTSVILLE PHYSICAL SERVICES DEPARTMENT

HUNTSVILLE PHYSICAL SERVICES DEPARTMENT HUNTSVILLE PHYSICAL SERVICES DEPARTMENT URBAN DEVELOPMENT SITE PLAN CONTROL DRAWING DESIGN GUIDE April, 2000 (Revised June, 2003) TABLE OF CONTENTS Part A. General Information Page 1 Part B. Site Servicing

More information

CITY OF LATHROP. Department of Public Works. DESIGN & CONSTRUCTION Standard Details

CITY OF LATHROP. Department of Public Works. DESIGN & CONSTRUCTION Standard Details CITY OF LATHROP Department of Public Works DESIGN & CONSTRUCTION Standard Details January 2014 General G-1A Signature Blocks G-1B Signature Blocks G-2 Drafting Standards G-3 Drafting Standards G-4 Drafting

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

SITE PLAN REVIEW APPLICATION AND CHECKLIST

SITE PLAN REVIEW APPLICATION AND CHECKLIST SITE PLAN REVIEW APPLICATION AND CHECKLIST PROJECT SUMMARY: Project Name: City/ETA Location: City ETA (Application fee & number of copies needed are based on location) Property Location (Legal Description

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

6. Drawing E29: Replace E29 with attached RE29, provided in Attachment #1.

6. Drawing E29: Replace E29 with attached RE29, provided in Attachment #1. Section 40 95 Process Control Panels and Hardware: ) Paragraph.05.M.7.A Replace Ruckus Zone Director 00 Controller with Ruckus Zone Director 000 Controller. ) Paragraph.05.M.7.b Add Qty. 7 ) Paragraph.05.M.7.c

More information

OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES

OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES THE CARMONY BUILDING PARAGON REALTY NORTH GREEN STREET BROWNSBURG, HENDRICKS COUNTY INDIANA 8365 Keystone Crossing, Suite 201 Indianapolis,

More information

SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (PARALLEL)

SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (PARALLEL) SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (PARALLEL) W-1/S-3 SEPARATION AND CONSTRUCTION REQUIREMENTS FOR SEWER AND WATER LINES (CROSSINGS) W-2/S-4 TYPICAL TRENCH BACKFILL DETAILS

More information

STORM DRAINAGE CONSTRUCTION NOTES LENGTH RUN * See Note 2., Above or greater 500

STORM DRAINAGE CONSTRUCTION NOTES LENGTH RUN * See Note 2., Above or greater 500 STORM DRAINAGE CONSTRUCTION NOTES 1. ALL STORM SEWER PIPE SHALL BE REINFORCED CONCRETE UNLESS APPROVED BY THE CITY ENGINEER. 2. STORM DRAINAGE PIPES SHALL BE A MINIMUM OF FIFTEEN (15) INCH DIAMETER (15"

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

DESIGN SCENE SUBJECT INDEX

DESIGN SCENE SUBJECT INDEX DESIGN SCENE SUBJECT INDEX CHAPTER 1: TITLE SHEET and GENERAL LAYOUT AREA OF ENVIRONMENTAL SENSITIVITY BRIDGE & APPROACH PLANS CONSTRUCTION PLAN FOR EXCEPTIONS EXCEPTION CLARIFICATION GOVERNING SPECIFICATIONS

More information

Procurement Department ADDENDUM # 1

Procurement Department ADDENDUM # 1 To: 1012-909-62-3408 RFP for: Unit Make Ready Services Procurement Department ADDENDUM # 1 Change the closing date as follows: Responses are due 11:00a.m. Tuesday, March 15, 2011. Please note the following

More information

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation. Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From

More information

ABBREVIATIONS: TABLE OF CONTENTS: REFERENCE MATERIALS: CITY OF SEATTLE COMBINED SEWER OVERFLOW GALLONS PER MINUTE POLYVINYL CHLORIDE SQUARE FEET

ABBREVIATIONS: TABLE OF CONTENTS: REFERENCE MATERIALS: CITY OF SEATTLE COMBINED SEWER OVERFLOW GALLONS PER MINUTE POLYVINYL CHLORIDE SQUARE FEET TABLE OF CONTENTS: ABBREVIATIONS: SHEET NO. A SHEET DESCRIPTION REFERENCE SHEETS TITLE SHEET COS CSO GPM PVC SF CITY OF SEATTLE COMBINED SEWER OVERFLOW GALLONS PER MINUTE POLYVINYL CHLORIDE SQUARE FEET

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

TABLE OF CONTENTS I-1 INTRODUCTION TO STANDARD DESIGNS 03/17/08

TABLE OF CONTENTS I-1 INTRODUCTION TO STANDARD DESIGNS 03/17/08 TABLE OF CONTENTS Sheet Number Title Revision Date I-1 INTRODUCTION TO STANDARD DESIGNS 03/17/08 STREETS ST-1 LOCAL STREETS 03/17/08 ST-1A LOCAL STREETS, 2015 GENERAL PLAN 11/15/04 ST-2 COLLECTOR AND ARTERIAL

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

SPECIFICATION SECTION:

SPECIFICATION SECTION: SPECIFICATION SECTION: Date: STORM WATER TREATMENT STORMEXX CLEAN CATCH BASIN INSERTS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the Inserts for use at existing storm water catch basins in roadways,

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

Orange Township Fire Department Fire Prevention Bureau

Orange Township Fire Department Fire Prevention Bureau Orange Township Fire Department Fire Prevention Bureau Under Ground Fire Protection Plan Submittal Checklist Project Name: Project Address: Date: Designers Name: Company Name: Phone Number: Email: Fax:

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Gulfport, Mississippi 21 May 2007

Gulfport, Mississippi 21 May 2007 G PLUMBING GENERAL REQUIREMENTS The D-BC shall design the plumbing system to comply with this criteria and the Plumbing Code. Piping shall be shown on the same plan as the fixtures being served. Pipe size

More information

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following: SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.

More information

The open space system should provide connective elements, relate to natural resources, and enhance the suburban character of the landscape..

The open space system should provide connective elements, relate to natural resources, and enhance the suburban character of the landscape.. The open space system should provide connective elements, relate to natural resources, and enhance the suburban character of the landscape.. Mixed-use and infill development should maintain or enhance

More information

Home Inspection Report

Home Inspection Report Pfeifer Home Inpsection, LLC 8332 Crystal Pointe Lane Indianapolis, Indiana 46236 317-340-1734 Lic #HI01700103 Home Inspection Report Columbus, IN 47201 Page 1 of 20 Table of Contents Definitions 2 General

More information

PART TWO: PROJECT SPECIFIC DESIGN GUIDELINES

PART TWO: PROJECT SPECIFIC DESIGN GUIDELINES PART TWO: PROJECT SPECIFIC DESIGN GUIDELINES 2.1.0 GENERAL REQUIREMENTS: 1. Approved warm season turf varieties shall be used for LMD/CFD, commercial, industrial, and public landscape areas. The use of

More information

ROME CANALWAY TRAIL ERIE BOULEVARD WEST AND SOUTH CHARLES STREET ROME, NEW YORK DELTA PROJECT NO SEPTEMBER 2017 ISSUED FOR BID

ROME CANALWAY TRAIL ERIE BOULEVARD WEST AND SOUTH CHARLES STREET ROME, NEW YORK DELTA PROJECT NO SEPTEMBER 2017 ISSUED FOR BID ROME CANALWAY TRAIL ERIE BOULEVARD WEST AND SOUTH CHARLES STREET ROME, NEW YORK 13440 DELTA PROJECT NO. 2017.226.001 SEPTEMBER 2017 ISSUED FOR BID INDEX OF DRAWINGS GENERAL CIVIL ARCHITECT/ENGINEER PROJECT

More information

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS The Design Guidelines, which follow, are intended to supplement the Educational Specifications and State Requirements for Educational Facilities (SREF). Note: All fittings shall be installed by no less

More information

TOWN OF SPENCER FIRE and EMERGENCY SERVICES

TOWN OF SPENCER FIRE and EMERGENCY SERVICES TOWN OF SPENCER FIRE and EMERGENCY SERVICES Fire Prevention and Protection Regulations For Sub divisions 1. General requirements 2. Hydrants 3. Fire Cisterns Chapter 4. Dry Hydrants 5. Residential Sprinklers

More information

Report or technical documentations of the target areas in Siauliai

Report or technical documentations of the target areas in Siauliai WP 4 Energy Supply Report or technical documentations of the target areas in Siauliai 2011.10.27 Summary of the draft version of technical documentation for two target areas Lieporiai park 1.1. Works basis

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

n1. Design 5.4.6a Urban Bioretention 5.4.6a Urban Bioretention Variations: Planter box, Extended tree pits, Stormwater curb extensions.

n1. Design 5.4.6a Urban Bioretention 5.4.6a Urban Bioretention Variations: Planter box, Extended tree pits, Stormwater curb extensions. 5.4.6a Urban Bioretention Variations: Planter box, Extended tree pits, Stormwater curb extensions. Description: Urban bioretention SCM are similar in function to regular bioretention practices except they

More information

A: Downtown Diversion Pipe

A: Downtown Diversion Pipe A: Downtown Diversion Pipe b c with modifications Map highlighting conservation easement. The diversion pipe would run along the railroad. Will divert 40-44% of total flow.; and Reduce the impact on Sand

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

TENTATIVE MAP CHECKLIST

TENTATIVE MAP CHECKLIST Business License 707.648.4357 www.cityofvallejo.net Central Permit Center 555 Santa Clara Street Vallejo CA 94590 Building 707.648.4374 Planning 707.648.4326 TENTATIVE MAP CHECKLIST Public Works/Engineering

More information

TM Series. Induced Draft, Counter Flow Optional Accessories

TM Series. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

3.1 Survey Monument Preservation Guidelines for New and Reconstruction Projects. B. After construction and prior to recording Notice of Completion:

3.1 Survey Monument Preservation Guidelines for New and Reconstruction Projects. B. After construction and prior to recording Notice of Completion: 3.0 SURVEY 3.1 Survey Monument Preservation Guidelines for New and Reconstruction Projects A. Prior to construction: 1. Public survey records are to be researched for the location of all possible survey

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

SILT FENCE MACHINE SLICED ERO-1A STEEL FENCE POST (T-POST), MINIMUM 5' LONG, 6' MAXIMUM SPACING.

SILT FENCE MACHINE SLICED ERO-1A STEEL FENCE POST (T-POST), MINIMUM 5' LONG, 6' MAXIMUM SPACING. STEEL FENCE POST (T-POST), MINIMUM 5' LONG, 6' MAXIMUM SPACING. ATTACH FABRIC TO POSTS WITH MINIMUM 3 ZIP TIES (50 LB. TENSILE) PER POST IN TOP 8" OF FABRIC. MONOFILAMENT GEOTEXTILE FABRIC PER MNDOT TABLE

More information

Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit. Installation Instructions

Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit. Installation Instructions Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit Installation Instructions Introduction The EFM-INV-M, EFM-INV2, and EFM-INV3 Inverted Mounting Kits will allow you to mount your EFM-100 or

More information

Kingswood Site Development Preliminary Site Evaluation Report March 23, 2015

Kingswood Site Development Preliminary Site Evaluation Report March 23, 2015 By: Burgess & Niple, Inc. For: Deerfield Township Trustees Purpose: Kingswood Site Development Preliminary Site Evaluation Report March 23, 2015 This report will review the critical site issues that will

More information

Facility Improvements

Facility Improvements AP-SI-03 BICYCLE RACK ADDITION AP-SI-05 EXTERIOR BENCH ADDITIONS Installation of bike rack will allow for designated and secure storage of bicycles. Installation of exterior benches will provide an outdoor

More information

WLP & WCP Series Water Treatment Systems 2015

WLP & WCP Series Water Treatment Systems 2015 WLP & WCP Series Water Treatment Systems 2015 Mi-T-M Water Treatment Systems provide a better tomorrow by protecting our environment today. A Water Treatment System has the potential of saving hundreds

More information

Owners Manual for the Rainmaster Water Recycling System

Owners Manual for the Rainmaster Water Recycling System Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your

More information

STANDARD DETAILS QUICK REFERENCE

STANDARD DETAILS QUICK REFERENCE STANDARD DETAILS QUICK REFERENCE Note: DWGs need to be saved locally before opening file. Requires AutoCad, DWG TrueView, or Autodesk Design Review (the later two are available for free from http://usa.autodesk.com/)

More information

CRESCENT RESOURCES INC.

CRESCENT RESOURCES INC. CRESCENT RESOURCES INC. Due Diligence Checklist Project Name: Client: Project No. Date: 1 Survey Review survey for compliance with Crescent Resources, Inc. s Instructions to Surveyors (see below): All

More information

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information Lease Outline Drawing Lakeland Retail Center 4000 US Hwy. 98, Unit HH Gregg, Lakeland, FL 33809 ±26' ±200' Lease Line Unit HH Gregg ±46' Lease Line ±21' Unit HH Gregg ±145' Lease Line ± 30,000 SF Width

More information

A/E REVIEW CHECKLIST SITE & LANDSCAPE

A/E REVIEW CHECKLIST SITE & LANDSCAPE A/E REVIEW CHECKLIST SITE & LANDSCAPE Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Architectural, Boiler Safety Devices Operation

More information

STANDARD SPECIFICATIONS Book 2 ENGINEERING DRAWINGS INCLUDES ADDENDUMS

STANDARD SPECIFICATIONS Book 2 ENGINEERING DRAWINGS INCLUDES ADDENDUMS STANDARD SPECIFICATIONS Book 2 ENGINEERING DRAWINGS INCLUDES ADDENDUMS July 23, 2018 Page 1 of 7 STANDARD LEGEND SYMBOLS (September, 1973)... AS-101A STANDARD LEGEND SYMBOLS (September, 1973)... AS-101B

More information

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

REAR. Exit 5'-9 6'-1 8'-3 6'-1 Freezer Entrance Stall North Bridges REAR 67' 8' 29' Unit # 120 10955 Jones Bridge Rd. Alpharetta, GA 30022 8' 6'-10" Freezer 7'-1" CONTINENTAL REALTY CORP. 1427 Clarkview Road Suite 500 Baltimore, MD 21209 12' 13'-3" 6' 11'-11"

More information

Final Report: Appendix C. LID Parking Lot Design and Teaching Tool at Bridgewater State University, Bridgewater Supporting Information

Final Report: Appendix C. LID Parking Lot Design and Teaching Tool at Bridgewater State University, Bridgewater Supporting Information Bridgewater State University Virtual Commons - Bridgewater State University Phase II Final Report Taunton River Watershed Project 2011 Final Report: Appendix C. LID Parking Lot Design and Teaching Tool

More information

Figure Example of out door dining in the public right-of-way.

Figure Example of out door dining in the public right-of-way. Section 2 Core Area Goal 2.2.1 To maintain and enhance the character of existing streets in the Downtown Area. Character Figure 2.2.1 Example of out door dining in the public right-of-way. A. Provide street

More information

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following: SECTION 15440 PART I - GENERAL 1.01 WORK INCLUDED A. Types of plumbing fixtures required for the project include the following: 1. Water Closets 2. Urinals 3. Lavatories 4. Mop Sink 5. Sinks 6. Electric

More information

CITY OF PASADENA FIRE DEPARTMENT

CITY OF PASADENA FIRE DEPARTMENT Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in

More information

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60' ±60' Lease Line Lease Outline Drawing Needles Towne Center 1004 E. Broadway St.,, Needles, CA 92363 ± 900 SF Width ± 15' Depth ± 60' Plans produced by: ID Plans 6/16/2017 (813) 657-2545 C 2017 Site map

More information

OPERATION & MAINTENANCE

OPERATION & MAINTENANCE OPERATION & MAINTENANCE Nutrient Separating Baffle Box A Complete Stormwater Filtration System TM Bio Clean Environmental Services, Inc. www.biocleanenvironmental.com P.O. Box 869 P 760-433-7640 Oceanside,

More information

FLUSH MOUNT 6' SIDEWALK PAINTED WITH COURT DELINEATIONS REMOVABLE BOLLARD, TYP. PRIVATE ALLEY CURB AND GUTTER (STREET NAME TO BE DETERMINED)

FLUSH MOUNT 6' SIDEWALK PAINTED WITH COURT DELINEATIONS REMOVABLE BOLLARD, TYP. PRIVATE ALLEY CURB AND GUTTER (STREET NAME TO BE DETERMINED) P:\COLUMBIA GROVE\DWG\SHEETS\.. Submittal\L.0.dwg Xrefs: A-tb-W6 L-mp-W6-Phase L-sp-W6-Phase A-sp-W6-FP0 Phase 768L-SV L-tb-W6-Key Plan,) WALK TRASH AND RECYCLING RECEPTACLES WITH " STABILIZED MULCH PLAY

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

PALO ALTO HIGH SCHOOL Palo Alto Unified School District MEETING NOTES. DATE: 21 September Palo Alto HS Update

PALO ALTO HIGH SCHOOL Palo Alto Unified School District MEETING NOTES. DATE: 21 September Palo Alto HS Update PALO ALTO HIGH SCHOOL Palo Alto Unified School District MEETING NOTES DATE: 21 September 2010 SUBJECT: Landscape Subcommittee Meeting Palo Alto HS Update The purpose of the meeting was to update the Landscape

More information

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with

More information

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Port of St Helens SIA Aircraft Hanger Scappoose, OR Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance

More information

City of Mt. Juliet Planning & Zoning Department. Site Plan Checklist. Site plan cklist v1.18

City of Mt. Juliet Planning & Zoning Department. Site Plan Checklist. Site plan cklist v1.18 City of Mt. Juliet Planning & Zoning Department Site Plan Checklist Site Plan approval is required for all specified community facilities, all commercial, industrial, and multi-family residential activities

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12 12 24 SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: WALL ESCUTCHEON PACK ANNULAR SPACE WITH MINERAL WOOL GENERAL NOTES. THIS PROJECT INCLUDES THE DESIGN AND PROVISION OF A NEW WET SPRINKLER

More information

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR ELECTRIC ON-DEMAND TANKLESS WATER HEATERS: SpecAdvantage with PhD Technology SafeAdvantage with PhD Technology 208 and 480 VAC three phase 32 144 kw 600

More information

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2014. All rights reserved. No part of this publication may be reproduced by

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

LABOUR RATES FOR PLUMBING CONTRACTORS. A guide to the labour costs of plumbing works LABOUR RATES FOR PLUMBING CONTRACTORS

LABOUR RATES FOR PLUMBING CONTRACTORS. A guide to the labour costs of plumbing works LABOUR RATES FOR PLUMBING CONTRACTORS LABOUR RATES FOR PLUMBING CONTRACTORS A guide to the labour costs of plumbing works MORE MONEY IN YOUR POCKET September 06-1 - Increasers Labour Time Required In Hours DURAVENT STYLE INCREASER 75-100MM

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

How To Size A Big Dipper Unit

How To Size A Big Dipper Unit Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size

More information

Community Development Department Commercial Permit Application

Community Development Department Commercial Permit Application Commercial Permit Application Permit # Property Project Information Address Suite # Business Name Parcel # Fire Department County Type of Improvement (check all that apply) New Addition Alteration Repair

More information

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9 Deep Bowl cupc Certified Available in a 54" Bowl Size 9" Deep Bowl, Designed for Heavy Duty Hand Washing Foot, Air Metering, Infrared or TouchTime Control Specifications Size and Capacity Accommodates three users

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

Card Access Control Specifications

Card Access Control Specifications 1.0 Qualifications Card Access Control Specifications 1.01 Vendors must be pre-qualified for card access on the SHSU campus. 2.0 General Requirements and Notes 2.00 SHSU requires that all exterior doors

More information

These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. Overview of all pumps.

These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. Overview of all pumps. Pumps These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. 1. Pumps for a variety of requirements - yours too. Whether a flooded basement, for the drainage of construction sites

More information

GUIDELINES FOR PERMEABLE SIDEWALK-LANDSCAPING PERMIT

GUIDELINES FOR PERMEABLE SIDEWALK-LANDSCAPING PERMIT GUIDELINES FOR PERMEABLE SIDEWALK-LANDSCAPING PERMIT Green spaces are vital to San Francisco s quality of life as they provide a range of environmental benefits and bring beauty to our neighborhoods and

More information

Essential Skills: Reading and Interpreting Maps and Plans

Essential Skills: Reading and Interpreting Maps and Plans Essential Skills: Reading and Interpreting Maps and Plans Prepared for: NYS Tug Hill Commission Local Government Conference March 31, 2016 Prepared by: Peter G. Vars, P.E. BME ASSOCIATES Stages of Plan

More information