Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016

Size: px
Start display at page:

Download "Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016"

Transcription

1 Replacement Parts List No Revision K 07/06 Daikin McQuay Roofpak Evaporative Condensing Units RPE, RDE Tons Vintage C To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 6 Nomenclature & Unit Layout Unit Model & Serial Number... 7 Unit Section Locations... 8 Control Component Locations... 9 Unit Model Number Code Index... 0 Unit Model Number- Complete Electrical Legend Section A- Outdoor Air/Return Air/Economizer Section Notes % Outside Air Damper with Hood & No Return Air Plenum % Outside Air Damper % Economizer Section with Barometric Exhaust Damper & Return Air Fan % Economizer Section with Prop Exhaust Fan & Damper % Economizer Damper w/ Actuator ACT3... 8, 9 California Title 4 Assembly: Code 33= *F*** Return Air Plenum Isolation Damper w/ Actuator ACT6... 3, 3 Prop Exhaust Fan & Damper Prop Exhaust Fan Inverters Prop Exhaust Fan Control Box... 35, 36 Design Flow Return Air Fan...38 Return Air Fan Fan Mounts: Code = 44B* (Until /04) Return Air Fan Fan Mounts: Code = 44B* (/04 & Later) Return Air Fan Motors... 4, 4 Section Mounted Controls- OAE, OAT, RAE, RAT, SD, LT, S, REC Section B- Draw-Thru Filter Section Notes Section Mounted Controls- PC5, LT3, S3, & REC3, Magnehelic/Differential Pressure Gauges Filters... 45, 46 Section C- Blank/Inverter (AFD/VFD) Section Notes Section Mounted Controls- LT9, S9, & REC Section D- Draw-Thru Cooling Section Notes Evaporator Coils & Drain Pans Small Face DX Evaporator Coils: Code 03= S Large Face DX Evaporator Coils: Code 03= L Section E- Draw-Thru Spacer Section Notes... 5 Section E- Draw-Thru Heat Section for RDE Units Notes... 5 Section Mounted Controls- LT8, REC8, S Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM... 5 Section F- Supply Air Section Notes Air Foil Fan, Double Width: Code 3= 33A*, 36A*, 40A* Air Foil Fan, Single Width: Code 3= 44B*, 49B* Fan Mounts- 33 Airfoil Double Width Fan: Code 3= 33A, 33A, 33A Fan Mounts- 36 Airfoil Double Width Fan: Code 3= 36A, 36A, 36A3 (Until /04) Fan Mounts- 36 Airfoil Double Width Fan: Code 3= 36A, 36A, 36A3 (/04 & Later) Fan Mounts- 40 Airfoil Double Width Fan: Code 3= 40A, 40A, 40A Fan Mounts- 44 Airfoil Single Width Fan: Code 3= 44B, 44B, 44B Fan Mounts- 49 Airfoil Single Width Fan: Code 3= 49B, 49B, 49B Supply Air Fan Motors... 6, 63 Belt Guards RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

3 Contents, Continued Section F- Supply Air Section, Continued Inverter Bypass Control Box (/06 & Earlier) Motor HP , 66 Motor HP , 68 Motor HP , 70 Inverter Bypass Control Box (/07 thru 5/3) Motor HP Motor HP , 73 Motor HP , 75 Inverter Bypass Control Box (6/3 & Later) Motor HP Motor HP , 78 Motor HP , 80 Inverters Line Reactors Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights MAT, EFT, SAT, DAT, OAT, SD SCB- Split Junction Box (TB5, TB7, TB8, PB0, PB9, PB0, PB9): Code 05= F Section G- Blow-Thru Heat Section for RPE Units Notes Section Mounted Controls- LT, S, REC Option - Blank Compartment: Code 04= Y Diffuser... 9 Option - Hot Water or Steam Coil Heat: Code 04= W, S Hot Water & Steam Heat Coils, Mixing Valves and Actuator (VM)... 9 Option 3- Electric Heat: Code 04= E Heaters, Hi Limit Cutouts, Diffusers... 93, 94 Electric Heat Control Box (5/3 & Earlier) Disconnect Switch DS KW Components... 96, KW Components... 98, 99 Electric Heat Control Box (6/3 & Later) Disconnect Switch DS KW Components...0, KW Components... 03, 04 Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules: 500, 640, 650, 790, 800, 000, 00, 400MBH Heat Exchangers & Vestibules: 500, 000MBH Modulating Burner: Code 34= ****E*, ****R*, ****S* Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* Modulating Burner Controls MicroTech II: Code = *D, *S... 5, 6 MicroTech III: Code = *E, *F, *W... 7 Hi Turn Down Burner Controls MicroTech II: Code = *D, *S... 8, 9 MicroTech III: Code = *E, *F, *W... 0 Gas Train Inlet- Modulating Burner... Gas Train Inlet- Hi Turn Down Burner... Modulating Burner Gas Train Controls GV, GV Hi Turn Down Burner Gas Train Controls GV, GV4, GV5, GV6, GV7, GV Gas Train- Outlet... 5 Gas Train- Modulating Burners w/ Actuator VM... 6 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting... 7, 8 Section H- Blow-Thru Heat Blank Access Section Notes... 9 Access Door Latching Assemblies (All Sections) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

4 Contents, Continued Section I- Blow-Thru Cooling Section Notes Section Mounted Controls- LT6, S6, REC Section J- Final Filter Section Notes... 3 Section Mounted Controls- HL3, PC Filters... 3 Section K- Discharge Plenum Section for RPE Units Notes Section Mounted Controls- DAT, OAT, SD, LT5, S5, REC Isolation Damper w/ Actuator ACT , 36 Section L- Vestibule/Access Section Notes Section Mounted Controls- LT0, S0, REC Vestibule/Access Section Door Hardware & Wall Fan Sump Pump, Vestibule Damper, & Vestibule Heater: Code 43= B*, V* Water Treatment Controls without Water Make-Up Water Treatment Controls with Water Make-Up... 4 Section M- Condenser Section Notes... 4 Sump Water Temp. Sensor SWT, Water Level Switches WL63, WL64, & Sump Heater HTR Fan Deck Assembly... 44, 45 Condenser Coils Compressors... 47, 48 Compressor Components Compressor Mounting Section N- Controls Notes... 5 MicroTech II: Code = *D, *S (3/05 & Earlier) Unit Control Layout Diagram... 5 Main Control Box Power Panel Control/Switch Panel... 6 Condenser Control Box... 6, 63 Compressor Control Box... 64, 65 MicroTech II: Code = *D, *S (4/05 thru /06) Main Control Box Diagram Common Components Supply Fan CB0, and Return Fan CB0 Circuit Breaker... 73, 74 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Compressor MMP- 4 and Contactor M Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MicroTech II: Code = *D, *S (/07 thru /0) Main Control Box Diagram Control Box Component Label Diagram Main Control Box Common Components Supply Fan CB0, and Return Fan CB0 Circuit Breaker & Plugs Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Compressor MMP- 4 and Contactor M Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MicroTech III: Code = *E, *F, *W (/ thru 5/3) Main Control Box Diagram Control Box Component Label Diagram Main Control Box Common Components Supply Fan CB0, and Return Fan CB0 Circuit Breaker... 6 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Compressor MMP- 4 Motor Protector & Contactor M Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB... 6 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

5 Contents, Continued MicroTech III: Code = *E, *F, *W (6/3 & Later) Main Control Box Diagram... 7 Control Box Component Label Diagram... 8 Main Control Box Common Components Supply & Return Fan Contactors, Circuit Breakers, & Fusing Compressor MMP- 4 Motor Protector & Contactor M Condenser Fan Motor Protectors, Contactors, Circuit Breakers, & Fusing Components... 47, 48 Speedtrol Inverters Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C Oil Pressure Box... 5 Section O- Refrigeration Tubing Notes Refrigeration Circuit Diagram... 5 Refrigeration Tubing Layout Diagrams... 53, 54 Refrigeration Tubing Components RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

6 Parts List Revision History Rev. Date Description A- J 07/6 Archived Revs. A- J. K 07/6 Page : Rewrote footnote #. Page - 7: Misc. Coding updates. Page 3, 46 (OLD, 47 (NEW): Rewrote Notes. Page 40 (OLD) 37 (NEW): Moved pg. Updated the TOC. Updated dwg. Added Ref # 6 Adj. Bolt p/n to table. Page 4: Updated mtr. table. Rewrote pg. header. Page 4 (NEW): Added pg. for Shaft Grounded mtrs. Repaginated the form & updated the TOC. Page 43 (OLD) 44 (NEW): Updated Pressure Gauge dwg. & table. Page 44, 45 (OLD) 45, 46 (NEW): Updated Filter p/ns & dwg. Page 53 (OLD) 54 (NEW): Updated dwg. Page 54 (OLD) 55 (NEW): Updated dwg., bubs, & added p/ns. Page 6 (OLD) 6 (NEW): Updated mtr. table. Rewrote pg. header. Page 63 (NEW): Added pg. for Shaft Grounded mtrs. Repaginated the form & updated the TOC. Page 85 (OLD) 87 (NEW): Changed Lamp to Bulb or Fixture. Page 07, 08, (OLD) 09, 0, 3 (NEW): Misc. p/n updates. Added footnotes. Page 4, 7 (OLD) 6, 9 (NEW): Added TB Jumper p/n. Page 5, 8 (OLD) 7, 0 (NEW):Updated TBp/ns. Page 9, 0, 5 (OLD),, 7 (NEW): Updated misc. gas vlv. p/ns. Page 07, 7 (OLD) 09, 9 (NEW): Updated SPS, p/ns. Page 8 (OLD) 30 (NEW): Changed Tennant to Tenant. Page 9 (OLD) 3 (NEW): Updated T p/ns. Page 30 (OLD) 3 (NEW): Changed insure to ensure. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

7 Nomenclature & Unit Layout Unit Model & Serial Number Unit Model Number R PE 076 C S A R = RoofPak Unit Configuration PE = Packaged Evaporative Condensing; Single Zone Unit DE = Packaged Drawthru Evaporative Condensing; Single Zone Unit Nominal Capacity (Tons) 076, 089, 00, 0, 30, 40, 50 Design Vintage Cooling Coil Size S = Small Face Area Coil L = Large Face Area Coil Heat Medium A = Natural Gas E = Electric S = Steam W = Hot Water Y = None (Cooling Only) Unit Serial Number FBO U Plant Identification FBO = Faribault, MN U= Unit Year of Manufacture 04 = = = = = = = 00 = 0 = 0 etc. Serial Number (build sequence) Month of Manufacture 0 = January 0 = February 03 = March 04 = April 05 = May 06 = June 07 = July 08 = August 09 = September 0 = October = November = December RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

8 Nomenclature & Unit Layout Unit Section Locations Typical Section Locations for BlowThru RPE Units B F G I K L M A Typical Section Locations for RDE Units B D E F L M A The Unit Section Layout Diagrams shown above are to be used for reference only. Sections and Component locations vary depending on unit size, age, configuration, and options selected. Refer to the Unit Model Number Complete Section one page after next for section code information. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

9 Nomenclature & Unit Layout Control Component Locations Typical Control Component Locations for RPE Units Condensor Section Discharge Plenum Section Service Section Exhaust Fan Water Treatment (Optional) Heat Section ReturnAir Economizer Water Level Switches (WL63, WL64) Sump Heater (Optional) Sump WaterTempSensor ACT5 (optional) Oil Pressure Box Water Pump Control Box VM (Optional) SD (Optional) Space Heater (Optional) HL (Optional) LT0 (Optional) S0, REC0 (Optional) ACT6 (optional) OAE S OAT LT REC (Optional) RAE (optional) Typical Control Component Locations for RDE Units Condensor Section Heat Section Supply Fan Discharge Plenum Section SV, Service Section Exhaust Fan Water Treatment (Optional) Economizer Return Air Filter Section Water Level Switches (WL63, WL64) Sump Heater (Optional) Sump Water Temp Sensor Oil Pressure Box Water Pump Control Box C9,0 (Optional) LT0 (Optional) S0, REC0 (Optional) SD (Optional) Space Heater (Optional) OAE OAT FS (Optional) LT (Optional) S, REC SD (Optional) The Control Component Layout Diagrams shown above are to be used for reference only. Sections and Component locations vary depending on unit size, age, configuration, and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

10 Nomenclature & Unit Layout Unit Model Number Code Index General Unit Options Primary Unit Model Codes that Pertain: 05, 06, 07, (Mid 0 & Earlier), (Mid 0 & Later) Miscellaneous Controls/Sensors Primary Unit Model Codes that Pertain: 3, 6, 7, 8 Section A= Return/Outside Air/Economizer Section Primary Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 4, 59 (Mid 0 & Later) Section B= Draw-Thru Filter Section Primary Unit Model Codes that Pertain: 5, 33 (Mid 0 & Later) Section C= Blank/Inverter (AFD/VFD) Section Primary Unit Model Codes that Pertain: 4, 5, 6 Section D= Draw-Thru Cooling Section Primary Unit Model Codes that Pertain: 03, 7, 8, 36 Section E= Draw-Thru Spacer/Blank Section Primary Unit Model Codes that Pertain: 6, 30 Section E= Draw-Thru Heat Section for RDE Units Primary Unit Model Codes that Pertain: 04, 30 Section F= Supply Air Section Primary Unit Model Codes that Pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later) Section G= Blow-Thru Heat Section for RPE Units Primary Unit Model Codes that Pertain: 04, 34 Section H= Blow-Thru Heat Blank Access Section Primary Unit Model Codes that Pertain: 34, 38 Section I= Blow-Thru Cooling Coil Section Primary Unit Model Codes that Pertain: 03, 35, 36 Section J= Final Filter Section Primary Unit Model Codes that Pertain: 39 Section K= Discharge Plenum Section Primary Unit Model Codes that Pertain: 08, 40 Section L= Vestibule/Access Section Primary Unit Model Codes that Pertain: 08, 4, 43 Section M= Condenser Section Primary Unit Model Codes that Pertain: 4, 43, 44, 45, 47 Section N= Main Control Panel Primary Unit Model Codes that Pertain: 08, 09,,, 3, 4, 5, 7, 8 Section O= Refrigeration Tubing Primary Unit Model Codes that Pertain: 45, 46 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

11 Nomenclature & Unit Layout Unit Model Number- Complete RPE 076C S A Y EU V 7 AL P LD Y 5 A CH R0 BB FE 44B JEY 50A Y AB S CYYS 4Z083D Code YYYYYY BBBBBB 33A SEY 0890A 00SHC CYYY 4Z083D YYYYYY B B BB 6 EE H A Y Y YY A A A Code 03= Cooling Coil Size S= Small Face Area (076C thru 0C) L= Large Face Area (089C thru 50C) Code 04= Type of Heat Y= None A= Natural Gas Heat E= Electric Heat S= Steam Heat W= Hot Water Heat X= Special Code 05= Split Unit Y= None F= Split at Fan/Heat Section X= Special Code 06= Insulation and Liners =, 3/4# with liners on Doors = ½,.5# with solid liners on Doors & Ceilings 3= ½,.5# with perforated liners in Plenums, solid elsewhere 4= ½,.5# with solid liners on Doors, Ceilings and Floors 5= ½,.5# with perforated liners in Plenums, solid elsewhere (including Floors) 6= ½,.5# With StStl Solid Liners on Doors, Ceiling and Floors X= Special Code 07= Approval Agency Listing Digit : Unit Approval Y= None C= ETL- Canada E= ETL/MEA- USA X= Special Digit : Burner Approval Y= None (Code 04 CANNOT = A) C= ETL- Canada w/ Low Altitude Burner D= ETL- Canada w/ High Altitude Burner M, U= ETL X= Special Code 08= Main Control Box Location P= Standard Location (RPE only) S= Standard Location (RDE only) V= Vestibule X= Special Code 09= Unit Voltage = 08/60/3 9= 30/60/3 7= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across-the-Line PW= Part Winding Start Compressors only XX= Special Code = Field Power Connection Digit : Type of Control A= One Disconnect: Complete Unit C= Two Disconnects: SAF, RAF, & Controls/Balance of Unit B= Two Disconnects: EH/Balance of Unit D= Three Disconnects: EH, SAF, RAF & CB/Balance of Unit P= One Power Block: Complete Unit Q= Two Power Blocks: EH/Balance of Unit R= Two Power Blocks - Fans & Controls/Balance of Unit X= Special Digit : Disconnect Mechanism Location = Internal (Code, Digit = P, Q, R) = Thru-the-door Disconnect (Code, Digit CANNOT= P, Q, R) X= Special Code = Temperature Controls Package MicroTech II Digit : Communication Type L= LonMark B= BACNet w/ MSTP E= BACNet w/ Ethernet S= Standalone (No Communication) X= Special Digit : Control Type D= Discharge Air Temp. Control S= Space or Zone Control X= Special MicroTech III Digit : Communication Type L= LonMark B= BACNet w/ MSTP E= BACNet w/ Ethernet S= Standalone (No Communication) C= BACNet w/ MSTP, VAV Contactor Configurable A= Daikin D3 VRV Gateway X= Special Digit : Control Type E= Discharge Air Temp. Control F= Space or Zone Control W= Discharge Air w/ Space Control XX= Special An "X" located in any position in a code string indicates a special feature. Contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 0 the code structure was changed from a 54 Code Index to a longer more detailed format. A sample 54 Code version is shown above. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

12 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct & Space Sensor 4= Space Sensor X= Special Code 4= Inverters Y= None X= Special Separate Section = SA Fan only w/ Bypass = SA & RA Fans w/ Bypass 4= RA Fan only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan only w/o Bypass 7= SA & RA Fans w/o Bypass 8= RA Fan only w/ Bypass 9= RA Fan only w/o Bypass Code 5= Inverter Vendor Y= None A= ABB G= Graham/Danfoss R= Reliance/Rockwell Q= Schneider S, B= Daikin Applied F= Field Installed Inverter controlled by MicroTech X= Special Code 6= Smoke Detectors Y= None = Return Air Smoke Detector = Supply Air Smoke Detector 3= Supply and Return Air Smoke Detectors X= Special Code 7= Miscellaneous Auxiliary Controls Digit : Type of Control Y= None (may include mechanical enthalpy) C= Differential Enthalpy X= Special Digit : Type of Control Y= None F= Freezestat (Steam, HW Heat) P= Phase Failure G= Ground Fault Protection L= Line Reactors w/ Inverter A= Freezestat & Phase Failure (Steam, HW Heat) B= Freezestat & Ground Fault (Steam, HW Heat) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam, HW Heat) E= Freezestat & Line Reactors (Steam, HW Heat w/ Inverter) H= Phase Failure & Line Reactors (w/ Inverter) J= Freezestat, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) K= Ground Fault, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) Code 7= Miscellaneous Auxiliary Controls Digit, Cont. = UV Lights = UV Lights & Freezestat (Steam, HW Heat) 3= UV Lights & Phase Failure 4= UV Lights & Line Reactors w/ Inverter 5= UV Lights, Freezestat, & Phase Failure (Steam, HW Heat) 6= UV Lights, Freezestat, & Line Reactors (Steam, HW Heat w/ Inverter) 7= UV Lights, Phase Failure & Line Reactors w/ Inverter 8= UV Lights, Freezestat, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) X= Special Code 8= Miscellaneous Controls/Unit Length (three digits) Y, A, S(***)= None ((***)= Air Handler Length [inches]) R, K(***)= Remote Keypad ((***)= Air Handler Length [inches]) M, P(***)= Phone Modem ((***)= Air Handler Length [inches]) W(***)= Wireless Modem ((***)= Air Handler Length [inches]) U(***)= Unit Pwr. Receptacle ((***)= Air Handler Length [inches]) V(***)= K plus Unit Pwr. Receptacle ((***)= Air Handler Length [inches]) Code 9= Return Air Plenum YY= None (No Return Air Section) BY= Bottom Return HY= Back Return LY, SY= Side (opp. drive) Return TY= Top Return BB= Bottom Return w/ Burglar Bars BE= Bottom Return w/ Isolation Damper & Actuator XX= Special Code 0= Outdoor Air Options AE= 00% Outside Air Damper w/ Hood & Actuator BE= 0-30% Outdoor Air w/ Actuator DE= 0-00% Economizer w/ Barometric Exhaust Damper w/ Actuator EE= 0-00% Economizer w/ Powered Closure Exhaust Damper w/ Actuator HE= 0-00% Economizer w/ Prop Exhaust Damper w/ Actuator FE= same as DE plus Design Flow GE= same as EE plus Design Flow JE= same as HE plus Design Flow XX= Special Code = Return Air Fan YYYY= None Digit - 3: Wheel Type 44B= 44 Airfoil (AFSW) Digit 4: Isolator type = Rubber-in-Shear (RIS) = Spring 3= Spring w/ Seismic Restraints RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

13 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code = Return Air Fan Motor YYY= None XXX= Special Digit : Motor Size H= 3.0 HP N= 0.0 HP R= 40.0 HP J= 5.0 HP M= 5.0 HP S= 50.0 HP K= 7.5 HP P= 5.0 HP T= 60.0 HP L= 0.0 HP Q= 30.0 HP (Prop Exhaust option is always J [5.0 HP]) Digit : Motor Type E= High Efficiency ODP F= High Efficiency VAV H= High Efficiency Totally-Enclosed J= Premium Efficiency ODP K= Premium Efficiency Totally-Enclosed Digit 3: Motor Options Y= None S= With With Shaft Grounding Kit Code 3= Return Air Fan Drive Selection (Mid 0 & Earlier) YYYYY= No Return Air Fan XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 3= Miscellaneous Electrical Options (Mid 0 & Later) Digit : UV Lights Y= None U= UV Lights X= Special Digit : Plenum Lights Y= None P= Plenum Lights X= Special Digit 3: Energy Recovery Inverter Y= None A= ABB ACH550 B= Daikin Applied Q= Schneider X= Special Digit 4: Not an RPE/RDE Code Item Y= None F= Unit powered Receptacle X= Special Digit 5: Intelligent Equipment Y= None A= IE Control X= Special Code 4= Exhaust Fans Y= None = Exhaust Fans w/ Hood 3= 3 Exhaust Fans w/ Hood X= Special Code 5= Draw-Thru Filter/Air Blender Section Digit : Section Type Y= None A= Angular 4 Section G= 4 Angular 4 Section D= Angular w/ LO CFM Blender 48/4 Section (Mid 0 & Earlier) D= Blank 4 Inch Section (Mid 0 & Later) E= Angular w/ HI CFM Blender 48/4 Section (Mid 0 & Earlier) E= Blank 48 Inch Section (Mid 0 & Later) F= Flat 4 Section H= Flat w/ HI CFM Blender 48/4 Section L= Large Staggered 48/4 Section S= Staggered 48 Section V= Staggered w/ HI CFM Blender 48/48 Section B= Blank 4 Section C= Blank 48 Section X= Special Digit : Filter Type Y= No Filters factory provided B= 30% Efficient, Throwaway C= 30% Efficient, Throwaway w/ Intersept H= 85% Efficient, Throwaway D= 65% Efficient Cartridge w/ Prefilters E= 95% Efficient Cartridge w/ Prefilters G= 95% Efficient Cartridge w/ Intersept & Prefilters X= Special Code 6= Blank Draw-thru Section Y= None E= Blank 4 Section F, S= Blank 48 Section X= Special Code 7= Draw-Thru Unit Coil Section YYYY= None CYYY= Cooling Coil Section w/ galvanized steel sloped Drain Pan CYYS= Cooling Coil Section w/ stainless steel sloped Drain Pan XXXX= Special Code 8= Draw-Thru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D H= Hi-F Aluminum Fin (5Z**** only) C= Hi-F Copper Fin J= Hi-F Aluminum Fin D= Lanced Aluminum 4Z= Type 4EZ 5Z= Type 5EZ XXXXXX= Special 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch Code 9= Not an RPE/RDE Code Item YYYYYY= None RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

14 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 30= Draw-Thru Spacer Section YYYYYY= No Heating Section EEEEEE= Blank 4 Section BBBBBB, FFFFFF= Blank 48 Section XXXXXX= Special Code 30= Blow-Thru Heating Section (RDE only) Hydronic Heat W J 3 E E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. = Way Steam Valve 3= 3 Way HW Valve S= 5JA060H (6FPI, Row Steam Coil) S= 5JA0H (FPI, Row Steam Coil) S3= 5JA060C (6FPI, Row Steam Coil) S4= 5JA0C (FPI, Row Steam Coil) W= 5WH090H (9FPI, Row HW Coil) W= 5WS090C (9FPI, Row HW Coil) XXXXXX= Special Code 30= Draw-Thru Heating Section (RDE only) Electric Heat E0 4 Y 4= 4 Stages 6= 6 Stages E= Electric Actuator Y= None E00= 0 KW Heater E60= 60 KW Heater E040= 40 KW Heater E00= 00 KW Heater E060= 60 KW Heater E40= 40 KW Heater E080= 80 KW Heater E80= 80 KW Heater E00= 00 KW Heater E30= 30 KW Heater E0= 0 KW Heater XXXXXX= Special Code 3= Supply Air Fan XXXX= Special Digit - 3: Wheel Type 33A= 33 Airfoil Double Width (RPE only) 33F= 33 Forward Curved, LP (RPE only) 33M= 33 Forward Curved, MP (RPE only) 36A= 36 Airfoil Double Width (RPE only) 36F= 36 Forward Curved, LP (RPE only) 36M= 36 Forward Curved, MP (RPE only) 40A= 40 Airfoil Double Width (RPE only) 40F= 40 Forward Curved, LP (RPE only) 40M= 40 Forward Curved, MP (RPE only) 44B= 44 Airfoil Single Width (RDE only) 49B= 49 Airfoil Single Width (RDE only) Digit 4: Isolator type = Rubber-in-Shear (RIS) = Spring 3= Spring w/ Seismic Restraints Code 3= Supply Air Fan Motor XXX= Special Digit : Motor Size J= 5.0 HP Q= 30.0 HP K= 7.5 HP R= 40.0 HP L= 0.0 HP S= 50.0 HP M= 5.0 HP T= 60.0 HP N= 0.0 HP U= 75.0 HP P= 5.0 HP Digit : Motor Type E= High Efficiency ODP F= High Efficiency VAV H= High Efficiency Totally-Enclosed J= Premium Efficiency ODP K= Premium Efficiency Totally-Enclosed Digit 3: Motor Options Y= None S= With With Shaft Grounding Kit Code 33= Supply Air Fan Drive Selection (Mid 0 & Earlier) XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 33= Miscellaneous Options (Mid 0 & Later) Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in Draw-Thru section B= Magnehelic/Differential Filter Gauge in Blow-Thru section C= Magnehelic/Differential Filter Gauge in Draw-Thru & Blow-Thru sections Digit : California Title 4 Y= None F= Economizer with FDD Digit 3: Ebtron Air Flow Measuring Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Not an RPE/RDE Code Item Y= None Code 34= Blow-Thru Spacer Section YYYYYY= No section, cooling only BBBBBB= Blank 48 section, no heat, cooling only (RPE only) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

15 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 34= Blow-Thru Gas Heat Section (RPE only) 00 S H C A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position D= Extra High CFM Baffle Position Y= None E= Modulating 3: Burner, Maximum gas pressure= 0.5 psi R= Modulating Burner w/ H.P. Regulator Range= - 3 psi S= Modulating Burner w/ H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner 0: T= Hi Turn Down Burner 0: w/ H.P. Regulator Range= - 3 psi U= Hi Turn Down Burner 0: w/ H.P. Regulator Range= 5-0 psi A= Stainless Steel Primary, Aluminized Steel Secondary Heat Exchanger S= Stainless Steel Heat Exchanger 050= 500 MBH 00= 000 MBH 064= 640 MBH 0= 00 MBH 065= 650 MBH 40= 400 MBH 079= 790 MBH 50= 500 MBH 080= 800 MBH 00= 000 MBH XXXXXX= Special Code 34= Blow-Thru Steam/Hot Water Heat Section (RPE only) W J 3 E = Way Steam Valve 3= 3 Way HW Valve Y= No Valve E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. E= Electric Actuator S= 5JA060H (6FPI, Row 5JA Steam Coil) S= 5JA0H (FPI, Row 5JA Steam Coil) S3= 5JA060C (6FPI, Row 5JA Steam Coil) S4= 5JA0C (FPI, Row 5JA Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5 WS HW Coil) XXXXXX= Special Code 34= Blow-Thru Electric Heat Section (RPE only) E00 Y None = Stage 4= 4 Stages = Stages 6= 6 Stages E00= 0 KW Heater E60= 60 KW Heater E040= 40 KW Heater E00= 00 KW Heater E060= 60 KW Heater E40= 40 KW Heater E080= 80 KW Heater E80= 80 KW Heater E00= 00 KW Heater E30= 30 KW Heater E0= 0 KW Heater Code 35= Blow-Thru Unit Coil Section YYYY= None CYYY= Cooling Coil Section w/ galvanized steel sloped Drain Pan CYYS= Cooling Coil Section w/ stainless steel sloped Drain Pan XXXX= Special Code 36= Cooling Coil (RPE only) YYYYYY= No Cooling Coil 4Z 08 3 D 4Z= Type 4EZ 5Z= Type 5EZ XXXXXX= Special 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch Code 37= Not an RPE/RDE Code Item YYYYYY= None H= Aluminum Fin D= Lanced Aluminum C= Copper Fin Code 38= Blow-Thru Blank/Attenuator Section Y= No section G= With 36 Std. Straight Attenuator K= With 36 Std. Straight Attenuator w/ Tedlar Coating H= With 60 Std. Straight Attenuator L= With 60 Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating B, F= Blank 48 Section E= Blank 4 Section RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

16 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 39= Final Filter Section (RPE only) Y= No section A= Flat filter section, 95% cartridge, 4/4 section J= Flat filter section, 95% cartridge, 4 section B= Staggered filter section, 95% cartridge, 4/48 section K= Staggered filter section, 95% cartridge, 48 section E= Flat filter section, 95% cartridge w/ Intersept, 4/4 section L= Flat filter section, 95% cartridge w/ Intersept, 4 section W= Large Staggered section, 95% cartridge 48/4 section G= Flat filter section, 95% HEPA cartridge, 4/48 section N= Flat filter section, 95% HEPA cartridge, 48 section H= Flat filter section, 95% cartridge, 48/48 section C, Q= Blank 4/4 section D, R= Blank 4/48 section S= Blank 4 section T= Blank 48 section X= Special Code 40= Discharge Air Plenum Digit : Discharge Air Location B, G= Bottom Discharge H, L, S= LH Side (opposite Drive side) R= RH Side (Drive side) T= Top Discharge X= Special Digit : Options Y= None B= Burglar Bars (Code 40, Digit = B) E= Bottom Discharge w/ Isolation Damper & Actuator (Code 40, Digit = B) X= Special Code 4= Vestibule Compartment = 4/48 Section, out of airstream with Light X= Special Code 4= Compressor Capacity Control 4= 4 steps 6= 6 steps 8= 8 steps X= Special Code 43= Condenser Options Digit : Section Type E= Evaporative Condenser S= Evaporative Condenser w/ Sump Heater V= Evaporative Condenser w/ Heater in Vestibule B= Evaporative Condenser options w/ Sump Heater & Heater in Vestibule X= Special Digit : Water Treatment/Compressor Conduit Type Y= Bleed Off Only- Flex Conduit D= Bleed Off Only- Liquid Tight Conduit E= Dolphin, w/o Corr. Coupon, w/o Comm- Flex Conduit F= Dolphin, w/o Corr. Coupon, w/o Comm- Liquid Conduit H= Dolphin, w/o Corr. Coupon, w/ Comm- Flex Conduit J= Dolphin, w/o Corr. Coupon, w/ Comm- Liquid Conduit K= Dolphin, w/ Corr. Coupon, w/o Comm- Flex Conduit L= Dolphin, w/ Corr. Coupon, w/o Comm- Liquid Conduit M= Dolphin, w/ Corr. Coupon, w/ Comm- Flex Conduit N= Dolphin, w/ Corr. Coupon, w/ Comm- Liquid Conduit X= Special Code 44= Compressor Type H= Semi Hermetic Discus, R K= Semi Hermetic Discus, R407C Code 45= Compressor Isolation = Resilient Rubber-In-Shear (RIS) = Spring Isolation w/ Vibration Eliminators on piping X= Special Code 46= Piping Options Y= None = Hot Gas Bypass, Circuit # = Hot Gas Bypass, Circuits & 3= Replaceable Filter Drier Core 4= Hot Gas Bypass, Circuit # & Replaceable Filter Drier Core 5= Hot Gas Bypass, Circuits #, & Replaceable Filter Drier Core X= Special Code 47= Low Ambient Operation A= Speedtrol w/ ABB VFD B, S= Speedtrol w/ Daikin Applied VFD G= Speedtrol w/ Graham/Danfoss VFD Q= Speedtrol w/ Schneider VFD R= Speedtrol w/ Reliance VFD X= Special Code 48= IBC Seismic Construction/Compressor Power Factor Capacitors Y= None P= Power Factor Capacitors I= Seismic Construction X= Special Code 49= Fan Section Options Y= None A= SA Fan Belt Guard B= SA Fan Section Light C= SA Fan Belt Guard & SA Fan Section Light D= SA & RA Fan Belt Guard E= SA & RA Fan Section Light F= SA & RA Fan Belt Guard & Fan Section Light X= Special Code 50= Miscellaneous (Mid 0 & Earlier) YY= None XX= Special Code 50= Blender Section (Mid 0 & Later) Y= None L= Low CFM Blender H= High CFM Blender E= Blank 4 section F= Blank 48 section X= Special Code 5= Packaging (Mid 0 & Earlier) = Steel Skid = Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

17 Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 5= Draw-Thru Pre Heat Section (Mid 0 & Later) W J 3 E E= Electric Actuator Y= Less Actuator Code 58= Return Air Fan Drive Selection (Mid 0 & Later) YYYYY= No Return Air Fan XXXXX= Special A = Way Steam Valve 3= 3 Way HW Valve Y= No Valve E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. S= 5JA060H (6FPI, Row 5JA Steam Coil) S= 5JA0H (FPI, Row 5JA Steam Coil) S3= 5JA060C (6FPI, Row 5JA Steam Coil) S4= 5JA0C (FPI, Row 5JA Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5 WS HW Coil) EEEEEE= Blank 4 section FFFFFF= Blank 48 section XXXXXX= Special Code 5= Parts Warranty (Mid 0 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 5= Drain Pan/Humidifier Section (Mid 0 & Later) YY= None DY= Drain Pan only 48 section DH= Drain Pan & Humidifier 48 section Code 53= Compressor Warranty (Mid 0 & Earlier) A= Standard One Year Compressor Q= Extended Four Year Compressor, Five Year Total Z= Special Code 53= Custom Unit Specifications YY= None XX= Special Code 54= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 54= Final Filter Section (RPE only) (Mid 0 & Earlier) Y= None A= Flat Section, 95% Cartridge Filters, 4/4 Section B= Staggered Section, 95% Cartridge Filters, 4/48 Section C= Blank 4/4 Section D= Blank 4/48 Section E= Flat Section, 95% Cartridge Filters w/ Intersept, 4/4 Section F= Staggered Section, 95% Cartridge Filters w/ Intersept, 4/48 Section X= Special Codes 54-57= Not RPE/RDE Code Items (Mid 0 & Later) YYYYYYYY= None Required RPM Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection (Mid 0 & Later) XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Miscellaneous (Mid 0 & Later) YY= None XX= Special Code 6= Packaging (Mid 0 & Later) = Steel Skid = Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate Code 6= Parts Warranty (Mid 0 & Later) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty (Mid 0 & Later) A= Standard One Year Compressor Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Factory Code (Mid 0 & Later) 077C= Unit Configurator Code 66= Drain Connection (Mid 0 & Later) R= RH (Drive side) L= LH (opposite drive side) Code 67= Not an RPE/RDE Code Item (Mid 0 & Later) Y= None Code 68= Short Circuit Current Rating (Mid 0 & Later) 0= 0 SCCR YY= None XX= Special RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

18 Nomenclature & Unit Layout Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors- Economizer Dampers Economizer Section ACT5 Actuator Motor- Discharge Isolation Damper Discharge Section ACT6 Actuator Motor- Return Air Isolation Damper Return Air Section ACT7 Actuator Motor- Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor- Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors- Exhaust Dampers Return Air Section ACT6 Actuator Motor- Sump Fill Vestibule Section ACT6 Actuator Motor- Sump Blow Down Vestibule Section ACT63 Actuator Motor- Auto System Drain Vestibule Section ACT64 Actuator Motor- Sump Purge Vestibule Section AFD0 Adjustable Frequency Drive- Supply Fan AFD/Supply Fan Sect. AFD Adjustable Frequency Drive- Condenser Fans Main/Cond. Control Box AFD0 Adjustable Frequency Drive- Return/Exhaust Fan AFD/Supply/Exhaust Sect. AS Blower Air Switch Gas Heat Section BM Burner Blower Motor Gas Heat Section C- C8 Power Factor Capacitors- Compressors Condenser Section C0 Power Factor Capacitors- Supply Fan Supply Air Section C Capacitor- SpeedTrol (Circuit #) Condenser Bulkhead C0 Power Factor Capacitors- Return Fan Return Air Section C Capacitor- SpeedTrol (Circuit #) Condenser Bulkhead CB0 Circuit Breaker- Supply Fan Main Control Box CB Circuit Breaker- Condenser Fans Main/Cond. Control Box CB0 Circuit Breaker- Return Fan Main Control Box CCB, Compressor Control Boards (MicroTech II) Main/Cond. Control Box COMPR- 4 Compressors Condenser Section CS, Control Switches- Refrigerant Circuits Main/Cond. Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor- Left Hand Return Section DFRH Design Flow Sensor- Right Hand Return Section DHL Duct High Limit Main Control Box Dolphin T Transformer, Sump Vestibule Dolphin T Transformer, Make Up Water Vestibule Dolphin CTL Conductivity Control Vestibule DS Disconnect- Total Unit or Condenser/Heat Main Control Box DS Disconnect- SAF/RAF/Controls Main Control Box DS3 Disconnect- Electric Heat Electric Heat Section DS6 Disconnect- Factory Powered Outlet Condenser Section EFT Entering Air Temperature Sensor Supply Fan Section EHB Staged Electric Heat Board (MicroTech II) Main Control Box EXPA- D Expansion Boards (MicroTech III) Main Control Box F, A Fuses- Control Circuit, T Primary Main Control Box FC Fuse- Control Circuit, T Secondary Main Control Box F Fuse- Control Circuit, T Primary Main Control Box F3 Fuse- Burner Motor Main Control Box F6A, B Fuses- T6 Transformer, Primary Condenser Section F6C Fuse- T6 Transformer, Secondary Condenser Section FB9, 0 Fuseblocks- Supply Fan Main/Cond. Control Box FB,,, 3, FS Fuseblocks- SpeedTrol Main/Cond. Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

19 Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location FB9, 0 Fuseblocks- Exhaust/Return Fan Main/Cond. Control Box FB3-40 Fuseblocks- Electric Heat (Top Bank) Electric Heat Section FB4-50 Fuseblocks- Electric Heat (Bottom Bank) Electric Heat Section FB64 Fuseblock- Condenser Water Pump Main/Cond. Control Box FB65 Fuseblock- Condenser Sump Heater Main/Cond. Control Box FD Flame Detector Gas Heat Section FLC Fan Limit Control Gas Heat Section FP, Frost Protection- Refrigeration Circuits Coil Section, Cool FS, Freezestats Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Section GCB Generic Condenser Board (MicroTech II) Main Control Box GFS/GFR Ground Fault Sensor/Relay Main Control Box GFS/GFR Ground Fault Sensor/Relay Main Control Box GFS4/GFR4 Ground Fault Sensor/Relay Condenser Control Box GRD Ground All Control Boxes GV Gas Valve- Pilot Gas Heat Section GV Gas Valve- Main/Safety Gas Heat Section GV3 Gas Valve- Redundant/Safety Gas Heat Section GV4-8 Gas Valves- Main, Hi-Turn Down Gas Heat Section HL- 0 High Limits- Elec. Heaters, Power (Top Bank) Electric Heat Section HL- 0 High Limits- Elec. Heaters, Power (Bottom Bank) Electric Heat Section HL High Limit- Gas Heat (Prefilters) Supply Air Section HL3 High Limit- Gas Heat (Final Filter) Final Filter Section HL3-40 High Limits- Elec. Heaters, Control (Top Bank) Electric Heat Section HL4-50 High Limits- Elec. Heaters, Control (Bottom Bank) Electric Heat Section HP- 4 High Pressure Controls- Refrigerant On Compressors HP5 High Pressure Control- Gas Gas Heat Section HS Heat Switch- Electric Shutdown Main Control Box HS3 Heat Switch- Electric Heat Deadfront Interlock Electric Heat Section HTR- 4 Compressor Crankcase Heaters On Compressors HTR65 Heater- Sump Condenser Section HTR66 Heater- Vestibule Condenser Vestibule IT Ignition Transformer Gas Heat Section LP, Low Pressure Controls- Refrigerant On Compressors LP5 Low Pressure Control- Gas Gas Heat Section LR0 Line Reactor- Supply Fan Inverter Bypass CB LR, Line Reactors- SpeedTrol Condenser Section LR0 Line Reactor- Return/Exhaust Fan Inverter Bypass/Main CB LS, Limit Switches- Low Fire/High Fire Gas Heat Section LT0 Light- Supply Fan Supply Air Section LT Light- Return Fan Return Air Section LT Light- Heat Section Heat Section LT3 Light- Filter Section Filter Section LT4 Light- Final Filter Section Final Filter Section LT5 Light- Discharge Section Discharge Section LT6 Light- Blow-Thru Coil Section Blow-Thru Coil Section LT7 Light- Evaporator Coil Section Evaporator Coil Section LT8 Light- Preheat Section Preheat Section LT9 Light- Blank Section Blank Section Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

20 Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location LT0 Light- Blank Compartment Blank Compartment LT Light- Draw-Thru Coil Section Draw-Thru Coil Section LT Light- Condenser Section Condenser Section LT3 Light- Vestibule Condenser Vestibule M- 4 Contactors- Compressors Main/Cond. Control Box M0 Contactor- Supply Fan Main Control Box M- 8 Contactors- Condenser Fans, Circuit # Main/Cond. Control Box M0 Contactor- Return Fan Main Control Box M- 8 Contactors- Condenser Fans, Circuit # Main/Cond. Control Box M9 Contactor- Burner Motor Gas Heat Section M30 Contactor- Supply Fan Inverter Bypass Inverter Bypass Box M3-39 Contactors- Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor- Return Fan Inverter Bypass Inverter Bypass Box M4-50 Contactors- Elec. Heaters (Bottom Bank) Electric Heat Section M64 Contactor- Sump Pump Main/Cond. Control Box M65 Contactor- Sump Heater Main/Cond. Control Box MCB Microprocessor Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes MMP- 4 Manual Motor Protectors- Compressors Main/Cond. Control Box MMP0 Manual Motor Protector- Supply Fan Main Control Box MMP- 8 Manual Motor Protectors- Condenser Fans Ckt. Main/Cond. Control Box MMP0 Manual Motor Protector- Return Fan Main Control Box MMP- 8 Manual Motor Protectors- Condenser Fans Ckt. Main/Cond. Control Box MMP30 Manual Motor Protector- Supply Fan Inverter Bypass Inverter Bypass Box MMP40 Manual Motor Protector- Return Fan Inverter Bypass Inverter Bypass Box MMP5-53 Manual Motor Protectors- Prop Exhaust Fan Motors Return Air Section MMP64 Manual Motor Protector- Sump Pump Main/Cond. Control Box MP- 4 Motor Protectors- Compressors On Compressors OAE Outside Air Enthalpy Control Economizer Section OAT Outside Air Temperature Sensor Discharge Bulkhead OP- 4 Oil Pressure Controls- Compressors Condenser Section PB, Powerblocks- Power Distribution Main Control Box PB3 Powerblock- Electric Heat Electric Heat Section PB4 Powerblock- Condenser Condenser Control Box PB9, 0 Powerblocks- Supply Fan Unit Split Junction Box PB, Powerblocks- Power Distribution Main Control Box PB9, 0 Powerblocks- Return/Exhaust Fan Unit Split Junction Box PC5 Pressure Control- Clogged Filter Pre Filter Section PC6 Pressure Control- Clogged Final Filter Final Filter Section PC7 Pressure Control- Proof of Airflow Supply Air Filter PC8 Pressure Control- Minimum Airflow Coil Section, Cool PS- 3 Pumpdown Switches- Refrigerant Circuits Main/Cond. Control Box PT,,, Pressure Transducers- SpeedTrol Pressure/Cond. Section PVM, Phase Voltage Monitors Main Control Box PVM4 Phase Voltage Monitor- Condenser Condenser Control Box R, Relays- High Pressure Reset Main/Cond. Control Box R3, 4 Relays- Hi Pressure Delay Main/Cond. Control Box R5-8 Relays- Compressor, Safety/Cool Fail Main/Cond. Control Box R9, 0 Relays- Compressor Lockout Main/Cond. Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

21 Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location R, Relays- SpeedTrol Fan Cycling (MicroTech II) Main/Cond. Control Box R, 7 Relays- SpeedTrol Inverter Enable Main/Cond./Pressure Box R- 4 Relays- FanTrol Condenser Fan Cycling Main Control Box R0 Relay- Gas, Steam, Hot Water Heat Gas Section/Main CB R, Relays- Gas Heat, High Turndown Gas Heat Section R3 Relay- Gas/Electric Heat Gas Sect./Elec. Ht. CB R4 Relay- Gas Heat Alarm Main Control Box R5 Relay- Gas Heat Start, Supply Fan Inverter Main Control Box R6 Relay- Isol./Exh. Dampers Open/Close Main Control Box R8 Relay- Isolation Damper Safety Main Control Box R9 Relay- Remote Fire Alarm Main Control Box R30 Relay- Cool Valve w/ Face & Bypass Main Control Box R45 Relay- UV Lights Main Control Box R46, 47 Relays- Supply Fan Inverter increase/decrease Main Control Box R48, 49 Relays- Return Fan Inverter increase/decrease Main Control Box R56 Relay- Water Pipe Heater Main/Cond. Control Box R57 Relay- Sump Fill Main Control Box R6 Relay- Smoke Detector, Discharge Air Main Control Box R6, 63, 65 Relays- Specials Main Control Box R64 Relay- Sump Pump Main/Cond. Control Box R66 Relay- RA Smoke Detector Main Control Box R67 Relay- Supply Fan Enable Main Control Box R68 Relay- Return Fan Enable Main Control Box R69 Relay- Inverter Bypass VAV Box Interlock Main Control Box R70-79 Relays- Specials Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle- Main Box Main Control Box REC Receptacle- Condenser Box Condenser Section REC3 Receptacle- Field Power, 5V Discharge Bulkhead REC0-3 Receptacles- Cabinet Sections Cabinet Sections S Switch- System On/Off Main Control Box S3 Switch- Furnace On/Off Gas Heat Section S4 Switch- Inverter Bypass On/Off Main Control Box S7 Switch- Local On/Off/Auto to Controller Main Control Box S0-3 Switches- Cabinet Section Lights Cabinet Sections S40-45 Switches- Door Interlock, UV Lights Cabinet Sections SD Smoke Detector- Supply Air Discharge Section SD Smoke Detector- Return Air Return Air Section SHS Space Humidity Sensor Return Section/Field Inst. SPS, Static Pressure Sensors- Duct or Building Main Control Box SR- 3 Sequence Relays- Electric Heat Electric Heat Section SV, Solenoid Valves- Liquid Condenser Section SV5, 6 Solenoid Valves- Hot Gas Bypass Condenser Section SV6, 6 Solenoid Valves- Sump Fill Main/Cond. Control Box SV63 Solenoid Valve- Sump Drain Main/Cond. Control Box SWT Sensor- Sump Water Temperature Condenser Section T Transformer- Main Control, 5V Main Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

22 Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location T Transformer- Control Input, 5/4V Main Control Box T3 Transformer- Control Output, 5/4V Main Control Box T4 Transformer- Exhaust Damper Actuator, 5/V Main Control Box T5 Transformer- Electric Heat Electric Heat Section T6 Transformer- Unit Supplied, 5V Condenser Section T9 Transformer- Refrigerant Circuit, 4V Main Control Box TB, 3 Terminal Blocks- Factory Main Control Box TB, 4 Terminal Blocks- Field Main/Cond. Control Box TB5, 6 Terminal Blocks Condenser Section TB7, 8 Terminal Blocks- 5V Convenience Outlet Main/Cond. Control Box TB Terminal Block- Heat Gas Sect./Elec. Ht. CB TB3 Terminal Block- Oil Pressure Box Condenser Vestibule TB5-8 Terminal Blocks- Split Unit Junction Box Unit Split Junction Box TC- 4 Temperature Controls- FanTrol Condenser Control Box TC56 Temperature Control- Water Pipe Heater Condenser Vestibule TC66 Temperature Control- Vestibule Exhaust Fan Condenser Vestibule TD, Time Delays- Compressor Lockout Main/Cond. Control Box TD3, 4 Time Delays- High Pressure Main/Cond. Control Box TD0 Time Delay- Hi-Turn Down Burner Gas Heat Section TD, Time Delays- Low Ambient Main/Cond. Control Box TD0 Time Delay- Return Air Fan Main Control Box TD64 Time Delay- Oil Pressure Condenser Section TR, Transducer- Pressure Main Control Box U, Unloaders- Compressors On Compressors UV Ultra Violet Lights Coil/Discharge Section VFD0 Adjustable Frequency Drive- Supply Fan Dr-Thru/Supply Fan Sect. VFD, Adjustable Frequency Drives- SpeedTrol Condenser Section VFD0 Adjustable Frequency Drive- Return/Exhaust Fan Dr-Thru/Ret/Exh Fan Sect. VM Valve Motor- Heating Heating Section VM5 Valve Motor- Cooling Coil Section, Cool VV Vent Valve Gas Heat Section WL63 Water Level- Sump Fill Condenser Section WL64 Water Level- Sump Low Water Condenser Section ZNT Zone Temperature Sensor- Control Field Installed Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

23 Section A- Outdoor Air/Return Air/Economizer Section Notes Primary Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 4, 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09,, 6, 7, 49 Codes 9 and 0 determine the base section. Code 9 refers to the Return Air Plenum, and determines if the unit has bottom return air (Code 9= B*), back return air (Code 9= H*), or side return air (Code 9= S*). A Return Air Plenum is required for any outdoor air application with an Economizer (Code 0= D*, E*, F*, G*, H*, J*). The only case in which a Plenum is NOT required is when a 00% Outdoor Air Damper and Hood are ordered (Code 0= AE). Codes,, 3 (Mid 0 & Earlier), AND/OR 58 (Mid 0 & Later) determine the Return Air Fan, Motor, and Drive components. These codes only pertain to units with a 0-00% Economizer (Code 0= D*, E*, F*, G*, H*, J*). Return Air Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification. Fan Motors range from 3-60 horsepower, and the Fan Wheel is a 44 Single Width Airfoil (AFSW). Code 4 indicates whether the unit is equipped with two or three Exhaust Fans and Exhaust Hoods. Code 06 determines the panels used in final cabinet assembly. For sheet metal components that make up the Outdoor/Return Air/Economizer Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Code, the control system, comes into play when an Economizer is present by modulating airflow through the unit. If Code 6=, 3 a Smoke Detector (SD) is present in the Return Air Section. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. See the Unit Code Index section to determine which options were specified. Code 49 determines if the Return Air Fan has a Fan Belt Guard and/or a Cabinet Light. If Code 49= D, the Return Air Section has a Fan Belt Guard. If Code 49= E the Return Air Section has a Cabinet Light. Code 49= F indicates both options have been selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

24 Section A- Outdoor Air/Return Air/Economizer Section 00% Outside Air Damper with Hood & No Return Air Plenum Code 0= AE AND Code 9= YY 9 Air Flow Ref. Part Part Qty. No. Description Number 00 Damper Assy Liner Panel- Hood Side Panel- Hood Side Panel- Hood Top Louver Channel- Support Channel- Support This assembly includes the Damper and Linkage, but NO Actuator. For Damper & Actuator components refer to the following page. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

25 Section A- Outdoor Air/Return Air/Economizer Section 00% Outside Air Damper Code 0= AE AND Code 9= YY (/07 & Earlier) 4 Motorized Linkage Detail Ref. Part Part Qty. No. Description Number 4 Shaft- Linkage Adapter Plate- CrankArm Blade- Damper Grille Stop/Anti- Rotate- Damper Support- Damper Motor Crank Arm- Damper Ball Joint- Damper Actuator- Motorized (ACT3) Bushing- Linkage Bar, Nylon Bushing- Damper Blade, Nylon Gasket- Vinyl Gasket- Vinyl Plug- Damper End Plug- Damper End Plug- Damper End For units built /08 & Later contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

26 Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Section with Barometric Exhaust Damper & Return Air Fan Code 0= DE, EE, FE, GE Bottom Return (Code 9= B*) shown Ref. Part Part Qty. No. Description Number 00 Economizer Damper (Code 0= DE, EE, FE, GE) 60 Exhaust Damper Assy Powered (Code 0= EE, GE) Barometric (Code 0= DE, FE) Fan Guard Fan Guard Fan Guard Contact Daikin Applied with model and serial number information so that the correct Damper Assembly can be identified. Economizer detail follows one page after next. Exhaust Damper detail follows five pages after next. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

27 Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 0= HE, JE AND Code 4=, 3 Fan Guard Fan Arrangement w/ Hood Shown (Code 4= 3) Ref. Part Part Qty. No. Description Number N/S Economizer Damper w/ Actuator (Code 0= HE, JE) 4 Hood- Prop Exhaust 830 Grille- Prop Exhaust Fan Guard 840 Grill- Fan Guard Exhaust Fan Assembly 3 08/30/ Exhaust Fan Assembly N/S= Not Shown on diagram. Quantity is PER fan. Contact Daikin Applied with model and serial number information so that the correct Damper Assembly can be identified. Economizer detail follows on the next two pages. 3 Exhaust Fan detail follows four pages after next. 4 Quantity may be two (Code 4= ) OR three (Code 4= 3). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

28 Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Damper w/ Actuator ACT3- Diagrams Code 0= DE, EE, FE, GE, HE, JE Detail (/ & Later) Detail (/ & Earlier) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

29 Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Damper w/ Actuator ACT3- Components Code 0= DE, EE, FE, GE, HE, JE Ref. Part Part Qty. No. Description Number 4 Shaft Assembly Plate- Crank Arm / & Earlier Shaft Assy.- Damper Linkage / & Later Shaft- Linkage Channel- Actuator Mount / & Later Blade- Damper Stop/Anti-Rotate- Damper Support- Damper Motor / & Earlier Bar- Linkage Drive Tab- Linkage Bar Crank Arm- Damper / & Earlier Ball Joint- Damper Actuator, ACT3, 0V / & Earlier Actuator, ACT3, 4V / & Later Bushing- Linkage Bar Bushing- Damper Blade Gasket- Vinyl Gasket- Vinyl End Plug- Damper End Plug- Damper End Plug- Damper Bearing- Flange / & Later Nut N/S Gasket- Neoprene N/S= Not Shown on Diagram. Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

30 Section A- Outdoor Air/Return Air/Economizer Section California Title 4 Assembly Code 33 (Mid 0 & Later) = *F*** Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch Bracket, Mounting Switch Switch, Push Button SPDT Bushing, Conduit 3630 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 30

31 Section A- Outdoor Air/Return Air/Economizer Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE Diagrams 0/ & Earlier ACT6 Actuator Detail / & Later ACT6 Actuator Detail RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

32 Section A- Outdoor Air/Return Air/Economizer Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE Components Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized / & Earlier Isolation Damper Assy- Motorized / & Later Motor Mount Assembly / & Earlier Motor Mount Assembly / & Later Blade Assembly- Return, Angle- Linkage Angle- Blade Shaft- Damper Blade Shaft- Linkage Bearing, Flange, Nylon Actuator- Motorized- SPDT (ACT6), 0V / & Earlier Actuator- Motorized- SPDT (ACT6), 4V / & Later Crank Arm- Damper / & Earlier Crank Arm- Damper / & Later Ball Joint Bearing- Sleeve Gasket, Vinyl Bearing- Sleeve / & Later RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

33 Section A- Outdoor Air/Return Air/Economizer Section Prop Exhaust Fan & Damper Code 0= HE, JE AND Code 4=, B 6C A 6B 6H 6D 6E 6F 6G 6A Lube Line Detail 53 Control Box (see one page after next) 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD0 Inverter see charts on following page A Resistor- Inverter B Jumper- Inverter Fan Assembly- Complete 08/30/ Fan Assembly- Complete A Damper- Backdraft 3 6B Fan Prop, C Fan Shaft D Bearing E Fan Sheave F Bushing- Fan Sheave G Belt H Motor Sheave I Motor Motor Tube- Plastic Coupling- Tube.5 x.5 FPT Fitting- Grease Quantity= when Inverter model 3500 (Code 5= G) is used. Quantity shown are for fans. Quantities for 3 fan units: Ref. 5= 3 ; Ref. 53= 6; Ref. 54= 6. 3 Contact Daikin Applied with model and serial number information so that the correct part can be identified. 4 Quantity is PER fan. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 33

34 Section A- Outdoor/Return Air Section Prop Exhaust Fan Inverters AFD0 Code 0= HE, HY, JE, JY AND Code 4=, 3 Inverter- Fan Units (Code 4= ) 05/3 & Earlier Voltage Code Inverter Model Part 5= Number A ACH ACH G R VTAC VTAC S MD MD Inverter- 3 Fan Units (Code 4= 3) Voltage Code Inverter Model Part 5= Number A ACH ACH G R VTAC VTAC S MD MD The Keypad Display for Model 550 Inverters is p/n For Inverters, contact Daikin Applied with model and serial number information so that the correct Inverter can be identified. Inverter- Fan Units (Code 4= ) Voltage 4 Code Inverter Model Part 5= Number A ACH ACH B MD MD G Q MD MD R VTAC VTAC S, Q MD MD /3 & Later Inverter- 3 Fan Units (Code 4= 3) Voltage 4 Code Inverter Model Part 5= Number A ACH ACH B MD MD G R VTAC VTAC S, Q MD MD The Keypad Display for Model 550 AND MD4 Inverters is p/n For Inverters, contact Daikin Applied with model and serial number information so that the correct Inverter can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 34

35 MMP5 MMP5 Section A- Outdoor/Return Air Section Prop Exhaust Fan Control Box Until 3/ Fan Unit shown Voltage Ref. Sch. Part Part No. Sym. Description Number 0 PB0 Power Block M5, 5 Contactor OL5, 5 Overload 36 Heater- Overload 6 6 Heater- Overload 6 6 NOTE: Quantites for Contactors and Overloads shown are for a Fan unit (Code 4= ). PB0 is used on units where the Inverter is field installed (Code 5= F). Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. 3/05 thru 0/ MMP5 and MMP5 Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 40 MMP5, 5 MMP- Prop Exh. Motors MMP- Prop Exh. Motors MMP- Prop Exh. Motors Line Shield Short Circuit Alarm NOTE: Quantity shown is for a Fan unit (Code 4= ). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 35

36 Section A- Outdoor Air/Return Air/Economizer Section Prop Exhaust Fan Control Box /06 thru 5/3 OL5 M5 OL5 M5 0 Contactors & Overloads Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor Contactor NOTE: Quantity shown is for a Fan unit (Code 4= ). Fan Units 30 06/3 & Later Prop Exhaust Fan Control Box 0 30 OL5 OL5 M5 M5 Fan Unit shown 0 30 Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload Overload Overload Overload M5, 5 Contactor 5A Contactor 6A Contactor 9A Contactor 7A NOTE: Quantity shown is for a Fan unit (Code 4= ). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 36

37 Section A- Outdoor Air/Return Air/Economizer Section Design Flow: Code 0= FE, GE, JE LH Louvered Door Assy 0 Louvered Door Assembly Detail Section Final Assembly RH Louvered Door Assy Vane Panel Detail Adjuster Control Assy. Detail Spring Detail Ref. Part Part Qty. No. Description Number 9 Potentiometer O Ring- Potentiometer Louver Panel Left Hand Door Louver Panel Right Hand Door Grille Panel- Vane Shaft- Upper Bearing- Lower Crank Arm Assy Left Hand Door Crank Arm Assy Right Hand Door Link Arm 0 Bearing Bearing Spring- Main Spring- Secondary N/S Leveling Kit- Design Flow N/S= Not shown on diagram. Quantity is PER door. P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 37

38 Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan: Code = 44B* Ref. Motor Part Part Qty. No. HP Description Number Motor see following page 4 All Mount- Motor All Channel Assembly All Adjustment Bolt Assy., Motor Base All Clamp- Motor Channel All Clamp- Motor Channel All Shaft- Fan.438 dia All Tubing- Plastic All Coupling until / All Coupling /04 & later All Coupling All Fitting- Grease /8 MPS All Bearing- Ball, Flange.437 Opposite Drive End All Bearing- Roller,.437 Drive End All Key- Wheel 5/8 X 6½ All Key- Fan Sheave 5/8 x 5½ All Wheel- SISW All Funnel- Inlet All Lock Collar All Lock Washer All Cap Screw Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification.. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 38

39 Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Fan Mounts: Code = 44B* Until /04 Mounting Layout Diagram 6 OR 6 6 OR 6 63 OR OR Rubber Mounts Rubber Mounts (Code = 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Red , 60 Rubber Mount- Black Rubber Mount- Red , 60 Rubber Mount- Black All Rubber Mount- Red All Rubber Mount- Red All Screw- Cap, 3/8-6 X All Washer- Lock, 3/ All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Spring Mounts (Code = 44B) & Seismic Spring (44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Support Assembly All Screw Adjust Assembly All Channel Assembly All Plate- Gasket Retainer All Support- Spring Locator All Pad- Rubber Vibration Mount- Spring, Red Mount- Spring, Green Mount- Spring, Red Mount- Spring, Green All Mount- Spring, Red All Mount- Spring, Red All Nut- 5/ All Screw- Cap, 3/8-6 X All Washer- Lock, 3/ N/S All Screw- Tapping, / RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 39

40 Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Fan Mounts: Code = 44B* /04 & Later Mounting Layout Diagram 6 OR 6 6 OR 6 63 OR OR Rubber Mounts 6 6 Spring Mounts Seismic strap used only when Code 3= 44B Rubber Mounts (Code = 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Red , 60 Rubber Mount- Black Rubber Mount- Red , 60 Rubber Mount- Black All Rubber Mount- Red All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring (Code = 44B) & Seismic Mounts (Code = 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code = 44B) Seismic (Code = 44B3) Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Brown Spring Mount- Red Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Brown Spring Mount- Red All Nut Spring (Code = 44B) Seismic (Code = 44B3) All Nut All Screw Spring (Code = 44B) 0470 Seismic (Code = 44B3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 40

41 Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Motors Standard Motors: Code = **Y H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C=**Y Voltage C= *EY C= *JY C= *GY C= *KY C09= 3 H*Y 08/60/ J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ R*Y 08/60/ S*Y 08/60/ T*Y 08/60/ N/A C09= 9 3 H*Y 30/60/ J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ R*Y 30/60/ S*Y 30/60/ T*Y 30/60/ N/A C09= 7 3 H*Y 460/60/ J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ T*Y 460/60/ C09= 37 3 H*Y 575/60/ J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ T*Y 575/60/ N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

42 Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code = **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C= **S Voltage C= *JS C= *KS 3 H*S 08/60/ J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ R*S 08/60/ S*S 08/60/ T*S 08/60/ N/A 3 H*S 30/60/ J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ R*S 30/60/ S*S 30/60/ T*S 30/60/ H*S 460/60/ J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ T*S 460/60/ H*S 575/60/ J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ T*S 575/60/ N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

43 Section A- Outdoor Air/Return Air/Economizer Section Section Mounted Controls OAE, OAT, RAE, RAT, SD, LT, S, REC Bottom Return Shown Code 9= BY, BE Bottom Return Shown Code 9= BY, BE OAT Sensor Back Return (Code 9= HY) Economizer Damper Economizer Damper Return Air Opening RAT Sensor Return Air Opening Bottom Return (Code 9= BY, BE) OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n & Mount Minor field modifications are required for proper installation & operation when changing to the newer design. OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE Note that BOTH original controls are obsolete & no longer available. For the OAE Control use & Mount p/n For the RAE Control use & Mount p/n When changing one of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION since the old and new parts are NOT compatible with each other. Also, minor field modifications are required for proper installation & operation when changing to the newer design. RAT/OAT- Return/Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 558 RA/OA Air Temp. Sensor- RAT (MTII) RA/OA Air Temp. Sensor- RAT (MTIII) SD- Return Air Smoke Detector (Code 6=, 3) Ref. Part Part Qty. No. Description Number 30 Smoke Detector (SD) When replacing SD, reuse existing Sampling Tubes or order pc for Standard Discharge OR pc. of for Side or Top Discharge. LT- Return Fan Light/S- Return Fan Light Switch/ REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 43

44 Section B- Draw-Thru Filter Section Notes & Section Mounted Controls Primary Codes that pertain: 5, 33 (Mid 0 & Later) Additional Codes that pertain: 06, 9, 0 Notes Code 5 determines all of the section characteristics. Refer to the Nomenclature, Unit Code Index section for an explanation of Filter codes. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. Code 06 determines the final assembly panel part numbers. For sheet metal components that make up the Draw-Thru Filter Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Codes 9 and 0 determine the Return Air Section which has an effect on the final assembly panels. Section Mounted Controls PC5, LT3, S3, REC3, Magnehelic/Differential Pressure Gauges Controls PC5 Ref. Part Part Qty. No. Description Number 65 PC5 Pressure Ctl LT3- Filter Section Light; S3- Filter Section Light Switch; REC3- Filter Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC Magnehelic/Differential Pressure Gauge Code 33= A****, B****, C**** (Mid 0 & Later) Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 44

45 Section B- Draw-Thru Filter Section Filters Typical Angular Filter Section Shown Code 5= A* Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section (Code 5= A*, D*, E*, G*) N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B % Pleated, 6 x 5 x " w/ Intersept MERV 8 *C % Disposable, 6 x 5 x MERV 3 *H N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B % Disposable, 6 x 0 x " w/ Intersept MERV 8 *C % Disposable, 6 x 0 x MERV 3 *H 9005 N/S Media Filler Piece ALL N/S Angle Assembly ALL Flat Filter Section (Code 5= F*, H*) N/S Filter, Cartridge 65% Cartridge, 4 x 4 x " MERV *D % Cartridge, 4 x 4 x " MERV 4 *E % Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x " MERV *D % Cartridge, x 4 x " MERV 4 *E % Cartridge, x 4 x " w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL 0460 Gasket, Pre Filter ALL N/S Pre Filter, x 4 x ALL Gasket, Pre Filter ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Optional- Angle is mounted on leaving air side. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 45

46 Section B- Draw-Thru Filter Section Filters, Continued Ref. Part Code Part Qty. No. Description 5= Number Staggered Filter Section (Code 5= S*, T*, V*) 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL Gasket, Pre Filter ALL Staggered Filter Section (Code 5= L*) 65% Cartridge, 4 x 4 x MERV *D % Cartridge, 4 x 4 x MERV 4 *E % Cartridge, 4 x 4 x w/ Intersept MERV 4 *G % Disposable, 4 x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x 4 ALL N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D % Cartridge, x 4 x MERV 4 *E % Cartridge, x 4 x w/ Intersept MERV 4 *G % Disposable, x 4 x MERV 3 *H Gasket, Cartridge 5/8 x /6 x ALL N/S Pre Filter, 4 x 4 x ALL Gasket, Pre Filter ALL N/S Pre Filter, x 4 x ALL Gasket, Pre Filter ALL Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 46

47 Section C- Blank/Inverter (AFD/VFD) Section Notes & Section Mounted Controls Primary Codes that pertain: 6, 4, 5 Additional Codes that pertain: 06 Notes Code 6 determines if a Blank/Inverter Section is installed. If Code 6= F, S there is a 48 section. If Code 6= E there is a 4 section installed. If Code 6= Y, there is no Blank/Inverter Section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=,, 4 AND Code 6= E, F there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. Code 5 identifies the inverter brand supplied. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Inverter Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section Mounted Controls LT9- Blank/Inverter Section Light; S9- Blank/ Inverter Section Light Switch; REC9- Blank/ Inverter Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 47

48 Section D- Draw-Thru Cooling Section Notes Primary Codes that pertain: 03, 7, 8, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil (4 section for unit sizes 076 thru 00C, or normally a 48 section for unit size 0C although a few units have a 4 section installed). If Code 03= L it is a large face area Coil (48 section for unit sizes 076 thru 00C, or 4/48 for unit sizes 0C thru 50C). Small face area Coils are not available on 30 thru 50C unit sizes. Code 7 determines the characteristics of the Draw-Thru Cooling Section. If Code 7= YYYY, there is no Section. For RPE units this indicates that the Cooling Coil is in the Blow-Thru position (see Section I); RDE units (typical RDE unit shown in the above diagram) always have a Draw-Thru Cooling Section. If the code is CYYY, CYYS then there is a unit Cooling Coil and Drain Pan. An S in the fourth position of Code 7 means the Drain Pan is stainless steel. A Y in the fourth position indicates that the Drain Pan is made of painted galvanized steel. Code 8 determines the Cooling Coil characteristics. Code 8 will apply only if Code 7= CYYY, CYYS AND Code 36= YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Draw-Thru Cooling Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. NOTE: The drawings and components listed in this section also apply to Section I Blow-Thru Cooling Section (RPE only). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 48

49 Section D- Draw-Thru Cooling Section Evaporator Coils & Drain Pans, Small Face DX Evaporator Coils: Code 03= S Small Face Area Coil 4 Section Unit Sizes 076 thru 0C 400 Ref. Part Part Qty. No. Description Number Coil 300 Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Pan- Auxilliary Before /06 Stainless (C7= CYYS) After /06 Stainless (C7= CYYS) Small Face Area Coil 48 Section Unit Size 0C Ref. Part Part Qty. No. Description Number Coil- Upper Coil- Lower 400 Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Pan- Auxilliary Pan- Liner Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Evaporator coils are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. 0C units may have either a 4 OR a 48 Section installed. Confirm section size before ordering or contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 49

50 Section D- Draw-Thru Cooling Section Evaporator Coils & Drain Pans, Large Face DX Evaporator Coils: Code 03= L Large Face Area Coil 48 Section Ref. Part Part Qty. No. Description Number Coil- Lower Coil- Upper 400 Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Pan- Auxilliary Pan- Liner Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Large Face Area Coil 4/48 Section Ref. Part Part Qty. No. Description Number Coil- Lower Coil- Upper 400 Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Pan- Auxilliary Pan- Liner Drain Pan Galvanized (C7= CYYY) Stainless (C7= CYYS) Evaporator coils are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. 089 thru 50C units may have either a 48 OR a 4/48 (7 OAL) section installed. Confirm section size before ordering or contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 50

51 Section E- 48 Draw-Thru Spacer/Blank Section Notes Primary Codes that pertain: 6, 30 Additional Codes that pertain: 06 Code 6 & 30 determine all of the section characteristics. If Code 6= F, S AND/OR Code 30= BBBBBB there is a 48 Blank/Spacer Section. If Code 6= E AND/OR Code 30= EEEEEE there is a 4 Blank/Spacer Section. If Code 6= Y AND/OR Code 30= YYYYYY, there is no section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 Draw-Thru Spacer/Blank Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section E- Draw-Thru Heat Section for RDE Units Notes Primary Codes that pertain: 04, 30 Additional Codes that pertain: 06 Code 04 determines what type of heat was specified. Draw-Thru Heat units typically are hydronic with Hot Water (Code 04= H) OR Steam (Code 04= S) heat. If Code 04= E (Electric Heat), contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 30 determines the Hydronic Heating Coil and associated Valve characteristics OR Electric Heat specifications. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 RDE Draw-Thru Heat Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section Mounted Controls LT8- Draw-Thru Heat Light; S8- Draw-Thru Heat Light Switch; REC8- Draw-Thru Heat Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

52 Section E- Draw-Thru Heat Section for RDE Units Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM Code 30= W***, W***, OR S***, S***, S3***, S4*** Coil Location Mixing Valve Detail Air Flow Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C Valve, 3 Way- Hot Water Heat.5 W**E3* ALL ALL W**F3* ALL ALL W**G3* ALL ALL W**H3* ALL ALL W**J3* ALL ALL Linkage-.5 thru.00 Valve *****E ALL ALL Linkage-.50, 3.00 Valve *****E ALL ALL VM Actuator 0V *****E ALL ALL For Steam Heat Coils and Components (Code 30= S*****) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Hot Water Heat 3.00 Valve uses Flange Gasket p/n: RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

53 Section F- Supply Air Section Notes Primary Codes that pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later) Additional Codes that pertain: 04, 06, 08, 4, 5, 34, 40, 49 Code 3 determines the Supply Fan size, type, and mounting method. RPE units can have a 33, 36, 40 Airfoil OR Forward Curved Wheel. If the unit is equipped with a Forward Curved Wheel (Code 3= **F*, **M*) contact Daikin Applied so that the required part(s) can be identified. RDE units can have either a 44 OR a 49 Airfoil Wheel. Digit four of Code 3 indicates the Fan Mounting type. If digit four is a the unit has Rubber-In-Shear (RIS) isolators. If digit four is a the unit has Spring Isolators. If digit four is 3 the unit has Spring Isolators with Seismic Snubbers. Code 3 determines the Supply Fan Motor horsepower and type. Fan Motors range from horsepower. Note that 75 horsepower Motors are NOT available in (Code 09= ) OR (Code 09= 9). Code 33 (Mid 0 & Earlier) OR Code 59 (Mid 0 & Later) determine the Drive Components selected. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification. Code 04 AND Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the discharge plenum, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 08 determines the location of the unit s Main Control Box. RDE units with no Blow-Thru Section have their Main Control Boxes in the Supply Air Section. Codes 4 & 5 determine if the unit has Inverter(s) and if so where they are installed. If Code 4= 3, 5, 6, 7, 8, 9 the Inverter(s) are installed in the Supply Air Section. If Code 4=,, 4 AND Code 6= E, F, S, there is a separate Inverter Section. If Code 4= Y, there are no factory supplied Inverters. Code 5 references which Inverter vendor was selected. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the Supply and Return Air Inverters are listed in this section. Code 40 determines the Discharge Plenum configuration. RDE units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with Actuator ACT5. The Isolation Damper and related components are detailed in the Discharge Plenum Section (Section K). Code 49 determines if the Supply Air section is supplied with a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 53

54 Motor (See Motor list after Fan Mount section.) Section F- Supply Air Section Air Foil Fan, Double Width Code 3= 33A*, 36A*, 40A* Inlet Funnel Cut Off Plates Ref. Part Part Fan Size No Description Number Housing Assy- Blower (Code 3= 33A*) Inlet Funnel only Cut Off Plate only Housing Assy- Blower (Code 3= 36A*) Inlet Funnel only Cut Off Plate only Housing Assy- Blower (Code 3= 40A*) Inlet Funnel only Cut Off Plate only Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Wheel, Fan- Single Inlet Single Width CCW Screw Adjust Assembly Shaft-.438 Diameter Shaft-.688 Diameter Shaft-.938 Diameter Motor Mount Assembly Angle- Motor Mount Holddown Angle, Clamping Key- Fan 4.75 Long X 5/8 Diameter 0367 Key- Fan 0.00 Long X 5/8 Diameter 0363 Key- Fan 5.50 Long X 3/4 Diameter 0370 Key- Sheave 6.50 Long X / Diameter 0360 Key- Sheave 5.50 Long X 3/4 Diameter Bearing- Ball.437 Bore Bearing- Ball.688 Bore Bearing- Ball.938 Bore Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is needed use the number from the part and cross reference it with the Cross Reference: Drive Components Form number: 57006, or contact Daikin Applied to ensure that the required part(s) are correctly identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 54

55 Section F- Supply Air Section Air Foil Fan, Single Width Code 3= 44B*, 49B* Motor (See Motor list after Fan Mount section.) 6 5 Ref. Part Part Fan Size No. Description Number Wheel, Fan- Single Inlet/Single Width Wheel, Fan- Single Inlet/Single Width Inlet Funnel Assembly Inlet Funnel Assembly Screw Adjust Assembly Shaft-.438 Diameter Shaft-.88 Diameter Mount Assembly-Motor Angle- Motor Mount Angle, Clamping Key- Fan, 6.50 Long X 5/8 Diameter 0360 Key- Fan, 6.00 Long X / Diameter 0350 Key- Fan, 5.50 Long X 5/8 Diameter Key- Fan, 6.00 Long X / Diameter Tubing- Plastic Tubing- Plastic Bearing- Ball,.437 Bore Bearing- Ball,.88 Bore Fitting- /4 OD X /8 MPT Fitting- /4 OD X /8 FPT Bearing- Ball,.437 Bore Bearing- Roller,.88 Bore Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is needed use the number from the part and cross reference it with the Cross Reference: Drive Components Form number: 57006, or contact Daikin Applied to ensure that the required part(s) are correctly identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 55

56 Section F- Supply Air Section Fan Mounts- 33 Airfoil Double Width Fan Code 3= 33A, 33A, 33A3 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR Rubber Mounts Rubber Mounts (Code 3= 33A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support , 7.5 Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green Rubber Mount- Black Rubber Mount- Red All Nut All Screw All Nut, / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Seismic strap used only when Code 3= 33A Spring (Code 3= 33A) & Seismic Mounts (Code 3= 33A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 33A) Seismic (Code 3= 33A3) , 7.5 Spring Mount- Green Spring Mount- Brown , 50 Spring Mount- Red All Spring Mount- Brown , 7.5 Spring Mount- Brown Spring Mount- Red , 50 Spring Mount- Red/Black All Spring Mount- Red All Nut Spring (Code 3= 33A) Seismic (Code 3= 33A3) All Nut All Screw Spring (Code 3= 33A) 0470 Seismic (Code 3= 33A3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 56

57 Section F- Supply Air Section Fan Mounts- 36 Airfoil Double Width Fan Code 3= 36A, 36A, 36A3 Until /04 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR Rubber Mounts (Code 3= 36A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support All Rubber Mount- Red , Rubber Mount- Red , 60, 75 Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green , 75 Rubber Mount- Gray All Rubber Mount- Red All Screw- Cap, 3/8-6 X All Washer- Lock, 3/ All Nut, / All Screw- Cap, /-3 X Spring Mounts (Code 3= 36A, 36A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Support Assembly All Screw Adjust Assembly All Channel Assembly Mount- Spring, Red Mount- Spring, Green Mount- Spring, Red Mount- Spring, Dk. Yellow Mount- Spring, Blue Mount- Spring, Red Mount- Spring, Green All Mount- Spring, Red All Plate- Gasket Retainer All Support- Spring Locator All Pad- Rubber Vibration All Nut, 5/ All Screw- Cap, 3/8-6 X All Washer- Lock, 3/ N/S All Screw- Tapping, / RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 57

58 Section F- Supply Air Section Fan Mounts- 36 Airfoil Double Width Fan Code 3= 36A, 36A, 36A3 /04 & Later Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR Rubber Mounts Spring Mounts Seismic strap used only when Code 3= 36A Rubber Mounts (Code 3= 36A, 36V) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support All Rubber Mount- Red , Rubber Mount- Red , 60, 75 Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green , 75 Rubber Mount- Gray All Rubber Mount- Red All Nut All Screw All Nut, / All Screw- Cap, /-3 X All Washer- Plain, / Spring (Code 3= 36A) & Seismic Mounts (Code 3= 36A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 36A) Seismic (Code 3= 36A3) , 5 Spring Mount- Brown Spring Mount- Red , 75 Spring Mount- Red/Black All Spring Mount- Brown , 5 Spring Mount- Red Spring Mount- Red/Black , 75 Spring Mount- Red/Green Spring Mount- Red Spring Mount- Red/Black All Nut Spring (Code 3= 36A) Seismic (Code 3= 36A3) All Nut All Screw Spring (Code 3= 36A) 0470 Seismic (Code 3= 36A3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 58

59 Section F- Supply Air Section Fan Mounts- 40 Airfoil Double Width Fan Code 3= 40A, 40A, 40A3 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR Rubber Mounts Spring Mounts Seismic strap used only when Code 3= 40A Rubber Mounts (Code 3= 40A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Red , 75 Rubber Mount- Green Rubber Mount- Red Rubber Mount- Black , 5 Rubber Mount- Red Rubber Mount- Green , 75 Rubber Mount- Gray All Rubber Mount- Red All Nut All Screw All Nut, / All Screw- Cap, /-3 X All Washer- Plain, / Spring (Code 3= 40A) & Seismic Mounts (Code 3= 40A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 40A) Seismic (Code 3= 40A3) Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black Spring Mount- Red/Green Spring Mount- Red Spring Mount- Red/Black All Nut Spring (Code 3= 40A) Seismic (Code 3= 40A3) All Nut All Screw Spring (Code 3= 40A) 0470 Seismic (Code 3= 40A3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 59

60 Section F- Supply Air Section Fan Mounts- 44 Airfoil Single Width Fan Code 3= 44B, 44B, 44B3 Mounting Layout Diagram 3 OR 33 OR OR 3 34 OR Rubber Mounts Rubber Mounts (Code 3= 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support Rubber Mount- Black Rubber Mount- Red All Rubber Mount- Red , 0 Rubber Mount- Black Rubber Mount- Red Rubber Mount- Green All Rubber Mount- Red All Nut All Screw All Nut- / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Seismic strap used only when Code 3= 44B Spring (Code 3= 44B) & Seismic Mounts (Code 3= 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 44B) Seismic (Code 3= 44B3) Spring Mount- Green Spring Mount- Brown Spring Mount- Red All Spring Mount- Brown Spring Mount- Brown Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Red All Nut Spring (Code 3= 44B) Seismic (Code 3= 44B3) All Nut All Screw Spring (Code 3= 44B) 0470 Seismic (Code 3= 44B3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 60

61 Section F- Supply Air Section Fan Mounts- 49 Airfoil Single Width Fan Code 3= 49B, 49B, 49B3 Mounting Layout Diagram 3 OR 33 OR OR 3 34 OR Rubber Mounts Rubber Mounts (Code 3= 49B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support All Rubber Mount- Red All Rubber Mount- Red Rubber Mount- Red Rubber Mount- Green Rubber Mount- Red Rubber Mount- Green All Nut All Screw All Nut, / All Screw- Cap, /-3 X All Washer- Plain, / Spring Mounts Seismic strap used only when Code 3= 49B Spring (Code 3= 49B) & Seismic Mounts (Code 3= 49B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 49B) Seismic (Code 3= 49B3) Spring Mount- Red , 50 Spring Mount- Red/Black , 75 Spring Mount- Red/Green All Spring Mount- Red/Black Spring Mount- Red Spring Mount- Red/Black All Spring Mount- Red/Black All Nut Spring (Code 3= 49B) Seismic (Code 3= 49B3) All Nut All Screw Spring (Code 3= 49B) 0470 Seismic (Code 3= 49B3) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

62 H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C3=**Y Voltage C3= *EY C3= *JY C3= *HY C3= *KY C09= 5 J*Y 08/60/ K*Y 08/60/ L*Y 08/60/ M*Y 08/60/ N*Y 08/60/ P*Y 08/60/ Q*Y 08/60/ R*Y 08/60/ S*Y 08/60/ T*Y 08/60/ N/A 75 U*Y 08/60/ N/A C09= 9 5 J*Y 30/60/ K*Y 30/60/ L*Y 30/60/ M*Y 30/60/ N*Y 30/60/ P*Y 30/60/ Q*Y 30/60/ R*Y 30/60/ S*Y 30/60/ T*Y 30/60/ U*Y 30/60/ C09= 7 5 J*Y 460/60/ K*Y 460/60/ L*Y 460/60/ M*Y 460/60/ N*Y 460/60/ P*Y 460/60/ Q*Y 460/60/ R*Y 460/60/ S*Y 460/60/ T*Y 460/60/ U*Y 460/60/ C09= 37 5 J*Y 575/60/ K*Y 575/60/ L*Y 575/60/ M*Y 575/60/ N*Y 575/60/ P*Y 575/60/ Q*Y 575/60/ R*Y 575/60/ S*Y 575/60/ T*Y 575/60/ U*Y 575/60/ N/A= Not Available. Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 3= **Y RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

63 Section A- Outdoor/Return Air Section Supply Air Fan Motors Shaft Grounded Motors: Code 3= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C3= **S Voltage C3= *JS C3= *KS C09= 5 J*S 08/60/ K*S 08/60/ L*S 08/60/ M*S 08/60/ N*S 08/60/ P*S 08/60/ Q*S 08/60/ R*S 08/60/ S*S 08/60/ T*S 08/60/ N/A 75 U*S 08/60/ N/A C09= 9 5 J*S 30/60/ K*S 30/60/ L*S 30/60/ M*S 30/60/ N*S 30/60/ P*S 30/60/ Q*S 30/60/ R*S 30/60/ S*S 30/60/ T*S 30/60/ U*S 30/60/ C09= 7 5 J*S 460/60/ K*S 460/60/ L*S 460/60/ M*S 460/60/ N*S 460/60/ P*S 460/60/ Q*S 460/60/ R*S 460/60/ S*S 460/60/ T*S 460/60/ U*S 460/60/ C09= 37 5 J*S 575/60/ K*S 575/60/ L*S 575/60/ M*S 575/60/ N*S 575/60/ P*S 575/60/ Q*S 575/60/ R*S 575/60/ S*S 575/60/ T*S 575/60/ U*S 575/60/ N/A N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 63

64 Section F- Supply Air Section Belt Guards: Code 49= A, C, D, F 4 40 Air Foil Double Width (AFDW) OR Forward Curved Fans (FCLP, FCMP) Ref. Part Part Fan Size No. Description Number Grille Assembly Grille Assembly Grille Assembly Belt Guard Assembly Belt Guard Assembly Belt Guard Assembly Air Foil Single Width (AFSW) with Side Discharge (Code 40= H*), Main Control Box (Code 08= S, F) The main control box is mounted in this section on RDE units (the Supply Air Section is mounted directly to the condenser section). Air Foil Single Width (AFSW) with Side Discharge (Code 40= S*), No Control Box (Code 08= P, D, Y) RPE units (Main Control Box is mounted in the Discharge Plenum Section K) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G*), Main Control Box (Code 08= S, F) The main control box is mounted in this section on RDE units (the Supply Air Section is mounted directly to the Condenser section) Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B*), No Control Box (Code 08= P, D, Y) RPE units (Main Control Box is mounted in the Discharge Plenum Section K) Ref. Part Part Fan Size No. Description Number Grille Assy Grille Assy Grille Assy Grille Assy Grille Assy Grille Assy RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 64

65 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 5 (Code OR Code 3= J**) Diagrams Inverters may be located in a separate section (Code 4=,, 4), OR the Supply Air Section (Code 4= 3, 5, 6, 7, 8, 9). The Inverter and Bypass components are the same regardless of the installation location, although the sheet metal components differ. The diagrams shown below apply to either a Return Air OR Supply Air Inverter (both may be installed if Code 4= 5, 7). Even if Code 4= 8, 9 where only a Return Air Fan Inverter is called for the Inverter and Bypass controls are still normally installed in the Supply Air Section. MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air OR Return Air Fan Inverter with Bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) MMP & Contactor Link Detail 76 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 65

66 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 5 (Code OR Code 3= J**) Components Motor HP 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Alarm- Short Circuit Alarm/Aux. Contact Line Shield Cover- Contactor Link Module RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 66

67 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n ** MMP & Contactor Link Detail MMP p/n ,06,07, MMP & Contactor Link Detail MMP p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 67

68 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section 50 Gasket MMP30,40 Motor Control LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Alarm- Short Circuit Alarm/Aux. Contact Line Shield Cover- Contactor Aux. Contact Block Link Module Aux. Contact Lug RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 68

69 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) MMP & Contactor Link Detail MMP p/n , MMP & Contactor Link Detail MMP p/n ** MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n , 07 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 69

70 Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section Also requires 3 field supplied ring terminals. 50 Gasket MMP30 Motor Control MMP LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Alarm- Short Circuit Cover- Contactor Aux. Contact Block Link Module Aux. Contact Lug RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 70

71 Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 5 (Code OR Code 3= J**) MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 Motor HP MMP & Contactor Link Detail 75 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Contact- Auxiliary Contact- Auxiliary Link Spacer Side Mounted, NO/ NC. Until 0/07. Front Mounted, NO OR NC. 0/07 & Later. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

72 Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) MMP & Contactor Link Detail MMP p/n ** 7 MMP & Contactor Link Detail MMP p/n , MMP & Contactor Link Detail MMP p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

73 Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Control LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Contact- Auxiliary Link Spacer Interlock- Trip Lug Kit (3 per kit) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 73

74 Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n , 48, MMP & Contactor Link Detail MMP p/n MMP & Contactor Link Detail MMP p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 74

75 Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see page after Inverters Also requires 3 field supplied ring terminals. 50 Gasket MMP30 Motor Control MMP LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I Contact- Auxiliary Contact- Auxiliary Link Spacer Interlock- Trip Lug Kit (3 per kit) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 75

76 Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 5 (Code = J** OR Code 3= J**) MMP30 (Supply) MMP40 (Return) 7 7 LR0 (Supply) LR0 (Return) Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) Supply Air or Return Air Fan Inverter w/ Bypass Control Box shown. (Code 4= 3, 5, 8) Two boxes installed if Code 4= 5 Phase Barrier 70A Front Mtd. Aux. Contact MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) Link 70C 7 7A Spacer Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 08/ Link 70C 7 Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 460/ Motor HP 5 Ref Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 50 Gasket MMP30, 40 Motor Protector A Phase Barrier B Aux. Contact C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor M40B, I A Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 76

77 Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams 40 Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 7, 9) MMP30 (Supply) 70 LR0 (Supply) 7 MMP40 (Return) 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/ 5, 0 HP Motors- 0 HP Motors- 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 08/30/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 77

78 Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower Ref Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket MMP30,40 Motor Protector A Phase Barrier B Contact- Auxiliary C Link LR0, 0 Line Reactor- see page after Inverters 7 M30B, I M40B, I Contactor 9A A A A A A A A A Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 78

79 Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 7, 9) LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code4= M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Front Mtd. Aux. Contact 70B MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C Link 70C 7 7 Contactor Contactor MMP30/40 & M30/40 Link Detail 30 HP Motors- 460/ 40 HP Motors- Contactors 7 MMP30/40 & M30/40 Link Detail 30 HP Motors- 08/ 40 HP Motors- 50, 60 HP Motors- 460/ 75 HP Motors- Overload 78 Interlock 79 MMP30/40 & M30/40 Link Detail 40, 50, 60 HP Motors- 08/ 75 HP Motors- 08/30/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 79

80 Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower Ref Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see next page 50 Gasket MMP30 Motor Protector MMP A A A A A A A Phase Barrier B Contact- Auxiliary C Link LR0,0 Line Reactor- see page after Inverters 7 M30B, I Contactor 5A M40B, I Contactor 85A A A A A A A A OL30 Overload 50-50A OL40 Overload 50-00A A Mechanical Interlink Mechanical Interlink N/S CB30,40 Circuit Breaker 5A Circuit Breaker 50A N/S= Not Shown on Diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 80

81 Section F- Supply Air Section Inverters AFD0 (Return) AFD0 (Supply) Supply Air and Return Air Fan Inverter without Bypass (Code 4= 7) Supply Air or Return Air Fan Inverter without Bypass (Code 4= 6, 7, 9) AFD0/AFD0 Ref. No. 40 Code 5= R: Model VTAC9 08/ Motor Horsepower Part Number Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

82 Section F- Supply Air Section Inverters, Continued AFD0/AFD0 Ref. No. 40 Code 5= A: Model ACH550 08/ Motor Horsepower / 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ Part Number The replacement Keypad Display is p/n Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

83 Section F- Supply Air Section Inverters, Continued AFD0/AFD0 Ref. No. 40 Code 5= G: Model 3500 Motor Horsepower Part Number Motor Horsepower Part Number Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 83

84 AFD0/AFD0 Ref. No. 40 Code 5= S, Q: MD, MD3, MD6 Section F- Supply Air Section Inverters, Continued Motor Horsepower / 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ Part Number , , , , , Units built late 00 & Earlier shipped with ATV VFDs. All ATV drives have been replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n The ATV Lonworks communication card is p/n The ATV Remote Keypad is p/n and the Remote Keypad Mounting kit is p/n The ATV Lonworks communication card is p/n All other ATV communication cards are integral to the VFD and are not available separately. Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). MD3 Remote Keypad p/n is MD6 Remote Keypad p/n is plus Mount p/n For units with an MD3 Inverter and Motor under 5 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). See one page after next for Line Reactor part numbers. 5 Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 84

85 AFD0/AFD0 Ref. No. 40 Code 5= B: MD4, MD5 08/ Section F- Supply Air Section Inverters, Continued Motor Horsepower / 08/ 08/ 08/ 08/ 08/ 08/ Part Number The replacement VFD Keypad Display is p/n Note that 60 & 75 HP motors are not available in 08/ (Code =, 9). 08/ 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 85

86 Section F- Supply Air Section Line Reactors / Motor Horsepower / / / / / / / / / / Part Number Line Reactors are optional for all voltages and motor sizes except for MD3 Inverters (Code 5= S, Q ) - 0 HP. These will always have a Line Reactor installed regardless of Code 7. These are 5% impedance Line Reactors. Some units may have had 3% impedance Line Reactors installed. The 5% is to be used in place of the 3% Reactors. If replacing a 3% impedance Line Reactor, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 86

87 Section F- Supply Air Section Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket, 9 PC7 Pressure Control 0 Pneumatic Fitting In 6/ the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n , the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 66 Support T-stat- HL Hi Limit LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Receptacle Code 49= B, E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC UV Lights Code 7= C thru C8 AND Y thru Y8 99 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8 Bulb Light Fixture- 4 Bulb Light Fixture- 36 Bulb Bulb/Lamp, UV Bulb/Lamp, UV Bulb/Lamp, UV RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 87

88 Section F- Supply Air Section Section Mounted Controls MAT, EFT, SAT, DAT, OAT, SD 5 66 Entering Fan Temperature Sensor- EFT Ref. Part Part Qty. No. Description Number 5 EF Temp. Sensor MicroTech II MicroTech III Support Bracket Discharge Air Temperature Sensor- DAT Ref. Part Part Qty. No. Description Number 8 DA Temp. Sensor MicroTech II MicroTech III Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor MicroTech II MicroTech III Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD Sensing Tube For Standard Discharge applications. For other options, contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 88

89 Section F- Supply Air Section Section Mounted Controls SCB- Split Junction Box, TB5, TB7, TB8, PB0, PB9, PB0, PB9 Code 05= F TB8 TB7 TB5 PB 9 PB 0 PB 9 PB 0 Typical Split Junction Box Location Across- The- Line Start (Code 0= AL) Motor HP , Sch. Part Part Sym. Description Number Terminal Blocks TB5 Terminal Block- SCB TB7 Terminal Block- SCB TB8 Terminal Block- SCB PB0 Power Block- Supply Fan 95A, 600V, 3P A, 600V, 3P PB9 Power Block- Supply Fan 95A, 600V, 3P PB0 Power Block- Return Fan 95A, 600V, 3P PB9 Power Block- Return Fan 95A, 600V, 3P If Code 0= PW AND Code 05= F, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 89

90 Section G- Blow-Thru Heat Section for RPE Units Notes & Section Mounted Controls Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 08, 09,, 3 This section is divided into four subsections:. Blank Compartment;. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the Heat Section s characteristics. If Code 04= Y, AND Code 34= YYYYYY there is no section. See the Unit Model Number- Complete section at the beginning of this form for specific Heat Section coding. If Code 04= Y AND Code 34= BBBBBB, then there is a 48 Blank Spacer Section installed. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the RPE Blow-Thru Heat Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the Gas Heat Section depending on whether the unit is UL approved (USA) or ETL approved (Canada). Code 08 determines which generation of controls are installed which determines which Electric Heat Controls are used. Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their Controls. Code determines the Control type and will affect the Gas Heat Actuator Motor. Code 3 is the Supply Fan size which affects the Heat Section s Diffusers. Section G pertains to the RPE, but not the RDE. Notes Section Mounted Controls LT- BT Heat Section Light/S- BT Heat Section Light Switch/REC- BT Heat Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 90

91 Section G- Blow-Thru Heat Section for RPE Units Option : Blank Compartment Code 34= BBBBBB AND Code 04= Y Diffuser Factory Mounted Diffuser Field Mounted Diffuser (Split Unit) Ref. Part Part Qty. No. Description Number Diffuser Code 3= 33** Code 3= 36** Code 3= 40** The drawing above left shows a Diffuser factory mounted on a unit split at the condenser (Code 05= C), or not split (Code 05=Y). When a unit is split at the Supply Fan (Section F) and Heat Section (Section G) the Diffuser is packaged for field mounting as shown on the drawing on the right. The part numbers are the same in either case. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

92 Section G- Blow-Thru Heat Section for RPE Units Option : Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM Code 34= W***, W***, OR S***, S***, S3***, S4*** Coil Location Mixing Valve Detail Air Flow Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number Hot Water Heat Coil- Bottom W*** 5WH090H Hot Water Heat Coil- Bottom W*** 5WS090C Hot Water Heat Coil- Top W*** 5WH090H Hot Water Heat Coil- Top W*** 5WS090C Valve/Actuator /0 & Earlier 63 Valve, 3 Way- Hot Water Heat.5 W**E3* ALL ALL W**F3* ALL ALL W**G3* ALL ALL W**H3* ALL ALL W**J3* ALL ALL Linkage-.5 thru.00 Valve *****E ALL ALL Linkage-.50, 3.00 Valve *****E ALL ALL VM Actuator, 0V *****E ALL ALL Valve/Actuator / & Later 63 Valve, 3 Way w/ Actuator- HW.5 W**E3* ALL ALL W**F3* ALL ALL W**G3* ALL ALL W**H3* ALL ALL W**J3* ALL ALL VM Actuator only, 4V *****E ALL ALL For Steam Heat Coils and Components (Code 30= S*****) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Hot Water Heat 3.00 valve has a flange gasket p/n: RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

93 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Heaters, Hi Limit Cutouts, Diffusers 300 Air Flow 7 7A 400 Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 300 Heater Assy- Top 80 E Heater Assy- Top 80 E Heater Assy- Top 80 E N/A Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 00 E00 00 N/A Heater Assy- Top 0 E Heater Assy- Top 0 E Heater Assy- Top 0 E0 0 N/A Heater Assy- Top 60 E Heater Assy- Top 60 E Heater Assy- Top 60 E60 60 N/A Heater Assy- Top 00 E Heater Assy- Top 00 E Heater Assy- Top 00 E00 0 N/A Heater Assy- Top 40 E Heater Assy- Top 40 E Heater Assy- Top 40 E40 0 N/A Heater Assy- Top 80 E Heater Assy- Top 80 E Heater Assy- Top 80 E80 60 N/A Heater Assy- Top 30 E Heater Assy- Top 30 E Heater Assy- Top 30 E30 60 N/A N/A= Not Applicable. Units ETL/MEA USA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual Reset Switches. Units ETL Canada approval (Code 07= CY). Heater Assy. includes Hi Limit auto Reset Switches. 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 93

94 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Heaters, Hi Limit Cutouts, Diffusers, Continued Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 400 Blank Assy- Bottom E/ Heater Assy- Bottom 00 E Heater Assy- Bottom 00 E Heater Assy- Bottom 00 E00 80 N/A Heater Assy- Bottom 40 E Heater Assy- Bottom 40 E Heater Assy- Bottom 40 E40 0 N/A Heater Assy- Bottom 80 E Heater Assy- Bottom 80 E Heater Assy- Bottom 80 E80 0 N/A Heater Assy- Bottom 30 E Heater Assy- Bottom 30 E Heater Assy- Bottom 30 E30 60 N/A HL- 0 Hi Limit- Manual Cutout All All All N/A 7A HL3-50 Hi Limit- Auto Cutout All All All Diffuser All All All N/A= Not Applicable. Units ETL/MEA USA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual Reset Switches. Units ETL Canada approval (Code 07= CY). Heater Assy. includes Hi Limit auto Reset Switches. 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 94

95 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier Disconnect Switch DS3 FB33 FB3 FB3 M33 M3 M3 FB33 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB44 FB34 M33 M3 M36 M3 M35 M33 M3 M3 M44 M34 FB34 H S 3 FB34 H S 3 FB43 FB4 FB4 H S 3 M34 08/ 0KW- 0KW T B M34 460/ 0KW- 60KW T B M43 M4 M4 460/ 00KW- 30KW T B PB3 PB3 PB3 DS3 or PB3 DS3 or PB3 DS3 or PB3 Sch. Part Disconnect Switch Components Sym. Description Amps Switch Handle Shaft Ground Lug DS3 Disconnect Switch 00 Amp Disconnect Switch 50 Amp Disconnect Switch 50 Amp Disconnect Switch 400 Amp Disconnect Switch 600 Amp , Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size. Includes mechanism (except 600A switch, see footnote #3). 3 Handle only p/n ; Mechanism only p/n ; Shaft only p/n Note that the original Disconnect Switch is obsolete. If replacing an original Disconnect Switch, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 95

96 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 0-0KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block Power Block PB3 Power Block- DS3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS Cover- PB3 Power Block HS3 Switch TB Terminal Block M3 Contactor Contactor M3 Contactor Contactor M33 Contactor Contactor M34 Contactor Contactor M35 Contactor M36 Contactor Part number is for one section. The number of sections used is determined by the options installed. Not used when PB3 power block connection is present. 3 Cover- PB3 Power Block is used ONLY when 600A DS3 p/n is supplied. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 96

97 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 0-0KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 97

98 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 60-30KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block PB3 Power Block used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS Cover- PB3 Power Block HS3 Switch TB Terminal Block M3 Contactor M3 Contactor M33 Contactor Contactor M34 Contactor Contactor M4 Contactor Contactor M4 Contactor Contactor M43 Contactor Contactor M44 Contactor Contactor Part number is for one section. The number of sections used is determined by the options installed. Not used when PB3 power block connection is present. 3 Cover- PB3 Power Block is used ONLY when 600A DS3 p/n is supplied. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 98

99 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 60-30KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block FB3 Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB43 Fuse Block Fuse Block FB44 Fuse Block Fuse Block F3 Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB Fuse- FB Fuse- FB F4 Fuse- FB Fuse- FB Fuse- FB Fuse- FB F43 Fuse- FB Fuse- FB Fuse- FB Fuse- FB F44 Fuse- FB Fuse- FB Fuse- FB Fuse- FB RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 99

100 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later Disconnect Switch DS3 FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 FB43 M3 FB4 M3 FB4 H S 3 T B M34 T B M43 M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 08/ 0KW- 60KW DS3 or PB3 460/ 0KW- 60KW DS3 or PB3 460/ 00KW- 40KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A N/A N/A Disconnect Switch- 50A Disconnect Switch- 50A Disconnect Switch- 400A Disconnect Switch- 600A Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. This shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n Three Lugs are included with each p/n. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 00

101 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 0-0KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block 75A Power Block 40A PB3 Power Block 3 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block M3 Contactor 40A Contactor A M3 Contactor 40A Contactor A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M35 Contactor 40A M36 Contactor 40A Part number is for one section. The number of sections used is determined by the options installed. See the chart on the previous page. 3 Not used when PB3 power block connection is present. 4 Cover- PB3 used with 600A DS3 is p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

102 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 0-0KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number FB3 Fuse Block Fuse Block Fuse Block FB3 Fuse Block Fuse Block Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB35 Fuse Block FB36 Fuse Block F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F3 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F33 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F34 Fuse- FB Fuse- FB Fuse- FB Fuse- FB Fuse- FB F35 Fuse- FB F36 Fuse- FB RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

103 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 60-30KW Components Heater KW= Sch. Part Part Sym. Description Number PB3 Power Block PB3 Power Block 4 used w/00a, 50A DS used w/50a DS used w/400a DS used w/600a DS DS3 Disconnect Switch HS3 Switch TB Terminal Block M3 Contactor 40A M3 Contactor 40A M33 Contactor 40A Contactor A M34 Contactor 40A Contactor A M4 Contactor 40A Contactor A M4 Contactor 40A Contactor A M43 Contactor 40A Contactor A M44 Contactor 40A Contactor A FB3 Fuse Block FB3 Fuse Block FB33 Fuse Block Fuse Block FB34 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB4 Fuse Block Fuse Block FB43 Fuse Block Fuse Block FB44 Fuse Block Fuse Block Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Cover- PB3 used with 600A DS3 is p/n Not used when PB3 power block connection is present. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 03

104 Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 60-30KW Components, Continued Heater KW= Sch. Part Part Sym. Description Number F3 Fuse Fuse F3 Fuse Fuse F33 Fuse Fuse Fuse Fuse F34 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F4 Fuse Fuse Fuse Fuse F43 Fuse Fuse Fuse Fuse F44 Fuse Fuse Fuse Fuse RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 04

105 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules 500, 640, 650, 790, 800, 000, 00, 400MBH Code 34= 050***, 064***, 065***, 079***, 080***, 00***, 0**, 40*** 3 Burner 4 Burner Control Box 5 Gas Train 6 Ref. Part 500/ / /000 00/400 Qty. No. Description MBH MBH MBH MBH 3 Heat Exch.- Aluminized Sec. C34= ***A** Heat Exch. Kit- S.S. Sec. C34= ***S** Vestibule- Top Panel Vestibule- Side Panel N/S Turbulator N/S= Not shown on diagram. Aluminized Secondary Heat Exchangers are no longer available. Use the comparable Stainless Steel Secondary Kit p/n instead. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. 3 Quantity varies depending upon the size of the Heat Exchanger. For 500/640 MBH order 9 pc.; for 650/790 MBH order pc.; for 800/000 MBH order 5 pc.; for 00/400 MBH order pc. Note that the required Turbulators are NOT included in the Heat Exchanger Kits. 4 Parts detail follows this section. 5 Parts detail follows Burner section. 6 Parts detail follows Burner Control Box section. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 05

106 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules 500, 000MBH Code 34= 50***, 00*** 3 Burner 4 Burner Control Box 5 Gas Train 6 Ref. Part 500/000 Qty. No. Description MBH 3 Heat Exchanger- Aluminized Secondary C34= ***A** Heat Exchanger Kit- Stainless Steel Secondary C34= ***S** N/S Turbulator N/S= Not shown on diagram. Aluminized Secondary Heat Exchangers are no longer available. Use the comparable Stainless Steel Secondary Kit p/n instead. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. 3 Note that the required Turbulators are NOT included in the Heat Exchanger Kit. 4 Parts detail follows this section. 5 Parts detail follows Burner section. 6 Parts detail follows Burner Control Box section. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 06

107 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Diagrams Code 34= ****E*, ****R*, ****S* Burner Control Box MBH Burners Pilot Valve / Pressure Regulator Assy. Detail Housing Detail: MBH Burners RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 07

108 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Burner Housing MBH Furnace MBH Furnace Scroll MBH Furnace MBH Furnace Wheel-.5 bore, CCW MBH Furnace MBH Furnace MBH Furnace Motor MBH Furnace MBH Furnace MBH Furnace Gun Assembly 500 MBH Furnace , 650 MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube MBH Furnace MBH Furnace , 400 MBH Furnace , 000 MBH Furnace RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 08

109 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components, Continued Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Pilot Mixer MBH Furnace MBH Furnace Pilot Assembly Damper Assembly MBH Furnace MBH Furnace Blast Tube Gasket MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Right Side Damper 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 000 MBH Furnace Left Side Damper 500, 640 MBH Furnace MBH Furnace MBH Furnace MBH Furnace , 000 MBH Furnace Slide Damper 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Blower Gasket Burner Cover MBH Furnace MBH Furnace Ignition Assembly MBH Furnace MBH Furnace 0 Glass Cover Contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 09

110 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components, Continued Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL Glass Cover Support Orifice 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Clip Flange Bearing Air Switch Tube MBH Furnace MBH Furnace Pilot Burner Tube MBH Furnace , 400 MBH Furnace , 000 MBH Furnace Compression Fitting Pilot Tube Torsion Spring not used Burner Box Baffle MBH Furnace MBH Furnace Damper, Slide- Top 00 MBH Furnace not used 400 MBH Furnace not used 500 MBH Furnace not used 000 MBH Furnace not used 60 Valve- Pressure Regulator Valve- Solenoid N/S Flame Rod N/S Ignition Electrode Assy N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

111 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Diagrams Code 34= ****H*, ****T*, ****U* Detail: Orifice, Control Rod, Control Arm, Linkage, Plate RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

112 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Burner Housing MBH Furnace MBH Furnace Scroll 500 thru 800 MBH Furnace MBH Furnace Wheel-.5 bore, CCW MBH Furnace MBH Furnace MBH Furnace Motor-.5 HP, 5/60/ MBH Furnace MBH Furnace MBH Furnace Gun Assembly 500 MBH Furnace , 650 MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Inlet Funnel MBH Furnace MBH Furnace Fan Guard Blast Tube 500, 640 MBH Furnace MBH Furnace , 4000 MBH Furnace , 000 MBH Furnace RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

113 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components, Continued Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Orifice Assembly 500 MBH Furnace MBH Furnace MBH Furnace , 800 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Gasket- Blast Tube MBH Furnace MBH Furnace Air Box Assy MBH Furnace MBH Furnace Plate- Actuator Scale Gasket- Blower Panel- Burner Box Cover MBH Furnace MBH Furnace Ignition Wire Assy MBH Furnace MBH Furnace 0 Glass Cover- Burner Support- Glass Cover Grommet- Flat Box- Conduit ( MBH only) Motor- Actuator Control Arm MBH Furnace MBH Furnace Control Rod MBH Furnace MBH Furnace Crank Arm MBH Furnace MBH Furnace Contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

114 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components, Continued Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 30 Extension- Crank Arm Bushing- Control Rod Linkage Plate- Adjustable 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Until 7/ MBH Furnace 7/06 & Later MBH Furnace MBH Furnace Plate- Profile 500 MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace MBH Furnace Plate- Slide Damper 500 MBH Furnace , 650 MBH Furnace , 800, 000 MBH Furnace , 400, 500 MBH Furnace MBH Furnace Box- Air MBH Furnace Furnace Gasket- Air Box MBH Furnace Furnace Grommet Bearing- Sleeve Grommet MBH Furnace Furnace RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

115 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****E*, ****R*, ****S* Diagrams FSG Detail Gas Control Box RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

116 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****E*, ****R*, ****S* Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 00/ GV Pressure Reg. Assy Valve Only Manual Cock Valve not used Solenoid Valve not used not used Support not used 4 Flame Safeguard Subbase FSG Flame Safeguard Until 4/ Flame Safeguard 4/07 & Later Amplifier Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units Flame Safeguard T.D. 30 Sec. Modulating Burner/ETL S3 Toggle Switch- 4PST IT Ignition Transformer Air Switch- Gas Burner FLC Fan Limit Control Until 9/ Fan Limit Control 9/08 & Later TB Terminal Block- 4 Pole Jumper, Terminal Block Fitting Bushing R0 Relay Until / N/S R0A Relay /0 & Later N/S Relay Socket R3 Pilot Relay Until 5/ R3 Pilot Relay 6/08 thru / N/S R3A Pilot Relay /0 & Later, ETL only N/S Mounting Adapter N/S R3B Pilot Relay /0 & Later N/S Relay Socket N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

117 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech III Code = *E, *F, *W AND Code 34= ****E*, ****R*, ****S* Gas Control Box FSG Detail Gas Valve Detail Ref. Sch. Part Furnace MBH Qty. No. Sym. Description GV Pressure Reg. Assy Valve Only Solenoid Valve Flame Safeguard Subbase FSG Flame Safeguard Amplifier Flame Safeguard T.D. 90 Sec. UL Units Flame Safeguard T.D. 30 Sec. ETL Units S3 Toggle Switch- 4PST: S IT Ignition Transformer AS Air Switch- Gas Burner FLC Fan Limit Control TB Terminal Block Terminal Block End Stop Terminal Block End Plate Jumper Terminal R0A Relay- High Amp DPDT/0V R3A Relay- High Amp DPDT/0V R3B Relay- Low Amp DPDT/0V M9 Contactor- Motor DPDT/0V not used RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

118 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****H*, ****T*, ****U* Diagrams FSG Detail MBH Panel Detail 34 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

119 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****H*, ****T*, ****U* Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description Support Support Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit until 9/ Control- Fan Limit 9/08 & later LS/LS Switch- Limit TB Terminal Block Jumper, Terminal Block Fitting Bushing Bushing R0 Relay, 4V/DPDT N/S R0A Relay 0V /0 & Later N/S Mounting Adapter N/S R0B Relay 0V /0 & Later Relay Socket M9 Contactor- Motor not used R3 Relay- 0V/DPDT 3/0 & Earlier N/S R3B Relay- 0VSPST 4/0 & Later Relay Socket R Relay- 0V/DPDT 3/0 & Earlier R Relay- 0V/DPDT 4/0 & Later Relay Socket R Relay- 0VSPST 3/0 & Earlier R Relay- 0VSPST 4/0 & Later N/S Mounting Adapter TD0 Relay- Time Delay 0.0 Sec N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

120 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech III Code = *E, *F, *W AND Code 34= ****H*, ****T*, ****U* FSG Detail Ref. Sch. Part Furnace MBH Qty. No. Sym. Description Subbase- Flame Safeguard FSG Control- Flame Safeguard Amplifier Time Delay- Flame Safeguard S3 Switch- Toggle IT Transformer- Ignition AS Switch- Air FLC Control- Fan Limit LS, LS Switch- Limit TB Terminal Terminal Block End Stop Terminal Block End Plate R0A Relay- High Amp DPDT/0V R0B Relay- Low Amp DPDT/0V R, Relay- Low Amp DPDT/0V R3A Relay- High Amp DPDT/0V not used R3B Relay- Low Amp DPDT/0V not used M9 Relay- High Amp DPDT/0V not used Quantity varies. Determine quantity required BEFORE ordering, or contact Daikin Applied with model and serial number information so that the correct number of parts can be supplied. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

121 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train Inlet- Modulating Burner Code 34= ****E*, ****R*, ****S* Units without Pressure Regulator Valve Code 34= ****E* MBH 000 MBH Ref. Part Part Qty. No. Description Number 05 Shutoff Valve MBH Gas Valve 500 MBH MBH MBH MBH Units with Pressure Regulator Valve Code 34= ****R*, ****S* , 640, 650 or 800 MBH Furnaces 000 MBH Furnaces 00, 400 MBH Furnaces 500 MBH Furnaces 000 MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 05 Shutoff Valve Pressure Regulator 500 MBH , 650 MBH , 800 MBH MBH MBH MBH MBH MBH Gas Valve 500 MBH MBH MBH Code 34= ****R*. Code 34= ****S*. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

122 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train Inlet- Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Units without Pressure Regulator Valve Code 34= ****H* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 500 MBH MBH MBH MBH Units with Pressure Regulator Valve Code 34= ****T*, ****U* 6 3 Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 500 MBH MBH MBH Pressure Regulator 500 MBH , 650 MBH , 800 MBH MBH MBH MBH MBH MBH Code 34= ****T*. Code 34= ****U*. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

123 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Gas Train Controls GV, GV3 Code 34= ****E*, ****R*, ****S* 53 GV GV3 Ref. Part Part Qty. No. Description Number 48 Gas Valve (GV, GV3) 500 MBH MBH MBH MBH Pressure Regulator 500 MBH MBH MBH MBH Junction Box Junction Box Cover Gas Pipe Modulating Burner 500 MBH MBH , 790 MBH , 000 MBH , 400 MBH MBH MBH RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

124 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Gas Train Controls GV, GV4, GV5, GV6, GV7, GV8 Code 34= ****H*, ****T*, ****U* MBH Furnaces MBH Furnaces 00 MBH Furnaces 54 GV4 GV5 GV4 GV6 54 GV 54 GV 54 GV GV GV4 400, 500 MBH Furnaces 000 MBH Furnaces 54 GV7 GV 54 GV7 GV GV6 54 GV6 54 GV5 54 GV4 GV5 54 GV GV Ref. Part Part Qty. No. Description Number 54 Gas Valve (GV, GV4) MBH Gas Valve (GV, GV4, GV5) MBH Gas Valve (GV, GV4, GV5, GV6) 00 MBH Gas Valve (GV, GV4, GV5, GV6, GV7) 400, 500 MBH Gas Valve (GV, GV4, GV5, GV6, GV7, GV8) 000 MBH RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

125 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train- Outlet 500, 640 MBH Burners 75 Actuator & Linkage (See next page) MBH Burners 75 Actuator & Linkage (See next page) Modulating Burners Code 34= ****E*, ****R*, ****S* Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount 500 MBH MBH , 400 MBH , 000 MBH Butterfly Valve 500 MBH MBH , 000 MBH Shutoff Valve 500 MBH MBH MBH UL MBH ETL MBH MBH , 000 MBH Burners 500, 640 MBH Burners Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* Ref. Part Part Qty. No. Description Number 75 Gas Valve 500 MBH MBH MBH MBH MBH Burners 75 RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

126 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train- Modulating Burners w/ VM Actuator (09/08 & Earlier) Code 34= ****E*, ****R*, ****S* Burner Box 95 Butterfly Valve (See previous page) Ref. Part Furnace MBH Qty. No. Description , , Actuator Motor Crank Arm Ball Joint Linkage Arm Crank Arm Air Damper Lever Arm not used 3 Gas Valve Arm For units built 0/08 & Later contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

127 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat w/ 30MBH thru 000 MBH Furnace Code 04= A AND Code 34= 050***,064***,065***,079***,080***, 00***, 0***, 40*** Cabinet Doors, Gasketing, Hardware, & Flue Box Mounting Ref. Part Part Qty. No. Description Number 650 Door Assembly 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Inspection Door Assy Back- Flue Box 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Angle- Flue Box 500, 640 MBH , 790 MBH , 000 MBH , 400 MBH Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket- Inspection Door Hinge Note that individual parts of the Inspection Door Assembly are not available separately. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

128 Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat w/ 500 MBH & 000 MBH Furnace Code 04= A AND Code 34= 50***, 00*** Cabinet Doors, Gasketing, Hardware, & Flue Box Mounting Ref. Part Part No. Description Number Qty. 650 Door Assembly Inspection Door Assy Back- Flue Box Angle- Flue Box Drip Shield Sleeve Bearing Door Catch Gasket Gasket Gasket- Inspection Door Note that individual parts of the Inspection Door Assembly are not available separately. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

129 Section H- Blow-Thru Heat Blank Access Section Notes, Access Door Hardware, & Section Mounted Controls Primary Codes that pertain: 34, 38 Additional Codes that pertain: 06 Code 34 determines the Blow-thru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot= YYYYYY. Code 38 determines all of the section characteristics. If Code 38= B, F there is a 48 Blow-Thru Blank Section. If Code 38= E there is a 4 Blow-Thru Blank Section. If Code 38= Y, there is no Section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blow-Thru Heat Blank Access Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. Note that the Access Door Hardware part numbers listed below are the same for ALL RPE and RDE units regardless of the particular section s function or location EXCEPT for the Vestibule/ Access Section. See Section L for Vestibule/Access Section Door hardware. Section H pertains to the RPE, but not the RDE. Notes Access Door Latching Assemblies (All Sections) Ref. Part Part Qty. No. Description Number 0 Access Door Latching Assy., LH 4 0 Access Door Latching Assy., RH 4 N/S Sleeve Bearing N/S Door Catch N/S Gasket- Horizontal N/S Gasket- Vertical N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door s location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. If the unit is split at the Fan and Heat Sections (Code 05= F) use p/n Door Latching Assy. Left Hand Door Latching Assy. Right Hand RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

130 Section I- Blow-Thru Cooling Section Notes & Section Mounted Controls Primary Codes that pertain: 03, 35, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil (4 section for unit sizes 076 thru 00C, or normally a 48 section for unit size 0C although some units may have a 4 section installed). Small face area Coils are not available on 30 thru 50C unit sizes. If Code 03= L it is a large face area Coil (48 section for unit sizes 076 thru 00C, or 4/48 for unit sizes 0 thru 50C). Code 35 determines if there is a Section I. If Code 35= YYYY, then there is no Section. If the code is CYYY, CYYS then there is a unit Cooling Coil and Drain Pan. An S in the fourth position of this code means the Drain Pan is stainless steel. A Y in the fourth position indicates that the Drain Pan is made of painted galvanized steel. Code 36 determines Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blow-Thru Cooling Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section I pertains to the RPE, but not the RDE. Notes NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical. Section Mounted Controls LT6- Blow-Thru Cooling Section Light/S6- Blow-Thru Cooling Light Switch/ REC6- Blow-Thru Cooling Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 30

131 Section J- Final Filter Section Notes & Section Mounted Controls Primary Codes that pertain: 39 Additional Codes that pertain: 04, 33 (Mid 0 & Later), 34 Code 39 determines all of the Section characteristics. If Code 39= A, B, E, F there is a Final Filter Section with factory supplied Filters. If Code 39= C, D there is a blank/empty compartment. If Code 39= Y, there is no Section. In order for there to be a Section J, Code 34 CANNOT be YYYYYY AND Code 35 MUST be YYYY (no Blow-Thru Coil Section). Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Section J pertains to the RPE, but not the RDE. Notes Section Mounted Controls HL3 Gas Hi Limit Control: Code 04= A AND Code 39= A, B, C, D, E, F PC6 Clogged Filter Control: Code 39= A, B, E, F Control HL3 Gas Heat Hi-Limit (Firestat) Clogged Filter Pressure Switch- PC Unit Air Flow 345 Ref. Part Part Qty. No. Description Number 386 Stat Support Firestat- HL Ref. Part Part Qty. No. Description Number 345 Pressure Ctl.- PC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

132 Section J- Final Filter Section Filters 5 5A 4 4A Flat Filter Rack- Code 39= A, E Ref. Part Code Code Part Qty. No. Description 04= 5 = Number 4 Filter- 95% Eff- Cartridge High Heat 4 A, E A Filter- 95% Eff- Cartridge Standard 4 S, W A A Gasket- Filter High Heat 4 A, E A Gasket- Filter Standard 4 S, W A Filter- 95% Eff- Cartridge 3 High Heat 4 A, E A Filter- 95% Eff- Cartridge 3 Standard 4 S, W A A Gasket- Filter High Heat 4 A, E A Gasket- Filter Standard 4 S, W A If Code 5= E (Intersept) Contact Daikin Applied. Filter size= 4 x 4 x. 3 Filter size= x 4 x. 4 High Heat filters are used on units with Gas or Electric heat. Standard filters are used with Steam, HW Heat. 4 4A Staggered Filter Rack- Code 39= B, F 4 4A Ref. Part Code Code Part Qty. No. Description 04= 5 5 = Number 4 Filter- 95% Eff- Cartridge 6 High Heat 7 A, E B Filter- 95% Eff- Cartridge 6 Standard 7 S, W B A Gasket- Filter High Heat 7 A, E B Gasket- Filter Standard 7 S, W B If Code 5= F (Intersept) Contact Daikin Applied. 6 Filter size= 4 x 4 x. 7 High Heat filters are used on units with Gas or Electric heat. Standard filters are used with Steam, HW Heat. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

133 Section K- Discharge Plenum Section for RPE Units Notes Primary Codes that pertain: 08, 40 Additional Codes that pertain: 6,, 6, 34, 35, 36, 38, 39, 4. Code 08 determines the location of the Main Control Box. If Code 08= P, D the Main Control Box is located in the Discharge Plenum Section (Section K). If Code 08= C, V the Main Control Box is located in The Vestibule/Access Section (Section L). If Code 08= H, T the Main Control Box is located in the Heat Section (Section E, G). Code 40 determines the discharge direction. Options include Bottom Discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). If Code 40= BB then the unit has Bottom Discharge with Burglar Bars. If Code 40= BE, the unit has Bottom Discharge with an Isolation Damper and Actuator ACT5. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code, Disconnect Switch option, influences Access Door part numbers. Code 6 determines Smoke Detectors. If Code 6=, 3 there is a Supply Air Smoke Detector (SD). For RPE units with heat SD is in Section K. Codes 34, 35, 36, 38, 39, the Blow-thru/Final Filter Section codes, and Code 4, the Standard Service Vestibule code, pertain to some of the final assembly part numbers. Section K pertains to the RPE, but not the RDE. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 33

134 Section K- Discharge Plenum Section for RPE Units Section Mounted Controls 7 Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Unit Air Flow OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor MicroTech II MicroTech III DA Temp. Sensor MicroTech II MicroTech III DAT 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector Sensing Tube For Standard Discharge applications. For other options, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified LT5- Discharge Plenum Section Light/ S5- Discharge Plenum Section Light Switch/ REC5- Discharge Plenum Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 34

135 Section K- Discharge Plenum Section for RPE Units Isolation Damper w/ Actuator ACT5 Code 40= BE Diagrams 0/ & Earlier ACT6 Actuator Detail / & Later ACT6 Actuator Detail RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 35

136 Section K- Discharge Plenum Section for RPE Units Isolation Damper w/ Actuator ACT5 Code 40= BE Components Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized / & Earlier Isolation Damper Assy- Motorized / & Later Motor Mount Assembly / & Earlier Motor Mount Assembly / & Later Blade Assembly- Return, Angle- Linkage Angle- Blade Shaft- Damper Blade Shaft- Linkage Bearing, Flange, Nylon Actuator- Motorized- SPDT (ACT6), 0V / & Earlier Actuator- Motorized- SPDT (ACT6), 4V / & Later Crank Arm- Damper / & Earlier Crank Arm- Damper / & Later Ball Joint Bearing- Sleeve Gasket, Vinyl Bearing- Sleeve / & Later RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 36

137 Section L- Vestibule/Access Section Notes & Section Mounted Controls Codes that pertain: 08, 4, 43 Additional Codes that pertain: 06, 09 Notes Code 08 determines the location of the Main Control Box. If Code 08= V the Main Control Box is located in the Vestibule/Access Section. Inverters for the Condenser Fans (Speedtrol Inverters) are located next to the Main Control Box when Code 08= V. For Main Control Box Components and Speedtrol Inverters see Section N. Code 4, Vestibule Compartment option, is always. The Vestibule/Access Section consists of a 4 Section plus a 48 Access Section which houses the unit s Water Treatment components. Code 43 determines the characteristics of the unit s Water Treatment system and Compressor Conduit type. If Code 43= E*, the unit has no Vestibule OR Sump Heater. If Code 43= S*, the unit has a Sump Heater. If Code 43= V*, the unit has a Vestibule Heater. If Code 43= B*, the unit has both a Sump AND a Vestibule Heater. The second digit of Code 43 defines Water Treatment features and Compressor Conduit type. Refer to the Unit Model Number- Complete section of this form for more detailed information. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Vestibule/Access Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. Note that Door Hardware for Section L is DIFFERENT from the rest of the unit. Vestibule/Access Section Door Hardware is listed on the following page. Code 09, unit voltage, affects Transformers, Contactors, Motor Protectors, Pumps, and other electrical components. Section Mounted Controls LT0- Vestibule/Access Light/S0- Vestibule/ Access Light Switch/REC0- Vestibule/ Access Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture Bulb- LT Junction Box Junction Box Cover Light Switch- S Receptacle- REC RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 37

138 Section L- Vestibule/Access Section Vestibule/Access Section Door Hardware & Wall Fan Handle Detail Ref. Part Part Qty. No. Description Number Access Door Latching Assy., RH 4 3 Access Door Latching Assy., LH Fan, Wall Roller Cam Fastener, Non-Locking Fastener, Locking Mechanism Handle Locking Non-Locking (not shown) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 38

139 Section L- Vestibule/Access Section Sump Pump, Vestibule Damper, & Vestibule Heater: Code 43= B*, V* Sump Pump & Vestibule Damper Ref. Part Part Qty. No. Description Number 0 Sump Pump- Unit sizes C 08/30/ Sump Pump- Unit sizes 0-50C 08/30/ N/S Sump Pump Shaft Seal Kit Damper- Vent Intake Screen Bearing, Flange N/S= Not Shown on Diagram. Vestibule Heater 4793 Ref. Schematic Part Part Qty. No. Symbol Description Number 4793 HTR66 Heater- Vestibule Code 43= B*, V* RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 39

140 Section L- Vestibule/Access Section Water Treatment Controls without Water Make-Up Ref. Schematic Part Part Qty. No. Symbol Description Number 59 Valve, Water 7/8 ODS ACT64 Actuator- Purge Valve, Water 3/4 FPT Valve, Water 7/8 ODS Valve, Water- Drain 3/4 FPT Valve, Water 3/4 FPT ACT6 Actuator- Sump Fill Water Treatment Pipe Coil- Sump /07 & Earlier /07 & Later Dolphin T Transformer- Sump /07 & Earlier 0530 /07 & Later Dolphin CTL Conductivity Control /07 & Earlier 0530 /07 & Later Electrical Box Receptacle- GFCI Cover, Electrical Box Cyclone Centrifugal Separator Pressure Gauge 0-30 psi Valve, Water /07 & Earlier FPT 5730 /07 & Later 3/4 FPT ACT6 Actuator- Blowdown The above diagrams show standard component layouts. Not all components are used in every situation. Visually confirm the piping configuration and component placement before ordering or, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Note that the Make Up Water option was first offered in 009. On 08/0 the original Actuator p/n 0540 was discontinued and replaced with functional replacement p/n Overall dimensions differ slightly, but function is equivalent. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 40

141 Section L- Vestibule/Access Section Water Treatment Controls with Water Make-Up Ref. Schematic Part Part Qty. No. Symbol Description Number 50 Valve, Water 3/4 FPT ACT6 Actuator- Blowdown Valve, Water 7/8 ODS ACT64 Actuator- Purge Valve, Water 3/4 FPT Valve, Water 7/8 ODS Valve, Water- Drain 3/4 FPT Valve, Water 3/4 FPT Water Treatment Pipe Coil- Make Up Water ACT6 Actuator- Sump Fill Water Treatment Pipe Coil- Sump Dolphin T Transformer- Make Up Water Dolphin T Transformer- Sump Dolphin CTL Conductivity Control /07 & Earlier 0530 /07 & Later Cyclone Centrifugal Separator Pressure Gauge 0-30 psi Valve, Water 3/4 FPT ACT63 Actuator- Auto System Drain The above diagrams show standard component layouts. Not all components are used in every situation. Visually confirm the piping configuration and component placement before ordering or, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Note that the Make Up Water option was first offered in 009. On 08/0 the original Actuator p/n 0540 was discontinued and replaced with functional replacement p/n Overall dimensions differ slightly, but function is equivalent. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

142 Section M- Condenser Section Notes Primary Codes that pertain: 4, 43, 44, 45, 47 Additional Codes that pertain: 09, 0 Code 4 affects Compressor capacity control. This code determines the number of Compressor unloaders specified. Note that replacement compressors are shipped with maximum unloading capability. Code 43 determines the characteristics of the unit s Condenser options and Compressor Conduit type. Refer to the Unit Model Number- Complete section of this form for more detailed information. Code 44 determines the Compressor refrigerant used. Code 44= H indicates R and Code 44= K specifies R407C. Note that ALL Evaporative Condensing units use Semi Hermetic Discus Compressors. Code 45 determines the way the Compressors are mounted. Code 47 determines the Inverter vendor for low ambient operation. Code 47= A means that ABB Inverters were specified. Code 47= G indicates Graham/DanFoss brand Inverters were installed. Code 47= Q shows Schneider Inverters were furnished. Code 47= R shows Reliance brand Inverters were chosen. Code 47= B, S indicates that Daikin Applied brand Inverters were used. Note that ALL Evaporative Condensing units are equipped for low ambient operation (Code 47 CANNOT = Y). Code 09, Unit voltage, & Code 0, Compressor starting options, affect Compressor, Compressor Contactor, and Condenser Motor selection. For Main Control Box components see Section N. For refrigeration components see Section O. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

143 Section M- Condenser Section Sump Water Temp. Sensor SWT, Water Level Switches WL63, WL64, & Sump Heater HTR65 Code 43= B*, S* 0A 0B 6 Ref. Schematic Part Part Qty. No. Symbol Description Number SWT Sensor- Sump Water Temperature MicroTech II (Code = *D, *S) MicroTech III (Code = *E, *F, *W) A WL63 Switch- Level 09/08 & Earlier /08 & Later B WL64 Switch- Level 09/08 & Earlier /08 & Later HTR65 Heater- Sump (Code 43= B*, S*) The Sensor for this Level Switch CANNOT be ordered separately. If the Switch s Sensor fails, the Switch must be replaced. This Switch is normally open (NO) in the dry position. To make it a normally closed (NC) valve, rotate the Switch Assembly 80 degrees to change the Switch logic from NO to NC. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 43

144 Section M- Condenser Section Fan Deck Assembly- Diagrams Fan Deck Assy C Fan Deck Assy. 0-50C Fan Motor Mounting Detail Condenser Fan Arrangement Fan # Fan # Fan #3 Fan # Fan # Fan # Fan # Fan #3 Fan # Fan # RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 44

145 Section M- Condenser Section Fan Deck Assembly- Components Ref. Part Part Unit Size No. Description Number Panel, Fan Shroud /04 & Before /05 & Later Guard, Fan Screw, Tapping Motor, Fan 08/30/ Motor, Fan Prop, Fan A different motor was used in units built 005 & Earlier. Motor 300 is the specified replacement for ALL 08- Condenser Fans regardless of build date. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 45

146 Section M- Condenser Section Condenser Coils A Ref. Part Part Unit Size No. Description Number , A Coil, Evaporative Condenser Coil, Evaporative Condenser Coil, Evaporative Condenser Spray Nozzle Contact Daikin Applied with model and serial number information so that the correct coil can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 46

147 Section M- Condenser Section Compressor Layout Diagrams Two Compressor Layout C Compressor # Compressor # Four Compressor Layout 0-50C Compressor #4 400 #4 Compressor # 00 #3 # # 300 Compressor #3 00 Compressor # RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 47

148 Section M- Condenser Section Compressors Unit Size Ref. Part Part No. Description Number 4 Compressors 5HP R 0 or unloader or unloader HP R407C 3 0 or unloader or unloader / 08/ 08/ 08/ 08/ 08/ 30HP R 0- unloaders unloaders or unloader or unloader HP R407C 3 0 or unloader or unloader or unloader or unloader HP R 0- unloaders unloaders HP R407C 3 0- unloaders unloaders HP R 0- unloaders unloaders unloaders HP R407C 3 0- unloaders unloaders unloaders For units (Code 09= 37) contact Daikin Applied so that the correct compressor(s) can be identified. Note that starting early in 0 there was a vendor change in the Compressors. Compressors built 0 and later utilize a CoreSense Controller and related components. Replacement Compressors will NOT come equipped with a Controller; therefore the Controller from the previous Compressor will need to be reused. If the CoreSense Controller needs to be replaced, contact Daikin Applied for more information. Code 44= H. 3 Code 44= K. 4 For unit size 40C: Compressors Ref. # 00 & 00 are 30HP, and Compressors Ref. # 300 & 400 are 35HP. 5 All 4 cylinder compressors 30HP and smaller are equipped with one Unloader and all 30-40HP 6 cylinder Compressors are equipped with two Unloaders. Note that ALL Compressors come with maximum unloading capacity standard. If a replacement Unloader is needed, refer to the following page. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 48

149 Section M- Condenser Section Compressor Components 4 K J L H M N P G Oil Equalization Detail Unit Size Ref. Part Part No. Description Number G Crankcase Heater Liquid Tite Conduit Flex Conduit All Conduits H High Pressure Control J Valve- Unloader K Gasket- Unloader L Gasket M Low Pressure Control N Valve- Oil Equalization P Cap- Oil Equal. Valve Code 43= D, *F, *J, *L, *N. Code 43= *E, *H, *K, *M, *Y. 3 Quantity of Unloader Valve is as required. There are Gaskets PER Valve. Note that ALL Compressors come with maximum unloading capacity standard. Order replacement parts as needed. 4 For Suction and Discharge Service Valves see Refrigeration Tubing Section (Section O). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 49

150 Section M- Condenser Section Compressor Mounting Resilient Mount (Code 45= ) Ref. Part Comp. Part Qty. No. Description HP Number 4 Channel- Rubber Mount All Spacer Pad- Lower All Spacer Pad- Upper All Spacer- Rubber All Screw- Cap, 3/8-6 X All Nut- Hex, Flanged All Bolt- Hex 5/8- X.75 All Nut- Hex, 5/8- All Washer- Flat, 5/8 All Spring Mount (Code 45= ) Ref. Part Comp. Part Qty. No. Description HP Number 4 Channel- Spring Mount All Spring Isolator Kit Spring Isolator Kit 5, Spring Isolator Kit Spring Isolator Kit Screw- Cap, 3/8-6 X All Nut- Hex, Flanged All Kit contains 4 Springs. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 50

151 Section N- Controls Notes Primary Codes that pertain: 08, 09,,, 3, 4, 5, 7, 8 Additional Codes that pertain: 04, 0,, 3, 34, 40, 47 There have been four generations of Main Control Boxes offered:. The original MicroTech II Control Box (Code 08= P, S AND Code = *D, *S) was used from the start of production in 004 until the end of March, 005. This Control Box had the Main Processor (MCB) mounted in the Control Panel with the Keypad mounted in the Dead Front Door.. The redesigned MicroTech II Control Box (Code 08= V AND Code = *D, *S) was used April, 005 until the end of December, 00. There is a MCB as well as two Compressor Control Boards (CCB, CCB) in the Control Box. In January, 007 a vendor change was made for Contactors, MMPs, Relays, and related components. Form and function are identical, however these components and related accessories are NOT directly interchangeable. 3. The MicroTech III (Code 08= V AND Code = *E, *F, *W) Control Box was introduced in January, 0. The Controller (MCB) changed and the Compressor Control Boards were replaced with Expansion Modules (EXPA- D), however the majority of components are the same as the later MicroTech II design. 4. In May of 03 the entire MicroTech III Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and Inverter circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable with any previous design. Code 08 determines the location of the Main Control Box. If Code 08= V the Main Control Box is located in the Vestibule/Access Section (Section L). If Code 08= P, S, the Main Control Box is located in the Supply Air/Discharge Plenum Section (Section F). Components are the same in both cases. Code 9, unit voltage, affects Transformers, Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch. Code selects the unit s control type (MicroTech version), communication protocol, and whether the unit is set up for Discharge Air, Space Control, or Zone control. Evaporative Condensing units MUST be sold with MicroTech Controls. Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine Supply and Return Air Inverter options. For Inverter part numbers refer to the Supply Air Section (Section F). Code 7 determines whether the unit is equipped with a PVM (Phase Voltage Monitor), Freezestat, UV Lights, Ground Fault Protection, and/or Line Reactors. Code 8 indicates whether a unit has a Remote Keypad Display, Unit Powered Receptacle, and/or a Modem. Codes 04 and 34 determine the heat type, which impacts Transformers and Heating/Cooling Circuit Relays. Codes 0, are Return Air codes that impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc. have an impact on Contactors, Overloads/MMPs, Fuses, and Duct Sensors. Code 3 determines horsepower of the Supply Air Fan Motor which, like the Return Air Motor, affects Contactors, Fuses, Overloads/MMPs, etc. Code 40 determines if there is an Isolation Damper and associated Relay. Code 47 determines Condenser Fan Inverter selection. Inverters for the Condenser Fans are located next to the Main Control Box. Note that ALL Evaporative Condensing units are set up for Low Ambient operation (Code 47 CANNOT = Y). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

152 Section N- Controls MicroTech II Controls: Code = *D, *S Unit Control Layout Diagram- 3/05 & Earlier Speedtrol Inverter/VFD (AFD/VFD) Main Control Box Electronic Control Panel Condenser Control Box Deadfront Door Keypad Display Power Panel Main Disconnect (DS) Compressor Control Box Control/Switch Panel Oil Pressure Box The above diagram shows a typical Unit Control layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

153 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Layout Diagram See Power Panel Section The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and Control Box configuration may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 53

154 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Components Sch. Part Part Qty. Sym. Description Number Switches S Toggle Switch- Control: Units with Gas Heat (Code 04= A) Toggle Switch- Control: Units w/o Gas Heat (Code 04= E, W, S, Y) S4, S5 Toggle Switch- Inverters (Code 4= - 9) Connector Bar- Inverter on Supply and Return Air Fan S7 Rocker Switch- On/Off PS3 Pumpdown Switches- Refrigeration Circuits Fusing F Fuseholder- Control Circuit Fuse- Control Circuit F3 Fuse Block- Gas Heat Units Fuse, Gas Heat Units: MBH furnaces Fuse, Gas Heat Units: MBH furnaces Receptacle REC Receptacle- GFI Receptacle- Std. 5A Terminal Blocks TB Terminal Block- 30 Terminals TB3 Terminal Block- 30 Terminals TB4 Terminal Block- 0 Terminals TB5, 6 Terminal Block, 4 Terminals TB0 Terminal Block- Terminals: Electric, Gas Heat (Code 04= E, A) Terminal Block- Terminals: Hot Water, Steam, No Heat (Code 04= W, S,Y) 043 NB, Terminal Block- Neutral Block Transformers T, T3 Transformer- Control Circuit T9 Transformer- Refrigerant Circuit Relays R, Relay- High Pressure Reset R3, 4 Relay- High Pressure R0 Relay- Gas, Steam, Hot Water Heat (Code 04= W, S, A) R4 Relay- Gas Heat R5 Relay, Gas Heat: Units with Inverters (Code 4= - 9) R6 Relay- Iso Damper R8 Relay- Isolation Damper (Code 40= BE OR Code 9= BE) R45 Relay- UV Lights R46,47 Relay- Supply Fan R48,49 Relay- Exhaust Fan Inverter R64 Relay- Sump Pump R67 Relay, Control: units with inverters (Code 4= - 9) Relay, Control: units w/o inverters (Code 4= Y) R68 Relay- Return Fan w/ Inverter or Exhaust Fan Relay- Return Fan w/o inverter R69 Relay- Inverters w/ Bypass (Code 4=,, 3, 4, 5, 8) TD3, 4 Relay, Time Delay- High Pressure Not Shown on diagram. Relay Assembly. Consists of: Relay- p/n ; Socket Only- p/n ; Clip Only- p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 54

155 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Components, Continued Sch. Part Part Qty. Sym. Description Number MicroTech II Controller and Associated Boards MCB Main Control Board CCB, Auxiliary Cooling Control Board 060 Fuse, Auxiliary Cooling Control Board 0650 Com Module- Bacnet MSTP (RS-485) (Code = B*) Standoff- RS-485 Comm Module Com Card- Bacnet with Ethernet (Code = E*) Com Card- LonMark with Space Control (Code = LS) Com Card- LonMark with Discharge Control (Code = LD) Standoff- Com Card Kit- Connector Repair PWR Power Supply 5VDC Serial Port Ribbon Cable 0470 Battery EHB Electric Heat Board (Code 04= E) 060 Standoff EHB Communication Module Standoff- Comm Module Keypad Keypad Assy. (Code 9= R, Y) Board- Remote Keypad Interface (Code 9= R) 060 Cable- Keypad MicroTech II Remote Keypad Kit Transducers and Pressure Controls SPS Static Pressure Transducer- Duct/Building (Code 3=,, 3) SPS Static Pressure Transducer- Duct (Code 3= ) Static Pressure Transducer- Building (Code 3= 3, 4) DHL Duct Hi-Limit Pressure Control Pressure Fitting- DHL Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Termp. w/ Tenant Override & Remote Setpoint Adjustment, DAT Sensor- Discharge Air Temperature ENT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. Not Shown on diagram. 3 SCC Units only- Code = BS, LS, ES, SS. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 55

156 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Diagram The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 56

157 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components Sch. Part Part Voltage Sym. Description Number Disconnect Switch (Code = A, B, C, D) DS, Disconnect Switch 60A/600V Handle Mechanism- 60A Switch Disconnect Switch 00A/600V Handle Mechanism- 00A Switch Disconnect Switch 50A/600V Handle Mechanism- 50A Switch Disconnect Switch 400A/600V- inlet holes Handle Mechanism- 400A Switch Disconnect Switch 400A/40V- inlet holes Handle Mechanism- 400A Switch Disconnect Switch 400A/600V- inlet hole Handle Mechanism- 400A Switch Disconnect Switch 400A/40V- inlet hole Handle Mechanism- 400A Switch Disconnect Switch 600A/600V Handle Mechanism- 600A Switch Disconnect Switch 800A/600V- inlet holes Handle Mechanism- 800A Switch Disconnect Switch 800A/600V- inlet hole Handle Mechanism- 800A Switch 0306 Disconnect Switch 00A/600V Handle Mechanism- 00A Switch The Disconnect Switch used on a given unit is contingent upon unit voltage, Motor horsepower, and other options. Check the part in the unit to size up the replacement, or contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that DS is used only when Code = B, C, D. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 57

158 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 0 Horsepower Motor- Code OR 3= N** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse- FB0 OR FB Fuse- FB0 OR FB0 80A, 600V Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 58

159 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 40 Horsepower Motor- Code OR 3= R** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Contactor- Supply (M0), Return (M0) Fan Motor Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse- FB0 OR FB Fuse- FB0 OR FB0 80A, 600V Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 59

160 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 50 Horsepower Motor- Code OR 3= S** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse- FB0 OR FB Fuse- FB0 OR FB0 00A, 600V Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 60

161 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Control/Switch Panel Sch. Part Part Qty. Sym. Description Number CS, Switch- Control Stop PS, Switch- Pumpdown REC Receptacle- GFI The above diagram shows a typical Control/Switch Panel layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

162 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Condenser Control Box- Diagrams The above diagram shows a typical four Fan Condenser Control Box layout (sizes C) and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size, and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

163 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Condenser Control Box- Components Unit Sizes Sch. Part Part Sym. Description Number Transformer T Transformer- Main Transformer- Main, Gas Heat (Code 04= A) Transformer- Main, No Heat (Code 04= Y) Fuse Blocks & Fuses FB8 Fuse Block- T Transformer P, 30A Fuse- FB8 Fuse Block Fuse- FB8 Fuse Block, Gas Heat (Code 04= A) Fuse- FB8 Fuse Block, No Heat (Code 04= Y) FB, Fuse Block- Condenser Fan Fuse- FB, FB Fuse- FB, FB 5A, 600V FB, 3 Fuse Block- Condenser Fan Fuse- FB, FB Fuse- FB, FB3 5A, 600V FB64 Fuse Block- Water Pump Fuse- FB64 5A, 600V FB65 Fuse Block- Sump Heater Fuse- FB65 5A, 80V Terminal Block TB Terminal Block- Receptacle 6P, 0A Phase Voltage Monitor PVM Phase Voltage Monitor Overloads OL,, OL, Overload- Condenser Fans OL3, 3 Overload- Condenser Fans 3 OL64 Overload- Water Pump 3 Heater- Cond. Fan/Water Pump Overload Contactors M, Contactor- Condenser Fan Motor M3, 3 Contactor- Condenser Fan Motor M64 Contactor- Water Pump Phase Voltage Monitor is used when Code 7= *P, *A, *C, *D, *H, *J, *K. Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 3 Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 63

164 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Compressor Control Box- Diagram The above diagram shows a typical four Compressor Control Box layout (sizes 0-50C) and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 64

165 Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Compressor Control Box- Components 08/ Unit Size / 08/ 08/ 08/ 08/ 08/ Sch. Part Part Sym. Description Number Fuse Blocks & Fuses FB, Fuse Block- Compressor Fuse Block- Compressor Fuse Block- Compressor Fuse- FB OR FB Fuse- FB OR FB 80A FB3, 4 Fuse Block- Compressor Fuse Block- Compressor Fuse Block- Compressor Fuse- FB OR FB Fuse- FB OR FB 60A Fuse- FB OR FB 80A Contactors M, Contactor- Compressor Contactor- Compressor 60A Contactor- Compressor 50A M3, 4 Contactor- Compressor Contactor- Compressor 50A Contactor- Compressor 60A There is one component PER compressor. Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 65

166 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Diagram The above diagram shows a typical four compressor (size 0-50C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 66

167 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller Com Card- Bacnet (Code = B*) Com Card- Bacnet with Ethernet (Code = E*) Com Card- LonMark Space Control (Code = LS) Com Card- LonMark Discharge Control (Code = LD) Standoff- Com Card Kit- Connector Repair Serial Port Ribbon Cable 0470 Battery Grounding Bar Keypad Keypad Keypad Remote Keypad Interface Board 060 Cable- Interface Compressor Controller CCB, Expansion Board- Compressor Controller 060 Fuse- Expansion Board 0650 Standoff- Expansion Board Comm. Card- Bacnet Standoff- Comm. Card RES Resistor- CCB Electric Heat Board EHB Expansion Board- Electric Heat 060 Standoff- Expansion Board Expansion Board Comm. Card- Bacnet Standoff- Comm. Card Switches- Control HS Switch- Electric Heat Shutdown (Code 04= E) PS, Switch- Pumpdown CS, Switch- Control S Switch- System On/Off Gas Heat Units (Code 04= A) Elec.,Steam,HW, No Heat (Code 04= E,S,W,Y) S4 Switch- Inverter Bypass On/Off S7 Switch- Local On/Auto/Off to Controller Serial Cables Serial Serial Cable 0470 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS Pressure Transducer- Duct Sensor (Code 3=,, 3) SPS Pressure Transducer- Duct Sensor (Code 3= ) Pressure Transducer- Space Sensor (Code 3= 3, 4) This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 67

168 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R, Relay- Hi Pressure Reset R3, 4 Relay- Hi Pressure Delay R5.,5. Relay- Safety R6.,6. Relay- Safety R7., 7. Relay- Safety R8., 8. Relay- Safety R9, 0 Relay- Compressor Lockout R, Relay- Speedtrol Fan Cycling (Code 47= ) R3.,3. Relay- Safety R4.,4. Relay- Safety R8, 9 Relay- Cooling Failure Indicator R0 Relay- Steam or Hot Water Heat (Code 04= S, W) Relay- Electric Heat (Code 04= E) Relay- Gas Heat (Code 04= A) Hi Turn Down Burner (Code 34 [Digit 5]= H, T,U) Modulating Burner (Code 34 [Digit 5]= E, R, S R4 Relay- Gas Heat Alarm (Code 04= A) R5 Relay- Gas Heat, Start Supply Fan Inverter (Code 4=,,3,5,6,7) R6 Relay- Isolation Damper- Open/Close R8 Relay- Isolation Damper Safety R30 Relay- Cool Valve w/ Face Bypass R45 Relay- UV Lights R46 Relay- Inverter, Supply Fan increase/decrease (Code 4= -3,5-7) R48 Relay- Inverter, Return Fan increase/decrease (Code 4=,4,5,7-9) R6 Relay- Discharge Air Smoke Detector R63 Relay- Specials R64 Relay- Sump Pump R66 Relay- Return Air Smoke Detector (Code 6=, 3) R67 Relay- Supply Fan Enable R68 Relay- Return Fan Enable R69 Relay- Inverter Bypass VAV Interlock (Code 4= - 9) R70 Relay- Specials All R0 options are detailed here but for units with Gas Heat (Code 04= A), R0 is located in the Gas Heat Control Box (see Section G). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 68

169 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Qty. Sym. Description Number Time Delays TD Time Delay- Compressor Lockout 300 Sec TD Time Delay- Compressor Lockout 300 Sec TD3 Time Delay- Hi Pressure 5 Sec TD4 Time Delay- Hi Pressure 5 Sec TD Time Delay- Low Ambient 65 Sec TD Time Delay- Low Ambient 65 Sec Transformers- Controls T Transformer- Control Input 5-4V T3 Transformer- Control Output 5-4V T4 Transformer- Exhaust Damper Actuator 5- VDC T9 Transformer- Refrigerant Circuit 4V Terminal Blocks TB Terminal Block- Internal Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 0480 DAT Sensor- Discharge Air Temperature ENT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature Plugs Pin Plug varies 6 6 Pin Plug varies 7 Pin Plug varies 8 3 Pin Cap Kit varies 9 6 Pin Cap Kit varies 0 9 Pin Cap Kit varies 5 Pin Cap Kit varies SCC Units only- Code = BS, LS, ES, SS. Not Shown on diagram. 3 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n All possible Plugs used are listed. Check actual unit to verify which Plug is required. Not shown on diagram. 5 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 6 Used with Strain Relief (p/n ) & 6 pin Cap Kit (p/n ). Used for PL0, PL. 7 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 8 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 9 Used for PL9, PL0. 0 Used for PL8, PL9, PL35, PL36, PL43. Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 69

170 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Terminal Blocks TB Terminal Block- Field TB3 Terminal Block- Factory TB4 Terminal Block- Field TB7 Terminal Block- Field Convenience Outlet Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights.5KVA Units without UV Lights.5KVA Gas Heat (Code 04= A) Units without UV Lights.5KVA Units without UV Lights.5KVA Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights 0A Units without UV Lights 5A Units without UV Lights 8A Units without UV Lights 7A Gas Heat (Code 04= A) Units without UV Lights 5A Units without UV Lights A Units without UV Lights 9A FC Fuse- T Transformer,Secondary F3 Fuse- Burner Blower Motor (Code 04= A) Fuse Block Fuse mbh furnace Fuse mbh furnace Fuse Cover PWR Power Supply Board 5VDC Ground Fault Protection (Code 7 [Digit ]= G,B,C,D,K) GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A MMP64 Motor Protector- Water Pump 4-6.3A Motor Protector- Water Pump.5-4.0A Motor Protector- Water Pump.6-.5A Spacer Link M65 Contactor- Sump Heater 3A Contactor- Sump Heater A Contactor- Sump Heater 7.5A FB65 Fuse Block- Sump Heater Fuse 5A Fuse 0A Fuse A Fuse 0A Fuse Guard Varies depending on unit options. Part number is for one individual section. Ground block is p/n For units with UV Lights (Code 7, Digit = - 9) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 70

171 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Phase Voltage Monitor (Code 7 [Digit ]= P,A,C,D,H,J,K) PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Power Blocks PB, PB Power Block- Main (Code = P, Q) Power Block- 75A Cover- 75A Block Lug- 75A Block Power Block- 55A Cover- 55A Block Lug- 55A Block Power Block- 380A Cover- 380A Block Lug- 380A Block Power Block- 40A Cover- 40A Block Lug- 40A Block Power Block- 60A Cover- 60A Block Lug- 60A Block Power Block- 760A Cover- 760A Block Lug- 760A Block Power Block- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 75A Cover- 75A Block Power Block- 30A Cover- 30A Block Power Block- 40A Cover- 40A Block Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat , 80, 00 KW Electric Heat , 80, 00 KW Electric Heat KW Electric Heat , 60 KW Electric Heat , 40, 80, 30 KW Electric Heat PB0 Power Block- Supply Fan (Code 5= F) PB0 Power Block- Return Fan (Code 5= F) Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB is installed when code = Q. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

172 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Receptacle REC Receptacle Disconnect Switch DS Disconnect Switch- Main (Code = A, C, D) DS Disconnect Switch- RAF/SAF (Code = C, B, D) Switch- 00A, Lugs Lug Handle Ground Lug Switch- 50A Lugs Handle Ground Lug Switch- 50A Lugs Handle Ground Lug Switch- 400A Lugs Handle Ground Lug Switch- 600A Lugs Handle Ground Lug Switch- 800A Lugs Handle Ground Lug Switch- 00A, Lugs Handle Ground Lug Any of the listed disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. The Lug quantites listed are for the DS. DS use ½ the quantity plus an additional Lug: 50A Lug p/n ; 50A Lug p/n ; 400A Lug p/n TACL40PD3; 600A Lug p/n DS only. 4 DS only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

173 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Detail Motor Horsepower 5 thru 5 Lugs Circuit Breaker 3 Plug Voltage Ref. Sch. Part Part No. Sym. Description Number Lugs CB0 Circuit Breaker- Supply Fan CB0 Circuit Breaker- Return Fan Motor HP= 5, Motor HP= 0, Motor HP= 0, Motor HP= 0, Motor HP= 0, Motor HP= Motor HP= Plug- Rating Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Circuit Breakers are only used when a Fan Motor has an Inverter (Code 4= - 9). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 73

174 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Detail Motor Horsepower 30 thru 75 Lugs Circuit Breaker 3 Plug Voltage Ref. Sch. Part Part No. Sym. Description Number Lugs CB0 Circuit Breaker- Supply Fan CB0 Circuit Breaker- Return Fan Motor HP= Motor HP= Motor HP= 30, Motor HP= Motor HP= 40, Motor HP= 30, 40, Motor HP= 60, Plug- Rating Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Circuit Breakers are only used when a Fan Motor has an Inverter (Code 4= - 9). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 74

175 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Short Circuit 3C Alarm Aux. Contact NO/NC Aux. Contact 3D D MMP 3 Line 3A Shield 3B Link Contactor A Cover Short Circuit Alarm 3C NO/NC Aux. Contact D 3 MMP 3E 3B Front Mounted Contact Link Contactor A Cover MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- All Voltages 7.5 HP Motor- 30/460/ 0, 5 HP Motors- 460/ MMP0 & M0 Link Detail MMP0 & M0 Link Detail 7.5 HP Motors- 0, 5 HP Motors- 08/ 0, 5, 30 HP Motors- 460/ 40 HP Motors- 3 MMP 3E Front Mounted Contact 3G Lug 3 MMP 3G 3 Lug MMP Short Circuit Alarm 3C Contactor NO/NC Aux. Contact D 3F Trip Ind. Interlock Contactor 3F Trip Ind. Interlock 3G Lug NO/NC Aux. Contact D Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0 HP Motors- 08/ 5 HP Motors- 40 HP Motors- 50 HP Motors- 460/ 60 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30 HP Motors- 08/ 40 HP Motors- 60 HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 40 HP Motors- 50 HP Motors- 08/ 60 HP- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 75

176 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 5 HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Line Shield B Link Link C Short Circuit Alarm D Aux. Interlock- NO/ NC HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Line Shield B Link Link Link C Short Circuit Alarm D Aux. Interlock- NO/ NC E OL Circuit Alarm- Front RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 76

177 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor Cover- Contactor Cover- Contactor MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan A Line Shield B Link Link Link C Short Circuit Alarm D Aux. Interlock- NO/ NC E OL Circuit Alarm- Front HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor Cover- Contactor MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan A Line Shield B Link Link C Short Circuit Alarm D Aux. Interlock- NO/ NC E OL Circuit Alarm- Front RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 77

178 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link C Short Circuit Alarm E OL Circuit Alarm- Front HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link C Short Circuit Alarm E OL Circuit Alarm- Front F Trip Indicator Interlock G Lug (3 per kit) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 78

179 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 30 HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link C Short Circuit Alarm E OL Circuit Alarm- Front F Trip Indicator Interlock G Lug (3 per kit) HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan A Cover- Contactor MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link C Short Circuit Alarm E OL Circuit Alarm- Front F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 79

180 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan C Short Circuit Alarm E OL Circuit Alarm- Front F Trip Indicator Interlock G Lug (3 per kit) Also requires 3 field supplied ring terminals. 60 HP Motor- Code 3 OR 3 = T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan C Short Circuit Alarm E OL Circuit Alarm- Front F Trip Indicator Interlock G Lug Also requires 3 field supplied ring terminals. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan MMP0 MMP- Supply Fan F Trip Indicator Interlock G Lug RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 80

181 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Diagrams Short Circuit 3C Alarm Aux. Contact NO/NC Aux. Contact 3D D NO Front Aux. Contact MMP 3 Line 3A Shield 3B C Link MMP- 4 & M- 4 Link Detail 0C- Contactor A Cover B NC Front Aux. Contact Short Circuit Alarm 3C NO/NC Aux. Contact D NO Front Aux.Contact 3 MMP C 3E 3B Front Mounted Contact Link Contactor A B MMP- 4 & M- 4 Link Detail 076C, 30C- All Voltages 089C- 30/460/ 00C- 0C- 08/30/ 40C Cir. #- All Voltages 40C Cir. #- 30/460/ 50C- 30/460/ Cover NC Front Aux. Contact 3 MMP 3E Front Mounted Contact 3G Lug 3 MMP Short Circuit Alarm 3C Contactor NO/NC Aux. Contact D 3F Trip Ind. Interlock Contactor NO/NC Aux. Contact D NO Front Aux. Contact C B NC Front Aux. Contact MMP- 4 & M- 4 Link Detail 089C- 00C- 30/ 40C Cir. #- 50C- NO Front Aux. Contact C B NC Front Aux. Contact MMP- 4 & M- 4 Link Detail 00C- The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

182 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 80A Contactor 68A Contactor 6A Contactor 48A A Cover- Contactor B Aux. Contact, Front- NC C Aux. Contact, Front- NO Compressor MMP s & Parts 3 MMP, Manual Motor Protector 63-00A Manual Motor Protector 50-63A Manual Motor Protector 40-50A Manual Motor Protector 5-40A B Link C Short Circuit Alarm E Front Mounted Contact- NO F Trip Indicator G Lug Kit (3 lugs per kit) RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

183 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components, Continued Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 6A Contactor 48A Contactor 3A A Cover- Contactor Cover- Contactor B Aux. Contact, Front- NC Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector 40-50A Manual Motor Protector 5-40A Manual Motor Protector 4-3A A Line Shield B Link C Short Circuit Alarm D Front Mounted Contact- NO/NC E Front Mounted Contact- NO RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 83

184 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components, Continued Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 68A Contactor 6A Contactor 48A M3, 4 Contactor 68A Contactor 6A Contactor 48A A Cover- Contactor Compressor MMP s & Parts 3 MMP, Manual Motor Protector 50-63A Manual Motor Protector 40-50A Manual Motor Protector 5-40A MMP3, 4 Manual Motor Protector 50-63A Manual Motor Protector 40-50A Manual Motor Protector 5-40A B Link C Short Circuit Alarm E Front Mounted Contact- NO For unit size 40C, M, & MMP, are for the 30HP Compressors; M3, 4 & MMP3, 4 are for the 35HP Compressors. 4pc. used on Circuit # only. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 84

185 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3A Line Shield 6 Lugs Short Circuit Alarm 3C 3B Link 5 Circuit Breaker Spacer 4 Contactor 7 Plug Unit Size Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A M3, 3 Contactor- Condenser Fan 9A Fan MMP s & Parts 3 MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP3, 3 Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A A Line Shield- MMP B Link- MMP C Short Circuit Alarm- MMP Spacer- Contactor Fan Circuit Breaker & Parts 5 CB Circuit Breaker- Condenser Fan Lugs- Circuit Breaker Plug- Circuit Breaker Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 85

186 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Diagram The above diagram shows a typical four compressor (size 0-50C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 86

187 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 87

188 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller Com Card- Bacnet (Code = B*) Com Card- Bacnet with Ethernet (Code = E*) Com Card- LonMark Space Control (Code = LS) Com Card- LonMark Discharge Control (Code = LD) Standoff- Com Card Kit- Connector Repair Power Supply- 5 VDC Serial Port Ribbon Cable 0470 Battery Grounding Bar Keypad Keypad Keypad Remote Keypad Interface Board 060 Cable- Interface Compressor Controller CCB, Expansion Board- Compressor Controller 060 Fuse- Expansion Board 0650 Standoff- Expansion Board Comm. Card- Bacnet Standoff- Comm. Card RES Resistor- CCB Electric Heat Board EHB Expansion Board- Electric Heat 060 Standoff- Expansion Board Expansion Board Comm. Card- Bacnet Standoff- Comm. Card Switches- Control HS Switch- Electric Heat Shutdown (Code 04=E) PS, Switch- Pumpdown CS, Switch- Control S Switch- System On/Off Gas Heat Units (Code 04= A) Elec.,Steam,HW, No Heat (Code 04= E,S,W,Y) S4 Switch- Inverter Bypass On/Off S7 Switch- Local On/Auto/Off to Controller Serial Cables Serial Serial Cable 0470 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS Pressure Transducer- Duct Sensor (Code 3=,, 3) SPS Pressure Transducer- Duct Sensor (Code 3= ) Pressure Transducer- Space Sensor (Code 3= 3, 4) This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 88

189 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R, Relay- Hi Pressure Reset R3, 4 Relay- Hi Pressure Delay R5., 5. Relay- Safety R6., 6. Relay- Safety R7., 7. Relay- Safety R8., 8. Relay- Safety R9, 0 Relay- Compressor Lockout R, Relay- Speedtrol Fan Cycling (Code 47= ) R3.,3. Relay- Safety R4.,4. Relay- Safety R8, 9 Relay- Cooling Failure Indicator R0 Relay- Steam or Hot Water Heat (Code 04= S, W) Relay- Electric Heat (Code 04= E) Relay- Gas Heat (Code 04= A) Hi Turn Down Burner (Code 34 [Digit 5]= H,T, U) Modulating Burner (Code 34 [Digit 5]= E, R,S) R4 Relay- Gas Heat Alarm (Code 04= A) R5 Relay- Gas Heat, Start Supply Fan Inverter (Code 4=,,3,5,6,7) R6 Relay- Isolation Damper- Open/Close R8 Relay- Isolation Damper Safety R30 Relay- Cool Valve w/ Face Bypass R45 Relay- UV Lights R46 Relay- Inverter, Supply Fan increase/decrease (Code 4= -3, 5-7) R48 Relay- Inverter, Return Fan increase/decrease (Code 4=,4,5,7-9) R6 Relay- Discharge Air Smoke Detector R63 Relay- Specials R64 Relay- Sump Pump R66 Relay- Return Air Smoke Detector (Code 6=, 3) R67 Relay- Supply Fan Enable R68 Relay- Return Fan Enable R69 Relay- Inverter Bypass VAV Interlock (Code 4= - 9) R70 Relay- Specials All R0 options are detailed here but for units with gas heat, the R0 is located in the Gas Heat Control Box (see section G). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 89

190 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Time Delays TD Time Delay- Compressor Lockout 300 Sec TD Time Delay- Compressor Lockout 300 Sec TD3 Time Delay- Hi Pressure 5 Sec TD4 Time Delay- Hi Pressure 5 Sec TD Time Delay- Low Ambient 65 Sec TD Time Delay- Low Ambient 65 Sec Transformers- Controls T Transformer- Control Input 5-4V T3 Transformer- Control Output 5-4V T4 Transformer- Exhaust Damper Actuator 5- VDC T9 Transformer- Refrigerant Circuit 4V Terminal Blocks TB Terminal Block- Internal TB, 7 Terminal Block TB3, 4 Terminal Block Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 0480 DAT Sensor- Discharge Air Temperature ENT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature SCC Units only (Code = *S). Not Shown on diagram. 3 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n Jumpers are p/n (TBA:5), (TBB:4), (TBC:0,TBD:5 & TBE:30). 4 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n ( pole), (3 pole), (4 pole), (5 pole). RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 90

191 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Gas Heat (Code 04= A) Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Fuses- T FA,B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Gas Heat (Code 04= A) Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) FC Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A MMP64 Motor Protector- Water Pump 4-5.9A Motor Protector- Water Pump.5-3.9A Motor Protector- Water Pump.6-.4A Spacer Link M65 Contactor- Sump Heater 5A Contactor- Sump Heater 8A Contactor- Sump Heater 9A FB65 Fuse Block- Sump Heater Fuse 5A Fuse 0A Fuse A Fuse 0A Fuse Guard T Transformers also use a Cover kit p/n & a Fuse Puller kit p/n (not used on Transformer p/ns , , ). Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. 3 Fuses used on Gas Heat Unit w/uv lights also use Fuse Block p/n & 3 Pullers p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

192 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Fuses F,F3, F5 Fuses Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA Transformer F3 Fuse- Blower Motor mbh furnace F3 Fuse- Blower Motor 000 mbh furnace F5 Fuse- UV Lights (Code 7 [Digit ]= - 8) Phase Voltage Monitor (Code 7= P,A,C,D,H,J,K) PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Ground Fault Protection (Code 7= G,B,C,D,K) GFR, Ground Fault Relay- SPDT GFS, Ground Fault Sensor Power Blocks PB, PB Power Block- Main (Code = P, Q) Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution Power Block- 40A Power Block- 760A Cover- 760A Block PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 00, 40, 80, 30 KW Electric Heat Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. PB is installed when Code = Q. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

193 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Power Blocks, continued PB0 Power Block- Supply Fan (Code 5= F) PB0 Power Block- Return Fan (Code 5= F) Receptacles REC Receptacle Power Supply Board PWR Power Supply Board 5VDC Disconnect Switch DS Disconnect Switch- Main Gas, Steam, HW, No Heat (Code 04= A, S, W, Y) Switch- 00A Handle Kit Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 600A,, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (code = A or B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n , Handle kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 93

194 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switch, continued DS Disconnect Switch- Main Electric Heat (Code 04= E) Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Switch- 600A,, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) OR 3 Disconnects (Code = D) then use Switch p/n , Handle kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 94

195 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switch, continued DS Disconnect Switch- SAF/RAF (Code = C, D) Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 95

196 Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker & Plugs Sch. Part Part Voltage Sym. Description Number Circuit Breakers- Supply & Return Fan CB0 CB0 Circuit Breaker- Supply Fan Circuit Breaker- Return Fan Motor HP= 5, 7.5, Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Plugs 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check installed part to verify. Not shown on diagram. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n ) & 6 pin cap kit (p/n ). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap kit p/n ). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 96

197 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Front Mtd. Contact 3E Aux. Contact Line Shield 3D 3A 3 MMP Front Mounted Contact 3E Link 3B 4 Spacer MMP 3 Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 3-0 HP Motors- All Voltages 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5, 0 HP Motors- 08/ 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ 60HP Motors- MMP 3 Lug 3G 3G 3 Lug MMP Trip Indicator Alarm 3F 3F Trip Ind. Interlock 3G Lug Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30, 40 HP Motors- 08/ 50 HP Motor- 60HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 50HP Motors- 60HP Motors- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 97

198 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 3 HP Motor- Code = H** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan Contactor- Return Fan MMP0 MMP- Return Fan MMP- Return Fan MMP- Return Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 98

199 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO OR NC Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 99

200 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 5 HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 00

201 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 40 HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Also requires 3 field supplied ring terminals. 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

202 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 60 HP Motor- Code OR 3= T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Lug (3 per kit) Also requires 3 field supplied ring terminals PER kit. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan MMP0 MMP- Supply Fan F Trip Indicator Alarm G Lug RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

203 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4 MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- & M- Link Detail 076C- 08/ 089C, 00C- 08/30/ MMP- & M- Link Detail 076C- 460/ 089C, 00C- Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor Contactor 50A Contactor 4 5A Contactor 4 80A Contactor 4 65A Compressor MMP s & Parts 3 MMP, Motor Protector 50-0A Motor Protector 90-50A Motor Protector A Motor Protector A Motor Protector 40-50A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 4 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. For 35 and 40HP compressors, in addition to the Contactor and MMP, the Auxiliary and Lug Kit MUST also be ordered. Refer to the Compressor listing in Section M to determine Compressor horsepower RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 03

204 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 0C, 30C- 08/ MMP- 4 & M- 4 Link Detail 0C, 30C- 460/ Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 50A Contactor 5A Contactor 3 65A Contactor 3 50A Compressor MMP s & Parts 3 MMP- 4 Motor Protector 90-50A Motor Protector 60-00A Motor Protector A Motor Protector A Motor Protector 30-40A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 04

205 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 40C Circuit #- 08/ 40C Circuit #, 50C- 08/30/ MMP- 4 & M- 4 Link Detail 40C Circuit #- 460/ 40C Circuit #, 50C- Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 50A Contactor 7 80A Contactor 7 65A M3, 4 Contactor 50A Contactor 7 80A Contactor 65A Compressor MMP s & Parts 3 MMP- Motor Protector 90-50A Motor Protector A Motor Protector A Motor Protector 40-50A MMP3, 4 Motor Protector 90-50A Motor Protector A Motor Protector 50-65A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage 7 7 combination. For unit size 40C, M, & MMP, are for the 30HP compressors; M3, 4 & MMP3, 4 are for the 35HP compressors. 3 Used on Circuit # only. 4 Used on Circuit # only. 5 Used on Circuit # only and does NOT require 3 field supplied ring terminals 6 Also requires 3 field supplied ring terminals. 7 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. For 35 and 40HP compressors, in addition to the Contactor and MMP, the Auxiliary and Lug Kit MUST also be ordered. Refer to the Compressor listing in Section M to determine Compressor horsepower. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 05

206 Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3B Link Circuit Breaker 5 4 Spacer Contactor Unit Size Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A M3, 3 Contactor- Condenser Fan 9A Fan MMP s & Parts 3 MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP3, 3 Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A B Link- MMP Spacer- Contactor Fan Circuit Breaker 5 CB Circuit Breaker- Condenser Fan The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 06

207 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Diagram COM MCB Deadfront Door (Closed view) The above diagrams show a typical two compressor (size C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 07

208 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Control Box Component Label Diagram Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 08

209 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller w/ HMI Display Terminal Block, MCB- Pole Terminal Block, MCB- 3 Pole Terminal Block, MCB- 5 Pole Terminal Block, MCB- 6 Pole Terminal Block, MCB- 7 Pole Terminal Block, MCB- 8 Pole Expansion Module EXPA- D Expansion Module Board to Board Connector, 4 Pin /board Terminal Block, Board to Wire Connector EXP- Pole /board Terminal Block, Board to Wire Connector EXP- 3 Pole /board Terminal Block, Board to Wire Connector EXP- 7 Pole /board Terminal Block, Board to Wire Connector EXP- 8 Pole /board Communication Card COM Bacnet- MSTP (Code = BE, BF, BW) Bacnet- IP (Code = EE, EF, EW) LonWorks- Discharge (Code = LE, LW) LonWorks- Constant Volume (Code = LF) Resistors 4 RES Resistor- Refrigeration Circuit # 500 OHM RES Resistor- Refrigeration Circuit # 000 OHM RES3 Resistor- Freezestat (FS) 000 OHM RES4 Resistor- OAE 500 OHM RES6-8 Resistor- SPS, SPS, SPS3 500 OHM /switch Switches- Control HS Switch- Electric Heat Shutdown (Code 04= E) S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A Gas Heat Units with UV Lights 4PST/30A Electric, Steam, HW, No Heat with no UV Lights SPST/0A Electric, Steam, HW, No Heat with UV Lights DPST/5A S4 Switch- Inverter Bypass On/Off DPST/5A S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V T3 Transformer- Control 0-4V Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 5, Pressure Transducer- Duct Sensor (0/ thru 5/3) Pressure Transducer Kit- Space Sensor (9/ & Earlier) 5, Pressure Transducer- Space Sensor (0/ thru 5/3) The Main Controller must be programmed in order to function correctly. When ordering a replacement MCB, provide the unit model and serial number so the unit specific software code can be loaded before shipment. Quantity varies depending upon unit options selected. 3 This part does NOT come with the Expansion Module; order separately if needed. 4 Not Shown on diagram. 5 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 6 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail, Resistor, Sampling Tube, and Installation Instructions. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 09

210 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- Condenser Fan R3 Relay- Condenser Fan R4 Relay- Condenser Fan R0 Relay- Heat R5 Relay- Gas Heat, Start Supply Fan Inverter 3 (Code 4=,,3,5,6,7) R6 Relay- Isolation Damper- Open/Close R8 Relay- Isolation Damper Safety R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, Duct & Space Sensor OR Space Sensor Code 3= 3, DHL Sensor Code 3= Units with Return Fan Inverter Code 4= 4, 8, 9 Space Sensor Code 3= Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y R64 Relay- Sump Pump Time Delays TD3 Time Delay- Hi Pressure 3 5 Sec TD4 Time Delay- Hi Pressure 3 5 Sec TD0 Time Delay- Return Air Fan Terminal Block TB Terminal Block Phase Voltage Monitor 3 PVM Phase Voltage Monitor 08/30/ 000 Phase Voltage Monitor 000 Sensors/Switches ZNT Sensor- Zone Temperature w/ Tenant Override Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., DAT Sensor- Discharge Air Temperature EFT Sensor- Entering Air Temperature OAT Sensor- Outside Air Temperature RAT Sensor- Return Air Temperature EAT Sensor- Exhaust Air Temperature LAT Sensor- Leaving Air Temperature Remote Display KEYPAD Remote Interface Display Varies depending on unit options. Part number is for one individual section. Ground block is p/n SCC Units only- Code = BF, LF, EF, SF. 3 Not Shown on diagram. 4 Used with Controller (MCB) w/o Display (HMI) p/n: RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

211 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E, S, W, Y) Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Gas Heat Code 04= A Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Fuses- T FA,B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Gas Heat (Code 04= A) Units without UV Lights Units without UV Lights Units without UV Lights Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) Units with UV Lights (Code 7 [Digit ]= - 8) FC Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Fuse- T Transformer, Secondary Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A MMP64 Motor Protector- Water Pump 4-5.9A Motor Protector- Water Pump.5-3.9A Motor Protector- Water Pump.6-.4A Spacer Link M65 Contactor- Sump Heater 5A Contactor- Sump Heater 8A Contactor- Sump Heater 9A FB65 Fuse Block- Sump Heater Fuse 5A Fuse 0A Fuse A Fuse 0A Fuse Guard T Transformers also use Cover kit p/n & Fuse Puller kit p/n (not used on Transformer p/ns , , ). Fuse depends on heat type and presence of UV lights = Gas Heat Unit w/uv lights; = Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; = Non- Gas Heat Units with no UV lights. 3 Fuses used on Gas Heat Unit w/uv lights also use Fuse Block p/n & 3 Pullers p/n RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

212 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Terminal Blocks TB, 7 Terminal Block TB3, 4 Terminal Block Fuses F, F3, F5 Fuses 4 Fuse Block /fuse /fuse /fuse /fuse Fuse Cover /fuse /fuse /fuse /fuse F Fuse- 000+VA Transformer F3 Fuse- Blower Motor mbh furnace F3 Fuse- Blower Motor mbh furnace F5 Fuse- UV Lights 4 (Code 7 [Digit ]= - 8) F- 3 Fuse Blocks- Condenser Fan /fan /fan /fan /fan Fuse- Condenser Fan /fan /fan /fan /fan Fuse Cover/Puller- Condenser Fan /fuse /fuse /fuse /fuse Power Blocks PB, PB Power Block- Main 4 (Code = P, Q) Power Block, Non- Electric Heat Units- 75A Power Block, Electric Heat Units- 75A Lug- 75A Block Power Block, Non- Electric Heat Units- 55A Lug- 55A Block Power Block, Non- Electric Heat Units- 380A Power Block, Electric Heat- 380A Lug- 380A Block Power Block, Non- Electric Heat Units- 60A Cover- 60A Block Lug- 60A Block Power Block, Non- Electric Heat Units- 760A Power Block, Electric Heat Units, 08/- 760A Power Block, Electric Heat Units, 460/- 760A Cover- 760A Block Lug- 760A Block Power Block, Non- Electric Heat Units- 840A Cover- 840A Block Lug- 840A Block PB Power Block- Power Distribution 3 Power Block- 40A Power Block- 760A Cover- 760A Block Varies depending on unit options. Part number is for one individual section. Ground Block is p/n Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n ( pole), (3 pole), (4 pole), (5 pole). 3 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. PB is installed when Code = Q. 4 Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

213 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Power Blocks, continued 4 PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat , 80, 00, 0 KW Electric Heat , 80, 00, 0 KW Electric Heat , 00, 40, 80, 30 KW Electric Heat PB0 Power Block- Supply Fan (Code 5= F) PB0 Power Block- Return Fan (Code 5= F) Receptacles 4 REC Receptacle Disconnect Switches 4 DS Disconnect Switch- Main Gas, Steam, HW, No Heat (Code 04= A, S, W, Y) Switch- 00A Handle Kit Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 50A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 400A Handle Kit (with operating mechanism) Shaft Ground Lug Switch- 600A,, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n , Handle kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. 4 Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

214 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switches, continued DS Disconnect Switch- Main Electric Heat (Code 04= E) units Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Switch- 600A,, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 800A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Switch- 000A, Handle Operating Mechanism Shaft Shaft- Mod Ground Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A Switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n , Handle kit p/n , Shaft p/n , and Ground Lug p/n Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

215 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switches, continued DS Disconnect Switch- SAF/RAF (Code = C, D) Switch- 00A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 50A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Switch- 400A Handle Kit Shaft Ground Lug Load Lug Cover- Load Lug Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

216 Sch. Part Part Voltage Sym. Description Number Circuit Breakers- Supply & Return Fan CB0 CB0 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Circuit Breaker- Supply Fan Circuit Breaker- Return Fan Motor HP= 5, 7.5, Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= 0, Motor HP= Motor HP= Motor HP= 5, Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Motor HP= Plugs 4 Pin Plug varies varies varies varies 3 6 Pin Plug varies varies varies varies 4 Pin Plug varies varies varies varies 5 3 Pin Cap Kit varies varies varies varies 6 6 Pin Cap Kit varies varies varies varies 7 9 Pin Cap Kit varies varies varies varies 8 5 Pin Cap Kit varies varies varies varies All possible Plugs used are listed. Check installed part to verify. Not shown on diagram. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n ) & 6 Pin Cap Kit (p/n ). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n & Cap Kit p/n ). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

217 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Front Mtd. Contact 3E Aux. Contact Line Shield 3D 3A 3 MMP Front Mounted Contact 3E Link 3B 4 Spacer MMP 3 Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 3-0 HP Motors- All Voltages 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5, 0 HP Motors- 08/ 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ 60HP Motors- MMP 3 Lug 3G 3G 3 Lug MMP Trip Indicator Alarm 3F 3F Trip Ind. Interlock 3G Lug Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30, 40 HP Motors- 08/ 50 HP Motor- 60HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 50HP Motors- 60HP Motors- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

218 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 3 HP Motor- Code = H** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan Contactor- Return Fan MMP0 MMP- Return Fan MMP- Return Fan MMP- Return Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

219 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan MMP- Supply (MMP0) OR Return (MMP0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO OR NC Spacer HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO OR NC Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 9

220 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 5 HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan B Link E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Spacer RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 0

221 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 40 HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Also requires 3 field supplied ring terminals. 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

222 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 60 HP Motor- Code OR 3= T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan Contactor- Supply (M0) OR Return (M0) Fan MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan MMP- Supply (M0) OR Return (M0) Fan E Aux. Contact- NO or NC F Trip Indicator Alarm G Lug (3 per kit) Lug (3 per kit) Also requires 3 field supplied ring terminals PER kit. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan MMP0 MMP- Supply Fan F Trip Indicator Alarm G Lug RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page

223 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4 MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- & M- Link Detail 076C- 08/ 089C, 00C- 08/30/ MMP- & M- Link Detail 076C- 460/ 089C, 00C- Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor Contactor 50A Contactor 5A Contactor 80A Contactor 65A Compressor MMP s & Parts 3 MMP, Manual Motor Protector 50-0A Manual Motor Protector 90-50A Manual Motor Protector 60-00A Manual Motor Protector 50-65A Manual Motor Protector 40-50A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 3

224 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 0C, 30C- 08/ MMP- 4 & M- 4 Link Detail 0C, 30C- 460/ Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 50A Contactor 5A Contactor 65A Contactor 50A Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector 90-50A Manual Motor Protector 60-00A Manual Motor Protector 50-65A Manual Motor Protector 40-50A Manual Motor Protector 30-40A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 4

225 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 40C Circuit #- 08/ 40C Circuit #, 50C- 08/30/ MMP- 4 & M- 4 Link Detail 40C Circuit #- 460/ 40C Circuit #, 50C- Unit Size Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 50A Contactor 80A Contactor 65A M3, 4 Contactor 50A Contactor 80A Contactor 65A Compressor MMP s & Parts 3 MMP- Manual Motor Protector 90-50A Manual Motor Protector 60-00A Manual Motor Protector 50-65A Manual Motor Protector 40-50A MMP3, 4 Manual Motor Protector 90-50A Manual Motor Protector 60-00A Manual Motor Protector 50-65A E Aux. Contact- NO or NC Front Mounted Contact- NO G Lug Kit (3 lugs per kit) The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. For unit size 40C, M, & MMP, are for the 30HP compressors; M3, 4 & MMP3, 4 are for the 35HP compressors. 3 Used on Circuit # only. 4 Used on Circuit # only. 5 Used on Circuit # only and does NOT require 3 field supplied ring terminals 6 Also requires 3 field supplied ring terminals RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 5

226 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3B Link Circuit Breaker 5 4 Spacer Contactor Unit Size Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A M3, 3 Contactor- Condenser Fan 9A Fan MMP s & Parts 3 MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP, Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A MMP3, 3 Manual Motor Protector A Manual Motor Protector.5-4.0A Manual Motor Protector.6-.5A B Link- MMP Spacer- Contactor Fan Circuit Breaker 5 CB Circuit Breaker- Condenser Fan The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 6

227 Section N- Controls MicroTech III: Code = *E, *F, *W- 6/3 & Later Main Control Box Diagram COM MCB Deadfront Door (Closed view) The above diagrams show a typical two compressor (size C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 7

228 Section N- Controls MicroTech III: Code = *E, *F, *W- 6/3 & Later Control Box Component Label Diagram GOI Number: H R0 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description BB FB Fuse Holder, 3 Pole, 00A, 600V, Cl BB FB Fuse 00A 600V Class J Fast Acti BB FB Cover, Fuse Holder, 3 Pole, 00A, C BB FB Fuse 50A 600V Class J Fast Actin BB M30I Contactor IEC Reversing 40A 0VAC BB M30I Contactor Auxiliary Contact NO NC BB M30I MMP to Contactor Link Module Size S BB M40I Contactor IEC Reversing 5A 0VAC BB M40I MMP to Contactor Link Module Screw BB M40I MMP to Contactor Spacer Size S0 BB M40I SCREW, PANHEAD B-type, #8 X " BB MMP MMP Class 0 Size S 8 to 40A BB MMP MMP Auxiliary Contact Sizes S and BB MMP MMP Class 0 Size S0 4 to 0A Scre BB MMP MMP Auxiliary Contact Sizes S00 and BB MMP MMP Type E Phase Barrier Sizes S00 GB AS Ctrl-press air switch gas burner GB AS Conduit fitting nipple GB FLC Control Temp Fan Limit Gas Heat GB FSG Ctrl-temp flame safegrd base GB FSG Ctrl-temp Flame Safegrd Control GB FSG Ctrl-temp flame safegrd amplifier GB FSG Ctrl-temp flame safegrd timer 90 GB IT Transformer Ignition GB LS Limit switch GB LS Limit switch GB R0A DPDT Relay 5A 0VAC GB R0A Mounting Adapter P Relay to Dinra GB S Switch Toggle 4PST 5V MB BNMS Communication Card, BACnet-MSTP, MT MB DS Circuit Breaker Molded Case Switch MB DS lug kit, 3 pcs with power control t MB DS Connector -4 quick connect tab MB DS lug kit, 3 pcs, T3 Frame, 5A MB DS SCREW, PANHEAD AB-type, #8-8 X 3" MB DS Circuit Breaker Operating Mechanism MB DS 9340 HANDLE, PISTOL, ABB DISCONNECT, RED MB DS Fuse holder, Circuit Protector, P MB DS Fuse 0A Rejection Type MB EXP-B Extension I-O 5 Points MB EXP-B Connector for extension I-O - Direc MB EXP-C Extension I-O 5 Points MB EXP-C Connector for extension I-O - Direc MB F Fuse A Midget Non-Rejection Typ MB FS Fuse, 5A 600V Class CC Type T Fast MB F Fuse A Midget Non-Rejection Typ MB FA Fuse 0A Rejection Type MB FB Fuse 0A Rejection Type MB FC Fuse 0A Midget Non-Rejection Ty MB F Fuse 5A Midget Non-Rejection Ty MB F Fuse A Midget Non-Rejection Typ MB F Fuse A Midget Non-Rejection Typ MB F Fuse 5A Midget Non-Rejection Ty MB F6C Fuse 0A Midget Non-Rejection Ty MB FB Fuse A Rejection Type MB GRD Terminal x spring Green row MB KEYPAD REMOTE HMI, PANEL MOUNT MB M Contactor IEC 80A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 7A 0VAC Coil Spring MB M Contactor Auxiliary Contact NO NC MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor Auxiliary Contact NO NC MB M Contactor IEC 80A 0VAC Coil Screw MB M Contactor Auxiliary Contact NO NC MB M MMP to Contactor Link Module Size S MB M Contactor IEC 7A 0VAC Coil Spring MB M Contactor Auxiliary Contact NO NC MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor Auxiliary Contact NO NC MB M Contactor IEC 7A 0VAC Coil Spring MB M MMP to Contactor Link Module Screw MB M Contactor IEC 7A 0VAC Coil Spring MB MCB Base Controller with IP MB MMP MMP Class 0 Size S3 57 to 75A MB MMP MMP Auxiliary Contact Sizes S and MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Type E Phase Barrier Sizes S00 MB MMP MMP Class 0 Size S3 57 to 75A MB MMP MMP Auxiliary Contact Sizes S and MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Auxiliary Contact Sizes S00 and MB MMP MMP Type E Phase Barrier Sizes S00 MB MMP MMP Class 0 Size S00. to 3.A S MB MMP MMP Type E Phase Barrier Sizes S00 MB OAER DPDT Relay 0A 4VAC MB OAER Relay Socket DPDT MB OL Overload Relay Class 0 Size S00. MB OL Overload Relay Class 0 Size S00. MB PB Distribution Power Terminal Brd 4 MB PS Switch Toggle SPST-0A 5va MB PS Switch Toggle SPST-0A 5va MB PVM 000 3PH Monitor VAC MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R PDT Relay 0A 0VAC MB R Relay Socket 3PDT MB R DPDT Relay 0A 0VAC MB R Relay Socket DPDT MB R DPDT Relay 0A 4VDC MB R Relay Socket DPDT MB RES RESISTOR 500 Ohm -8 Watt % Pr MB S Switch Toggle DPST 5V MB S Switch Toggle SPST-0A 5va MB S Switch Toggle 3position ON-OFF-O MB S Switch Toggle position ON-ON S MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB SPS SENSOR, AIR PRESSURE/VELOCITY, DIN MB T MICRON Transformer, CPT, W/ FB, 00 MB T Cover, Terminals, Micron 6-terminal MB T Cover, Fuseholder, Micron Type Tr MB T Washer, /4" Flat MB T Washer, Split Lock MB T Transformers 75va 0V-4Vac MB T Transformers 75va 0V-4Vac MB T MICRON Transformer, CPT, WO/ FB, 0 MB T Cover, Terminals, Micron 6-terminal MB T Washer, /4" Flat Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE C Rev. K 07/6 RPL / Page 8

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018 Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(

More information

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,

More information

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018 Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016 Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998 Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier eplacement Parts List No. 000000 evision F 09/06 McQuay oofpak Condensing Unit Medium Cabinet, Standalone CS 050-05 Tons Vintage C Code = A, A Valid f units built 06/00 & Earlier To find your Daikin Applied

More information

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016 Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com

More information

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems Installation and Maintenance IM-709 Group: Applied Systems Part Number: IM709 Date: January 2002 Self-contained Air Conditioning System Type SWT C Vintage Sizes 18 thru 40 MEA 368-93-E 2002 McQuay International

More information

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

Installation and Maintenance Manual IM 988-1

Installation and Maintenance Manual IM 988-1 Installation and Maintenance Manual IM 988-1 Self-Contained Air Conditioning Systems Model SWT C Vintage Sizes 18 through 40 MicroTech III Unit Controller R-407C Refrigerant Group: Applied Air Systems

More information

RoofPak Singlezone Roof Mounted Heating and Cooling Units

RoofPak Singlezone Roof Mounted Heating and Cooling Units Installation and Maintenance Manual IM 926 RoofPak Singlezone Roof Mounted Heating and Cooling Units Group: Applied Systems Part Number: IM 926 Date: October 2008 RPS/RDT/RFS/RCS 015C - 105C MicroTech

More information

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017 Replacement Parts List No. 7000800 Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage B To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988 Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993 Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,

More information

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC) Point Map December 1, 2004 Systems Integration McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC) Table 1. Microtech II Self-contained Unit Controller

More information

RoofPak Singlezone Roof Mounted Heating and Cooling Units

RoofPak Singlezone Roof Mounted Heating and Cooling Units Installation and Maintenance Manual IM 78- RoofPak Singlezone Roof Mounted Heating and Cooling Units RPS/RDT/RFS/RCS 05 5C Group: Applied Systems Part Number: IM 78- Date: October 00 00 McQuay International

More information

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design

More information

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

RoofPak Applied Rooftop Systems Air Handler

RoofPak Applied Rooftop Systems Air Handler Installation & Maintenance Data IM 178-6 Group: Applied Systems Part Number: 347673Y-01 Date: January 1997 RoofPak Applied Rooftop Systems Air Handler RDS 800C & 802C L I S T E D C L I S T E D 1997 McQuay

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015 Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Installation and Maintenance Manual IM 893-6

Installation and Maintenance Manual IM 893-6 Installation and Maintenance Manual IM 893-6 Group: Applied Air Systems Part Number: IM 893 Date: October 2014 RoofPak Singlezone Heating and Cooling Units RPS/RDT/RFS/RCS 015D 140D with MicroTech III

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017 Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

AIR HANDLER DESIGN WORK SHEET

AIR HANDLER DESIGN WORK SHEET AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD]

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

RoofPak Singlezone Roof Mounted Heating and Cooling Units

RoofPak Singlezone Roof Mounted Heating and Cooling Units Installation and Maintenance Manual IM 893-2 RoofPak Singlezone Roof Mounted Heating and Cooling Units Group: Applied Systems Part Number: IM 893 Date: September 2010 RPS/RDT/RFS/RCS 015D 140D R-410A Refrigerant

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012 Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

RoofPak Singlezone Roof Mounted Heating and Cooling Units

RoofPak Singlezone Roof Mounted Heating and Cooling Units Installation and Maintenance Manual IM 893-1 RoofPak Singlezone Roof Mounted Heating and Cooling Units Group: Applied Systems Part Number: IM 893 Date: November 2009 RPS/RDT/RFS/RCS 015D 140D R-410A Refrigerant

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Installation Manual IM

Installation Manual IM Installation Manual IM 1032-2 Group: Applied Air Systems Part Number: IM 1032 Date: December 2013 Self-Contained Air Conditioning Systems Type SWP Vintage H Refrigerant R-410A Capacity 20 through 130 tons

More information

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017 Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994 Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787

More information

MEA. Self-Contained Air Conditioning System. Installation and Maintenance. Type SWP Vintage Sizes 18 through 95, 105. Group: Applied Systems

MEA. Self-Contained Air Conditioning System. Installation and Maintenance. Type SWP Vintage Sizes 18 through 95, 105. Group: Applied Systems Installation and Maintenance IM 0- Group: Applied Systems Part Number: IM 0 Date: September 005 Self-Contained Air Conditioning System Type SWP Vintage Sizes through 95, 05 MEA 6-9-E 005 McQuay International

More information

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018 Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018 Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993 Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017 Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4) Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A Replacement Parts List No. 700014100 Revision P 05/2017 Daikin McQuay Pathfinder Air Cooled Chiller Screw Compressor Two Circuit AWS 150-405 Vintage A For units built after 8/1/11, contact Daikin Applied

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Catalog RoofPak Applied Rooftop Systems with Energy Recovery Wheels

Catalog RoofPak Applied Rooftop Systems with Energy Recovery Wheels RoofPak Applied Rooftop Systems with Energy Recovery Wheels Catalog 220-1 Packaged Heating and Cooling Units Type RFS/RPS 15 to Tons Type RDT 45 to Tons Rooftop Air Handlers Type RAH/RDS 4,000 to 30,000

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62) Replacement Parts List No. 700026200 Revision E 05/2017 Daikin McQuay Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit AWS 400-550 Vintage B Unit Revision 0B (Code 62) To find your Daikin Applied

More information

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RN SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Self-Contained Air Conditioning System

Self-Contained Air Conditioning System Installation and Maintenance Manual IM 1032 Self-Contained Air Conditioning System Group: Applied Air Systems Part Number: IM 1032 Date: March 2011 Type SWP H Vintage 2011 McQuay International Introduction.................................

More information

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RN SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left

More information

SECTION ROOFTOP REPLACEMENT AIR UNITS

SECTION ROOFTOP REPLACEMENT AIR UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons Product Data 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RQ SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018 Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RN SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017 Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information