HV to HE Conversion Kit Installation

Size: px
Start display at page:

Download "HV to HE Conversion Kit Installation"

Transcription

1 Small Duct Heating, ooling and Indoor Air Quality Systems TM HV to HE onversion Kit Installation Manufactured By Module HK - HV to HE onversion Kit Installation

2 Motor and Blower Preparation Module HK HV to HE onversion (2/10) This document will show you step by step instructions on converting a HV fancoil with a multi-speed motor to the HE style with a variable speed motor. The HE ontrol Board is programmed with multiple speeds and air flows controlled by the thermostat and dip set ranges for each style of blower. The ontrol Board converts the supplied single phase power of 100v-240v and converts the power to 3 phase motor and sends 3 phase power to the motor. The Heavy Duty 3 Phase Motor provides years of reliable service, as the heavy duty construction and power limiting function of the EP controller minimizes motor stress and wear. The new inverter drive technology offered by the EP Motor and ontroller reduces power consumption by up to 70%, with an average overall yearly reduction of 50% over standard PS motors. oise related to excess power input is eliminated. Part Part umber HE-50 onversion Kit HE-70 onversion Kit HE-100 onversion Kit HV to HE onversion Kit Each kit will include the following: EP 3/4 hp Motor c/w Motor Mounting Bracket Electrical Box c/w ontrol Board, ircuit Board and Transformer HE enter Plate (50, 70 or 100 Size) HE Blower (50, 70, 100 Size) (1 1/2") (1 1/2 ) (1 1/4") ot Used Mounting Bolt Assembly 1 1/4" HE-50/52 HE-70 HE-100 HE-50 1/2 HE-52 7/8" HE-70 2" Middle OTE: Bracket bolt and wire to line up (center) HE-70&100 HE-50: Just below the silver rim, line up bolt and wire as shown HE-70: 2 from flat part of the silver rim HE-100: Middle of the motor housing enter blower wheel in the blower cabinet and tighten the set screw on blower to motor, be sure to use thread lock glue on set screw Wire as shown here (bottom/side) OTE: This manual applies to the HV single sided access units manufactured from with the blower mounted on the center plate. For older units with the blower mounted on the fan coil cabinet, simply remove the controls, center plate blower and blower/motor, and install conversion kit as per shown in this manual. Module HK - HV to HE onversion Kit Installation (2/10) Energy Saving Products td.

3 Module HK HV to HE onversion (3/10) 1. Shut off electric power to the unit. HV Fan oil Preparation 2. Make note of the pump timer setting. abel all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. 3. Disconnect electrical power from the circuit board. 4. Disconnect motor connection and all thermostat wires, condensing unit, freeze stat, circulator, zone valve etc. It is not necessary to remove wires completely from the fan coil, it may be necessary to bring the wires into the new HE Electrical box before sliding the electrical box into place. 5. Remove existing HV ircuit Board Electrical box. 6. Remove mounted motor and blower. 7. arefully remove center plate trying not to damage the insulation lining in the unit. Depending on the clearance on the outside of the fan coil, it may be easier to cut the screws from inside, depending on the clearances around the unit. Remove Screws Module HK - HV to HE onversion Kit Installation (3/10) Energy Saving Products td.

4 Module HK HV to HE onversion (4/10) HE omponent Installation 8. Bend down the HV ontrol Box mounting metal tabs flat if located in fan coil. 9.Install new center plate, careful not to damage the insulation lining in the unit. 10. Replace screws. Depending on the clearance on the outside of the fan coil, it may be easier to replace the screws from the inside to out. 11. Install EP mounted motor and blower. 12. Install EP Electrical box and connect motor. (See next page) 12 Replace Screws Module HK - HV to HE onversion Kit Installation (4/10) Energy Saving Products td.

5 HE Electrical Box Installation Module HK HV to HE onversion (5/10) 13. Slide ontrol Box into fan coil allow the metal flange to clip onto the fan coil cabinet while the other side simply rests on the Fan oil cabinet. 14. Bring motor wires into control box, insert wires into plastic clip and insert plastic clip to protect the motor wires. Reconnect motor to the control board onnect motor ground to the electric board box Reconnect all thermostat wires, condensing unit, freeze stat, circulator, zone valve etc. hange pump timer setting and dip switch settings for the new board assembly. Reconnect electrical power to the board. 17. Replace door covers on fan coil and replace wiring sticker on the door. Write down on provided sticker the Model and Serial umber of the fan coil and stick to the bottom of old control box. Return to supplier. Module HK - HV to HE onversion Kit Installation (5/10) Energy Saving Products td.

6 Module HK HV to HE onversion (6/10) Wiring 1 Stage stage ooling cooling 1 Stage 1 stage Heating heating 24v 1 stage Stage ooling cooling 2 Stage 2 stage Heating heating Heatpump heatpump DESER DESER Y 24v Y O/B R SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (W1 OR W2) R Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA DRY TATS REAY WIRIG 24 VA REAY WIRIG 115 VA REAY WIRIG SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (1 STAGE - W2 Y) Z1 H1 X2 AUXIIARY REAY (HEATIG) AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y Z1 H1 X2 AUXIIARY REAY (HEATIG) AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y DRY TAT TO BOIER EXTERA SPDT REAY 24 VA OI DRY TATS AD 115 VA REAY WIRIG T T X2 H1 Z1 115v IRUATOR W1 W2 G R Y2 Y1 D O/B W1 W2 G R Y2 Y1 D O/B SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (W1 OR W2) W G R Y THERMOSTAT E W2 G R Y O/B THERMOSTAT Z1 H1 X2 DRY TAT TO BOIER T T EXTERA SPDT REAY 24 VA OI 115 V TO IRUATOR 1 Stage stage ooling cooling 2 Stage 2 stage Heating heating 24v Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO DESER Y AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA 2 stage 2 Stage cooling ooling 3 Stage stage Heating heating Heatpump DESER heatpump 24v Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO Y2 Y1 O/B R Y2 WIRE TO ATI-IE TRO TO ITERRUPT THE DESERS Y2 SIGA G W1 W2 R Y2 Y1 D O/B DRY TATS AD 115 VA REAY WIRIG Z1 H1 X2 AUXIIARY REAY (HEATIG) W1 W2 G R Y2 Y1 D O/B E W1 W2 G R Y THERMOSTAT AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y Z1 H1 X2 AUXIIARY REAY (HEATIG) W1 W2 G R Y2 Y1 D O/B E W3 G R Y2 Y1 O/B THERMOSTAT AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y FOR SIGE STAGE OPERATI USE W2 & Y2 TERMIAS R - 24VA OUTPUT W1 - FIRST STAGE HEAT W2 - SED STAGE HEAT (OR SIGE STAGE) Y1 - FIRST STAGE OOIG Y2 - SED STAGE OOIG (OR SIGE STAGE) - 24 VA OMM G - THERMOSTAT FA SWITH D - DEHUMIDIFIATI O/B - HEATPUMP REVERSIG VAVE - EUTRA - IE VOTAGE - AUXIIARY ORMAY OPE - AUXIIARY ORMAY OSED - AUXIIARY OMM - FREEZE STAT X2 - FREEZE STAT H1 - DESIG UIT 24V OUTPUT (Y) - 24 VA OMM Z1 - HEATIG MODE 24V OUTPUT - 24 VA OMM Energy Saving Products Street, Edmonton, AB T5-08 ESP Module HK - HV to HE onversion Kit Installation (6/10) Energy Saving Products td.

7 HE Fan oil - 24V Wiring ontrols Module HK HV to HE onversion (7/10) W1 W2 G R Y2 Y1 W1 input to 1st (low stage) heat calls. Active when R is applied. Activates 1st stage heat fan and Auxiliary Relay. (W1 operates at 60% of W2 Fan Speed) W2 input to 2nd (high/primary stage) heat calls. Active when R is applied. Activates 2nd stage heat fan, Auxiliary Relay and 24V to Z1 (W2 operates at 200 FM per ton (94 /s), refer to dip setting) 24V supply common G input for thermostat fan switch. Active when R is applied (G operates at 50% of Y2 Fan Speed) 24V supply Y2 input to 2nd (high/primary stage) cooling or heat pump call. Active when R is applied. Activates 2 stage cooling fan speed, activates with 24V for freeze stat and condenser connections (Y2 operates at 250 FM per ton (118 /s), refer to dip setting) Y1 input to 1st (low stage) cooling or heat pump calls. Active when R is applied. Activates 1 stage cooling fan speed. (Y1 operates at 60% of Y2 Fan Speed) D 24V input required from dehumidistat switch activates blower system to 200 FM per ton (94 /s) from dip setting. Y2 must be activated from thermostat. (D operates at 200 FM per ton (94 /s), refer to dip setting) O/B Blind contact for condenser heat pump from thermostat X2 H1 Z1 24V Signal with calls from Y2, powers Freeze Stat Freeze Stat connection return signal 24V Signal to Y on ondenser ommon for ondensing Unit 24V supply on W2 call ommon *ote: to X2 recommended to be wired to Freeze Stat (Anti-Ice ontrol) If Freeze Stat is not used, a jumper between to X2 must be installed to complete the H1-24V Signal to Y on ondenser (i.e. hilled Water Systems) Module HK - HV to HE onversion Kit Installation (7/10) -7- v Energy Saving Products td.

8 Module HK HV to HE onversion (8/10) EP ircuit Board Pin Settings and Air Flow Data (Standard) Model: HE-50 Model: HE-50 # Outlets Model: HE-50 # Outlets ooling: 1.5 Ton Mode Airflow in FM ooling: 2.0 Ton Mode Airflow in FM Heating: 32 MBH Hi ooling (Y2) Heating: 40 MBH Hi ooling (Y2) ESH: 5-10 kw o ooling (Y1) ESH: 5-15 kw o ooling (Y1) Dehumid (D) Dehumid (D) Hi Heating (W2) Hi Heating (W2) o Heating (W1) o Heating (W1) Pin Setting onstant (G) Pin Setting onstant (G) Model: HE-70 Model: HE-70 # Outlets Model: HE-70 # Outlets ooling: 2.5 Ton Mode Airflow in FM ooling: 3.0 Ton Mode Airflow in FM Heating: 51 MBH Hi ooling (Y2) Heating: 58 MBH Hi ooling (Y2) ESH: 5-18 kw o ooling (Y1) ESH: 5-18 kw o ooling (Y1) Dehumid (D) Dehumid (D) Hi Heating (W2) Hi Heating (W2) o Heating (W1) o Heating (W1) Pin Setting onstant (G) Pin Setting onstant (G) Model: HE-100 Model: HE-100 # Outlets Model: HE-100 # Outlets ooling: 3.5 Ton Mode Airflow in FM ooling: 4 Ton Mode Airflow in FM Heating: 72 MBH Hi ooling (Y2) Heating: 80 MBH Hi ooling (Y2) ESH: 5-18 kw o ooling (Y1) ESH: 5-20 kw o ooling (Y1) Dehumid (D) Dehumid (D) Hi Heating (W2) Hi Heating (W2) o Heating (W1) o Heating (W1) Pin Setting onstant (G) Pin Setting onstant (G) Model: HE-100 # Outlets ooling: 5.0 Ton Mode Airflow in FM Heating: 94 MBH Hi ooling (Y2) ESH: 5-23 kw o ooling (Y1) Dehumid (D) Hi Heating (W2) o Heating (W1) Pin Setting onstant (G) Minimum of eight 2 (51mm) outlets per ton of cooling (HE Duct = Minimum four outlets per ton) ESH = Electrical Strip Heaters, minimum of 7 outlets per 5kW is required Black indicates dip switch position: OFF Module HK - HV to HE onversion Kit Installation (8/10) Energy Saving Products td.

9 The extended pin settings show how to increase or decrease the required FM on the Hi-Velocity-HE fan coil for fine tuning. The chart illustrates the FM difference achieved changing pins 6, 7, and 8. Only these three pins are modified to increase or decrease the FM based upon the selected tonnage of pins 1 through EP Dip Ranges & Extended Air Flow Adjustments EP Dip Ranges Module HK HV to HE onversion (9/10) FM output tons / 5.3 kw 2 tons / 7.0 kw 2.5 tons / 8.8 kw 3 tons / 10.6 kw 3.5 tons / 12.3 kw 4 tons / 14.1 kw 5 tons / 17.6 kw dip setting Extended Air Flow Adjustments The extended pin setting applies to all HE fancoils and can be used to lower or raise FM output. Only PI s 6,7,8 are changed in order to modify the FM output Pin Setting Result 1. Decrease Ideal (default) Black indicates DIP switch position Module HK - HV to HE onversion Kit Installation (9/10) -9- Increase Energy Saving Products td.

10 Energy Saving Products td., established in 1983, manufactures the Hi-Velocity Systems TM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on ustomer Service and provides design services and contractor support. For all of your Heating, ooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you! Small Duct Heating, ooling and IAQ Systems Build Smart, Breathe Easy Hi-Velocity HE Fan oils, Green Technology HARDI Phone: Fax: Toll Free: velocity.com

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

ESP. Variable Speed Heat Pump. Installation and Operation.   3 Ton ESP Ton ESP-60 Heating, ooling and Indoor Air Quality Systems ESP Variable Speed Heat Pump 3 Ton ESP-36 5 Ton ESP-60 Installation and Operation www.hi-velocity.com Module-VAR-Variable-Speed-Heat-Pump-060118 Installation

More information

LV Installation Manual

LV Installation Manual LV Installation Manual Includes: LV-50 LV-70 LV-120 LV-140 Manufactured By Energy Saving Products Ltd. ESP 202.02b INSTALLATION, OPERATING, AND MAINTENANCE MANUAL LO-V UNIT INSTALLATION INSTRUCTIONS Lo-V

More information

LV Installation Manual

LV Installation Manual LV Installation Manual Includes: LV-50 LV-70 LV-120 LV-140 Manufactured By Energy Saving Products Ltd. Module-LV-Series-Installation-Manual-111915 INSTALLATION, OPERATING, AND MAINTENANCE MANUAL LO-V UNIT

More information

R Series Cooling Manual

R Series Cooling Manual Mini Duct Heating and Air Conditioning Indoor Air Quality Systems R Series Cooling Manual Includes: RPM-E-50 Cooling Module RPM-E-0 Cooling Module RPM-E-00 Cooling Module Manufactured By Energy Saving

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

Parts List * October 2013

Parts List * October 2013 Parts List * October 2013 Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM HE-Z Series High Velocity Fan Coil LV-Z Series Conventional Replacement JH Series Space

More information

Mini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils

Mini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils Mini Duct Heating and Air Conditioning Indoor Air Quality Systems July 2008 Parts List Featuring: TM Also Including: Lo-Velocity Systems JH Fancoils Minimum Invoice Amount of $25 Net in Effect ESP 100.02b

More information

HE-B Series Commissioning Report & User Guide

HE-B Series Commissioning Report & User Guide Small Duct High Velocity Heating, Cooling and Home Comfort Systems HE-B Series Commissioning Report & User Guide Manufactured By www.hi-velocity.com Module-HEB-COM-Commissioning-Report-and-User-Guide-061616

More information

Commercial Applications

Commercial Applications Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM Commercial Applications Manufactured by Module-COM-Commercial-Applications-Brochure-042116 The Hi-Velocity System is a Complete

More information

Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems

Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems www.hi-velocity.com 2010 Parts List Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM Also Including: LV-E Systems JH Fancoils Hi-Velocity Air Purification System PWM

More information

R Series Cooling Modules

R Series Cooling Modules R Series Cooling Modules Models RCM/RPM 50 RCM 70 RM 100 RM 140 Manufactured By Energy Saving Products Ltd. Standard ESP 105.03 Refrigerant Modules (RCM/RM) Fig. 02 - Mounting brackets The cooling coil

More information

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right

More information

AirPurification System

AirPurification System The AirPurification System Installation and Operation Manual ONE SIZE FITS ALL! ESP 109.01 TABLE OF CONTENTS PARTS LIST........................................ 1 IMPORTANT SAFETY INSTRUCTIONS...................

More information

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209 INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F*FP ISO 9001 ertified Quality Management System SAFETY................................................1 SPEIFI SAFETY RULES AND PREAUTIONS...............2

More information

Z24 Wireless Zone Controller Professional Installation Guide

Z24 Wireless Zone Controller Professional Installation Guide Pelican Wireless Systems Pelican Wireless Systems Wireless Zone ontroller Professional Installation Guide Pelican Wireless Systems, 2655 ollier anyon Rd. Livermore, A 94551 Phone: 888.512.0490 Email: support@pelicanwireless.com

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams E1 Electrical Fundamentals # 4 - Symbols and Wiring Diagrams Loads Electrical Loads onsume electricity Do work Examples: Motors Solenoids Heaters Lights 2005 Refrigeration Training Services - E1#4 Symbols

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409 TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal

More information

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409 INSTALLATION MANUAL SINGLE PIEE AIR HANDLERS MODELS: F6FP018** - 060** ISO 9001 ertified Quality Management System SAFETY................................................ 1 SPEIFI SAFETY RULES AND PREAUTIONS...............

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact

More information

Installation Instructions HEAT COOL FAN POWER

Installation Instructions HEAT COOL FAN POWER DIGITAL THERMOSTAT Installation Instructions P/N P474-2300RE MULTI-STAGE & PUMP WIRELESS REEIVER Use with most Air onditioning & Heating Systems including: 1 or 2 Stage Electric ooling & Gas Heating, Heat

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL MODULA VAIABLE SPEED AI HANDLES MODELS: MV ISO 9001 ertified Quality Management System GENEAL.............................................. 1 SAFETY................................................

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C) TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

Premier 2-Zone Controller model Installer Guide

Premier 2-Zone Controller model Installer Guide Premier 2-Zone ontroller model 140202 Installer uide ONTENTS 1 Specifications 4 onfiguration 2 Suitable Mounting Locations 5 System heckout 3 Wiring Diagrams 6 Operation Warning Read all of the instructions

More information

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables. Nordic Technology Ltd 1-800-775-4750 www.fast-stat.com This is the printer-friendly edition. o to www.fast-stat.com to download and print additional copies HVA iring Solutions How to add or upgrade residential

More information

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J ProZone I n t e l l i g e n t Z o n i n g Zones See table below. ompatible Equipment All panels operate with gas/electric systems, conventional heat pumps and dual fuel heat pumps. Equipment Selection

More information

R Series Cooling Modules

R Series Cooling Modules TM Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems R Series Cooling Modules Models RCM-50 RCM-70 RM-100 Manufactured By Module-RCM/RM-Series-Installation-Manual-120113 Refrigerant

More information

Installation. Table of Contents. 1. Description/ Application. Form I-CAUA-CC (04-15) Obsoletes Form I-CAUA-CC (Version C.1)

Installation. Table of Contents. 1. Description/ Application. Form I-CAUA-CC (04-15) Obsoletes Form I-CAUA-CC (Version C.1) Form I-AUA- (04-15) Obsoletes Form I-AUA- (Version.1) Installation Applies to: ased ooling oil for Model AUA (either Model AU or Option ) Table of ontents 1. Description/Application...1 2. Uncrating and

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIEE VARIABLE SPEED AIR HANDLERS MODELS: AV*() SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS INSTALLATION AND OPERATION INSTRUTIONS 303, 304, 305, RH, RQ, FA SERIES 2250 WATT MODELS aution: To prevent electric shock disconnect power to heater at main service before wiring or service. aution: Do

More information

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.0 GENERAL SECTION 15740 SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.01 DESCRIPTION Item A. Scope This section specifies four sizes of fan coil units designed for hydronic heating and air conditioning.

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

LOW VOLTAGE CONTROL CIRCUIT WIRING

LOW VOLTAGE CONTROL CIRCUIT WIRING INSTALLATION INSTRUTIONS LOW VOLTAGE ONTROL IRUIT WIRING W**A W**AD WA*S* MODELS W**L WL*S* Bard Manufacturing ompany, Inc. Bryan, Ohio 506 Since 9...Moving ahead just as planned. Manual : 00-58 Supersedes:

More information

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h MBV Variable-Speed, omfortnet - ompatible Modular Blowers ooling apacity: 8,000-60,000 BTU/h Standard Features ompatible with the omfortnet ommunication System family of products Variable-speed EM blower

More information

ONX908FCT-4B/220V/RC FAN COIL THERMOSTAT

ONX908FCT-4B/220V/RC FAN COIL THERMOSTAT X0FCT-B/0V/RC FA COI THERMOSTAT Application: Heat/cool, speed fan, -pipe fan coil unit Installation and operation instructions SPECIFICATI: Electrical Rating 0VAC Terminal oad.0 A per terminal Set point

More information

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD 5.0 AI HANDLE omfort ontrol 2 System INTEFAE OAD FIGUE 8 THE AI HANDLE ONTOL OAD EQUIPPED WITH THE omfort ontrol 2 System The HPL-series of air handlers are designed to operate with conventional 24VA controls

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax: SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart

More information

HRV Vertical Unit Ventilators

HRV Vertical Unit Ventilators HRV Vertical Unit Ventilators lassroom Ventilators without Energy Recovery Installation, Operation and Maintenance Instructions Manual apacity: Up to 1,400 cfm Model: HRV450w, HRV1000w 2012 Venmar ES Inc.

More information

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC INSTALLATION MANUAL SINGLE PAKAGE HEAT PUMP/ELETRI MODELS: PHE4 Series (2-5 Ton) LIST OF SETIONS GENERAL INFORMATION................................ 1 SAFETY...............................................

More information

NAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections

NAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections NAH Series Air Handler Installation Information Water Piping onnections Electrical onnections Startup Procedures Preventive Maintenance NAH Series Hydronic Air Handler Installation Manual IM0H 0/ NAH

More information

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD 5.0 AI HANDLE EQUIPPED WITH THE OMFOT ONTOL 2 SYSTEM INTEFAE BOAD FIGUE 8 THE AI HANDLE OMFOT ONTOL 2 SYSTEM ONTOL BOAD The HPN-series of air handlers are designed to operate with conventional 24VA controls

More information

Installation Guide.

Installation Guide. Installation Guide www.evergreendealer.com www.thedealertoolbox.com When Regal Beloit acquired General Electric s Commercial and HVACR Motors and Capacitors businesses in 2004, it also acquired the rights

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8620 Thermostat with Event-Based Air leaning and Humidity or Ventilation ontrol Safety & Installation Instructions READ AND SAVE THESE INSTRUTIS Table of contents Installation Installation location

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

ECAH SERIES ECM AIR HANDLER

ECAH SERIES ECM AIR HANDLER ECAH SERIES ECM AIR HANDLER ECAH40 OPERATING MANUAL TABLE OF CONTENTS 1 GETTING STARTED... 3 2 ELECTRICAL CONNECTIONS... 3 3 DIMENSIONAL DATA... 4 4 PLUMBING... 5 4.1 OPEN SYSTEM... 5 4.2 CLOSED SYSTEM...

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15 AI HANDLE -0A efrigerant - Tons Submittal Data English Language/IP Units SD00HN 0/ ontractor: ENVISIN AI HANDLE - Tons Model Nomenclature - - - 0 NAH 0 * 00 0 Model NAH Envision Series Air Handler Unit

More information

Commercial Thermostat

Commercial Thermostat ommercial Thermostat Submittal Data *204* 204 ev.: November 18, 2016 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIEE, 3 POSITION EM AIR ANDLERS MODE: AV SERIES ISO 9001 ertified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

RE9X Series Downflow, Upflow Electric Furnaces

RE9X Series Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS RE9X Series Downflow, Upflow Electric Furnaces The RE9X Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL USERS INFORMATION MANUAL DOWNFLOW For Installation In: SINGLE AND TWO STAGE 1. Manufactured (Mobile) Home 2. Recreational Vehicle ELECTRIC FURNACE 3. Modular Homes & Buildings 4. Residential Homes MODELS:

More information

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6 9AB4-12 Air-ooled Remote ondenser Wiring Diagrams INDEX UNIT 9AB DRAWING TYPE DRAWING NUMBER FIG. NO. 4,6 Label Diagram 9AB6-10816 1 8,12 Label Diagram 9AB12-10816 2 AESSORIES OMPONENT PART NO. FIG. NO.

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET XE SERIES FA-COI THERMOSTATS -PIPE & -PIPE FA-COI COTRO APPICATIO The XE range of digital thermostats is designed for control of the fan, valves, compressor or auxiliary electric heater in fan-coil and

More information

RCM Refrigerant Module

RCM Refrigerant Module Small Duct High Velocity Heating, Cooling and Home Comfort Systems RCM Refrigerant Module Installation Manual Manufactured By Module-RCM-Refrigerant-Module-Installation-0666 Refrigerant Modules (RCM) Fig.

More information

Envision Air Handler Specification Catalog

Envision Air Handler Specification Catalog Air Handler Design Features Factory ptions Accessories Dimensional Data Physical Data Performance Data Engineering uide Specifications Envision Air Handler Specification atalog S00HN 0/ ENVISIN AI HANDLE

More information

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS R INSTALLATI/OPERATING INSTRUTIS SEQUENING PANELS SEQ-6, SEQ-6P and SEQ-12 Panels to Sequence up to 12 Individual Stages with Lead-Lag and Manual Override apabilities TENTS SEQ FUNTI HART... 2 DIP SWITH

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

SmartZone TM System Manual

SmartZone TM System Manual SmartZone TM System Manual Rev C3 June 1, 2007 Page 0 of 21 Table of Contents SmartZone TM System Manual Rev C3. April 23, 2007 Introduction..2 o Why Use Residential Zoning?..2 Architectural Challenges...

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

INSTALLATION MANUAL MODELS: E30 SERIES SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTALLATION MANUAL MODELS: E30 SERIES SAVE THIS MANUAL FOR FUTURE REFERENCE INSALLAION MANUAL DOWNFLOW SINLE AND WO SAE ELEI FUNAE WIH: FAO INSALLED ELEI HEA, O NO HEA MODELS WIH FIELD INSALLED ELEI HEA KIS MODELS: E0 SEIES LIS OF SEIONS eneral 7 Line Voltage and ontrol Box Wiring

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

GLAS. Installation Instructions

GLAS. Installation Instructions LAS Installation Instructions Support If at any point you need assistance, we re here to help. Visit www.glas.johnsoncontrols.com/support for how-to videos and frequently asked questions. an t find what

More information

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

1F98EZ-1421, Easy Install

1F98EZ-1421, Easy Install 1F98EZ-1421, -1441 Easy Install For up to 4 Stages and 2 Stages Cool INSTALLATION INSTRUCTIONS APPLICATIONS Configuration Options Single Stage Multi Stage Pump Pump with Dual Fuel FAILURE TO READ AND FOLLOW

More information

Installation Instructions

Installation Instructions H6HK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers IMPORTANT: The instructions included with this heater kit are for installations

More information

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left

More information

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications Installation Guide DIGIU Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications -Zone Controller for the RNC Market Part #DMAN October 004 Zoning Systems That s all we do. INTRODUCTION

More information

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil MDL SOLUTIONS Technical Catalogue NA Version PDWL AECM LSTAT Series Hydronic EC Ducted Fan Coil Hydronic Fan Coil Platform Introduction Company Introduction HVAC Solutions Sonkor Global MDL SOLUTIONS Technical

More information

SPECIFICATION CATALOG

SPECIFICATION CATALOG SPEIFIATIN ATAL ETHEMAL HEAT PUMPS AFFDABLE ENEWABLE LEAN ASTN SEIES AI HANDLE ASTN SEIES AI HANDLE SPEIFIATIN ATAL Table of ontents Air Handler Nomenclature...........................................................

More information

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE TEHNIAL UIDE MODELS: M9T-UP AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED ISO 9001 ertified Quality Management System Due to continuous

More information

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES TEHNIAL UIDE Echelon MODELS: F9M*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO MODULATIN FUNAES NATUAL AS 60-0 MBH INPUT EFFIIEN ATIN ETIFIED ISO 900 ertified Quality Management System Due to continuous product

More information

5 Series 500A11 Installation Manual

5 Series 500A11 Installation Manual 500A eothermal Heat Pump -40A efrigerant,.5,,.5,,.5, 4, 5, 6 Ton Single Speed,, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Hot Water enerator erator onnections 5 Series 500A

More information

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

EnviroZone-4 & EnviroZone-2 Quick-Start Guide EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

T4360G, T6360D, T6360E Line Voltage Thermostat

T4360G, T6360D, T6360E Line Voltage Thermostat T4360G, T6360D, T6360E ine Voltage Thermostat PRODUCT DATA FEATURES Models available for heat only, cool only and heat pump systems. Fan models for air circulation. Three-speed fan model to improve circulation

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

HI-VELOCITY SYSTEMS

HI-VELOCITY SYSTEMS INDEX ADD-ONS AND ACCESSORIES FILTER RACKS (WITH FILTER)... 2-5 HANGING STRAP KIT... 2-5 HI-VELOCITY AIR PURIFICATION SYSTEM ( PS)... 2-5 RETURN AIR BASE (WITH BUILT-IN FILTER RACK AND FILTER)... 2-5 COILS

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873 WIRIG GUIDE The ZSR101 is a versatile single relay control with two outputs for operating a 120 VAC with boiler enable, or two 120 VAC devices without boiler enable. Features include rear knock outs for

More information

TSTAT0101SC Recommended (order separately)

TSTAT0101SC Recommended (order separately) Up to 98% AFUE Communicating, Modulating Gas Furnace EASIER TO SELL 98% AFUE on G9MAC0602120, all positions 97% AFUE, all other models, all positions All Models have earned the ENERGY STAR Modulating heating

More information

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE TEHNIAL UIDE Echelon MODELS: F9T AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED Due to continuous product improvement, specifications

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed

More information

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning

More information