AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

Size: px
Start display at page:

Download "AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications"

Transcription

1 Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the air does not have to be as dry as when an air dryer is used" or "an air dryer cannot be used because an electric power supply is not available". Through the adoption of an element that is used exclusively for removing water drops and the provision of ample housing interior space, a % water removal rate has been achieved. Water separator can remove water droplets, but it cannot remove moisture. Condition of inlet air Pressure: 0.7MPa Temperature: 2 C Relative humidity: 0% Liquid water content (Water droplet content): 1.g/m 3 (ANR) Compressed air flow: Rated flow of each model Removed rate of water % = Removed water (Water droplet) g x 0 Inflowed water (Water droplet) g Various equipment for drain discharge (1) Flow rate (l /min (ANR)) Port size (Nominal size ) Weight (kg) Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient/Fluid temperature Removal rate of water Element life With N.O. auto drain: 0.1MPa Accessories (Options) Applicable model racket assembly With cap bolt With spring washer Note 1) Max. flow is at 0.7MPa. Max. flow depends on operating pressure. Please refer to p for flow rate and to p for graph of max. flow. How to Order E Compressed air 1.0MP 0.0MPa 1.MPa to 60 C % 2 years or when pressure drop reaches 0.1MPa M1 M2 M3 M4 M M6 M7 20 F 03 J ody size 10 1 / 20 1 / / 40 1 /2 0 3 / /2 Ordering source area code Japan, Asia - Australia E Europe N North America 1 /, 1 /4, 3 / 1 /4, 3 /, 1 /2 3 /, 1 /2, 3 /4 Thread Rc (PT) F G(PF) N NPT 01 1 / 02 1 / / 04 1 /2 Port size 3 / /2 2 1 /2, 3 /4, 1 3 /4, 1 1, 1 1 /2 1 1 /2, 2 Options J Drain guide 1 /4 female thread R IN-OUT reverse direction Accessories (Options) Symbol Description No accessories racket C N.C. auto drain D N.O. auto drain Please refer to the following table for combinations of accessories and options. Note) Please refer to p about "How to Order" case assembly. HA IDG AFF AM FQ1 Related products Symbol Option combinations Available Not available Accessories Options Applicable model Accessories/Optional specification C D J R N.C. auto drain C Accessories N.O. auto drain D Drain guide 1 /4 J Options IN-OUT reverse direction R 4.3-1

2 Series Flow Rate 10 Initial condition of element Note) If compressed air is above max. flow, water separator cannot operate well. 1 / 3 /4 Precautions e sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalogue, and refer to p.4.0- to for more detailed precautions of every series. Design 20 1 /4 1 qplace this product in a location that is not likely to create pulsations. If the internal/external pressure difference exceeds 0.1 MPa, the element could break. wwhen using an auto drain, drain pipes must be connected within the following range: Normally closed (N.C.) Normally open (N.O.) Tube fittings are provided. Therefore, use a mm external tube, and keep the pipe length within m. type (N.O.) Use a tube with a minimum bore of mm, and keep its length within 2.m. When using a normally open (N.O.) auto drain, because the valve does not close until the air pressure becomes higher than 0.1MPa, the air could keep discharging from the drain discharge section of an air compressor with a small air discharge volume. Therefore, make sure to use a normally closed (N.C.) auto drain with a compressor under 3.7kW. ethe bracket that is provided with the product is for supporting the product itself. Separate supports must be provided for piping and other connection devices / 1 1 /2 Installation qverify the direction of the compressed air flow and the " " mark that indicates the inlet side of the product before connecting. It cannot be used with its direction reversed. 1 /2 wmake sure to install this product horizontally. If it is installed diagonally, sideways, or upside down, the drainage that was separated by the element will splash to the secondary side. Maintenance qthe element replacement period is when the pressure drop has reached 0.1MPa or 2 years have elapsed after it has been put into use, whichever comes first. wwhen it is time to replace the element, immediately replace it with a new element. Also replace the O ring and the gasket. ewhen using a product equipped with a drain valve, drain guide, or a ball valve, discharge the drainage before the drain fluid surface reaches the center of the sight glass. If it is not discharged properly, the drainage will flow out to the secondary side

3 Water Separator Series Construction 10 to Component Parts No. q w e Description ody Housing Sight glass Replacement Parts No. Description Material Element Resin r assembly NR With gasket, With O ring Material Aluminum die cast Aluminum die cast Tempered glass 10 -EL10 Remark Chromate treatment, Epoxy coating on inner surface : Aluminum casting 20 -EL EL30 Part No. -EL40 Note: Constructions show sight glass, but mounting position is different from actual position. Please refer to p and 4.3- about drawings for more detailed. -EL0 -EL60 -EL0 Max. Air Flow How to Select Follow the procedure given below to select the model in accordance with the inlet pressure and maximum air flow rate requirements. (Example) Inlet pressure : 0.6 MPa Maximum air flow rate: m 3 /min (ANR) qusing the "Max. air flow", find point A, at which the input pressure and the maximum air flow rate intersect. wto select one with the maximum air flow rate line that is located above the obtained intersecting point A, the model will be. Note) Make sure to select a model with the maximum air flow rate line that is located above the obtained intersection point. A model with the maximum air flow rate line that is located below the obtained intersection point will have an excess flow rate, and will not satisfy the specifications. HA IDG AFF AM FQ1 Related products 4.3-3

4 Series 10 to Dimensions Accessories D: With auto drain (N.O. Type) C: With auto drain (N.C. Type) N.C. type of is not available. Options J: With drain guide Port Size (Nominal size ) 1 /, 1 /4, 3 / 1 /4, 3 / 1 /2 3 /, 1 /2 3 /4 1 /2, 3 /4 1 3 /4, 1 1, 1 1 /2 A C D E F G H I J K 1 Mounting Dimensions L M N O P Q R S

5 Water Separator Series Dimensions Accessory D: With auto drain (N.O. type) for HA IDG AFF AM FQ1 Related products Port size (Nominal size ) 1 1 / 2, 2 A C 34 D 2 E 7. F 2 G H 463. I 10 J 30 K 1 Mounting Dimensions L 24 M 13 N 1 O 14 P 2 Q 1 R 1 S

6 Series Made to Order Specifications Consult SMC for detailed specifications, size and delivery. Order Made qwith IN-OUT flange Available for flange piping easily. Specifications Applicable to How to Order : Refer to p for "How to Order" standard specifications. X1 ody size Optional specifications Thread Accessories Port size Dimensions Connection 3/4, FF, K 1, FF, K 1 1/2, FF, K 2, FF, K A

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

% by up ctoond re-heater and

% by up ctoond re-heater and Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA

More information

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow

More information

Drain Separator for Vacuum

Drain Separator for Vacuum Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available! Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

VD 53 - Vacuum drying oven for non-flammable solvents

VD 53 - Vacuum drying oven for non-flammable solvents Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Refrigerated Air Dryer Large Size Series

Refrigerated Air Dryer Large Size Series Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Large Size Series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 Inlet air temperature 60 Energy

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,

More information

General Purpose Ventilation Fan - Venturi-Style Blower PSIG

General Purpose Ventilation Fan - Venturi-Style Blower PSIG General Purpose Ventilation Fan - Venturi-Style Blower - 3752 CFM @ 90 PSIG Part #: GPF-3752 Page: 1 Page: 2 Made in the USA The Larson Electronics GPF-3752 General Purpose Ventilation Fan is designed

More information

DRYAIRE DESICCANT SYSTEM MODEL 6760

DRYAIRE DESICCANT SYSTEM MODEL 6760 MODEL 6760 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance for removing dirt, water, oil, and

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

PuraGuard. Maintenance Kit Rebuild Kit Replacement Drain Cock

PuraGuard. Maintenance Kit Rebuild Kit Replacement Drain Cock Air Dryers 08 PuraGuard PuraGuard Service Pc. No. 800691 One Supply & one Delivery Port (see arrow symbol on PuraGuard top cover for air flow) Maintenance Kit...5006788 Rebuild Kit...5006789 Replacement

More information

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION METERS AND GAUGES FOR HVAC PIPING SECTION 23 05 19 - METERS AND GAUGES FOR PART I GENERAL 1.1 SECTION INCLUDES A. Thermometers B. Pressure Gauges C. Pressure/Temperature (P/T) Plugs D. Venturi Flow Elements 1.2 RELATED SECTIONS A. Section

More information

OIL SEPARATORS APPLICATIONS

OIL SEPARATORS APPLICATIONS OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1 and are subject

More information

DIRTCAL - DIRTMAG dirt separator

DIRTCAL - DIRTMAG dirt separator 864.07 www.caleffi.com DIRTCAL - DIRTMAG dirt separator Copyright 206 Caleffi 5462-546 -5465-5465M - NA5465 - NA5465M Series Installation, commissioning and servicing instructions Function In heating and

More information

HITACHI BEBICON AIR COMPRESSORS TANK MOUNT BEBICON PACKAGE BEBICON OIL FREE SCROLL AIR COMPRESSORS

HITACHI BEBICON AIR COMPRESSORS TANK MOUNT BEBICON PACKAGE BEBICON OIL FREE SCROLL AIR COMPRESSORS HITACHI BEBICON AIR COMPRESSORS TANK MOUNT BEBICON PACKAGE BEBICON OIL FREE SCROLL AIR COMPRESSORS TWO MILLION accumulative shipments High quality and reliability with long history 1 HITACHI is one of

More information

Moisture Control Tube

Moisture Control Tube Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) -80 www.cmafh.com Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Drain Cleaning Machine K-39

Drain Cleaning Machine K-39 Drain Cleaning Machine K- 0 A- AUTOFEED Cable Chuck Pan Head Screw #0 - () Chuck Adapter Nose Piece Spiral Ring () Hand Grip Sleeve Clamp Springs () See Service Notes 0 Spacer Clips () Gasket Drum Front

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

Pressure Switches Precautions 1 Be sure to read this before handling.

Pressure Switches Precautions 1 Be sure to read this before handling. Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate

More information

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Standard Type ±.1 C New HRS5 New HRS6 (UL Standards) RoHS HRS12/18/24 New HRS3 Same width for all models:

More information

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail Drain Cleaning Machine K-0 Motor/Frame Assembly 0 0. Position Fan as Shown. Fan Mounting Detail Frame Assembly 0 Screw #0 - () Rubber Foot () 0 Carriage Bolt /" - x /" Flange Bearing () 0 Bracket 0 /"

More information

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6 OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...

More information

CKD refrigerating type dryer

CKD refrigerating type dryer CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

CL64T INDUSTRIAL TOTE WASHER

CL64T INDUSTRIAL TOTE WASHER Item # Quantity C.S.I. Section 11400 STANDARD FEATURES Selectable Speed 4, 5, 6 feet/minute Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock switches

More information

REVISED AIR GOVERNOR LINES CX AND CH MODEL CHASSIS WITH ASET AC ENGINE

REVISED AIR GOVERNOR LINES CX AND CH MODEL CHASSIS WITH ASET AC ENGINE SERVICE BULLETIN (Not applicable to Mack Trucks Australia) NUMBER: SB-531-011 DATE: 7/12/04 MODEL: CX, CH REVISED AIR GOVERNOR LINES CX AND CH MODEL CHASSIS WITH ASET AC ENGINE Effective June 2004, stainless

More information

CFH Series High Efficiency Filters

CFH Series High Efficiency Filters CFH Series High Efficiency Filters Intelligent Air Technology Save energy, dollars & protect your air system The Compressed Air Challenge, a government/ industry sponsored energy savings awareness program,

More information

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. W1860BE.book Page 12 Tuesday, January 28, 2003 11:01 PM 2. Cooling System A: COMPRESSOR The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. As the rotor

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

ODIN Backwash UNIT Installation Instructions

ODIN Backwash UNIT Installation Instructions ODIN Backwash UNIT Installation Instructions Contents Before installation Content of packaging Installation of Shampoo Unit 1.Assembling the Bowl 2.Fixing the Bowl 3.Fixing the Main Unit of Floor 4.Piping

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

UNIVERSAL SOLVENT HEATER

UNIVERSAL SOLVENT HEATER UNIVERSAL SOLVENT HEATER Circulation Heater A cast-in circulation heater with a full array of special features to safely heat volatile solvents. The Universal Solvent Heater from Cast Aluminum Solutions

More information

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Advanced Laundry Chemical Dosing System for Single and Multi-Washers Advanced Laundry Chemical Dosing System for Single and Multi-Washers The On-Premise Elite sets the new standard for laundry chemical dosing systems by which all others will be measured! Innovative smart

More information

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure Instructions Parts List Air Dryer 307548H Model 217341 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure Removes oil and other contaminants from compressed air, then dries the air to 45 F

More information

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts Worldwide Contacts www.tyco-fire.com Model CV-F Grooved End Swing Check Valves General Description The TYCO Model CV-F Grooved End Swing Check Valves are compact and rugged swing-type units that allow

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL MOUNTED)

More information

Karman Vortex Flow Meter KSL-5/10/30/50LN

Karman Vortex Flow Meter KSL-5/10/30/50LN Karman ortex Flow Meter KSL-5/1/3/5LN Karman ortex System Flow Sensor KSL-5L/KSL-1L/KSL-3L/KSL-5L Features s a sensor for monitoring the cooling water of equipment, a cumulative total of 6, units have

More information

General Specifications

General Specifications General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density

More information

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09 Installation & Maintenance Instructions Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09 GENERAL OPERATION The Smart Guard Ultra is a zero-air-loss, electronic level sensing condensate drain. By

More information

Prevents condensation

Prevents condensation Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 3099D Model 30 Maximum Operating Pressure 0 psi (. MPa, bar) Maximum Temperature 50 F (5 C) Includes: Part No. Description 30 Stage - Air Filter with

More information

CLEARPOINT Heater. Compressed Air Filter Heater Based on Ohm Resistance

CLEARPOINT Heater. Compressed Air Filter Heater Based on Ohm Resistance Compressed Air Filter Heater Based on Ohm Resistance Function CLEARPOINT S055TWC Design CLEARPOINT Filter housing parts (aluminum) Electric housing (plastic) Bottom part (brass), heating elements and casing

More information

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance

More information

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS IB 835 Installation Manual Integrated Bidet Toilet Cautions before installation Water supply should have a minimum water pressure of 10 psi For smooth drainage, water pressure must stay at its required

More information

Hose Clamps, Charge Air Cooler, Replacement page 2

Hose Clamps, Charge Air Cooler, Replacement page 2 Volvo Trucks North America Greensboro, NC USA DService Bulletin Trucks Date Group No. Page 5.2008 265 24 1(9) Hose Clamps, Charge Air Cooler, Replacement D11F, D13F and D16F Cummins ISX Hose Clamps, Charge

More information

VALVES SECTION 15100

VALVES SECTION 15100 VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common

More information

Dual Pressure Controls

Dual Pressure Controls PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features 197 Safety Precautions 199 Secondary Air Flow Rate, Secondary Air Dew Point, and Pressure Drop 201

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

Liquid Drainers LIQUID DRAINERS

Liquid Drainers LIQUID DRAINERS Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG

More information

Automatic Condensate Drains ECO DRAIN Series

Automatic Condensate Drains ECO DRAIN Series Automatic Condensate Drains ECO DRAIN Series For compressor capacities up to 1,700 m³/min series Electronic condensate drain Condensate is an unavoidable result of air compression. If not reliably drained

More information

SECTION METERS AND GAGES FOR HVAC PIPING

SECTION METERS AND GAGES FOR HVAC PIPING SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type

More information

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC. NORTH AMERICAN ADVANCED TECHNOLOGIES, INC. WSS-W Core-extractable protective bimetal thermometer (Adjustable angle, Back, Bottom Connected) WSSX-W Gear style core-extractable protective bimetal thermometer

More information

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER: MK-00 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS CAUTION: Read all safety and operating instructions before using this equipment Enter the Serial Number of your new saw in the space

More information

XTREME ICE MAKER (1230 SERIES)

XTREME ICE MAKER (1230 SERIES) XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE (0) of Manual Part No. 00IPL 00 IMI Cornelius Co., 00 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00

More information

Davies Carries Parts for MF & SF Series Glycol Feeders

Davies Carries Parts for MF & SF Series Glycol Feeders Chemical Bypass Feeders B24 Feeders Delivers chemicals to any closed loop system. Maintaining a chemically balanced hydronic system has never been easier Allows for safe and easy chemical dosing. Ball

More information

Compressors, Chillers & Condensers

Compressors, Chillers & Condensers Totaline s water-cooled condensers are designed for a wide range of applications and are available in many models ranging from 5 to 400 nominal tons. Small and large condensers are available for fresh

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Grinder Pumps KGP(X) 7.5-15HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) (PENDING) The KEEN PUMP KGP(X) series centrifugal grinder pumps are designed for municipal, commercial

More information

Model FDT FDT A FDT FDT A FDT FDT A FDT FDT A. Model DMP DMP DMP DMP

Model FDT FDT A FDT FDT A FDT FDT A FDT FDT A. Model DMP DMP DMP DMP ontrol Series Fiber Dry FDT Dry unit (Filter, ) L 2 2 2 2 φ 25.5 (M5 Attachment) L2 5 2 27 3 22.5 7 FDT FDT A FDT FDT A FDT FDT A FDT FDT A L L2 9.5 2.5 2.5 9 7 2.5.5 22 2 3 3 9 9 DMP 3 22.5 25.5 (M5 Attachment)

More information

HIGH PRESSURE DOUBLE CASE PUMPS

HIGH PRESSURE DOUBLE CASE PUMPS HIGH PRESSURE DOUBLE CASE PUMPS Horizontally Split Inner Casing, Multi Stage For Boiler Feed, Process and Other High Pressure Services CS1860EE Models HSB/HDB API 610 HIGH PRESSURE DOUBLE CASE PUMPS Horizontally

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure

More information

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Hollow Fiber Membrane Filter Type Air Drier Unit Type http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Drier Unit Type Dry Unit 202 No electric power supply is required. Air Filter, Mist

More information

Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209 Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts uel Manager Diesel uel iltration M1, M10, M100 and M1000 Complete Systems, s and Service Parts uel Manager diesel fuel filter/water separator systems are used globally in a wide variety of diesel engine

More information

A HEATER KIT With Diesel Engine Connection Fittings

A HEATER KIT With Diesel Engine Connection Fittings A-12142 HEATER KIT With Diesel Engine Connection Fittings Figure 1 (General Layout and Parts I.D.) Page 1 of 6 Read these instructions and identify all components. Please retain these instructions for

More information

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do

More information