1 Part 2 Price Bid

2 BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT SR.NO. DESCRIPTION OF ITEMS QTY UNIT RATE AMOUNT A SITC of High Wall Air Conditioners 1 SITC of air cooled HIGH WALL MOUNTED Type air conditioning units as specified; each unit shall comprise of separate Indoor and outdoor unit specified and as under: Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row Deep DX coil with finned copper tubes, T-Flow Fan unit with direct drive Motor; Unit shall have proper insulated & leak proof condensate base connected. The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly installed on suitable vibration isolators and comprising of energy efficient Rotary / Reciprocating compressor with copper condensor The units shall be installed on MS angle iron frame welded structure (Sepatate item) with duly with anti-corrosive paint (Expoxy) - Vibration Isolated pad with 2 side GI sheet. The above specified units shall be supplied as per following schedule installed at locations as mentioned in the layout The unit will comparising of suitable electrcial panal with capactior connector strip clamps etc Tr. HI - Wall Mount Split AC units - 5 star rating 2.00 NOS Tr. HI - Wall Mount Split AC units - 5 star rating 1.00 NOS 2 SITC of Ceiling Suspected Cassatte type split Ac unit Supply, installation, testing & commissioning of microprocessor based air cooled casstte type air conditioning units as specified; each unit shall comprise of separate indoor and outdoor unit specified and as under: Indoor (fan coil) unit shall be suspended type comprising of fan,four way air discharge and 2 row deep dx coil with finned copper tubes, centrifugal fan unit with motor; unit shall have proper insulated and leak proof condensate base connected to drain piping with suitable temperature controller, fault indicator, fan motor speed selection, real time clock, driect drive fan motor and forward curve fan, drain pump and with magnatic type water level controller. The outdoor (condensing unit) shall be of corrosion resistant galvanized powder coated or equivalent sheet steel low vibration assembly installed on suitable vibration isolators & comprising of energy efficient scroll / rotary compressor with controls such as overload protactor, suction & liquid valve & factory charge refrigenert (r22) The above specified units shall be supplied as per following schedule installed at locations as mentioned in the layout The unit will comparising of suitable electrcial panal Tr 4-way cassette type AC with srcoll compressor NOS 3 Installation, machine erection with copper piping, hard cpvc drain line & electrical control wiring up to 4.5 mtr. Per circuit including SFu unit with top & plug if required for indoor unit. For Casstte and Concealed indoor unit should hang with help of clit with 4 nos, 10 x 50 mm long fastner and suitable rod. 3.1 Installation of 1.0 / 1.5 / 2.0 tr. High wall spilt 3.00 NOS 3.2 Installation of 3.0 tr. Casstte type spilt Unit 4 Condensate DRAIN Piping UPVC Drain Piping Duly Insulated with 9 MM Nitrile Rubber and BOPP Tape of following size DIA (if Require) MM RMT MM RMT Architect: Devdatt M Pandya M/S "Studio 919 Architects"

3 BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT SR.NO. DESCRIPTION OF ITEMS QTY UNIT RATE AMOUNT 5 Refrigerant copper piping to be insulated with 13 mm elastomeric nitrite rubber insulation Class 'O'. Aluminum foil membrane shall be applied to provide resistance against breakdown due to uv radiation for exposed portion of the rubber insulation. 5.1 Providing & fixing refrigerant copper pipe for 1.0 /1.5 / 2.0 Tr Wall mounted split unit (beyond 4.5 mtr. / circuit) 5.2 Providing & fixing refrigerant copper pipe for 2.8 Tr / 3.0 Tr / 4.0 Tr Casstte unit (beyond 4.5 mtr. / circuit) 6 Sitc of electrical power 4c x 2.5sqmm, FRLS type of havels / polycab / RR / KE1 make cabling and control wiring in pvc conduit & saddling at min. 3 rft (appropriate for each machine) (only at one place power will be made Available) (measurment will total for single cable i.e from panal for outdoor or panel to indoor unit will be measure as single cable. No sepeate measument for control, power, hp / lp or fan motor) 6.1 Providing & fixing Electrical ISI cable for 1.0 /1.5 / 2.0 Tr Wall mounted split unit (beyond 4.5 mtr. / circuit) 6.2 Providing & fixing Electrical ISI cable for 2.8 / 3.0 Tr Casstte unit (beyond 4.5 mtr. / circuit) RMT RMT 7 Weather proof Treatment with GC cloth & UV paint RMT suitable to nitrile rubber Exposed pipe insulation 8 UNIT STAND Out door unit to be wall mounted on suitable stand made of fabricated Angle/Sheetmetal with rubber pads, m.s. cage for locking of out door unit as per the drawing provided by Architect NOS 9 REMOVING & REFIXING OF EXISTING A.C. Removing & Refixing of Existing Old ACs Handlling of AC, with Gas Charging & Overhaul Servicing all including.as per site requirements within the old premises to new premises NOS 10 All sort of civil work required to be executed in order to make the a.c. system installed & put in working condition. The item includes, making halls / gaps in walls, making zaries required for various types of drain, referegerent & drain water pipes / lines in walls, floor etc. Using cutter machine, refinishing on both side the same with reach cement mortar to match the surrounding surfaces & put entire work with proper finishes. TOTAL AMOUNT % DISCOUNT IF ANY 1.00 LOT BUY BACK SPLIT AC 1.0 / 1.5 / 2.0 TR 2.00 NOS Window AC 2.00 NOS GRAND TOTAL Net Tender Amount in words Rupees' Architect: Devdatt M Pandya M/S "Studio 919 Architects"

4 LIST OF APPROVED MAKE SR. NO. EQUIPMENT / MATERIAL MAKES 1 VRF / VRV Units Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 2 Cassaatte Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 3 Ductable Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 4 Split Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 5 Copper Pipe Mandev / Rajco / Totaline 6 Hard PVC Pipe Supreme / Prince 7 GI Sheet Tata / Jindal / Essar / Nippon 8 Acoustic Insulation Armasound (Arma cell) / Equivalent 9 Thermal Insulation Material a) Nitrile Rubber Armaflex / K Flex / Equival b) Thermocole Breadshell / Equivalent 10 Cable a) Armored Cable Finolex / Universal / Ploycab / RR Kable b) Flexible Cable Finolex / Universal / Ploycab / RR Kable 11 PVC Rigid conduits & Accessories 2.0mm thick Precision Plastic co. ISI and FIA approved

5 LVL: +9'-0" " 1' 8'-7" 1' UP 15'-10" 5' 5' 4'-2" 30' 2'-1" 1-7" 1' -5" 21'-5" 12' 2.0tr 4'-2" 2'-1" SWAYAM ECD E LOBBY 10'-0"X 15-0" CDM ATM 5' 9' " 2' 4'-8" 7' 2' 9' 1.0tr -6" 4'-9" 5'-7" 1.0tr PROPOSED LAYOUT of "JASDAN " BRANCH, STATE BANK OF INDIA NOTE : * ALL DIMENSIONS ARE TO BE READ, NOT TO BE MEASURED. *ALL DIMENSIONS ARE IN FEET - INCHES * BEFORE STARTING CONSTRUCTION, THE CONTRACTOR/SUB CONTRACTOR SHALL REVIEW AND VERIFY. ALL DRGS,DIMENSION AND CONDITIONS, DISCREPANCIES. IN THE DRGS, OR IN BETWEEN THE DRGS AND ACTUAL. FIELD CONDITIONS SHALL BE REPORTED TO THE ARCHITECTS BEFORE STARING CONSTRUCTION. * THE ARCHITECTS SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR/ SUB CONTRACTOR COMPLIANCE WITH SAFETY AND REGULATION. *ANY AMBIGUITY FOUND, CONTACT ARCHITECT / INTERIOR DESIGNER BEFORE EXECUTION. * DWGS. ARE PROPERTY OF "STUDIO 919 ARCHITECTS"& SHALL NOT BE COPY WITHOUT PERMISSION SBI-JASDAN 01 NTS SHAILESH DEVDATT Architect Interior Designer DEVDATT PANDYA SHAILY SHUKLA PANDYA STUDIO 919 2nd Flr. - 8, AJITNATH SOC., Nr. PALDI P.O., AHMEDABAD , INDIA. TELEFAX: , 919studio@gmail.com

TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS.

TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS. BILL OF QUANTITIES FOR AIR CONDITIONING WORKS S.N. DESCRIPTION QTY UNIT VENTILATION & AIR CONDITIONING A HIGH SIDE WORKS (SUPPLY OF EQUIPMENTS) 1 DX TYPE SPLIT AIR-CONDITIONERS: Supply of Aircooled Split

More information

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21 SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21 PART B : PRICE BID TENDER FOR: PROPOSED AIR CONDITION WORKS OF SHIFTING

More information

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID For the work of : SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL INVITES TENDERS ON BEHALF OF SBI, A.O.,INDORE THROUGH E-TENDERING PROCESS. PROPOSED AIRCONDITIONING WORKS OF SBI M.G.ROAD

More information

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD. SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD. (A Wholly Owned Subsidiary of SBI) CIRCLE OFFICE: 4TH FLOOR, SBI LOCAL HEAD OFFICE III/1-PANDIT J N MARG, KHARAVELA NAGAR BHUBANESWAR, ODISHA-751001 Part-II PRICE

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No. Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi -110003, Ph. No. 011-49854100 TENDER NOTICE Sealed tender in two separate bids a) Technical bids,

More information

Water Chiller Solutions. A solution to every water cooling need.

Water Chiller Solutions. A solution to every water cooling need. Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,

More information

TENDER DOCUMENT FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING SYSTEM FOR NEW SERVER ROOM AT TAKSHASHILA BUILDING

TENDER DOCUMENT FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING SYSTEM FOR NEW SERVER ROOM AT TAKSHASHILA BUILDING TENDER DOCUMENT FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING SYSTEM FOR NEW SERVER ROOM AT TAKSHASHILA BUILDING Tender No: IIT/CIC/NEW-SERVER-ROOM/AC/2017-18/26, Dated: 05.10.2017

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

VOLUME 2 (BOQ & Price Bid)

VOLUME 2 (BOQ & Price Bid) TENDER DOCUMENT NIT No: PAT/CON/721/01 FOR Tender for Supply, Erection & Commissioning of Refrigeration Plant for chilled water system for Ice-Cream mix section complete for 20 KLPD Ice Cream Plant at

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

TOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING

TOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND SR. Description QTY UNIT GROUP A AIRCONDITIONING 1 Supplying and erecting split type room Airconditioning unit 1.5 TR 3/5 star capacity 230/250V,

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

TENDER NOTICE. Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur

TENDER NOTICE. Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur TENDER NOTICE Sealed Tender offers are invited for supply, installation & commissioning of Fire Hydrant System at our Gokul Dairy Project Complex at Gokul Shirgaon Kolhapur. Only contractors having valid

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E A 1 2 4 PUMP HOUSE: BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E Supply, erection,testing & commissioning of Single stage, end suction / back pull-out type motor driven Jockey Pump of capacity 10.8

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 119/IWD/ED/644 SCHEDULE OF QUANTITY Name of work: Electrical work for: Part-A: Rewinding, overhauling and repairing of ceiling fan and exhaust fan installed

More information

SCHEDULE FOR AIR CONDITIONING WORK FOR NAC BUILDING FIRST FLOOR.

SCHEDULE FOR AIR CONDITIONING WORK FOR NAC BUILDING FIRST FLOOR. A) AIR-CONDITIONING SYSTEM 1.0 Air Cooled Ductle Split Ac Supply of INVERTER split type Hi-sttic Ductle unit nd ir cooled outdoor condensing units with Inverter scroll compressor, condenser fn,outer csing

More information

LONG LINE SET APPLICATION R-410A

LONG LINE SET APPLICATION R-410A LONG LINE SET APPLICATION R-410A TECHNICAL PUBLICATION TP-107K Goodman Company, L.P. INDEX SECTION 1. General Requirements for All Long Line Set Applications... 2 SECTION 2. Outdoor Unit and Indoor Unit

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

SECTION FAN COIL UNITS

SECTION FAN COIL UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units)

Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units) Rayat Shikshan Sanstha s Karmaveer Bhaurao Patil Mahavidyalaya, Pandharpur, Dist-Solapur - 4133304 Ph : 02186-223104 TENDER FORM Email : kbppandharpur@gmail.com Date : 12-08-2017 A] General Information:

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series

High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series NEW UNIQUE LCD CONTROLLER THE VOLTAS INTELLISYS RANGE Aero, Thermo and Tropico Series are High-performance Packaged & Ductable

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) INVITES RATE CONTRACT TENDER FOR

SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) INVITES RATE CONTRACT TENDER FOR NIT NO 68 /18 Date 19.06.2018 SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) INVITES RATE CONTRACT TENDER FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF HIGH WALL SPLIT,

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TENDER DOCUMENT NIT No.: DLI/C&E/WI-675/290 FOR Tender for Design, Engineering, Supply, installation, testing and commissioning of PACKAGE AIR CONDITIONING (PAC) SYSTEM AND ASSOCIATED WORKS for the project

More information

DESIGN GUIDELINES SECTION HVAC

DESIGN GUIDELINES SECTION HVAC 3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume

More information

Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES

Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING ILLS OF QUANTITIES 26/10/2015 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR SERVER ROOM The air conditioning

More information

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

PART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM

PART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM 1 PACKAGE AIR CONDITIONER UNITS 1.1 Monthly PM of Flame Proof for Analyzer House Air Conditioner Units at various locations.job includes but not limited to attending all complaints & rectifying the problems,

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector

More information

1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT

1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT A MAIN PANEL/DB 1 Supply and Installation of main LT panel, floor mounted, front operated dead back, totally enclosed vermin proof, indoor, non drawout, cubicle type power dist. panel fabricated out of

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI FIRE PROTECTION 1 G.I.PIPES Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 3589 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD. i 1 a SPRINKLER SYSTEM M S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports malleable srewed specials such as M S Reducers,Tees, elbows, flanges. Including cutting,

More information

2. CURRICULUM. Sl. No.

2. CURRICULUM. Sl. No. . CURRICULUM Sl. No. Code Title No. of Lecture Hours 1 RAC 001 Fundamentals of Refrigeration and Air 60 conditioning RAC 00 Psychrometry, Heat load Estimation for 70 Air conditioning and Refrigeration

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder Software Technology Parks of India - Pune (An Autonomous Society under Govt. of India, Ministry of Communications & Information Technology, Department of Electronics and Information Technology), Plot no.p-1,

More information

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil. 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG: Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Ductable Range of Air Conditioners

Ductable Range of Air Conditioners Ductable Range of Air Conditioners The world is witnessing growth at a breakneck speed. The upsurge in economic and social activities has led to rampant use of natural resources like water, minerals, energy,

More information

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES SECTION 15830 HEATING & COOLING TERMINAL UNITS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All fan coil units shall be sized to meet design load while operating at medium speed. In extreme noise sensitive

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for SUBMITTAL DATA for STOCK ROOFTOP UNIT AS ORDERED - PLEASE CHECK AND SIGN AS APPROVED Prepared for Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV 6301 Customer PO#: 38 Prepared by Mason and

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information