BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT
|
|
- Joella Morton
- 5 years ago
- Views:
Transcription
1 Part 2 Price Bid
2 BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT SR.NO. DESCRIPTION OF ITEMS QTY UNIT RATE AMOUNT A SITC of High Wall Air Conditioners 1 SITC of air cooled HIGH WALL MOUNTED Type air conditioning units as specified; each unit shall comprise of separate Indoor and outdoor unit specified and as under: Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row Deep DX coil with finned copper tubes, T-Flow Fan unit with direct drive Motor; Unit shall have proper insulated & leak proof condensate base connected. The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly installed on suitable vibration isolators and comprising of energy efficient Rotary / Reciprocating compressor with copper condensor The units shall be installed on MS angle iron frame welded structure (Sepatate item) with duly with anti-corrosive paint (Expoxy) - Vibration Isolated pad with 2 side GI sheet. The above specified units shall be supplied as per following schedule installed at locations as mentioned in the layout The unit will comparising of suitable electrcial panal with capactior connector strip clamps etc Tr. HI - Wall Mount Split AC units - 5 star rating 2.00 NOS Tr. HI - Wall Mount Split AC units - 5 star rating 1.00 NOS 2 SITC of Ceiling Suspected Cassatte type split Ac unit Supply, installation, testing & commissioning of microprocessor based air cooled casstte type air conditioning units as specified; each unit shall comprise of separate indoor and outdoor unit specified and as under: Indoor (fan coil) unit shall be suspended type comprising of fan,four way air discharge and 2 row deep dx coil with finned copper tubes, centrifugal fan unit with motor; unit shall have proper insulated and leak proof condensate base connected to drain piping with suitable temperature controller, fault indicator, fan motor speed selection, real time clock, driect drive fan motor and forward curve fan, drain pump and with magnatic type water level controller. The outdoor (condensing unit) shall be of corrosion resistant galvanized powder coated or equivalent sheet steel low vibration assembly installed on suitable vibration isolators & comprising of energy efficient scroll / rotary compressor with controls such as overload protactor, suction & liquid valve & factory charge refrigenert (r22) The above specified units shall be supplied as per following schedule installed at locations as mentioned in the layout The unit will comparising of suitable electrcial panal Tr 4-way cassette type AC with srcoll compressor NOS 3 Installation, machine erection with copper piping, hard cpvc drain line & electrical control wiring up to 4.5 mtr. Per circuit including SFu unit with top & plug if required for indoor unit. For Casstte and Concealed indoor unit should hang with help of clit with 4 nos, 10 x 50 mm long fastner and suitable rod. 3.1 Installation of 1.0 / 1.5 / 2.0 tr. High wall spilt 3.00 NOS 3.2 Installation of 3.0 tr. Casstte type spilt Unit 4 Condensate DRAIN Piping UPVC Drain Piping Duly Insulated with 9 MM Nitrile Rubber and BOPP Tape of following size DIA (if Require) MM RMT MM RMT Architect: Devdatt M Pandya M/S "Studio 919 Architects"
3 BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT SR.NO. DESCRIPTION OF ITEMS QTY UNIT RATE AMOUNT 5 Refrigerant copper piping to be insulated with 13 mm elastomeric nitrite rubber insulation Class 'O'. Aluminum foil membrane shall be applied to provide resistance against breakdown due to uv radiation for exposed portion of the rubber insulation. 5.1 Providing & fixing refrigerant copper pipe for 1.0 /1.5 / 2.0 Tr Wall mounted split unit (beyond 4.5 mtr. / circuit) 5.2 Providing & fixing refrigerant copper pipe for 2.8 Tr / 3.0 Tr / 4.0 Tr Casstte unit (beyond 4.5 mtr. / circuit) 6 Sitc of electrical power 4c x 2.5sqmm, FRLS type of havels / polycab / RR / KE1 make cabling and control wiring in pvc conduit & saddling at min. 3 rft (appropriate for each machine) (only at one place power will be made Available) (measurment will total for single cable i.e from panal for outdoor or panel to indoor unit will be measure as single cable. No sepeate measument for control, power, hp / lp or fan motor) 6.1 Providing & fixing Electrical ISI cable for 1.0 /1.5 / 2.0 Tr Wall mounted split unit (beyond 4.5 mtr. / circuit) 6.2 Providing & fixing Electrical ISI cable for 2.8 / 3.0 Tr Casstte unit (beyond 4.5 mtr. / circuit) RMT RMT 7 Weather proof Treatment with GC cloth & UV paint RMT suitable to nitrile rubber Exposed pipe insulation 8 UNIT STAND Out door unit to be wall mounted on suitable stand made of fabricated Angle/Sheetmetal with rubber pads, m.s. cage for locking of out door unit as per the drawing provided by Architect NOS 9 REMOVING & REFIXING OF EXISTING A.C. Removing & Refixing of Existing Old ACs Handlling of AC, with Gas Charging & Overhaul Servicing all including.as per site requirements within the old premises to new premises NOS 10 All sort of civil work required to be executed in order to make the a.c. system installed & put in working condition. The item includes, making halls / gaps in walls, making zaries required for various types of drain, referegerent & drain water pipes / lines in walls, floor etc. Using cutter machine, refinishing on both side the same with reach cement mortar to match the surrounding surfaces & put entire work with proper finishes. TOTAL AMOUNT % DISCOUNT IF ANY 1.00 LOT BUY BACK SPLIT AC 1.0 / 1.5 / 2.0 TR 2.00 NOS Window AC 2.00 NOS GRAND TOTAL Net Tender Amount in words Rupees' Architect: Devdatt M Pandya M/S "Studio 919 Architects"
4 LIST OF APPROVED MAKE SR. NO. EQUIPMENT / MATERIAL MAKES 1 VRF / VRV Units Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 2 Cassaatte Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 3 Ductable Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 4 Split Unit Daikin / Carrier / Hitachi / Mitsubishi / Toshiba 5 Copper Pipe Mandev / Rajco / Totaline 6 Hard PVC Pipe Supreme / Prince 7 GI Sheet Tata / Jindal / Essar / Nippon 8 Acoustic Insulation Armasound (Arma cell) / Equivalent 9 Thermal Insulation Material a) Nitrile Rubber Armaflex / K Flex / Equival b) Thermocole Breadshell / Equivalent 10 Cable a) Armored Cable Finolex / Universal / Ploycab / RR Kable b) Flexible Cable Finolex / Universal / Ploycab / RR Kable 11 PVC Rigid conduits & Accessories 2.0mm thick Precision Plastic co. ISI and FIA approved
5 LVL: +9'-0" " 1' 8'-7" 1' UP 15'-10" 5' 5' 4'-2" 30' 2'-1" 1-7" 1' -5" 21'-5" 12' 2.0tr 4'-2" 2'-1" SWAYAM ECD E LOBBY 10'-0"X 15-0" CDM ATM 5' 9' " 2' 4'-8" 7' 2' 9' 1.0tr -6" 4'-9" 5'-7" 1.0tr PROPOSED LAYOUT of "JASDAN " BRANCH, STATE BANK OF INDIA NOTE : * ALL DIMENSIONS ARE TO BE READ, NOT TO BE MEASURED. *ALL DIMENSIONS ARE IN FEET - INCHES * BEFORE STARTING CONSTRUCTION, THE CONTRACTOR/SUB CONTRACTOR SHALL REVIEW AND VERIFY. ALL DRGS,DIMENSION AND CONDITIONS, DISCREPANCIES. IN THE DRGS, OR IN BETWEEN THE DRGS AND ACTUAL. FIELD CONDITIONS SHALL BE REPORTED TO THE ARCHITECTS BEFORE STARING CONSTRUCTION. * THE ARCHITECTS SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR/ SUB CONTRACTOR COMPLIANCE WITH SAFETY AND REGULATION. *ANY AMBIGUITY FOUND, CONTACT ARCHITECT / INTERIOR DESIGNER BEFORE EXECUTION. * DWGS. ARE PROPERTY OF "STUDIO 919 ARCHITECTS"& SHALL NOT BE COPY WITHOUT PERMISSION SBI-JASDAN 01 NTS SHAILESH DEVDATT Architect Interior Designer DEVDATT PANDYA SHAILY SHUKLA PANDYA STUDIO 919 2nd Flr. - 8, AJITNATH SOC., Nr. PALDI P.O., AHMEDABAD , INDIA. TELEFAX: , 919studio@gmail.com
TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS.
BILL OF QUANTITIES FOR AIR CONDITIONING WORKS S.N. DESCRIPTION QTY UNIT VENTILATION & AIR CONDITIONING A HIGH SIDE WORKS (SUPPLY OF EQUIPMENTS) 1 DX TYPE SPLIT AIR-CONDITIONERS: Supply of Aircooled Split
More informationSBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21
SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21 PART B : PRICE BID TENDER FOR: PROPOSED AIR CONDITION WORKS OF SHIFTING
More informationSBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID
For the work of : SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL INVITES TENDERS ON BEHALF OF SBI, A.O.,INDORE THROUGH E-TENDERING PROCESS. PROPOSED AIRCONDITIONING WORKS OF SBI M.G.ROAD
More informationSBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.
SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD. (A Wholly Owned Subsidiary of SBI) CIRCLE OFFICE: 4TH FLOOR, SBI LOCAL HEAD OFFICE III/1-PANDIT J N MARG, KHARAVELA NAGAR BHUBANESWAR, ODISHA-751001 Part-II PRICE
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationIndian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.
Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi -110003, Ph. No. 011-49854100 TENDER NOTICE Sealed tender in two separate bids a) Technical bids,
More informationWater Chiller Solutions. A solution to every water cooling need.
Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,
More informationTENDER DOCUMENT FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING SYSTEM FOR NEW SERVER ROOM AT TAKSHASHILA BUILDING
TENDER DOCUMENT FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING SYSTEM FOR NEW SERVER ROOM AT TAKSHASHILA BUILDING Tender No: IIT/CIC/NEW-SERVER-ROOM/AC/2017-18/26, Dated: 05.10.2017
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationVOLUME 2 (BOQ & Price Bid)
TENDER DOCUMENT NIT No: PAT/CON/721/01 FOR Tender for Supply, Erection & Commissioning of Refrigeration Plant for chilled water system for Ice-Cream mix section complete for 20 KLPD Ice Cream Plant at
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationTOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING
ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND SR. Description QTY UNIT GROUP A AIRCONDITIONING 1 Supplying and erecting split type room Airconditioning unit 1.5 TR 3/5 star capacity 230/250V,
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationTENDER NOTICE. Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur
TENDER NOTICE Sealed Tender offers are invited for supply, installation & commissioning of Fire Hydrant System at our Gokul Dairy Project Complex at Gokul Shirgaon Kolhapur. Only contractors having valid
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationBOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E
A 1 2 4 PUMP HOUSE: BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E Supply, erection,testing & commissioning of Single stage, end suction / back pull-out type motor driven Jockey Pump of capacity 10.8
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationDUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 119/IWD/ED/644 SCHEDULE OF QUANTITY Name of work: Electrical work for: Part-A: Rewinding, overhauling and repairing of ceiling fan and exhaust fan installed
More informationSCHEDULE FOR AIR CONDITIONING WORK FOR NAC BUILDING FIRST FLOOR.
A) AIR-CONDITIONING SYSTEM 1.0 Air Cooled Ductle Split Ac Supply of INVERTER split type Hi-sttic Ductle unit nd ir cooled outdoor condensing units with Inverter scroll compressor, condenser fn,outer csing
More informationLONG LINE SET APPLICATION R-410A
LONG LINE SET APPLICATION R-410A TECHNICAL PUBLICATION TP-107K Goodman Company, L.P. INDEX SECTION 1. General Requirements for All Long Line Set Applications... 2 SECTION 2. Outdoor Unit and Indoor Unit
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationSECTION FAN COIL UNITS
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationMission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems
Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint
More informationAnnexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units)
Rayat Shikshan Sanstha s Karmaveer Bhaurao Patil Mahavidyalaya, Pandharpur, Dist-Solapur - 4133304 Ph : 02186-223104 TENDER FORM Email : kbppandharpur@gmail.com Date : 12-08-2017 A] General Information:
More informationDSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data
DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal
More informationVRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationHigh-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series
High-performance Packaged & Ductable Split Units: Aero, Thermo & Tropico Series NEW UNIQUE LCD CONTROLLER THE VOLTAS INTELLISYS RANGE Aero, Thermo and Tropico Series are High-performance Packaged & Ductable
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationSECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified
More informationSBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) INVITES RATE CONTRACT TENDER FOR
NIT NO 68 /18 Date 19.06.2018 SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) INVITES RATE CONTRACT TENDER FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF HIGH WALL SPLIT,
More informationSECTION WATER-SOURCE UNITARY HEAT PUMPS
SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationCONTENTS. B. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationTECHNICAL SPECIFICATION
TENDER DOCUMENT NIT No.: DLI/C&E/WI-675/290 FOR Tender for Design, Engineering, Supply, installation, testing and commissioning of PACKAGE AIR CONDITIONING (PAC) SYSTEM AND ASSOCIATED WORKS for the project
More informationDESIGN GUIDELINES SECTION HVAC
3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume
More informationNairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES
Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING ILLS OF QUANTITIES 26/10/2015 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR SERVER ROOM The air conditioning
More informationUnit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD
RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationPART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM
1 PACKAGE AIR CONDITIONER UNITS 1.1 Monthly PM of Flame Proof for Analyzer House Air Conditioner Units at various locations.job includes but not limited to attending all complaints & rectifying the problems,
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationSECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM
PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector
More information1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT
A MAIN PANEL/DB 1 Supply and Installation of main LT panel, floor mounted, front operated dead back, totally enclosed vermin proof, indoor, non drawout, cubicle type power dist. panel fabricated out of
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationset 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)
1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto
More informationSUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:
M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI
FIRE PROTECTION 1 G.I.PIPES Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 3589 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationSECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS
SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationSUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.
i 1 a SPRINKLER SYSTEM M S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports malleable srewed specials such as M S Reducers,Tees, elbows, flanges. Including cutting,
More information2. CURRICULUM. Sl. No.
. CURRICULUM Sl. No. Code Title No. of Lecture Hours 1 RAC 001 Fundamentals of Refrigeration and Air 60 conditioning RAC 00 Psychrometry, Heat load Estimation for 70 Air conditioning and Refrigeration
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationYour Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED
Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5
More informationSupply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder
Software Technology Parks of India - Pune (An Autonomous Society under Govt. of India, Ministry of Communications & Information Technology, Department of Electronics and Information Technology), Plot no.p-1,
More informationSECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.
1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationWATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP
EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSubmittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:
Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationDuctable Range of Air Conditioners
Ductable Range of Air Conditioners The world is witnessing growth at a breakneck speed. The upsurge in economic and social activities has led to rampant use of natural resources like water, minerals, energy,
More informationMAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.
Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600
More informationINSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................
More informationDARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES
SECTION 15830 HEATING & COOLING TERMINAL UNITS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All fan coil units shall be sized to meet design load while operating at medium speed. In extreme noise sensitive
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationC. Samples for Initial Selection: For units with factory-applied color finishes.
SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationtechnical data Fan coil unit FWB small duct unit
technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationSUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for
SUBMITTAL DATA for STOCK ROOFTOP UNIT AS ORDERED - PLEASE CHECK AND SIGN AS APPROVED Prepared for Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV 6301 Customer PO#: 38 Prepared by Mason and
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.
SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR
SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationLiebert CSU3000 Chiller
CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,
More information