Paddle Flow Switch. Pressure Control Flow Switch
|
|
- Anthony Chandler
- 5 years ago
- Views:
Transcription
1 Paddle Flow Switch GE-311 Plastic Paddle Flow Switch GE-312 Plastic Flow Switch GE-313 PETF Plastic Flow Switch GE-314 Stainless Steel Flow Switch GE-315 Adjustable Flow Switch GE-316 Brass Paddle Flow Switch GE-317 Brass Flow Switch GE-318 Explosion-Proof Flow Switch Pressure Control Flow Switch GE-511 Adjustable Pressure Control Flow GE-512 Differential Pressure Flow Switch GE-518 Pressure Control Flow Switch GE-519 Plastic Pressure Control Flow GE-921 Air Pressure Control Flow Switch GE-920 Air Pressure Control sensor
2 GE-311 Small Size Plastic Paddle Flow Switch * Protection Grade IP65 * Media Temperature -20~93 * Output 10A; 125/250V AC * Max Static Pressure 10 Bar *Metering Substances Gas, Water, Oil * Install Position Horizontal or Vertica * Pipe Size DN15, DN20, DN25 *Output: 1A(Max) 250VAC/DC 50W(Max) This products is produced by plastic material, used in Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability.
3 GE-312 A.YITE GROUP Plastic Flow Switch GE312 Used in the Water Heating Systerm, Welding Equipment, Laser Systerm, instruments and meters, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability. * Protection Grade IP65 * Media Temperature -20~93 * Output 10A; 125/250V AC * Max Static Pressure 10 Bar * Metering Substances Gas, Water, Oil * Install Position Horizontal or Vertical * Pipe Size DN15, DN20, DN25 * Output: 1A(Max) 250VAC/DC 50W(Max) When the flow is 1.8L/min ~~ 2.1L/min, the flow switch is Close When the flow is lower than 1.6L/min, the flow switch is Open.
4 GE-313 PETF Plastic Flow Switch This products is produced by plastic material with a long paddle, suitable for big pipe, used in SPA Appliance, Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. Teflon PETF Plastic Material High Performance in Chemical and Corrosion Environment Special Useful in SPA and Sea Water Appliance Technology Data: * Protection Grade IP65 * Media Temperature -10~100 Cd * Max Static Pressure 10 Bar *Metering Substances Gas, Water, Oil *Output: SPST BMF Magnetic Switch * Max Voltage 3A(50VA) * Max Current 250VAC/DC 50W(Max) Character: * No Pressure Loss * Proven paddle type in compact design, especially for serial applications. * Glass-fibre reinforced plastic ensures high stability * With pipe section or for push-in installation into manifolds of customer fittings * Long-term stable switching point, retreatment of paddle by magnetic force, no spring fatigue * Low Pressure Drop & Anti Corrosion environment to control flow, e.g. Swimmin Poll Heating Pump, Sea Water Pump, Central Heating Water Systerm
5 GE-314 A.YITE GROUP Stainless Steel Flow Switch 1. Media Temperature : -30~125 C 2. Pressure Loss: 0.01bar at Qmax. 3.Hysteresis depending on switch value, 4.Metering Substances Oil, Water, Gas, Air 5.Max Pressure: 30bar (100bar available) 6.Protection Class: IP65 7.Install Position: Horizontal or Vertical 8. Pipe Size: DN15, DN20, DN25 9. Materials: Stainless Steel Minimum Flow Set Point: 8 Liter per Hour. The body of GE-314 flow switch is Stainless Steel material, used in the Petrochemical Industry, Sewage Treatment, Welding Equipment, Laser Systerm, to measure or control the flow rate. A permanent magnet is installed in the GE-314, it is a high performance permanent magnet. The permanent magnet could control the BMF, the BMF is sealed in the top of GE-314. This switch is stability and precise with simple structure.
6 GE-315 Target Flow Switch The GE-315 Series Target Water Flow Switch is a new type flow switch, avoilding rust and bad contact by separating the electricity from the liquid. This products totally give up the isolating part for water and electricity by corrugated pipe applied on common target flow switch. When the micro switch is operating, it won t touch with low temperature metal part, so no condensation water, no rust and bad contact, and the Protection Grade up to IP65, it could be applied in corrosive air environment. Adjustable Flow Set Point Character: * Good Repeatability * Low Pressure Loss * Dirt Resistant * Hermetic Separation of Electrical and Hydraulic Components * Easy Adjustment of Switch * Tolerance ±15% of full scal * Media Temperature -30~110C * Average Pressure Loss 0.01bar at Qmax. * Hysteresis depending on switch value * Metering Substances Oil, Water, Gas, Air * Max Pressure 25bar (40bar available) * Protection Grade IP65 * Materials UPVC, Brass or Stainless Steel
7 GE-316 A.YITE GROUP Brass Paddle Flow Switch GE-316 Paddle Flow Switch is specially designed for the Flow Monitoring of Water Source, Water-Loop Heat Pump Air Conditioning Systems and Heat Pump Water Heater. Instruments operate by a spring-supported paddel with magnetic triggering of a reed switch. * Tolerance ±15% of full scal * Media Temperature -30~110 C * Average Pressure Loss 0.01bar at Qmax. * Hysteresis depending on switch value * Metering Substances Oil, Water, Gas, Air * Max Pressure 25bar (40bar available) * Pipe Size DN10~DN80 * Materials Brass or Stainless Steel Character: * Good repeatability * Low pressure loss * Dirt resistant * Hermetic separation of electrical and hydraulic components * Stress free fixation of switch unit by plastic cap
8 GE-317 Brass Flow Switch The body of GE-317 flow switch is Brass material, used in Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability. Special Useful In Water Heating Systerm 1. Media Temperature -20~85 C 2. Average Pressure Loss 0.01bar at Qmax. 3. Max Pressure 1.6M Pa 4. Flow Rate:1.5~30 L/Min 5. Output: 1A(Max) 250VAC/DC 100W(Max) 6. Protection Class IP65 7. Install Position Horizontal or Vertical(The Wire must be top) 8. Materials Brass GE-318 Explosion-Proof Flow Switch 1. Max Pressure: 100Bar 2. Work Temperature: -20~120 C 3. Pipe Size: DN8~DN25 4. Voltage: 5-24V/200mA(AC/DC); 250V/120mA(AC/DC) 5. Material: Stainless Steel
9 Differential Pressure Control Flow Switch The Differential Pressure Switch is a new type flow switch, when the water flow (differential pressure) in system rises up or falls down to one set value, it will output a warning or sent switch-off signal to automatic control system. And it could also be used to indicate the status of pump or water filter. Accurately Control & Stability No Pressure Loss * Dirt Resistant * Easy Install It could avoid the shortcomings of annual inspection or changing target flow switch for water chiller unit so it could be applied widely in the water protection, status feedback of pump and by-pass control of differential pressure in evaporator and condenser in medium and large sized water chiller unit.
10 A.YITE GROUP * Protection Grade IP54 * Media Temperature -20~93 C * Environmental Temperature -20~71 C * Max Voltage 250V AC * Max Current 3A * Max Static Pressure 10/16/20 Bar * Metering Substances Oil, Water, Air * Max Pressure 25bar (30bar Available) * Main Materials Brass or Stainless Steel GE-511 Differential Pressure Flow Switch with Adjustable Set Point GE-511A Series is D-P Flow Switch with single adjustable setpoint. The adjustable differential pressure switch could be calibrated directly by manufacturer according to customer s requirement, and printed the calibrated value on the label of product, so user needs not readjust in the field. The customer could calibrate by professional instrument according to the differential pressure required by equipment, and A.YITE COMPANY could provide relevant service. Type Pressure Setpoint Switching Differential Range Set To Output GE-511A030 5~30k Pa 3k Pa 1 3A SPDT GE-511A070 6~70k Pa 5k Pa 1 3A SPDT GE-511A100 6~100k Pa 6k Pa 1 3A SPDT GE-511A200 10~200k Pa 10k Pa 1 3A SPDT GE-511A300 20~300k Pa 15k Pa 1 3A SPDT GE-511B Series is D-P Flow Switch with 2 adjustable setpoint. In order to meet various requirements of customers, A.YITE COMPANY also developed the adjustable double setpoints DP switch for upper-lower limit control of differential pressure. And if choose the local indicator, it could be applied to control the water cooled evaporator and condenser in HVAC system, the more or less flow of other heat exchanger, and low flow of heat exchanger due to scaling or dirty jamming, which has incomparable advantages than target flow switch. Type Pressure Setpoint Range Switching Differential P1 P2 Set To P1 Set to P2 Output GE-511B030 5~30k Pa 6~100k Pa 3 k Pa 6 k Pa 2 3A SPDT GE-511B070 6~70k Pa 6~100k Pa 5 k Pa 6 k Pa 2 3A SPDT GE-511B100 6~100k Pa 6~100k Pa 6 k Pa 6 k Pa 2 3A SPDT GE-511B150 6~100k Pa 10~200k Pa 6 k Pa 10 k Pa 2 3A SPDT GE-511B200 10~200k Pa 10~200k Pa 10 k Pa 10 k Pa 2 3A SPDT GE-511B300 20~300k Pa 20~300k Pa 15 k Pa 15 k Pa 2 3A SPDT
11 * Stable * Accuracy Control * No Pressure Loss * Dirt Resistant * Easy Adjustment of Switch * Easy Install A.YITE GROUP Monitor The Working Condition of Pump * Protection Grade IP54 * Medium Temperature -20~93 C * Environmental Temperature -20~71 C * Output: 10A; 125/250V AC * Metering Substances Oil, Water, Air * Max Pressure 25bar (30bar Available) * Main Materials Brass l * Cable 1.5m, 2 0.5mm2 GE-512 Differential Pressure Flow Switch With Fixed Pressure Set Point GE-512 Series is Differential Pressure Switch with Fixed Pressure Setpoint, the setpoint could not be changed. So if the user choose one type of GE-512, the user could not change the flow setpoint, then it will avoid the mistake in Installing.
12 Type Pressure Setpoint Swithing Differential Set To Output Cable GE K Pa 1.5 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 2 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 3 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 4 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 5 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 6 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 7 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 8 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 8 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 GE K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 New Products * Protection Grade IP54 * Medium Temperature -20~93 C * Environmental Temperature -20~71 C * Output: SPST 5A(Max) 125/250V AC * Metering Substances Oil, Water * Max Pressure 20bar (30bar Available) * Main Materials Brass l * Cable 1.5m, 2 0.5mm2 GE-518 Differential Pressure Control Flow Switch
13 * Easy Install * Sensitive * Dirt Resistant * No Pressure Loss * Connect with female thread * Fixed Pressure Setpoint, the setpoint could not be changed New Products * Medium Temperature: -20~93 C * Diaphragm: EPDM * Max Static Pressure: 10 bar * Output: 10A 250VAC SPDT switch * Metering Substances Oil, Water, Sea water * Main Materials Plastic GE-519 Plastic Pressure Control Flow Switch It is a plastic body, as a differential pressure switch, used in water heating systerm. It is a better Substitute Products for common target flow switch, as it is stable performance and low price.
14 GE921 Air Differential Pressure Switch Series of GE921 Air Differential Pressure Switch can be used to sense (differential) pressure and flow of air in ducts and pipes. Technical * Max. differential pressure: 5000Pa * Protection Class: IP54 * Output: 1.0A (0.4A)/ 250VAC * Working temperature:-20~85 C * Storage temperature: -40~85C * Min. Actuating pressure: 20Pa(Standard); * min.starting interval: 10Pa; range: 20~30Pa * Installation Direction: vertical (standard installation style) * Hose connection: pipe P6.2mm Type Adjust Range Return Difference Deviation GE921A 20~200 Pa 10 Pa ± 10% GE921B 40~100 Pa 20 Pa ± 10% GE921C 40~200 Pa 20 Pa ± 10% GE921D 50~500 Pa 20 Pa ± 10% GE921E 200~1000 Pa 100 Pa ± 10% GE921F 500~2500 Pa 150 Pa ± 10% GE921G 1000~54000 Pa 200 Pa ± 10% Possible fields of application include: * Monitoring air filters and ventilators * Monitoring industrial cooling-air circuits * Maximum air flow controller for variable air volume systems * Overheating protection for fan heaters * Monitoring flows in ventilation ducts * Controlling air and fire-protection flaps * Frost protection for heat exchangers * Air proving in ventilation ducts
15 GE920 Air Differential Pressure Transmitter GE920 Differential Pressure Transmitter is Adopting diffused silicon chip measuring technology, with double seal pressure piping and exact differential pressure measuring. It is suitable for differential pressure measuring for medical treatment, chemical fiber, electricity, dustless house and etc. Ranges: 0~50Pa~200Pa~1KPa~10KPa ~100KPa ±(50Pa~200Pa~1KPa~10KPa ~100KPa) Accuracy:0.1%, 0.5%FS, 1.0%FS Output: 0~5V; 1~5V; 4~20mA Power supply:12vdc~36vdc(24vdc is Standard) Medium Temperature: -20~85 C Typical applications include: Filter obstructive alarm. Maximum air flow controller for variable air volume systems. Air proving in ventilation ducts. Burner air control Overheating protection for Electric Heater with Blower
A.YITE GROUP (Hongkong & Shanghai)
In this page, you will find common paddle flow switch, differential pressure flow switch, thermal flow switch, Flow Sensor Paddle Flow Switch FS-01 FDA Flow Switch G1/4 GE-311 Plastic Paddle Flow Switch
More informationA.YITE GROUP (Hongkong & Shanghai)
In this page, you will find common paddle flow switch, differential pressure flow switch, thermal flow switch, Flow Sensor Paddle Flow Switch FS-01 FDA Flow Switch G1/4 GE-311 Plastic Paddle Flow Switch
More informationFlow Switches. Series VHS, VKS, VH
Flow Switches Series VHS, VKS, VH Reliable - Safe - Proven! Our tried-and-tested fl ow monitoring switches for liquids are used for two basic purposes: To ensure a minimum fl ow rate, e.g. of cooling water
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationStatic differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa
Static differential pressure measuring instruments Pascal-ST/Z for low measurement ranges 0... +50 Pa oder 0... +200 Pa NOVASINA 2008 Agenda AGENDA Pascal-ST/Z series Measurement principle Highlights Technical
More informationINSTRUMENTATION AND CONTROL DEVICES FOR HVAC
PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE
More informationAccuracy by Design Products for the HVAC Professional
Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation
More informationproduct overview ProControl
product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.
More informationNEXT PRESSURE GENERATION EXPANSION OF FIRST SENSOR S PRODUCT FAMILIES
NEXT PRESSURE GENERATION EXPANSION OF FIRST SENSOR S PRODUCT FAMILIES FRAMEWORK CONDITIONS Continual growth of MEMS pressure sensor market MEMS and sensors revenue market in B$ Source: Status of the MEMS
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationVariable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235
Data Sheet (US) Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235 Easily Cleaned - Disassembly is simplified by O-ring construction MODEL 10A2235A-OA Virtually
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More information1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W
594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free
More informationFlow switch. Operating Manual. English manual page Page 1 of 15 Fax:
Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...
More informationWallace & Tiernan Gas Feed Systems V2000 Chlorinator
Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators
More informationTemperature controllers TW, TO and TP, Speedy Therm
Temperature controllers TW, TO and TP, Speedy Therm English Compact dimensions, stainless steel tanks, internal reservoirs and couplings, high capacity peripheral pumps and electronic control board unify
More informationQD6310. Fixed Gas Detector Operation Manual
QD6310 Fixed Gas Detector Operation Manual Safety Information Before using the device, please first carefully read and follow the following information to operate the device: Please don't use the defective
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More informationTA-Compact-P. Giving you MORE by giving you LESS
TA-Compact-P Giving you MORE by giving you LESS control valve balancing valve 5 in 1 full measurement TA-Compact-P The new two-way pressure independent balancing and control valve for terminal units in
More informationMEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors
MEMS Accelerometer ICs AMR Magnetic Sensor ICs Gas Flow Modules Differential Pressure Sensors Tilt Modules Current Sensors MEMSIC s unique thermal technology uses heated gas molecules to detect acceleration
More informationIS Series Pressure Sensing Switches
IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression
More information1592P01. for liquids in piping DN
1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type
More informationMetal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)
MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand
More informationOEM Sensors for HVAC manufacturers Pool water
OEM Sensors for HVAC manufacturers Pool water 2 Pool water Typical flow switch application Product features Pump monitoring For pool heaters or water disinfection Protection against overheating, dry-running
More informationModels TX-KE and TX-KP Toxic Gas Transmitters
Models TX-KE and TX-KP Toxic Gas Transmitters Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Dr. Lake Zurich, IL. 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com
More informationElectronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationOEM Sensors for HVAC manufacturers Heat recovery Chiller
OEM Sensors for HVAC manufacturers Heat recovery Chiller 2 Heat recovery / Chiller Typical magnetic-inductive flow sensor application Product features For determining the energy balance Measurement signal
More informationElectronic Pressure Digest. Pressure and Temperature Transmitters
Electronic Pressure Digest Electronic Pressure Digest Pressure and Temperature Transmitters R General Purpose Pressure Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed
More informationRefrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.
Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationPREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE
PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel
More information号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd
川制 00000425号 PRODUCTORS CATALOGUE ChengDu SAND Electronic Co. Ltd Chinese largest pressure measuring instruments manufacturer 1) Us factory/manufacturer was established in 1992 2) Specialized in manufacturing
More informationSensors and Switches in Commercial Traction Elevators
Sensors and Switches in Commercial Traction Elevators An Application Note Background People-moving, cable-pull elevators are classified as commercial (see Figure 1) or residential, and have different codes
More informationQVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.
Document No. 55-7 September 0, 0 QVE90U Flow Switch Description Flow switch for liquids in piping 3/4-inch to 8-inch (0 mm to 00 mm) diameter Features Application Product Number Contact load/switching
More informationSensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2
Sensors and switches Temperature, Pressure, Humidity, Air flow, CO 2, CO and NO 2 Regin sensors and switches Comfortable and economic indoor climate To measure is to know. Temperature, carbon dioxide,
More informationModus Model DA General Eastern Low Differential Pressure Alarm Controller
GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines
More informationRH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description
RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy
More informationDesign-Edition. Design-Edition Thermostatic valves and lockshields, sets
Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime
More informationApplication Alley. Utility Meters - Reed Sensor. Utility Meters Use Reed Sensors To Measure Water Flow, Gas and Electricity PARTNER SOLVE DELIVER
PARTNER SOLVE DELIVER Utility Meters - Reed Sensor Introduction Contacts dynamically tested Most households and businesses have meters reading and recording the volume of water used, the volume of gas
More informationCapital Controls SERIES 70CV3000 CHLOROMATIC VALVE
Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Integrated Gas Control Valve with Integral Controller The Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is designed to control chemical
More informationVacuum Systems. A complete line of vacuum pumps and accessories for every dairy
Vacuum Systems A complete line of vacuum pumps and accessories for every dairy 2 GEA VACUUM SYSTEMS CL Vacuum Pump Exclusive coated lobes increase efficiency Commercial grade lobe style vacuum pump designed
More information2-wire Passive Intelligent Loop (LED) Display Meter
Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter
More informationDuct and Rough Service Carbon Monoxide Sensor
Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.
More informationProRadiant Controls, Valves and Actuators
214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation
More informationProduct Training Module: Digital Pressure Sensors with CANopen Model DPS
Product Training Module: Model DPS Copyright 2012 Honeywell International Inc. All rights reserved. Summary Of Content In this training module, you will learn the following about Honeywell s Model DPS
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationAir Check EX LEL Gas Monitor Instruction Manual
Air Check EX LEL Gas Monitor Instruction Manual PureAire Monitoring Systems, Inc. 1140 Ensell Road Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com
More informationFSW300 Series Flow Switch
. FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of
More informationKOBOLD PSR/PS FLOW SWITCH
KOBOLD PSR/PS FLOW SWITCH User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-PSR-PS_8-10 PSR/PS Table
More informationType 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats
Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats
More information2-wire Passive Intelligent Loop (LED) Display Meter
Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter
More informationEN - english. Instructions for installation and operation. Mobile humidity meter DP 207
EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please
More information.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.
Issued 2006/08/01 Section 15751 Humidifiers Page 1 of 7 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section 01810 Commissioning..4 Section
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More informationSELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses
SELECTION GUIDE SELECTION GUIDE Pressure, Flow & Liquid Level Products for Aerospace & Military Uses P R E C I S I O N S E N S O R S Altitude Switches PRECISION SENSORS 50 Seemans Lane Milford, CT 06460
More informationGuide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS
SECTION 230923.14 FLOW INSTRUMENTS Data contained in this guide specification may be placed in either of the following sections, depending on the specifics of the system design, or incorporated within
More informationThe Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni
OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted
More informationINSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS
THERMAL INSTRUMENT Co. 217 Sterner Mill Road, Trevose, PA 19053 Telephone No. (215) 355-8400 Fax No. (215) 355-1789 Email: office@thermalinstrument.com INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES
More informationPressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches
CATALOG No. 3150 MODEL No. AdC No. AdS Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches AdC-Type Pressure Gauges with Contact AdC-WType Differential Pressure
More information1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.
AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationWallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch
Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Overview continues to be the leader in the chemical feed and disinfection of potable water, wastewater and industrial process applications.
More informationUsing the DewMaster Deluxe Dew Point/ Humidity Hygrometer
JAN 0 ::0 AM SERVOLOCK APPLICATION NOTE 0_0_ Rev Using the Deluxe Dew Point/ Humidity Hygrometer The Model is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously measure
More informationCHILLER. Operator s & Installation Manual
CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationFeatures and Benefits
NIRS Analyzer Pro NIRS Analyzer Pro is a process analysis system based on high-resolution diode array technology. It provides nondestructive analysis of granules, powders, slurries or opaque samples directly
More informationph Measuring System Start-up and maintenance manual e Contents
Contents 1. Starting up 1.1 Scope of delivery: 1.2 Reconditioning 1.3 Installing the ph probe 1.4 Installing the switch cabinet 1.5 Filling the electrolyte reservoir 1.6 Installing the reference electrode
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More information85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage
FEATURES Weldable and Threaded Process Fittings -40ºC to +125ºC Operating Temperature ±0.1% Pressure Non Linearity Solid State Reliability APPLICATIONS Medical Instruments Process Control Fresh & Waste
More informationNQ Series Portable Chillers
NQ Series Portable Chillers Electrical Components Mounted and Wired All electrical components and sensors are mounted, wired, and fully tested at the factory to reduce installation time and ensure the
More informationHand Held Welding Guns
Type Rion handheld device to weld thermoplastic materials for roofers, flooring tilers, membrane processors, synthetic material processors, etc. handy, building site-proved stepless adjustments temperature
More information1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.
Page 230519-1 SECTION 230519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationHygro and hygrothermo transducers (capacitive) for HVAC monitoring
Data Sheet 90.7021 Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special
More informationaquaconcept Cold water
aquaconcept Cold water Applications The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration
More informationUsing the DewTrak II Dew Point/ Humidity Transmitter
APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationAzbil introduction 2015
Azbil introduction 2015 Overview Azbil introduction & company profile Product divisions Product overview Magnetic flow meter (MTG) Magnetic flow meter (MGG) Thermal mass flow meters Pressure transmitter
More informationCALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.
Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid
More informationFlush individual room control for floor heating systems
Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control
More informationIndustrial cooling systems LT
Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in
More informationFill Point, Level Gauges, and Control Range
Fill Point, Level Gauges, and Control Range Page 1 Contents Fill Points, Level Gauges, and Control Equipment... 3 Fill Point Cabinets... 4 Single Tank Cabinet... 5 Twin Tank Cabinet... 6 Three Tank Cabinet...
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:
GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,
More information154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range FEATURES O-Ring Mount -20ºC to +85ºC Compensated Temperature
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump
Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution
More informationCAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS
CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS The Capital Controls Series WP70CV3 gas feeders are wall panel mounted and vacuum operated. Easy to install, each Series WP70CV3 wall panel feeder is factory
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationSAUTER Valveco compact. A pressure-independent multi-function valve
SAUTER Valveco compact A pressure-independent multi-function valve I take care of everything in one unit. Valveco compact combines a balancing valve, a control valve and a differential pressure controller.
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationOTC, OTM and OTI Series Options
OTC, OTM and OTI Series Options Audible Alarm w/silence (AA1)...2 Anti Drain-back Valve (AD1 or AD2)...2 Alarm Beacon (AV1)...2 Auto Water Make-up (AWM)...2 Balancing Valves...2 Uncontrolled DI Loop (D01)...2
More informationue short form catalog Leaders in Safety, Alarm & emergency Shutdown
ue short form catalog Leaders in Safety, Alarm & emergency Shutdown WirelessHART Gas Detector for Toxic & Combustible Gases Electronic and Electromechanical Switches for Vacuum, Pressure, Differential
More informationTemperature Solutions Line Card
Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,
More informationUsing the Model 1500 Portable Chilled Mirror Hygrometer
APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately
More informationBINDER Scientific Product Catalog
BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under
More informationTough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.
The Art of Measuring. Tough as They Come. Ceramat Retractable fittings for extreme conditions. With ceramic sealing to the process. Minimum wear Low operating costs Maximum availability The Solution: Ceramat
More information