2012 UPC STANDARDS TASK GROUP

Size: px
Start display at page:

Download "2012 UPC STANDARDS TASK GROUP"

Transcription

1 2012 UPC STANDARDS TASK GROUP The scope of this task group is to review standard cross-references within the body of the 2009 Uniform Plumbing Code and Table The objective is to update standards listed in Table 14-1 with the current published printing. The recommended proposed code changes were placed in the monograph based on numerical order along with the item number as shown next to the proposal. Item #1 - Revise text as follows: (Monograph Item #228) CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 CHAPTER 14 REFERENCED STANDARDS General Standards. The standards listed in Table are intended for use in the design, testing, and installation of materials, devices, appliances and equipment regulated by this code. Standards for Materials, Equipment, Joints and Connections. Where more than one standard has been listed for the same material or method, the relevant portions of all such standards shall apply. TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION REFERENCED SECTIONS AHAM DW * Household Electric Dishwashers 401.1, 401.3, 404.4, , AHAM FWD Food Waste Disposers 401.1, 404.4, APSP * Public Swimming Pools Swimming USPSHTC Pools, and Spas, and Hot Tubs ASCE * Earthquake-Actuated Automatic Gas Shutoff Devices ASHRAE * Energy Standard for Buildings Except Low-Rise Residential Buildings ASME A * Scheme for the Identification of Piping Systems Piping ASME A * ASME A (R2005)* ASME A * Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-Connected Receptors) Air Gap Fittings for Use with Plumbing Fixtures,, and Appurtenances Performance Standard and Installation Procedures for Stainless Steel Drainage Systems for Sanitary DWV, Storm, and Vacuum Chemical Applications, Above- and Below Ground (Note 1) Macerating Toilet Systems and Related Fittings Table 6-2, Table 6-3, 603.1, Fittings Table 6-2, Table 6-3, 603.1, 801.1, 806.0, Piping, Table 7-1, 701.1, 701.2, 707.1, ASME A (R2004)* Fixtures ASME A (R2002)*2009 Water Heater Relief Valve Drain Tubes ASME A * Water Closet Personal Hygiene Devices Fixtures ASME A Plastic Fittings for Connecting Water Closets to Fittings (R2004)* the Sanitary Drainage System 1

2 ASME A Point of Use and Branch Water Submetering (R2008)* Systems (Discontinued) ASME A Manually Operated, Quarter-Turn Shutoff Valves for Use in Plumbing Systems Valves Valves, Metallic ball ASME A M-1997 Floor-Affixed Supports for Off-the-Floor Fixtures , (R2002) (R2008) Plumbing Fixtures for Public Use ASME A Framing-Affixed Supports for Off-the-Floor Fixtures , (R2004)* Water Closets with Concealed Tanks ASME A Floor and Trench Drains DWV (R2007)* ASME A Roof, Deck, and Balcony Drains DWV (R2008)* ASME A (R2007)* Enameled and Epoxy Coated Cast Iron and PVC Plastic Sanitary Floor Sinks Fixtures Table 4-1 footnote (9), ASME A * Siphonic Roof Drains DWV 301.2, ASME A Backwater Valves Valves (R2008)* ASME A (R2004)* Grease Interceptors Fixtures , , ASME A Grease Removal Devices Fixtures , (R2007)* ASME A * FOG (Fats, Oils, and Greases) Disposal Systems Fixtures ASME A /CSA B Plumbing Supply Fittings Fittings 418.0, , ASME A /CSA Plumbing Waste Fittings Fittings 404.3, 701.0, B ASME A (R2008)* , ASME A /CSA B * 2009 ASME A (R2004)* ASME A M-1994 (R2004)* ASME A /CSA B * ASME A * ASME A /CSA B * ASME A (R2004)* ASME A /CSA B * ASME A M-1994 (R2004)* Performance Requirements for Devices and Systems in Plumbing Fixtures Fittings Kitchen, Lavatory, Shampoo Bowls, and Shower Fittings with Flexible Hose Flexible Water Connectors Piping 604.4, , Deck Mounted Bath/Shower Transfer Valves with Integral Enameled Cast-Iron Plumbing Fixtures(Supplement ) Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures Vitreous China Plumbing Fixtures and Hydraulic Fixtures Requirements for Water Closets and Urinals Ceramic Plumbing Fixtures Stainless Steel Plumbing Fixtures (Designed for Residential Use) Porcelain-Enameled Formed Steel Plumbing Fixtures (Supplement ) (Replaced with ASME A /CSA B Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures) Valves , Fixtures 401.1, 402.1, 411.5, 411.6, 411.7, 413.0, 414.0, Fixtures 401.1, 402.1, 402.2, 402.3, 410.0, 410.1, 410.2, 410.3, 410.4, 410.5, Fixtures 401.1, 402.1, 402.2, 402.3, 411.5, 414.0, Fixtures 401.1, 411.5, 411.6, 411.7, ASME A * Trim for Water-Closet Bowls, Tanks, and Urinals Fixtures ASME A * Hydromassage Bathtub Fixtures 401.1, ASME A a * Suction Fittings for Use in Swimming Pools,Wading Pools, Spas and Hot Tubs Swimming Pools and Spas

3 ASME A M-1991 (R2002)* ASME A (R2008)* ASME A * ASME A (R2007)* ASME A * ASME A * Non-Vitreous Ceramic Plumbing Fixtures (Replaced with ASME A /CSA B Ceramic Plumbing Fixtures) Fixtures Dual Flush Devices for Water Closets Fixtures Wall Mounted, Pedestal Mounted, Adjustable, Elevating, Tilting, and Pivoting Lavatory, Sink, and Shampoo Bowl Carrier Systems and Drainage Waste Systems Electrohydraulic Water Closets Replaced with ASME A /CSA B Ceramic Plumbing Fixtures Six-Liter Water Closets Equipped with a Dual Flushing Device Bathtubs/Whirlpool Bathtubs with Pressure Sealed Doors Fixtures 401.1, Fixtures 401.1, Fixtures 401.1, Fixtures ASME A * Vitreous China Nonwater Urinals Fixtures 401.1, ASME A * (D) Qualification of Installers of High Purity Piping Certification Systems (Discontinued) ASME A * Qualification of Installers of Firestop Systems and Certification Devices for Piping Systems ASME A M-1985 Hydrants for Utility and Maintenance Use (Note Valves (R2007)* 1) ASME A M-1991 Cleanouts (Note 1) DWV 707.0, (R2002)* (R2008) ASME B (R2006)* Pipe Threads, General Purpose, Inch Joints , (A) ASME B (R2003)* Dryseal Pipe Threads, Inch Joints (R2008) ASME B * Gray Iron Pipe Flanges and Flanged Fittings: Classes 25, 125, and 250 Fittings 604.1, 604.5, , (5), ASME B * Malleable Iron Threaded Fittings: Classes 150 and Fittings 311.8, 604.1, 604.6, Table 6-4 Table 7-1, 701.2, , , (2) ASME B (R2006)* Gray Iron Threaded Fittings:,Classes 125 and 250 (Includes Revision Services) Fittings 311.8, 604.1, Table 6-4, 604.5, (2) ASME B * Pipe Flanges and Flanged Fittings: NPS 1/2 Fittings through NPS 24 Metric/Inch ASME B (R2006) 2009* Cast Iron Threaded Drainage Fittings (Note 1) Fittings 311.8, Table 7-1, ASME B * Cast Copper Threaded Fittings: Classes 125 and 250 Fittings 311.8, , Table 6-4, ASME B (R2005)* Cast Copper Solder Joint Pressure Fittings (Note 1) Fittings , Table 6-4, ASME B (R2004) Metallic Gaskets For Pipe Flanges: Ring-Joint, Joints * Spiral-Wound, And Jacketed ASME B * Nonmetallic Flat Gaskets for Pipe Flanges Joints ASME B (R2005)* Wrought Copper and Copper Solder Joint Pressure Fittings Fittings , Table 6-4, 604.1, ASME B (R2006)* Cast Copper Solder Joint Drainage Fittings: DWV Fittings , Table 7-1, 701.2, ASME B * Cast Copper Pipe Flanges and Flanged Fittings: Classes 150, 300, 400, 600, 900, 1500 and 2500 Fittings 604.1, , ASME B * ASME B * Cast Copper Fittings for Flared Copper Tubes Wrought Copper and Wrought Copper Solder- Joint Drainage Fittings DWV (Note 1) Fittings , Table 6-4, 604.1, Fittings , Table 7-1, 701.2,

4 ASME B (R2007)* Manually Operated Metallic Gas Valves for Uuse Valves , in Gas Piping Systems up to 125 psi (Sizes NPS 1/2 -NPS 24) ASME B * Valves-Flanged, Threaded, and Welding End Valves 301.0, ASME B (R2006) 2009* ASME B * ASME B * Malleable Iron Threaded Pipe Unions: (Classes150, 250 and 300) (Includes Revision Services) Manually Operated Thermoplastic Gas Shutoffs and Valves in Gas Distribution Systems Large Diameter Steel Flanges: NPS 26 through NPS 60 Metric/Inch Standard Wrought Copper and Copper Braze-Joint Pressure Fittings Fittings 301.0, , Valves , Fittings 301.0, (5) ASME B * Fittings 301.0, (R2008) ASME B31.1b * Power Piping Piping ASME B * Process Piping Piping Appendix F ASME B36.10M-2004* Welded and Seamless Wrought Steel Pipe Piping, ASME B36.19M-2004* Stainless Steel Pipe Piping, 301.0, 301.2, Table 6-4 ASME BPVC Section IV- 2007* Rules for Construction of Heating Boilers 301.0, 301.2, Table 12-1 ASME BPVC Section VIII- Rules for Construction of Pressure Vessels (2), * Division 1 ASME BPVC Section IX- Welding and Brazing Qualifications Certification , * ASSE * Atmospheric Type Vacuum Breakers , , , , , , ASSE * Anti-Siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks 410.1, Table 6-2, 603.1, ASSE * 2009 Water Pressure Reducing Valves for Domestic Valves 608.2, Waster Distribution Systems ASSE * Prevention Requirements for Commercial Dishwashing Machines , , ASSE * 1989R Residential Use Dishwashers (Inactive) , , ASSE * Home Laundry Equipment (Inactive) , ASSE * Plumbing Aspects of Residential Food Waste Disposer Units , , ASSE * Commercial Food Waste Grinder Units (Inactive) , ASSE * Water Hammer Arresters, , Water Supply Component ASSE * Hose Connection Vacuum Breakers 603.1, ASSE * Preventer with an Intermediate Atmospheric Vent ASSE * Reduced Pressure Principle Preventers and Reduced Pressure Principle Fire Principle Preventers , , , , , , , , , ASSE * Prevention Devices for Hand Held ASSE * Showers Double Check Prevention Assemblies and Double Check Fire Prevention Assemblies , ,

5 ASSE * Automatic Compensating Valves for Individual Valves Showers and Tub/Shower Combinations ASSE * 2009* Temperature Actuated Mixing Valves for Hot Valves Water Distribution Systems ASSE * Trap Seal Primer Valves-Potable Water Supplied Valves ASSE * Vacuum Breaker Wall Hydrants, Freeze Resistant Table 6-2, Automatic Draining Type ASSE * Pressure Vacuum Breaker Assembly Table 6-2, , , , , , ASSE Drains Air Gaps for Domestic Dishwasher Applications ASSE * Preventer for Beverage Dispensing Table 6-2, Equipment ASSE Hot Water Dispensers, Household Storage Type Electrical ASSE * Dual Check Valve Preventers ASSE Dual Check Valve Type Preventers for 603.1, Carbonated Beverage Dispensers, Post Mix Types ASSE * Laboratory Faucet Preventers ASSE Pressurized Flushing Devices (Flushometers) for 410.1, Plumbing Fixtures ASSE * Trap Seal Primer Devices-Drainage Types and DWV Electronic Design Types ASSE * Reduced Pressure Detector Fire Prevention Assemblies Table 6-2, , , , , ASSE * Double Check Detector Fire Prevention Assemblies ASSE * Hose Connection Preventers ASSE * Chemical Dispensing Systems ASSE * Spill Resistant Vacuum Breakers Table 6-2, ASSE * Outdoor Enclosures for Prevention Assemblies Fluid Conveying ASSE * Removable and Non-Removable Push-Fit Fittings Fittings ASSE * Temperature Actuated Flow Reduction (TAFR) Valves for Individual Fixture Fittings Valves ASSE Individual Pressure Balancing In-Line Valves for Individual Fixture Fittings (Note 6) Valves ASSE * Automatic Temperature Control Mixing Valves Valves Table 6-2, , , , ASSE * Water Temperature Limiting Devices Valves 413.1, 414.5, ASSE Dielectric Pipe Unions Joints 301.0, (3) ASSE Series * ASSE Series * Professional Qualification Standard for Prevention Assemblies, Testers, Repairers, and Surveyors Cross-Connection Control Professional Qualifications Professional Qualifications Standard for Medical Gas Systems Personnel Certification 603.1, Certification ,

6 ASTM A (R2004) (R2009) Ferritic Malleable Iron Castings Piping, ASTM A (R2008) Gray Iron Castings Piping, ASTM A Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Piping, Welded, and Seamless Table 6-4, 604.1, Table 7-1, (2) ASTM A Cast Iron Soil Pipe and Fittings (Note 1) Piping, ASTM A Seamless Carbon Steel Pipe for High- Temperature Service Piping, ASTM A Gray Iron Castings for Valves, Flanges, and Pipe Fittings Piping, ASTM A (R2006) Cupola Malleable Iron Piping, ASTM A (R2007) Copper-Brazed Steel Tubing Piping, ASTM A a 2008 Seamless and Welded Austenitic Stainless Steel Piping, Tubing for General Service ASTM A Seamless, Welded, and Heavily Cold Worked Pipes Piping, Austenitic Stainless Steel Pipes ASTM A (R2008) e1 Ductile-Iron Pressure Pipe Piping, ASTM A a 2009 Stainless Steel Bars and Shapes for Use in Boilers Piping, and Other Pressure Vessels ASTM A (R2003) Corrosion-Resistant High-Silicon Iron Castings Piping, (R2008) ASTM A (R2004) Ductile Iron Castings Piping, (R2009) ASTM A a Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Piping, Iron -Coated (Galvannealed) by the Hot-Dip Process ASTM A (R2009) e1 * Welded and Seamless Carbon Steel and Piping, Austenitic Stainless Steel Pipe Nipples ASTM A (R2008) High-Silicon Iron Pipe and Fittings (Note 1) Piping, Table 7-1, 701.1, 701.2, 807.3, 903.1, , , , , , Appendix E 301.0, Table 6-4, , Appendix F Table 6-4, , Appendix F 301.0, Appendix F 313.8, , , , ASTM A a 2009 Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications Piping, Table 7-1, 701.1, 701.2, 807.3, 903.1, , , , ASTM B * (R2009) Refined Lead Joints 313.8, , 401.2, 411.8, 701.3, , 906.6, ASTM B Solder Metal (Note 2) Joints , ASTM B e1 Seamless Copper Pipe, Standard Sizes Piping, Copper Table 6-4, 604.1, , ASTM B (R2004) 2009 Seamless Red Brass Pipe, Standard Sizes Piping, Copper Table 6-4, 604.1, Table 7-1, 701.1, , ,

7 ASTM B Seamless Copper Tube Piping, Copper ASTM B Seamless Copper Water Tube Piping, Copper ASTM B a Seamless Brass Tube (Metric) Piping, Copper ASTM B a 2009 Copper Sheet, Strip, Plate, and Rolled Bar ASTM B ASTM B ASTM B ASTM B e1 Copper Bar, Bus Bar, Rod, and Shapes and General Purpose Rod, Bar, and Shapes Aluminum and Aluminum- Drawn Seamless Tubes Aluminum and Aluminum- Seamless Pipe and Seamless Extruded Tube General Requirements for Wrought Seamless Copper and Copper- Tube Piping, Piping, Piping, Copper ASTM B Seamless Copper Tube for Air Conditioning and Refrigeration Field Service Piping, Copper ASTM B Threadless Copper Pipe, Standard Sizes Piping, Copper ASTM B Copper Drainage Tube (DWV) Piping, Copper Table 6-4, 604.1, Table 7-1, 701.1, , , Table 6-4, 604.1, , , , , , , Appendix E 301.2, Table 64, ASTM B Copper Sheet and Strip for Building Construction ASTM B Welded Copper Tube Piping, Copper ASTM B a Copper Sand Castings for General Piping, Copper Applications (Note 3) ASTM B Welded Brass Tube Piping, Copper ASTM B (R2005) e1 ASTM B e1 (R2009) Brass, Copper, and Chromium-Plated Pipe Nipples Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Tube Piping, Copper , Table 6-4, 604.1, Table 7-1, 701.1, , , , , Appendix E Table 6-4, 604.1, Table 7-1, Table 7-1, 701.1, , Table 6-4, , , Joints ASTM B (R2006) Seamless Copper Tube for Medical Gas Systems Piping, Copper ASTM B ASTM C Making Capillary Joints by Soldering of Copper and Copper Tube and Fittings Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe , Joints , Piping, Non- Metallic ASTM C (R2004) e1 Asbestos-Cement Pressure Pipe Piping, Non- Metallic ASTM C a Concrete Drain Tile Piping, Non- Metallic ASTM C (R2009) ASTM C (R2006) ASTM C a e1 Compression Joints for Vitrified Clay Pipe and Fittings Asbestos-Cement Nonpressure Sewer Pipe (Notes 4 and 5) Joints for Concrete Pipe and Manholes, Using Rubber Gaskets Joints Table 71, 701.1, Table 64, , Piping, Non- Table 71, 701.1, Metallic , 715.0, Joints ,

8 ASTM C Precast Reinforced Concrete Manhole Sections ASTM C a 2009a ASTM C a 2009 ASTM C (R2005) ASTM C ASTM C a ASTM C Rubber Gaskets for Cast Iron Soil Pipe and Fittings Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications (Note 1) Flexible Transition Couplings for Underground Piping Systems Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems Joints , Piping, Non- Metallic Piping, Non- Metallic Table 71, 701.1, 701.2, Joints , Joints , Joints , , ASTM C ASTM C ASTM C a ASTM D (R2005)* ASTM D Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste, and Vent (DWV), Sewer, Sanitary, and Storm Plumbing Systems for Above and Below Ground Use Heavy Duty Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedule 40 and 80 Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds Joints , Joints , , , , Joints , Piping, Plastic Table 7-1, 701.1, , Piping, Plastic ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 120 Piping, Plastic Table 3-2, Table 6-4, 604.1, Table 7-1, 701.1, 903.1, , , ASTM D (R2005) e1 Rubber O-r Rings for Asbestos-Cement Pipe Joints ASTM D * Polyethylene (PE) Plastic Pipe, Schedule 40 Piping, Plastic ASTM D * ASTM D * ASTM D * 2009 ASTM D * ASTM D * ASTM D * ASTM D * ASTM D * Solvent Cement for Acrylonitrile-Butadiene- Styrene (ABS) Plastic Pipe and Fittings Polyethylene (PE) Plastic Pipe, (SDR-PR) Based on Controlled Inside Diameter Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 (Note 1) Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 (Note 1) Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 (Note 1) Joints Piping, Plastic Table 6-4, Piping, Plastic Table 6-4, Piping, Plastic Piping, Plastic Fittings Table 6-4, Fittings Table 6-4, Fittings Table 6-4,

9 ASTM D b 2009* ASTM D * ASTM D e1 * ASTM D (R2008)* ASTM D * ASTM D * Thermoplastic Gas Pressure Pipe, Tubing, and Fittings (Note 1) Reinforced Epoxy Resin Gas Pressure Pipe and Fittings Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe (Note 1) Heat Fusion Joining of Polyolefin Pipe and Fittings (Note 1) Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings (Note 1) Piping, Plastic , , , (B), (B), Appendix E Piping, Plastic 301.0, Appendix E Joints Joints Fittings Table 6-4, Joints 301.0, Piping, Plastic Table 71, 701.1, 701.2, 707.1, 903.1, , ASTM D * ASTM D a (R2003) (R2009)* ASTM D (R2009)* ASTM D * ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings Piping, Plastic Table 7-1, 701.1, 701.2, 707.1, 903.1, , Joints for IPS PVC Pipe Using Solvent Cement Joints Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Composite Sewer Piping Socket-Type Polyethylene Fittings for Outside Diameter-Controlled Polyethylene Pipe and Tubing Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings (Note 1) Piping, Plastic Table 7-1, 701.1, Fittings Table 6-4, Piping, Plastic , ASTM D * Polyethylene (PE) Plastic Tubing Piping, Plastic Table 6-4, ASTM D * ASTM D e1 2008* ASTM D b* ASTM D (R2002)* ASTM D (R2007) e1 * Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings (Note 1) Underground Installation of Thermoplastic Pressure Piping Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings Filament-Wound Fiberglass (Glass-Fiber- Reinforced Thermosetting-Resin) Pipe Piping, Plastic , Piping, Plastic Piping, Plastic Table 6-4, Joints Piping, Plastic ASTM D * ASTM D * ASTM D (R2002) (R2009)* ASTM D * ASTM D (R2005)* Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Polyethylene (PE) Plastic Pipe (DR-PR) (Based on Controlled Outside Diameter) Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and Fittings Solvent Cements for Transition Joints, Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-Pressure Piping Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals Piping, Plastic Piping, Plastic Table 6-4, 604.1, Joints Joints Joints

10 ASTM D a (R2003) e1 2007* ASTM D * ASTM D a 2009a* ASTM D * ASTM D * 2009 Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing Drain, Waste, and Vent (DWV) Plastic Fittings Patterns (Note 1) Rigid Acrylonitrile-Butadiene-Styrene (ABS) Materials for Pipe and Fittings Chlorinated Polyethylene (CPE) Sheeting for Concealed Water-Containment Membrane Joints Fittings Table 6-4, Fittings Piping, Plastic Fixtures ASTM D * 2009 Polypropylene Injection and Extrusion Materials , 701.2, ASTM D (R2001) (R2008) e1 * ASTM D (R2003) ASTM E b 2009c* Poly(Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-Containment Membrane Determining the Performance of Oil/Water Separators Subjected to Surface Run-Off Surface Burning Characteristics of Building Materials Fixtures Fixtures , , , ASTM E a 2009c* Fire Tests of Building Construction and Materials , ASTM E * ASTM F * Fire Tests of Through-Penetration Fire Stops Firestop Systems Safe Handling of Solvent Cements, Primers, and Cleaners Used for Joining Thermoplastic Pipe and Fittings 313.7, , , , , , Joints ASTM F * Corrugated Polyethylene (PE) Pipe and Fittings Piping, Plastic ASTM F (R2008)* ASTM F * ASTM F * ASTM F * ASTM F * ASTM F (R2005) 2009* ASTM F (R2004) e1 (R2009) ASTM F b* Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings (Note 1) Threaded Chlorinated Poly (Vinyl Chloride)(CPVC) Plastic Pipe Fittings, Schedule 80 Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Grab Bars and Accessories Installed in the Bathing Area Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), Schedule 40 and Schedule 80 Piping, Plastic Fittings Table 6-4, Fittings Table 6-4, Fittings Table 6-4, Piping, Plastic Table 6-4, Piping, Plastic Table 6-4, Piping, Plastic ASTM F * Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings Joints

11 ASTM F e1 2008* Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core (Note 1) Piping, Plastic Table 7-1, 701.1, 701.2, 903.1, ASTM F * ASTM F * ASTM F a 2008* ASTM F * ASTM F * Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings Large Diameter Corrugated Polyethylene Pipe and Fittings Polyethylene (PE) Plastic Pipe (SDR-PR) (Based on Outside Diameter) Poly (Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diameter Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Waste Disposal Absorption Fields Joints Piping, Plastic Piping, Plastic Piping, Plastic Table 7-1, 701.1, 701.2, 715.0, Piping, Plastic ASTM F * Crosslinked Polyethylene (PEX) Tubing Piping, Plastic Table 6-4, 604.1, ASTM F * ASTM F * Crosslinked Polyethylene (PEX) Plastic Hot- and Cold-Water Distribution Systems Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core Piping, Plastic Table 6-4, 604.1, Piping, Plastic Table 7-1, 701.1, 903.1, ASTM F * ASTM F a 2009* ASTM F (R2006)* ASTM F b 2009* ASTM F * ASTM F * ASTM F * ASTM F * ASTM F e1 2009* ASTM F * Polyethylene (PE) Large Diameter Profile Wall Sewer and Drain Pipe Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a Smooth Interior and Fittings Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Tubing Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin- Impregnated Tube Crosslinked Polyethylene/Aluminum/ Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe Polyethylene/Aluminum/Polyethylene (PE-AL- PE) Composite Pressure Pipe Pressure-Rated Composite Pipe and Fittings for Elevated Temperature Service Poly (Vinyl Chloride) (PVC) Gasketed Sewer Fittings Polyolefin Pipe and Fittings for Corrosive Waste Drainage Systems Performance of Gasketed Mechanical Couplings for Use in Piping Applications Piping, Plastic Piping, Plastic Fittings 301.2, Table 6-4, Piping, Plastic Piping, Plastic Table 6-4, 604.1, Piping, Plastic Table 6-4, 604.1, Piping, Plastic Fittings Piping, Plastic Joints ASTM F * Coextruded Composite Pipe Piping, Plastic Table 7-1, ASTM F (R2008)* ASTM F (R2009)* Coextruded Composite Drain, Waste, and Vent Pipe (DWV) Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems Piping, Plastic Piping, Plastic

12 ASTM F (R2003) 2008* Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP) ASTM F a e1 2008* Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing ASTM F * Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings ASTM F * ASTM F * ASTM F a 2009* ASTM F a* ASTM F * ASTM F * ASTM F * ASTM F (R2006)* ASTM F ASTM F e1 2008* ASTM F * Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing Metallic Mechanical Fittings for Use on Outside Diameter Controlled Thermoplastic Gas Distribution Pipe and Tubing Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing Metal Mechanical Cold Flare Compression Fittings with Disc Springs for Cross-linked Polyethylene (PEX) Tubing Special Engineered Fittings, or Appurtenances or Valves for Use in Poly (Vinyl Chloride)(PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11) and Polyamide 12 (PA12) Distribution Systems Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe Multilayer Pipe Type 2, Compression Fittings, and Compression Joints for Hot and Cold Drinking-Water Systems Cold-Expansion Fittings With Metal Compression-Sleeves for Crosslinked Polyethylene (PEX) Pipe Stainless Steel Clamps for Securing SDR9 Crosslinked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing Piping, Plastic Joints Table 6-4, 604.1, Piping, Plastic Fittings Fittings Fittings Table 7-1, 701.1, 701.2, 903.1, Fittings Table 6-4, 604.1, Fittings Table 6-4, 604.1, Piping, Plastic Table 6-4, , (B) Joints Table 6-4, 604.1, Fittings 301.0, Fittings Table 6-4, 604.1, Joints Joints Table 6-4, 604.1, ASTM F (R2008)* Flexible Pre-Insulated Piping Piping, Plastic ASTM F * ASTM F * ASTM F * Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene Tubing OD Controlled SDR9 Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/ Aluminum/Cross-linked Polyethylene (PEX-AL- PEX) Tubing Field-Assembled Anodeless Riser Kits for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing Piping, Plastic Table 6-4, 604.1, Joints Table 6-4, 604.1, , (B) 12

13 AWS A * Specification for Filler Metals for Brazing and Braze Welding Joints AWS B Brazing Procedure and Performance Qualification Certification , AWS B * Welding Procedure and Performance Joints, , (B) Qualification for Thermoplastics Certification AWWA C * Ductile-Iron and Gray-Iron Fittings for Water (same as ANSI A 21.10) Fittings Table 6-4, AWWA C * Rubber-Gasket Joints for Ductile-Iron Pressure Joints Pipe and Fittings (same as ANSI A 21.11) AWWA C * Ductile-Iron Pipe, Centrifugally Cast, for Water Piping, Table 6-4, AWWA C * Ductile-Iron Compact Fittings for Water Service Fittings Table 6-4, AWWA C * AWWA C * AWWA C * Coal-Tar Protective Coatings and Linings for Steel Water Pipelines - Enameled and Tape Hot Applied Fusion-Bonded Epoxy Coating for the Interior and Exterior of Steel Water Pipelines Extruded Polyolefin Coatings for the Exterior of Steel Water Pipelines AWWA C * Asbestos-Cement Pressure Pipe, 4 in. through 16 in. (100 mm through 400 mm) for Water Distribution Systems and Transmission AWWA C * Metal-Seated Service Gate Valves for Water Supply Service Piping, Non- Metallic Valves AWWA C * Rubber Seated Butterfly Valves Valves AWWA C * AWWA C * AWWA C * Ball Valves, 6 in. through 48 in. (150 mm through 1200 mm) Double Check Valve Prevention Assembly Reduced-Pressure Principle Prevention Assembly Valves AWWA C * Grooved and Shouldered Joints Joints AWWA C * Polyvinyl Chloride (PVC) Pressure Pipe, and Fabricated Fittings, 4 in. through 12 in. (100 mm through 300 mm), for Water Transmission and Distribution AWWA C * Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. (13 mm) through 3 in. (76 mm), for Water Service AWWA C * Cross-Linked Polyethylene (PEX) Pressure Pipes, 1/2 in. (12 mm) through 3 in. (76 mm), for Water Service AWWA C * Injection-Molded Polyvinyl Chloride (PVC) Pressure Fittings, 4 in. Through 12 in. (100 mm tthrough 300 mm), for Water Distribution CGA C (R2008) Standard Color Marking of Compressed Gas Containers for Medical Use. Table 6-4, , , , , , , , , , , , Piping, Plastic Table 6-4, Piping, Plastic Table 6-4, Piping, Plastic 301.0, Fittings

14 CGA G Cleaning Equipment for Oxygen Service , , CGA S Pressure Relief Device Standards-Part 3- Stationary Storage Containers for Compressed Gases CGA V Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections CISPI CISPI CSA No (D) Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications (Note 1) Couplings for Use in Connection with Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Applications U.S. Requirements for Excess Flow Valves (Discontinued) Valves Chapter 13 Piping, Table 7-1, 701.1, 701.2, Joints , , Valves CSA A Concrete Pipe and Manhole Sections Piping 301.0, CSA B (R2008) General Requirements for Plumbing Fixtures Fixtures 401.1, 402.1, 402.2, 402.3, 411.5, 411.6, 411.7, 411.8, CSA B CSA B CSA B CSA B Ceramic Plumbing Fixtures (Replaced with ASME A /CSA B Ceramic Plumbing Fixtures) Enameled Cast-Iron Plumbing Fixtures (Replaced with ASME A /CSA B Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures) Porcelain-Enamelled Steel Plumbing Fixtures (Replaced with ASME A /CSA B Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures) Stainless Steel Plumbing Fixtures (Replaced with A /CSA B Stainless Steel Plumbing Fixtures) Fixtures 401.1, 402.1, 402.2, 402.3, Fixtures 401.1, Fixtures 401.1, 402.1, 413.0, 414.0, Fixtures 401.1, 402.1, 402.2, 402.3, 411.6, 411.7, 414.0, CSA B (R2008) Plastic Plumbing Fixtures Fixtures 401.1, 401.2, 402.2, 402.3, 414.0, CSA B (R2008) Macerating Systems and Related DWV CSA B (R2006) Hydromassage Bathtubs Fixtures 401.1, CSA B Glass Lavatories Fixtures CSA B Preventers and Vacuum Breakers CSA B Atmospheric Vacuum Breakers (AVB) CSA B Pressure Vacuum Breakers (PVB) CSA B Hose Connection Vacuum Breakers (HCVB) CSA B (R2006) Hose Connection Dual Check Vacuum Breakers, 2007 Hose Connection Dual Check Type (HCDVB) CSA B Reduced Pressure Principle (RP) Preventers (RP) , , , , , , , ,

15 CSA B (R2006) 2007 CSA B (R2006) 2007 CSA B (R2006) 2007 Reduced Pressure Principle Preventers for Fire Systems (RPF) Double Check Valve (DVCA) Preventers Double Check Valve Preventers for Fire Systems (DVCAF) CSA B Laboratory Faucet Vacuum Breakers (LFVB) CSA B Floor Drains, Area Drains, Shower Drains, and DWV Cleanouts for Residential Construction Commercial and Residential Drains and Cleanouts CSA B Plumbing Fittings Valves Fittings CSA B /B Design and Installation of Non-Potable Water Systems/Maintenance and Field Testing of Non- Potable Water Systems (Note 1) , , , , , , , , , , , , , , 411.0, , 407.7, 410.0, 413.1, 414.5, 416.3, Table , , CSA B CSA B CSA B CSA B Polyethylene (PE) Pipe, Tubing, and Fittings for Cold-Water Pressure Services Crosslinked Polyethylene (PEX) Tubing Systems for Pressure Applications Polyethylene/Aluminum/Polyethylene (PE-AL- PE) Composite Pressure-Pipe Systems Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe Systems Piping, Plastic Table 6-4, Piping, Plastic Table 6-4, 604.1, , , Piping, Plastic Table 6-4, 604.1, , , Piping, Plastic Table 6-4, 604.1, , , CSA B CSA B CSA B (R2005) Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems Groove- and Shoulder-Type Mechanical Pipe Couplings Water Pressure Reducing Valves for Domestic Water Supply Systems Piping, Plastic Fittings Valves 608.2, CSA G Corrugated Steel Pipe Products Piping, CSA LC Piping Systems Using Corrugated Stainless Steel Tubing (CSST) (same as CSA 6.26) CSA LC3-2000* Appliance Stands and Drain Pans CSA LC Press-Connect Copper and Copper Fittings for Use in Distribution Systems (same as CSA 6.32) CSA Z21.5.1a * CSA Z21.5.2a-2006* Gas Clothes Dryers -Volume I-,Type 1 Clothes Dryers (same as CSA 7.1a) Gas Clothes Dryers -Volume 2 II-,Type 2 Clothes Dryers (same as CSA 7.2a) ,

16 CSA Z ab * Gas Water Heaters Volume I, Storage Water Heaters with Input Ratings of Btu pper Hour or Less (same as CSA 4.1a) CSA Z ba * Gas Water Heaters Volume III, Storage Water Heaters, with Input Ratings Above Btu pper Hour, Circulating and Instantaneous (same as CSA 4.3b) CSA Z21.12b-1994 (R2000) * Draft Hoods CSA Z21.13b-2007* CSA Z21.15b * Gas-Fired Low Pressure Steam and Hot Water Boilers (same as CSA 4.9b) Manually Operated Gas Valves for, Appliance Connector, Valves, and Hose End Valves (same as CSA 9.1) Valves , CSA Z21.22b-2001 (R2003) (R2008)* CSA Z21.24a * CSA Z a-1997 (R2002)* CSA Z21.41a-2005* Relief Valves for Hot Water Supply Systems (same as CSA 4.4b) Connectors for Gas (same as CSA 6.10a) Quick Connect Devices for Use With Gas Fuel Gas-Fired, Heat Activated Air Conditioning and Heat Pump (same as CSA 2.91a) Quick-Disconnect Devices for Use with Gas Fuel (same as CSA 6.9a) Valves 608.4, 608.5, 608.6, Joints Fuel Gas, Joints CSA Z21.47ab * Gas-Fired Central Furnaces (same as CSA 2.3b) CSA Z21.56a * Gas-Fired Pool Heaters (same as CSA 4.7a) Swimming Pools, and Spas, and Hot Tubs CSA Z21.69b * Connectors for Movable Gas (same as CSA 6.16) , , Table 12-1, UMC USPSHTC , CSA Z21.80a-2005 (R2008)* Line Pressure Regulators (same as CSA 6.22a) , , (A,1) CSA Z21.81a-2007* Cylinder Connection Devices (same as CSA 6.25a) CSA Z21.86b * Vented Gas-Fired Space Heating (same as CSA 2.32) 501.0, (6), (4), Table 12-1, UMC CSA Z83.11b * Gas Food Service Equipment (same as CSA 1.8b) 501.0, Table 12-1 CSA Z (R2002) 2009* Special Requirements for Plumbing Installations in Health Care Facilities FCI (D) IAPMO IGC a 2009 Spring Loaded Lift Disc Check Valve (Discontinued) Tub/Shower Enclosures and with Factory- Installed Fittings, Shower Panel, Shower Door, and Threshold Assemblies Valves Fixtures 401.1, IAPMO IGC a Ball Valves Valves 301.0, 605.1, IAPMO IGC Glass Lavatories, and Sinks and Counter Tops Fixtures IAPMO IGC Safety Plates and Plate Straps 301.0, IAPMO IGC a Copper or Aluminum Sinks and Lavatories Fixtures

17 IAPMO IGC Metallic Bathtubs, Shower Pans and Whirlpool Bathtubs Fixtures 401.1, IAPMO IGC a Drinking Water Fountains With or Without Fixtures Chiller or Heater IAPMO PS a Dishwasher Drain Airgaps , IAPMO PS IAPMO PS a 2009d IAPMO PS IAPMO PS IAPMO PS IAPMO PS IAPMO PS Metallic Fittings for Joining Polyethylene Pipe for Water Service and Yard Piping Flexible PVC Hose for Pools, Hot Tubs, Spas and Jetted Bathtub Encasement Sleeve for Potable Water Pipe and Tubing Lead Free Sealing Compounds for Threaded Joints Black Plastic PVC or PE Pressure-Sensitive Corrosion Preventive Tape Pipe Alignment and & Secondary Support Systems Cushioned Bathtubs and Whirlpool Bathtub Joints , USPSHTC Swimming Pools, Spas, and Hot Tubs Piping Joints , , , , Fixtures 401.1, IAPMO PS a 2008 Field-Fabricated Tiling Kits Table 4-1 (Note 10), IAPMO PS Flush Valves with Dual Flush Devices For Water Closets or Water Closet Tank with an Integral Flush Valves with a Dual Flush Device Fixtures 410.1, IAPMO PS Plastic and Metallic Expansion Joints Joints , , IAPMO PS Pump/Dose, Sumps and Sewage Ejector Tanks with or without a Pump DWV 710.8, IAPMO PS Grooved Mechanical Pipe Couplings and Grooved End Fittings Joints IAPMO PS Metallic and Plastic Utility Boxes IAPMO PS Bathwaste Strainer Drains Fixtures IAPMO PS PVC Hydraulically Actuated Diaphragm Type Valves Water Control Valves IAPMO PS Septic Effluent and Waste Water Diverter Valves DWV IAPMO PS Sewage Holding Tank Containing Sewage Ejector Pump for Direct Mounted Water Closet DWV IAPMO PS a (D) Fabricated Stainless Steel Water Closets or Urinals (Discontinued) Fixtures 401.1, 402.1, 402.2, 410.0, IAPMO PS Plastic Leaching Chambers DWV IAPMO PS a Pipe Flashings 313.8, IAPMO PS Airgap Units for Water Conditioning Equipment Installation IAPMO PS Dielectric Waterway Fittings Fittings IAPMO PS Early-Closure Replacement Flappers or Early- Closure Replacement Flapper With Mechanical Assemblies Fixtures ,

18 IAPMO PS Bathwaste and Overflow Assemblies with Tub Filler Spout Piping, Plastic DWV IAPMO PS Valves with Atmospheric Vacuum Breakers Valves IAPMO PS Dental Vacuum Pumps IAPMO PS Ballcock or Flushometer Valve Tailpiece Trap Primers and Trap Primer Receptors/Adapters DWV IAPMO PS Multiport Electronic Trap Primer DWV IAPMO PS Clarifiers DWV IAPMO PS Precast Concrete Seepage Pit Liners and Covers DWV IAPMO PS Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Fittings Fittings IAPMO PS Tools for Mechanically Formed Tee Connections in Copper Tubing IAPMO PS Rainwater Diverter Valve for Non-Roofed Area DWV 301.0, Slabs IAPMO PS Diverter and Shutoff Valves for Pool/Spas Valves, USPSHTC Swimming Pools, and Spas, and Hot Tubs IAPMO PS Pre-Pressurized Potable Water Tanks 301.0, 608.6, 608.7, IAPMO PS Soaking and Hydrotherapy (Whirlpool) Bathtubs Fixtures with Hydraulic Seatlift IAPMO PS Elastomeric Test Caps/Cleanout Caps DWV IAPMO PS a Plastic Stabilizers for Use with Plastic Closet Piping, Plastic Bends DWV IAPMO PS a 2008a Heat Exchangers , , Appendix L 3.0 IAPMO PS a (D) Water Closets with Spray, Water Closet Seats Fixtures with Spray and Other Devices with Spray for Water Closets Supplied with Hot and Cold Water (Discontinued) IAPMO PS a 2008 P-Trap, Supply Stop and Riser Insulated Protector IAPMO PS Drain, Waste, and Vent Hangers and Plastic Pipe Support Hooks Piping Fixtures DWV IAPMO PS Passive Direct Solar Water Heaters USEC IAPMO PS Prefabricated Fiberglass Church Baptisteries Fixtures IAPMO PS Terrazzo, Marble, Concrete, Granite, and Slate, and Granite Plumbing Fixtures Fixtures IAPMO PS Porous Filter Protector for Sub-drain Weep Holes DWV IAPMO PS Suction Relief Valves Valves IAPMO PS Pressure Relief Connection for Dispensing Valves Equipment IAPMO PS Polyethylene Distribution Boxes DWV Appendix K 6 IAPMO PS Pre-fabricated, Tileable Shower Receptors Fixtures 411.5, 411.6,

19 IAPMO PS Aramid Reinforced Rubber Hose for Use in Non- Potable Water Radiant Heating and SnowmMelting Piping, Plastic IAPMO PS Grease Restaurant Fire Suppression Systems IAPMO PS a PVC Cold Water Compression Fittings Fittings IAPMO PS PVC Cold Water Gripper Fittings Fittings IAPMO PS IAPMO PS e1 IAPMO PS e1 IAPMO PS IAPMO PS PVC Plastic Valves for Cold Water Distribution Systems Outside a Building and CPVC Plastic Valves for Hot and Cold Water Distribution Systems Hydraulically Powered Household Food Waster Disposers Remote, Floor Box Industrial Water Supply, Air Supply, Drainage Hot Water On-Demand or Automatic Activated Hot Water Pumping Systems Hot Water Circulating Devices Which Do Not Use a Pump UMC Valves , 404.4, , IAPMO PS Copper and Copper Tubing System Fittings Incorporating Fittings with Press-Type or Nail- Type Connections For Installation on Copper Tubing IAPMO PS Water Energized Sump Pump IAPMO Z * Plastic Bathtub and & Shower Units Fixtures 401.1, IAPMO Z * Plastic Lavatories Fixtures IAPMO Z * Plastic Water Closet Bowls and Tanks Fixtures IAPMO Z * Plastic Toilet (Water Closet) Seats Fixtures IAPMO Z * Plastic Sinks Fixtures IAPMO Z * Prefabricated Plastic Spa Shells Fixtures, Swimming Pools, and Spas, and Hot Tubs 401.1, 414.0, USPSHTC IAPMO Z * Plastic Bathtub Liners Fixtures 401.1, IAPMO Z * Plastic Urinal Fixtures (Note 1) Fixtures IAPMO Z * Prefabricated Septic Tanks DWV Appendix K 5(N) IAPMO Z * Prefabricated Gravity Grease Interceptors Fixtures DWV ICC A * Accessible and Usable Buildings and Facilities Table 4-1, ISEA Z * Emergency Eyewash and Shower Equipment ISO Guide MSS SP MSS SP * 2008 MSS SP * 2009 General Requirements for Bodies Operating Product Certification Systems Finishes for Contact Faces of Pipe Flanges and Connecting-End Flanges of Valves and Fittings Standard Marking System for Valves, Fittings, Flanges, and Unions Class 150 Corrosion Resistant Gate, Globe, Angle, and Check Valves with Flanged and Butt Weld Ends (Classes 150, 300 & 600) Certification Piping, MSS SP * Steel Pipeline Flanges Fittings

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN CHAPTER 14 STANDARDS Note: Referenced sections will be updated before publishing. 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

STANDARDS TASK GROUP REPORT

STANDARDS TASK GROUP REPORT STANDARDS TASK GROUP REPORT THE SCOPE OF THE STANDARDS TASK GROUP INCLUDES ADDING CROSS- REFERENCES TO TABLE 14-1 AND RECOMMEND WHERE SUCH REFERENCES ARE APPLICABLE TO THE REFERENCED STANDARDS AND TO UPDATE

More information

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS 19.1 REFERENCED STANDARDS Referenced Standards Chapter 19 Table 19.1 lists the standards that are referenced within the requirements of this Code. Table 19.1 shows the designation number of the standard,

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES November 21, 2017 Part I: Approved Listing Agencies Part II: Approved Testing

More information

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1 CHAPTER 14 MANDATORY REFERENCED STANDARDS AHAM DW-1-92 Household Electric Dishwashers Appliances AHAM DW-2PR-92 Plumbing Requirements for Household Dishwashers Appliances AHAM FWD-1-92 Food Waste Disposers

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES July 25, 2018 Part I: Approved Listing Agencies Part II: Approved Testing

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA 2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA I. Call to Order II. Chairman Comments III. Announcements IV. Self Introductions

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications 1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments TABLE OF CONTENTS I Tentative Agenda II Tentative Order of Discussion III A2L Task Group Report IV Uniform Mechanical Code Change Public Comments 2017 Uniform Mechanical Code Technical Committee Meetings

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type. PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018, STANDARDS Chapter 17, Part II CHAPTER 17 STANDARDS 1701.0 Scope Part I of this chapter covers standards that are hereby declared to be part of this code. Part II of this chapter lists standards which relate

More information

SECTION BASIC MATERIALS AND METHODS

SECTION BASIC MATERIALS AND METHODS SECTION 15050 BASIC MATERIALS AND METHODS PART 1 1.1 SECTION INCLUDES A. General Conditions B. Supplementary Conditions C. Division 1 D. Mechanical basic requirements E. Electric Motors F. Pipe, Valve,

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS). PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following: 1. Hot-water

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

NFPA 54 UPDATE. Paul Cabot American Gas Association

NFPA 54 UPDATE. Paul Cabot American Gas Association NFPA 54 UPDATE Paul Cabot American Gas Association PRESENTATION TOPICS Summary Listing Schedule Revisions Definitions/General Piping Appliances and Appliance Installation Venting 2015 Edition Revision

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point. PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems CHAPTER 15 REFERENCED STANDARDS SECTION MC 1501 GENERAL 1501.1 General. This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS 22 00 70 (November 2011) Change 1-08/17 ----------------------------- Preparing Activity: USACE Superseding UFGS 22 00 70 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS AG AVB PVB DCVA PA 1 Abattoir (slaughter house) 2 Air compressor oil cooler 3 Agricultural chemicals (sprayers 4 Animal watering 5 Apartment building (within the scope of Part 3 of the Ontario Building

More information

REFRIGERANT PIPING

REFRIGERANT PIPING SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

A. Section Joint Sealants: Seal fixtures to walls and floors.

A. Section Joint Sealants: Seal fixtures to walls and floors. SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2

More information

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub. CHAPTER 2 DEFINITIONS 201.0 General. For the purpose of this code, the following terms have the meanings indicated in this chapter. No attempt is made to define ordinary words which are used in accordance

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

$0.98 $ KITCHEN SINK STRAINER, 3-1/2 x BATH TUB DRAIN, 1-15/16 x 2-3/4 x $ $1.89 *s are Subject to Change without Notice.* WASHERS Rubber Beveled 5-1915 CLOSET, 3/8" O.D. TUBE $0.20 5-1916 CLOSET, 1/2" O.D. TUBE $0.20 5-1917 LAVATORY, 1/2" TALL x 3/8" O.D. $0.20 TUBE 5-1849 LAVATORY,

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

GENERAL PLUMBING REQUIREMENTS

GENERAL PLUMBING REQUIREMENTS 22 00 00 GENERAL PLUMBING REQUIRMENTS i. 00 00 07 Design Professional Design Process Requirements ii. 00 00 08 Design Professional Documentation Requirements and Deliverables iii. 01 81 00 Facility Performance

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 2113 - HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and certain specialties for the following: 1. Chilled

More information

8501 E. Pleasant Valley Rd. Cleveland, OH 44131

8501 E. Pleasant Valley Rd. Cleveland, OH 44131 IAS Accreditation Number Company Name Address Contact Name TL-266 8501 E. Pleasant Valley Rd. Cleveland, OH 44131 Benjamin Barker Manager, Accreditations Telephone (416)747-4013 Effective Date of Scope

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

1. Division 22 Section Emergency Plumbing Fixtures. 2. Division 22 Section Drinking Fountains and Water Coolers. Page 224000-1 SECTION 224000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Uniform Plumbing Code (UPC) 5/2018 Hearings Notes J. Kendzel, ASA VP Advocacy

Uniform Plumbing Code (UPC) 5/2018 Hearings Notes J. Kendzel, ASA VP Advocacy 001 002 003 004 005 006 007 102.3 Maintenance. Devices, equipment, or safeguards required by this code shall be maintained in accordance with the manufacture's maintenance instructions so that a hazard

More information