1 record your global partner for entrance solutions User manual service display record FlipFlow your global partner for entrance solutions record.group automatic door systems this is record!

2 Table of contents Table of contents 1 Instructions Connecting the Service Display Operating modes General presentation Commissioning the record Service Display Enter the access code Parameter display Page layout Parameter overview Description of the parameters Alarm list Display symbols (eample) FlipFlow alarm list V4.0 2/ 45

3 Instructions Instructions Connecting the Service Display Connect the Service Display to one of the sockets on the control board or on the cladding of the entrance and/or eit door (optional). IMPORTANT Please ensure that the ON / switch is on before connecting and/or disconnecting the Service Display. CAUTION Note: If the display is on (switch in the ON position) while being connected / disconnected this can lead to destruction of the control interface. Pull down the service flap to access the main control board and connect the service display V4.0 3/ 45

4 Operating modes Operating modes General presentation The screen displays error messages in plain tet as well as the type of configuration. The menu can be accessed by turning the blue rotary dial on the front of the Service Display as shown in the diagram below: Scroll through the menu using the blue dial. Press the dial once briefly to confirm your menu selection. Keep the dial pressed to return to the previous menu. Accessing information in the menu: The cursor shows your position in the menu. Turn the dial to scroll V4.0 4/ 45

5 Operating modes Commissioning the record Service Display Before using the record Service Display, it has to be configured in order to communicate with the PLC (Programmable Logic Control). Accessing the SETUP menu on the screen: Connect the plug while keeping the rotary dial pressed. Setting the communication speed: Scroll down to Set Baudate and confirm Set to 9600 and confirm Return to the previous menu Selecting the communication mode: Select Set Serial Mode and confirm Select RS485 FTP and confirm Choice of address: 01 to add local address and confirm V4.0 5/ 45

6 Operating modes 2 02 to add technician s info and confirm Change the address screen: Return to the communication mode Eit Serial Mode menu And eit the Setup menu 2.3 Enter the access code Access to the menu is protected by a code which restricts modification of the parameter settings to qualified and authorized personnel only. No code is required to view the settings. Simply confirm to proceed to the net menu. Contact your record partner to obtain your access code V4.0 6/ 45

7 Parameter display Parameter display Page layout This page contains the following: Current program details Number of passages (number of passengers that have passed through the FlipFlow) An information message (current operating mode, maintenance required., etc.) Configuration details Alarm details System date and time V4.0 7/ 45

8 Parameter overview 4 4 Parameter overview V4.0 8/ 45

9 Parameter overview V4.0 9/ 45

10 Parameter overview V4.0 10/ 45

11 Parameter overview V4.0 11/ 45

12 Parameter overview V4.0 12/ 45

13 Parameter overview V4.0 13/ 45

14 Parameter overview V4.0 14/ 45

15 Parameter overview V4.0 15/ 45

16 Parameter overview V4.0 16/ 45

17 5 Description of the parameters MENU CONFIG. Parameter Value (Default values are bold) Description TWIN TRIPLE WIDE EXTENDED DOOR SYSTEM PDoorType TWIN Select door type: TWIN / TRI / WIDE PEtended ON: with etended gate : without etended gate PARAMETERS W COMMENT CUSTOMER Customer 0 Select customer: 0 = Standard 1 = Schiphol Airport 2 = Toronto Airport 3 = ADP 4 = USA 5 = Nice DOOR OPERATING PReOpen ON ON: door opens and reverses in the standard operating mode when an opening impulse is detected by the radar. : door closes completely first and then can open again once an opening impulse is detected by the radar. TReOpen 10 (ds) There is a delay time when PReOpen in on and the door is closed before a new door opening is performed. PBdeSType Bde1 Bde1 = Locked Open- Flow Interlock - Automatic Bde2 = Locked Flow Automatic Interlock Maintenance *BDE-S Type is only used for FlipFlow TWIN V4.0 17/ 45

18 OPERATING MODES LOCKED mode PDetection Protection against confinement in the LOCKED operating mode. ON: detection in the tunnel opens the eit door. : tunnel closes and locks (danger of confinement). FLOW mode TClosIn 5 (ds) Hold open time entrance door TClosMid 5 (ds) Hold open time middle door TClosOut 5 (ds) Hold open time eit door INTERLOCK mode (not applicable for WIDE) TClosIn 5 (ds) Hold open time entrance door TClosMid 5 (ds) Hold open time middle door TClosOut 5 (ds) Hold open time eit door TWait 4 (ds) Delay time for opening the middle and eit door after the entrance door is closed. PMaPers 3 Number of passengers allowed to enter before the entrance door closes. PBlinkType 0 Adjusting the traffic lights in the INTERLOCK mode: 0 = Green on and red blinking 1 = Red on green blinking 2 = Green and red blink alternatively 3 = Green blinking TBlink 5 (ds) Blinking speed of the traffic lights V4.0 18/ 45

19 AUTOMATIC mode (not applicable for WIDE) Pers.LimitHig 650 (P/h) When the limit is reached, the system switches to FLOW mode. Pers.LimitLow 450 (P/h) If the number of passengers is low, the system switches to INTERLOCK mode. Pers.Count15s (read only) Number of passengers every 15 seconds. Pers./h (P/h) (read only) Number of passengers per hour. OPEN mode PDetection ON ON: Tunnel monitoring and pass back flow recognition. : Tunnel clear in both directions of passage. CLEANING mode TRunTime 10 (min) Duration of time after the operating mode has automatically ended. TWarn 100 (ds) Warning interval after the duration of time signaling the tunnel should be cleared has epired. PCleanArea Land Set from which area (Land / Air) the tunnel can be entered. TEnterDelay 20 (ds) Delay time before the operating mode starts once the tunnel is empty. MAINTENANCE mode TBlink 25 (ds) Blinking speed of the traffic lights. PMntArea Land Set from which are (Land- / Air) the tunnel can be entered. TEnterDelay 20 (ds) Delay time before the operating mode starts once the tunnel is empty V4.0 19/ 45

20 HANDICAPPED mode (not applicable for WIDE) PTimeout ON: monitoring time enabled. : monitoring time disabled. TTimeout 60 (s) Duration of time after the operating mode has automatically ended. TWarn 50 (ds) Warning interval after the duration of time signaling the tunnel should be cleared has epired. TAILGATING mode (not applicable for TWIN or TRIPLE) Pactive ON: Flow mode changes to Tailgating mode. : Standard WIDE with Flow mode TElsAlarm 20 (s) Maimum delay after activating the light beam counter and receiving the result of the tailgating sensor. TSensorError 100 (ds) Alarm delay, no sensor response TBootUp 45 (s) Alarm delay, sensor not initialized. INPUTS AuIn_01 0 Au Entrance 01 0 = Inactive 1 = Locked mode 2 = Open mode 3 = Flow mode 4 = Interlock mode AuIn_11 0 Au Entrance 11 AuIn_12 0 Au Entrance 12 AuIn_21 0 Au Entrance V4.0 20/ 45

21 AuIn_31 0 Au Entrance 31 0 Settings for the programmable inputs: 0 = Inactive 1 = Maintenance mode (enable / disable maintenance mode) 2 = Handicapped Entry Badge (enable the HANDICAPPED mode, open entrance and middle door) 3 = Handicapped Badge Tunnel (when HANDICAPPED mode is enabled, the entrance door closes and the eit door opens) 4 = Handicapped Eit Badge (in HANDICAPPED mode, all doors closed, the operating mode switches to the preset mode) 5 = PassBack Cam Entry Door (pass back sensors on the entrance door, for Breach alarm (only AuIn_11) 6 = Tailgate sensor (only for WIDE) only AuIn_11 7 = Locked mode 8 = Remote control enable 9 = Badge ALARMING General TAlarmTech 100 (ds) Delay time before triggering the technical alarm. PAutoReset ON Auto reset after resetting the back-up alarm or technical alarm. TAutoReset 15 (ds) Delay time before triggering the auto reset. TBuzzer 15 (ds) Buzzer interval. TClosIn 0 (ds) Hold open time entrance door. TClosMid 0 (ds) Hold open time middle door. TClosOut 0 (ds) Hold open time eit door. TBlinkTech 1 (ds) Blinking speed of the traffic lights V4.0 21/ 45

22 PFlashIn 2 Controlling the flashing lights entrance door. 0 = Technical alarm 1 = Intrusion alarm 2 = Alarm due to wrong direction PFlashOut 2 Controlling the flashing light eit door. 0 = Technical alarm 1 = Intrusion alarm 2 = Alarm due to wrong direction TFlashIn 0 (s) Duration of the signal output with enabled alarm 0 = Duration deactivated -> control permanent TFlashOut 0 (s) Duration of the signal output with enabled alarm 0 = Duration deactivated -> control permanent Pass back PCloseIn NSK Closing reaction of the entrance door. VRR: close and lock. NSK: emergency closing (without safety sensors) TPreAlarm 1 (ds) Delay before the pre-alarm is activated. TPreAlarm OnDelay 20 (ds) Delay time until the pre-alarm is reactivated. Detection after the closing process. PTwo- Trigger ON: before activating pass back alarm two pass back indicators are required : one pass back signal triggers an alarm Treset 40 (s) Delay before resetting pass back trigger counting Sensors tunnel (not applicable for WIDE) TFloorFlow 75 (ds) Alarm delay when detecting an object on the floor. TFloorInt 120 (ds) Alarm delay when detecting an object in the INTERLOCK operating mode V4.0 22/ 45

23 TVolumetric 100 (ds) Alarm delay when detecting an object volumetric in the tunnel. TCeiling 50 (ds) Alarm delay when detecting an object on the ceiling. TWall 50 (ds) Alarm delay when detecting an object on the side walls. Sensors etended TPrFloor 100 (ds) Alarm delay when detecting an object on the floor. Sensors pass back TPrPre- Alarm 100 (ds) Alarm delay when detecting an object in the pre-alarm area. Entrance door TDistOpen 100 (ds) Alarm delay, door is open and the sensor in the swing area or counter light barrier has been triggered. TWingClose 5 (ds) Alarm delay, door is closed and the sensor in the swing area has been triggered. TElsClose 100 (ds) Alarm delay, door is closed and the counter light barrier has been triggered. TWrongPos 100 (ds) Alarm delay, door will not open or close. Middle door (not applicable for Twin and Wide) TDistOpen 100 (ds) Alarm delay, door is open and the sensor in the swing area or counter light barrier has been triggered. TWingClose 5 (ds) Alarm delay, door is closed and the sensor in the swing area has been triggered. TElsClose 100 (ds) Alarm delay, door is closed and the counter light barrier has been triggered. TWrongPos 100 (ds) Alarm delay, door will not open or close V4.0 23/ 45

24 Eit door (not applicable for Wide) TDistOpen 100 (ds) Alarm delay, door is open and the sensor in the swing area or counter light barrier has been triggered. TWingClose 5 (ds) Alarm delay, door is closed and the sensor in the swing area has been triggered. TElsClose 100 (ds) Alarm delay, door is closed and the counter light barrier has been triggered. TWrongPos 100 (ds) Alarm delay, door will not open or close. Etended gate TWrongPos 100 (ds) Alarm delay, door will not open or close. LIGHT (not applicable for Wide) PPowerSave ON Energy saving mode TPowerSave 45 (min) Duration of time until the light goes off when the door is not being used. SPEECH OUTPUT TBetweenMsg 5 (min) Duration of time between messages. Pconfig One One: only one voice card is used All: all voice cards are activated. BMS CONTACTS Info ConfigNo (read only) dependent on the configuration. Contacts 1-8 PInLocked Status message entrance door. ON: closed and locked. : closed. PLogic1-01 PLogic1-02 PLogic1-03 PLogic1-04 Output logic ON: enabled when message is inactive V4.0 24/ 45

25 PLogic1-05 : enabled when message is active. PLogic1-06 PLogic1-07 PLogic1-08 Contacts 9-16 (not applicable for Etended) PLogic2-01 PLogic2-02 PLogic2-03 PLogic2-04 PLogic2-05 PLogic2-06 PLogic2-07 PLogic2-08 Output logic ON: enabled when message is inactive. : enabled when message is active V4.0 25/ 45

26 FUNCTIONS Default settings Load Set all parameters back to default settings. Factory settings Load Set all parameters back to factory settings. Learning Et. Gate (applies only to Etended) Positioning Disable the drives to allow the usual positioning to the closed position. Learn Start learning cycle. DIAGNOSTICS Status Sensors Tunnel 1 (not applicable for WIDE) PrFloor (read only) Object detection on the floor. PrElsFloor (read only) Object detection on the floor (light barrier). PrCeiling (read only) Object detection on the ceiling. PrElsCeiling (read only) Object detection on the ceiling (light barrier). PrVolumetric (read only) Volumetric object detection in the tunnel. PrWallLeft (read only) Object detection on the left wall. PrWallRight (read only) Object detection on the right wall. CamGo1 (read only) Pass back detection. CamGo2 (read only) Pass back detection. ServiceTrap (read only) Service trap is open V4.0 26/ 45

27 Tunnel 2 (not applicable for TWIN and WIDE)) PrFloor2 (read only) Object detection on the floor tunnel 2. PrElsFloo2 (read only) Object detection on the floor (light barrier) tunnel 2. PrCeiling2 (read only) Object detection on the ceiling tunnel 2. PrEls- Ceiling2 PrVolumetric2 (read only) Object detection on the ceiling (light barrier) tunnel 2. (read only) Volumetric object detection in tunnel 2. PrWallLeft2 (read only) Object detection on the left wall tunnel 2. PrWall- Right2 (read only) Object detection on the right wall tunnel 2. CamGoTri1 (read only) Pass back detection tunnel 2. CamGoTri2 (read only) Pass back detection tunnel 2. CamGoTri3 (read only) Pass back detection tunnel 2. CamGoTri4 (read only) Pass back detection tunnel 2. Service- Trap2 (read only) Service trap is open tunnel 2. Etended Gate (applies only to Etended) Gate1Open (read only) Wing gate 1 is open Gate1- Closed (read only) Wing gate 1 is closed Gate1Error (read only) Malfunction wing gate 1 Gate2Open (read only) Wing gate 2 is open Gate2- Closed (read only) Wing gate 2 is closed Gate2Error (read only) Malfunction wing gate V4.0 27/ 45

28 Software Inputs SwMaintenance Handicapped BadgeIn Handicapped BadgeTun Handicapped BadgeOut CamGo DoorIn Tailgate Sensor Mode Locked (read only) Maintenance mode. (read only) Signal status entrance badge for Handicapped mode. (read only) Signal status badge inside tunnel for Handicapped mode. (read only) Signal status eit side badge for Handicapped mode (read only) Signal status pass back cameras entrance door. (read only) Signal status of tailgating sensor (read only) Locked mode Mode Open (read only) Open mode Mode Flow (read only) Flow mode ModeInterlo ck (read only) Interlock mode COUNTER User Passenger (integer) (read only) Number of users Reset Reset the counter Cycle Entrance door Door (integer) (read only) Entrance door cycles Locking (integer) (read only) Entrance door locking cycles Reset Reset the counter V4.0 28/ 45

29 Middle door (not applicable for TWIN and WIDE) Door (integer) (read only) Middle door cycles Locking (integer) (read only) Middle door locking cycles Reset Reset the counter Eit door (not applicable for WIDE) Door (integer) (read only) Eit door cycles Locking (integer) (read only) Eit door locking cycles Reset Reset the counter Cycle etended gate (applies only to Etended) WingLeft (integer) (read only) Left wing cycles WingRight (integer) (read only) Right wing cycles Reset Reset the counter Alarms (only applies to Etended) TechAlarm (integer) (read only) Number of technical alarms FlowAlarm (integer) (read only) Number of flow disturbances WrongWay (integer) (read only) Number of wrong way alarms Intrusion (integer) (read only) Number of intrusions Tailgaiting (integer) (read only) Number of tailgating alarms Reset Reset the counter Operating time Light (h) (read only) Operating time for the lighting Reset Reset the counter V4.0 29/ 45

30 ALARM LIST Alarms Buffer (see alarm listing) INPUTS / OUTPUTS Inputs 0 15 PrElsIn ON / (read only) Counter light barrier entrance door PrElsOut ON / (read only) Counter light barrier eit door PrElsMid ON / (read only) Counter light barrier middle door Reserve ON / (read only) DoorOut- Open ON / (read only) Eit door open DoorMid- Open ON / (read only) Middle door open Reserve ON / (read only) DoorOut- Closed ON / (read only) Eit door closed DoorMid- Closed ON / (read only) Middle door closed Reserve ON / (read only) RadarIn ON / (read only) Motion detector entrance door RadarOut ON / (read only) Motion detector eit door RadarMid ON / (read only) Motion detector middle door Reserve ON / (read only) DoorInOpen ON / (read only) Entrance door open DoorIn- Closed ON / (read only) Entrance door closed PrWingIn ON / (read only) Swing area protection entrance door PrWingOut ON / (read only) Swing area protection eit door PrWingMid ON / (read only) Swing area protection middle door V4.0 30/ 45

31 Reserve ON / (read only) DoorIn- Locked ON / (read only) Entrance door locked DoorOut- Locked ON / (read only) Eit door locked DoorMid- Locked ON / (read only) Middle door locked Reserve ON / (read only) AlarmStgIn ON / (read only) Control alarm entrance door AlarmStg- Out ON / (read only) Control alarm eit door AlarmStg- Mid ON / (read only) Control alarm middle door Reserve ON / (read only) BDE-S 3 ON / (read only) BDE-S contact 3 Au11 ON / (read only) Programmable input 11 Inputs CamGo1 ON / (read only) Pass back detection 1 Reserve ON / (read only) CamGo2 ON / (read only) Pass back detection 2 Reserve ON / (read only) AC PowerFall ON / (read only) Power supply monitoring BDE-S 1 ON / (read only) BDE-S contact 1 BDE-S 2 ON / (read only) BDE-S contact 2 SwNoAlarm ON / (read only) No alarm switch SwCleaning ON / (read only) Cleaning operating mode switch PrFloor ON / (read only) Floor detection light barrier Reserve ON / (read only) PrVolumetric ON / (read only) Volumetric monitoring sensor V4.0 31/ 45

32 RadPre- Alarm ON / (read only) Pre-alarm motion detector SwEmerg- Eit RadPre- Alarm ON / (read only) Emergency open switch ON / (read only) Pre-alarm motion detector Reserve ON / (read only) Emerg- Closing Total- Opening ON / (read only) Emergency closing ON / (read only) Total open Au01 ON / (read only) Programmable input 01 PrPreAlarm ON / (read only) Presence detection pre-alarm ServiceTrap ON / (read only) Service hatch open Reserve ON / (read only) Outputs StgInSURV ON / (read only) Command lock entrance door StgInSSK ON / (read only) Command open entrance door StgInNSK ON / (read only) Command emergency close entrance door StgOut- SURV ON / (read only) Command lock eit door StgMid-SURV ON / (read only) Command lock middle door Reserve ON / (read only) StgOutSSK ON / (read only) Command open eit door StgMidSSK ON / (read only) Command open middle door Reserve ON / (read only) StgOutSOK ON / (read only) Command emergency open eit door StgMidSOK ON / (read only) Command emergency open middle door V4.0 32/ 45

33 Reserve ON / (read only) LedGreenIn ON / (read only) Green traffic light entrance door LedRedIn ON / (read only) Red traffic light entrance door Buzzer ON / (read only) Buzzer Light ON / (read only) Lighting Reserve ON / (read only) LedGreen- Out ON / (read only) Green traffic light eit door Led Green Mid ON / (read only) Green traffic light middle door Reserve ON / (read only) LedRedOut ON / (read only) Red traffic light eit door LedRedMid ON / (read only) Red traffic light middle door Reserve ON / (read only) FlashIn ON / (read only) Flashing light entrance side PictogramIn ON / (read only) Pictogram entrance side FlashOut ON / (read only) Flashing light eit side Reserve ON / (read only) Pictogram- Out ON / (read only) Pictogram eit side Reserve ON / (read only) Outputs BMS1-01 ON / BMS1-02 ON / BMS1-03 ON / BMS1-04 ON / (read only) BMS relay status BMS1-05 ON / BMS1-06 ON / BMS1-07 ON / BMS1-08 ON / V4.0 33/ 45

34 BMS2-01 ON / ON / (read only) BMS2-02 ON / (read only) BMS relay status ON / (read only) BMS2-03 ON / (read only) BMS relay status Reserve ON / (read only) BMS2-04 ON / (read only) BMS relay status Et.GateLeft- IN1 Et.GateLeft- IN2 Et.GateLeft- IN4 ON / (read only) BMS2-05 ON / (read only) BMS relay status Et.GateRight IN1 ON / (read only) BMS2-06 ON / (read only) BMS relay status Et.GateRight IN2 ON / (read only) BMS2-07 ON / (read only) BMS relay status Reserve ON / (read only) BMS8-08 ON / (read only) BMS relay status Et.GateRight IN4 ON / (read only) Inputs PrWallLeft ON / (read only) Light curtain left wall detection Reserve ON / (read only) PrWallRight ON / (read only) Light curtain right wall detection Reserve ON / (read only) PrCeiling ON / (read only) Light curtain ceiling detection Reserve ON / (read only) PrElsFloor ON / (read only) Light barrier floor detection V4.0 34/ 45

35 Reserve ON / (read only) PrElsCeiling ON / (read only) Light barrier ceiling detection Reserve ON / (read only) Reserve ON / (read only) ON / (read only) Command left wing gate open / close Reserve ON / (read only) Et.Gate1- Out1 Et.Gate1- Out2 ON / (read only) Command left wing gate open / close Voice3Busy ON / (read only) Voice module 3 (eit side) enabled Reserve ON / (read only) Au21 ON / (read only) Programmable input 21 Reserve ON / (read only) Voice1Busy ON / (read only) Voice module 1 (entrance side) enabled Reserve ON / (read only) ON / (read only) Light barrier floor detection wing gate Voice2Busy ON / (read only) Voice module 2 (tunnel) enabled PrPreAlarm ON / (read only) Presence detection pre-alarm Reserve ON / (read only) PrFloorEt ON / (read only) Light barrier floor detection wing gate PrPreAlarm ON / (read only) Presence detection pre-alarm Reserve ON / (read only) Au12 ON / (read only) Programmable input 12 ON / (read only) Motion detection pre-alarm Reserve ON / (read only) PrFloor Etended RadarPre- Alarm PreElsWide- Mid ON / (read only) Light barrier 2 corridor detection WIDE V4.0 35/ 45

36 ON / (read only) Command right wing gate open/close Reserve ON / (read only) PrElsWideIn ON / (read only) Light barrier 1 corridor detection WIDE Et.Gate2- Out1 Et.Gate2- Out2 ON / (read only) Command right wing gate open / close Inputs Voice1In1 ON / Voice module 1 message number Voice1In2 ON / Voice module 1 message number Voice1In3 ON / Voice module 1 message number Voice1In4 ON / Voice module 1 message number Voice1Start ON / Voice module 1 start Voice2In1 ON / Voice module 2 message number Voice2In2 ON / Voice module 2 message number Voice2In3 ON / Voice module 2 message number Voice2In4 ON / Voice module 2 message number Voice2Start ON / Voice module 2 start Voice3In1 ON / Voice module 3 message number Voice3In2 ON / Voice module 3 message number Voice3In3 ON / Voice module 3 message number Voice3In4 ON / Voice module 3 message number Voice3Start ON / Voice module 3 start Reserve ON / V4.0 36/ 45

37 INPUTS / OUTPUTS TRIPLE Inputs Triple 0 15 Reserve ON / (read only) PrElsOut ON / (read only) Counter light barrier eit door DoorOut- Open DoorOut- Close ON / (read only) Eit door open ON / (read only) Eit door closed Reserve ON / (read only) RadarOut ON / (read only) Motion detector eit door Reserve ON / (read only) Reserve ON / (read only) Reserve ON / (read only) PrWingOut ON / (read only) Swing area protection eit door Reserve ON / (read only) DoorOut- Locked ON / (read only) Eit door locked Reserve ON / (read only) AlarmStg- Out ON / (read only) Control alarm eit door Reserve ON / (read only) Reserve ON / (read only) Inputs Triple CamGoTri1 ON / (read only) Pass back detection 1 CamGoTri2 ON / (read only) Pass back detection 2 AC Power- Fail2 ON / (read only) Power supply monitoring Reserve ON / (read only) Reserve ON / (read only) V4.0 37/ 45

38 Reserve ON / (read only) Reserve ON / (read only) PrFloor2 ON / (read only) Floor detection light barrier PrVolumetric2 SwEmerg- Eit2 RadPre- Alarm2 Emerg- Closing2 Total- Opening2 ON / (read only) Volumetric monitoring sensor ON / (read only) Emergency open switch ON / (read only) Pre-alarm motion detector ON / (read only) Emergency closing ON / (read only) Total open Reserve ON / (read only) Service- Trap2 ON / (read only) Service hatch open Reserve ON / (read only) Outputs Triple Reserve ON / (read only) Reserve ON / (read only) Reserve ON / (read only) StgOut- SURV ON / (read only) Command lock eit door StgOutSSK ON / (read only) Command open eit door StgOutSOK ON / (read only) Command emergency open eit door Reserve ON / (read only) Reserve ON / (read only) Buzzer2 ON / (read only) Buzzer Light2 ON / (read only) Lighting V4.0 38/ 45

39 LEDGreen- Out ON / (read only) Green traffic light eit door LEDRedOut ON / (read only) Red traffic light eit door Reserve ON / (read only) Reserve ON / (read only) FlashOut ON / (read only) Flashing light eit side Pictogram- Out Inputs Triple ON / (read only) Pictogram eit side PrWallLeft2 ON / (read only) Light curtain left wall detection PrWall- Right2 ON / (read only) Light curtain right wall detection PrCeiling2 ON / (read only) Light curtain ceiling detection PrElsFloor2 ON / (read only) Light barrier floor detection PrEls- Ceiling2 ON / (read only) Light barrier ceiling detection Reserve ON / (read only) Reserve ON / (read only) Reserve ON / (read only) Au21 ON / (read only) Programmable input 21 Reserve ON / (read only) Reserve ON / (read only) Reserve ON / (read only) PrFloor - Etended PrPre- Alarm2 ON / (read only) (read only) Presence detection pre-alarm Reserve ON / (read only) CamGoTri3 ON / (read only) Pass back detection 3 CamGoTri4 ON / (read only) Pass back detection V4.0 39/ 45

40 SETTINGS LANGUAGE Language EN Select the language: EN = English, DE = German, FR = French Date and time Get settings Save settings Hour 0 23 (Integer) Value hour Minute 0 59 (Integer) Value minute Day 1 31 (Integer) Value day Month 1 12 (Integer) Value month Year (Integer) Value year TCP / IP Get settings Save settings IP1 10 (Integer) IP address byte 1 IP2 17 (Integer) IP address byte 2 IP3 10 (Integer) IP address byte 3 IP4 1 (Integer) IP address byte 4 Subnet1 255 (Integer) Subnet mask byte 1 Subnet2 255 (Integer) Subnet mask byte 2 Subnet3 255 (Integer) Subnet mask byte 3 Subnet4 0 (Integer) Subnet mask byte 4 Gatway1 0 (Integer) Gateway byte 1 Gatway2 0 (Integer) Gateway byte 2 Gatway3 0 (Integer) Gateway byte 3 Gatway4 0 (Integer) Gateway byte V4.0 40/ 45

41 RECORD MENU Sys parameters PStgType ST20 ST20 = STM20 ST16 = STG16 PPlcSlot5 = without input module Slot 5 ON = with input module Slot 5 PEtended- Version V2.0 V1.0 = Firmware Inde 001 V2.0 = Firmware Inde 006 Sys timer TSignal 10 (ds) Debounce time for light curtain signal TPassBack- Decision 20 (ds) Maimum closing time for entrance door in case of pass back until activating intrusion alarm. Otherwise wrong way alarm is set V4.0 41/ 45

42 Alarm list Alarm list Display symbols (eample) Display Code Description Date and time Alarm 90 General Technical alarm.. / :: Status display OK = status OK = confirm (reset) Alarm status Enabled = High Disabled = OK Alarm reset Not pressed NAK Pressed OK V4.0 42/ 45

43 Alarm list FlipFlow alarm list Code Source Description Message type 10 Entrance Door Control unit alarm Alarm 11 Entrance Door Open: PrEls ON Warning 12 Entrance Door Closed: PrEls ON Warning 13 Entrance Door Not open, not closed Warning 14 Entrance Door Doesn t open Warning 15 Entrance Door Doesn t close Warning 16 Entrance Door Open: PrWing ON Warning 17 Entrance Door Closed: PrWing ON Warning 20 Eit (Mid) Door Control unit alarm Alarm 21 Eit (Mid) Door Open: PrEls ON Warning 22 Eit (Mid) Door Closed: PrEls ON Warning 23 Eit (Mid) Door Not open, not closed Warning 24 Eit (Mid) Door Doesn t open Warning 25 Eit (Mid) Door Doesn t close Warning 26 Eit (Mid) Door Open: PrWing ON Warning 27 Eit (Mid) Door Closed: PrWing ON Warning 30 Eit Door Control unit alarm Alarm 31 Eit Door Open: PrEls ON Warning 32 Eit Door Closed: PrEls ON Warning 33 Eit Door Not open, not closed Warning 34 Eit Door Doesn t open Warning 35 Eit Door Doesn t close Warning 36 Eit Door Open: PrWing ON Warning 37 Eit Door Closed: PrWing ON Warning V4.0 43/ 45

44 Alarm list 6 Code Source Description Message type 40 Etended Gate 1 Control unit alarm Alarm 41 Etended Gate 2 Control unit alarm Alarm 42 Etended Gate Doesn t open Warning 43 Etended Gate Doesn t open Warning 44 Etended Gate PrFloor ON Warning 45 Etended Gate Unit disabled Info 50 Sensors Tunnel 1 Presence floor Warning 51 Sensors Tunnel 1 Presence els flor Warning 52 Sensors Tunnel 1 Presence ceiling Warning 53 Sensors Tunnel 1 Presence els ceiling Warning 54 Sensors Tunnel 1 Presence left wall Warning 55 Sensors Tunnel 1 Presence right wall Warning 56 Sensors Tunnel 1 Presence volumetric detection Warning 60 Sensors Tunnel 2 Presence floor Warning 61 Sensors Tunnel 2 Presence els flor Warning 62 Sensors Tunnel 2 Presence ceiling Warning 63 Sensors Tunnel 2 Presence els ceiling Warning 64 Sensors Tunnel 2 Presence left wall Warning 65 Sensors Tunnel 2 Presence right wall Warning 66 Sensors Tunnel 2 Presence volumetric detection Warning 70 CamGo Init-alarm Warning 80 Pass Back Cam 1 (tunnel1) Alarm V4.0 44/ 45

45 Alarm list 6 Code Source Description Message type 81 Pass Back Cam 2 (tunnel1) Alarm 84 Pass Back Cam 1 (tunnel2) Alarm 85 Pass Back Cam 2 (tunnel2) Alarm 86 Pass Back Cam 3 (tunnel2) Alarm 87 Pass Back Cam 4 (tunnel2) Alarm 88 Pass Back Pre-alarm Alarm 89 Pass Back Intrusion-alarm Alarm 90 General Technical alarm Alarm 91 General Material alarm Alarm 92 General RIO missing Alarm 93 General Sabotage Warning 94 General No-alarm switch Info 95 General Cleaning switch Info 96 General Emergency open 1 Info 97 General Emergency open 2 Info 98 General Total opening Info 99 General Emergency closing Info 100 General IO Et. missing Alarm V4.0 45/ 45

46 record your global partner for entrance solutions Contact ÎÎrecord UK limited Head Office: Unit D, 9 Watt Place Hamilton International Park Blantyre G72 0AH UK Central Office: Batley Business Centre Unit 40 Annee 2 Technology Drive Batley WF17 6ER UK Southern Office: 17 Invincible Road Farnborough GU14 7QU UK tel.: fa: info@recorduk.co.uk ÎÎrecord global eport agtatec ltd Allmendstrasse Fehraltorf Switzerland tel.: eport@record.global ÎÎHeadquarters agtatec ltd Allmendstrasse Fehraltorf Switzerland tel.: info@record.group your global partner for entrance solutions Subject to technical modifications Copyright agtatec ag n Manufacturer: agtatec ag Allmendstrasse Fehraltorf Switzerland

record.group User manual record FlipFlow Triple automatic door systems this is record! record your global partner for entrance solutions

record.group User manual record FlipFlow Triple automatic door systems this is record! record your global partner for entrance solutions record your global partner for entrance solutions User manual record FlipFlow Triple your global partner for entrance solutions record.group automatic door systems this is record! Table of contents Table

More information

FlipFlow. Exit Lane Breach Control. Creating Secure Environments. record your global partner for entrance solutions

FlipFlow. Exit Lane Breach Control. Creating Secure Environments. record your global partner for entrance solutions record your global partner for entrance solutions Exit Lane Breach Control Creating Secure Environments your global partner for entrance solutions FlipFlow Security and Safety Preventing unauthorised access

More information

STA 21. record STA 21. record system 20 technologies for light to medium-heavy applications. record your global partner for entrance solutions

STA 21. record STA 21. record system 20 technologies for light to medium-heavy applications. record your global partner for entrance solutions record record STA 21 record system 20 technologies for light to medium-heavy applications www.agta-record.com STA 21 www.agta-record.com STA 21 2 record STA 21 record system 20 technologies for light to

More information

record.group User manual DFA 127 IN automatic door systems this is record! record your global partner for entrance solutions

record.group User manual DFA 127 IN automatic door systems this is record! record your global partner for entrance solutions record your global partner for entrance solutions User manual DFA 127 IN automatic door systems this is record! your global partner for entrance solutions record.group Table of Contents Table of Contents

More information

DFA 127. record DFA 127 automatic drive system for swing doors. record your global partner for entrance solutions

DFA 127. record DFA 127 automatic drive system for swing doors. record your global partner for entrance solutions record your global partner for entrance solutions record DFA 127 automatic drive system for swing doors your global partner for entrance solutions DFA 127 your global partner for entrance solutions DFA

More information

Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS

Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS Orthos PIL-M02: Content > Background and requirements > Examples and dimensions > Personal security > Sensors for directional identification > Presence

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

record DFA 127 The silent, energy-saving automatic swing door operator

record DFA 127 The silent, energy-saving automatic swing door operator Drive technology for pedestrian entrances and industrial applications security centralised monitoring maintenance special solutions é record DFA 127 The silent, energy-saving automatic swing door operator

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

SmarTemp Control fx 2.0

SmarTemp Control fx 2.0 Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles

More information

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

SERIES 4000 AUTO GATE MANUAL

SERIES 4000 AUTO GATE MANUAL SERIES 4000 AUTO GATE MANUAL Website: www.turnstilesecurity.com Page 1 of 27 Table of Contents 1.0 Warranty... 4 2.0 Safety... 5 2.1 Designated Use... 5 2.2 Areas of Application... 5 2.3 Warning Notes...

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

DOCUMENTATION IPS640

DOCUMENTATION IPS640 DOCUMENTATION IPS640 TECHNICAL AND APPLICATION DESCRIPTION Authors: Nebojša Božič, Peter Hauner Last modification: 2017-01-25 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details,

More information

DOCUMENTATION IPS640

DOCUMENTATION IPS640 DOCUMENTATION IPS640 TECHNICAL AND APPLICATION DESCRIPTION Authors: Nebojša Božič, Peter Hauner Last modification: 2018-07-06 2001-2018 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details,

More information

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

BURGLAR ALARM PANEL BS-468/A

BURGLAR ALARM PANEL BS-468/A BURGLAR ALARM PANEL BS-468/A Contents 1. Description... 4 2. User instructions... 5 2.1. Basic operations... 5 Complete System... 5 Split System... 5 2.2. Armed system indication... 6 2.3. Advanced operations...

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

CONTROL DEVICE SLIDETRONIC HD

CONTROL DEVICE SLIDETRONIC HD CONTROL DEVICE SLIDETRONIC HD to control gravity self-closing fire gates Producer: Somati system s.r.o. Jihlavská 510/2c 664 41 Troubsko, okr.brno - venkov Tel.: 547 427 011 Fax: 547 427 013 E-mail: export@somati-system.cz

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

1. Functions of GPS locator ETLOC-30S 3

1. Functions of GPS locator ETLOC-30S 3 Contents 1. Functions of GPS locator ETLOC-30S 3 1.1 Direct view of the vehicle position on the map 3 1.2 Vehicle security 3 1.2.1 Vehicle protection 3 1.2.1.1 GPS protection 3 1.2.1.2 GPS higher level

More information

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector 307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

WiFi GSM APP Smart Home Security System

WiFi GSM APP Smart Home Security System User Manual WiFi GSM APP Smart Home Security System Tips: Please read through this user manual before installation so as to operate properly. Please keep well of the user manual for further reference.

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Manual# 1100334 User s Manual 200 Series DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel Rev. March 2012 User's Manual for the Marine Pro 200 Series ~~~ DCU 210 Diesel Engine Control Unit DCU

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 OPERATORS MANUAL AFP-300/400 INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02) 9899-4155

More information

Instructions manual. By-alarm. By-alarm Manager software

Instructions manual. By-alarm. By-alarm Manager software Instructions manual By-alarm By-alarm Manager software Index 1. Procedure for the complete programming of the By-alarm system 5 Operations to be carried out prior to the programming with By-Alarm Manager

More information

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19 OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers

More information

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual Document Number: 057-159 Author: Fady Atallah DSE94xx Configuration Suite PC Software Manual ISSUE 15 DSE94xx

More information

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT User manual ABB i-bus EIB Zone Terminal MT/S 4.12.1 Intelligent Installation System ABB STOTZ-KONTAKT 2 Contents Page 1 Device configuration..................................... 4 1.1 Introduction..........................................

More information

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Manual# 1100268 User s Manual DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3 Table of Content GENERAL INFORMATION... 3 ABOUT THIS MANUAL... 3 400 SERIES OVERVIEW... 3 Available Modules...

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) MRS752348-MUM Issued: 0/997 Version: F/23.6.2005 Data subject to change without notice COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) Contents. Introduction... 3. Features... 3.2 Application...

More information

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface INSTRUCTION MANUAL FI6000 Fire Alarm Interface Thank you for choosing another quality product from Amperes Electronics. FI6000 is a phase evacuation controller which can be integrated with various Amperes

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link - 1 Application Note Public Address Smart Safety Link PAVIRO and FPA configuration Bosch Security Systems Public Address Bosch Security Systems Public Address Application Note Smart Safety Link - PAVIRO

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

Ref.1067/032 Ref.1067/042

Ref.1067/032 Ref.1067/042 DS1067-033A Mod. 1067 LBT8631 BUS CONTROL PANEL 8/32 INPUTS Ref.1067/032 Ref.1067/042 USER MANUAL TABLE OF CONTENTS 1 PREFACE... 5 2 COMMAND DEVICES... 6 2.1 1067/021 DISPLAY KEYPAD... 6 2.2 ELECTRONIC

More information

Application description

Application description Application description Application description Hersteller KNX Touch Control Hager Displays Touch Displays ETS Touch Control Order number Product designation Application programme TP product SWDT03 WDT030

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0 IRIS Touch 400 & 600 Range Installation Manual Honeywell Galaxy Range Version 2.0 Table of Contents 1 System Overview... 4 2 IRIS Touch 440 & 640 PCB Layout... 5 3 Connection & Configuration for Honeywell

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS Firmware versions up to V2.0.X INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGCUIT2Protocol-IM-H57880 06/15 1/32 Contents Section I Introduction

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

RTO. User guide 05/

RTO. User guide 05/ RTO User guide Version: RT0 M&S (master & slave) Characteristics: Constant lighting, temperature regulation with a low inertia heating system. Building opening hour scheduler and presence detection. 05/2013

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

Diagnostics and Monitoring System WEB Tool 2. User Manual

Diagnostics and Monitoring System WEB Tool 2. User Manual Diagnostics and Monitoring System 2 (Translation of the original documentation) User Manual S/N: Valid from: 01.05.2012 Rev.: 2.0 2 Rev. 1.... 1 1.1 General information... 1 1.1.1 Equipment... 1 1.1.2

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

Use of the application program

Use of the application program Contents overview Use of the application program Use of the application program 1 1. Functional description 2 Switching on / off 2 Dimming brighter / darker 2 Dimming value (8 bit) 3 Status Switching (1

More information

Switch Mode Power Supplies

Switch Mode Power Supplies Switch Mode Power Supplies S8VK-X A New Standard in Preventative Maintenance The Connected Power Supply Switch Mode Power Supplies S8VK -X Production Site Innovation inspired by IoT OMRON aims to create

More information

Gunnebo SpeedStile BP. BA/EV Series. Bi-parting Speed Gate for Internal Installation

Gunnebo SpeedStile BP. BA/EV Series. Bi-parting Speed Gate for Internal Installation Gunnebo SpeedStile BP BA/EV Series Bi-parting Speed Gate for Internal Installation Bi-parting Speed Gate for Internal Installation Motorised Bi-parting wings Exclusive and timeless award winning design.

More information

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system. Page : 1 of 17. ELAUSYS JA-KNX KNX Interface for Jablotron alarm system User Manual Document history Version. Date Author Comment 1.00 24-JUN-2017 NDE First issue 1.01 14-NOV-2017 NDE Support for user

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Building Technologies. FDUL221 en Line tester operating instructions for electricians FDUL221 en Line tester operating instructions for electricians 1. Intended use The FDUL221 line tester is used to diagnose an addressed detector line in FDnet/C-NET. During diagnosis, the detector line

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

Xtralis VESDA LCD Programmer Quick Reference Guide

Xtralis VESDA LCD Programmer Quick Reference Guide Xtralis VESDA LCD Programmer Quick Guide Xtralis VESDA VLP Xtralis VESDA VLS Xtralis VESDA VLC Scope of this Manual This manual is to be used as a quick reference guide to perform the initial detector

More information

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Quick Start This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the button 'Inclusion Button' for one

More information

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1904 READ AND SAVE THESE INSTRUCTIONS BASIC-PLC CONTROLLER MANUAL For all Condair desiccant dryer with equipped with Basic- PLC valid from version: PLC-35/PLC-45 18.04.03 Dehumidification

More information

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY + USER S MANUAL 1.0 HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Technical Information Electric Slide-In Range JES8850BC* JES9900BC* JES9860BC* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

General Purpose IO Technical Manual

General Purpose IO Technical Manual General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope

More information

Advisor Advanced User Guide

Advisor Advanced User Guide Advisor Advanced User Guide P/N 1068996 (EN) REV G ISS 28AUG15 Copyright Trademarks and patents Manufacturer Version Certification 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved.

More information

ThermoControl 0 C - 10 C - 20 C - 30 C

ThermoControl 0 C - 10 C - 20 C - 30 C ThermoControl Product and Quality Reliability Alarm Functions & Documentation Global Monitoring 0 C - 10 C - 20 C - 30 C Global monitoring: global temperature measurement and real-time monitoring using

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations. MyNice Welcome to your Nice World The intelligent solution for the integrated management of the alarm system and of the home s automations. Home page Wi-Fi and GSM status and connected users System name

More information