Comfort and Light Controller Lonbox PZM4148
|
|
- Camron Watkins
- 5 years ago
- Views:
Transcription
1 Comfort and Light Controller Lonbox PZM4148
2 DIN or ready to go BOX
3 Decentralized Boxes Look for DIN hardware Find software Design boxes Produce boxes
4 Comfort and Light Controller PZM4148
5 The Lonbox PZM4148 solution Lonbox PZM4148 Solution Ready to go box from Prolon
6 Characteristics 1 Ready to go Box Terminals for all wires Supply for all external units Two complete Zones
7 Characteristics 2 LonWorks MIP design Software as LonMark Extra software and functions Build-In test functions
8 Benefits 1 Low design cost Low hardware cost Low or no production cost Lower cost for each zone Lower software cost
9 Benefits 2 Quickly project design Quickly production Quickly integration Component independence One software version, all projects
10 Profit Larger Contribution margin Finished in time Simple maintenance Ready for additional sale
11 Comfort and Light Controller PZM Vdc and 24Vac on/off Zone 1 Zone 2 Heat 0-10 Vdc and 24Vac on/off Cool 0-10 Vdc and 2 * 24Vac on/off Ventilation AC or DC motor 2 NO Relay with High Start Current and Vdc output M Comfort and Light Controller M Sunblind 2 Light and dimmer NO Relay PZM 4148 Light or load Analog/digital input Pushbuttons Analog/digital input Light sensor Digital input Movement detector Analog input Programmeable sensor type Temperature Sensor
12 LonMark
13 General purpose objects
14 Light Objects
15 Space Comfort objekterne nvohvactemp HVAC Temperature Sensor (1040) # 1 nviapplicmode nvicoolprslve nvicoolseslve nvienrgyhldof nviheatprslve nvioccsched nvioccsensor nvioutdoortmp nvisetpoint nvisetptoffst nvislave nvispacetemp nvivalveovrid nvocoolprimry nvocoolsecond nvoeffoccup nvoeffsetpt nvoheatcool nvoheatprimry nvosetpoint nvospacetemp nvounitstatus Space Comfort Controller (8500) # 1 nvilevel Heat Actuator # 1 nvilevel Cool Actuator # 1 nvohvactemp HVAC Temperature Sensor (1040) # 2 nviapplicmode nvicoolprslve nvicoolseslve nvienrgyhldof nviheatprslve nvioccsched nvioccsensor nvioutdoortmp nvisetpoint nvisetptoffst nvislave nvispacetemp nvivalveovrid nvocoolprimry nvocoolsecond nvoeffoccup nvoeffsetpt nvoheatcool nvoheatprimry nvosetpoint nvospacetemp nvounitstatus Space Comfort Controller (8500) # 2 nvilevel VAV Actuator # 1 nvilevel Heat Actuator # 2 nvilevel nvioccupancy nvispaceiqa nvoflowsetpoint Cool Actuator # 2 Indoor air quality controller # 1 nvilevel nvioccupancy nvispaceiqa nvoflowsetpoint VAV Actuator # 2 Indoor air quality controller # 2
16 Sunblind and Gateway Objects nviswitch nvosetting nviswitch nvosetting Switch to setting converter # 1 Switch to setting converter # 4 nviswitch nvosetting nviswitch nvosetting Switch to setting converter # 2 Switch to setting converter # 5 nviswitch nvosetting nviswitch nvosetting Switch to setting converter # 3 Switch to setting converter # 6
17 Digital and Analog objects
18 Zone Space Comfort Controller nvooccup Bevægelses detektor Occupancy Sensor nvosetptoffset nvivavvalue VAV Actuator Manuelt Setpunkt Setpoint Knob nvohvactemp HVAC Temperature Sensor Temperaturføler nvienergyholdoff nvioccschedule nvioccsensor nvioutdoortemp nvisetpoint nvisetptoffset nvispacetemp nvocoolprimary nvocoolsecondary nvoeffectoccup nvoeffectsetpt nvoheatcool nvoheatprimary nvosetpoint nvospacetemp nvounitstatus Space Comfort Controller nvivalvelevel1 Cool Actuator nvivalvelevel Heat Actuator
19 Indoor Air Quality
20 Sensor Occupancy and Space Comfort
21 Set-points and Space Comfort Cool, heat set points
22 Cool compensation Example With outdoor temperature -10 degrees the minimum heat will be 20% Configuration for minimum heat (UCPTminHeat) 40% low -20, 30% high 10, 0% 30% 20% 10% 0% Out door temperature
23 Minimum Cooling Minimum cool
24 Light with Occupancy and Manual
25 Constant Light, Manual and Occupancy
26 Light Master Slave Offset
27 Partition Wall Controller, Occupancy
28 Partition Wall Controller
29 Test LED 33.1 L 33.2 L 34.1 N 34.2 N 35.1 PE 35.2 PE V V 37.2 LUX 37.1 LUX 32.1 L L V V 31.1 L L V V 30.1 L L V 41.2 PIR V 41.1 PIR 29.1 N 29.2 N V V 28.1 PE 28.2 PE V V 1.1 M1 1.2 M TEMPb 45.1 TEMPb V V 47.1 DIM V 44.1 TEMPa 44.2 TEMPa 4.1 M2 4.2 M2 5.1 N 5.2 N 6.1 PE 6.2 PE 3.2 PE 3.1 PE 47.2 DIM V 49.2 DIM DIM1 7.1 M3 7.2 M LON1A 50.1 LON1A 8.1 N 8.2 N 51.2 LON1B 51.1 LON1B 52.2 LON2A 52.1 LON2A 9.1 PE 9.2 PE V 53.2 LON2B V 53.1 LON2B Vdc Vdc 55.2 V+dc 55.1 V+dc Vac Vac 13.1 L/+dc /0Vdc 2.2 N 13.2 L/+dc /0Vdc 57.2 V1+ac 58.2 V2+ac Vdc 57.1 V1+ac 58.1 V2+ac Vdc 15.1 N/ N/ C+dc 60.1 C+dc Vac Vac 2.1 N 16.1 Ma 16.2 Ma 62.2 C+ac 62.1 C+ac 17.1 Mb 17.2 Mb Vdc Vdc 18.1 N/ N/ H+dc Vac 64.1 H+dc Vac 66.2 H+ac 66.1 H+ac ZONE2 ZONE1 on V V V 68.2 IN V 68.1 IN Type No. Power symbol
30 Build-In Point test Zone 2 Zone 1
31 Sensor Occupancy test
32 Sensor LUX sensor test
33 Terminal blocks TEMPb V 47.2 DIM V 49.2 DIM V 37.1 LUX V V V 41.1 PIR V V V 68.1 IN V V 44.1 TEMPa 45.1 TEMPb V 47.1 DIM V 49.1 DIM LON1A 51.2 LON1B 52.2 LON2A 53.2 LON2B Vdc 55.2 V+dc Vac 57.2 V1+ac 58.2 V2+ac Vdc 60.2 C+dc Vac 62.2 C+ac Vdc 64.2 H+dc Vac 66.2 H+ac ZONE LON1A 51.1 LON1B 52.1 LON2A 53.1 LON2B Vdc 55.1 V+dc Vac 57.1 V1+ac 58.1 V2+ac Vdc 60.1 C+dc Vac 62.1 C+ac Vdc 64.1 H+dc Vac 66.1 H+ac V 37.2 LUX V V V 41.2 PIR V V V 68.2 IN V V 44.2 TEMPa ZONE1 on Type No.
34 Terminal blocks 2 Fuse ZONE 2 ZONE 1 230VAC MAIN SUPPLY 230VAC LIGHT SUPPLY LIGHT 1 OUT HIGH INRUSH LIGHT 2 OUT HIGH INRUSH LIGHT 3 OUT 230VAC / 24VDC SUNBLIND INPUT 230VAC / 24VDC SUNBLIND OUTPUT
35 Questions
Product Data. Voyager TM Rooftop air conditioner or heat pump unit with LonTalk communication interface for Voyager TM rooftop controls
Voyager TM Rooftop air conditioner or heat pump unit with LonTalk communication interface for Voyager TM rooftop controls LonTalk Communication Interface April 2002 Overview Each Voyager rooftop air conditioner
More informationCorp L (Supersedes 02/2008)
Service Literature Corp. 0627L5 0608 (Supersedes 02/2008) IMC LonTalk Module GENERAL The IMC LonTalk module allows communication between the Lennox IMC M17 (version 5.02 and higher) or M18 controller and
More informationApplications Application is compatible with Q1 Hardware. Compatible with Heat Pump Unit equipment up to 4 stages of cooling or heating, analog or floating-point valves or digital stages, discharge pressure/variable
More informationApplications Application is compatible with Q1 Hardware. Compatible with Fan Coil Unit equipment up to 4 stages of cooling or heating, analog or floating-point valves or digital stages, discharge pressure/variable
More informationTracer Controls. Tracer ZN.520: Unit Controller for Terminal Products TD-PRM001-EN
Tracer Controls Tracer ZN.520: Unit Controller for Terminal Products TD-PRM001-EN 2 TD-PRM001-EN General Tracer ZN.520 unit controller is a microprocessor-based direct digital controller that controls
More informationGOLD_E_LonWorks_140611
FUNCTIONAL PROFILE: GOLDen GATE Lonworks FTT-10, TBLZ-3-1-1-41, Version 1.00 GOLD RX/PX/CX/SD, GENERATION E Applicable to program version 1.10 and newer versions Specifications are subject to alteration
More informationSensors and Detectors
12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental
More informationDocument # R00
Viconics VT7200 Series PIR Ready Zoning Thermostats General The VT7200 series PIR Ready low-voltage microprocessor-based zoning thermostats have been specifically designed to control either 0-10Vdc, staged,
More informationFUNCTIONAL PROFILE: Gateway Lonworks FTT-10, TBLZ , Version 1.00 COMPACT Sizes 02-03, Program Version 1.00
FUNCTIONAL PROFILE: Gateway Lonworks FTT-10, TBLZ-4-1-1-41, Version 1.00 COMPACT Sizes 02-03, Program Version 1.00 Specifications are subject to alteration without notice. www.swegon.com General This document
More informationFUNCTIONAL PROFILE: GOLDen GATE Lonworks FTT-10, TBLZ , Version 5.00 GOLD Sizes 04-80, Version C, Program Version 5.00
FUNCTIONAL PROFILE: GOLDen GATE Lonworks FTT-10, TBLZ-3-1-1-41, Version 5.00 GOLD Sizes 04-80, Version C, Program Version 5.00 Specifications are subject to alteration without notice. www.swegon.com 1
More informationControls LonMark DDC VAV Controller
Introduction This LonMark certified controller uses the Space Comfort Controller (SCC) profile to exchange information over a LonTalk network. Networks with LonMark certified controllers provide the latest
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationPSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor
TECHNICAL SPECIFICATIONS PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor Overview Quad Element PIR sensor 0-10V configurable output: set to 0% (OFF)*, 10%, 25% or 50% dimming Photocell for ambient light
More informationDigital Addressable Lighting Interface
Digital Addressable Lighting Interface Who started DALI? It is supported by major manufacturers of ballasts Initially promoted by: And now including: BAG, Erco, Insta, Johnson controls, Magnetek, FCS lighting,
More informationRF-KNX / TP-KNX MEDIA COUPLER CO KNX 002
RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 1 General Description RF-KNX / TP-KNX media coupler. Bidirectional Gateway between
More informationPassive infrared ceiling sensor
Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room,
More informationDevices for Special Applications
Overview AP 2/11 UP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 UP 2 AP 2 Control Integrated constant light level control 1-channel 3-channel -- -- -- 1-channel -- -- 1-channel -- 1-channel
More informationRoom Temperature Controller
3 331 Synco 100 Room Temperature Controller with 2 outputs DC 0 RLA162 Room temperature controller for basic ventilation, air conditioning and heating plants Compact design with 2 analog control outputs
More informationLED Compatible Daylight Harvesting and Motion Sensor System
MADE IN GERMANY BY OUR FRIENDS AT EPV DH1 Technical Data MAX. MOUNTING HEIGHT AMBIENT TEMP. CURRENT CONSUMPTION 5m 0 50 C (Indoor) max. 15mA at 24V SWITCHING CAPACITY Occupancy Signal: Max. Dimming Status
More informationcontrol sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals
control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004
More informationDistrict heating controller for two heating circuits and d.h.w. according to Siemens specifications:
4 319 2984 0 G2384en en Installation Instructions District heating controller for two heating circuits and d.h.w. RVD240 Installation Place of installation In a dry room, e.g. in the heat exchanger room
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationKnürr RMS Compact II. Knürr RMS Compact II 2.81
Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81 Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions
More informationDescription of the application programme for KNX occupancy detectors version 3.1
Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs
More informationSkydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter.
36 AC Triac Series Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter. The Triac dimmer with AC input and AC output
More informationHeating Controller for 2 heating circuits, d.h.w. and boiler, communicating
2 477 Heating Controller for 2 heating circuits, dhw and boiler, communicating RVP330 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationUP 258E11 OPTISENS OFFICE
Product and functional description The UP 258E11 is a presence/motion detector with integrated 2-point light control. The UP 258E11 device communicates via KNX/EIB with actuators or other KNX devices.
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationLEVEL SWITCH NV-2T v2.1 Installation instructions Order. no: 13169
LEVEL SWITCH v2.1 Installation instructions Order. no: 13169 Description The is intended for dynamic lighting control using dimmable light fittings with control, in order to reduce the lighting time for
More informationRVL471 Heating and Domestic Hot Water Controller Basic Documentation
RVL471 Heating and Domestic Hot Water Controller Basic Documentation Edition: 2.2 Controller series: C CE1P2524E 23.10.2002 Siemens Building Technologies HVAC Products 2/118 HVAC Products 23.10.2002 Contents
More informationRamp It Up VAV Ramps and Controller Possiblities
Head Office Neptronic 400 Lebeau Blvd. Montreal, Quebec, Canada H4N R6 Tel.: (54) -4 Fax: (54) -6 Toll Free: -800-6-08 Ramp It Up VAV Ramps and Controller Possiblities The following article explains the
More informationRVP310. Heating Controller. Building Technologies HVAC Products
2 475 Heating Controller RVP310 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationDigital Precise Air Control - DPAC
Digital Precise Air Control - DPAC Mode Enable Sensor Options The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during Occupied operation. The following options
More information0701 CO Light, HVAC, Monitoring, Brightness
Using the application program Communication objects Product range: Product type: Manufacturer: Name: Order No.: Phys. sensors presence detector Siemens UP 258/21 presence detector 5WG1 258-2AB21 Functional
More informationDESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B
Wall mount/indoor transmitter for temperature, relative humidity and two dry contact inputs. Dual dry-contact inputs allow integration of light switches, motion and occupancy sensors in any combination.
More informationSynco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.
Synco-GAMMA Application Guide Hotel buildings Answers for infrastructure. Enhanced comfort and energy efficiency in hotels with Synco and GAMMA building systems Requirements Single source Types of integration
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationKNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX
2CKA001473B8668 23.02.2017 KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX Busch-Presence detector mini KNX 6131/20-xxx-500 Busch-Presence detector mini, premium, KNX 6131/21-xxx-500
More informationPSC-ID-x-CM Series Ceiling Mount Occupancy Sensor
TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-038 08/16 FEATURES SPECIFICATION > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) >
More informationONX908PIT-V1-S1-F1/B Modulating Digital Thermostat
ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat Installation and operation instructions The ONX908PIT-V1-S1-F1 modulating digital thermostats are designed to provide Proportional-Integral (PI) modulating
More informationRVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating
2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room
More informationCU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS
GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual
More informationIN2 Lighting Control Devices
Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals
More informationB.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.
B.E.G. LUXOMAT net KNX intelligent building automation using sensors from B.E.G. Effective energy saving in buildings 2 KNX sensors from B.E.G. are specially developed for the creation of economical solutions
More informationLighting Management Solutions
Lighting Management Solutions Switch sensors & KNX ed. 2012 PUTTING A STOP TO ENERGY WASTE Putting a stop to energy waste CONTENTS Our vision...p3 Why implement Lighting Management?...p4 Lighting Management
More informationGE Lighting. Lighting Controls. DALI Digital Lighting Controls
GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable
More informationApplications i.cas typical application is control of compressed air systems. It eliminates energy waste, provides state of the art compressor sequencing, load matching, independent user zones with isolation
More informationHydronic & HVAC Control Systems
tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informatione.control Function overview
e.control Function overview 2012/2013 e.control TM - unlimited functionality Due to the significance of automation for the energy efficiency, economy and ergonomics of a building, a new planning approach
More informationProduct Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution
Product Comparison Guide EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution Table of contents EnOcean 868MHz devices Lighting applications....6-10 Occupancy applications....10-12
More informationRVL481. Heating Controller. including d.h.w. heating
2 541 Heating Controller including d.h.w. heating RVL481 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control with
More information2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC
2CDC 508 179 D0201 24.11.2017 Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC Table of contents Table of contents 1 s on the instruction manual... 12 2 Safety... 13 2.1 Information and
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationTHERMA FUSER SIDEWALL LINEAR VAV DIFFUSER
THE ELW INTEROPERABLE THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER FORM 56.1 REV 0707 SPECIFICALLY DESIGNED FOR INTEROPERABILITY The ELW provides more information about what s happening in the space than
More informationHoneywell ENERGY SAVINGS KIT
ENERGY SAVINGS KIT 1. Application The Honeywell Energy Savings Kit reduces energy consumption by sending a dry contact signal to a Honeywell thermostat to change its set-point (increase in cooling mode)
More informationESL-IC Smart Room Control
Smart Room Control Agenda Room Control fundamentals and evolution Challenges The Smart Room Control approach Benefits Market applications Typical Configurations Summary Room Control System Fundamentals
More informationLEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no
LEVEL SWITCH v1. Installation instructions Order no. 13181 E-no. 13 6 81 Control that uses a light sensor Presence Power regulating up to two hours No presence Low level Blue knob1% Rest No presence Completely
More informationTebis application software
5 Tebis application software STCC530E 2-channel presence detector 360 A faire Product reference Description TP device RF devices TCC530E Bi-zone presence detector TCC530E Output module: Dimmer Loads connected
More informationT7984 A,B,C Electronic Modulating Control Thermostats
T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in
More informatione-controls INTERNATIONAL EDITION PRODUCTS AND SOLUTIONS Energy efficiency and control in buildings Nº 4 electronic intelligent controls, s.l.
e-controls electronic intelligent controls, s.l. INTERNATIONAL EDITION PRODUCTS AND SOLUTIONS Energy efficiency and control in buildings Nº 4 1 Table of Contents COMPANY PRESENTATION 4 MOST RELEVANT PROJECTS
More informationPredator Controller Hardware Family
Predator Controller Hardware Family Figure1: Predator Controller Only. Figure 2: Predator VAV Actuator. The LONMARK certified configurable Predator Controller provides direct digital control of a variety
More informationInstallation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN
Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN April 2005 CNT-SVX07C-EN Tracer ZN521 Zone Controller Installation
More informationTrios Training Manual
Trios Training Manual Version 1.2, June 2002 TRIOS training-manual 1. 2 1 1. TRIOS SYSTEM INTRODUCTION... 2 The Trios Concept... 2 Trios Multi-functionality... 2 Trios Flexibility... 2 Trios Simplicity...
More informationRVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products
2 478 Heating Controller for 2 heating circuits, d.h.w. and boiler RVP331 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated flow
More informationB.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR
B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR GB Contents 1. GENERAL 1 1.1 KNX bus basics 1 1.2. Overview 1 1.3 Symbols 1 2. OCCUPANCY DETECTOR BASICS 2-3 2.1 Introduction 2 2.2 Motion detection with the B.E.G.
More informationETO 2 - Controller for ice and snow melting
ETO 2 - Controller for ice and snow melting Advantages Simple adjustment knob with two functions Illuminated display where you can easily see the temperature status and other values Controls both pumps
More informationProduct Comparison Guide
Product Comparison Guide EnOcean 902MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution Control Performance Energy savings Better building management Table of contents EnOcean
More informationRVL470. Heating Controller. Use. Functions. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationRVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning
G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More information1. Product description
1. Product description Technical data sheet clima DL-110 Available inputs and outputs The clima DL-110 is a universal room controller. It is suitable for controlling static heating/cooling systems (like
More informationA. This Section includes the following lighting control devices:
SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More informationMotion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels
MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load
More informationPower Supply Display Module PSDM. Installation and Operation Manual
Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious
More informationProduct Specifications Dialog Room Controller* (*patent pending)
1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,
More informationEast Central College
SECTION 260923 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER
Technical Data Sheet SP-4000-DC GUARDIAN INFINITY PRESSURIZATION ONITOR AND DUAL CONTROLLER Description The Guardian Infinity is a true differential space pressure measurement system engineered to combine
More informationApplication Manual LT-6617 Rev. 1 July 2017
Application Manual LT-6617 Rev. 1 July 2017 Table of Contents 1.0 Frequently Asked Questions 4 2.0 OpenBAS Wiring Guidelines 6 3.0 Wiring 9 4.0 Glossary 11 3 1.0 Frequently Asked Questions 1.1 What is
More informationINSTALLATION, BALANCING & MAINTENANCE. Table Of Contents INSTALLATION INSTRUCTIONS...2 CONNECTING WIRING...2
THERMA-FUSER ELW - DDC ITEROPERABLE SIDEWALL LIEAR VAV DIFFUSER ISTALLATIO, BALACIG & MAITEACE FORM 56.2 REV 0703 Table Of Contents ISTALLATIO ISTRUCTIOS...2 COECTIG WIRIG...2 ETWORK CREATIO AD COMMISSIOIG
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationTechnology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2
Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared
More informationFeature Summary. I. System
I. System A. Supports up to 60 VAV HVAC Units 1. Each HVAC Unit Can Support up to 59 VAV Boxes 2. Constant Volume Units Can Be Integrated With VAV Units 3. System Can Support Over 3000 Controllers B. Fill-in
More informationTri-level Control Sensor
Daylight Monitoring Photocell Advance TM One-Key Commissioning Ambient daylight threshold oop in oop out Tri-level Control Sensor HC038V HCD038 Detached inear Version with Remote Control Applications Occupancy
More information7800 SERIES RM7888A Relay Module
7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically
More informationRVL480. Heating Controller
2 540 Heating Controller RVL480 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control, boiler temperature control
More information0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom
Viconics VT7350 Series PIR Ready Fan-coil Controllers General The VT7350 series are PIR Ready low-voltage microprocessor-based fan-coil controllers. Models are available controlling single speed and multi-speed
More informationApplications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements
INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6
More informationLG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls
LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls 1 Article I. General Section 1.01 Section 1.02 Section 1.03 System Description Quality Assurance Storage and Handling Article
More informationBetter Design, Better Control, Better Systems.
Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More informationSensors Explained AUTOMATION
Sensors Explained Sensors Explained: Our range of PIR sensors and microwave presence detectors are designed to reduce the amount of time lighting is left on unnecessarily, for example if an area is unoccupied
More informationDESCRIPTION MODEL 1205/1205HA NOTE
Integrated Temperature, Relative Humidity and Dew Point Transmitter. Housed in a rugged stainless steel body offering excellent corrosion protection. RH Accuracy at 25 C:: Model 1205 2% typical / 3% maximum;
More informationInstallation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4
Installation Guide Tracer ZN523 Zone Controller Contents Introduction About this manual 3 Controller description 4 Typical network architecture 5 Hardware inspection 6 Mounting and wiring ZN523 mounting
More information