4.2. Characteristics. handset

Size: px
Start display at page:

Download "4.2. Characteristics. handset"

Transcription

1 COMMUNICATION Kommunikation

2 FIREFIGHTERS COMMUNICATION SYSTEM EN handset firecom freecom The fire-fighters communication system enables a two-way communication between the car of the fire-fighters lift, the fire-fighters access level and the machine room of the lift. The system consists of three components: - handset (handset/exchange) - fire-com (hands-free speakerphone/fire-fighters speakerphone) - free-com (hands-free speakerphone/car speakerphone) Fire-fighters operation is initiated via the fire-fighters switch. Power supply 24 V DC (± 15 %) No. of participants 1 handset, 2 hands-free speakerphones Network extension max. 250 m with 0.5 mm² max. 500 m with 1 mm² Lines high, low, UB,, line Operating voltage min. 12 V of the components Current consumption of the system without luminaries Installation closed-circuit status approx. 40 ma operating status approx 150 ma communication status approx 250 ma to the controller 2 machine room of fire-fighters lift 0 1 handset USV 24 V 2 S2 Mae fire-fighters switch firecom freecom fire-fighters access level i-indicator enforcing button speech acknowledgement S1 Ma fire-fighters key switch 0 1 call button 4.2 Only to be used in combination with Styles and Components wg and grille wg (water-protected). For additional information regarding EN please refer to Norms. car of fire-fighters lift

3 Firefighters Communic. FIREFIGHTERS COMMUNICATION SYSTEM EN handset (handset/exchange) Function Fixing Connection technology The handset consists of: the handset, the wall holder and the flexible cable. On the outside of the handset of the display, is where the LED and the keypad are placed. The loudspeaker and the microphone are set inside. The handset takes over the internal exchange functions and serves as exchange. This exchange has special functions like e. g. check-calling all components and control over establishment and termination of connections. wall holder 0.1 mm²... 1 mm² Current consumption (per device) Temperature range Compliance approx. 7 ma ma (stand-by) approx. 40 ma (active) max. 60 ma (communication) 0 C C (2h) EN Wall holder Ø ø 4 Connection not occupied not occupied not occupied 24 V - 30 V DC JPR1 HIGH HIGH LOW LOW UB UB LINE LINE JPR2 Fixing accessories provided on site 4.3

4 FIREFIGHTERS COMMUNICATION SYSTEM EN Fire-com (hands-free speakerphone/fire-fighters speakerphone) Fixing Connection technology The hands-free speakerphone fire-com serves to participate in an interactive 2-way communication. According to EN the water- and penetrationprotected fire-com is placed behind the faceplate of the fire-fighters fixture at the fire-fighters access level. Besides an ESD housing the fire-com is equipped with a microphone and a loudspeaker with volume control. welding studs M3 x 8 (faceplate fixing) 0.1 mm²... 1 mm² Current consumption approx. 7 ma ma (stand-by) (per device) approx. 45 ma 50 ma (active) approx. 80 ma 90 ma (communication) Temperature range 0 C C (2 h) Compliance EN Rear view welding stud M3 x Connection DIP switch i-indicator communication indicator enforcing button space for cables H1 H2 T1 volume i-indicator (H1) communication indicator (H2) enforcing button (T1) LINE UB LOW HIGH fire-fighters switch (S2) ( ) ø44 ø Only to be used in combination with Styles and Components wg and grille wg (water-protected). Please order fixing accessories separately.

5 Firefighters Communic. FIREFIGHTERS COMMUNICATION SYSTEM EN Free-com (hands-free speakerphone/car speakerphone) Fixing Connection technology The hands-free speakerphone free-com serves to participate in an interactive 2-way communication. According to EN the water- and penetrationprotected free-com is placed behind the faceplate of the car fixture or on the car roof. Besides an ESD housing the free-com is equipped with a microphone and a loudspeaker with volume control. welding studs M3 x 8 (faceplate fixing) 0.1 mm²... 1 mm² Current consumption approx. 7 ma ma (stand-by) (per device) approx ma (active) approx ma (communication) Temperature range 0 C C (2 h) Compliance EN Rear view welding stud M3 x 8 Connection DIP switch call button space for cables H1 H2 T1 volume call released (H1) call accepted (H2) call button (T1) LINE UB LOW HIGH ø44 ø Only to be used in combination with Styles and Components wg and grille wg (water-protected). Please order fixing accessories separately. 4.5

6 FPM 32 Communication System HA 32 FPM 32 is a modular communication system for establishment of communications to the different areas of a lift installation: Car, porter s lodge, machine room. It consists of two components, the HA 32 (handset) and the LMK 32 (hands-free speakerphone). Via a 5-wire bus, the power supply and the speech signals as well as all calls and emergency calls are transmitted. Emergency calls from the hands-free speakerphones are signalised at all related handsets optically and acoustically. Power supply 12 V V DC No. of participants max. 16 handsets HA 32 max. 16 hands-free speakerphones LMK 32 Network extension max. 500 m bei 0.5 mm² max m bei 1 mm² Lines high, low, UB,, line LMK 32 Installation Z N1 N2 N3 F1 F2 F3 F4 F5 4.6

7 FPM 32 FPM 32 HA 32 (Handset) Function Fixing Connection technology On the outside of the handset, a display an LED and a keypad are placed. The loudspeaker and the microphone are set on the inside. The handset HA 32 can call all participants within the system as well as accept incoming calls and emergency calls. One handset HA 32 is configured as exchange and takes over internal exchange functions like e. g. check-calling all components and control over establishment and termination of connections. wall holder 0.1 mm²... 1 mm² Current consumption approx. 5 ma 7 ma (stand-by) (per device) approx. 40 ma (active) max. 60 ma (communication) Temperature range 0 C +40 C (2 h) Compliance EN Wall holder Ø ø 4 Connection not occupied not occupied not occupied 24 V - 30 V DC JPR1 HIGH HIGH LOW LOW UB UB LINE LINE JPR2 Fixing accessories provided on site 4.7

8 FPM 32 LMK 32 (Hands-Free Speakerphone) Fixing Connection technology The hands-free speakerphone LMK 32 is a component of the communication system FPM 32. It is installed in the lift car. In addition to the emergency call button two further indicators can be connected to the LMK 32 as external elements. The first indicator acknowledges the emergency call, the second indicator signalises the establishment of a communication. Besides an ESD housing the LMK 32 is equipped with a microphone and a loudspeaker with volume control. welding studs M3 x 8 (faceplate fixing) 0.1 mm²... 1 mm² Current consumption approx. 6 ma 8 ma (stand-by) (per device) approx. 40 ma (active) approx. 100 ma (communication) Temperature range 0 C C (2 h) Rear view Connection welding stud M3 x 8 DIP switch 104 space for cables volume HIGH 8 LOW 7 UB 6 5 LINE 4 emergency call button 3 emergency call accepted 2 emergency call released 1 Please order fixing accessories separately. Grille design depending on fixture design As pictogram indicator according to EN all illuminated fields and Style 42 indicators from SCHAEFER are suited.

9 F-H uni F-H2 uni F-H uni / F-H2 uni Communication System handset Daten Power supply No. of participants Network extension F-H uni and F-H2 uni are simple analogue communication systems for establishment of communications. The system consists of a handset for the machine room or the porter s lodge and a hands-free speakerphone LMK which is installed in the lift car. The simple variant F-H uni consists of one handset and one hands-free speakerphone LMK. With the variant F-H2 uni a second handset is included. 6 V V DC max. 2 handsets max. 1 hands-free speakerphone LMK max. 500 m with 0.5 mm² max m with 1 mm² LMK Installation F-H uni Installation F-H2 uni L: loudspeaker (+) B: common earth (-) 0: not occupied Z: not occupied U: microphone (+) L: loudspeaker (+) B: common earth (-) 0: not occupied Z: not occupied U: microphone (+) P L 2 4 P L 2 L B O Z U 6 7 L B O Z U L B O Z U L B O Z U car 1 8 P L NO 7 NO C 8 C potentiometer P = volume HEARING L = Lvolume SPEAKING V DC emergency call button potentiometer P = volume HEARING L = Lvolume SPEAKING V DC emergency call button 4.9

10 F-H uni / F-H2 uni Handset Function The handset is equipped with a loudspeaker and a microphone on the inside. By lifting of the handset a communication will be established to the car immediately. This communication will be terminated by hanging up the handset. If two handsets are used (F-H2 uni), both of them serve for establishing a communication with the car. 50 ø Fixing accessories provided on site

11 F-H uni F-H2 uni F-H uni / F-H2 uni LMK (Loudspeaker-Microphone Combination) Daten Fixing Connection technology The loudspeaker-microphone combination LMK serves as counterpart to the handset. It is installed behind the faceplate of the car fixture. welding studs M3 x 8 (faceplate fixing) 0.1 mm²... 1 mm² Connection U Z O B L L: loudspeaker (+) B: common earth (-) 0: not occupied Z: not occupied U: microphone (+) 39 welding stud M3 x 8 mounting plate L B O Z U 105 ø Please order fixing accessories separately. Grille design depending on fixture design 4.11

12 EASY ALARM Remote Emergency Call System basic device The remote emergency call system Easy-Alarm consists of the basic device Easy-Alarm EA-8-DPX_ and the hands-free speakerphone EA-LMK70A-DCDC. The automatic dialling and announcing device Easy-Alarm is connected to an analogue telephone line. The system is available in three variants: hands-free speakerphone Easy-Alarm Elevator (EA-8-DPX) Easy-Alarm Elevator PLUS (EA-8-DPXN) alarm upon contact of the emergency call button establishment of the hands-free communication after acceptance of the emergency call storage of max. 9 emergency call numbers which are dialled consecutively cancellation of the emergency call with change of the door contact status (prevention of misuse) monitoring of technical errors option for connection of pictograms according to EN implemented cyclic connection test power supply 11 V 27 V DC closed-circuit current approx. 60 ma includes all features of Easy-Alarm Elevator connection to further analogue telephone lines dial-in in stages with common use of the exchange line with telephone/modem power supply 11 V 27 V DC closed-circuit current approx. 60 ma Easy-Alarm Elevator includes all features of Easy-Alarm Elevator Machine Room includes a telephone in the machine room (EA-8-DPXM) power supply 11 V 27 V DC closed-circuit current approx. 80 ma Accessories pictograms according to EN EN For additional information regarding EN please refer to Norms As pictogram indicator according to EN all illuminated fields and Style 42 indicators from SCHAEFER are suited.

13 Easy Alarm EASY ALARM EA-LMK70A-DCDC (Loudspeaker-Microphone Combination) Daten Fixing Connection technology The hands-free speakerphone EA-LMK70A-DCDC serves as loudspeaker-microphone combination in the car fixture. It is equipped with a connection to the power supply of the system and a connection for the emergency call button. It is also possible to connect the technical alarm and/or the pictograms according to EN welding studs M3 x 8 (faceplate fixing) 0.1 mm²... 1 mm² Current consumption EA-LMK70A-DCDC with basic device EA-8-DPX U = 12 V I closed circuit = 70 ma I operation = 330 ma U = 24 V I closed circuit = 40 ma I operation = 200 ma EA-LMK70A-DCDC with basic device EA-8-DPXM U = 12 V I closed circuit = 90 ma I operation = 330 ma U = 24 V I closed circuit = 50 ma I operation = 200 ma Temperature range -30 C C (2 h) 21.6 welding stud M3 x space for cables Please order fixing accessories separately. Grille design depending on fixture design 4.13

14 EASY ALARM Connection car roof RJ45 8/8 option: prevention of misuse 4 8 telephone line RJ11 6/4 -> wire end sleeves car fixture emergency call button 1 potential-free NO-contact VIN power supply 11 V V DC - + optional pictograms according to EN (yellow) (green) bulb 1 bulb 2 S3 option: technical alarm If bulb 1 and/or bulb 2 are connected, the power supply (VIN) must be done via an accumulator. For protection of the accumulator we recommend using the LOW CURRENT devices of the Style 42 by SCHAEFER (U = 3 V 30 V DC / I = 2 ma). 42 pictogram according to EN emergency call accepted pictogram according to EN emergency call released MA 42 P LC RA 42 LC 4.14

Firefighter Lifts 81-72

Firefighter Lifts 81-72 Firefighter Lifts FIREFIGHTER LIFTS Car and Landing Elements in the cabin Elements on the firefighter access level Car fixture (IPX3) Indicator fixture (IPX3) Norm conform displays DMD 30/35/50, LCD, LED

More information

EasyAlarm ELEVATOR LEITRONIC AG

EasyAlarm ELEVATOR LEITRONIC AG LEITRONIC AG Swiss Security Systems ELEVATOR EMERGENCY DIALLER BROCHURE EasyAlarm ELEVATOR Independent elevator emergency call by Swiss market leader can be installed / operated by any elevator company

More information

User guide Fire brigade communication system EN 81-72

User guide Fire brigade communication system EN 81-72 User guide Fire brigade communication system EN 81-72 SCHAEFER GmbH Winterlinger Straße 4 72488 Sigmaringen Germany Telephone +49 7571 722-0 Fax +49 7571 722-98 info@ws-schaefer.de www.ws-schaefer.de SCHAEFER

More information

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems 4923 Table of contents Overview... 2 2 Applications... 3 2. Door-phone... 3 2.. Wiring... 3 2.2 Alarm dialler... 4 2.2. Wiring... 4 3 Mechanical fitting... 5 3. Retrofit solutions to existing elevators...

More information

LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR

LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR Code: 0221 Isue: Issue: 7/2017 11 / 2014 Start-up Program calling numbers 5.1 Write down numbers 1 Announcement 2 Announcement 3 Announcement 4 Announcement

More information

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX LEITRONIC AG Swiss Security Systems ELEVATOR EMERGENCY DIALLER EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX Issue: 18 August 011 1. Door phone (EXICALL EN70) EN81-70 emergency button Center> 90cm (

More information

AVCOM System Installation Instructions

AVCOM System Installation Instructions AVCOM System Installation Instructions Index 1) AVCOM EN-1 System Drawings - AVCOM EN1 System.. Page 1 - AVCOM EN1 with 2COP.. Page 2 - AVCOM EN1 FF System.. Page 3 -AVCOM EN1 Evacuation System Page 4

More information

User instructions EasyAlarm CONTROL

User instructions EasyAlarm CONTROL LEITRONIC AG Swiss Security Systems TELEMONITORING / TELECONTROLLING SYSTEM User instructions EasyAlarm CONTROL Interface-Modul Potential free relay switch: 10..230V AC or DC AC-switch: max. 2A / 230V

More information

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker

More information

OPEN THE DOOR TO INNOVATION. 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift.

OPEN THE DOOR TO INNOVATION. 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift. OPEN THE DOOR TO INNOVATION 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift. For 25 years 2N has been on the forefront of access control and telecommunications. We take care to stay

More information

Basic Installation Manual

Basic Installation Manual SAR SAR-V.7 Program or Higher Alarm Equipment for Lifts Basic Installation Manual in HIDRA System controllers Revision 0 (EN) NOTES FROM THE MANUFACTURER Carlos Silva SA shall not be responsible for any

More information

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages ELECTRONIC ENGINEERING LTD. Voice Board Runner 4/8,PowerWave 4/8/16 &, Elite64 Add-on Board For Storing Recorded Voice Messages And listen-in. Installation and Programming Guide. P/N 7101372 Rev. C V.K

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Norstar. Doorphone User Guide

Norstar. Doorphone User Guide Norstar Doorphone User Guide Published by Nortel (Northern Telecom) on behalf of British Telecommunications PLC. All possible care has been taken in the preparation of this publication, but British Telecommunications

More information

Tunstall Vi+ User Guide

Tunstall Vi+ User Guide Tunstall Vi+ User Guide Your Tunstall Vi home unit The Tunstall Vi home unit is connected to the mains power supply and your telephone line. It enables you to generate a call for help when and if you need

More information

SafeLine SL6 THE NEXT GENERATION OF

SafeLine SL6 THE NEXT GENERATION OF Lift emergency telephones SafeLine SL6 THE NEXT GENERATION OF LIFT Emergency telephone systems SafeLine SL6 The complete lift emergency telephone and fire communication system in accordance with EN81-28,

More information

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

HIDRA CRONO Controller

HIDRA CRONO Controller HIDRA CRONO Controller SAR pluscom Alarm equipment for lifts Installation guide ENGLISH DC83501Q00 *DC83501Q00* Release 2b NOTE FROM THE MANUFACTURER Carlos Silva SA shall not be responsible for any claims

More information

Memcom + Emergency Telephone

Memcom + Emergency Telephone Memcom + Emergency Telephone Installation Guide Ref No. 453 901AU (GB) Version 4 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based

More information

Functional Door Entry System. Specification

Functional Door Entry System. Specification Functional Door Entry System 1 Planit Security Contracts Limited policy is one of continual improvement. The company reserves the right at all times to amend s without prior notification Technical Support

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual Emergency Call Box 2100-986DA 2100-986DAI Made in the USA 2 Year Warranty N56W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 www.rathcommunications.com RP85000986DA

More information

HELPY QUICK-TL GSM INTL

HELPY QUICK-TL GSM INTL Alarm system for elevators HELPY QUICK-TL GSM INTL QUICK GUIDE 04/02/16 DESCRIPTION A B C D E F G H I L M N O Connector for external LEDs Connector for built-in loudspeaker Built-in loudspeaker Connector

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

ELECTRICAL COMPONENTS REMOTE LIFT ALARM

ELECTRICAL COMPONENTS REMOTE LIFT ALARM ELECTRICAL COMPONENTS REMOTE LIFT ALARM Scalable remote lift alarm Line-TEL-compatible PTSN GSM VOIP Open protocols Compliant with decree 674 of 07/05/12 Immune to line variations Usage flexibility and

More information

MK9 series CarePhone. Installers Mauual

MK9 series CarePhone. Installers Mauual MK9 series CarePhone Installers Mauual 1 Please ensure that the last thing you do before leaving a User with an alarm is to make a test call through to the Monitoring Centre and speak to the Operator.

More information

Your Lifeline Vi+ home unit. Your MyAmie pendant

Your Lifeline Vi+ home unit. Your MyAmie pendant User Guide Your Lifeline Vi+ home unit The Lifeline Vi+ home unit is connected to the mains power supply and your telephone line. It enables you to generate a call for help when you need it by immediately

More information

Careline Anna Careline GSM

Careline Anna Careline GSM Careline Anna / Careline GSM Programming and installation manual List of contents 1 Introduction... 3 1.1 General description of Careline Anna/GSM... 3 1.2 General description of Tx4 alarm transmitter...

More information

Digital Door Entry System. Specification

Digital Door Entry System. Specification Digital Door Entry System 2 Planit Security Contracts Limited policy is one of continual improvement. The company reserves the right at all times to amend s without prior notification Technical Support

More information

Products compliant with the following standards and regulations: EN81/70, EN 81/28 and EN 81/72. Lead-free manufacturing. Reduced energy consumption

Products compliant with the following standards and regulations: EN81/70, EN 81/28 and EN 81/72. Lead-free manufacturing. Reduced energy consumption Remote Lift Alarm In order to improve communication in lifts, SODIMAS (Europe s leading independent lift manufacturer) is joining with SAFELINE (Leading telephone manufacturer in Scandinavia with more

More information

EC II GSM SE User Manual

EC II GSM SE User Manual EC II GSM SE User Manual 1 Table of contents 1 TABLE OF CONTENTS...2 2 NOTES AND DISCLAIMER...5 3 COPYRIGHT...5 3.1 Description of goods... Fehler! Textmarke nicht definiert. 3.2 Warranty...5 3.3 Updates...5

More information

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc. Operation Instruction VARIODYN D1 Comprio 798666.HO.GB0 07.2013 / AA GB Technical changes reserved. 2013 Honeywell International Inc. Intended use This product may only be used for the applications outlined

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

Lifeline Vi Clever, not complicated

Lifeline Vi Clever, not complicated Solution Sheet Clever, not complicated The is Tunstall s sixth generation home unit and sets the benchmark in the development of telecare solutions. It s the most technically advanced, flexible and simple

More information

Commend Columns. Security and Communication. Help and Information Points for people in need of assistance. Doors, Gates and Entrances

Commend Columns. Security and Communication. Help and Information Points for people in need of assistance. Doors, Gates and Entrances Coend Columns Security and Counication Perfect speech intelligibility A wide field of applications Vandal resistant Weatherproof Camera, Display, and more... Induction loop for hearing aid users Customizable

More information

Specialists in communications for the elevator industry

Specialists in communications for the elevator industry Specialists in communications for the elevator industry CATALOGUE 2017-2018 MERak - 1 Index of Contents MERak: Safety first MERak R&D MERak devices and EN 81-28 standard EMERGENCY TELEPHONES MEP2L Land

More information

Installation and user guide

Installation and user guide Installation and user guide D5307023A www.tunstallap.com Contents What s in the box? 3 The Connect+ 4 Front view 4 Back view 4 End view 4 Installation advice 5 Quick start guide 6/9 Intruder monitoring

More information

ANEP BOX TA + LIFT REMOTE ALARM

ANEP BOX TA + LIFT REMOTE ALARM ANEP BOX TA + LIFT REMOTE ALARM UPGRADABLE MULTI-LIFT PHONE AND INTERCOM SYSTEM www.anepstore.com TABLE OF CONTENTS 1 - GENERAL Page 5 1.1 - Description 1.2 - Recommendations 1.3 - Technical characteristics

More information

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL

More information

l 02-April-2010 For INSTANT CARE

l 02-April-2010 For INSTANT CARE l 02-April-2010 For INSTANT CARE Table of Contents 1. Application Overview 1 1.1. Identifying The Parts 1 1.2. The Power Supply 3 1.3. Line Capture 3 1.4. Line Failure Detection 4 1.5. How to install the

More information

EXICALL EN70MR EXICALL EN70-ATEX (upright version EXICALL EN70MR) (horizontal version EXICALL EN70MR)

EXICALL EN70MR EXICALL EN70-ATEX (upright version EXICALL EN70MR) (horizontal version EXICALL EN70MR) Use Instruction EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX Order-No. Order-No. Order-No. Order-No. 121.5102 (upright version EXICALL EN70) 121.5103 (horizontal version EXICALL EN70) 121.5104 (upright

More information

Interrogator 200 Audio Verification Module (AVM)

Interrogator 200 Audio Verification Module (AVM) Interrogator 200 Audio Verification Module (AVM) Document Number: 466-1153 Rev. B July 1996 Audio Verification Module Use a maximum of 500 feet of cable for all speakers and microphones. For example, if

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

PHOTOELECTRIC AMPLIFIER SERIES

PHOTOELECTRIC AMPLIFIER SERIES PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has

More information

ADE Gen4. Speech Dialler Engineering Information. Description. Features

ADE Gen4. Speech Dialler Engineering Information. Description. Features ADE Gen4 Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The

More information

SI120 Guarto Easy I. Alarm system. Fire & Security Products

SI120 Guarto Easy I. Alarm system. Fire & Security Products Alarm system SI120 Guarto Easy I Central alarm control unit with integrated communicator Simple to program Simple and reliable to operate Flexible Extensive communications Simple to install Alarm receiving

More information

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS ASTRO-PA/GA System EN 54-16 SISTEMA QUALITÀ CERTIFICATO ISO 9001 ISO 9001 CERTIFIED SYSTEM QUALITY F I T R E S.p.A. 20142 MILANO ITALIA via Valsolda, 15 tel.: +39.02.8959.01 fax: +39.02.8959.0400 e-mail:

More information

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Programming the Vi+ using a Series Telephone. Tunstall Vi+ Tunstall Vi+ Programming the Vi+ using a SeriesTelephone Your Vi+ Page 2 Ver 1 4/24/2015 Programming a telecare sensor to the Vi+ Telecare sensors with plug and play functionality can be programmed to

More information

AD1000EN-1R configured to operate as a DG1000

AD1000EN-1R configured to operate as a DG1000 AD1000EN-1R configured to operate as a DG1000 Install the Main Unit on top of the lift car and mount the Microphone in the COP. Mount the Plastic speaker box so the speaker holes align up with some holes

More information

Emergency/Help Point Analog Telephones & Correctional Analog Telephones

Emergency/Help Point Analog Telephones & Correctional Analog Telephones G U A R D I A N T E L E C O M Product and Services Guide Emergency/Help Point Analog Telephones & Correctional Analog Telephones Meeting the critical demands of public safety and operational security,

More information

! "! # Please read these installation and operating instructions completely and carefully before starting.

! ! # Please read these installation and operating instructions completely and carefully before starting. ! "! # $% Please read these installation and operating instructions completely and carefully before starting. File name:3009405d Revised,20/10/2008 Copyright, July 2004 The Armstrong Monitoring Corporation

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

TELEMERGENCY 750C USER MANUAL SIMPLE AUTOMATIC SYSTEM PREPARES YOUR HOME FOR ANY EMERGENCY. Consumer Helpline

TELEMERGENCY 750C USER MANUAL SIMPLE AUTOMATIC SYSTEM PREPARES YOUR HOME FOR ANY EMERGENCY. Consumer Helpline TM CHECKING THE TELEPHONE NUMBERS ENTERED FOR LIMITED NINETY-DAY WARRANTY This product is warranted by Telemergency, Ltd. against manufacturing defects in material and workmanship under normal use for

More information

Pre-Installation Requirements:

Pre-Installation Requirements: AlphaRefuge 2100 Series (V3) Area of Refuge and Rescue Assistance system Installation, Use and Wiring Instructions Pre-Installation Requirements: 120V Power Determine Communication: 1. Dedicated analog

More information

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA

More information

USER & INSTALLATION GUIDE

USER & INSTALLATION GUIDE Reach At Home Alarm Unit Touch Personal Pendant USER & INSTALLATION GUIDE www.tynetec.co.uk SECTION 1 USER INSTRUCTIONS Section Topic Page 1.1 Important Information 3 1.2 Unpacking the Reach At Home Alarm

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

NON-MONITORED EMERGENCY CALL SYSTEMS

NON-MONITORED EMERGENCY CALL SYSTEMS NON-MONITORED EMERGENCY CALL SYSTEMS A non-monitored emergency call system includes a pendant and a control box or phone which is connected to the telephone network (via landline or mobile network). When

More information

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS. ANEP BOX - TA EMERGENCY TELEPHONE FOR LIFTS EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS www.anepstore.com SUMMARY 1 - TECHNICAL CHARACTERISTICS Page 4 1.1 - Technical characteristics 1.2 - Machine

More information

ISDN LOOP BACK TESTER

ISDN LOOP BACK TESTER ISDN LOOP BACK TESTER MODEL MC-9044 SERIAL/ITEM 533/nnn OPERATING AND INSTALLATION MANUAL Issue 10, 1999 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY

More information

HELPY CONTROLLER QUICK GUIDE

HELPY CONTROLLER QUICK GUIDE Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY CONTROLLER QUICK GUIDE 05/04/2019 DESCRIPTION Autodialer specifically designed for installation on elevator controller.

More information

Emergency, Correctional & Institutional

Emergency, Correctional & Institutional G U A R D I A N T E L E C O M Product and Services Guide Sections 7 8 9 Emergency, Correctional & Institutional Analog Telephones Meeting the critical demands of public safety, operational security, ADA

More information

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79 IEC 60849 Electroacoustic EMERGENCY WARNING SYSTEM for a maximum of system security 79 EMERGENCY WARNING SYSTEM VARES Rear view ESC-006 A Input speaker lines 1-6 (from amplifiers) Output speaker lines

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation TYDOM 5 GSM domotics transmitter ) Présentation. Presentation Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions of the R&TTE Directive

More information

Laboratory Refrigerator/Deep Freezer TC 802

Laboratory Refrigerator/Deep Freezer TC 802 External Dimension: B = 600 mm D = 615 mm H = 2000 mm Inside Dimension: Useful space on top Useful space at the bottom B = 440 mm B = 431 mm D = 435 mm D = 435 mm H = 1105 mm H = 597 mm Capacity: 254 l

More information

CONTENTS. (User s Manual)

CONTENTS. (User s Manual) CONTENTS (User s Manual) 1. Foreword & Main Features & Brief introduction of the Product 2. Understanding of Alarm Host 3. Specifications 4. Type and definition of Defense Line 5. Programming the alarm

More information

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

OIL FILM DETECTOR (Flame-proof Version) SODL-1600 OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.

More information

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use GSM Smart Home Alarm Apparatus [99+4 defense zones] Instruction for Use Table of content Ⅰ. Introduction to the system... 2 Ⅱ. Introduction to function... 2 Ⅲ. System composition and use method... 3 Ⅳ.

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

Elemec3. Networked Public Address and General Alarm System (PA/GA)

Elemec3. Networked Public Address and General Alarm System (PA/GA) Elemec3 Networked Public Address and General Alarm System (PA/GA) Multiple combined single, N+1 and A/B architectures supported on a single network Seamless connection to and from VoIP telephones, amplified

More information

System solutions for every lift. Everywhere. Lift Emergency Call Systems

System solutions for every lift. Everywhere. Lift Emergency Call Systems System solutions for every lift. Everywhere. Lift Emergency Call Systems Introduction Philip Schmersal, Executive Director of the Schmersal Group, and Dr. Andreas Hunscher, Managing Director of Böhnke

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 28 3111 DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Heat detectors.

More information

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS. ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS www.anepanywhere.com SUMMARY 1 - TECHNICAL CHARACTERISTICS Page 4 1.1 - Technical characteristics 1.2 - Machine room Intercom and fireman until functionnality

More information

NEO IP/GSM Technical Handbook

NEO IP/GSM Technical Handbook NEO IP/GSM Technical Handbook NE41 09002-02 v2.0 Copyright 2011 Neat Electronics AB Revision date: 2011-12-19 NEAT Electronics AB Varuvägen 2 SE-246 42 Löddeköpinge Sweden Phone: +46 46 70 70 65 Fax: +46

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

DESTINY OWNER S MANUAL

DESTINY OWNER S MANUAL DESTINY OWNER S MANUAL DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System. The DESTINY has been designed to provide you with a maximum level of security

More information

Alarm Clock. Pokyny. Bedienungsanleitung. Brugsvejledning. Instrucciones. Käyttöohje. Mode d emploi. Instructions. Οδηγίες. Használati utasítás

Alarm Clock. Pokyny. Bedienungsanleitung. Brugsvejledning. Instrucciones. Käyttöohje. Mode d emploi. Instructions. Οδηγίες. Használati utasítás Alarm Clock Οδηγίες Használati utasítás Manuale d Uso Gebruiksaanwijzing Bruksanvisning Instrukcja obslugi DE DK ES FI FR GB Uputstvo za upotrebu RS Instruções GR Instructions HU Mode d emploi IT Käyttöohje

More information

Chromatographic Air circulated Refrigerator, two-door TC 603

Chromatographic Air circulated Refrigerator, two-door TC 603 External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:

More information

ADVENT xt WARDEN CALL SYSTEM V2.0 OPERATORS MANUAL

ADVENT xt WARDEN CALL SYSTEM V2.0 OPERATORS MANUAL ADVENT xt WARDEN CALL SYSTEM V2.0 OPERATORS MANUAL KIRK 4020/4040 DECT TELEPHONES WITH A PANASONIC 308 PBX Tynetec operate a policy of continual product improvement. If any variation to the details contained

More information

CONVENTIONAL FIRE ALARM CONTROL PANEL

CONVENTIONAL FIRE ALARM CONTROL PANEL CONVENTIONAL FIRE ALARM CONTROL PANEL 1PM2 Series Features Description 1PM2 The 1PM2 is a conventional fire alarm panel with a stylish wall-mount design supplied in 10 to 60 zone formats. All detector

More information

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01 DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL 800-6006V1 12/01 System Overview General Information Control Panel Detection Devices You have made a wise decision to protect your family and property

More information

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd. TITLE SLIDE FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR Doc. No: 32-0009-01 OPTICAL BEAM SMOKE DETECTORS This training material provides information to assist the Fire System Designer and Installer in

More information

Safety is individual! Flexible alarm dialler bébétel / EasyAlarm LEITRONIC AG. Baby monitorin Home security Personal security Technical alarm

Safety is individual! Flexible alarm dialler bébétel / EasyAlarm LEITRONIC AG. Baby monitorin Home security Personal security Technical alarm LEITRNIC AG Safety is individual! Flexible alarm dialler bébétel / EasyAlarm Baby monitorin Home security Personal security Technical alarm Telealarm / Telecontrol Man down Elevator emergency At any time

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

AT60 AUTO DIALLER User Guide

AT60 AUTO DIALLER User Guide AT60 AUTO DIALLER User Guide Power on LED MIC Power on LED MIC 1 2 3 4 5 6 7 8 9 REC/PLAY 0 STORE M1 M2 M3 Table of Contents I. Overview 3 II. Installation 4 III. Initialize the Dialer 5 IV. Using the

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

TABLE OF CONTENTS. AlphaVision ML User manual Rev

TABLE OF CONTENTS. AlphaVision ML User manual Rev User manual TABLE OF CONTENTS Table of contents... 2 Introduction... 4 Purpose of this manual...4 General Guidelines...4 European norm and security Grade...5 Zones and sections of the AlphaVision ML control

More information

CONNECTION WITH TELEPHONE COMPANY FACILITIES TARIFF P.S.C.-Md.-No Verizon Maryland LLC Section 5 Original Page 1

CONNECTION WITH TELEPHONE COMPANY FACILITIES TARIFF P.S.C.-Md.-No Verizon Maryland LLC Section 5 Original Page 1 Original Page 1 TABLE OF CONTENTS Recording, Reproducing and Automatic Answering and Recording Equipment... 2 Alarm Sending Equipment (Alarm Coupler)... 3 Dictation Recording Equipment... 4 Public Address

More information

AUDIBLE SIGNALIZATION

AUDIBLE SIGNALIZATION 01 SIGNALIZATION AUDIBLE SIGNALIZATION PROGRAMMABLE ELECTRONIC MULTITONE SIRENS WITH TWO INPUTS Specially designed for marine application With two inputs where using each one, different tones and frequency

More information

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS SENSORS FOR X-AIRCONTROL ZONE MODULES AND OTHER EQUIPMENT Components for the measurement and

More information

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN 04.13.2017 1 MONTICELLO INTERIOR FINISHES PAINT MOULDING WALLS ACCENT DOORS DOOR TRIM/STAIRS

More information

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B Lifeline 400 user guide q6 18/2/04 10:56 am Page 2 Lifeline 400 installation and user guide Part Number D3707103B Lifeline 400 user guide q6 18/2/04 10:56 am Page 3 Contents Your Lifeline 400 P3-4 What

More information

Entero Voice Alarm system. User guide

Entero Voice Alarm system. User guide Entero Voice Alarm system. User guide The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation. 2 Table of Contents Introduction...

More information

Technical Manual. Tel

Technical Manual. Tel Technical Manual Cables & technical data... What is Secura?...3 530 room terminal...4 50 wireless alarm generator (pendant)...6 50 wireless alarm generator (bracelet)...6 50 wall module for bathroom pull

More information

Hazardous Area Telephone Model EP600

Hazardous Area Telephone Model EP600 R Industrial Communications Worldwide Hazardous Area Telephone SN#W GUARDIAN TELECOM INC. EP600 TELEPHONE TELEPHONE FOR USE IN LR65547 HAZARDOUS LOCATIONS CLASS I, DIVISION 2, GROUPS A, B, C, & D CLASS

More information

D45 System. Colour 7 handsfree indoor handset. Front view

D45 System. Colour 7 handsfree indoor handset. Front view D System Description D System indoor handsfree video handset with analogue LD LED backlit display. omplete door entry functions with alarms management. International standard SOS pushbutton and keyboard

More information