SNMP Solutions Cookbook By Bob Berry

Size: px
Start display at page:

Download "SNMP Solutions Cookbook By Bob Berry"

Transcription

1 Interfaces FSK PSK LAN Dial-up Service Channels Overheads Protocols ASCII TL1 DCM DCP E2 FX8800 Modbus TABS TBOS TRIP POP3 NTP Ping SNMP Teltrac X.25 NEC 21SV Badger Cordell Datalok Felix Granger Alphanumeric Paging SMTP TMonNet RTUs Legacy RTUs PBXs Battery Plants Switches Routers Microwave Radios SNMP Solutions Cookbook By Bob Berry Simple Solutions for Marketing SNMP-Based Alarm Monitoring Work in Your Network SNMP Devices (PBXs, Switches, Routers) TL1 Devices (PBXs, Switches, Routers) T/Mon NOC Local Alarm Master ASCII Devices (PBXs, Switches, Routers) DPS Telecom Remotes LAN / WAN TBOS Remotes SNMP Traps DCP/DCPf/DCPx Remotes Regional SNMP Manager Badger, Larse, NEC, and Other Legacy Remotes Version 1.0 Released February 22, We protect your network like your business depends on it TM

2 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) About the Author Bob Berry is the founder and CEO of DPS Telecom, a leading developer of integrated network alarm monitoring solutions. Bob's engineering skill and dedication to solving his clients' real-world problems has grown DPS from a small consulting firm to an Inc. 500 company. Copyright 2005 DPS Telecom All rights reserved, including the right to reproduce this white paper or portions thereof in any form without written permission from DPS Telecom. For information, please write to DPS Telecom 4955 E. Yale Ave., Fresno, CA Call: info@dpstele.com Printed in the U.S.A 2

3 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) What This White Paper Will Do for You The number one question clients ask about SNMP is How can I use SNMP to do this? where this is the alarm monitoring application they care about the most. You don t deploy a new kind of alarm monitoring for the fun of it. If you re thinking about deploying SNMP in your network, it s because you have specific problems you need to solve. This is the book with the specific answers to your specific questions a quick cookbook of solutions to show you how you can get your job done with SNMP. For each application, I ll show you how it works and what you can do with it. I m constantly looking for ways to improve DPS Telecom white papers. If the question most important to you isn t in this book, give me a call at Let me know what you want to know, and I ll make sure it s included in the next edition. Cheers! SNMP Solutions Create a MOM System Incorporated SNMP and Non-SNMP Network Elements Create a Local NOC for Local Visibility Within an SNMP Network Mediate Non-SNMP Alarms to SNMP Mediate SNMP Alarms to TL Filter Nuisance Alarms Mediate TBOS Alarms to SNMP Mediate Contact Closures Collected at Your Main Distribution Frame to SNMP Mediate Contact Closures and Analog Inputs to SNMP Monitor Using SNMP Over Dial-Up or Serial Transport Ping IP Elements and Receive SNMP Traps if a Device Fails or Goes Offline Send Alarm Notifications to Maintenance Personnel via Pager and Install Cost-Effective SNMP Monitoring for Small and Large Sites Full Specifications for Products Used in These Applications

4 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) Interfaces FSK PSK LAN Dial-up Service Channels Overheads Protocols ASCII TL1 DCM DCP E2 FX8800 Modbus TABS TBOS TRIP POP3 NTP Ping SNMP Teltrac X.25 NEC 21SV Badger Cordell Datalok Felix Granger Alphanumeric Paging SMTP TMonNet RTUs Legacy RTUs Create a MOM System Incorporating SNMP and Non-SNMP Network Elements Problem PBXs Battery Plants Switches Need to monitor both SNMP and non-snmp equipment. Need to consolidate monitoring of legacy and modern networks. Inherited mixed collection of mutually incompatible equipment from predecessors. Inherited incompatible alarm systems from merger/acquisition of another company. Solution T/Mon NOC consolidates all your equipment, regardless of protocol or manufacturer, to one platform, giving you a single-screen view of all your network equipment. T/Mon NOC supports over 20 different protocols, including SNMP, TL1, TABS, TBOS and many proprietary protocols. (For a full list, see Appendix). Because of its support for multiple protocols, T/Mon NOC can monitor hundreds of different devices. For every protocol it supports, T/Mon NOC supports every device that uses that protocol and you re not charged extra probe fees for supporting multiple devices. It doesn t matter what the size of your integration issue is. Whether you have a few incompatible systems, or you need to consolidate two entirely separate networks, T/Mon NOC will give you a seamless view of all your equipment. Routers Microwave Radios Fig. 1. With support for over 20 protocols, T/Mon NOC can monitor all your network equipment. 4

5 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) SNMP Devices (PBXs, Switches, Routers) TL1 Devices (PBXs, Switches, Routers) T/Mon NOC Local Alarm Master ASCII Devices (PBXs, Switches, Routers) LAN / WAN DPS Telecom Remotes TBOS Remotes SNMP Traps DCP/DCPf/DCPx Remotes Regional SNMP Manager Badger, Larse, NEC, and Other Legacy Remotes Fig. 2. T/Mon NOC can act as a local NOC that collects alarms from local remote sites and mediate all alarms to SNMP traps that are forwarded to the SNMP manager at the regional NOC. Create a Local NOC for Local Visibility Within an SNMP Network Problem Relying on a distant regional NOC for alarm notifications gives you limited visibility and prevents timely repairs of remote site problems ultimately increasing downtime and maintenance costs. Solution T/Mon NOC can serve as both an alarm collector and alarm forwarder. Alarms within your local area can be collected to your T/Mon NOC using any of T/Mon s supported input protocols. You have real-time visibility of all your equipment, giving you the power to proactively monitor your remote sites and correct problems early. While collecting alarms at the local level, the T/Mon NOC will simultaneously forward your alarms in SNMP (or in TL1, ASCII, TABS, TBOS or other output protocols) to your central regional NOC. From the regional NOC s point of view, it s no different than if the local alarms had been sent directly. Another advantage of this setup is that you can selectively filter which alarms will be forwarded to the regional NOC. You can have an alarm for everything you need to see locally, down to very granular detail, without overwhelming the regional NOC with a cascade of alarms. 5

6 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) Mediate Non-SNMP Alarms to SNMP Problem Need to monitor non-snmp equipment from your SNMP manager. Solution T/Mon NOC s alarm collecting and alarm forwarding capabilities combine to create a protocol mediation solution. T/Mon collects the alarms in their original protocol, mediates them to SNMP traps, and forwards the traps to your SNMP manager. Any alarm that T/Mon collects can be mediated to an SNMP trap. Once again, you can filter which alarms T/Mon forwards, so you only see the alarms you want to see. SNMP Devices SNMP Traps LAN / WAN TL1 Autonomous Messages TL1 Manager Fig. 3. T/Mon NOC can receive SNMP traps and mediate them to TL1 autonomous messages. Mediate SNMP Alarms to TL1 Problem Need to monitor SNMP equipment from your TL1 manager. Solution T/Mon NOC can also mediate alarms to any of its supported output protocols, including TL1. T/Mon NOC will collect alarms from SNMP devices or any other supported equipment and mediate the alarm inputs to TL1 autonomous messages, forwarded to your TL1 manager. 6

7 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) Transport Equipment (Microwave Radios, OC3, Cellular Switches, etc.) Power Supply Systems (Generators, Rectifiers, Battery-plants, etc.) IT Infrastructure (Switches, Routers, Servers, etc.) Environmental Alarms (Temperature, Humidity, Site Security, etc.) Nuisance Alarm Filtering: Alarm Qualification Silence Alarms Tag Alarms Send Unimportant Alarms Directly to History File Other Remote Devices Filter Nuisance Alarms Problem Fig. 4. T/Mon NOC gives you many ways to filter unimportant alarms. Alarm system reports every unimportant status alarm, conditioning users to ignore alarms. Solution T/Mon NOC offers several features to filter nuisance alarms: Alarm Qualification: if problems are self-correcting, you might not need to know about them. You can filter these alarms by using an alarm qualification time that sets how long the alarm condition must be in effect before an alarm is declared. Alarm Silencing: alarms that oscillate and create a lot of alarm activity can be silenced for a specified length of time. Alarm Tagging: oscillating alarms can also be tagged to stay silent until untagged. No Log: alarms that are simply not important do not even need to appear on the monitoring screen. The alarm report goes straight to the history file, where it is recorded and can be retrieved later for analysis, if necessary. 7

8 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) TBOS Site Equipment NetMediator T2S LAN / WAN Serial Interface All Alarm Data via SNMP SNMP Manager Mediate TBOS Alarms to SNMP Problem Need to monitor on-site TBOS equipment (such as microwave radios) from your SNMP manager. Solution The NetMediator T2S provides dedicated on-site protocol mediation of TBOS devices. The NetMediator mediates up to 8 displays of TBOS data to SNMP traps. Mediating TBOS to SNMP gives you much better visibility than the alternative, relying on vague, major/minor summary alarms. The TBOS data contains detailed alarm descriptions, allowing you to diagnose equipment problems accurately. The NetMediator is also an SNMP RTU with 32 discrete alarms, 8 analog alarms and 8 control relays. Mediate Contact Closures Collected at Your Main Distribution Frame to SNMP Problem Fig.5. The NetMediator mediates TBOS alarms to SNMP traps on-site. Collecting contact closure alarms from a main distribution frame ordinarily requires hours of tedious cross-connecting between a terminal block and an SNMP remote telemetry unit. Fig. 6 The Remote Alarm Block 176N Solution The Remote Alarm Block 176N combines the functions of a terminal block and an SNMP RTU, providing easy conversion of contact closures to SNMP traps right at your main distribution frame. The RAB is a compact alarm block that mounts directly to your MDF, or to the wall if space is at a premium. The wires at the distribution frame are connected directly to the Remote Alarm Block s wire-wrap terminals and the only thing that comes out is one Ethernet cable that connects directly to your LAN and your SNMP manager. 8

9 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) Environmental Alarms (Temperature, Humidity, Site Security, etc.) NetGuardian 832A SNMP RTU Transport Equipment (Microwave Radios, OC3, Cellular Switches, etc.) Power Supply Systems (Generators, Rectifiers, Battery-plants, etc.) LAN / WAN SNMP Traps SNMP Manager Fig. 7. The NetGuardian 832A mediates discrete and analog alarms from remote site infrastructure equipment to SNMP traps. Mediate Contact Closures and Analog Inputs to SNMP Problem Need to monitor basic infrastructure (power supplies, facility alarms, temperature sensors and environmental alarms, etc.) from your SNMP manager. Solution The NetGuardian 832A remote telemetry unit mediates standard alarm in like contact closures and analog voltages to SNMP traps. All NetGuardian inputs can be mediated to SNMP traps but you can select to not send a trap for each individual alarm, so you can filter out any unimportant stuff. The analog inputs send traps for four thresholds, plus the SNMP manager can retrieve live actual readings from analog inputs by issuing a GET command. SET commands issued to the NetGuardian will activate the control relays, for turning on-site equipment on and off, locking and unlocking doors, etc. The NetGuardian can report to up to three SNMP managers at different IP addresses simultaneously, which makes it great for filtering alarms to different departments. The NetGuardian can also report simultaneously to T/Mon NOC. 9

10 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) Remote Site Without LAN Access Secondary Dial-up Connection PPP Server NetGuardian 832A Primary LAN Connection LAN / WAN SNMP Manager Alarm Collection Fig. 8. The NetGuardian will transport SNMP traps over dial-up or serial connection to a PPP server that interfaces with your LAN and SNMP manager. Monitor Using SNMP Over Dial-Up or Serial Transport Problem Need to monitor your network from your SNMP manager, but LAN access is not available at all your sites. Solution The standard NetGuardian 832A comes with an internal dial-up modem for backup transport. The NetGuardian is also available with optional support for RS-232, RS-422/485, 202 modem, 212 modem, FSK modem or PSK modem. The NetGuardian can transmit SNMP traps over dial-up or supported serial transport to a PPP server, which in turn connects via LAN to your SNMP manager. The NetGuardian also provides a migration path for converting sites to LAN transport. Installing a NetGuardian now will provide immediate SNMP support over existing transport; when LAN access is installed at the site, you only have to switch the NetGuardian to LAN transport and you don t have to install a new RTU. You can either turn down to dial-up or serial connection or keep it as a secondary backup data path. 10

11 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) IP 1 IP 2 IP 3 IP 4 IP 5 Constant ping of up to 32 IP addresses Alarm: IP 8 does not reply IP 6 SNMP Trap IP 7 IP 8 (Not functioning) SNMP Manager IP 32 Ping IP Elements and Receive SNMP Traps if a Device Fails or Goes Offline Problem Need to monitor online status of IP elements from your SNMP manager. Solution Both T/Mon NOC and the NetGuardian 832A have ping alarm functionality. Either unit will ping IP elements and send an SNMP trap to your SNMP manager if a network element does not respond to the ping. Which unit you should choose for this application depends on the scale of your needs. The NetGuardian can ping up to 32 IP addresses; T/Mon NOC can ping up to 960 IP addresses. Send Alarm Notifications to Maintenance Personnel via Pager and Problem Fig. 9. The NetGuardian can generate SNMP traps to alert you of IP device offlines and failures. Need 24/7 monitoring, but you can t afford a 24/7 manned NOC Solution T/Mon NOC comes standard with everything you need for 24-hour pager and notification. Paging and take network alarm monitoring out of the NOC to wherever you are your car, your remote sites, and even your home. 11

12 SNMP Solutions Cookbook DPS Telecom 4955 East Yale Avenue, Fresno, CA (800) Fax (559) You ll have total assurance that you ll be notified if problems happen at any time. You can keep your field techs out in the field, dramatically reducing windshield time. notifications even create an automatic alarm history record. Alarms can be acknowledged or tagged by two-way paging or from your cell phone. T/Mon NOC s automatic escalation ensures that you ll be notified if a tech doesn t acknowledge a page. The NetGuardian 832A also supports pager and notifications perfect for monitoring small networks without investing a lot of manpower. Install Cost-Effective SNMP Monitoring for Small and Large Sites Problem One-size-fits-all RTUs don t scale to the needs of large or small sites, leaving you with the options of paying for more alarm capacity than you need, installing insufficient alarm capacity or buying multiple units to cover one site.. Solution The NetGuardian 832A, NetGuardian 216 and NetGuardian 480 provide SNMP RTU capabilities, scaled to the needs of small, medium and large sites. The NetGuardian 832A provides 32 discrete alarms, 32 ping alarms, 8 analog alarms, 8 control relays, and 8 serial reach-through ports. A powerful all-purpose RTU, the NetGuardian 832A has all the tools you need to manage your remote site. For extra-large alarm capacity, the NetGuardian 832A can be augmented with 1 3 NetGuardian Expansion units, which raise the NetGuardian s alarm capacity to 80, 128 or 176 discrete alarm points. The NetGuardian 216 provides 16 discrete alarms, 2 analog alarms, 2 controls, and 1 serial reachthrough port. The NetGuardian 216 provides cost-effective alarm monitoring for small sites such as remote huts, collocation racks or enclosed cabinets. With the NetGuardian 216, you can afford to deploy alarm monitoring at every site in your network. The NetGuardian 480 provides 80 discrete alarms and 4 controls. The NetGuardian 480 offers enough alarm capacity to cover an entire site, saving you the cost of buying multiple units and giving you the most economical cost per alarm point. 12

13 DPS Telecom Product Data Sheet Your Partners in Network Alarm Monitoring T/Mon NOC What You Can Do with T/Mon NOC: Monitor alarms in 25 protocols, including ASCII, Badger, Cordell, DCM, DCP, DCPf, DCPx, DCM, E2A, Larse, Modbus, NEC, Pulsecom, SNMP, TABS, TBOS and TL1 Know the status of your network with 100% certainty. Send pager and notifications to maintenance staff 24/7 Mediate alarms to your existing master or MOM Field-proven system that is 100% guaranteed to work for you Advanced monitoring features for your real-world needs Support for quick turnup and lifetime maintenance Smooth migration to advanced monitoring, built on your existing monitoring equipment T/Mon NOC Overview T/Mon NOC is a multi-protocol, multifunction alarm manager that collects alarms from all your equipment, regardless of manufacturer or protocol, eliminating the need for specialized terminals. With T/Mon NOC, you can: Monitor alarms in 25 standard, legacy and proprietary protocols. Mediate alarm data to different protocols. Forward alarm data to other masters. Display the status of your entire network on one screen. Send pager and alarm notifications to multiple users automatically. Present network status and alarm information to multiple users connected via LAN, dial-up or serial port. Control remote site equipment manually or automatically in response to alarm inputs. Administer a centralized configuration database for your whole network. Maintain alarm history logs and create reports of alarm events. 13

14 Swappable Port Interface Cartridges Internal Modem Port Cartridge Extractor Printer Parallel Port Keyboard Port COM Port & Video Out T/Mon NOC Specifications Dimensions: 10.5" (6 RU) H x 17" W x 14" D Mounting: 19" or 23" rack Power Input: Dual 48 VDC or 110 VAC (depending on ordering options) Fuse: Two 2-Amp GMT fuses Operating Temperature: 32 to 95 F (0 to 36 C) Operating Humidity: 0% to 95% (non-condensing) Modem: 56K baud internal modem (for dial-up console access) LAN Interface: 10/100 BaseT Polling Ports: 24 user-selectable ports Polling Interfaces: RS-232, RS422/485, 202 modem, 33.6K modem, FSK modem, PSK modem T/Access COM Port: 1 Processor: 2.4 GHz Intel Pentium 4 Hard Drive: 40GB (7200 RPM) Slots: 6 PCI, 1 AGP Fans: 2 internal Removable Storage: 1.44 floppy disk drive, CD drive Visual Display: Front-panel LCD, svga monitor connection available Unit Controls: 4 LCD menu control buttons Hardware Warranty: Ethernet Port 2 years Swappable Port Interface Cartridges Fuse Alarm Relays Dual Power Feeds with GMT Fuses

15 NetGuardian 832A It's just a fantastic product. The NetGuardian does what it says it can do, and actually a lot more. Mark Renne, Program Manager Powerful, high-capacity, versatile SNMP alarm collector covers all your remote monitoring needs The NetGuardian 832A does as much as an RTU can... and then it does a whole lot more. The NetGuardian s primary function is to mediate contact closures and analog voltages to SNMP traps but it also serves as a reach-through terminal server, a self-contained all-in-one alarm monitoring system, a 24/7 and paging system. and then there s still more functionality... The NetGuardian 832A provides all the tools you need to for complete remote site management: Mediate 32 discrete inputs, 32 ping alarms, and 8 analog alarms to SNMP traps. Report alarms to multiple SNMP managers or T/Mon NOC Supports LAN or dial-up transport immediately implement SNMP monitoring without LAN or use dial-up as a backup path in case of LAN failure. Monitor legacy telephony gear, battery plants, generators, security locks, temperature sensors, and all your other remote site equipment. Expand your monitoring capacity up to 176 discrete inputs with the NetGuardian Expansion Unit. 4-threshold analog monitoring (Major Over, Minor Over, Minor Under and Major Under). Control site equipment with 8 control relays. Control switches, routers, PBXs and other telecom gear through the NetGuardian s 8 terminal server reachthrough ports. Integrated Web Browser interface for stand-alone alarm monitoring. and pager alerts for 24/7 alarm monitoring without a master. Live streaming video surveillance of remote sites with the NetGuardian SiteCAM. Included Windows configuration utility. Free lifetime firmware upgrades. NEBS Level 3 Certified The NetGuardian Web Browser Interface provides standalone local monitoring. To order, call or visit 15

16 Grounding Post Sensor Fuse External Sensor Power Feed Data Ports Connector for Optional NetGuardian Expansion Connector for Optional GLD Dual Power Feeds Protocols: SNMP and DCPx 1 Amp Temp Sensor Analogs 7 8 Analogs 1 6, Relays 1 8, GMT Fuse and Discretes Discrete Inputs: 32 (expandable to 176) Discretes 1 24 NetGuardian 832A Specifications Alarm Detection Speed: User-defined (3 to 999 msec) Analog Inputs: 8 Analog Input Range: (-94 to 94 VDC or 4 to 20 ma) Control Outputs: 8 Form C relay contacts Maximum Voltage: 60 VDC/120 VAC Maximum Current:1 Amp, AC/DC IP Address Ping Targets: 32 Interfaces: 8 DB9 RS-232 ports 1 RJ45 10BaseT Ethernet port 1 RJ11 POTS jack 2 50-pin amphenol connectors (discretes, controls, and analogs) 1 DB9 connector (analogs) Modem: 33.6K internal Visual Interface: LCD display with descriptive text 16 bicolor LEDs Audible Interface: Alarm speaker Telco Jack Dimensions: 1.75"H x 17"W x 12"D (4.5 cm x 43.2 cm x 30.5 cm) Weight: 4 lbs. 3 oz. (1.9 kg) Mounting: 19" or 23" rack Ethernet Jack Power Input: 48VDC ( 40 to 70 VDC) see options Current Draw: 200mA Fuse: 1 Amp GMT Operating Temperature: F (0 60 C) Operating Humidity: 0% 95% noncondensing The NetGuardian's included Windows configuration utility makes it easy to create standard configurations and upload them via LAN. 16 To order, call or visit

17 NetMediator T2S Send TBOS Alarms Directly to Your SNMP or TL1 Manager The NetMediator is like an RTU on steroids - it does everything the NetGuardian 832A does, and then some. It s a full-featured alarm collector and protocol mediation device in one. You can mediate and monitor, saving you the expense of buying additional RTUs. Protocols: SNMP, TL1, TBOS Mediation: 8 TBOS displays to SNMP or TL1 Discrete Inputs: 32 Analog Inputs: 8 (voltage/current) Analog Input Range: 70 to 94 VDC or 4 to 20 ma Control Outputs: 8 Maximum Voltage: 60 VDC/120 VAC Maximum Current: 1 Amp, AC/DC Interface: 4 RS-422/RS-485 TBOS ports 4 RS-232 serial reach-through ports 2 50-pin connectors 1 4-pin connector 1 RJ45 10BaseT Ethernet port 1 RJ11 POTS jack 1 DB9F craft port Visual Interface: 18 LEDs, LCD display Dimensions: 1.75 H x 17 W x 12 D (4.5 cm x 43.2 cm x 30.5 cm) Weight: 4 lbs. 3 oz. (1.9 kg) Mounting: 19 or 23 rack Power Input: +24 VDC Current Draw: 200 ma Fuse: 0.75 Amp GMT Operating Temperature: F (0 60 C) Operating Humidity: 0% 95% noncondensing To order, call or visit 17

18 Remote Alarm Block 176N Convert Contact Closures to SNMP Traps Right at Your MDF Ordinarily, if you want to get SNMP Traps from your Main Distribution Frame, you re looking at hours of work and a hefty price in technicians time and overtime pay. First you ve got to collect all the wires at your Main Distribution Frame and tie them down to a terminal block. Then you ve got to cross connect the wires from the terminal block to an SNMP RTU and that means running the wires over an equipment ladder and sewing them down. There s an easier way - the Remote Alarm Block 176N. It s a remote alarm block and SNMP RTU in one unit. The RAB installs right in your Main Distribution Frame. Tie all the wires to the RAB and the only thing you ve got going out is a nice, clean Ethernet cable straight to your LAN and your SNMP manager. 176 alarm inputs for dense alarm collection in the smallest possible space. Compact design frees space for revenue generating equipment 4 control relays for instant response to system integrity threats Selectable alarm qualification times separate nuisances from emergencies Free Windows configuration software included Free lifetime firmware upgrades Easy hardware replacement without having to disconnect wire-wrap dressing Mounts on rack or wall 18 To order, call or visit

19 Wire-Wrap Terminals 1 Amp Fuse 48 V Power connection and ground Ethernet Port Status LEDs Configuration DIP Switches Stereo Jack Craft Port Module Release Lever Remote Alarm Block 176N Specifications Protocols: SNMP, DCPx, DCPf, DCP, and DCP1 Discrete Point Inputs: 176 Alarm Detection Speed: Configurable to msec Control Outputs: Relay contacts, 2 Form A, 2 Form C Maximum Voltage: 60 VDC/120 VAC Maximum Current: 1 Amp, AC/DC Interfaces: 1 RS-232 or RS-485 serial port 1 stereo jack craft port 1 RJ-45 10BaseT Ethernet port Visual Display: 6 bicolor LEDs Dimensions: 4"x 8"x 5" (10.2 cm x 20.3 cm x 12.7 cm) Weight: 4 lbs (1.8 kg) Mounting: 19" rack, 23" rack, or wall mounting Power Input: 48VDC ( 40 to 70 VDC) Current Draw: 50 ma Fuse: 1 Amp GMT Operating Temperature: F (0 60 C) Operating Humidity: 0% 95% noncondensing The Remote Alarm Block s included software utility allows you to monitor alarms and control relays, analyze traffic, and upload the latest firmware. To order, call or visit 19

20 NetGuardian 216 If you think you can t monitor small sites costeffectively, the NetGuardian 216 will change your mind Are you monitoring your small sites? Do you think you can t afford to? The light-capacity LAN-based NetGuardian 216 for SNMP, TL1, and DCP makes it possible to install network monitoring anywhere in your network, without spending a fortune on excess alarm capacity. Right-size capacity for small sites: 16 discrete alarms, 2 analog alarms, 2 controls and 1 terminal server port. Reports alarms over SNMP, TL1 or to T/Mon NOC. Reports to up to 2 SNMP managers great for reporting alarms to different departments 4-threshold analog monitoring (Major Over, Minor Over, Minor Under and Major Under). Terminal server port for LAN access to switches, routers, PBXs and other serial-interface devices. Optional dual 48 VDC or 110 VAC power input. 2 small-footprint form factors for rack or wall mounting. Included Windows configuration utility for easy, quick turnup. Free lifetime firmware upgrades The NetGuardian 216 wall mount unit offers same 16 alarms, 2 analogs, and 2 controls as the rack mount unit in a vertical 6"H x 8"W x 1.75"D case, saving valuable rack space for your other network equipment. 20 To order, call or visit

21 Craft Port Status LEDs Volume Control Audible Alert Speaker ½ Amp Fuse and Fuse Alarm LED Grounding Lug Dual 48 VDC Power Inputs (Optional) Terminal Server Port 10BaseT Ethernet Port 4 Pin Analog Input 50 Pin Connector for Alarm Inputs and Control Relay Outputs NetGuardian 216 Specifications Protocols: SNMP, TL1, DCP, DCPf, DCPx, DCP1 Dimensions: 1.75" (1 RU) H x 8"W x 6"D Discrete Inputs: 16 (reversible) (4.5 cm x 20.3 cm x 15.2 cm) Analog Inputs: 2 Mounting: 19" or 23" rack Analog Input Range: 90 to 90 VDC Power Input: Analog Thresholds: 4 per analog input 48VDC ( 40 to 70 VDC) Control Outputs: 2 (Optional) Dual 48VDC inputs Maximum Voltage: 60 VDC/120 VAC (Optional) 9 VDC from 110 VAC wall transformer Maximum Current: 1 Amp AC/DC Current Draw: 50 ma Interfaces: Fuse: 0.5 amp GMT RJ45 10BaseT Ethernet port Operating Temperature: F (0 60 C) 50-pin alarm input connector Operating Humidity: 0% 95% noncondensing 4-pin alarm input connector Configuration and Monitoring Utility Included DB9 RS-232 terminal server port Downloadable Firmware via Craft Port DB9 craft port Visual Interface: 8 LEDs Audio: Speaker with volume control To order, call or visit 21

22 NetGuardian 480 The low-cost, easy-to-implement solution to monitoring your entire site with just one unit for SNMP or TL1 The NetGuardian 480 (NG 480) is a specialized member of the NetGuardian family, optimized for use as a high-capacity discrete-only responder. The result is a highly cost-effective solution for gathering the diverse equipment at your remote site and integrating it into a single modern network management system. With 80 discrete alarm inputs 2½ times as many as the NetGuardian 832A- you can easily forward all the alarms of a small to medium-sized site. This dense alarm coverage gives you the convenience of a single-box solution, saves you the cost of buying multiple low-capacity RTUs, and offers you the lowest possible cost per point. 80 discrete inputs cover your entire site with a single unit Convenient single-box solution saves costs of buying multiple units economical cost per point Reports to multiple SNMP managers, TL1 manager, or T/Mon NOC TL1 over TCP/IP Four control relays for controlling site equipment and security devices Configurable alarm descriptions include detailed, actionable alarm data in SNMP traps or TL1 autonomous messages Free Windows 2000/XP software for editing TL1 database, configuration, monitoring, diagnostics, and testing Standard dual 48 VDC power inputs for redundant power facilities Free lifetime firmware upgrades Transport Equipment Power Supply Systems AND/OR T/Mon NOC Additional Discrete Alarms SNMP Manager/TL1 Master Versatility and power: The NetGuardian 480 collects alarms from all the diverse equipment at your remote site and reports to multiple SNMP managers, your TL1 manager or T/Mon NOC 22 To order, call or visit

23 Dual Power Inputs Discretes 49-80, Controls 1-4 Discretes BaseT Ethernet port ½ Amp GMT Fuse Serial jack Protocols: SNMP, TL1, DCP, DCPx, DCPf, DCP1 Discrete Inputs: 80 NetGuardian 480 Specifications Alarm Detection Speed: Configurable to msec (1/10 second to 9 seconds) Control Outputs: 4 relay contacts, 2 Form A, 2 Form C Maximum Voltage: 60 VDC/125 VAC Maximum Current: 0.5 Amp, 125 VAC 1 Amp, 24 VDC Interfaces: Two 50-pin connectors for discrete alarms and control relays 1 RJ45 Ethernet jack 1 DB9 craft port 1 RJ11 serial port jack Visual Display: 6 LEDs Dimensions: 1.75" H x 17" W x 12" D (4.5 cm x 43.2 cm x 30.5 cm) Weight: 4 lbs. 3oz. (1.9 kg) Mounting: 19" or 23" rack Power Input: 48VDC ( 40 to 70 VDC) Current Draw: 250 ma Fuse: 0.5 Amp GMT Operating Temperature: F (0 60 C) Operating Humidity: 0% 95% non-condensing Easy, Efficient Configuration: The included configuration utility gives you full command of all the NG 480 s functions. To order, call or visit 23

24 My Promise to You By Bob Berry I don t think you should have to take any risks to get the alarm monitoring capabilities you need. If you decide to work with me, I won t let you fail. If my solution doesn t solve your problems 100%, I don t want you to have it. I have three goals: I want to sell my product, I want you to use my product, and I want you to be completely satisfied with my product. If my product doesn t fulfill those goals, I will fix it, improve it, or give you your money back. If my stuff doesn t wow you, I don t want your business. So here s my guarantee to you: if you buy a DPS Telecom solution, you can test at your site, under real-world conditions, for 30 days. If you re dissatisfied with it, for any reason, just send it back and you ll get a full refund, no questions asked. So please if you re interested improving your network alarm management and reliability, do yourself a favor and call us today at Your network s needs can t wait. I promise you we ll deliver a solution to your problems, at no risk to you. I wish you the best of success with your network management! Sincerely, Bob Berry Chief Executive Officer DPS Telecom Bob Berry Chief Executive Officer DPS Telecom DPS Telecom Your Partners in Network Alarm Monitoring We protect your network like your business depends on it TM

2007 Product Showcase

2007 Product Showcase 2007 Product Showcase Building Access System Secure Your Remote Sites pg.29 NetGuardian 216T SNMP RTU with T1 Transport pg 32 NetGuardian 832A G4 This product showcase for 2007 features the newest and

More information

2008 Product Showcase

2008 Product Showcase 2008 Product Showcase NetGuardian 832A G5 Wireless High-Capacity Alarm Collector pg. 18 Building Access System Secure Your Remote Sites pg. 31 NetGuardian 216T This product showcase for 2008 features the

More information

Network Alarm Monitoring Fundamentals

Network Alarm Monitoring Fundamentals Network Alarm Monitoring Fundamentals A solid introduction to alarm monitoring essentials: What equipment you must monitor How to design an alarm system to meet your current and future needs How to minimize

More information

Intelligent SNMP-Legacy Integration by Bob Berry

Intelligent SNMP-Legacy Integration by Bob Berry Legacy SNMP Legacy RTUs RTUs Battery Plants PBXs Microwave Radios Routers Switches Intelligent SNMP-Legacy Integration by Bob Berry Make your existing equipment SNMP-compatible Fast guide to how you can

More information

NetGuardian. and other RTUs

NetGuardian. and other RTUs NetGuardian and other RTUs 2 Factory Training Workbook NetGuardian Contents The NetGuardian 832A G5 NGEdit Software NetGuardian Hardware NetGuardian Setup NetGuardian Provisioning and Monitoring Troubleshooting

More information

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM Alarm Panel USER MANUAL [ PRELIMINARY HARDWARE MANUAL ] Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. May 7, 2008 D-OC-UM085.07010 v1.0a Revision History April 28, 2008 May

More information

Universal Monitoring System. TrapServer Description

Universal Monitoring System. TrapServer Description TrapServer Description TrapServer is a centralized or distributed monitoring system used to monitor, assess and control a multi-vendor telecommunications networks. It consists of a server (rack or desk

More information

Discrete Point Module (DPM) 216 G2

Discrete Point Module (DPM) 216 G2 Discrete Point Module (DPM) 26 G2 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. December 8, 200 D-OC-UM0C.800 Firmware Version.0A Revision History May 27, 20 Misc

More information

Quick Alert Remote (QA216R)

Quick Alert Remote (QA216R) Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location

More information

NetGuardian V16/M16 G2

NetGuardian V16/M16 G2 NetGuardian V6/M6 G2 USER MANUAL D-PK-26V2 D-PK-M6G2 D-PK-C6V2 Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. September 26, 206 D-UM-26V2 Firmware Version.0S Revision History

More information

NetGuardian 216 G3 USER MANUAL. Visit our website at for the latest PDF manual and FAQs.

NetGuardian 216 G3 USER MANUAL. Visit our website at  for the latest PDF manual and FAQs. NetGuardian 26 G3 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. February 9, 202 D-UM-NG26-200 Firmware Version 2.0K Revision History February 9, 202 Added Verizon

More information

DPS Factory Training

DPS Factory Training DPS Factory Training Factory Training Schedule What You ll Get from DPS Factory Training What to Bring to the Factory Training Event Las Vegas and Advanced Training Classes Map to DPS Telecom Headquarters

More information

User Manual DPM 208. Alarm and Control Network Element. Um119889

User Manual DPM 208. Alarm and Control Network Element. Um119889 User Manual DPM 208 Alarm and Control Network Element Um119889 DPM 208 Version 1.0B Alarm and Control Network Element Publication Number UM119889 Date of issue: 8-31-99 4955 E. Yale Ave. Fresno, CA 93727

More information

NetGuardian 480/432 G3 & G4

NetGuardian 480/432 G3 & G4 NetGuardian 480/432 G3 & G4 USER MANUAL D-PK-NG480 D-PK-NG432 Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. October 28, 206 D-UM-NG480/NG432 Firmware Version 2.0N Revision

More information

DPS Factory Training

DPS Factory Training DPS Factory Training Factory Training Schedule What You ll Get from DPS Factory Training What to Bring to the Factory Training Event Advanced Training Class Map to DPS Telecom Headquarters 2018 Factory

More information

Remote Power Switch (DC)

Remote Power Switch (DC) Remote Power Switch (DC) USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. November 0, 207 D-UM-26RP-200 Firmware Version.0J.083 Revision History November 0, 207 Added

More information

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM DPM & DPM-216 USER MANUAL May 21, 2009 D-OC-UM09.521200 Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A Revision History May 21, 2009 Released updated D-OC-UM09.521200 March 12, 2009 Released

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

idware Idware Remote Site Monitoring Solution

idware Idware Remote Site Monitoring Solution idware Idware Remote Site Monitoring Solution 2 TOPIC 1. Why a Remote Site Monitoring solution is mandatory for a TELCO? 2. Remote Site Monitoring features a) Power monitoring b) Security Monitoring c)

More information

wireless. web-based. worthy of the name RACO.

wireless. web-based. worthy of the name RACO. wireless. web-based. worthy of the name RACO. reliable monitoring unequalled accessibility on-demand reporting wireless, web-based alarm detection and notification system from RACO designed specifically

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

NetGuardian 480 G4 USER MANUAL. Visit our website at for the latest PDF manual and FAQs.

NetGuardian 480 G4 USER MANUAL. Visit our website at  for the latest PDF manual and FAQs. NetGuardian 480 G4 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 2, 203 D-UM-NG480 Firmware Version.F Revision History June 2, 203 Initial Release This document

More information

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

SensorHawk 4 PoE. For more information please visit us at   or call us at 1 (800) A high-speed, accurate and intelligent monitoring device. The Poe is a completely embedded host with a proprietary Linux like OS which includes TCP/IP stack, a built-in web-server and full Email and SNMP

More information

DPS Factory Training

DPS Factory Training DPS Factory Training Factory Training Schedule What You ll Get from DPS Factory Training What to Bring to the Factory Training Event Regional and Advanced Training Classes Map to DPS Telecom Headquarters

More information

NetGuardian LPG Controller

NetGuardian LPG Controller NetGuardian LPG Controller USER MANUAL D-PK-NGLPG Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 3, 205 D-UM-NGLPG Firmware Version.0A Revision History June 3, 205 Initial

More information

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION DATA SHEET BENEFITS Alarm Printers, Report Printer Replacement Better Operator Attention Alarm Rationalization Remote Viewing of Alarms Unlimited Archiving of Alarms\Event Messages Alarm Consolidation

More information

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software OVERVIEW The Keltron LS 7000 Alarm Management System software and computers make up the dispatch portion

More information

NetGuardian BSM and BSM-G2

NetGuardian BSM and BSM-G2 NetGuardian BSM and BSM-G2 USER MANUAL D-PK-NGBSM Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 10, 2018 D-UM-NGBSM Firmware Version 2.0A Revision History July 10, 2018

More information

Typical applications include the vibration detector. Detection of vibrations and shocks

Typical applications include the vibration detector. Detection of vibrations and shocks Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Outdoor Temperature Sensor

Outdoor Temperature Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Data Center. Cold Storage

Data Center. Cold Storage Sensaphone Monitoring Systems Accessories & Sensors SCADA 3000 Sensaphone 2800 & Wireless Sensors IMS Wireless Node & Sensors IMS Data Center IMS WIRELESS SOLUTION Cold Storage Communications Closet Data

More information

WEBs AX Security. Integrated Security With Simple, Web-Based Management

WEBs AX Security. Integrated Security With Simple, Web-Based Management WEBs AX Security Integrated Security With Simple, Web-Based Management Built-In Peace Of Mind Flexibility is the key to Honeywell WEBs-AX Security. Whether you need single site or enterprise access control,

More information

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are. RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are. he Verbatim Gateway from RACO, the remote monitoring and alarm specialists, allows you to use TouchTone telephones anywhere

More information

MiNi Server environment MoNitoriNg SySteM

MiNi Server environment MoNitoriNg SySteM enviromux-mini with enviromux-t-3 temperature Sensor Features & Applications Monitors threats: temperature Humidity Water Leakage intrusion The ENVIROMUX Mini Server Environment Monitoring System monitors

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

CAN unit for Analog Sensors

CAN unit for Analog Sensors CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

ADAM. TBOS Adaptor Board. Description. Specifications. Peripherals INTELLIGENT MONITORING THAT BRIDGES THE TECHNOLOGY GAP

ADAM. TBOS Adaptor Board. Description. Specifications. Peripherals INTELLIGENT MONITORING THAT BRIDGES THE TECHNOLOGY GAP ADAM 720 INTELLIGENT MONITORING THAT BRIDGES THE TECHNOLOGY GAP Peripherals TBOS Adaptor Board The ADAM 720 TBOS Adaptor Board makes upgrading your Westronics alarm system quick and easy with the ADAM

More information

Liebert. Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Liebert. Universal Monitor Monitoring, Control And Remote Communications For Critical Applications Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications LIEBERT UNIVERSAL MONITOR Monitoring and alarm capabilities designed to maximize the uptime of your critical

More information

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules For Obvius A89DC-08 sensor modules Introduction Large roof and ground arrays connect the panels into stings that are merged together in combiner boxes. Each string will typically consist of 10-15 panels

More information

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone

More information

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Combined CAN Sensor Unit Temperature, Humidity and Smoke Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical

More information

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution EnergyMaster ENEC Monitoring System An on-site supervision and remote monitoring solution ENERGYMASTER ENEC MONITORING SYSTEMS AN ON-SITE SUPERVISION AND REMOTE MONITORING SOLUTION Take Control of Your

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

Common Questions & Answers

Common Questions & Answers Common Questions & Answers Summary of Advantages Honeywell has proven manufacturing and design capability, distribution expertise and the field training/support necessary for a successful partnership with

More information

Situational Awareness for Life & Fire Safety. October 10, 2013

Situational Awareness for Life & Fire Safety. October 10, 2013 Situational Awareness for Life & Fire Safety October 10, 2013 New Fire Standards Control and Communication Units For Fire Alarm Control Units Mass notification products shall be constructed to comply with

More information

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server. v.100.00x A high-speed, accurate and intelligent monitoring device. The is a completely embedded host with a proprietary Linux like OS which includes TCP/IP stack, a built-in web-server and full Email

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Monitoring Solutions

Monitoring Solutions GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Galaxy Pulsar Plus Digital Battery Plant Controller

Galaxy Pulsar Plus Digital Battery Plant Controller Galaxy Pulsar Plus Digital Battery Plant Controller Features Supports up to 60 Power Modules rectifiers and converters Supports dual voltage plants, with rectifiers and converters Auto-sensing dual voltage

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra version: 7-05-03 CONTEG DATASHEET COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 79/4 40 00 Prague 4 Tel.: +40 6 9 8 Fax: +40 6 9 9 Production

More information

SENSAPHONE 901 Tryens Road Aston, PA PH:

SENSAPHONE 901 Tryens Road Aston, PA PH: SENSAPHONE 901 Tryens Road Aston, PA 19014 PH: 877-373-2700 www.sensaphone.com Why Choose Sensaphone Sensaphone products are designed to help you watch over a remote facility. Our range of Sensaphone solutions

More information

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) The Power of Reliability BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) INSTRUCTION MANUAL TABLE OF CONTENTS

More information

Electrolyte Monitoring Sensor

Electrolyte Monitoring Sensor Inspirations FEBRUARY 2014 The Latest in Asset Protection and Condition Monitoring Electrolyte Monitoring Sensor The Inspired Systems Electrolyte Monitoring System is a breakthrough product that nonintrusively

More information

Perimeter Product Overview. Effective protection for your business

Perimeter Product Overview. Effective protection for your business Perimeter Product Overview Effective protection for your business The Gallagher difference Our innovation is driven by the desire to solve problems, meet your needs and provide real business value. We

More information

TELECOMMUNICATION. Telecommunication. Wireless Phone

TELECOMMUNICATION. Telecommunication. Wireless Phone TELECOMMUNICATION Telecommunication Wireless Phone Talkback System CCTV PAGA TV Distribution LAN / WAN System 25 Telecommunication Telecommunication projects in the Oil & Gas industry are often large,

More information

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1% DC Voltage Sensor Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

How to Remotely Monitor Your Trackside Cabinets & Telecom Sites

How to Remotely Monitor Your Trackside Cabinets & Telecom Sites How to Remotely Monitor Your Trackside Cabinets & Telecom Sites DPS Telecom Why should I listen to this guy? 11 years with a remote-monitoring manufacturer Interviewed our rail clients What I learned recently:

More information

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure. Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

SYSTEM OVERVIEW. Environmental Monitoring. Simplified.

SYSTEM OVERVIEW. Environmental Monitoring. Simplified. SYSTEM OVERVIEW Environmental Monitoring. Simplified. Uptime Devices designs Environmental Monitoring products for businesses of all sizes. APPLICATIONS Data Centers Cold Storage Power Plants Manufacturing

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

UltraSync Modular Hub

UltraSync Modular Hub Intrusion UltraSync Modular Hub UM-5000-CPU OVERVIEW The UltraSync Modular Hub is a smart security system ideal for residential installations requiring hardwired and/or wireless intrusion systems, as well

More information

AirFlow Sensor for Dry Contact connection

AirFlow Sensor for Dry Contact connection Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Innovative protection that combines power and flexibility

Innovative protection that combines power and flexibility Innovative protection that combines power and flexibility Desigo Fire Safety Modular outpaces industry standards and includes cutting-edge detection and communication capabilities usa.siemens.com/desigo-fs-modular

More information

TELSEC MINI PRO User Guide

TELSEC MINI PRO User Guide TELSEC MINI PRO User Guide Rev 1.6 10/25/16 CRITICAL APPLICATIONS DISCLAIMER QUEST CONTROLS PRODUCTS ARE NOT INTENDED OR AUTHORIZED FOR USE IN ANY APPLICATION THAT REQUIRES FAIL-SAFE OPERATION, OR ANY

More information

COMMUNICATOR ET08 / ET081

COMMUNICATOR ET08 / ET081 COMMUNICATOR ET08 / ET081 User Manual v1.2 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: GSM communicator ET08 / ET081 (further

More information

Hugs Product Guide Specification

Hugs Product Guide Specification Stanley Healthcare Solutions 309 Legget Drive Ottawa, ON K2K 3A3, Canada Tel: 1.866.559-6275 Int l: +1 (613) 592.6997 Fax: (613) 592.4296 Web site: www.stanleyhealthcare.com E-mail: hugssupport@stanleyworks.com

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you.

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you. What Is A? Humidity Smoke Frozen Pipes IT MONITORS A monitors a remote location and contacts you when problems are detected. You can check at any time to make sure everything is okay. IT NOTIFIES YOU products

More information

NetGuardian DIN/ NetDog DIN

NetGuardian DIN/ NetDog DIN NetGuardian DIN/ NetDog DIN USER MANUAL D-PK-NGDIN Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 2, 2018 D-UM-NGDIN Firmware Version 1.0A Revision History July 2, 2018

More information

NU2 Smart Power Supply (SPS) Manual

NU2 Smart Power Supply (SPS) Manual GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC.

More information

Installation Manual COPYRIGHT NOTICE

Installation Manual COPYRIGHT NOTICE Installation Manual COPYRIGHT NOTICE Copyright 2007 by Quest Controls Inc (QUEST). The material discussed in this publication is the proprietary property of QUEST. QUEST retains all rights to reproduction

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Dual Bus Distribution Panel Series INSTRUCTION MANUAL 855-314-000 Models: ICT200DF-12IRC ICT200DB-12IRC WARNING Risk of serious personal injury or damage to equipment

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

How to Read and Understand the SNMP MIB by Marshall DenHartog

How to Read and Understand the SNMP MIB by Marshall DenHartog DPS Telecom Your Partners in Network Alarm Monitoring How to Read and Understand the SNMP MIB by Marshall DenHartog A complete guide to the SNMP Management Information Base: Understanding the purpose and

More information

Front page TBA from Marketing. Network and Device Monitoring. Starter Kit

Front page TBA from Marketing. Network and Device Monitoring. Starter Kit Front page TBA from Marketing Starter Kit Table of Contents Before you start... 3... 3 Activity 1 Current Network Device Status... 4 Activity 2 Node Voltage Monitoring... 5 Activity 3 Personnel Device

More information

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications. Monitoring Catalog 0 Data Input Processing MM Transfer SW Applications Data Input Processing MM Transfer SW Apps HW group s. r. o. is a Czech manufacturer of monitoring and remote control solutions. We

More information

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12 AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

KEY FEATURES EASY ACCESS. Through web browser for both clients and administrators CLIENT MONITORING. Not dependent on access to site network

KEY FEATURES EASY ACCESS. Through web browser for both clients and administrators CLIENT MONITORING. Not dependent on access to site network Remote Monitoring of All Sites in One Tool Monitor energy and performance on multiple sites Statistics on energy produced Instant status overview KPI (Key Performance Indicators) Alarms Detect underperforming

More information

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance. Connected Industrial EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance. Local gas distribution companies supplying commercial and industrial customers

More information

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches integrate everything only afi delivers comprehensive security network infrastructure The network appliances typically deployed in security networks were most likely manufactured for general network connectivity

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

N-8000 SERIES IP INTERCOM SYSTEM

N-8000 SERIES IP INTERCOM SYSTEM N-8000 SERIES IP INTERCOM SYSTEM IP Network-Compatible Intercom System with Packet Audio Technology developed with cutting-edge TOA technological strengths for greater versatility and improved sound quality

More information

Faster and smarter ways to protect what matters most. Our Next Generation portfolio

Faster and smarter ways to protect what matters most. Our Next Generation portfolio Faster and smarter ways to protect what matters most Our Next Generation portfolio 2 Contents 3 Why Redcare 4 Say hello to our Next Generation portfolio 5 How our new products stack up 6 Get to know Essential

More information

Trident User s Manual

Trident User s Manual Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS

More information

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5) Tech Data Sheet D01662GB1_Esgraf 4.1 and Configuration Server 30/2011 1/(5) Esgraf 4.1 graphical user interface, configuration server and fire detectors contamination monitoring Esgraf 4.1 ESGRAF is a

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

Process alarm. Deliver messag e. Alarm event. Feedbac k. Process feedback

Process alarm. Deliver messag e. Alarm event. Feedbac k. Process feedback Messenger@Net Messenger@Net Messenger@Net is a PC based middleware that delivers real-time alerting of significant enterprise events from virtually any input source to virtually any remote notification

More information