MAIN OFFICE PT 7876, RUMAH KEDAI 1 ½ TINGKAT, JALAN KEMAMAN-DUNGUN, KEMAMAN, TERENGGANU DARUL IMAN

Size: px
Start display at page:

Download "MAIN OFFICE PT 7876, RUMAH KEDAI 1 ½ TINGKAT, JALAN KEMAMAN-DUNGUN, KEMAMAN, TERENGGANU DARUL IMAN"

Transcription

1 MAIN OFFICE PT 7876, RUMAH KEDAI 1 ½ TINGKAT, JALAN KEMAMAN-DUNGUN, KEMAMAN, TERENGGANU DARUL IMAN WAREHOUSE & TRAINING CENTRE WAREHOUSE 22, DOOR 4 & 5, KEMAMAN SUPPLY BASE PHASE 2, KEMAMAN, TERENGGANU DARUL IMAN TEL : /4484/4485 FAX : / rhslocal@rhstech.com Sales & Marketing. : enquiry@rhstech.com

2 PROJECT EXPERIENCES 2

3 LONG TERM CONTRACT LIST NO START DATE CONTRACT DURATION BRIEF SCOPE CLIENT STATUS Dec-07 5 Years (3 + 2) Provision of General Instrumentation Maintenance & Servicing for PM3 and PM305 COMPLETED 2 19-Jun-07 3 Years (2 + 1) Provision of Maintenance Instrument Services for PM & Labour Work of Analyzer at GPP - A ( 2+1) Gas Berhad COMPLETED 3 15-Oct Year Price Agreement for Electrical Maintenance Services and Any Related Work for East Coast Regional Office and Kerteh Airport Management Department, Kerteh, Kemaman, Terengganu Darul Iman Nasional Barhad COMPLETED 4 31-Dec-12 3 Years Provision To Provide Skilled Manpower, Materials and Tools for Preventive Maintenance and Services of Smoke Detector Alarm System at Warehouse KSB ON GOING 5 12-Dec Year Provision Of Inspection, Servicing and Calibration Of Protective Relays for PCSB - Sabah Operations PCSB - SBO ON GOING 6 16-May Year The Price Agreement Supply, Install & Deliver Fire Alarm Maintenance And Spare Part Items To Gas Berhad, Transmission Operation Division (PGB TOD), Segamat, Johor PGB TOD ON GOING 7 July-13 3 Years Provision for Service and Calibrate of Portable Gas Detector FPSO Ventures Sdn ON GOING 8 15-Oct Years Provision of General Instrumentation Maintenance Services ON GOING 9 Mei Months Provision Of Manpower and Rental Services For Instrumentation Maintenance ON GOING 10 7-Sept years Provision Of General Instrument Maintenance And Services ON GOING 3

4 CURRENT ELECTRICAL PROJECT NO START DATE BRIEF SCOPE VALUE (RM) CLIENT 1 Mei-2014 ACB Calibration at Erb West Platform Sabah Operation 2 Jun-2014 Site Verification For Relay Calibration Work At SOGT 7, Sabah Operation 3 July-2014 Relay Calibration at Tembungo Platform 29, Sabah Operation 4 August-2014 Relay Calibration at SBGAST 22, Sabah Operation 5 Sept-2014 Supply of Relay Sparepart 192, Sabah Operation 6 August-2014 Supply Of Lamp Lighting for FSO MOPU 1, August-2014 To Supply Measuring Device & Meter, Electrical Meter for FPSO Bunga Kertas 6, August-2014 Supply lamp, lighting and bulb

5 COMPLETED PROJECT : ELECTRICAL REV 09/14 ELECTRICAL: INSTALLATION & MAINTENANCE WORK NO START DATE CONTRACT DURATION BRIEF SCOPE VALUE (RM) CLIENT 1 6/11/ weeks Cablings Work for GPP 2, 3 & 4 Boiler Panel 19, GE BETZ 2 18/01/ Weeks 3 29/1/ weeks 4 2/4/ Weeks 5 18/02/ Weeks 6 8/3/ week 7 1/4/ months 8 13/04/ week To Carry Out Study On Earthing and Lighting Protection System at PM9 Platforms 40, Helideck Lighting Revamp at Bekok-A & C Platform 665, Junction Box MOL Pump Cable Installation at 35, Bekok-A Platform Conduct full inspection and maintenance for Generator G420 88, Supply of Manpower for performing Cable 2, Nusa Armada Insulation Test at PGB E&I Top Side Maintenance Contract To Provide Manpower, Tools, Equipment & 99, Engineering Sdn Consumables for Generator G400 Repair and Maintenance at Bekok A Supply Manpower Supervise Installation & Commissioning Work at Tiong-A, B & Kepong- 2, A 9 28/04/04 3 weeks KSB Open Yard Cable Laying 20, E&I Top Side Maintenance Contract Supply of Manpower, Material, Equipment and 10 2/5/ weeks Consumables for Lay New Power Cable from 20, Stock Chemical Yard to Existing Panel at PCSB Open Yard Supply of Manpower, Materials, Equipment & 11 05/05/ weeks Consumables for Generator G-400 Repair & Maintenance at Bekok-A Platform 100, Engineering,Procurement,Construction and Commissioning for the Replacement of Faulty 12 20/05/04 4 weeks Explosion Proof Fixtures at OGT 1) Variation Order for the Replacement of 706, Faulty Explosion Proof Fixtures at OGT 13 27/05/04 2 Weeks Refurbishment of Turbine Generator Busduct Enclosure at Tiong-A 310, /6/ week 15 16/06/04 1 Week 16 28/06/04 2 Weeks 17 21/07/ Weeks 18 19/07/ Week 19 12/8/ weeks 20 24/08/04 1 Week E&I Top Side Maintenance Contract To Supply & Install Junction Box for MOL Pump 17, Engineering Sdn Engineering Sdn Gas Compressor Piping (Tinggi-A Optimization) 67, Rewiring Coalescer Pumps P-1520, P-1524 & P-1528 Panels & 'Junction Boxes' 94, Repair and Servicing of sea water lift pump motor at Dulang B Platform - Manpower 134, Upgrade in Method of Connection of normal & Emergency Power Supply at Dulang B 73, Rewiring Lighting Points at Kerteh ESSO Complex To Troubleshoot and Rectify Fault at PCSB KSB Warehouse Num 5. (Option 1) 230, Engineering Sdn 20,

6 21 21/10/ Week Nov-04 2 Weeks 23 12/09/ weeks 24 10/01/ Week 25 07/02/ Weeks 26 15/02/ Week 27 27/02/ Week 28 03/07/ Weeks 29 03/07/ weeks 30 23/03/ weeks 31 20/04/ Week 32 25/04/ Week 33 28/06/ Weeks 34 24/07/ Week 35 09/08/ Week 36 22/09/ Weeks 37 20/12/ Week 38 28/2/ Weeks 39 08/03/ Weeks To Supervise Work for UPS Upgrading at Duyong Remote Platform Supply of Manpower, Material, Tools & Equipment for Resak Project To Service Manpower,Tools Consumables For Rewiring Socket Outlet at Block A,B & C KOP Building Supply of Project Supervisor for Wellhead Area Lighting Installation at Tinggi A Platform Supply Manpower 1 HV and 1 Wireman for SWLP Installation at Dulang B Platform Supply of CSR for Distribution Board Upgrade at Pulai A Platform Supply of CSR for Helideck Lighting System Upgrade at Tiong A Platform Upgrade of Pedestal Crane Floodlight Cables at AnPG - A Upgrade of Electrical Lighting System of Warehouse 4 and Warehouse 5 at KSB Provision for Supply of Manpower, Tools & Equipment for Testing and Calibration of Electrical Protective Relays & Breakers for Resak Platform Provision for Supply of Manpower, Tools & Equipment for Calibration and Commissioning of Soft Starter for MOL Pump at Pulai A Platform Supply of Manpower 1 HV Chargeman, 1 Wireman & Termination Kit for SWLP's Motor Installation at Dulang B Platform Transformer Servicing and Condition and Performance Study for T-415 and T-416 at Duyong CPP Supply & Installation of Cable & Breaker for LV Switchgear Room OGT Supply of Manpower To Conduct Full Servicing, Inspection & Intergrity Test On ACBs Generator at Bekok A Supply of Manpower, 1HV Chargeman, 1 Wireman and Termination Kit for SWLPs Motor Installation at Dulang B Installation of TG Motor Starter at Duyong CPP Platform Repair and Troubleshoot Lighting at Kemaman Supply Base Warehouse and Open Yard Test for Transformer, Dicrimination Study for Relays and Redraw CCR at OGT 3, , , , , , , , , , , , , , , , , , , /03/ Week ABB LV Starter / INEAX IMCS Works Troubleshooting Works at Angsi-CPP) ( ABB 38,

7 41 23/03/ Week 42 29/03/ weeks 43 04/04/ weeks 44 19/04/ weeks 45 19/04/ Weeks 46 05/10/ Weeks 47 28/5/ weeks Inspect and Trouble shooting of 2 units ICCPs at OGT Duyong CPP TG Motor Starter Installation Works - Breakers Installation OGT General Maintenance Services On Electrical Facilities - Rectify Flare Beacon Light Faulty at Onshore Gas Terminal Repair and Troubleshoot Lighting at KSB Warehouse and Open Yard To Upgrade the Compressor Skid Enclousure Lighting Cables Conduct and The Light Fittings at Tinggi A Platform OGT General Maintenance Services On Electrical Facilities -Conduct Study and Upgrade Lighting for Switchgear Room at OGT To Upgrade The Compressor Skid Enclosure Lighting Cables Conduct and The Light Fittings at Tinggi A Platform 74, , , , , , , /5/ weeks To Install & Commissioning Equipment at GPP-3 204, /6/ week To Supply and Install 3 units Magnetic Lock at Inspection Building at GGPA 8, /6/ weeks Installation of TG Motor Starter at Duyong CPP 79, /07/ Weeks OGT CP Repair Works, Install New Anode Groundbed Deepwell Type at OGT 97, /07/ Week To Rectify : 1) Connection / Terminal Lug / Cable at Fire Water Pump and Air Compressor 2) Circuit Breaker System for Capasitor Work 5, /08/ Week 54 13/08/ Weeks 55 4/9/ weeks 56 7/9/ weeks Conduct Study and Upgrade Lightning Crude Meter Skid on Module - 2 Add Extra Loud Speakers at High Noise Area at ANPG-A & ANDR-A Supply and Install New UPS and Charger which were Malfunction at DLB To Supply and Lay Low Voltage Cable for PC1704D DC Charger and Battery Servicing at CUF Gebeng, Kuantan, Pahang 55, , , , /09/ Weeks Rectify and Replace Lighting Fictures at KOCC area at OGT 20, /9/ weeks PA System for Admin Area at CUFG 41, /10/ weeks 60 1/10/ weeks Survey, Evaluate and Verify Earthing and Bonding System To Cater Lightning Protection System at OGT Survey,Evaluate and Verify Earthing and Bonding System to Cater Lighting Protection System at OGT 32, ,

8 61 03/10/ Week Install Multi Cable Transit (MCT) at Control Room 37, /11/ Week Reinforce The Interggrity of Earthing System, Cabling and Bonding at Pulai A Platform 7, /12/ Week Reclification of Earthing System at Duyong Platform 2, /2/ Weeks To Supply and Install Electrical Package for New Electroclorinator for Water Injection System at Dulang B Platform. 58, /03/ Weeks To Install JB & Socket and Lighting at Mustering Station at OGT 32, /03/ Weeks To Upgrading and Optimisation Impress Cathodic Protection 50, /03/ Week To Repair Faulty Underground Cable #P-0012 at OGT 39, /03/ weeks Module Lighting Upgrade at Pulai A 198, /04/ Week 70 19/04/ weeks 71 07/05/ Weeks To Upgrading and Optimisation Impress Cathodic Protection - Kirk Cell Polarization Dulang B TG 634 Alternator Services at Dulang B Platform Service of Genset at Bekok B (65KW) and Kepong A (30KW) 12, , , /05/ Weeks SCPA Alternator Service at Sotong Platform 49, /06/ Weeks Provision To Supply Manpower and Materilas for Cable Tdying Up Job at Angsi C & E Platform 36, /07/ Weeks To Replace /Change of Oil Transformer 2 unit 43, /07/ Weeks Service of Genset at Bekok B (65KW) and Kepong A (30KW) 13, /07/ Week To Install Additional 3 Phase 30A Isolator at Main Deck at Tinggi A 35, /08/ Week Dulang Earthing Inspection and Services 24, /08/ Week 79 16/08/ Week Supply Manpower and Material for Standby HV Power Cable at FSO Puteri Dulang To Upgrading and Optimisation Impress Cathodic Protection - Anode Well Head 18, , /09/ Weeks To Relocate Socket Outlet at Mustering Area at OGT 33,

9 /09/ /09/ Week 2 Weeks Module Lighting Upgrade at Pulai A 66, To Rectify and Install Earthing Cable for Compressor Control Panel ( To Provide Clean Earth ) 12, /10/ Weeks To Upgrade Earth Protection at Dulang D 41, /11/ weeks Service of Genset at Tiong A (65KW) 35, /11/ Weeks Sea Water Lift Pump Power Cable Damaged 32, /11/ weeks 87 17/12/ Weeks 88 06/01/ Weeks To Procure, Supply and Install Of Electric Materials for Pulai A Flare Ignitation System Upgrade at Pulai A Platrorm Package for Installation Ventilation at MTBE Warehouse and Laboratory To Rectify Shorted Cable ( for Back-Up Power) from LV Switchgear to KOCC at OGT 47, , , /01/ Weeks SCPA Alternator G3060 Service at SCPA Platform 57, /02/ Week 91 12/02/ Weeks 92 17/2/ Year To Route Additional Line (cable) for Locl Area Network (LAN) and telephone at Pulai A To Repair The Load Shedding System at Duyong Platform Perkhidmatan Penyeliaan dan Pemeriksaan Pemasangan Alat-Alat Elektrik di Pejabat Kerteh Port 36, , / Month 93 18/02/ weeks To Fabricate, Install and Commissioning of Pump Socket Reciprocal at OGT 174, /02/ weeks Module Lighting Upgrade at Tiong B and Kepong 258, /3/ Weeks Supply and Install Auto Trans Starter Panel 8, /03/ weeks To Procure, Supply and Install Of Electrical Materials for Tinggi A Flare Ignation System Upgrade 37, /1/ Week Provision to Supply, Install, Testing and Commissioning One Set DC Power System to PCSB Rectifier at Bukit Jerung, Marang, Terengganu 38, /01/ Weeks To Repair and Service Alternator G-410C at Tiong A 46, /03/ Weeks Procure, Supply and Install Of Electrical Materials for Tinggi A Instrument Air Compressor Upgrade 69, /02/ Weeks To Supply LV Chargeman for FSO Puteri Dulang 33,

10 100 04/02/ Weeks To Supply LV Chargeman for FSO Puteri Dulang 33, /04/ Week Cable Jointer for SWLP at Dulang 23, /04/ Week /04/ weeks /04/ Weeks To Supply and Install of Two (2) Unit Genset at Bekok C To Inspect and Rectification The Heat Tracing Problem at DLA To Procure, Supply and Install Of E & I Materials For Bekok C Starting Air Compressor Upgrade at Bekok A 79, , , /04/ Week To Service Alternator for TG360C at Bekok C 48, /05/ Weeks To Replace Fuse Protection With Circuit Breaker (CB) and Install ELR at OGT 69, /05/ weeks To Repair Earthing Cable at Jacket Leg at Duyong 73, /05/ Week To Replace Cable at Jet Fuel Pump at Duyong 22, /06/ Weeks To Repair MMI Software for Duyong Load Shedding at Duyong CPP 59, /06/ Weeks Sotong Infill Drilling 120, /06/ weeks /07/ Weeks /07/ Weeks /07/ Week /07/ weeks /07/ Weeks /08/ Weeks Supply Manpower, Materials, Equipment and Consumables for Electrical Package of New Electrochlorinator To Supply and Install Electrical Materials for Motor Oil Transfer Pump Urgent at Tiong A To Service Alternator G415 For Standby Genset G415 at BEC To Install New Electrical socket at Skid Metering at OGT To Rectify Electricity Of Portable Generator at Pulai B Provision To Supply, Remove and Install Electrical Accessories, Consumable and Manpower for Air Compressor Upgrade at Angsi To Rectify One Unit Panel Board at Living Quarters at Tiong A 107, , , , , , , /08/ weeks Power Quality Study at Dulang 210, /09/ weeks To Repair/Service and Relocate Automatic Voltage Regulator For Turbine Generator 45, /09/ weeks Provision To Supply Competent Manpower and Certified Testing Equipment For Electrical Maintenance for Angsi Shutdown 512,

11 121 11/09/ weeks Provision To Supply Competent Manpower to Install MOL Pump at Angsi 167, /09/ weeks To Do Lighting Maintenance at Angsi 122, /09/ Week Earthing and Bonding Inspection at Abu Cluster 26, /09/ Month /09/ Weeks /09/ Week To Supply and Install Of One Unit Genset 500Kv and IMW, 480 V, 60Hz, 1800rpm at Bekok C Provide Scaffolding For Module Lighting Upgrade at Pulai A Modify and Relocate Panel ME 600F For Air Cond at Pulai 71, , , /09/ Month Rental of One Unit Of Diesel Generator at Malong 43, /09/ Month TG 800 Alternator Services at Dulang B 919, /09/ weeks To Repair and Service One Unit Alternator at Tinggi 104, /11/ Week To Conduct Busduct Upgrading survey at Bekok C 32, /11/ Week Power Stability Survey at Bekok C 21, /11/ Weeks /11/ Weeks To Supply Manpower for MOV Installation at Duyong Supply, Install, Testing and Commissioning Of Electrical Tie Up at Sotong MASA 17, , /11/ weeks Transformer PPM (2008) at Resak 49, /11/ weeks Flare Ignition Panel Upgrade for Resak Platform 53, /12/ Weeks To Do Earthing / Grounding Survey at PGB 26, /12/ Weeks To Service of 65KW Diesel Genset for Kepong A 53, /12/ Weeks To Provide Flood Light at Each Jacket Leg for Boat Landing at Abu A 63, /12/ Week To Supply and Install One Unit Genset 500KVA at Bekok C 16, /01/ Week Install New Soft Starter For MOL Pump P160 B and To Rectify Bus Bar G410A at Tiong A 9, /01/ Week To Rectify IMCS Interface Module at Resak 25,

12 142 19/2/ Weeks Provision to Refurbisment Alternator G410B at Tinggi A for PCSB - PMO 98, /03/ Week Dismantle/Remove Busbar G410C at Tinggi A and Modify, Installation at Tiong A 23, /3/ Weeks Provision to Supply of Manpower, Tools & Equipment for Refurbish Busduct at Bekok C 106, /04/ Week /05/ Week /06/ Month To Provide Manpower, Material, To Supply and Replace Two Unit Radar Transmitter to TCOT tank Storage Facikities at TCOT Provision To Provide Specialist For Troubleshooting NOA at Bekok C Extension Of Rental Duration for 80KW Genset at Sotong 20, , , /06/ Month Dulang A & D Work Over campaign Project 385, /06/ Week /06/ Week /06/ Weeks /06/ Week /07/ Week /07/ Weeks /07/ Weeks To Modify the griddle Lang for oven at Dulang B Manpower Services for Duyong Second Source Fuel Gas Project at Duyong To Replace and Modify MOL Pump Junction Box and Glands at Tinggi To Supply Cable and Manpower For PWT project at Pulai A To Refill and Service Water Mist Cylinder/System at C-270B at TCOT Four Way Cable Ladder For Air Compressor at Resak Four Way Cable Ladder For Air Compressor at Resak 33, , , , , , , /07/ Week Cleaning and Servicing Generator Bus Bar at Pulai A and Tinggi 19, /08/ Week Cleaning and Servicing Generator Bus Bar at Tiong A 29, /08/ Week To Repair UPS 01 Module Card at OSC 15, /08/ Weeks Rental 32KW genset for Bekok B 14, /08/ Weeks Duyong SIPROD - Preparation and Rig Up Package at Duyong 233,

13 161 27/08/ Week Earthing Bonding at Dulang 30, /09/ Week Earthing Bonding at OGT 20, /09/ weeks To Supply Manpower and Equipment for Water Injection Motor P4040C Bearing Replacement at Angsi 144, /09/ Month To Rent Air Compressor at Anding 65, /09/ Weeks Genset Servicing GPP3 Turn Around , /09/ Month Rent Of Air Compressor at Abu A 37, /09/ Weeks To Rectify Underground Cable Faulty at OGT 23, /10/ Week Site Survey To Install Water Maker at Abu A 25, /11/ Week To Service and Rectify alternator for DG221 at Pulai B 18, /11/ Weeks Replace and Upgrade Distribution Board at Electrical Workshop at Tinggi 43, /11/ Week To Conduct Earthing Bonding Activity at Malong 19, /11/ Week Rejuvination Project at Pulai B Platform 18, /11/ Weeks /11/ Days To Conduct Earthing Bonding Visual Inspection at Bekok A/B 53, Provision To Supply Manpower and Material for Bekok C Workover SIPROD - SITE SURVEY 4, /11/ Week /12/ Week /12/ Month /12/ weeks Site Support Service for Air Compressor Commissioning at Resak To Purchase Materials and Supply manpower for 2 units Coarse Filter for Water Injection Module at Dulang B To Rent Portable Generator at Puteri (Bunga Kertas) ( including cable for termination) 16, , , Provision To Supply Manpower and Material for Bekok C Workover SIPROD 127, /12/ Weeks /3/ Month To Install A New Battery Cell for the Charger 032A/B at TCOT 43, Provision to Supply Rental of Portable Transformer 800KVA for LQ at Duyung Platform-PCSB. 230, PCSB 13

14 181 4/10/ Month /11/ Month To Rectify Malfunction Capacitor Bank at Kerteh Airport 7, Provision of Upgrading LQ Power Supply From 110V to 240V at Tiong Platfrom for Carigali, Peninsular Operation 66, PCSB PCSB /05/2010 N/A Provision To Rental of Portable Power Transformer for Duyong LQ 230, Sdn /05/2010 N/A Provision To Supply, Installation and Commissioning of Fusible Plug Loop system at Duyong 121, Sdn /05/2010 N/A Modification of Piping From Drumming and Road truck Tanker Facilities 14, Sdn /06/2010 N/A E & I Work For SCMD open Warehouse Upgrade at Ethylene 215, Sdn /08/2010 N/A Replacement Of Instrument Cable at Q101 During GPP1 MIM Turnaround 2009 at GPPA 28, Sdn 45 28/09/2010 N/A Provision To Supply, Install, Testing and Commissioning of Three (3) Units New Softstarters for CTO Electric Motors for PCSB 207, Sdn /09/2010 N/A Motor and MCC Service, Relay Calibration at CUF Kerteh 15, Sdn /10/2010 N/A To Rectify Malfunction Capacitor Bank System at Kerteh Airport, Kerteh, Kemaman 7, Sdn /10/2010 N/A The Price Agreement For The Electrical Maintenance Service and any Related works For East Coast Regional office and Kerteh Airport Management Dept 200, Sdn /11/2010 N/A Provision Of Upgrading LQ Power Supply from 110V to 240V at tiong Platfrom 72, Sdn /02/2011 N/A The Proposed Rewiring Works and Power Distribution Enhancement at Kerteh Airport 206, Sdn /04/ Months /11/ Month /09/2011 N/A /09/2011 N/A The Proposed Rewiring Works and Power Distribution Enhancement at Kerteh Airport, Kerteh, Kemaman, Terengganu 206, To Perform Project of Laying Power Cable at CUF Kerteh 34, Provision to Supply, Install, Testing and Commissioning of Three (3) Units Soft Starters for CTO Electric Motors for Carigali Peninsular Operations 207, Supply Manpower for Installation NDB at Bekok A and BEC 2, ECRO PCSB Sdn 14

15 181 18/02/2012 N/A Supply Manpower for Installation NDB at Bekok A and BEC 2, Sdn /03/2012 N/A To Supply Insdustry Welding Socket and Compelete installation at PHI/PH2 Station Room at Stesen Janaelektrik Sultan Ismail, Paka, Terengganu 150, /04/2012 N/A Power Supply, PSP , Meanwell, Input 1, Sdn Sdn /05/2012 N/A The Installation Of Electronic Sounder and Strobe light at Warehouse 19, Yard A & B 26, Sdn /03/ Months To Supply Industry Welding Socket and Complete Installation at PH1/PH2 Station Room at Stesen Janaelektrik Sultan Ismail, Paka, Terengganu 150, Tenaga Nasional /09/ Months 187 5/04/2012 N/A Provision To Suply and Install Pulley for Low Voltage Explosion Proof Motor at GPPA 59, Supply of 2 Units Power Supply PSP & PSP Meanwell FPSO Bunga Kertas 1, Gas Berhad /01/ Weeks Provision of Riggers, Scaffolding, Equipment, Tools and Consumables for The Installation of Replacement Manuli Hose for FSO Cendor 40, Sdn /02/2013 N/A Electrical Cablings, Universal Joint CCTV Colour Camere 3, Sdn /03/2013 N/A /04/2013 N/A /04/2013 N/A /04/2013 N/A Provision of Electric Motor Repair for Berantai Operation 2, Rewinding and Services FWD Fire Pump Motor for FSO Abu Cluster Relays, Voltage Lamps & Lightings, Lamp Lamps & Lighting, Ballast Switching & Controlling, Transformer Electrical, Cablings, Plug for FSO Abu Cluster 9, , Provision Of Electrical and Instrumentation Works for Cendor MOPU Water Injection Debottlenecking 337, Sdn Sdn Sdn Sdn 194 Feb/2104 N/A Calibration Work Activity for Erb West & Kinarut 195 Feb/2014 N/A Repair and Recalibrate GMR SR March/2014 N/A Calibration Work Activity for Samarang 197 March/2014 N/A Calibration Work Activity for Sumandak 82, , , , Sabah Operation - Sabah Operation - Sabah Operation - Sabah Operation 15

16 198 March/2014 N/A Calibration Work Activity for SBGAST 199 April 2014 N/A Installation of MVTU12 at SBGAST 200 April/2014 N/A ACB Calibration at LGAST 201 Mei 2014 N/A Relay Calibration at LGAST 202 Jun 2014 N/A Relay Calibration at LGAST (Booster Comp. Area) 7, , , , , Sabah Operation - Sabah Operation - Sabah Operation - Sabah Operation - Sabah Operation 16

17 ELECTRICAL : SERVICE & REPAIR LV/HV MOTORS NO START DATE PROJECT DURATION BRIEF SCOPE VALUE (RM) CLIENT 1 19/05/04 2 Weeks 2 4/8/ Weeks To Repair / Service 6.6KV / 410KW Electric Motor (Manuf/Brand:Weir Pumps Ltd) (SN: ) To Rewind & Repair One Unit 10HP 'Toshiba Electric Motor 165, , /9/ Weeks To Refurbish Condenser Motor fm Tiong A 1, /08/ Weeks To Rewind / Service Motor MOL 8, /09/ Weeks To Service 30HP Cooler Fan Motor Fm Pulai A 5, /08/ Weeks 7 25/8/ Weeks To Rectify Motor End Play 250HP Electric Motor from Tinggi A Platform To Rewind / Repair One Unit 20HP 'Baldor' Electric Motor 8, , /08/ Weeks To Fabricate Fan Blade for Motor from Bekok C 12, /10/ Weeks MMC Tape For Sirim Certification 1, /10/ Weeks To Service and Certify MMC Tape 1, /9/ Weeks To Rewind / Repair One Unit 7.5KW 'Hansen' Electric Motor Gearbox 2, /09/ Weeks To Refurbish Spar Mixer Motor fm Dulang B 1, /10/ Weeks To Rewind / Repair Electric Motor fm Dulang B 2, /10/ Weeks To Refurbish Electric Motor fm Dulang B 2, /09/ Weeks 16 14/10/ Weeks 17 24/10/ Weeks 18 05/10/ Weeks To Repair Electric Motor Gas Cooler Fan 'Marelli' Motor from Duyong To Rewind / Repair One Unit 1/2HP Motor from MASA To Supply of MCT Materials & Cable Ladder for Duyong Platform To Refurbish Electric Motor fm Dulang B Platform 3, , , , /10/ Weeks To Repair Electric Motor Gas Cooler Fan 7, /10/ Weeks To Refurbish Electric Motor 3,

18 21 04/11/04 1 Weeks To Refurbish Electric motor From Dulang B 1, /11/ Weeks To Refurbish One Unit 4Kw / 3 Phase 3, /10/ Weeks To Repair and Service Electric Motor for Duyong Platform 5, /10/ Weeks To Refurbish Electric Motor for Dulang B Platform 5, /10/ Weeks To Refurbish Electric Motor for Dulang B Platform 2, /10/ Weeks To Service 300HP MOL Electric Motor 15, /10/ Weeks To Refurbish Shorted Electric Motor from Tiong A 1, /10/ Weeks To Rectify Motor High Vibration 7, /10/ Weeks 30 22/12/ Weeks To Refurbish One Unit 300HP U.S Electric Motor To Refurbish 'LOHOR' Electric Motor One Unit 4000KW 14, , /01/ Weeks To Supply Denyo AVR to Pulai A 5, /12/ Weeks 33 14/12/ Weeks 34 19/01/ Weeks To Refurbish Electric Motor from Duyong Platform To Repair and Rewind Lube Oil Cooler from Tiong A Platform To Repair and Service Electric Motor from Dulang B Platform 1, , , /02/ Weeks MMC Tape For Sirim Certification 1, /02/ Weeks To Repair One Unit 125HP Electric Motor from Bekok A 7, /03/ Weeks To Repair and Service Fan Motor from FPBK 1, /01/ Weeks To Repair Motor P160A from Tiong A 20, /03/05 1 Weeks To Rewind Step Down Transformer from Dulang D 1, /03./5 1 Weeks To Inspect and Calibrate Por GD fm FPBK 1,

19 41 13/03/ Weeks 42 21/02/05 1 Weeks 43 23/02/ Weeks 44 06/04/ Weeks 45 20/04/005 2 Weeks 46 10/04/ Weeks 47 05/04/ Weeks 48 29/03/ Weeks To Rewinding Vent Fan Electrical Motor for FSO Platform To Repair / Replace 2 units Sony TV from Dulang B Platform To Service and Certify MMC Tape to Bunga Kertas Platform To Repair Fan Motor Malfunction from Pulai A Platform To Service and Repair 250HP Electric Motor from Tinggi A Platform To Refurbish Electric Motor from Dulang B Platform To Repair Lube Oil Cooler Fan Motor from Bekok C Platform To Service and Rewinding Motor from Tiong A Platform 3, , , , , , , , /01/ Weeks To Repair Static Inverter from Duyong Platform 2, /04/ Weeks 51 23/05/ Weeks 52 24/04/ Weeks 53 22/02/ Weeks 54 28/0/ Weeks /04./ Weeks / Weeks Weeks To Fabricate Heater Element from FPBK Platfrom To Repair Baldor Electric Motor from Pulai A Platfrom To repair and Service Motor from Resak Platform To Repair One Unit US Electric Motor from Bekok C Platform To Overhaul Motor and Compressor from Dulang B Platform To Rewind Electric Motor from Dulang B Platform To Rewind Electric Motor from Dulang B Platform To Rewind Electric Motor from Dulang B Platform 9, , , , , , , , /06/ Weeks MMC Tape For Sirim Certification 1, /06/ Weeks MMC Tape For Sirim Certification 1, /03./005 1 Weeks To Repair and Service Induction Motor for Dulang B Platform 5,

20 61 07/03/ Weeks To Replace Bearing / Service Winding for Bekok C Platform 2, /06/ Weeks To Refurbish One Unit FLYGT Electric Motor for Dulang Platform 8, /06/ Weeks To Repair One Unit FLYGT Electric Motor to Dulang Platform 8, /06/ Weeks To Sent MOV Motor for Repair to Angsi A Platform 2, /05/ Weeks To Refusbish Electric Motor to Dulang B 8, /06/ Weeks To Refusbish Electric Motor to Tinggi 3, /05/ Weeks To Repair Ice Cream Machine to Angsi 10, /06/ Weeks To Repair MOL Pump Motor to Tiong 15, /08/ Weeks To Repair and Aligment Shaft for Electric Motor to Duyong 15, /08/ Weeks To Service and Repair Hydraulic ST 8, /08/ Weeks To Repair Faulty Infra Red Thermometer for Resak 6, /08/ Weeks To Fabricate Fan Blade I/Oil Cooler 3, /08/ Weeks ORR To Repair Motor's End Cover Bearing to FSO 1, /08/ Weeks To Rewind Motor,Bulk Fan to Bekok Platform 2, /08/ Weeks Sirim Certificate To Hydrometer and Thermometer 2, /08/ Weeks To Service Motor I/Oil Cooler 3, /08/ Weeks To Repair Motor Terminal Shorted to Pulai Platform 3, /09/ Weeks To Rewind Electric Motor Cooler Fan DDPA to Duyong Platform 6, /08/ Weeks To Refurbish Glycol Cooler Motor to Pulai Platform 2, /08/ Weeks To Rectify Motor Malfunction to Tiong Platform 2,

21 Weeks To Repair Electric Motor Wenstinghouse to Tiong Platform 2, Weeks To Repair Air Cond Motor 3, Weeks Weeks Weeks (ORR) Electric Motor shaft Wormout to Pulai Platform (ORR) To Refurbish Glycol Cooler Motor to Pulai Platform (ORR) To Rewind Electric Motor to Dulang Platform 7, , , Weeks (ORR) To Resize Motor Shafts as per Actual 7, Weeks (ORR) To Refurbish Motor Bearing 7, Weeks To Repair Microwave Oven from Angsi Platform 3, Weeks 90 08/12/ Weeks 91 08/12/ Weeks 92 08/12/ Weeks 93 08/12/ Weeks 94 08/12/ Weeks 95 03/03/ Weeks 96 11/09/ Weeks (ORR) To Repair SONY TV 21" from Dulang B Platform To Repair One Unit93HP Electric Motor to Tiong Platform (ORR) To Repair and Refurbish P-810B Motor to Tinggi Repair Electric Motor for Test Cooler for M114B to Duyong Platform (ORR) To Rectify Malfunction Electric Motor to Bekok A Platform To Repair One Unit Electric Motor X-DDPc M121C (ORR) To Refurbish Steam Cleaner Machine to Dulang B (ORR) To Rectify Bearing Oil Leak at Tiong Platform 1, , , , , , , , /10/ weeks To Repair and Service Electric Motor at Duyong 6, /02/ Week Service of Lube Oil Motor of Turbine Generator at Bekok C 4, /03/ Weeks Servicing of Electrical Motor for Cooling Fan Drive at Resak 3, /07/ Weeks To Inspect and Rectify The Electric Motor at Dulang 4,

22 101 27/09/ weeks /11/ Weeks /12/ Weeks To Rewind the ACB Charging Motor for Dulang A Platform To Repair and Service Cooling Fan Motor at Pulai A To Repair / Rewinding C-520 Air Compressor Motor Shorted at Pulai A 11, , , /12/ Weeks Repair Of Cooler Fan Motor at Resak 2, /02/ Weeks /03/ Weeks /04/ Weeks Provision To Rewind, Repair and Refurbish 3 Nos Of Electric Motor at Angsi To Repair / Service and Function Test Of 1 Unit Soft Starter MOL Pump P-160B at Tiong A To Rewind 2 Burnt AC Motor and Procure 1 DC Motor 5, , , /06/ Weeks To Repair Glycol Motor at Dulang 6, /06/ Weeks To Repair Electric Motors and Hot Oil Pump 8, /06/ Weeks /06/ Weeks /07/ Weeks To Repair winding Motor Shorted EL-WD-F186 at Dulang To Service / Repair Motor CTO P870C at Bekok C To Repair and Service Electric Motor for TG360A 2, , , /07/ Weeks Motor Starter For Water Treatment at Pulai A 204, /08/ Weeks To Repair and Service Sea Water Lift Pump Motor at Pulai A 52, /08/ Weeks New Motor Bearing for P470A 15, /08/ Weeks /08/ Weeks /09/ Weeks /09/ Weeks To Repair and Service Discharge Cooler Fan Motor HX-1004B at TCOT To Repair and Service Electric Motor For Main Oil Line Pump To Repair and Service Suction Cooler Motor HX1001A at TCOT To Repair and Service Discharge Cooler Fan Motor HX-1004A at TCOT 4, , , , /09/ Weeks To Repair and Service Motor Lube Oil Cooler 5,

23 121 22/09/ Weeks To Service/Repair Washing Machine Motor at Bekok C 4, /09/ Weeks To Service P600B Hot Oil Circulation Motor at TCOT 17, /09/ Weeks To Repair Condenser Sea Water Lift Pump and Caisson Pump Motor at Dulang 106, /11/ Weeks To Service / Repair Motor - 20hx682a at Bekok C 4, /12/ Weeks Repair and Service Motor For MOL Pumo P- 165A at Pulai A 21, /12/ Weeks To Repair and Service Motor for ME744D at Tinggi 3, /12/ Weeks To Repair and Service Produced Water Skimmer Motor P525B at TCOT 13, /01/ Weeks To Repair and Service Exhaust Fan Motor to TCOT 1, /01/ Weeks To Repair and Service Motor MOV 286C to TCOT 2, /01/ Weeks To Repair and Service Cooling Fan Motor P 5151B at TCOT 4, /01/ Weeks To Repair and Service Cooling Fan Motor P5156B at OSC 1, /01/ Weeks To Repair and Service Motor For Crude Oil Booster Pump P-120 at Pulai A 24, /04/ Weeks To Rewind Motor shorted For Water Maker 10, /06/ Weeks To Rectify and Service 2 Nos of Electric Motors at Dulang B 4, /06/ Weeks To Service P 5473 Fire Water Duty Motor at OSC 26, /06/ Weeks Vacuum Motor Repair at Angsi 10, /07/ Weeks To Service P 290B Slop Oil Transfer Pump at TCOT 28, /07/ Weeks To Service P-470B Crude Oil Booster Motor at TCOT 66, /07/ Weeks To Repair and Service Motor MOV 210D at TCOT 1, /07/ Weeks To Repair and Service Motor MOV 289A at TCOT 1,

24 141 28/07/ Weeks To Repair and Service Motor MOV 416 at TCOT 6, /09/ Weeks /09/ Weeks /09/ Weeks To Service / Repair Motor Portable Water Pump at Bekok C 7, To Service / Repair Motor CTP P870B at Bekok C 17, To Service / Repair Electric Motor P 623B at Bekok C 1, /10/ Weeks To Service Electrical Motor For Duyong /10/ Weeks /10/ Weeks 56, To Repair and Service Flare Blower Motor B500C at TCOT 6, To Repair and Service C 270B Cooloer Motor at TCOT 3, /10/ Weeks Water Injection motor P4040C Refurbishment - To Refurbishment the WI Motor its Pheripherals at Angsi 306, /11/ Weeks To Repair/Service Generator G620 Stator/Rotor Exciter & AVR at TCOT 53, /11/ Weeks To Repair Electrical Motor at Dulang /11/ Weeks /11/ Weeks /11/ Weeks 2, To Purchase Power Plug For Grundfos Motors at Dulang 26, To Refurbish Motor, Replace Bearings and Perform Motor Shaft balancing at Tingi 10, To Rewind Motor Shorted For Cooler Fan Motor at Bekok A 3, /12/ Weeks To Service One Unit CTP - C Motor at BEC /12/ Weeks /12/ Weeks /12/ Weeks /12/ Weeks /12/ Weeks /12/ Weeks 7, To Repair 2 Nos CTP Motor Leg/Mounting Cracked/Broken at Bekok C 24, To Rewind and Service Electrical Motor for Duyong 13, Repair of Faulty Cooler Fan Motor for Air Compressor at Pulai A 12, To Repair and Service Air Blast Oil Cooler Fan Motor P380B To Repair & Service Condensate Recovery Booster Motor P5531 at OSC To Repair and Service Separatior Bottom Motor P230A at TCOT 8, , , /10/ Weeks Provision of refurbishment One (1) Unit Electric Motor P 520B at TCOT for - PMO 4, PCSB 24

25 ELECTRICAL : RELAY CALIBRATION & THERMOGRAFHY WORKS NO START DATE CONTRACT DURATION BRIEF SCOPE VALUE (RM) CLIENT 1 27/05/ weeks 2 15/06/ Week Relay Calibration at Bekok-A, Tiong-A, Tinggi-A and Pulai-A Platform 159, Testing and Calibration of Electrical Protective Relays and Breakers for Angsi Platform 169, /03/ weeks 4 13/09/ Week 5 18/01/ Week 6 10/05/ Weeks 7 2/8/ weeks Provision for Supply of Manpower, Tools & Equipment for Testing and Calibration of Electrical Protective Relays & Breakers for Resak Platform Relay Calibration & Breaker service at Dulang Field Relay Calibration & Breaker Service at Bekok A & C Platforms Repair and Services of 3 units of Multilin Relays SR469 and 5 units of MM2 Relays from Angsi A To Do Gas Turbine Relay Calibration at Tinggi A Platform 120, , , , , /03/ Weeks Recalibration of 4 unit SR 489 GE-Multilin & 4 unit Vaccum Circuit Breaker at Angsi Platform 71, /05/ Weeks Relay Calibration at All Duyong Platforms 41, /08/ weeks Relay Calibration (2007) at Resak 106, /07/ Week To Conduct Relay Calibration on HV & LV Switchgear at OGT 23, /07/ Weeks Relay Calibration at All Dulang Platforms 71, /07/ weeks 14 29/1/ Weeks 15 25/02/ Weeks 16 25/05/ Week /06/ /07/ Weeks 1 Weeks To Perform Relay Calibration for HV Relay at Angsi A Provision to Refurbish of SR750 Feeder Relay for Pulai-A Provision To Repair 6 Nos of MMII Relay at Angsi Relay Calibration On Turbine Generator at Bekok C Provision To Repair 7 Nos of MMII Relay at Angsi Conduct Thermography Inspection On Electrical Equipment at Pulai, Tiong A-B and Kepong Field 119, , , , , , /07/ Week Thermography Test at MASA Platform 70, /07/ Week Conduct Thermography Inspection On Electrical Equipment at OGT / TCOT / OSC 11,

26 21 16/09/ Week Thermography Test at Dulang 22, /9/ Weeks Supply Manpower & Test Equipment for Relay Calibration at Angsi 512, /11/ Week Thermography at Bekok A, Bekok B and Bekok C (PM-Checks/Verify SWGR and Bussbar) 28, /11/ Week Thermography at Bekok C 12, /05/ Week Installation Earth Fault Relay and Reverse Power Relay at Dulang 13, /05/ Weeks Relay Calibration at Abu Platform 187, /05/ Weeks Relay Calibration and Main Breaker Service at Duyong Platform 77, /05/ Week To Conduct Relay Calibration on LV Switchgear at Tiong A 47, /09/ Weeks Relay Calibration at Dulang 76, /09/ Week To Perform Thermography For For All Electrical Equipment at OGT 11, /09/ Week Relay Calibration at OGT 62, /09/ Weeks Conduct Yearly Thermography Activity for Bekok A and Bekok B & Bekok C 17, /12/ Weeks To Conduct Thermography on HV/LV Switchgear, UPS/Charger at TCOT 40, /09/ Month Motor & MCC Service and Relay Calibration 15, PGB CUFK 26

27 ELECTRICAL : SUPPLY BULK MATERIAL NO START DATE CONTRACT DURATION BRIEF SCOPE VALUE (RM) CLIENT 1 15/1/2004 N/A To Supply of Surge Suppressor and Rotating Diode for G420 at Pulai A 3, /02/2004 N/A To supply transfomer for Auto-Transfer Switch and MCCB (ABB or equal) 5, /4/2004 N/A Supply of ATS Transformer 7, Engineering 3 07/08/2004 N/A To Supply of Micromate UPS 2000E for Bekok- C Platfrom 42, /08/04 N/A To supply of 4 unit Circuit Breaker for Air- Compressor at Bekok-C Platform 10, /11/2004 N/A Supply Power Cable 600/1000V to IEC332 XLPE/PVC/SWA/PVC 2, /03/2005 N/A To supply of Surge Supressor to Pulai A Platform 9, /09/2005 N/A 7 25/10/2005 N/A 8 18/01/2006 N/A 9 24/01/2006 N/A 10 02/02/2006 N/A Supply of 1 New Unit 3200A ACB for Pulai A Platform (Supply of Westinghouse at Pulai A) Supply of Motor Protection Relay for Dulang B Booster Pump Supply of Electronic Transformer for Helideck Primeter Lighting at Bekok C To Supply of 6 Unit Current Transformer for Dulang B Platform Supply of 110 VDC Portable Charger for Turbine Generator at Resak Platform 161, , , , , /04/2006 N/A To Supply EXD Enclosure c/w Transformer 11, /11/2006 N/A Supply 240 Volt To Cater Existing Load at Tinggi A Platform 69, /12/2006 N/A Variation Order -1 for Duyong CPP TG Motor Starter Installation Works - Breakers 12, Installation 14 24/12/2006 N/A Variation Order -1 for Duyong CPP TG Motor Starter Installation Works - Breakers 6, Installation 15 07/02/2007 N/A To Order Motor Starter for Portable Air Compressor at Bekok C 18, /03/2007 N/A Supply of Instrument and Electrical Materials for Resak - Liquid Handling Project at Resak 55, Platform 17 21/03/2007 N/A Supply of Materials for New Pumps Installation at Resak-CPP LPKO Drum at Resak Platform 35, /05/2007 N/A Supply of E & I Materials For New Air Compressor at Resak 167, /08/2007 N/A Supply of Additional Electrical at Resak CPP 518, /08/2007 N/A Supply Portable Air Compressor for FSO Puteri Dulang 24,

28 21 16/08/2007 N/A Variation Order To Install JB & Socket and Lighting at Mustering Station at OGT 13, /08/2007 N/A Variation Order To Repair Faulty Underground Cable #P-0012 at OGT - Shunt Trip 19, /08/2007 N/A Purchase of Partial Stroke Material for Dulang 26, /12/2007 N/A To Supply Rental Air Compressor at FSO 39, /01/2008 N/A Provide Rental Generator To Install 2 unit ACB on shutdown Activity at Pulai A 80, /2/ Weeks Supply Beacon Light for Vehicle /03/2008 N/A To Supply One MCCB at Tiong A 10, /03/2008 N/A 28 25/05/2008 N/A 29 06/05/2008 N/A To Purchase One Unit Fan Motor 16" for Chiller Fan Motor at BEC To Supply Electrical Power at Guard House at OGT Park To Supply One Unit Motor, 480 Vac, 60HZ, 3 Phase for Walk In Freezer (freezer Compressor) at Tiong A 10, , , /07/2008 N/A Supply Of Rental Air Compressor for Anding 12, /08/2008 N/A Rental Air Dryer at TCOT 47, /08/2008 N/A Rental Air Dyrer at OSC 42, /08/2008 N/A 34 25/08/2008 N/A 35 10/10/2008 N/A 36 17/11/2008 N/A 37 25/11/2008 N/A 38 12/10/2008 N/A 39 07/06/2009 N/A 40 16/09/2009 N/A 41 11/11/2009 N/A Provision To Supply Competent Manpower to Install 60 Cell Batteries for Air Compressor at Pulai A 10, Supply of Extra Materials and Consumables for New Flowlines Installation 13, Rental of 80KW / 100KVA Diesel Genset at Sotong (MASA) 110, Procure and Supply Of Electrical Materials for Air Compressor and Air Dryer at OGT 118, To Purchase Electrical Materials For LP Header Project at Dulang D 78, To Purchase Materials For Produced Water Treatment Upgrading at Pulai A 134, To Supply Spareparts for Net Oil analyser at Bekok C 135, To Purchase LCS for LP Header Motors at Dulang D 29, To Purchase Material for Cable Tray Replacement at Dulang B 82, /12/2009 N/A To Supply Power Cable for Duyong 43 25/02/2010 N/A TGA Well A7 Workover Project at Tinggi A - ADDITIONAL MATERIAL 74, , /06/2011 N/A Process Fan, RDH355R CW 90, NICORTRA 5, Supply of 2 Units Power Supply PSP & 45 5/04/2012 N/A PSP Meanwell FPSO Bunga Kertas 1, FPSO VENTURES 28

29 45 Feb/2104 N/A Supply of Altshom Relay - MVTU12 4, Carigali - Sabah Operation 46 March/2014 N/A Supply new GMR SR489 37, Sabah Operation 47 Mei/2014 N/A Supply and Install of New Relay for Replacement MVTU 11 & 12 at SBGAST 32, Sabah Operation 29

30 CURRENT INSTRUMENT PROJECT NO START DATE BRIEF SCOPE VALUE (RM) CLIENT 1 10/02/2014 Suplly Instrument Part For Saltelite Improvement (3rd Batch) 11, /03/2014 Supply Spare Yokogawa Transmitter For Saa 17, /06/2014 To Rental Of Id Printer For Boa /06/2014 To Rental Of Id Printer For Boa /06/2014 Supply Of Dpgauge For Satelite Improvement 72, /07/2014 Supply Of Orifice Plate For Bra 27, /06/ /07/2014 Supply Of Spare Float For Magnetic Level Gauge For Bra 1st Stage Separator Supply New Pressure Transmitter For Brb Fso Crude Oil Export 13, , /08/2014 Supply New Pressure Transmitter For Bra 5, /08/2014 Supply New Id Printer For Boa 54, /08/2014 Supply K-tek Level Gauge For Bre 36, /08/2014 Supply Actuator Power Module For Bre 54, /08/2014 Supply Magnetic Level Gauge For Bra 47, /08//2014 Src Gd & Supply Tyco Avid Positioner, Smartcal, Oracle Ref For Bre 30, /07/2014 Service And Supply New Orbisphere Parts 65, /08/2014 Supply Restriction Orifice Plate For Bra 3, /09/2014 Supply New Neo Dyn 29, /09/2014 Supply New Orifice Plate 10, /09/2014 Calibrate Weighing Machine 3, /07/2014 Rental Scaffolding & Manpower For Dulang Shutdown ,

31 21 10/07/14 Rental Scaffolding & Manpower For Dulang Shutdown , /07/14 Mobilize Manpower For Gas Detector Pole Installation Work At Tiong A 81, /07/14 Mobilize Manpower For Cable & Tubing Replacement Work At Pulai & Ledang 2, /08/14 Supply Scaffolder & Scaffolding Material & Cargo Basket For Angsi August Shutdown 69, /08/14 Recertification MMC Gauging Tape For Fso Sepat 1, /09/14 Supply 2 Pax Technician For Cable Laying Work At North Lukut & Abu Platform 7, Dagangan Kerteh 27 13/07/2014 To Supply Maritim Distress Signal 1, Sdn 28 12/08/2014 To Supply Instrument Tools, TK-3G 96, Sdn 29 19/8/2014 Service,Repair & Rewinding 2 unit Motor 13, Sdn 30 18/8/2014 Upgrading Fusible Tube To Linear Heat 61, Sdn 31 28/08/2014 Rental Of Scaffolding and Scaffolder for FPSO Abu Cluster /08/14 JB Replacement At PCSB RESAK 137, /08/14 Supply HVAC,ACCU Compressor 4, Sdn Sdn 31

32 COMPLETED PROJECT : INSTRUMENT INSTRUMENT : INSTALLATION & MAINTENANCE WORKS NO START DATE CONTRACT DURATION BRIEF SCOPE VALUE (RM) CLIENT CUSTOMER 1 4/2/ weeks Installation of Dissolved Oxygen On-Line Analyzer at Boiler Feed Water System at GPP 2, 3, 4 96, Emerson Process Management Gas Berhad 2 1/3/ weeks Cabling works for new Moisture Analyzer at GPP 2, 3 & 4 26, Nusa Armada Gas Berhad 3 21/04/ Weeks To Supervise Works on Moisture Analyser Installation & Commissioning 5, Engineering 4 28/04/ weeks Supply of manpower and equipment to Perform Intergrity Check On hyraullic System for Malong & Sotong acutated Choke Valves, modification of PLC/MMI programming and to perform functional tests on modified systems. 49, Engineering 5 29/04/ weeks To Service & Calibrate 5 nos of Hydrometer & 2 nos of Thermometer 4, Engineering 6 9/5/ weeks Fusible Plug Loop Tubing at DPP- A 141, Engineering 7 5/6/ weeks E&I Top Side Maintenance Contract Supply of Manpower, Material, Equipment & Consumables for Fusible Plug Loop Replacement at Duyong-A Platform 141, Engineering 8 8/8/ Weeks To relocate PIC at Bekok - C 24, Engineering 9 12/8/ Weeks Installation of Coriolis Meters at Malong & Sotong 5, Engineering 10 20/10/ Weeks To conduct Site Visit on A6 Flowline Installation at Penara Platform 30, Engineering 32

B. Section Transfer Switches: Automatic transfer switch.

B. Section Transfer Switches: Automatic transfer switch. SECTION 263213 - ENGINE GENERATORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Packaged engine generator set. B. Exhaust silencer and fittings. C. Remote control panel. D. Battery and charger. E. Weatherproof

More information

PROFILE. industrial services rental trading

PROFILE. industrial services rental trading PROFILE industrial services rental trading Introduction Power Corp General Trading & Contracting Company W.L.L. is incorporated by technocrats having vast experience in Engineering and Construction field

More information

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets 2 X 1996 Wartsila 18V26 5.125mw Each 50hz HFO Generator Sets The responsibility for any and all additional charges is the purchasers. 2 x WARTSILA 5 MW Power plant 2 Units of Wartsila 18V26 @ 5 MW each,

More information

one stop HVACR OEM MANUFACTURER PROJECT REFERENCE

one stop HVACR OEM MANUFACTURER PROJECT REFERENCE one stop HVACR OEM MANUFACTURER PROJECT REFERENCE The Company PMT is an OEM manufacturing company for HVACR equipments and parts. Spread over 22,000 square-meter of manufacturing facility and operate by

More information

COMPANY PROFILE Electrical & Instrumentation Contractor

COMPANY PROFILE Electrical & Instrumentation Contractor COMPANY PROFILE Electrical & Instrumentation Contractor Engineering I Supply I Installation I Testing I Commissioning Maintenance I Fabrication I Ship Repairing ABOUT US The year was 2003, where there

More information

Prefunctional Checklist

Prefunctional Checklist Prefunctional Checklist This Prefunctional Checklist should be completed as part of startup and initial checkout of the equipment in preparation for Functional Performance testing. PC: 16231 ITEM: Generator

More information

ENGINE GENERATORS AND ACCESSORIES

ENGINE GENERATORS AND ACCESSORIES ENGINE GENERATORS AND ACCESSORIES GENERAL INFORMATION 1.1 This section applies to engine generators and accessories. DESIGN REQUIREMENTS 2.1 The Engineer of Record will consult with the University s Engineering

More information

Company PROFILE. Copyright 2017 Qasturi Network Solutions. All rights reserved. Sufian Latib

Company PROFILE. Copyright 2017 Qasturi Network Solutions. All rights reserved. Sufian Latib Company PROFILE Sufian Latib INTRODUCING Qasturi Network Solutions Qasturi Network Solutions is operates by experienced Automation Engineer and entrepreneur based in Pasir Gudang,Johor Malaysia. Qasturi

More information

Appendix B9 Geothermal Unit Cause Codes

Appendix B9 Geothermal Unit Cause Codes Appendix B9 Geothermal Unit Cause Codes GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Unit Codes 800 899) Cause Code BOILER Ranges Page No. Boiler Piping System 0500-0620 B-GE-2 BALANCE OF PLANT

More information

TECHNICAL SERVICES DIVISION

TECHNICAL SERVICES DIVISION TECHNICAL SERVICES DIVISION Electrical and Instrumentation new construction, installations, repairs & upgrades, and maintenance services Panel Design & Manufacturing electro/pneumatic, generator/control,

More information

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input April 2006 SCR-SCRF Utility & General Industry Switchgear Alarm Systems Engine Starting Railroad Emergency

More information

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES Boiler Piping System 0500-0620 Condensing System 3110-3199 Circulating Water Systems 3210-3285 Waste Water (zero discharge) 3290-3299 Condensate

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38 BR 54/ NATIONAL OCCUPATIONAL CERTIFICATION ACT 2004 2004 :38 The National Training Board, with the approval of the Minister responsible for the National Training Board, in exercise of the powers conferred

More information

Automations Controls Experts

Automations Controls Experts ACE Instrumentation Automations Controls Experts ABOUT US ACE Instrumentation is renowned as one of the best marine automation company in Singapore. Our offices are located conveniently near shipyards

More information

31.05/ Unit-1

31.05/ Unit-1 Semi-Annual Inspection FS Report 31.05/02.06.2015 Unit-1 Customer Representative: GE Field Service Representative: All technical recommendations and information contained in this report are based on GE

More information

TRANS ATLANTIC TRADING ENTERPRISE INC.

TRANS ATLANTIC TRADING ENTERPRISE INC. TA GLOBAL SOLUTIONS INDUSTRIAL COMMERCIAL RESIDENTIAL AUTOMATION +1 (416) 317-3325 +1 (647) 294-2594 www.transatinc.com info@transatinc.com ELECTRICAL BUSWAY DISTRIBUTION EQUIPMENT TRANSFORMERS CIRCUIT

More information

UEE30811 Q-Tracker Work Tasks

UEE30811 Q-Tracker Work Tasks UEE30811 Q-Tracker Work Tasks UEENEEC020B Participate in electrical work and competency development activities Q-Tracker requirements: 40 hours of practical training. 1. Comply with electrical industry/enterprise

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities

More information

Holds a B. Sc. in Electronics & Communication Engineering and has over 8 years hands-on experience working in I&C field.

Holds a B. Sc. in Electronics & Communication Engineering and has over 8 years hands-on experience working in I&C field. 102740-ICX-CMOS-E-2007 I&C Engineer Holds a B. Sc. in Electronics & Communication Engineering and has over 8 years hands-on experience working in I&C field. PERSONAL DATA Nationality : Egyptian Birth Date

More information

SIGMA 3 ENGINEERING LIMITED

SIGMA 3 ENGINEERING LIMITED SIGMA 3 ENGINEERING LIMITED Sigma 3 is a multi-disciplined engineering consulting firm founded in 1989. Our prime objective is to provide engineering, project management, and commissioning services to

More information

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices Cold Weather Preparedness RF Criteria For Plant Visits: Generating facilities that experienced repeated freezing or cold weather

More information

AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS

AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS on behalf of the Cryogenics for Accelerator Group Accelerator Technology Department CERN, Geneva, Switzerland Outline Introduction Cryogenic systems layout

More information

Instrument Air Packages engineered for the desert and high temperature environements

Instrument Air Packages engineered for the desert and high temperature environements -5 C +55 C Instrument Air Packages engineered for the desert and high temperature environements Oil free and oil injected compressors and heatless dryers THE DETAILS MAKE THE DIFFERENCE DESIGNED FOR THE

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Experience: Electrical & Instrumentation

Experience: Electrical & Instrumentation Experience: Electrical & Instrumentation Part 1: Projects greater than US$1,000,000 Client Mozaik printing factory: Electrical fit out Supply and Installation of Main Distribution Panels, Distribution

More information

FLOAT BATTERY CHARGERS

FLOAT BATTERY CHARGERS FLOAT BATTERY CHARGERS UNFILTERED SCR SERIES FILTERED SCRF SERIES SINGLE PHASE INPUT THREE PHASE INPUT Applications for: UTILITY & GENERAL INDUSTRY Switchgear Engine Starting Emergency Lighting Alarm Systems

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Solutions for Oil & Gas

Solutions for Oil & Gas Solutions for Oil & Gas AUTOMATION & SMART SOLUTIONS FOR OIL & GAS Westcon Power & Automation have performed EIT responsibility for over 110 rig yard stay and a wide range of projects offshore. Our commitment

More information

Deaerator. Specifications

Deaerator. Specifications ESI, INC. OF TENNESSEE RENTAL EQUIPMENT Deaerator Description The deaerator, built in 1996, is a spray-type deaerating feedwater heater and storage tank with stainless steel internals. The deaerator is

More information

Unit Concept (M) Sdn Bhd

Unit Concept (M) Sdn Bhd (M) Sdn Bhd 1 Chemtech Oiltek Plant Process Control System Specialty Fats Plant, scope of supply includes: Design, installation, and commissioning of the process control system, instrumentation, transmitter,

More information

650-EL-C-E-1995 Senior Electrical Engineer. PERSONAL DATA Nationality : Egyptian Birth Date : 06/01/1969 Marital Status : Married

650-EL-C-E-1995 Senior Electrical Engineer. PERSONAL DATA Nationality : Egyptian Birth Date : 06/01/1969 Marital Status : Married 650-EL-C-E-1995 Senior Electrical Engineer Holds a B. Sc. in Electrical Engineering and has about 16 years experience in the field of electrical construction, pre-commissioning and follow up activities

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

FDF Foam Pump Controllers Features

FDF Foam Pump Controllers Features FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for

More information

DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 ( TPH) COLD AGGREGATE FEEDER.

DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 ( TPH) COLD AGGREGATE FEEDER. DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 (90-120 TPH) ROAD BUILDING COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is with each

More information

Operating Cost Metrics. Willem van Es St Andrews 2016

Operating Cost Metrics. Willem van Es St Andrews 2016 Operating Cost Metrics Willem van Es St Andrews 16 Operating Cost Metrics Maintenance experience POB experience Legend Bases for Inspection & Maintenance Strategy Health (Present, Future) Safety (Present,

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

Holds a B. Sc. in Communications & Electronics Engineering and has about 11 years hands-on experience working in I&C field.

Holds a B. Sc. in Communications & Electronics Engineering and has about 11 years hands-on experience working in I&C field. 102866-ICX-CMOS-E-2005 Lead I&C Commissioning / Maintenance Engineer Holds a B. Sc. in Communications & Electronics Engineering and has about 11 years hands-on experience working in I&C field. PERSONAL

More information

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE COMPANY PROFILE We are a Customized Engineering Solution Provider in the field of Industrial & Spec Gases WHO operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial

More information

Contractor Worksheet Underground Fires Major Hazard Standard

Contractor Worksheet Underground Fires Major Hazard Standard WMC Environment, Health & Safety Management System Worksheet Major Hazard Standard MHS-02 DocsOpen Ref: 57267, 17/10/2001 Uncontrolled copy check web for latest revision Revision Reviewed Description of

More information

Technical Data Submittal Documents

Technical Data Submittal Documents Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Documents Model PD - FM Diesel Engine Driven Fire Pump Controller Contents: Data Sheets Dimensional Data Wiring Schematics Field

More information

MITSUBISHI AIR-CON SPARES TD43C/TD43D/TD60

MITSUBISHI AIR-CON SPARES TD43C/TD43D/TD60 Page 1 of 5 MITSUBISHI AIR-CON SPARES TD43C/TD43D/TD60 1 COMPRESSOR - TK 315R (TUBE-O) 102-0810 2 CLUTCH - ASSEMBLY (24V,2B PULLEY,TK) 107-0327 3 FLANGE - COMPRESSOR 22-1176 4 CONNECTOR - DISCHARGE (TUBE-O)

More information

POWER GENySYS P ROJECT E XPERIENCE I NFORMATION - D ISTRIBUTED G ENERATION

POWER GENySYS P ROJECT E XPERIENCE I NFORMATION - D ISTRIBUTED G ENERATION POWER GENySYS Burlington, Ontario. PORT COLBORNE GENERAL HOSPITAL Above: Entrance of,. 2 nd Hospital Cogeneration System in Ontario (1993) In 1993 Marsh Energy Inc. was awarded a turnkey contract by the

More information

TITLE: SPECIFICATION NO. PE-MSE-VD-ACC VOLUME:

TITLE: SPECIFICATION NO. PE-MSE-VD-ACC VOLUME: (For Vendor Registration Purpose) SHEET 1 of 6 1.00.00 GENERAL INFORMATION 1.01.00 The general guidelines as illustrated in the subsequent clauses of this section shall be applicable for air cooled condenser

More information

polar zone components and systems for extreme temperatures

polar zone components and systems for extreme temperatures polar zone components and systems for extreme temperatures 2 Our customers safety in their day-to-day work is the main focus of our business. The company has been working towards this for over 80 years

More information

266-CS-TMS-E-2008 Automation & Instrumentation Engineer. PERSONAL DATA Nationality : Egyptian Birth Date : 23/08/1986

266-CS-TMS-E-2008 Automation & Instrumentation Engineer. PERSONAL DATA Nationality : Egyptian Birth Date : 23/08/1986 266-CS-TMS-E-2008 Automation & Instrumentation Engineer Holds a B. Sc. in Industrial Electronics and Control Engineering and has about 3 years experience with deep understanding of Electrical Engineering,

More information

Letter from GM BASIL AL HANBALI

Letter from GM BASIL AL HANBALI 3 Letter from GM To embark on a journey of success one needs the tools of preparedness, foresight and strategy. These lead to the path of growth and high quality operation. It is imperative to combine

More information

Document Code: 1 (5) Issuing date: Status:

Document Code: 1 (5) Issuing date: Status: Document Code: 1 (5) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION MAIN CONDENSATE PUMPING Submitted for: Customer reference: Other information:

More information

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm) Heat Recovery Units AIR HANDLING UNIT No. SERVICE AREA MANUFACTURER MODEL HRU-3 & HRU-4 B-Section Low Rate Ventilation Tempeff RG 16000 (9500) SUPPLY FAN - SIZE/TYPE AIRFLOW RATE (cfm) (l/s) TOTAL STATIC

More information

MANNYBEL V. URDAS JR.

MANNYBEL V. URDAS JR. MANNYBEL V. URDAS JR. Personal Profile: Goal and results oriented person with a strong technical background and education.10 years of experience in electrical/instrumentation maintenance and construction,

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Innovation applied to Offshore Applications Well head analysis Process

More information

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

November 11, City of Sparks 215 S. 21 st St. Sparks, NV November 11, 2014 City of Sparks 215 S. 21 st St. Sparks, NV 89432-0857 Attn: Brian Cason Re: Sparks City Hall HVAC Upgrade Project-Alerton Direct Digital HVAC Control System to Match Existing City of

More information

Kube Engineering. Industry Guide. Power Industry

Kube Engineering. Industry Guide. Power Industry Industry Guide Power Industry 30298 Trois Valley Street Murrieta, CA 92563 951-926-0675 P 9951-926-2652 F Quinn@kubeengineering.com www.kubeengineering.com 1 Application Guide Analytical Locations Water

More information

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS ROAD BUILDING COLD AGGREGATE FEEDER 2 x 2 bin aggregate feeder unit is with total capacity of 20 T. Gathering cum slinger conveyor

More information

A2S s Company Profile

A2S s Company Profile A2S s Company Profile Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d installation Contrôle commande World Class Developer of Electrical Equipement for use in Hazardous Areas

More information

E-17 Flammable Gas Detection and Alarm System

E-17 Flammable Gas Detection and Alarm System Guideline No.E-17 (201705) E-17 Flammable Gas Detection and Alarm System Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,

More information

Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES SOLAR ENERGY GATHERING EQUIPMENT Solar Field 6500-6559 Thermal Storage 6570-6589 Operational Problems 6590-6599 STEAM TURBINE

More information

DELUXE COACH: Extended coach coverage. ULTRAMAX: Bumper to hitch plan.

DELUXE COACH: Extended coach coverage. ULTRAMAX: Bumper to hitch plan. 2 ULTIMATE PLANS covering you u Pick one that bes : Extended coach coverage. ULTRAMAX: Bumper to hitch plan. THESE PEACE OF MIND BENEFITS ARE INCLUDED ON ALL PLANS: ROADSIDE ASSISTANCE: Reimbursement shall

More information

Annexe: Width 9 mtrs (4+2), length 130 mtrs divided into following sections: Impulse Test Lab. Routine Test Lab. Stores. Works offices.

Annexe: Width 9 mtrs (4+2), length 130 mtrs divided into following sections: Impulse Test Lab. Routine Test Lab. Stores. Works offices. (Note: List of routine and General Machines and Equipments,Tools,Tackles, Small Testing Equipments etc. are not included).recent Expansion at our Yewat Work Land: Additional 50000 sq mts of land. Shed:

More information

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER. Gathering cum slinger conveyor 500 mm x 7.

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER. Gathering cum slinger conveyor 500 mm x 7. ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS ROAD BUILDING COLD AGGREGATE FEEDER 2 x 2 bin aggregate feeder unit is with total capacity of 20 T. Gathering cum slinger conveyor

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

Engineering Design & Testing Corp./EDT Engineers, P.C.

Engineering Design & Testing Corp./EDT Engineers, P.C. ENGINEER: ELECTRICAL ALBERT M. ROSE, P.E. Engineering Design & Testing Corp. Post Office Box 940520 Maitland, Florida 32794 Telephone: (407) 865-9900 amrose@edtengineers.com EDUCATION: 1981 Bachelor of

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

Hazardous Area Zirconia Oxygen Systems

Hazardous Area Zirconia Oxygen Systems Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation

More information

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

COMPANY PROFILE BUMI WANGSA SDN BHD

COMPANY PROFILE BUMI WANGSA SDN BHD COMPANY PROFILE BUMI WANGSA SDN BHD NO. 112, JALAN DAMAI, OFF JALAN AMPANG, 55000, KUALA LUMPUR, WILAYAH PERSEKUTUAN, MALAYSIA TELEPHONE: +6 03 2141 6566 FACSIMILE: +6 03-2148 3228/2144 2816 WEBSITE: WWW.BUMIWANGSA.COM.MY

More information

Size and rating wise typical Third Party Inspection certificates for the models of Valves

Size and rating wise typical Third Party Inspection certificates for the models of Valves For Item code star ting w i th 15 & 1 6 Control Valves: Supply references for valves supplies, for last three years, as per format A,B,C available in Annexure XVI (duly notarized/certified by statutory

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

Rental Boiler Specifications (Nebraska Boiler)

Rental Boiler Specifications (Nebraska Boiler) Rental Boiler Specifications (Nebraska Boiler) ESI's 72,000 pph trailer-mounted watertube steam boilers are designed and built in accordance with ASME Code. Each boiler is arranged for natural gas or #2

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Tender Document. MR 193/ Design, Supply & Commission New Control Panel for Ruston 16RK270 Generator

Tender Document. MR 193/ Design, Supply & Commission New Control Panel for Ruston 16RK270 Generator Tender Document MR 193/2017 - Design, Supply & Commission New Control Panel for Ruston 16RK270 Fiji Electricity Authority Generation 17-Jul-17 Tender Submission - Instruction to bidders It is mandatory

More information

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual VoCALL - CFVCC5 Compact 5 Line Exchange Unit Installation & Commissioning Manual Introduction A VoCALL Emergency Voice Communications System (EVCS) is a fixed, secure, bi-directional, full duplex voice

More information

Rules and Regulations for the Classification of a Floating Offshore Installation at a Fixed Location

Rules and Regulations for the Classification of a Floating Offshore Installation at a Fixed Location Rules and Regulations for the Classification of a Floating Offshore Installation at a Fixed Location Part 6 Control and Electrical Engineering June 2013 Lloyd s Register is a trading name of Lloyd s Register

More information

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT EXPLOSION PROTECTION Experts in Equipment for Explosive Atmospheres Ex SPECIALISTS TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT LIGHTING Portable, Temporary & Fittings Hazardous area lighting and

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013 Fuel Gas Systems Knowledge Objectives (1 of 2) Explain the impact of fuel gases on fire and explosion investigations. Discuss the characteristics of fuel gases. Identify common fuel gas system components.

More information

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F 5 6 HIGH-PRESSURE STEAM is routed from the wood-chp boiler to the turbine. TURBINE BLADES spin at nearly 00 revolutions per second. Steam acting on the turbine blades creates mechanical energy in the TURBINE.

More information

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION

More information

CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES

CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES CONTROLLED GOODS AND THE APPLICABLE SAFETY STANDARDS PART I DOMESTIC OR HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL APPLIANCES 1 Hair Dryers 8516.31 MS IEC 60335-2-23 Household and similar electrical appliances-

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,

More information

ELECTRICAL POWER SYSTEMS

ELECTRICAL POWER SYSTEMS Scope The various Codes applicable to the University's electrical power system are mainly based upon a model of a single utility service, connected to a single premise. The University s electrical system,

More information

Picture Report for Maersk Jabal

Picture Report for Maersk Jabal Picture Report for Maersk Jabal Vessel Name: Maersk Jabal Customer: Maersk line Ship Mgnt. Location: Keppel shipyard & Anchorage Date: 26 Mar 2016 to 06 April 2016 Jobs Description: To check and service

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only

More information

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: ELT 118 (2005-1) Identifier is the postsecondary course prefix followed by Plan-of-Instruction

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

Spectron LSN (Life Safety Network) Suggested Specifications

Spectron LSN (Life Safety Network) Suggested Specifications 1. General 1.1 Scope A Dual-Lite Spectron LSN (Life Safety Network) Series Inverter System shall be furnished to provide a reliable source of power, and shall operate during a utility line deficiency without

More information

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification

More information

Mobile home became 50 Non-Work

Mobile home became 50 Non-Work 07/10/2017 (died on the 19th Oct) Restaurant Male (56) Work Cleaning in Restaurant. Accessible part became live. 230 V 1st March 2016 Outdoor Farm Male 50 (32) Work Tree-Felling- Wet rope touched OH Line

More information

Fuji CAC Joint Stock Company

Fuji CAC Joint Stock Company CONTACT US Hanoi Fuji Electric Vietnam Business Office Ho Chi Minh City Headquarters Fuji Electric Corporation in South East Asia Singapore Fuji Electric Asia Pacific Thailand Fuji Electric (Thailand) Indonesia

More information