IR33 Universal Series IR33 Universal controllers Applications guide
|
|
- George Owens
- 6 years ago
- Views:
Transcription
1 IR33 Universal Series IR33 Universal controllers Applications guide Integrated Control Solutions for Energy Savings
2 2
3 Selection matrix 5 Replacement table 6 Programming instructions, parameters and alarm table 7 Standard temperature applications 13 IR33V7 1 Cool IR33V7 Alarm control (low temperature or high temperature) IR33W7 1 Heat / 1 Cool IR33W7 1 Heat / 1 Cool (heat pump) IR33Z7 1 Heat / 1 Cool with alarms IR33Z7 2 Heat / 2 Cool DN33Z7 2 Heat / 2 Cool (heat pump) IR33Z7 4 Cool IR33Z7 4 Heat page Special temperature applications 23 IR33W7 2 Cool circuits IR33E7H 2 Heat / Modulating Cool DN33E7H 2 Heat / Modulating Cool IR33E7H Modulating 1 Heat / 1 Cool with pump call Standard humidity applications 28 IR33V9 1 Humidification IR33V9 1 De humidification IR33W9 1 Humidification / 1 De humidification DN33W9 1 Humidification / 1 De humidification IR33V9 1 Stage Direct Acting Pressure IR33Z9 4 Stages Direct Acting Pressure DN33Z9 4 Stages Direct Acting Pressure IR33Z9 4 Stages Reverse Acting Pressure Index Standard pressure applications 33 Combined applications 37 DN33W9 1 Cool / 1 Humidification Accessories for IR33/DN33 Universal 39 3
4 4
5 Selection Matrix matrix Carel IR33 Universal Series Part Number Guide IR DN 33 V W Z D A B E Panel Mount Din Rail Mount One relay output Two relay output Four relay output One solid state output Four solid state output One relay + one 0-10V output Two relay + two 0-10V output 7 Temperature inputs 9 Universal inputs H L M Vac p. supply Vac/12-30 Vdc p. supply 24 Vac/dc p. supply R B IR, buzzer IR, buzzer, Real Time Clock 2 0 5
6 Replacement tables Replacement IR32 to IR33 Panel mount Type Old Code New Code 1 relay IR32V*L000 (12-24 Vac/dc) IR33V*LR20 (12-24 Vac/dc) 2 relay IR32W*0000 (12-24 Vac/dc) IR33W*LR20 (12-24 Vac/dc) 4 relay IR32Z*0000 (12-24 Vac/dc) IR33Z*LR20 (12-24 Vac/dc) 1 SSR IR32D*L000 (12-24 Vac/dc) IR33D*LR20 (12-24 Vac/dc) 4 SSR IR32A*0000 (12-24 Vac/dc) IR33A*LR20 (12-24 Vac/dc) 1 relay + 1 x 0-10V 2 relay + 2 x 0-10V IR32A*L x CONVONOFF0 + 1 x CONVO/10A0 IR32A* x CONVONOFF0 + 2 x CONVO/10A0 IR33B*H*20 (230 Vac) IR33E*H*20 (230 Vac) Replacement IRDR to DN33 Din rail mount Type Old Code New Code 1 relay IRDRV*0000 ( Vac) 2 relay IRDRW*0000 ( Vac) DN33V**R20 (12-24 Vac/dc) DN33V*HR20 (230 Vac) DN33W*LR20 (12-24 Vac/dc) DN33W*HR20 (230 Vac) 4 relay IRDRZ*0000 (12-24 Vac/dc) DN33Z*LR20 (12-24 Vac/dc) 4 SSR IRDRA*0000 (12-24 Vac/dc) DN33A*LR20 (12-24 Vac/dc) 1 relay + 1 x 0-10V 2 relay + 2 x 0-10V IRDRA* x CONVONOFF0 + 1 x CONVO/10A0 IRDRA* x CONVONOFF0 + 2 x CONVO/10A0 DN33B*H*20 (230 Vac) DN33E*H*20 (230 Vac) Note that in the new IR33 / DN33 range, every model is available with power supply Vac/dc (or 24Vac/dc) OR 240 Vac and optional Real Time Clock. Please contact us for more details. 6
7 Programming instructions, parameters and alarm table Programming instructions p. 8 Parameter list p. 9 Alarm table p. 11 7
8 8
9 9
10 10
11 11
12 12
13 Standard temperature applications IR33V7 1 Cool p. 14 IR33V7 Alarm control (low temp or high temp) p. 15 IR33W7 1 Heat / 1 Cool p. 16 IR33W7 1 Heat / 1 Cool (heat pump) p. 17 IR33Z 1 Heat / 1 Cool with alarms p. 18 IR33Z7 2 Heat / 2 Cool p. 19 DN33Z7 2 Heat / 2 Cool (heat pump) p. 20 IR33Z7 4 Cool p. 21 IR33Z7 4 Heat p
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 Special temperature applications IR33W7 2 Cool circuits p. 24 IR33E7H 2 Heat / Modulating Cool p. 25 DN33E7H 2 Heat / Modulating Cool p. 26 IR33E7H Modulating 1 Heat / 1 Cool with pump call p
24 24
25 25
26 26
27 27
28 Standard humidity applications IR33V9 1 Humidification p. 29 IR33V9 1 Dehumidification p. 30 IR33W9 1 Humidification / 1 De humidification p. 31 DN33W9 1 Humidification / 1 De humidification p
29 29
30 30
31 31
32 32
33 Standard pressure applications IR33Z9 4 Stages Direct Acting Pressure p. 34 IR33Z9 4 stages Reverse Acting Pressure p. 35 DN33Z9 4 Stages Direct Acting Pressure p
34 34
35 35
36 36
37 Combined applications DN33W9 1 Cool / 1 Humidification p
38 38
39 Accessories NTC probes NTC***HP00 : NTC probe -50 to +50 C plastic IP67 NTC***WP00: NTC probe -50 to +90 C stainless steel IP68 NTC***HT00: NTC probe 0 to +150 C plastic IP55 *** lengths available: 008 = 0.8m, 015 = 1.5m, 030 = 3m, 060 = 6m, 120 = 12m AXX: Brass pocket 8*60mm ¼ Gas for NTC probes AXX: Stainless steel pocket 8*60mm ¼ Gas for NTC probes. Other probes PTC : Bulb sensor (not waterproof), 1.5m, -50 to +130 C. SPKT00***0: Pressure probes. SPKC00*310: Cables for pressure probes. DP*C***000: Combined humidity and temperature probes. Other accessories Supervisory IRTRUES000: Remote control for IR33 and DN33 series universal. IROPZKEY00: Programming key for IR33 (batteries). IROPZKEYA0: Programming key for IR33 (230V). IROPZ48500: Serial card RS485 for IR33. IROPZSER30: Serial card RS485 for DN33. PP2STGSXE0: PlantVisorPRO2 Box with floating suction, parameter control and energy modules. PP2STGSTE0: PlantVisorPRO2 Touch with floating suction, parameter control and energy modules. PlantVisorPRO is a monitoring and telemaintenance system designed for medium to large size installations. Its features are: centralisation of the information from the field devices, monitoring of variables, management of alarms (through fax, SMS, s or relay), display of detailed and complete graphs, and a lot of other functions settable according to your installation. PWPROM0000: PlantWatchPRO with internal PSTN modem. MODEMGSM: GSM modem for PlantWatchPRO (for SMS sending). PlantWatchPRO is a PC-free logging and alarm solution ideal for small medium size installations. It features a large colour touch screen, can record variables and manage alarms. Note: The pre-configuration of PlantWatchPRO and PlantVisorPRO is available. Please contact us for more information. For the connection of the RS485 network, we recommend the use of the Belden 8760 cable (1 pair, 18AWG screened cable with drain wire). 39
40 IR33univ_AG rev1.4 29/09/2011 CAREL Australia Pty Ltd A.C.N Head Office Sydney Melbourne Office Brisbane Office 40 PO Box 6809, Silverwater Business Ctr., NSW 1811 Ph: Fax: PO Box 558, Mt. Waverley, VIC 3149 Ph: Fax: Suite 28, Bldg 6, 2404 Logan Rd, Eight Mile Plains, QLD 4113 Ph: Fax:
Temperature & Humidity Control Systems for the Wine Industry
Temperature & Humidity Control Systems for the Wine Industry Making wine is a process based on tradition. The taste, bouquet and other characteristics of the wine, which are highly appreciated by the consumer,
More informationTemperature - Humidity - Pressure
TEMPERATURE-HUMIDITY-PRESSURE INDICATORS XA100C Configurable digital indicators for temperature, humidity or pressure C: 32x74mm DC- TBXABDA100 XA100C -0C0PU PTC NTC inputs 12V DC- TBXABCA100 XA100C -0C0TU
More informationMTRA-FSP Level Control Relay. Installation & Operation Manual
MTRA-FSP Level Control Relay Installation & Operation Manual This Manual is the support documentation for the installation, commissioning and operation of the MTRA-FSP Level Control Relay. Document Revision
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationCentaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE
Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment
More informationEMERGENCY LIGHTING SYSTEM
EMERGENCY LIGHTING SYSTEM 1300 INCITE www.incitefire.com.au PRODUCT CATALOGUE EXIT-EMERGENCY LIGHTING AN EXTRA LOW VOLTAGE EXIT & EMERGENCY LIGHTING SYSTEM FIREscape is a revolutionary emergency lighting
More informationHigh pressure water atomizing humidifier 30.3 (770) Energy saving! 32 (810) 1.5 (40) max 1 (24) 14 (355) 1 (22,6) 1.5 (38) .
High pressure water atomizing humidifier Energy saving! 32 (810) 30.3 (770) 1.5 (38) 14 (355) 1 (22,6) max 1 (24) 1.5 (40) 32 (810).12 (3) Energy Saving: with an electric power consumption of just 1.8
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.
ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration
More informationComplete packages with Software and Controller
Thermoguard Basic Complete packages with Software and Controller Thermoguard Basic packages contain the software, one sensorcontroller and one sensor. The functional scope of the Thermoguard Basic software
More informationCATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION
CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN
More informationCONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document
CONTROLS MANUAL CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF Original document Contents 1. General description....5 2. Set-up... 6 2.1. micropc control board... 6 2.2. TCO user
More informationDEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications
with RS485 XH50P XH55P Dixell extends its own range of temperature/humidity sensors with new XH50P and XH55P models equipped with RS485 ModBUS-RTU compatible and capable to evaluate the current dew point
More informationHRX Technical Manual. Version 1.2
HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire
More informationBoztek Solutions` PLAYSTATE
Boztek Solutions` PLAYSTATE REMOTE MONITORING & CONTROL SYSTEM FOR PLAYING FIELDS & OPEN SPACE Contact Details: Boztek Solutions Pty Ltd PO Box 272, Windsor, NSW 2756 Unit 12/124 Ham Street, South Windsor,
More informationAFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3
OPERATORS MANUAL AFP-300/400 INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02) 9899-4155
More informationSTROBE / SOUNDER INTERFACE
STROBE / SOUNDER INTERFACE INSTALLATION & CONFIGURATION MANUAL 21/10/2010 Rev: 2.00 DOC-01-002 ECN10-183 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If
More informationETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions
ETN24-P/PD-FC-SUPER2 Owner's Manual - Installation and Operating Instructions Rev. 1 04.08 itav-tec Ltd (Contel group) Tel: +972-3-9626462 Fax: +972-3-9626620 www.meitavtec.com - support@meitavtec.com
More informationRefrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301
Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control
More informationir33 platform ir33 ir33 power ir33 DIN powercompact powercompact small mastercella
ir33 platform ir33 ir33 power ir33 DIN powercompact powercompact small mastercella User manual User manual IMPORTANT WARNINGS CAREL bases the development of its products on decades of experience in HVAC,
More informationConnectivity, a guide for supervision
Connectivity, a guide for supervision Plug&play, open and project-based HVAC/R supervision solutions CAREL, leader in control solutions for HVAC/R, offers the market a range of solutions based on its profound
More informationData Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)
Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display
More informationHRX3000. Technical Manual
HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem
More informationSL2210 SAMSUNG GU10 LED Lamp RECESSED LED DOWNLIGHTS
SL2210 SAMSUNG GU10 LED Lamp RECESSED LED DOWNLIGHTS SL2210 SAMSUNG GU10 LED LAMP The Superlight SL2210 is a high quality 10W LED GU10 downlight lamp suitable for new and existing projects. The universal
More informationFIRElux Emergency Lighting
ABC a FIRElux Emergency Lighting Safety In All Enviroments FIRElux is a completely new emergency lighting system. The rapid development of LED technology has made it possible to implement emergency lighting
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationFratech Multipath-IP
Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document
More informationDehumidification units CONTROL BROCHURE NA A Electronic control. CIATpool
Dehumidification units CONTROL BROCHURE NA 14.66 A 11-2014 Electronic control Contents 1. General description...5 1.1. Comunications...6 1.2. Supervision solutions...6 2. Set-up...7 2.1. μpc MEDIUM control
More informationFSD-6/ 09 FOODSERVICE DEALER CATALOG
FSD-6/ 09 FOODSERVICE DEALER CATALOG Since 1882 the Weiss Instruments name has been synonymous with Quality, Reliability and Innovation with HVAC and Food Service OEMs. Weiss Instruments is the name behind
More informationheatersteam unprecedented precision and reliability
heatersteam unprecedented precision and reliability Electric heater humidification Reliable and precise technology for high-tech applications. Steam production is modulated with the highest precision,
More informationIMPORTANT WARNINGS. Before installing or handling the appliance please carefully read and follow the instructions described in this manual.
User manual We want to save you time and money! We can assure you that the thorough reading of this manual will guarantee correct installation and safe use of the product described. IMPORTANT WARNINGS
More informationSecurity designed for your lifestyle
Security designed for your lifestyle The Paradox Insight : The Big Picture A single CAT5 or higher cable can be used to wire a single HD77 camera. Camera Detector Module HD 720p camera Quad PIR with auto
More informationBC3250. Blowdown Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMonitoring and Controls
Monitoring and Controls Thermometers 24DT 20DT 24DT-S 24DT-L Also available in Blue Display The New Generation LED Thermometers include our exclusive Direct Power Feature eliminating the need for an external
More informationEXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability
EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability Technical Bulletin EXD-SH1/2 are stand-alone universal superheat and or temperature controllers for air conditioning units or refrigeration
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 is an electronic temperature controller which can be loaded with selected applications by means of an ECL Card. The ECL
More informationCAREL heatersteam Electric Element Steam Humidifiers
Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]
More informationUser manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier
DATALogic2 DAT AIR CONTROLLER Manual 201716A02 Issue 09.00 Replaces --.-- User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier 1370 Program code: FLAIRMCDZC
More informationEXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability
EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability Technical Bulletin EXD-SH1/2 are stand-alone universal superheat and or temperature controllers for air conditioning units or refrigeration
More informationNEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationUpgrade of PSTN network Alarm System
Upgrade of PSTN network Alarm System Introduction Network alarm system is a variety of transmission channels to transmit protection areas information to security service center quickly and accurately,
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page
More informationEviKontroll Silo. Monitor Your Grain Anytime, Anywhere
C Grain temperature monitoring system Monitoring the temperature inside grain silos is the most important measure to assure the storage quality. EviKontroll Silo fully automatic temperature monitoring
More informationSL2832 LED Wedge Wall Light 7W ARCHITECTURAL LED WALL LIGHTS
SL2832 LED Wedge Wall Light 7W ARCHITECTURAL LED WALL LIGHTS SL2832 LED WEDGE WALL LIGHT 7W Superlight LED wedge wall light fixture are suitable for high end architectural projects. They contemporary design
More informationThe full range of Evaporator Controls from ADAP-KOOL
MAKING MODERN LIVING POSSIBLE The full range of Evaporator Controls from ADAP-KOOL ADAP-KOOL case controllers offer highly efficient adaptive routines for each cabinet and cold room installation guaranteeing
More informationIndex. 1. General description of the application Types of units controlled Types of regulation Condensation...
LCS pco ADVANCED MICROPROCESSOR USER MANUAL GB Index 1. General description of the application... 4 1.1. Types of units controlled...4 1.2. Types of regulation...4 1.3. Condensation...4 1.4. Safety devices
More informationUSER MANUAL. CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF
USER MANUAL CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF Translation of the original document 80154, 01.2016 Contents 1. General description....3 1.1. Comunications... 4 1.2. Supervision solutions...
More informationTemperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI
HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module
More informationExtension Module. Fig.1
Extension Module Type FD 4201 05/12.17 General Description Module FD 4201 is optional for the fire control panel FS4000. Expands the functionality of the fire control panel, as follow: - Connection of
More information7 USE THE COMMANDS INTERNET VOICE MESSAGES RECORD VOICE MESSAGE DURATION OF VOICE MESSAGES 64
MANUAL FOR PROFORT GSM DEVICES 1 MANUAL FOR PROFORT GSM DEVICES 2 1.1 SPECIFICATIONS 2 1.2 FUNCTIONS 4 1.3 DESCRIPTION 6 1.4 SYSTEM ILLUSTRATION 7 2 MOUNTING 8 2.1 PREPARE THE UNIT 8 2.2 ELECTRIC MOUNTING
More informationIEI NETWORK INTERFACE MODEL TS2040
IEI NETWORK INTERFACE MODEL TS2040 INSTALLATION GUIDE Revised! see Protective Earthing Addendum NOTE: This equipment must only be installed and serviced by professional qualified personnel. O O + - D+
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationPanels 65 + Non-Weatherproof Weatherproof MurphyLink. Australia. Years. of Macquarrie Excellence
Panels Non-Weatherproof Weatherproof MurphyLink Designed & Built in Australia for Australian conditions of Macquarrie Non-Weatherproof Our range of non-weatherproof panels provide high-quality and reliable
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE
More informationTOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design
TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationOrange Solar Pump HD50
Orange Solar Pump HD5 36 volt DC brushless step motor Loss of prime protection - Automatic tank filling How the pump works The HD5 centrifugal solar pump is made of stainless steel with a plastic impeller.
More informationKT-100 Door Controller
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
More informationMiniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)
PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics
More informationIn installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK
Access Control CENTRALISED CAC The CAC (centralised access control ) allows complex installations with several accesses and additional functions. It also makes it possible to integrate other services:
More informationStandard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve
Application program for pco¹ pco² pco 3 Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve 1.1 09 / 11 / 2006 version of manual Program code: FLSTDmMSBE We wish to save you
More informationOperating Instructions. For. Alarm Control Module. Model SSR 500
SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions
More informationPERMACONN PM1030 Includes DI300. Installation Manual
PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides
More informationPOCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS
POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT
More informationModular Standard HP Chiller 1/4 screw compressor with Carel driver
Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?
More informationSL3164 Neptune Inground Square LED Uplight EXTERIOR / LANDSCAPE LIGHTING
SL3164 Neptune Inground Square LED Uplight EXTERIOR / LANDSCAPE LIGHTING SL3164 NEPTUNE INGROUND LED UPLIGHT SQUARE Superlight LED Neptune 12W fittings are high quality inground LED uplights ideal for
More information1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0
1 INCA CONTROL PTY LTD Phone: (02) 96753815 UNIT 14/62 OWEN ST Fax: (02) 96751381 GLENDENNING NSW 2761 A.B.N 54 131 353 636 Design & Manufacture of: Custom-built switchboards Electronic control equipment
More informationECL Comfort 300 / V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL
More informationYOUR PARTNER IN FIRE & GAS DETECTION
YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com
More informationAnalog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation
Gas Detection Control Panel Analog and digital controller 4 or 8 lines / 6 to detectors max Highly versatile controller Cost savings on wiring installation Certifications The The Fixed Fixed Gas Gas Detection
More informationTEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs
TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR
More informationE74 E76 E78 HOT FOOD DISPLAYS
E74 E76 E78 HOT FOOD DISPLAYS -1- MANUFACTURED BY Moffat Limited PO Box 10001 Christchurch New Zealand Ph: (03) 389 1007 Fax: (03) 389 1276 WORLD-WIDE BRANCHES UNITED KINGDOM Blue Seal Units 6-7, Mount
More informationTTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS
TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must
More informationTMEF Series. SKOPE Vertical Freezer. User Manual
TMEF Series SKOPE Vertical Freezer MAN10132 Rev. 1.0 Oct. 2010 TMEF Series SKOPE Vertical Freezer Type: (CAREL ir32 Controller) MAN10132 Rev. 1.0 Oct. 2010 2010 SKOPE Industries Limited. All rights reserved.
More informationMaglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY
Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY Main features Event recording up to 32 Gb removable microsd card (only
More informationCARD ACCESS CONTROL SYSTEM
SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where
More informationHot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological
Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution
More informationOPERATION / INSTALLATION
OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)
More informationHTA ACCREDITATIONS. NADCAP (Heat Treating) 2 AS 9100C 5-6 ISO NADCAP (Heat Treating) 3 AS 9100C 5-6 ISO NADCAP (Heat Treating) 4
HTA ACCREDITATIONS page HTA AEROSPACE & DEFENSE / HTA BRISBANE NADCAP (Heat Treating) 2 AS 9100C 5-6 ISO 9001 7-8 HTA AEROSPACE & DEFENSE / HTA MELBOURNE NADCAP (Heat Treating) 3 AS 9100C 5-6 HTA SYDNEY
More informationNote that the cable must be handled with great care to avoid damages to the cable during transport etc.
Monitoring systems 7:101 Monitoring systems The purpose of a moisture monitoring is to detect and locate moisture in the pipe insulation. This provides a cost effective and easy to use tool to monitor
More informationControl THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES
Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES CONTROL CONTROLLO THV THR THERMOSTATS Compact Thermostat for DI 35 mm. rail mounting. Based on bimetallic junction, provides high capacity
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationTechnical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity
Modular Air Cooled Condensers Technical Data ACN Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 68 kw 155 kw MARCH 2010 ACN SERIES MODULAR AIR COOLED CONDENSERS General The ACN
More informationFireNET Plus Wiring Instructions
FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to
More informationMANUAL FOR PROFORT GSM/LAN DEVICES Ver MANUAL FOR PROFORT GSM/LAN DEVICES 3
MANUAL FOR PROFORT GSM/LAN DEVICES 1 MANUAL FOR PROFORT GSM/LAN DEVICES 3 1.1 SPECIFICATIONS 3 1.2 FUNCTIONS 5 1.3 DESCRIPTION 8 1.4 SYSTEM ILLUSTRATION 10 2 MOUNTING 11 2.1 PREPARE THE UNIT 11 2.2 ELECTRIC
More informationECO601 OPERATING INSTRUCTIONS ME04
RAK 72.2 9.11.2010 1 2 3 4 5 6 7 8 9 0 # ECO601 OPERATING INSTRUCTIONS ME04 PRESENTATION The ECO601 is intended for the simple control and surveillance of premises. This device can be controlled locally
More information920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).
Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based, multipoint heat-trace controller. The 920 provides control and monitoring of two independent electrical heat-tracing
More informationMonitoring Solutions
GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5
More informationChallenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )
Revised! see Protective Earthing Addendum Installation Guide J2 O O J1 4 IN 3 RELAY OUTPUTS EXPANSION 2 J3 1 O O Relays: A 4 way Relay Module provides four 1 Amp single pole Relays with connection terminals
More informationMonitoring solutions
Monitoring solutions Grade A1. Latest monitoring technology. Providing 24/7 coverage 365 days a year, our highly skilled monitoring teams offer vigilant protection. Valued and strong relationships With
More informationAS DIGITAL FIRE PUMP CONTROLLER
AS 2941-2013 DIGITAL FIRE PUMP CONTROLLER COMPLIANT WITH AS2941-2013 CLAUSES 9.4.1 9.4.22 OPERATION INSTRUCTIONS New South Wales Unit 2/1040 Canley Vale Road Wetherill Park NSW 2164 Ph: +61 2 9757 5800
More informationINSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationI/O module: CAREL retrofit controller. User Manual
I/O module: CAREL retrofit controller User Manual We wish to save you time and money! We can assure you that the thorough reading of this manual will guarantee correct installation and safe use of the
More informationDIY Smart Home & Energy Save
2011 Catalog Going green DIY Smart Home & Energy Save www.ekonsense.com Simply Smart E K O N Manufacturing Inc. Global Excellence in Affordable Control Systems EKON Manufacturing Inc. is one of the world's
More informationTHERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16
TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationAdvanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module
Clavex Plus Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module PC Software Controller with Graphic Display Printer Module Features
More informationController Specification Sheet
Controller Specification Sheet MC9550ABXXBX Proportional Inhibitor Dosing, Dual Conductivity Bleed Control, Dual Point ph Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol
More information