TAITA TAVETA UNIVERSITY P.O.BOX , VOI, KENYA Tel: TENDER NO: TTU/T/01A/
|
|
- Jonas Hamilton
- 5 years ago
- Views:
Transcription
1 TAITA TAVETA UNIVERSITY P.O.BOX , VOI, KENYA Tel: TENDER NO: TTU/T/01A/ CONSTRUCTION OF PROPOSED ADMINISTRATION BLOCK- TAITA TAVETA UNIVERSITY MAIN CAMPUS (ELECTRICAL INSTALLATION SUBCONTRACT WORKS) ADDENDUM NO. 1 CLOSING DATE: 31 ST AUGUST, 2017: AT 11.00AM
2 BILL OF QUANTITIES ITEM DESCRIPTION QTY UNIT RATE KSH Supply, install and commission the following:- 1 Lighting points wired in 3x1.5 sq.mm SC PVC Copper cables drawn in concealed 20mm DIA HG PVC conduits including all accessories but without the lighting fittings and switches for; a) One way switching 470 No. b) Two way switching 178 No. 2 10A white moulded lighting switches as MK or approved equivalent as follows:- a) One gang one way 77 No. b) Two gang one way 45 No. c) One gang two way 36 No. d) One gang intermediate 12 No. 3 Lighting fittings complete with appropriate lamps as follows:- a) 1200mm, 1x18W LED fitting. To be OSRAM, THORN or approved equivalent 215 No. b) 1200mm, 1x18W LED fitting complete with antiglare louvre. To be OSRAM, THORN or approved equivalent 86 No. c) ditto but TWIN 258 No. d) 1200mm, 1x14W LED fitting complete with waterproof prismatic diffuser. To be OSRAM, THORN or approved equal. 67 No. e) 1200mm, 1x14W LED fitting complete with dampproof prismatic diffuser. To be OSRAM, THORN or approved equal. f) 18W LED bulk head fitting. To be OSRAM, THORN or approved equivalent. 1 g) Wall-bracket fitting complete with 18W LED lamp as OSRAM, THORN or approved equal. h) 14W LED Panel Light (Round) as OSRAM, YellowStar or approved equal. E1
3 4 1.5 sq.mm 2 core PVC/SWA/PVC Copper buried 1 foot 160 M underground for the 4No. spot lights. b) 100W LED spot light as OSRAM or approved equivalent. 5 Emergency lighting points wired in 3x1.5 sq.mm SC PVC Copper cables drawn in concealed 20mm DIA HG PVC conduits, including all accessories but without the lighting fittings. 112 No. b) LED non-maintaned Emergency lights as CLIPSAL, YellowStar or approved equivalent 112 No. 6 Socket outlet points wired in 3x2.5 sq.mm SC PVC Copper cables concealed in Steel Trunking 566 No. b) 13A metallic socket outlet plate with a neon indicators as MK, CRABTREE or approved equivalent TWIN 566 No. 7 Power points wired in 3x2.5 sq.mm SC PVC Cu cables concealed in 20mm DIA PVC HG conduits for hand driers. b) 20A, Switched & fused Double Pole spur outlet with a neon indicator as CRABTREE, CLIPSAL or approved equavalent. 40 No. 40 No. c) 1.5KW hand drier as LORENZETTI or approved equal. 8 Power points wired in 3x4.0 sq.mm SC PVC Copper cables concealed in 25mm DIA PVC HG conduits for cooker unit. b) 45A cooker control unit complete with pilot lamp and 13A auxialliary switched socket outlet as CRABTREE or approved equivalent. 40 No. 16 No. 16 No. c) Cooker connection unit as CRABTREE or approved equivalent. 9 Ceiling fan points wired in 3x1.5 sq.mm SC PVC Copper cables drawn in concealed 20mm DIA HG PVC conduits including all accessories but without the ceiling fan and its regulator. a) Standard ceiling fan complete with control switch. To be ORIENT, Crompton Greaves or approved equal. 16 No. 32 No. 32 No. E/2
4 10 Power points wired in 3x4.0 sq.mm SC PVC Copper 50 No. cables concealed in Trunking for air conditioning units. b) 20A metallic socket outlet plate with a neon indicators as MK, CRABTREE or approved equivalent TWIN 50 No A, Four Pole Busbars Free-standing Distribution Board complete with 3No. digital voltmeters and phase indicators. To be TELEMECANIQUE, SCHNEIDER or approved equivalent. 1 No. MCCBs for item 11 above a) 200A TP (Incomer) 1 No. b) 80A TP (Outgoer) 3 No. c) 100A TP (Outgoer) A metal clad switchfuse (main switch) complete with phase indicators. To be MEM or approved equal. 1 No A metal clad switchfuse as MEM or approved equal. 2 No A, 8-Way, TP+N+E Distribution Board complete with 100A integral isolator. To be Hager or approved equivalent 6 No. b) ditto but 4-Way 1 No. MCBs for item 14a above: a) 10A SP 15 No. b) 30A SP 25 No. c) 40A SP 15 No. MCBs for item 14b above: a) 32A TP 15 Submains wired in 25 sq.mm 4 core PVC/SWA/PVC Copper cable for the 7No. Distribution Boards. 120 M mm x 50mm spray painted steel trunking flush mounted on walls 2100 M 17 50mm HG PVC conduit for bypassing the steel trunking 700 M sq.mm 4 core PVC/SWA/PVC Copper supply cable) 70 M E/3
5 19 Pure copper multispiked lightning arrester as per MOPW standards. b) 3 x 35mm pure copper tape 200 M 20 Earthing the main switch board and the lightning arresters comprising the following; (i) 1500mmx15mm diameter copper electrode complete 5 No. with clamp (ii) 10.0 sq.mm yellow/green PVC single core cable 30 M. (iii) Precast inspection pit complete with cover 5 No. 21 Conduiting work for CCTV cameras done using 20mm diameter PVC HG conduits complete with draw wire. 700 M 22 Supply and install Addressable intelligent 6-loop fire alarm panel, self-maintained complete with indicator lamps, test and reset button, internal buzzer, internal charger and batteries and all other accessories Menvier DF DF6000/1 1 No. 23 Fire alarm break glass and bell points wired in 2 core screened fire resistant LS OH cables drawn in concealed 25mm diameter PVC conduits complete with all accessories 18 No. 24 Supply and install Addressable fire alarm break glass unit complete with all accessories flush mounted as Menvier Cat.No. MBG 814F or approved equivalent 18 No. 25 Supply and install Addressable fire alarm sounder bell complete with all accessories as Menvier Cat. No MAS 5850LPS or approved equivalent 2 No. 26 Fire alarm smoke detector points wired in 2 core screened fire resistant LSOH cables drawn in concealed 25mm diameter PVC conduits complete with all accessories 27 Supply and install analogue addressable photo thermal smoke detector complete with all accessories as Menvier part No.MAP 820 or approved equivalent 28 Allow for programming, testing and commisioning of the above fire alarm system 61 No. 61 No. 1 lot E/4
6 ITEM DESCRIPTION QTY UNIT RATE KSH PROPOSED MAIN SWITCHBOARD AT GENERATOR HOUSE Supply, install, test and commission the following:- 1.1 Free standing 18gauge, 800A, 415V four pole Busbar switch board complete with 800A 4No. Pure copper Busbars and with space for KP&Lco digital metering facilities, frequency, ammeter, voltmeter, power factor correcton,in-built change over chamber, shunt-trip coil for fireman switch, and all accessories except MCCBs 1 No. 1.2 Moulded case circuit breakers, as LOADSTAR or approved equivalent complete with all accessories a) 800A TP main isolator MCCB 2 No b) 200A TP for outgoing ccts 2 No c) 100A TP for outgoing ccts 4 No d) 80A TP for outgoing ccts 4 No e) 60A TP for outgoing ccts 4 No f) Provision for outgoing spares 2 No. 1.3 Earthing as MOW standard using an Earth Mat and 25 x 3mm pure copper tape 1 lot (b) Precast inspection earth pit complete with cover 1 No E/5
7 1 95KVAr capacitor Bank completely wired with the following items complete with all accessories. 1 No a) 230A TP & N MCCB main switch 1 No b) Capacitors complete with discharge resistors 1 lot c) Contactors complete with limiting resistors 1 lot d) HRC TP fuse bases with fuses 1 lot e) Power factor regulator, fully programmable complete with control fuses. 1 lot 2 Installation and connection of capacitor 1 lot banks to New main switchboard using: a)95 sq mm 4 core PVC/SWA/PVC copper cable complete with cable glands 10 m b) 2.5sq mm PVC/SWA/PVC copper cable control complete with cable glands 10 m c) 800/5A current Transformer 1 No 3 Earthing and all accessories 1 lot 4 Any other item for successful installation of the capacitator Banks 1 lot E/6
8 1 Schedule E/1 2 Schedule E/2 3 Schedule E/3 4 Schedule E/4 5 Schedule E/5 6 Schedule E/6 6 Contingencies 1,500,000 TOTAL OF ELECTRICAL WORKS CARRIED TO GRAND SUMMARY
Proposed Development at Likoni Road, Nairobi for NTSA - Electrical Installations Bills of Quantities. DESCRIPTION QTY UNIT RATE AMOUNT KSh. 28 No.
BILL 1 GROUND FLOOR Supply, Deliver, Install, Set to Work and Commission the Following: 1.01 Lighting point completely wired in 3x1.5mm² single core PVC insulated copper cables drawn in 20mm diameter HG
More informationSCHEDULE OF RATES SHEET PRELIMINARIES
Page : 1 PRELIMINARIES 1 CONTAINER BUDGET ALLOWANCE 1,100.00 1,100.00 1 SUPERVISION 3,900.00 3,900.00 1 ACCOMMODATION 5,390.00 5,390.00 1 TRAVEL ALLOWANCE 7,800.00 7,800.00 Sub- 18,190.00 18,190.00 Page
More information1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT
A MAIN PANEL/DB 1 Supply and Installation of main LT panel, floor mounted, front operated dead back, totally enclosed vermin proof, indoor, non drawout, cubicle type power dist. panel fabricated out of
More informationSBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.
SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD. (A Wholly Owned Subsidiary of SBI) CIRCLE OFFICE: 4TH FLOOR, SBI LOCAL HEAD OFFICE III/1-PANDIT J N MARG, KHARAVELA NAGAR BHUBANESWAR, ODISHA-751001 Part-II PRICE
More informationDC POWER DISTRIBUTION BOARD
DC POWER DISTRIBUTION BOARD February 2016 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091.
More informationSCHEDULE OF QUANTIY S.N. DESCRIPTION QTY UNIT RATE TOTAL
SCHEDULE OF QUANTIY S.N. DESCRIPTION QTY UNIT RATE TOTAL SECTION - A ( PANELS & D.B's) 1 Supply, Installation, Testing & Commissioning of 125 Amps TPN SFU with 100 Amps HRC fuses in the Meter room. QRO
More informationTable-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion
Table-1: Clarifications and modification in tender s based on Pre-bid meeting discussion Sr. Ref Page. 1 4 Clause Site Preparation and Partitions walls 2 11 SLD 3 18 Batteries 4 18 Batteries 5 32 to 34
More informationGOLDFIELDS PRIMARY SCHOOL. TENDER SPECIFICATION For ELECTRICAL SERVICES MECHANICAL ENGINEER:
GOLDFIELDS PRIMARY SCHOOL TENDER SPECIFICATION For ELECTRICAL SERVICES PROJECT MANAGER: School Support Dunedin ARCHITECTURAL DESIGNER: Katipo Design ELECTRICAL ENGINEER: Pedersen Read Dunedin MECHANICAL
More informationELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET
EST 2066 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Two Hours INSTRUCTIONS
More informationElectronic 7 Installation Instructions
Electronic 7 Installation Instructions The Horstmann Electronic 7 is an advanced water heating control, which can be programmed to take advantage of cheap night-rate electricity, so that there is a tank
More informationOakdale Primary School Expansion Project Appendix C Elec Equipment Schedule
Oakdale Primary School Expansion Project Appendix C Elec Equipment Schedule HBS-SH-MEP-803 May 2017 For Peterborough City Council ver. author date checked comment P1 DH 19-05-17 TJC TENDER ISSUE 1 Ref
More informationGuide to: 17 th Edition Consumer Units
Guide to: 17 th Edition Consumer Units Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationElectrisaver User and Installation Instructions
Electrisaver User and Installation Instructions The Electrisaver push button boost timer can be used to control immersion elements and other electrical appliances up to 3kW or as an override/extension
More informationUser Information Sheet 008 : 2010
User Information Sheet 008 : 2010 Formerly UIS008, July 2009 ELECTRICAL INSTALLATIONS ASSOCIATED WITH BULK LPG INSTALLATIONS 1. Introduction This Information Sheet describes some of the principles and
More informationLAWSON FINAL DISTRIBUTION PRODUCTS RANGE
FINAL DISTRIBUTION PRODUCTS RANGE ISO 14001:2004 Certified ISO 9001:2008 Certified FUSES INDIA LTD Lawson Fuses India Ltd is a wholly owned subsidiary of Lawson Fuses Ltd,a long established UK company
More informationA. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.
SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:
More informationEmergency Assist Alarm Kit Single Zone
Emergency Assist Alarm Kit Single Zone Model: EASZKN Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.
More informationFIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module
FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required
More informationsoaring high. scoring high. Trading Co. LLC
soaring high. scoring high. Trading Co. LLC SWITCHING GEARS TO GREATER SUCCESS Skyway tells a tale of electric growth that began in 1992. Coming a long way in its core business of electrical panel boards
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationStudent Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.
SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 119/IWD/ED/644 SCHEDULE OF QUANTITY Name of work: Electrical work for: Part-A: Rewinding, overhauling and repairing of ceiling fan and exhaust fan installed
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationUSED ELECTIONS. 1. Lighting network
TECHNI CALREPORT USED ELECTIONS 1. Lighting network In the premises of the building will be installed cold light with type LED floodlighters. The lighting system is designed to be made with FROR conductor
More informationMINERVA MX. 800 Series Ancillary Equipment
An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree
More informationELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET
Candidate Code No. EIN 11 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS
More informationPrem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES
Prem1er EVACS16 VOICE ALARM CONTROL PANEL 4 16 ZONES Installation Manual Approved Document No: GLT.MAN-141 PAGE 1 INDEX INDEX... 2 Summary... 3 Safety information & use of this manual... 5 Installation
More informationUEE30811 Q-Tracker Work Tasks
UEE30811 Q-Tracker Work Tasks UEENEEC020B Participate in electrical work and competency development activities Q-Tracker requirements: 40 hours of practical training. 1. Comply with electrical industry/enterprise
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationREPUBLIC OF KENYA MINISTRY OF HEALTH BIDDING DOCUMENT VOL 3.1 GENERAL ELECTRICAL INSTALLATIONS (ALL RATES EXCLUSIVE OF TAXES)
REPUBLIC OF KENYA MINISTRY OF HEALTH EAST AFRICA S CENTERS OF EXCELLENCE FOR SKILLS AND TERTIARY EDUCATION IN BIOMEDICAL SCIENCES PROPOSED CONSTRUCTION OF EAST AFRICA S KIDNEY INSTITUTE COMPLEX AT KENYATTA
More informationEDS SUBSTATION ELECTRICAL SERVICES
Document Number: EDS 07-1119 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 07-1119 SUBSTATION ELECTRICAL SERVICES EPN, LPN, SPN This standard specifies the electrical services requirements including
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET
Candidate Code No. EAS 1081 For Board Use Only Result Date Int Result Date Int ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time
More informationPort of Portland Conveying Equipment Guidelines
Role: Consultant for the Port Design Guidelines Port of Portland Conveying Equipment Guidelines ELEVATOR, ESCALATOR, AND MOVING WALK DESIGN OVERVIEW The Division 14 specification sections include appropriate
More informationPNG POWER Ltd REQUEST FOR TENDER
PNG POWER Ltd REQUEST FOR TENDER FOR THE SUPPLY AND DELIVERY OF ONE (1) x 500 KW 415V CUMMINS DIESEL GENERATING SET COMPLETE WITH FREE STANDING CONTROL/SWITCHBOARD, FOR KEREMA DIESEL POWER STATION. Tender
More informationElectrical Equipment & Systems
ELECTRA has been associated with world renowned electrical equipment and systems manufacturers since 1965. Our international manufacturers and suppliers are known for their quality, creativity, unique
More informationES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int
ES8 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICAL WORKERS REGISTRATION BOARD ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 9 September 2006 QUESTION AND ANSWER BOOKLET
More information3500 CONVENTIONAL FIRE ALARM CONTROL PANEL
3500 CONVENTIONAL FIRE ALARM CONTROL PANEL INSTALLATION AND COMMISSIONING MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax:
More informationLC3000 Level Controller Installation and Maintenance Instructions
4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.
More information(Notices) EUROPEAN COMMISSION
14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework
More informationInstallation & Operating Instructions
Emergency Assist Alarm Models covered: EACP1 Single Zone Plastic Control Unit (with battery backup EACP1PR) EASSCP1 Single Zone Stainless Steel Control Unit (with battery backup EASSCP1PR) EARB1 Plastic
More informationMenvier Fire System MF9300
Menvier Fire System MF9300 Eight and sixteen zone control panels Installation and User Instructions and Systems Log IMPORTANT THIS MENVIER FIRE PANEL IS DESIGNED TO BE USED WITH POLARISED AND SUPPRESSED
More informationSCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL
SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm
More informationSita200plus. 200detectors. Single loop analogue addressable System
Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationSection 8 Electrical.
Design Guidelines Section 8 Electrical. www.canterbury.ac.nz/learningresources Standards in the Design Guidelines Suite Design Standard Guidelines Index: 01 General 02 Architecture 03 Audio Visual 04 Civil
More informationCedarbrook Sauna + Steam Family owned and operated since 1971
Cedarbrook Sauna + Steam Family owned and operated since 1971 We build cedar saunas, kits, sauna doors, accessories for commercial saunas & residential sauna rooms AND we have the expertise to fit you
More informationINITIAL ELECTRICAL ASSESSMENT REPORT (EAR)
INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Assessor: Karardi, Shibpur, Narsingdi Narsingdi Dhaka Bangladesh Emkay Enterprises The Alliance for Bangladesh Worker Safety Page 1/15 10 Apr 2016 Introduction
More informationAnnexure - 1. Detectors: Fire Alarm Control Panel :
Item 1. Supply Part This Specification includes Supply, Warranty, Installation, Testing and Commissioning and integration of the Fire Alarm System mainly consisting of the Fire Alarm Control Panel (FACP),
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationBrands & Products List
Brands & Products List S. No. Brand Name Range of Materials 1 DUCAB Single Core Cables, XLPE Insulated Cables, Rubber/Welding Cables & Fire Performance Cables 2 Abu Dhabi Cable Single Core Cables & XLPE
More informationELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011
Candidate Code No. ESAI 27 For Board Use Only Result Date Result Date Int ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011 QUESTION AND ANSWER BOOKLET Time Allowed: 3 Hours INSTRUCTIONS
More informationWelcome to Hager Presentation
Welcome to Hager Presentation Topics Intro to Hager Group Circuit Protection Enclosures Q&A IIEE Manila 4 th August 17 13.03.2009 2 Company presentation Who we are Hager Group is a leading provider of
More informationBS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE
BS-100 DYFI Protecting environment, life and property... P-BS100/DCE P-BS100/DCE/Doc/961023 2 Autronica Fire and Security AS Contents Please observe! This handbook contains installation instructions for
More informationLoadCentre KQ Distribution boards
> LoadCentre KQ Distribution boards 4 LoadCentre KQ - single phase A distribution boards - 125A Single phase A distribution boards - 125A Manufactured and tested to BS EN 61439-3 Maximum busbar 125A Voltage
More informationFEC400 Series. Installation Manual
FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationConsumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671
Consumer Units for Domestic Household (and other) Premises Amendment No. 3 BS 7671 ALL METAL CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES 17th Edition Wiring Regulations Incorporating Amendment
More informationFire detection and alarm system Installation instructions
Fire detection and alarm system Installation instructions Installation instructions Table of Contents Table of Contents ------------------2 Preface -----------------------3 Associated Documents 3 Conventions
More informationINITIAL ELECTRICAL ASSESSMENT REPORT (EAR)
INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Factory Address: 687, Al-Haj Nurl Amin Sowdagar Lane CDA, R/A, Road No 20, South Agrabad Chittagong Chittagong Bangladesh 03 Apr 2014 The Alliance for Bangladesh
More informationINSTALL AN ELECTRIC SHOWER
INSTALL AN ELECTRIC SHOWER The plumbing and wiring involved in installing an electric shower requires sound basic skills in both areas of expertise. Ensure that wiring and plumbing are properly installed.
More informationInstallation and User Instructions HS10U, HS15U.
Installation and User Instructions HS10U, HS15U. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation PACK CONTENTS
More informationSUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.
i 1 a SPRINKLER SYSTEM M S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports malleable srewed specials such as M S Reducers,Tees, elbows, flanges. Including cutting,
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationA guide to consumer unit and wiring accessory solutions to meet the demands of general housing installations.
MEM Memera Consumer Units and Wiring Accessories Specification for general housing installations A guide to consumer unit and wiring accessory solutions to meet the demands of general housing installations.
More informationOur objective is to deliver quality electrical materials and services to construction and housing projects that are of the highest quality.
Electra has been partnered with renowned lighting, ventilation, wiring accessories, and electrical system manufacturers since 1965. Our manufacturers and suppliers are known for their quality, creativity,
More informationItem/clause/Page no. Description as per tender. To be read as
Date- 02.11.2012 Amendment-2 Work - Tender for SITC of HT/LT substation equipments installation and allied electrical works for lecture theatre complex, FCI campus, University of Allahabad, Allahabad.
More informationHEAD OFFICE, SECURITY DEPARTMENT
BANK OF INDIA HEAD OFFICE, SECURITY DEPARTMENT RATE TO BE QUOTED BY THE VENDOR Sr. no. Description Make Model Unit Rate Tax Total Amount I BURGLAR ALARM SYSTEM A Burglar/Intruder Alarm System.B Control
More informationTOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING
ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND SR. Description QTY UNIT GROUP A AIRCONDITIONING 1 Supplying and erecting split type room Airconditioning unit 1.5 TR 3/5 star capacity 230/250V,
More informationGroup THE ALI MIRZA GROUP OF COMPANIES CIVILCO OTHER GROUP COMPANIES
Group THE ALI MIRZA GROUP OF COMPANIES Ali Mirza Group, established in 1974, is a leading business group, incorporated. in the Sultanate of Oman with branches in Dubai. It functions in core infrastructure
More informationControl Panel Engineering and Commissioning Instructions
Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement
More informationElement D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More informationFire detection and alarm
Fire detection and alarm Aesthetic Install all cabling and cable containment neatly and unobtrusively, meeting the highest electrical industry installation standards. Neatly lay and securely fix cables.
More informationKTDC/EW/RD/ELE/Sign Boards/AE(E)-1/02/ QUOTATION NOTICE
KRALA TOURISM DVLOPMNT CORPORATION LTD (A Government of Kerala Undertaking) ngineering Wing, Mascot Square, Thiruvananthapuram 695 033 Phone: 2318976, 2721243 Fax: ++91-471-2316168 website: www.ktdc.com
More informationELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET
Candidate Code No. EASQ 3017 For Board Use Only Result Date Int Result Date Int ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ
More informationAddressable NAC Output Module D327A
Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,
More informationFloat Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input
Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input April 2006 SCR-SCRF Utility & General Industry Switchgear Alarm Systems Engine Starting Railroad Emergency
More informationGasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.
Gasflag Single Channel Control Panel Alarm Only Apparatus Installation, operating and maintenance instructions, M07225 Issue 2 1/07/05 Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business
More informationManual / Handbuch Spare parts list / Ersatzteilliste
Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a
More informationQ1. Carefully read the following extract from a safety leaflet. Then answer the questions.
Q1. Carefully read the following extract from a safety leaflet. Then answer the questions. An RCD adaptor is an automatic safety switch. It should be used when there is a particular risk of electric shock.
More informationInstruction Manual WARNINGS
Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Test Centre 15 Progress Road Eastwood Leigh-on-Sea Essex SS9 5JA Contact: Mr S Bailey Tel: +44 (0)1702 425738 E-Mail: stuart.bailey@honeywell.com
More informationELECTRICAL AND COMMUNICATION INSTALLATION DESIGN IN AN OFFICE COMPLEX
ELECTRICAL AND COMMUNICATION INSTALLATION DESIGN IN AN OFFICE COMPLEX PROJECT INDEX: PRJ017 BY F17/1765/2006 MUTUMA WALTER MURIMI SUPERVISOR: PROF. E. MWANGI EXAMINER: DR. J. MBUTHIA DATE: 27 th MAY 2011
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More informationNIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication
NIBE VVM 300 all in one indoor unit Intelligent hot water VVM 300 is designed for connection and communication with outdoor heat pump F20XX of 6 kw, 8 kw and 10 kw. Water volume 280 litres, of which 155
More informationInstallation and user manual for the BiWire / Conventional Repeater Panel
Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....
More informationRequirements for Electrical Installations
BRITISH STANDARD BS 7671:2018 Corrigendum (December 2018) Requirements for Electrical Installations IET Wiring Regulations Eighteenth Edition The Institution of Engineering and Technology and BSI NO COPYING
More informationANALOGUE ADDRESSABLE FIRE DETECTION
Notes to Installer EMC Compliance and LVD Compliance Cables ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Loop Circuit Connections Standalone System Installation Installation Manual Version 3.3X
More informationFIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4
FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT -201-7-3 Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3
More informationENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI
FIRE PROTECTION 1 G.I.PIPES Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 3589 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts
More informationTelecity. Table of Contents. Page. Section 3.2
1 3.2 System Descriptions Table of Contents 3.2 SYSTEM DESCRIPTIONS... 3 3.2.1 General Notes... 3 3.3 Power Distribution MV... 4 3.3.1 Incoming Supply... 4 3.3.2 MV Switch room... 4 3.4 Power Distribution
More informationThe works comprise the complete supply and installation of new Electrical Engineering Services to the site comprising:-
3.0 ELECTRICAL SPECIFICATION 3.1 SCHEDULE OF WORKS 3.1.1 Introduction The works comprise the supply and installation of new Electrical Services within the refurbishment of an existing warehouse to form
More informationSmoothflow Student Fume Cupboard Installation Instructions
Calibre Solutions Ltd 37 Manurere Rise, RD1 Matakohe 0593 Freephone: 0800 422 542 Phone: +64 21 684 273 Fax: +64 9 813 1319 Smoothflow Student Fume Cupboard Installation Instructions Refer Numbered Installation
More informationTONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY
LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY 1 1A. POWER DISTRIBUTION SYSTEMS a. EXECUTIVE SUMMARY b. SUMMARY DESCRIPTION
More informationANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.
ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut
More informationMANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX
MANUAL OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX 1) Technical Specifications: (100VA, 200VA, 300VA) 2) Introduction 3) Construction 4) Operation and maintenance a) Operating Procedure b)
More informationGreen Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions
Green Line HRX Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S, HRX-B, HRX-FP, HRX-BFP, HRX-FS, HRX-FB, HRX-FFP and HRX-FBFP These instructions
More information