1 1 Texas Fire Chiefs Association DOCUMENT SUBMISSION FORM Candidate Department: Coppell Fire Department Best Practice Standard: 6.04 (insert the Best Practice Standard you are working on - example 1.01 ) Proofs of Compliance Submitted: --Copy of written directive --Copies of pre-fire plans for commercial occupancies Submitted By: Gregg Loyd Date: 10/1/2013 Evaluator s Review Evaluator: Date Accepted:

2 2 Coppell Fire Department Standard Operating Guidelines SOG# Pre-Incident Planning Effective Date: 08/01/2013 Fire Chief: Revised Date: 10/1/2013 Purpose: Scope: To establish a guideline for the Pre-Incident Planning This policy applies to all members of the Fire Department Directions: 1. Pre-incident plans will be performed to gather information about occupancies for members of the Coppell Fire Department to utilize during a fire or other emergency incidents. 2. Occupancies will be selected by the Fire Prevention r. Company rs can request particular occupancies for specific training purposes based on occupancy type, construction type, or general curiosity. 3. The pre-incident plans will be set up giving the occupant advance notice of the fire departments intentions. 4. Fire Prevention will maintain a monthly summary of completed pre-incident plans. 5. Fire Prevention Division will place pre-incident plan event on FireHouse calendar. 6. Time, location, and meeting place will be identified within the Notes tab of FireHouse calendar. 7. During the facility pre-incident plans, if a member encounters any condition(s) that pose(s) a threat of fire or life safety, they will be immediately reported to the officer on site. For pre-incident plans of buildings under construction, members will be expected to wear appropriate personal protective equipment. 8. Crew integrity is recommended so all persons receive the same information. Page 1 of 2

3 3 9. Each pre-incident planned facility will have the appropriate information assembled for future use. At a minimum, the following information must be provided: a. All fire/life safety related equipment. b. Construction type. c. Potential hazards/hazardous materials. d. Building dimensions. e. Significant exposures. f. Directional (orientation) arrow. g. Aerial photo from GIS or Google Maps. 10. Fire Prevention will maintain the map book and address index. The map book is located in the Battalion Chief s vehicle. An additional pre-incident planning map will be placed in the appropriate fire pump/riser room near the fire alarm control panel. Page 2 of 2

4 4 Facts: *Solar Panels = 8000 lbs *12 10 Panels *501 lbs added to each panel to make panels resist 90 mph winds *Turning off solar breaker box will turn solar power off to bldg *Allow 5 minutes for power to come down after turning off breaker. *Conduit from panels to inverter is always hot if sun is shining. (360 Volts DC). *Panels can be covered with tarps during daylight to decrease power to inverter. *Solar power is not stored 1001 E. Sandy Lake Universal Academy Solar Panels (4000 lbs) Total 8000 lbs Solar Panels (4000 lbs) Conduit carrying 360 DC Volts Inverter DC Switch 60 ft Breaker Box 3ft

5 5 E. Sandy Lake MacArthur Roof Hatch (Solar Panels) Solar Breaker Box / inverter 400 N Riser Riser Universal Academy FACP / KnoxBox =Overhang Riser Access Door 750

6 6 KNOX BOX N FDC FA Annunciator Server Room FACP 1080 W. BETHEL Electric risers TEST KITCHEN 161 WAREHOUSE Freezer Gas Cooler 231

7 7 Wrangler Dr. Server Room Upstairs Gas Lobby Dr 7 Dr 6 Lake Shore Dr. N Overhead Doors Electric Dr 8 Dr 9 Dr 10 Display Main Fire Alarm Panel Suite 100 (Gemmy) Display Rack Storage Kitchen Rack Storage Suite 150 (TNG) Suite 175 (Texas Dreams Gymnastics) Dr 2 Dr 3 Dr 4 Dr Ft. Photo Shop Dr 11 Pump Room / Knox Box Classrooms FDC also supplies Elect Panels Dr Ft. Lobby Note: Fire pump also supplies 101 Wrangler & 1201 S, Beltline

8 Airline Dr. 8 N Gates 2 Transformers Gen. Main Electrical Open Cubes Quad A North Entrance Dock Raised Floors Quad B S. Beltline Security Elect. Room Elect. Room FACP West Entrance East Entrance FDC Risers Remote Annunciator Corridor to FACP Storage Room Knox Box Open Cubes Roof Access Quad D Elect. Room South Entrance Open Cubes Quad C Elect. Room =Hose Valve *No gas to this building

9 N 9 Gates Gates Rooms Rooms Classrooms Courtyard Gates Wet System Risers (access through office) Rooms Day School 436 Gymnasium (Total Length) 468 Samuel Chapel Basement / Balcony Access Door Dry system risers in basement Grated outside air from basement E. Sandy Lake * * Sanctuary Narthex Sanctuary * * FACP Balcony access only 2 Exhaust Fan Switches in bsmt elect room Sanctuary s Iron Fence Gate FDC Dry System for 180 Samuel FDC Knox Box FACP Access FDC (700 Sandy Lake) Gas Kitchen * Most electrical panels located in basement = Electrical is in basement = Basement = Crawl Space = Only sanctuary door with card reader = Crawl space smoke fans 180 Samuel (St. Ann Parish)

10 N Stairwell at Room C105 Knox Box / EPO Stairwell at Room A105 Hood Suppression System 500 Stairwell Next To Library s FACP Cafeteria Awning Kitchen Awning Gym Riser Room Main Electrical Stairwell at Room B105 = 2 nd Floor Gas All mechanical rooms will access catwalks Heartz Rd. FDC

11 11 N 350 Stairs Stairs 2nd Floor Classrooms Air Handlers 2nd Floor Classroom Electrical Room 1 st Floor 1 st Floor Classrooms Stairs Sanctuary 1 st Floor Ansul System 2nd Floor Kitchen / Cafeteria Reception Desk 1 st Floor 1 st Floor Classrooms Stairs Elevator Elevator Controls Exercise Equipment 2nd Floor 2nd Floor Classroom Air Handlers 2nd Floor Classroom FA Panel / Riser (1 st Floor) Stairs 140 Knox Box FDC

12 Main Electrical Doors N (Other side of shrubs) Gas 500 FDC Knox Box Generator Battery Charging FACP/ Pump Room (Door # 27) Elevated Work Areas North platform access stairs South platform access stairs Wall With Openings Risers Doors Pre-Action System Doors Main Doors 1-9 Loading Docks Northpoint Sandy Lake

13 13 Pump Room Door North Pump Room Knox Box Mezzanine Allstate 20 N Suite 40 Entry FACP BFS #40 BFS Warehouse Suite 40 Mezzanine Stairs Allstate Warehouse Suite 20 Allstate Warehouse Suite 20 Door 7 Knox Box Door 6 FFDO Ste 30 (Access) Mezzanine FFDO Suite 30 BFS Warehouse Suite 40 ODW Warehouse Suite 10 Door 21 Electrical Mezzanine Stairs Ammunition Room (800,000 Rounds) Door 26 South Pump Room Pump Room Door Airline Dr Knox Box ODW 10 Gas Airbag Explosives Airline

14 14 Airline Dr. FACP/ Knox Box N Lobby Mezzanine Door 1 Boiler Riser Door 2 Boiler Emer Shut Down Switch Door 5 Chain Link Multiple Skylights Fan Switches Main Electrical Dryers HazMat Drums Gas Roof Access FDC Door 4 Elevated Clothes Bags Area Door 3 (G&K Services)

15 15 Main Electrical 575 N 2 public hydrants south of building on W. Bethel 300 Door 8 Hose valve Empty Door 5 Hose valve Hose Valve Door 9 Door 3 Hose valve Exhaust Fans Along West Wall Hose Valve Hose Valve Door 11 Hose Valve Rack Stock is Very Heavy!! Consists of Ball Bearings. Repair Room Door 1 Hose valve Pump Roof Access Room FACP Hose Valve Door 12 3 public hydrants east of building on Royal Gas Main Hose Valve Door 13 FDC Knox Box

16 150 E 16 Beltline (Church of Christ) N Northlake Dr. FDC Gas Beltline No Pavement Electric Risers 5, E. Beltline (Ingles) Riser 4 PIV s Riser 3 Dr 7 Dr 6 Gas Dr 5 Dr 4 Dr 3 Warehouse office Numerous Skylights Riser Numerous Skylights NO PAVEMENT Main Riser FACP Knoxbox Stairs Upstairs Room Bldg 2 Bldg 3 Bldg 4 Risers 1, 2 Door 12 Door 13 Door 14 Door Dr 2 Dr 1 Numerous Skylights Sawdust Collection Main Northlake Dr. Artistree

17 17 N FIRE LANE FIRE LANE 1130 Ft Gas Ft FIRE LANE Opticom gate To Hwy Battery Station 28 28a 29 Roof Hatch Pump Room FACP Knoxbox Electrical Break Room a FIRE LANE Warehouse is all open FDC FIRE LANE 10 Clean Room W. Sandy Lake FIRE LANE Opticom Gate 944 W. Sandy Lake

18 Royal 18 N W. Bethel Riser Compactor Riser 11 Main Pre-action Panel Pre-action Sprinklers Conveyor System Pump Room FACP Rack Storage Exterior Roof Access Electrical Room Electrical Riser Room Riser Aerosol Cage Gas KnoxBox Compactor FDC Electrical 1200 **All Red Hydrants Are Pressurized

19 19

20 20

21 21

22 22

23 23

24 24

25 25

26 26

27 27

28 28 65,000 SF.

Osceola County Department of Fire Rescue and Emergency Medical Services

Osceola County Department of Fire Rescue and Emergency Medical Services St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner

More information

A GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS

A GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS A GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS 1. Sketch Each Floor 2. Show Roof access of venting devices 3. Show approaches to the facility 4. Indicate the size of the facility (Length and Width) 5.

More information

Plan Review Check List Fire Alarm System

Plan Review Check List Fire Alarm System Plan Review Check List Fire Alarm System EXCELSIOR FIRE DISTRICT 241OO SMITHTOWN ROAD SHOREWOOD, MN 55331 Alarm system must be installed according to NFPA 72, 2010 Edition, National Fire Alarm and Signaling

More information

PLATTEVILLE MIDDLE SCHOOL

PLATTEVILLE MIDDLE SCHOOL Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle

More information

Business Fire Inspection. City of Guadalupe

Business Fire Inspection. City of Guadalupe Business Fire Inspection City of Guadalupe Intent Provide general information on the California Fire Code (CFC) and City of Guadalupe Municipal Code (GMC) requirements. Provide information and the most

More information

PLAN REVIEW SUBMITTAL GUIDE

PLAN REVIEW SUBMITTAL GUIDE PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide

More information

Denver Fire Department Fire Prevention Division

Denver Fire Department Fire Prevention Division /A 505.1 505.1 Address: Clearly marked from street, Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Address identification characters shall contrast with their background. Each

More information

GENERAL AREAS OF INSPECTION

GENERAL AREAS OF INSPECTION This information is intended to assist you in preparation for the annual high-rise inspection. This is not a complete list and the Inspector may identify other conditions or issues in the building that

More information

AUTOMATIC FIRE SPRINKLER SYSTEMS

AUTOMATIC FIRE SPRINKLER SYSTEMS MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system

More information

Community Development Department Commercial Permit Application

Community Development Department Commercial Permit Application Commercial Permit Application Permit # Property Project Information Address Suite # Business Name Parcel # Fire Department County Type of Improvement (check all that apply) New Addition Alteration Repair

More information

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO 80303 303-494-3735 Contractor s Checklist and Installation Guide TABLE OF CONTENTS Fire Protection Narrative........... 3

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT

More information

New Construction Fire Inspection Process

New Construction Fire Inspection Process New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific

More information

Certificate of Occupancy Application

Certificate of Occupancy Application Certificate of Occupancy Application Mailing Address: Town of Sunnyvale 127 North Collins Road Sunnyvale, Texas 75182 Phone: 972 203 4188 Project Information $50.00 permit fee Square Footage: Name/Description:

More information

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project

More information

CIVIC CONDOMINIUM PREVENTIVE MAINTENANCE SCHEDULE

CIVIC CONDOMINIUM PREVENTIVE MAINTENANCE SCHEDULE Index No. Category/Component DescripCon Doors & Windows DW- 1 Door Hardware & Closers X DW- 2 Exterior Metal Doors X DW- 3 Garage & Loading Ramp Doors DW- 4 Interior Wood & Metal Doors X DW- 5 Storefront

More information

Fire Sprinkler Submittal Requirements and Acceptance Testing

Fire Sprinkler Submittal Requirements and Acceptance Testing Lubbock Fire Marshal s Office 1601 Mac Davis Lane Lubbock, Texas 79401 806-775-2646 Fax 806-775-3508 fireprevention@mylubbock.us Fire Sprinkler Submittal Requirements and Acceptance Testing To all Registered

More information

THE 2016 ANNUAL FIRE SAFETY REPORT. Including Statistics for the 2015 Calendar Year. Prepared by: Ron Crane Director of Safety & Security

THE 2016 ANNUAL FIRE SAFETY REPORT. Including Statistics for the 2015 Calendar Year. Prepared by: Ron Crane Director of Safety & Security THE 2016 ANNUAL FIRE SAFETY REPORT Including Statistics for the 2015 Calendar Year Prepared by: Ron Crane Director of Safety & Security Revised: September 27, 2016 THE ANNUAL CAMPUS FIRE SAFETY REPORT

More information

Woodvale Pentecostal Church

Woodvale Pentecostal Church FIRE SAFETY PLAN For Woodvale Pentecostal Church Nepean, Ontario Revised May 2016 INDEX This index is to facilitate and organize easy reference for the Fire Safety Plan CHAPTER A CHAPTER B CHAPTER C CHAPTER

More information

I. It shall be the responsibility of the department officers to implement this operating guideline.

I. It shall be the responsibility of the department officers to implement this operating guideline. Procedure Effective Date Rescinds HIGH RISE INCIDENTS New Reference FIRE CHIEFS ASSOCIATION OF CENTRAL OHIO Page 1 of 11 NORWICH TOWNSHIP FIRE DEPARTMENT SOG# 8 Purpose: The purpose of this procedure is

More information

GARDEN GROVE FIRE DEPARTMENT

GARDEN GROVE FIRE DEPARTMENT GARDEN GROVE FIRE DEPARTMENT PRE-INSPECTION CHECKLIST PROGRAM FOR SCHOOLS The Garden Grove Fire Department provides an annual school life safety inspection each year to protect lives and property in the

More information

Fire Prevention Bureau INFORMATION PACKAGE

Fire Prevention Bureau INFORMATION PACKAGE Fire Prevention Bureau INFORMATION PACKAGE Evanston Fire & Life-Safety Services 909 Lake Street Evanston, IL. 60201 Phone: 847-448-4311 Fax: 847-866-8729 Fire Chief: Brian Scott 847-866-5925 bscott@cityofevanston.org

More information

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin The purpose of a monthly self-inspection program is to identify unsafe conditions in the work environment and unsafe employee actions. Management can then correct these safety hazards, reducing the potential

More information

S AGE E NGINEERING A SSOCIATES, LLP

S AGE E NGINEERING A SSOCIATES, LLP S AGE E NGINEERING A SSOCIATES, LLP 1211 Western Avenue Albany, NY (518) 453 6091 F (518) 453 6092 Kingston Library Mechanical and Electrical Systems Field Report Date of Visits: Mechanical - September

More information

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District HOLUM EDUCATION CENTER Architectural The existing building has approximately 41,823 square feet and sets on a lot about 4.14 acres in size. Parking lots are located along the east and west sides of the

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Fire & Life Safety Requirements For Fire Department Access and Water Supplies

Fire & Life Safety Requirements For Fire Department Access and Water Supplies Fire & Life Safety Requirements For Fire Department Access and Water Supplies This brochure is being provided as a resource only. The items listed inside are the requirements most generally cited on plans

More information

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT FIRE FOR 75 Fox Street Building OCTOBER 2014 Report for Department of Infrastructure Development Fire Services Preliminary Report:

More information

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up)

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up) GWINNETT COUNTY Department of Fire & Emergency Services Office of the Fire Marshall S001 Access Aisle (Car) S005 S010 S015 S020 S025 S030 S035 S040 S045 S050 S055 S060 S065 S070 S075 S080 S085 Access Aisle

More information

RED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information

RED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information RED CONTRACTOR S BOOK Fire Department Access and Design Engineering Information Orange County Fire Rescue Department An Accredited; Class One Department OFFICE OF THE FIRE MARSHAL David G. Kilbury, Fire

More information

HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE)

HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE) HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE) Administrative and General Building Requirements Safety reference plans (1) Fire alarm audibility (10) Alcohol hand-rub-dispensers (19) School safety

More information

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:. 2012 B.C. Building Code Checklist (Division B Part 3) This checklist is provided as a reference only. The submission of this checklist with a Building Permit application should not be considered as a substitute

More information

Commercial Remodel/ Add On Rules and Regulations

Commercial Remodel/ Add On Rules and Regulations Commercial Remodel/ Add On Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I-45 North Shenandoah, Texas 77381 281-298-5522 www.shenandoahtx.us Construction

More information

Commercial Rules and Regulations

Commercial Rules and Regulations Commercial Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I 45 North Shenandoah, Texas 77381 281 298 5522 www.shenandoahtx.us Construction Documents Submit

More information

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable)

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable) APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable) CITY OF HALTOM CITY, TEXAS, 5024 BROADWAY AVE., HALTOM CITY, TEXAS 76117 Tel~hone - 817-222-7730 FAX - 817-222-7739 *** C/O APPLICATION

More information

400 Park Road, Watertown, CT

400 Park Road, Watertown, CT Industrial & Commercial: A Yankee Tradition Established in 1954 400 Park Road, Watertown, CT SUMMARY Modern class A office, manufacturing, warehouse, and laboratory space in approximately 140,000 SF building.

More information

SAMPLE FIRE SAFETY PLAN. ABC Manufacturing Ltd. 123 Main Street Steinbach, Manitoba. Prepared by: John Smith Last reviewed: Bill Jones 2014

SAMPLE FIRE SAFETY PLAN. ABC Manufacturing Ltd. 123 Main Street Steinbach, Manitoba. Prepared by: John Smith Last reviewed: Bill Jones 2014 SAMPLE FIRE SAFETY PLAN ABC Manufacturing Ltd. 123 Main Street Steinbach, Manitoba Prepared by: John Smith 2011 Last reviewed: Bill Jones 2014 Page 1 of 19 Table of Contents 1. Building Information 2.

More information

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL SECTION 15100 PART 1 GENERAL THIS IS A DESIGN GUIDE NOT A SPECIFICATION Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL HVAC SYSTEMS APPLICATIONS 1.1 SCOPE: The intent of this

More information

Fire Protection Coffee Break Training May 2016

Fire Protection Coffee Break Training May 2016 Fire Protection Coffee Break Training May 2016 Introduction High-Rise Requirements Questions and Answers Agenda Overview Site Fire Access Aerial Access Power/Back-up Power Elevators and Access Sprinklers

More information

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal

More information

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee Fire Service Considerations A Primer for Building and System Designers Society of Fire Protection Engineers Fire Service Committee Version 1 October 15, 2012 Target Audience Any of these designers without

More information

Building Self-Inspection Program

Building Self-Inspection Program Building Self-Inspection Program www.tridentinsurance.net Lines of Business: Property, General Liability, Worker s Compensation, Public Official Liability Risk Control Strategy/Key Issues: Reduce physical

More information

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.14 Control Number: A.0 Effective Date: 9/14/11 TITLE:

More information

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.

More information

FORT ERIE SECONDARY SCHOOL FACILITY INFORMATION. Lake Erie Corridor Secondary Schools Accommodation Review

FORT ERIE SECONDARY SCHOOL FACILITY INFORMATION. Lake Erie Corridor Secondary Schools Accommodation Review FORT ERIE SECONDARY SCHOOL FACILITY INFORMATION Lake Erie Corridor Secondary Schools Accommodation Review November 2012 LAKE ERIE CORRIDOR SECONDARY SCHOOLS ACCOMMODATION REVIEW Fort Erie Secondary School

More information

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET 1 SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT

More information

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Code Sections: 105.7.18 Control Number: A.0 Effective Date: TITLE: SCOPE:

More information

SITE PLAN REVIEW APPLICATION AND CHECKLIST

SITE PLAN REVIEW APPLICATION AND CHECKLIST SITE PLAN REVIEW APPLICATION AND CHECKLIST PROJECT SUMMARY: Project Name: City/ETA Location: City ETA (Application fee & number of copies needed are based on location) Property Location (Legal Description

More information

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building Facility Condition Assessment Summary Report British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building Submitted by: VFA Canada Corp. Burnaby Centre 4211 Kingsway Burnaby, BC V5H 1Z6

More information

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour. Everything a firefighter wants to tell a design professional or building code official, in one hour. 1 2 3 1 4 The job of the fire department is to put the wet stuff on the red stuff. 5 Job #1. of the

More information

Chapter 2: Identification, water and access

Chapter 2: Identification, water and access Chapter 2: Identification, water and access As you are approaching the occupancy to be inspected, take note of building and fire protection services. Put yourself in the shoes of a first arriving company

More information

Fire Inspection Program

Fire Inspection Program ANN ARBOR FIRE DEPARTMENT Fire Inspection Program OUR MISSION: The mission of the Ann Arbor Fire Department is to efficiently and professionally protect the residents and visitors of the City of Ann Arbor

More information

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP

Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP Sec. 54.1. Group B occupancies. 54.2. Classification. 54.3. Nursery schools, day care centers and the like. 54.4. Separation

More information

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly. SAFETY GENERAL Buildings must be designed according to building and fire safety codes and other regulatory standards at the time of construction. However, such codes and standards are continuously changing.

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT FIRE FOR 69 PRESIDENT SEPTEMBER 2014 Report for Department of Infrastructure Development Fire Services Preliminary Report: 69

More information

SAGU AMERICAN INDIAN COLLEGE 2018 ANNUAL FIRE SAFETY REPORT INCLUDING STATISTICS FOR THE 2017 CALENDAR YEAR PREPARED BY:

SAGU AMERICAN INDIAN COLLEGE 2018 ANNUAL FIRE SAFETY REPORT INCLUDING STATISTICS FOR THE 2017 CALENDAR YEAR PREPARED BY: SAGU AMERICAN INDIAN COLLEGE 2018 ANNUAL FIRE SAFETY REPORT INCLUDING STATISTICS FOR THE 2017 CALENDAR YEAR PREPARED BY: Nicholas Zamorano Director of Enrollment and Student Development Revised: September

More information

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required

More information

Q-0751 Principles of Building Construction Resources

Q-0751 Principles of Building Construction Resources Q-0751 Principles of Building Construction Resources U.S. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY U.S. FIRE ADMINISTRATION NATIONAL FIRE ACADEMY This page intentionally left

More information

2012 B.C. Building Code Compliance Review (Division B Part 3)

2012 B.C. Building Code Compliance Review (Division B Part 3) Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS:...... PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting

More information

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION BUILDING ADDRESS: 70 74 Morningside Drive East Campus BUILDING OWNER / REPRESENTATIVE: Name: Trustees of Columbia University Address: 535 West 116 th

More information

BID INFORMATION LIST Crossroads East N. Scottsdale Road, #105 Scottsdale, AZ Rev

BID INFORMATION LIST Crossroads East N. Scottsdale Road, #105 Scottsdale, AZ Rev BID INFORMATION LIST Crossroads East 18511 N. Scottsdale Road, #105 Scottsdale, AZ 85255 Rev.1 12-20-17 SITE CONTACTS: LANDLORD CONSTRUCTION CONTACT Diversified Partners Kevin Gantner Office - (480) 947-8800

More information

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION. Type of Construction: Combustible Non-Combustible

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION. Type of Construction: Combustible Non-Combustible FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION BUILDING ADDRESS: Sigma Phi Epsilon (SPE) - 550 West 113 th Street BUILDING OWNER / REPRESENTATIVE: Name: Trustees of Columbia University Address: 535

More information

Building and Grounds Self-Inspection Program

Building and Grounds Self-Inspection Program www.alterisus.com Building and Grounds Self-Inspection Program Each building and its accompanying grounds should be inspected at regular intervals, ideally on a monthly or quarterly basis. In this way,

More information

CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT 5500 WILSHIRE AVE NE ALBUQUERQUE, NM 87113

CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT 5500 WILSHIRE AVE NE ALBUQUERQUE, NM 87113 CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT DRAWING INDEX COVER SHEET G-101 FIRST FLOOR CODE ANALYSIS G-102 SECOND FLOOR CODE ANALYSIS G-103 CAFETERIA CODE ANALYSIS D-101 FIRST FLOOR DEMOLITION PLAN

More information

BCCO TRAINING FOR CONTRACTORS

BCCO TRAINING FOR CONTRACTORS BCCO TRAINING FOR CONTRACTORS Printed or Saved Mygov Virtual Inspections PERMITS 2 APPLYING FOR PERMITS Please visit our Website at buildingcodecompliance.ocps.net for valuable information regarding the

More information

TRANSMISSION AND DISTRIBUTION SUBSTATIONS

TRANSMISSION AND DISTRIBUTION SUBSTATIONS A.U.C. 338, ADDENDUM 2 October 20, 2011 1. INTRODUCTION 1.1 Transmission Substations receive 345,000 volts from generating stations and then step it down to 138,000 volts for delivery to Distribution Substations.

More information

APPENDIX H (DESIGN SUBMISSION CRITERIA)

APPENDIX H (DESIGN SUBMISSION CRITERIA) APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation

More information

Edward Jenner Elementary Academy of the Arts

Edward Jenner Elementary Academy of the Arts Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

AUSTIN FIRE DEPARTMENT SIA PROCEDURES FOR ANNUAL TESTING OF BUILDINGS WITH STAIRWELL AND VESTIBULE PRESSURIZATION SYSTEMS

AUSTIN FIRE DEPARTMENT SIA PROCEDURES FOR ANNUAL TESTING OF BUILDINGS WITH STAIRWELL AND VESTIBULE PRESSURIZATION SYSTEMS AUSTIN FIRE DEPARTMENT SIA PROCEDURES FOR ANNUAL TESTING OF BUILDINGS WITH STAIRWELL AND VESTIBULE PRESSURIZATION SYSTEMS Building stairwell and vestibule pressurization systems must be retested and recertified

More information

Environmental Health & Safety

Environmental Health & Safety Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

GOLDEN FIRE DEPARTMENT FIRE & LIFE SAFETY DIVISION

GOLDEN FIRE DEPARTMENT FIRE & LIFE SAFETY DIVISION GOLDEN FIRE DEPARTMENT FIRE & LIFE SAFETY DIVISION 911 10 th Street Golden, Colorado 80401 303-384-8094 Contractor s Permit & Inspection Guide *Note: this is not an all-inclusive list of requirements;

More information

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD LIGHTING FIXTURES AND CIRCUITRY & SWITCHING SECONDARY SCHOOLS 1. GENERAL 1.1.1. Consultants MUST prepare a Summary of Fixtures which will include catalogue

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT PIMKIE APPARELS LTD. PLOT # 328, BLOCK # F, TONGI, INDUSTRAL AREA OTHER FACTORIES: NONE May 25, 2014 Page 2 SUMMARY was surveyed for fire safety on 5/25/2014 by Hughes Associates,

More information

LEASIDE UNITED CHURCH FEASIBILITY STUDY TORONTO, ONTARIO

LEASIDE UNITED CHURCH FEASIBILITY STUDY TORONTO, ONTARIO LEASIDE UNITED CHURCH FEASIBILITY STUDY TORONTO, ONTARIO Public Presentation October 21, 2018 11:30am Mission The Mission of Leaside United Church is to grow a caring and vibrant spiritual community that

More information

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011 1.0 GENERAL: Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011 1.1 PURPOSE -The intent of this guideline is to provide the requirements for the protection

More information

Brighton Area Fire Authority

Brighton Area Fire Authority 615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following

More information

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY FIRE ALARM INSPECTION AND TESTING SUMMARY PAGE PER 2013 NFPA 72 Inspector: Jim Smith Test Date: 5/22/2014 PROPERTY INFORMATION Name of Property: Windsor Tower Owner of Property: Jim Gibbs Properties Address:

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: The Lane School 500 N Elm St Hinsdale, IL 60521 Survey Date: April 17, 2012 to April 19, 2012 Initial Test

More information

Facilities Management Services

Facilities Management Services Facilities Management Services Operating Budget Facilities Management (FM) receives an Operating Budget each year predicated on funding the routine, predictable costs of cleaning, maintaining,, and repairing,

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED Ashton Elementary School 1 Masonry Repair $ 42,781.50 2 Replace HVAC $ 375,000.00 3 Replace SAT @ Various Locations $ 92,364.00 3 Recoat & Resurface Exterior Paved Play Area $ 135,978.30 3 Various Technological

More information

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: From: Subject: Whom It May Concern Carl Ray Austerman, Fire Marshal Contractor s Guide Welcome to the Glendale Fire Department s Contractors Guide. This

More information

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question. Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy

More information

St. John s University Fire Safety Plan

St. John s University Fire Safety Plan Fire Safety Plan Kelleher Center Kelleher Center page 2 St. John s University Fire Safety Plan Part 1-Building Information Section Kelleher Center 300 Howard Ave. Staten Island, N.Y. 10301 Fire Safety

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

VSC Fire & Security, Inc.

VSC Fire & Security, Inc. JOB#: 12775876 VSC Fire & Security, Inc. 10640 Iron Bridge Road, Suite G Jessup MD 20794 (301) 575-1500 www.vscfs.com Important: Deficiencies, Comments and Explanations any FAIL or NEGATIVE responses are

More information

PART II: New Construction Inspections and Acceptance Testing Procedures

PART II: New Construction Inspections and Acceptance Testing Procedures Stafford County Fire Marshal s Office Handbook for Building/Fire Code Policies and Guidelines PART II: New Construction Inspections and Acceptance Testing Procedures Phone: 540-658-8648 Fax: 540-658-9128

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Mogorkhal, Chowrasta, National University, Gazipur Gazipur Dhaka 09 May 2016 The Alliance for Worker Safety Page 1/13 09 May 2016 Introduction to the

More information

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property Fire Code Maintenance Handbook Fire Prevention Saves Lives and Property 8/10/2006 Our Mission The West Chester Fire Department Loss Prevention Bureau is committed to the safety of its firefighters, and

More information

WPUMC Capital Report Existing Facilities February 19, Maintenance Coordinator George Smit

WPUMC Capital Report Existing Facilities February 19, Maintenance Coordinator George Smit WPUMC Capital Report Existing Facilities February 19, 2017 Maintenance Coordinator George Smit Facility Overview Buildings Sanctuary Building (SB) Sanctuary, Narthex, Lobby Choir Room. Dr. Lee s Office,

More information

Fire/Life Safety Policy

Fire/Life Safety Policy Fire/Life Safety Policy On Campus Student Housing A. Purpose The University supports and maintains a strong commitment to the safety and health of each student living in On Campus Student Housing. The

More information

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate Fire Alarm and Life Safety System Inspection Certificate For City of Rock Hill 757 S. Anderson Rd Rock Hill, AC 29730 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST TENANT IMPROVEMENTS Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;

More information

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics. A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable

More information

Muster Area in North Parking Lot

Muster Area in North Parking Lot Bldg 905 EVAC Routes Facility Evacuation Instructions N E001 MAIN ELECTRICAL M002 BOILER M001 102A 108A 102C 102A 102B 102 107 105 103A Muster Area in North Parking Lot 100 478 LIBRARY 1001 LOBBY ENTRANCE

More information

FIRE DEPARTMENT SYSTEM PERMIT APPLICATION

FIRE DEPARTMENT SYSTEM PERMIT APPLICATION Permit No:_ FIRE DEPARTMENT SYSTEM PERMIT APPLICATION Thank you for submitting plans for the installation or modification of a required fire protection or detection system. Typical review of system plans

More information