HARVARD JOLLY, INC Dr. Martin Luther King, Jr. Street North
|
|
- Mavis Osborne
- 5 years ago
- Views:
Transcription
1 ARCHITECTURE DESIGNING POSSIBILITIES SINCE 1938 STOCKHOLDERS William B. Harvard, J r., AIA Jeffrey E. Cobble, AIA Michael K. Hart, AIA Ward J. Friszolowski, AIA Steven M. Heiser, AIA Alejandro F. Gonzalez, AIA Yvette V. London, AIA Jack Williams, Jr., AIA Paul N. Schnitzlein, AIA Jacquelyn S. Spears, ASID Leslie D. Brunell, AIA Stephen L. Johnson, AIA Philip L.Trezza, Jr., AIA Louis B. Kubler II Charles J. Clees, RL A Howard W. Braukman, AIA Ronald R. Zajac, AIA Maria Harvard Rawls R. John Clees, AIA ADDENDUM NO. 3 STATE COLLEGE OF FLORIDA SERVERY RENOVATIONS HJ Comm. No HARVARD JOLLY, INC Dr. Martin Luther King, Jr. Street North St. Petersburg, FL ADDENDUM NO. 3: December 2, 2014 To be attached to and form a part of the foregoing contract documents for labor, materials and service for renovation of the servery at State College of Florida in Bradenton, Florida. PART 1 REFER TO SPECIFICATIONS: Revisions to food service equipment items K32, K3 and K34. See attached revised specifications. PART 2 REFER TO DRAWINGS: Sheet M1.2: Removed chilled water piping, water cooled condensing unit by others, and associated notes from the drawing. Sheet M2.1: Removed details related to chilled water piping installation. Sheet E1.3: Removed water cooled condensing unit from drawing. Relocated associated circuit to coordinate with new air cooled condensing unit by others. Sheet FS-1 Condensing unit location change: item K34 Sheet FS-2 Item K34 electrical change Sheet FS-3 Item K34 electrical location change Sheet FS-5 Removed note for condensing unit chase above walk-in Sheet FS-W1 Changed condensing unit info on manufacturer s shop drawing to match new air-cooler remote unit PART 3 CLARIFICATIONS: 2714 Dr ML King Jr St N St. Petersburg, FL Not applicable. AAC Page 1 of 2
2 END OF ADDENDUM
3 12/2/2014 State College of Florida Addendum 3 Food Service Equipment Specifications ITEM #K32 WALK IN Quantity: One (1) Manufacturer: American Panel Corporation Walk in cooler with display shelves. See walk in drawing in food service set for details. ITEM #K33 REFRIGERATION COIL Quantity: One (1) Manufacturer: American Panel Corporation Model: CTA Center mount Evaporator Coil ITEM #K34 REMOTE CONDENSER UNIT Quantity: One (1) Manufacturer: American Panel Corporation Model: FFAP-020Z-TFC-072 Preassembled remote air cooled condensing unit with winterization controls, 18 high UL listed stand with UL listed weather cover. FSEC to coordinate final location of condensing unit per sheet E1.3 with GC. FSEC's refrigeration installer to coordinate his routing of refrigerant lines in ceiling to outdoor unit with GC.
4 KITCHEN 152 G DISH- WASHER 158 MECHANICAL 168 Ft. Lauderdale Ft. Myers Jacksonville Orlando Punta Gorda St. Petersburg Tampa AAC LOUNGE 151 STORAGE 136 Comm. No: Date: Drawn: Revised: COVERED ENTRY DESIGN OFFICE LOCATION: 2714 DR. MARTIN LUTHER KING JR. ST. NO., ST. PETERSBURG, FL, 33704, PH: ME3 KAY C. CLEM, P.E. FL LICENSE # 53270
5 Ft. Lauderdale Ft. Myers Jacksonville Orlando Punta Gorda St. Petersburg Tampa AAC DESIGN OFFICE LOCATION: 2714 DR. MARTIN LUTHER KING JR. ST. NO., ST. PETERSBURG, FL, 33704, PH: Comm. No: Date: Drawn: Revised: ME3 KAY C. CLEM, P.E. FL LICENSE # 53270
6 LIQUID TIGHT FLEXIBLE METAL CONDUIT CONNECTOR RIGID STEEL CONDUIT COUPLING FLUSH WITH FINISH FLOOR DIRECT CONNECTIONS TO EQUIPMENT INDICATED BE MADE WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT < SIX FEET IN LENGTH. 2"X4" CAST BOX WITH DEVICE RING AND WEATHERPROOF COVER. DIRECT CONNECTION JUNCTION BOXES SHALL HAVE GASKETED STAINLESS STEEL BLANK COVER. MULTI-POLE RECEPTACLE MAY REQUIRE A 4" X 4" BOX SECURE BOX TO UNISTRUT SUPPORT RIGID STEEL CONDUIT RIGID PVC CONDUIT STUB UP 12 GAUGE GALVANIZED STEEL UNISTRUT SUPPORT MINIMUM 12" DEPTH BELOW CONCRETE SLAB. K34 Ft. Lauderdale Ft. Myers Jacksonville Orlando Punta Gorda St. Petersburg Tampa AAC DESIGN OFFICE LOCATION: 2714 DR. MARTIN LUTHER KING JR. ST. NO., ST. PETERSBURG, FL, 33704, PH: G K6A K6B K8 K10 K9 K9 K14 K48 K43 K6C K18 K13 K25 K15 K68 K28 K67 K66 K16 K64 K64 K26 K32 K60 K61 K53 K53 K54 K39 Comm. No: Date: K60 K61 Drawn: Revised: K56 K57 K64 K64 K58 K33 K67 K68 K58 K74 K74 ME3 BRYAN P. ZAPF, P.E. FL LICENSE # 46141
7
8
9
10
11
Element D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More information23 EA , , , , , , , LF , , ,596.
Mast Arm Traffic Signals at Central Ave. 5th, 6th, 8th & 31st St. Engineering & Capital Improvements Department, City of St. Petersburg, FL Project No.: 11027-112 Bid date: January 10, 2012 Item Description
More informationDES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.
DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT 806 E. Hoffman Street Des Moines, IA 50316 ADDENDUM NO. 1 April 3, 2017 Item 1: Item 2: Item 3: Item 4: See attached sketch showing the
More informationBEVERAGE CONDUIT SYSTEMS
BEVERAGE CONDUIT SYSTEMS MATERIALS CONSULTING INSTALLATION March 2012 Easybar Beverage Management Systems A EASYBAR BEVERAGE CONDUIT SYSTEMS COMPLETE BEVERAGE CONDUIT ROUTING SYSTEMS FOR THE BEVERAGE INDUSTRY
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationPROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER
PROJECT NO. CWA 2013-04 SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER BIDS RECEIVED: CITY HALL, CITY OF BESSEMER TIME: 2:00pm DATE: October 2, 2014 City of Bessemer --------------------------------------------------------------------------------------------------------------------------------------------
More informationINSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)
SECTION 11400 INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS) PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Pre-fabricated, free standing walk-in cooler/freezer rooms, metal clad, designed
More informationDONALD H. BERG, ARCHITECT
DONALD H. BERG, ARCHITECT DVA PROJECT 632-CSI-402 PET/CT ROOM #A0-10 RENOVATION BASEMENT LEVEL, BUILDING 200 ARCHITECT S PROJECT No. 0917-02 ADDENDUM NO. 1 JUNE 25, 2018 Page 1 of 1 ARCHITECTURAL 1. Specifications:
More information9 E. Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition
Addendum NO. 1 Issue Date: October 20, 2016 Project: City of Abilene 10 20 2016 Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition I WILL STAT AMR.DUNCA
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationNOTICE TO ALL FIRMS. Bid RFI Questions and Answers
Purchasing Department 227 West 27 th Street New York, NY 10001 Purchasing Dept. Tel. 212-217-3630 Purchasing Dept. Fax 212-217-3631 Purchasing@fitnyc.edu NOTICE TO ALL FIRMS Date: March 8, 2018 To: From:
More informationVibratone Horns. Models 350 and 450
FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and
More informationFRESH FROM THE KITCHEN FRESH FROM THE KITCHEN
PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY
More informationINSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)
SECTION 11400 INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS) PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Pre-fabricated, free standing walk-in cooler/freezer rooms, metal clad, designed
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)
More informationThird Year Renewal of Three-Year Contract Bid # LR, Fire Extinguisher Service Maintenance Department Florida Fire Services, Inc.
Department of Purchasing 813/ 794-2222 Fax: 813/ 794-2111 727/ 774-2222 TDD: 813/ 794-2484 352/ 524-2222 e-mail: kgoodman@pasco.k12.fl.us December 12, 2007 MEMORANDUM TO: FROM: RE: Honorable School Board
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationAddendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017
Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD 21801 Ph. 410-548-4805 Fax 410-334-3130 Email: purchasing@wicomicocounty.org Addendum # 2 Wicomico County Circuit Court Second Floor
More informationM001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More information10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS
ITEM NO. PROJECT LOCATION DATE QTY. 10-Bilt Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS CONSTRUCTION Models ship within 10 working days after order is received 4" thick
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More information350 Pine Street, Suite 720 Edison Plaza Beaumont, TX Fax
350 Pine Street, Suite 720 Edison Plaza Beaumont, TX 77701 409.866.7196 409.866.1745 Fax Project: Addendum No. 1 FIRE STATION #2 NORTH END CITY OF BEAUMONT 4990 HELBIG ROAD, BEAUMONT, TEXAS BID PROPOSAL:
More informationWall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations
Wall mount refrigeration systems available PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations PRS-2: The Keyword Is Simple Simple Convenience The PRS-2 series combines durable walk-in panels
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationINDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan
30 Greenway, NW Suite 11 Glen Burnie, Maryland 21061 tel 410.528.8899 fax 410.558.6312 www.gbalternatives.com INDEX Page 2 to 7 Electrical Specifications Page 8 Electrical Schemes: Basement Plan Page 9
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this case model and/or the data is not available at this time. SHIPPING WEIGHT --- Weight ELECTRICAL DATA Fans Per High Effciency Fans
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationOHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available at this time. LED lights only. Maximum of 4 rows of Standard Output LED lighted shelves.
More informationConstruction Engineering & Inspection
Construction Engineering & Inspection Serving Florida for 20 Years CEI Engineering Planning Landscape Architecture Urban Design Construction Engineering & Inspection (CEI) I N T R O D U C T I O N Over
More informationO3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose
More informationFMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions
& Discriminating Dispenser Sump & Turbine Sump Brite Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More information6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this model and/or the data is not yet available. LED lights only. Maximum of 6 rows of standard output LED shelves. SHIPPING WEIGHT
More informationroof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required
ITEM NO. PROJECT LOCATION DATE QTY. Quick Ship Walk-In Coolers & Freezers With Matching Refrigeration Systems FREE FREIGHT to domestic U.S. locations and select locations in Canada (consult your Master-Bilt
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationSidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015.
SECTION 000050 - INVITATION AND NOTICE TO BIDDERS PROJECT: OWNER: 3003 Cisco Road Sidney, Ohio 45365 Ohio Presbyterian Retirement Services 1001 Kingsmill Parkway Columbus, Ohio 43229 ARCHITECT: 4685 Larwell
More informationFlorida Energy Extension Service
Florida Energy Extension Service Whole House Fans: Benefits and Description 1 Gary D. Cook 2 In Florida s mild climate whole house fans offer an excellent opportunity to save energy and money when compared
More informationEXHIBIT C DUCTLESS HEAT PUMP SPECIFICATIONS
Page 1 of 5 DUCTLESS HEAT PUMP SPECIFICATIONS 1. NEW EQUIPMENT REQUIREMENTS a. Materials Equipment shall be a split system Ductless Heat Pump (DHP) with an inverter-driven, variable speed compressor, a
More informationIbis Styles Prakanong
UP DRAWING : 160519 458/2425 Moobaan Kulapapruk Tel : +6623381465, Fax : +6623381849 EMail : gm@thanakornholding.com NAME: EQUIPMENT LAYOUT 1:125 K IBS1501 KQ03 UP DRAWING : 160519 458/2425 Moobaan Kulapapruk
More informationINSTALLATION INSTRUCTIONS
9100 SERIES ARCHITECTURAL DRAFT BARRIER WALL AND PEDESTAL MOUNT INSTALLATION INSTRUCTIONS CAUTION: HIGH TEMPERATURES KEEP ELECTRICAL CORDS, FURNITURE, DRAPERIES OR ANY OTHER BLOCKING MATERIAL AWAY FROM
More informationO5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.
More information15900 HVAC INSTRUMENTATION AND CONTROLS
15900 HVAC INSTRUMENTATION AND CONTROLS PART 1 GENERAL - Andover Controls BAS system is the standard for the University, and may be specified as a proprietary item. 1.0 RELATED DOCUMENTS A. Drawings and
More informationCITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT
CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT The City of Mexico Beach is requesting quotes for replacement of 18 lift station control panels. The lift stations range from 2
More informationReplacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus
ADDENDUM FORM INVITATION TO TENDER: 2016-067 ADDENDUM NO: 1 DATE ISSUED: June 23, 2016 ISSUED BY: Monty Thibeault DESCRIPTION: Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus
More informationInstallation Instructions
Installation Instructions TWSD16128PHC-UL Page 1 Introduction The TWSD16128PHC-UL is intended to be used with UL listed WLN / Networking devices both indoors and outdoors and to provide NEM 3R protection
More informationll. Consistency Questions
Our Goal is FOR ALL STAKEHOLDERS TO HAVE A SUCCESSFUL PROJECT with us and that together we keep people and structures safe and buildings economically viable to serve the needs of our community. We strive
More informationBUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
More informationO5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available yet. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More informationFigure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb
Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb Figure 22-2 Enthalpy change through the evaporator Figure 22-3 Two aluminum domestic refrigeration evaporators Figure 22-4
More informationAll Florida plans in the Doing It Right report, ordered by funded ratio: MUNICIPALITY YEAR TYPE FUNDING RATIO KEY WEST 2010 G 110.
All Florida plans in the Doing It Right report, ordered by funded ratio: MUNICIPALITY YEAR TYPE FUNDING RATIO KEY WEST 2010 G 110.9 TEQUESTA 2011 P 105.1 LAKE ALFRED 2010 P 101.4 ROCKLEDGE 2010 P 99.1
More informationEnergy Efficient. Flexible Design Options.
Sandwich Prep Cases The R&D Difference...4 Levels of Customization Energy Efficient. Flexible Design Options. Four levels of customization: Level 1: Choose a standard unit right out of the catalog with
More informationPhone: (856) Providing you with the Fax #: (856) tools you need to grow your business!
Pemberton Twp BOE 691778 Relocation of Two (2) Temporary Classroom Units From the Ft. Dix School Includes:, Concrete, Masonry, Handrails, Carpentry, Plumbing, Electrical Accessories One Egbert street,
More informationO5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---
GENERAL NOTES: "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. If the case is being lined up to an ORS5DM reach-in case, a 21" front
More informationSOUTHVIEW MEDICAL CENTER
PROJECT TITLE: SOUTHVIEW MEDICAL CENTER ENTRANCE VESTIBULE 1997 Miamisburg Centerville Rd. Dayton, Ohio DRAWING INDEX: STRUCTURAL ARCHITECTURAL JUNE 26, 2014 Bulletin #1 - September 12, 2014 AREA OF WORK
More informationField Top Mounted Condensing Unit
Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the
More information900 N. Via Piemonte Ontario, CA
2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:
More informationADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri
ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1 TO CONTRACT DOCUMENTS ENTITLED: PROJECT MANUAL FOR: Women s and Children s Hospital New Water Service Main PROJECT NUMBER: CP172631 ADVERTISEMENT DATE: July
More information135'c " Conduit, 6-#3, 12-#4 Wires Rated-50% 45'c 345'w. 1" Conduit, 3-#4 3.43%VD. 66'c 411'w 4.08%VD. Wires Rated-50% 77'c. 421'w 14 4.
,, Panelboard NEM R enclosure. 90 positions 18K breakers Extend existing concrete base per base details. Paint panel very dark green which is close to the panel across the street. Use existing meter. 58'
More informationBID INFORMATION LIST Crossroads East N. Scottsdale Road, #105 Scottsdale, AZ Rev
BID INFORMATION LIST Crossroads East 18511 N. Scottsdale Road, #105 Scottsdale, AZ 85255 Rev.1 12-20-17 SITE CONTACTS: LANDLORD CONSTRUCTION CONTACT Diversified Partners Kevin Gantner Office - (480) 947-8800
More informationB. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationSpeedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...
SECTION K INDEX Product Description Page Number Speedlock AMC Connectors............................KA Armored Cable Connectors...........................KB-KB5 Metal Clad Cable Connectors.........................KB-KB5
More informationWCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases
WCPT-3 and WCPT-4 Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
More informationParts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH hoshizakiamerica.com Number: 71357 Issued: 11-19-2014 Revised: 11-28-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationHMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3
HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California 95833 September 15, 2016 Woodland Joint Unified School District Spring Lake Area Elementary School HMC No. 3535003.000 DSA Appl.
More informationKITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.
More informationOwner s Manual FS-10/FreshSpa
Owner s Manual FS-10/FreshSpa Table of Contents Product Features................ Page 2 Parts List....................... Page 3 Configuration................... Page 4 Installation.....................
More informationKR Series Air Defrost Unit Coolers Operating and Installation Manual
KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING
More informationMaxLite LED Round Pendant Highbay Series
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationRESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES
SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationFlorida Department of Transportation 1000 NW 111 th Avenue, Room 6203 Miami, Florida
RICK SCOTT GOVERNOR Florida Department of Transportation 1000 NW 111 th Avenue, Room 6203 Miami, Florida 33172-5800 ANANTH PRASAD, P.E. SECRETARY ADDENDUM No. 02 ISSUED ON OCTOBER 14, 2014 TO THE PROJECT
More informationINSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting
More informationA910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
Remote Water Chiller, 8 GPH A9100080-A / A9100080-A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO INSTALLER: 1. Please leave this
More informationAttachment F. Campus Capital Needs Sales Surtax Funded Detail Report
Facility Attachment F Campus Capital Needs Sales Surtax Funded Detail Report Facilities Services 2700 Judge Fran Jamieson Way Viera, Florida 32940-6601 Condition Code Estimate Williams Elementary 1.40
More informationRM with INNOVATOR Doors
RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in
More informationElectrical Equipment & Systems
ELECTRA has been associated with world renowned electrical equipment and systems manufacturers since 1965. Our international manufacturers and suppliers are known for their quality, creativity, unique
More informationDates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000
Executive Summary The Milton S. Hershey Medical Center Academic Support Building is located on The Pennsylvania State University's campus in Hershey, PA. The building is owned by The Pennsylvania State
More informationWhen considering the purchase of a walk-in you most likely will be looking for the following things.
BUYING A WALK-IN COOLER OR FREEZER When making a decision on which walk-in cooler or freezer to buy, there are many things that must be considered. In the following guide we hope to go through all these
More informationADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM
ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT February 29, 2012 RFP NO: 17 PROJECT: Josephine County Justice Center HVAC Upgrades BID CLOSING DATE: NO CHANGE: March 8, 2012 / NOT LATER
More informationDEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and
DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and equipment), and discussions with maintenance personnel
More informationSECTION AIR COILS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More informationCustomer w/gallery N Briarberry Point Beverly Hills, FL 34465
Condo/Villa/Townhome 700189 _Active Customer w/gallery 3847 N Briarberry Point Beverly Hills, FL 34465 (19) L$55,900 Cross Street: Lake Beverly Dr Area: 09 County: Citrus Year Built: 1983 Subdivision:
More informationE Q U I P M E N T S C H E D U L E
28 28 24 37 2x48 2x48 2x48 28 28 27 38 32 36 57 43 43 43 58 3 49 48 4 25 38 33 35 40 39 56 59 30 5 9 7 8 9 0 2 3 3 5 25 4 6 38 46 40 46. 34 29 39 34 54 53 40 42 8 9 20 2 42 7 2 26 26 26 26 23 5 5 50 60
More informationWalk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details
Walk-in Refrigerated Rooms An Overview of Requirements, Options and Construction Details Definition A refrigerated room is a stand alone structure designed to hold products at either a medium temperature
More informationINSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationFMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions
FMP-DVS Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608
More informationSECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:
SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes basic electrical materials and methods including: 1. Conduit, fittings and accessories. 2. Wire,
More informationS T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR
S T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR 3M Electronic Monitoring (Contract Provider) 1838 Gunn
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationINSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK
INSTALLATION AND OPERATING INSTRUCTIONS For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK Congratulations on your purchase of the Reliance Controls Generator Power Transfer
More informationProduct Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW
COD: 2BP8CS00 KEPLERO RGBW,167$//$7,21 *8,'( Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW :$51,1* To ensure a maximum efficient use of the product, read the instructions before
More informationDivision 26 ELECTRICAL TABLE OF CONTENTS
Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More information