Balcony 1/14. Balcony. Rest rooms. Rest rooms Microscopy Room. Computer Lab. Library. Store. Stairs. Stairs. Staff and Meeting room. Lobby.
|
|
- Roland O’Neal’
- 5 years ago
- Views:
Transcription
1 Microscopy Store Computer Library Culture Sample Reception Staff and Meeting room Lobby Lecture Hall Lobby Referral - Existing Second Floor Partitions Referral.Juba..2.dwg Selected spaces for TB Culture oratory - Left Wing - Wubetie, Zebano Worku 1/14
2 To be Demolished Store To be Constructed Smoke Sensor Single socket Outlet Twin Socket Outlet One way Switch Two way switch Blue areas and lines Microscopy D6 X X Staff and Meeting room Referral - Existing Second Floor Layout - Left Wing Referral.Juba..2.dwg Layout plan with selected areas and items for demolishing - Wubetie, Zebano Worku 2/14
3 Referral - Existing Second Floor Cross Sectional View - Left Wing Referral.Juba..2.dwg Cross sectional view - Wubetie, Zebano Worku 3/14
4 Climate Control Distiller Sterilization New fan Placement type Store D4 Type Media Prep Microscopy Training D7 D5 W3 Shower D6 D8 Upright Freezer Platilab 500 v-3 STD Upright Freezer -80oC Cooled Distiller and Deionizer II Exit D1 W1 Culture ROTINA 380R, Benchtop W2 Ante W4 D2 Sample Procesing Type Staff and Meeting room HEPA Filtered Air Extraction HEPA filtered Air Supply W5 Referral - New Second Floor Layouts for TB - Left Wing Referral.Juba..2.dwg Final Layout of the Second Floor Left Wing - Wubetie, Zebano Worku 4/14
5 Climate Control Distiller Sterilization New fan Placement type Store Existing Sanitary Lines Type Media Prep D4 Microscopy Training New Sanitary Lines D5 W3 Shower D6 Upright Freezer Platilab 500 v-3 STD Upright Freezer Cooled -80oC Distiller and Deionizer HEPA Filtered Air Extraction II ROTINA 380R, Benchtop Centrifuge HEPA filtered Air Supply D1 W2 Ante W4 D2 above floor level Sample Procesing W5 W1 Type Staff and Meeting room NOTE 1. Demolished Sink drains, those not reused, must be sealed 2. All sinks must me furnished with elbow tap handle, where handles are at least 250mm in length 3. The existing routes shown may be different from the drawing since all are in the concrete. therefore, all exact routes must first be identified during the courses of demolition Referral - New Second Floor Sanitary Plan for TB - Left Wing Referral.Juba..2.dwg New Layout of the Second Floor TB lab spaces - Left Wing - Wubetie, Zebano Worku 5/14
6 Climate Control Distiller Sterilization 3200w New fan Placement type Store Existing socket outlets Type Media Prep D4 Microscopy Training Socket outlets to be moved from old wall New socket outlets 1P & 3P One way electric switch Two way electric switch & Upright Freezer Platilab 500 v-3 STD Upright Freezer -80oC Cooled W3 Distiller and Deionizer D5 Shower II D6 Exit D1 W1 Placement for Data Box 2.8m Placement for Fire RJ45 Data Connection Outlet NOTE 1. Rerouting of Light lines is to be accomplished in a way that the two ' lights are operated as expressed by the switches by minimizing new line constructions. Provisional outlets box containing 6Pcs of 13A outlets 4 Culture HEPA Filtered Air Extraction Provisional outlets box containing 6Pcs of 13A outlets ROTINA 380R, Benchtop Centrifuge HEPA filtered Air Supply W2 Ante W4 D2 Sample Procesing W5 Type Staff and Meeting room 2. Power for Airhandling unit shall be used either from the old socket line or a new 3Phase socket as located on the diagram depending on its power source demand. 3. Power Supply for the new socket outlets shall be taken from the nearest Distribution board. 4. Data points shall be fed from the 6U Box 5. 6U Box data source shall be from telecom provider Referral - New Second Floor Electrical Plan for TB - Left Wing Referral.Juba..2.dwg SHEET CONTENT: Final location of new and adjusted points of light points, switches, sockets and data - Wubetie, Zebano Worku 6/14
7 Climate Control NOTE Distiller Type Media Prep Sterilization D4 New fan Placement type Microscopy Training Store 1. Selection of direction of entry and path of the air ducts will be choosen after aggreement is reached. 2. Other proposals that need confirmation and verification shall be agreed before ordering of materials D5 W3 Shower D6 Upright Freezer Platilab 500 v-3 STD Upright Freezer -80oC Cooled Distiller and Deionizer II Exit D1 Presssure Status Display of room W1 Thimble Connection Culture Presssure Status Display of room ROTINA 380R, Benchtop Supply Air W2 Ante W4 D2 Sample Procesing Type Staff and Meeting room HEPA Filtered Air Extraction HEPA filtered Air Supply W5 Referral - New Second Floor Air Handling System Plan for TB - Left Wing Referral.Juba..2.dwg Air extraction and supply systems, smoke sensors, gauges - Wubetie, Zebano Worku 7/14
8 Sample Analysis Bacteriology Training Office Molecular I Mol. II Mol. III Washing/ Sterilization Distillation/ Autoclaving Quality Manager Mycology Store Parasitology I Par II Director General Referral - Existing First Floor Partitions Referal.Juba..2.dwg Selected spaces for PCR - Right Wing 1:100 - Wubetie, Zebano Worku 8/14
9 Window Window DW2 Molecular Biology (Area2) A=33.85m² PCR (Area1) A=9.95m² X X To be Demolished To be Constructed Blue areas and lines D7 PCR (Area 3) A=10.4m² Smoke Sensor DW1 D6 Single socket Outlet DW3 Window Twin Socket Outlet One way Switch Two way switch Referral - Existing First Floor Molecular Spaces Layout - Right Wing Referral.Juba..2.dwg Layout Plan with selected areas and items for demolishing - Wubetie, Zebano Worku 9/14
10 Door for DW1, DW2 & DW3 Door for D6 [Reused Door] Referral - Existing First Floor Cross Sectional View of Molecular labs - Right Wing Referral.Juba..2.dwg Cross sectional view - Wubetie, Zebano Worku 10/14
11 DW2 4C Refrigerator -20 Deep Freezer D9 To be Demolished Office A=33.85m² II POST PCR A=27.26m² COBAS AmpliPrep PRE PCR A=26.04m² II COBAS TaqMan 48 Incubator To be Constructed Smoke Sensor Blue areas and lines UPS Chest Freezer Basic oratory Centrifuge #1 Thermomixer type Dead Air Box Single socket Outlet Twin Socket Outlet Shower DW1 DW3 W3 Vortex Centrifuge One way Switch Two way switch Referral - New First Floor Layouts for Molecular - Right Wing Referral.Juba..2.dwg New PCR layout with equipment in place - Wubetie, Zebano Worku 11/14
12 Existing Sanitary Lines DW2 New Sanitary Lines D9 Office A=33.85m² POST PCR A=27.26m² PRE PCR A=26.04m² NOTE 1. Demolished Sink drains, those not reused, must be sealed Shower DW1 DW3 2. All sinks must me furnished with elbow tap handle, where handles are at least 250mm in length 3. The existing routes shown may be different from the drawing since all are in the concrete. therefore, all exact routes must first be identified during the courses of demolition Referral - New First Floor Sanitary Plan for Molecular - Right Wing Referal.Juba..2.dwg Existing and new water supply and drainage routes - Wubetie, Zebano Worku 12/14
13 3 Existing socket outlets DW2 Socket outlets to be moved from old wall -20 Deep Freezer 4C Refrigerator Dedicated Power for D9 Dedicated Power for New socket outlets 1P & 3P Two way electric switch 2x36w Florescent lamp fitting NOTE 1. Rerouting of Light lines is to be accomplished in a way that the two ' lights are operated as expressed by the switches by minimizing new line constructions. & Office A=33.85m² Existing Electric Supply Line 1 POST PCR A=27.26m² 4 Provisional outlets box containing 6Pcs of 16A outlets DW1 COBAS AmpliPrep COBAS TaqMan 48 UPS Chest Freezer 4C Basic oratory Refrigerator 2 SDB1 DW3 PRE PCR A=26.04m² II Incubator Centrifuge #1 type Thermomixer Dead Air Box Vortex Centrifuge 2. Power Supply for the new socket outlets shall be taken from the nearest Distribution board. 3. Provisional Socket box's installation possibility is to be assessed at the time of other sockets installation. 4. Data points shall be fed from 6U Box located at second floor small corridor Referral - New First Floor Electrical Plan for Molecular - Right Wing Referral.Juba..2.dwg SHEET CONTENT: Final location of new and adjusted points of light points, switches, sockets and data - Wubetie, Zebano Worku 13/14
14 HEPA Filtered Air Extracting Pre and HEPA Filtered Air Supply HEPA Filtered Extracted Air DW2 4C Refrigerator -20 Deep Freezer D9 Smoke Sensor Presssure Status Display of room II To be Constructed Smoke Sensor Blue areas and lines Office A=33.85m² II POST PCR A=27.26m² Pre filtered Air Extraction Point Downwards from the ceiling Supply Air PRE PCR A=26.04m² type NOTE DW1 DW3 1. The airflow in theses spaces shall be balanced in a way that air flows from Pre PCR room to Post PCR and no air shall be leaving these spaces to the passage (corridor) Shower s Referral - New First Floor Air Handling System Plan for Molecular - Right Wing Referral.Juba..2.dwg - Wubetie, Zebano Worku 14/14
Bethlehem University 2008 Projects Summary
2008 Projects Summary 2008 Projects Summary In Addition to following up daily engineering related issues and supervising the Maintenance and Security Departments the University Engineer is involved in
More informationSECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard
PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for safety equipment used in or in support of
More informationCommissioning of a Mobile CL3 Laboratory: Lessons Learned
Commissioning of a Mobile CL3 Laboratory: Lessons Learned Kelly Anderson 1, BSO Daryl Boehm 2, Stan Klassen 2, Catherine Robertson 1 1 Safety & Environmental Services; 2 Containment Services, Canadian
More informationFaster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.
Faster UltraSafe Class II Microbiological Safety Cabinets Protection, safety, reliability. And more. BEYOND MINIMUM SAFETY REQUIREMENTS FASTER UltraSafe ULTRA FEATURES Faster UltraSafe Microbiological
More informationFlorence High School / Middle School Page 1 of 3 Florence, WI
Florence High School / Middle School Page 1 of 3 Florence, WI Plumbing Systems Review: The following report is the result of a site visit by Tim Kehoe of Muermann Engineering, LLC that occurred on October
More informationDesign Guidelines Fire Safety in New and Refurbished Buildings
Design Guidelines Fire Safety in New and Refurbished Buildings Introduction All major new or refurbishment projects must comply with the Technical Standards (Scotland) Regulations as a matter of course.
More informationAppendix B. Facilities Assessment Report
Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates
More informationConstruction standards and qualities
Structure The structure of the building is made of reinforced concrete with lattice slabs. An independent technical control body guarantees the perfect execution of the structure, which is also covered
More informationESCO. LabTech America A M P L E SCIENTIFIC CITIZEN SCALE INC LABOMED, INC. WORLD CLASS, WORLD WIDE. Rev.2
ESCO WORLD CLASS, WORLD WIDE CITIZEN SCALE INC LabTech America A M P L E SCIENTIFIC LABOMED, INC. Rev.2 ESCO Technologies Biological Safety Cabinets CO2 Incubators Compounding Pharmacy Equipment Laminar
More informationDONALD H. BERG, ARCHITECT
DONALD H. BERG, ARCHITECT DVA PROJECT 632-CSI-402 PET/CT ROOM #A0-10 RENOVATION BASEMENT LEVEL, BUILDING 200 ARCHITECT S PROJECT No. 0917-02 ADDENDUM NO. 1 JUNE 25, 2018 Page 1 of 1 ARCHITECTURAL 1. Specifications:
More informationSUBJECT: Effective Date: Procedure Number:
SUBJECT: Effective Date: Procedure Number: Facilities Operations/ Utilities and Energy 9/1/2015 FS 2015 UES0002 Services Division of Responsibility Procedure APPLICABILITY/ACCOUNTABILITY: Supersedes: Page
More informationPharmaceutical Facility Design
PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the
More informationElement C3.5 Means of Escape
.5 Means of Escape RRFSO Article 14 Legal Factors Responsible person must ensure routes to emergency exits and exits themselves are kept clear at all times Exits must directly lead to place of safety Safe
More informationG W C C GREENMOUNT WEST COMMUNITY CENTER GWCA - COMMUNITY CENTER. design recommendations
G W C C GREENMOUNT WEST COMMUNITY CENTER design recommendations GWCA - COMMUNITY CENTER PROGRAM SIDEWALK 1... ENTRANCE/EXIT A... MECHANICAL 2... LOBBY B... ELECTRICAL 1 3... RECEPTION C... MEN S TOILET
More informationConference-Seminar Table & chair Case Study (tiered) Swivel chairs, Continuous Counter Top
III. DESIGN 3.03 Academic Building Interior Space Square Footage Standards A. Plan academic spaces in new buildings and in the major renovation of existing buildings to conform to the following space standards:
More informationTHIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL
SECTION 15100 PART 1 GENERAL THIS IS A DESIGN GUIDE NOT A SPECIFICATION Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL HVAC SYSTEMS APPLICATIONS 1.1 SCOPE: The intent of this
More informationFraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.
Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.1) House Name Date Address Inspector(s) No. of Residents
More informationM001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More information3520 A Energy Conservation Standards
3520 A Energy Conservation Standards Regulation Original Adoption: 04/14/2009 Effective Date: 08/06/2009 Revision Dates: 08/05/2009 I. PURPOSE The purpose of this regulation is to establish the energy
More informationLIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES
LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.
More informationLaboratory Division. Product Range Cold Storage Clean Air Lyo
Laboratory Division Product Range Cold Storage Clean Air Lyo Laboratory Division Product Range Laminar Flow & Biosafety cabinets Operator, product & environment protection Microbiological safety cabinets
More informationMechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation
Mechanical Technical Report 1 Standard 62.1 Ventilation Compliance Evaluation Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department
More informationPhoto catalogue. Labor
Photo catalogue Labor Waldner Labor The consequent orientation Labor For more than 50 years Waldner have been designing, developing and manufacturing first-class laboratory furniture. Many of our developments
More informationCarthage College. Fire Incidents by Building for 2016
Carthage College The Campus Fire Safety Right to Know Act is a bill aimed at increasing fire safety awareness on college campuses. It is an amendment to the Higher Education Act of 1965, which requires
More informationL a b o r a t o r y E q u i p m e n t C a t a l o g
B y S t a t i t e c h L a b o r a t o r y E q u i p m e n t C a t a l o g Fume Cupboards & Ductless Fume Hoods Biological Safety Cabinets Laminar Flow Clean Benches PCR Cabinets Complete Laboratory Furnishing
More informationState College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationWhite Bear Lake Area Schools District 624 ENERGY GUIDELINES
White Bear Lake Area Schools District 624 ENERGY GUIDELINES Developed by: White Bear Lake Area Schools Energy Steering Committee as part of the Schools for Energy Efficiency (SEE) Program ISD 624 Energy
More informationAssembly Instructions SMH 3 Stage MSA
Assembly Instructions SMH 3 Stage MSA MSA Assembly is a 2 Person Operation Pre Assembly instructions: Find suitable level ground Layout Bases in position with directional arrows Insert Duck Board Flooring
More informationPty. Ltd. 1. Classroom Cleaning Daily Wkly Mthly Other Vacuum and mop all hard surfaces Vacuum and spot clean all carpeted areas Remove any cobwebs Cl
Pty. Ltd. CLEANING SPECIFICATION Pre-school Building Block A and Block B (New Building) Classrooms Staff Rooms Science Labs Library & Multi-Purpose Hall All Toilets and Amenities Front Entry and Foyer
More informationBiological Safety Cabinet
Biological Safety Cabinet (Class I & Class II Type A2/B2, Class III) Senova Labtech (Shanghai) Co., Ltd. Class I Biological Safety Cabinet The Class I biological safety cabinet is an open-front negative
More informationEAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT
EAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT March 2017 Fire Risk Assessment Contents Introduction Page 2 Fire hazards Page 2 People at risk Page 3 Evaluate, remove, reduce, protect from risk
More informationSUNY Oswego Campus-wide Lactation Room Implementation Study. REVISED November 29, 2016
SUNY Oswego Campus-wide Lactation Room Implementation Study REVISED November 29, 2016 Dwyer Architectural 313 East Willow Street Suite 107 Syracuse, NY 13203 (315) 473-1800 Watts Architecture & Engineering
More informationWays to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save
Ways to Save Energy efficiency tips to help you lower your monthly power bill 1 Ways To Save 2 Ways To Save Money Saving Advice Jackson EMC is a good resource to use in your energy planning. We can show
More informationLaboratory Design, Accommodation & Environment. Presenter : Sonam Bansal Head -Nestlé Quality Assurance Centre Nestlé India Limited
Laboratory Design, Accommodation & Environment Presenter : Sonam Bansal Head -Nestlé Quality Assurance Centre Nestlé India Limited Table of Contents 1: Getting Started: Overall Safety Remarks 2: Zoning
More informationPraise to God and thanks to everyone that has participated in Moving Forward in Faith!
MFIF Forum Purpose Thank Everyone For Their Participation In The Campaign Status Of Activities To Date Plans For The Future Obtain Feedback From The Parish Praise to God and thanks to everyone that has
More informationAccess Statement Shoreline Apartment 3 Church Street Craster NE66 3HT
Pre-Arrival Give the name and distance of the nearest railway station. Alnmouth - 17 miles / Newcastle -35 miles / Berwick 32 miles State whether an accessible taxi service is available. Nearest taxi firms
More informationVP, Facilities and Construction Management
Title: Biological Safety Cabinets Procedure Effective Date: November 2005 Revision Date: February 24, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental
More informationBIOLOGICAL SAFETY CABINET
BIOLOGICAL SAFETY CABINET MIT-EHS Biosafety Program - 2014 Learning objectives Learn about different types of laboratory ventilation equipment and their uses in biological research Learn about best practices
More informationINCREASE YOUR LAB EFFICIENCY
INCREASE YOUR LAB EFFICIENCY Mars Class 2 Dual Filters Microbiological Safety Cabinets Scandinavian by Design The Mars Class 2 cabinet is the ideal choice for your laboratory whenever operator, environmental
More informationCork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award
Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award Instructions Answer FIVE questions, All questions carry equal marks. (NFQ Level 6) Autumn 2006 Building
More informationFood Service Plan Review Information
Food Service Plan Review Information New or remodeled food preparation facilities, and those changing ownership, must undergo a plan review process prior to a health permit being issued. The purpose of
More informationLab and Shop Orientation
Lab and Shop Orientation The lab is located at SNARL, 1016 Mount Morrison Road. The main lab area consists of 4 individual lab spaces (1002a-d). Smaller, individual labs (1101-1103) are available as well
More informationTERRACE VIEW APARTMENTS
TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 2 x 1.5 TH Phase 4 Unit Number 17 Units Total 1) 29B 2) 30H 3) 31E 4) 31F 5) 32F 6) 32H 7) 33A 8) 33D
More informationSCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003
SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 No. Discipline Sent to Name Item Date Noted Date Resolved How item was resolved SCO # 1Punch listed items were noted below on
More informationHydroMassage Electrical / Installation Preparation Requirements
HydroMassage Electrical / Installation Preparation Requirements Electrical Requirements Series 340 / 350 Models (*Important- the items below are required for EACH HydroMassage unit). Requires a single-phase,
More informationINCREASE YOUR LAB EFFICIENCY
INCREASE YOUR LAB EFFICIENCY Fortuna Clean Bench Vertical Laminar Flow Clean Air Cabinets Scandinavian by Design The Fortuna range of cabinets offers the ultimate in product protection, operator comfort
More information<< COMPANY LETTERHEAD >>
Healthcare Facilities Accreditation Program Attn: Engineering Department 142 E. Ontario Street Chicago, IL 60611 > < Date > RE: Request for Code Equivalency ABC General Hospital,
More informationAccess Statement for Craster Rocks
Coastal Retreats want to make everyone s stay as enjoyable as possible, and are committed to providing suitable access for all our guests, whatever their individual needs. We aim to accurately describe
More informationEXISTING CONDITIONS SUMMARY
SITE Fire alarm system does meet current requirements Accessible path of travel lacking throughout campus Announcer s booth at Football Field booth not ADA compliant Covered and non covered outdoor eating
More informationTECHNIQUES IN MOLECULAR BIOLOGY BASIC TECHNIQUES: PIPETING AND STERILE CULTURE
Mastery of micropipetting and sterile technique is essential for reliable success in molecular biology. Take these exercises and our discussions about pipetting seriously. Micropipettors A micropipettor*
More informationHETTICH BENELUX THERMOMIXERS, BLOCK THERMOSTATS
THERMOMIXERS, Quality; long lifespan. Extensive range of interchangeable aluminium blocks. Specific temperature calibration. Orbital or linear mixing movement. Multilingual. Custom made blocks with a variable
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.
More informationSafe Use of a Class II Biological Safety Cabinet
UBC Biosafety Committee 102-6190 Agronomy Rd. Vancouver BC, V6T 1Z3 Standard Operating Procedure General Use IBC-SOP-002 Effective date: November 20, 2013. Review date: April 30, 2014. Supersedes: N/A.
More information4. Plumbing fixtures. a) The plumbing fixtures are from the original building. They are appear old and not to comply with ADA requirements.
From: Jian Zhang Sheet: 1 of 8 Date of Visit: 12/7/10 Coach House: Plumbing Systems b) All original building storm piping shows significant signs of aging. b) All original building sanitary piping shows
More informationAnimal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI
Animal Tissue Culture SQG 3242 Equipment and Lab design Dr. SITI PAULIENA MOHD BOHARI Sign Symbol? Biohazard sign Means? Hazardous For labeling the biological materials that carry a significant health
More informationFire Risk Assessment
Fire Risk Assessment Address of Property Assessed: Person Undertaking the Assessment - Name: Position: Date of Assessment: The Lodge, 1 Hunt Street, Swindon, Wiltshire SN1 3HW Anna-Marie Dutton Manager
More informationStandard Operating Procedure M.I.C.E.
Introduction racks are connected to the facility s exhaust system with flexible air hoses. All Animal Care Systems racks use the same type of hose, which connects using special thimble connectors. The
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More information+91-8071678468 Precious Techno Engineering http://www.precioustechno.in/ We "Precious Techno Engineering" are reckoned organization in the market, highly indulged in manufacturing and trading a broad array
More informationPremium Laboratory Equipment. Bio Tools
Premium Laboratory Equipment Bio Tools Sterilizers Laboratory Sterilizers for Infection Control Manual Manually operated models that feature analog controls and gauges for simple operation. Electronic
More informationTERRACE VIEW APARTMENTS
TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 3A x 1.5 Phase 5-8 Unit Number 4 Units Total 1) 6600F 2) 6800K 3) 7600G 4) 7900H SCOPE OF WORK A-108-E
More informationRieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:
Vertrieb durch: Rieger Industrievertretungen GmbH Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da: E-Mail: office@rieger-iv.at Telefon: +43(1) 728 00 52 Fax:
More informationENVAIR lab CO2 Incubator
ENVAIR lab CO2 Incubator Laboratory Incubator Air-jacketed CO2 Incubator Introduction C02 Incubators are widely used in scientific research to grow and maintain cell cultures. A ENVAIR lab CO2 Incubator
More informationAPARTMENTS CRIKVENICA DRAMALJ, VUKOVARSKA 105
APARTMENTS CRIKVENICA DRAMALJ, VUKOVARSKA 105 Investor: Franjo i Zdenka Židov, Samobor +385 (0) 91 2220 250 mariozidov@gmail.com Page 1 Investor: Franjo i Zdenka Židov, Samobor +385 (0) 91 2220 250 mariozidov@gmail.com
More informationTERRACE VIEW APARTMENTS
TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 4 x 2.5 Phase 5-8 Unit Number 1 Unit Total 1) 7400B SCOPE OF WORK A-112-C 4 Bedroom 2 Bath 2 Half
More information12 th Pacific Science Inter Congress HEALTH AND SAFETY INFORMATION BOOKLET FOR PARTICIPANTS
12 th Pacific Science Inter Congress HEALTH AND SAFETY INFORMATION BOOKLET FOR PARTICIPANTS 1 Occupational Health and Safety Each delegate has a duty of care to fellow delegates by ensuring that they shall,
More informationEstimate Form for Kitchen Design and Installation
Form for Kitchen Design and Installation Name: Home Address: City: State: Phone (Home): Phone (Office): Phone (Office): Phone (Office): Phone (Jobsite): Jobsite Address: City: State: By: Hereafter called
More informationUniversity of Pittsburgh. Scaife Hall 3550 Terrace Street Occupant Information
University of Pittsburgh Scaife Hall 3550 Terrace Street Occupant Information This information is for occupants of Scaife Hall, and pertains to University of Pittsburgh activities. This information does
More informationRoyal Wolfson Foundation Laboratory Refurbishment Grants Scheme Final Report: University of Glasgow, Prof Lee Cronin
Royal Wolfson Foundation Laboratory Refurbishment Grants Scheme Final Report: University of Glasgow, Prof Lee Cronin Background In January 2011, the Royal Society Wolfson Laboratory Refurbishment Scheme
More informationKNX PHASE I 43 PHASE II 45 PHASE III 46 PHASE IV
CONTENTS Chapter I Designing a KNX installation... 3 Scope of information required to create a design... 3 Template: customer requirement questionnaire for the KNX system... 4 What should a design contain?...
More informationPLATTEVILLE MIDDLE SCHOOL
Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle
More informationSPACE TYPE: JUDICIAL CHAMBER
SPACE TYPE: JUDICIAL CHAMBER Construction Criteria The unit costs for Judicial Chamber space types are based on the construction quality and design features in the following table. This information has
More informationWILLIAM & MARY CUSTODIAL TASK & FREQUENCY LIST. PUBLIC SPACE: ENTRANCES, LOBBIES, AND CORRIDORS Daily Weekly Monthly Quarterly Yearly
WILLIAM & MARY CUSTODIAL TASK & FREQUENCY LIST PUBLIC SPACE: ENTRANCES, LOBBIES, AND CORRIDORS Daily Weekly Monthly Quarterly Yearly Collect & properly dispose of recycling as needed Dust, or wipe all
More informationPART III. Laboratory equipment
PART III Laboratory equipment 10. Biological safety cabinets Biological safety cabinets (BSCs) are designed to protect the operator, the laboratory environment and work materials from exposure to infectious
More informationDietary Crises Questions and Answers
Dietary Crises Questions and Answers Problem #1: The power goes out and your freezer and refrigerator are not on the emergency generator. Help will not arrive for a day or two. Solution #1: FREEZER: Keep
More informationINCREASE YOUR LAB EFFICIENCY
INCREASE YOUR LAB EFFICIENCY Mars Pro Class 2 Ultra-Safe Triple Filters Microbiological Safety Cabinets Scandinavian by Design Mars Pro, the ideal choice for your laboratory, wherever personal, environment,
More informationAccess Statement for Mr & Mrs Smith s
Coastal Retreats want to make everyone s stay as enjoyable as possible, and are committed to providing suitable access for all our guests, whatever their individual needs. We aim to accurately describe
More informationUNC Chapel Hill Design Requirements for Level 3 Biological Safety Laboratories & Animals
UNC Chapel Hill Design Requirements for Level 3 Biological Safety Laboratories & nimals I General Criteria The purpose of this Guideline is to establish the criteria for Design and Construction of Level
More informationAlabama Department of Public Health. Retail Food Sales
Alabama Department of Public Health Retail Food Sales } Retail product is sold to the final consumer. } Processing product is sold to a business for further sale wholesale. } Combination Establishments:
More informationBeaufort County Community College. Maintenance and House Keeping Plan
Beaufort County Community College Maintenance and House Keeping Plan Summary: The College s facility management is handled by the Maintenance Department. The Director of Plant and Maintenance Operations
More informationGuidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai
Guidelines for Ideal Layout for an Operating Theater Complex Dr.R.D.Ravindran Aravind Eye Hospital Madurai Patient Flow 1. WARD 4. RECOVERY ROOM 2. BLOCK ROOM 3. THEATRE Transfer area This is an area,
More informationWe change the climate and Air pressure COMPLETE CLEAN ROOM SOLUTIONS IN SINGLE WINDOW SERVICE PROVIDER.
AIR CARE PROJECTS We change the climate and Air pressure COMPLETE CLEAN ROOM SOLUTIONS IN SINGLE WINDOW SERVICE PROVIDER. Group of Companies SSV SYSTEMS Air Care Projects We Started in 1999 has two divisions
More informationFIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES
FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document
More informationThe Wendy House McFarlands Down St Mary's. Type: Type: House. St. Marys. Location: 550,000. Price: Bedrooms:
Type: Type: Location: House St. Marys A spacious modern family house, situated in an elevated position adjoining open countryside, with far-reaching sea and island views. This spacious modern home was
More informationOakdale Primary School Expansion Project Appendix A - MEP Schedule of Works
Oakdale Primary School Expansion Project Appendix A - MEP Schedule of Works HBS-SH-MEP-801 May 2017 For Peterborough City Council ver. author date checked comment P1 KA 19-05-17 TC TENDER ISSUE 1 1. Mechanical
More informationCOOLING. 4/05/04 Std.
4/05/04 Std. 1.0 GENERAL: The U. S. Laser cooling system is a closed loop primary, open loop secondary, water-to-water heat exchanger. Temperature regulated distilled deionized water is circulated on the
More informationAccessibility Statement
Last updated: 1 st November 2016 Introduction Accessibility Statement Ballagreyney was a working farm up until the 1950 s, the cottages are nestled in four acres of garden and the surrounding hills and
More informationAccess Statement For Bluebell Cottage, Whittingham
Access Statement For Bluebell Cottage, Whittingham Introduction Bluebell Cottage is a stone built Victorian cottage attached to The Grange which stands within 4 acres of private grounds. The cottage is
More informationAll Saints' & St John's Church Centre SAINT GILBERT OF SEMPRINGHAM CHURCH SCHOOL CHARITY Reg no:
1. Introduction All Saints and St John s Centre FIRE RISK ASSESSMENT January 2018 1.1 The Regulatory Reform (Fire Safety) Order 2005, which came into force on 1st October 2006, replaces most fire safety
More informationBSES IEQ Walkthrough Summary Spring Room Observations (Responses)
01A. ODOR: Unusual or offensive 55 01B. TEMPERATURE: Uncomfortable Kitchen Bathroom does not smell clean Kitchen was warm but it had not yet been opened for the day. in room, dirty lunch boxes 45 Need
More informationTERRACE VIEW APARTMENTS
TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 1x1.5 TH Phase 4 Unit Number 14 Units Total 1) 24B 2) 26B 3) 30F 4) 31B 5) 32B 6) 33B 7) 36B 8) 36H
More informationFIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY
FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1
More informationFor Sale - 46, Brankinstown Road, Aghalee, Craigavon, BT67 0DF
Tel: 03303309439 sales@kingston-berkeley.com www.kingston-berkeley.com For Sale - 46, Brankinstown Road, Aghalee, Craigavon, BT67 0DF Offers Over 235,000 Features Finished to an impressive standard throughout
More informationThe University of Queensland Green Labs Program
Green Labs Assessment Green Labs Rep: Lab name: School / Section: of Staff / Students in Lab: Date of assessment: Green Labs Assessor: Lab name of GL Assessor: School / Section of GL Assessor: The Green
More informationCDLC Rehab. Karen E. Conway Conway Creations. As inspired by your logo, hues of blues and yellows enliven durable commercial flooring and hardworking
CDLC Rehab Karen E. Conway Conway Creations As inspired by your logo, hues of blues and yellows enliven durable commercial flooring and hardworking surfaces. A cohesive mix of light wood tones and steel
More information2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16
1. General: This summary is offered as a supplement to the 2015 Building Condition Survey being filed with SED on behalf of the District. All cost estimates are preliminary, and should be re-evaluated
More informationLSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)
LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC) Policy: Maintenance of Laboratory Equipment Adopted April 26, 2012 Properly functioning laboratory equipment is a critical
More informationCOOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER. 10,000 BTU to 60,000 BTU Capacities L IS T E D ISO 9001, ISO 14001
COOLING SOLUTIONS A Division Of CAG Purification Inc. SPOT COOLER 10,000 BTU to,000 BTU Capacities Standard year warranty 1 Extra year for compressor CM C US L IS T E D ISO 9001, ISO 14001 Portable Spot
More informationRental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN
Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN 55021 www.faribault.org (507) 333-0359 Property Address: Number of Units Building Type Name
More information