ROOM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT AQ09A5(6)MA UQ09A5(6)MA AQ12A5(6)MC UQ12A5(6)MC SERVICE

Size: px
Start display at page:

Download "ROOM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT AQ09A5(6)MA UQ09A5(6)MA AQ12A5(6)MC UQ12A5(6)MC SERVICE"

Transcription

1 ROOM AIR CONDITIONER INDOOR UNIT AQ09A5(6)MA AQ2A5(6)MC OUTDOOR UNIT UQ09A5(6)MA UQ2A5(6)MC SERVICE Manual AIR CONDITIONER CONTENTS. Installation 2. Disassembly and Reassembly. Troubleshooting 4. Exploded Views and Parts List 5. Refrigerating Cycle Block Diagrams 6. Wiring Diagrams 7. Schematic Diagrams E DB80086A(2)

2 . Installation Refrigerant Refill Procedure Refill an airconditioner with refrigerant when refrigerant has been leaked at installing or using. Purge air(for new installation only). 2. Turn the way valve clockwise to close, connect the pressure gauge(low pressure side) to the service valve, and open the way valve again. Suspension hook. Connect the tank to refill with Refrigerant 4. Set the unit to cool operation mode. 5. Check the pressure indicated by the pressure gauge(low pressure side). * Standard pressure is should be 64~78psi in a regular, high operation mode. Compound gauge For mounting other and of hose when not in use High pressure gauge Hand wheel Finger tight fittings Connected to high pressure side Charging line 6. Open the refrigerant tank and fill with refrigerant until the rated pressure is reached. * It is recommended not to pour the refrigerant in too quickly, but gradually while operating a pressure valve. R22 7. Stop operation of the air conditioner. 8. Close the way valve, disconnect the pressure gauge, and open the way valve again. 9. Close the cap of each valve.

3 2 Pump down Procedure Pump down' shall be carried out when an evaporator is replaced or when the unit is relocated in another area.. Remove the caps from the 2way valve and the way valve. 2. Turn the way valve clockwise to close and connect a pressure gauge(low pressure side) to the service valve, and open the way valve again.. Set the unit to cool operation mode. (Check if the compressor is operating.) 2Way Valve 4. Turn the 2way valve clockwise to close. 5. When the pressure gauge indicates "0" turn the way valve clockwise to close. Way Valve 6. Stop operation of the air conditioner. 7. Close the cap of each valve. Relocation of the air conditioner Refer to this procedure when the unit is relocated.. Carry out the pump down procedure (refer to the details of 'pump down'). 2. Remove the power cable.. Disconnect the assembly cable from the indoor and outdoor units. 4. Remove the flare nut connecting the indoor unit and the pipe. At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. 5. Disconnect the pipe connected to the outdoor unit. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. 6. Make sure you do not bend the connection pipes in the middle and store together with the cables. 7. Move the indoor and outdoor units to a new locatioon. 8. Remove the mounting plate for the indoor unit and move it to a new location. 2

4 2. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 2 Indoor Unit No Parts Procedure Remark Front Grille ) Stop the air conditioner operation and block the main power. 2) Separate tape of front panel upper. ) Contract the second finger to the left, and right handle and pull to open the inlet grille. 4) Take the left and right filter out. *Taking off the deodorizing filter. 5) Loosen one of the right fixing screw and separate the terminal cover. 6) Loosen three fixing screws of front grille. 7) Pull the upper left and right of discharge softly for the outside cover to be pulled out. 8) Pull softly the lower part of discharge and push it up. Caution; Assemble the front panel and fix the hooks of left and right.

5 No Parts Procedure Remark 2 Electrical Parts (Main PCB) Ass y Tray Drain. ) Do above 2) Take all the connector of PCB upper side out. (Inclusion Power cord) ) Separate the outdoor unit connection wire from the terminal block. 4) If pulling the Main PCB up. it will be taken out. ) Do, 2, above Separate the drain hose from the extension drain hose. 2) Pull tray drain out from the back body. 4 Heat Exchanger ) Do and 2,, above 2) Loosen two fixing earth screws of right side. ) Separate the connection pipe. 4) Separate the holder pipe at the rearside. 5) Loosen the three fixing screws of right and left side. 6) Lifting the heat exchanger up a little to push the up side for separation from the indoor unit. 5 Fan Motor and Cross Fan ) Do 2 4, above. 2) Loosen the fixing two screws and separate the motor holder. ) Loosen the fixing screw of fan motor. (By use of M wrench) 4) Separate the fan motor from the fan. 5) Separate the fan from the left holder bearing. 4

6 22 Outdoor Unit UQ09A5(6)MA No Parts Procedure Remark Common Work ) Loosen the fixing two screws and separate the cover Eparts. 2) Separate the connection wire from the terminal block. ) Loosen five fixing screws and separate the cabi Upper. 4) Loosen two fixing screws of Ass'y Epart. 5) Loosen nine fixing screws and separate the cabi side. 2 Fan and Motor ) Do, above. 2) Loosen four screws and seperaate Guard Fan from front cabinet 5

7 No Parts Procedure Remark 2) Remove the nut flange (Turn to the right to remove, as it is a left hand screw) ) Separate the fan. 4) Loosen four fixing screws to separate the motor. Heat Exchanger ) Do, 2 above. 2) Loosen two fixing screws of left and right side. ) Disassemble the inlet and outlet pipe by welding. 4) Separate the heat exchanger. 4 Compressor ) Do, above. 2) Loosen the nut on the terminal cover and open the terminal cover. ) Disassemble the inlet and outlet pipe of compressor by welding. 4) Disassemble the inlet and outlet pipe of condenser by welding 5) Loosen the three bolts of the lower part. 6) separate the compressor. 6

8 UQ2A5(6)MC No Parts Procedure Remark Common Work ) Loosen the fixing screw and separate the HandleCabi RH. 2) Separate the connection wire from the terminal block. ) Loosen 6 fixing screws and separate the upper cabinet. 4) Loosen the fixing screw of Ass'y Epart. 5) Loosen 5 fixing screws and separate the side cabinet. 7

9 No Parts Procedure Remark 2 FanMotor ) Loosen 4 fixing screw of the GuardFan. 2) Remove the nut flange (Turn to the right to remove, as it is a left hand screw) ) Separate the fan. 4) Loosen four fixing screws to separate the motor. 8

10 . Troubleshooting Items to be checked first ) The input voltage should be rating voltage ±0% range. The airconditioner may not operate properly if the voltage is out of this range. 2) Is the link cable linking the indoor unit and the outdoor unit linked properly? The indoor unit and the outdoor unit shall be linked by 5 cables. Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables. Otherwise the airconditioner may not operate properly. ) When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the airconditioner. Operation of air conditioner The STD operation indication LED blinks when a power plug of the indoor unit is plugged in for the first time. 2 In a COOL operation mode, the compressor does not operate at a room temperature higher than the setting temperature that the INDOOR FAN should operate. In a HEAT operation mode, the compressor does not operate at a room temperature lower than the setting temperature that indoor fan should operate. Fan speed setting is not allowed in AUTO or DRY mode. 4 Compressor stops operation intermittently in DRY mode. 5 Compressor of the outdoor unit is operating although it is turned off in a HEAT mode. 6 Timer LED only of the indoor unit lights up and the air conditioner does not operate. 7 The compressor and indoor fan stop intermittently in HEAT mode. 8 Indoor fan and outdoor fan stop operation intermittently in a HEAT mode. 9 The compressor stops intermittently in a COOL mode or DRY mode, and fan speed of the indoor unit decreases. Explanation It indicates power is on. The LED stops blinking if the operation ON/OFF button on the remote control unit is pushed. In happens after a delay of minutes when the compressor is reoperated. The same phenomenon occurs when a power is on. As a phenomenon that the compressor is reoperated after a delay of minutes, the indoor fan is adjusted automatically with reference to a temperature of the air blew The speed of the indoor fan is set to LL in DRY mode. Fan speed is 5 steps is selected automatically in AUTO mode. Compressor operation is controlled automatically in DRY mode depending on the room temperature and humidity. When the unit is turned off while deice is activated, the compressor continues operation for up to 9 minutes (maximum) until the deice is completed. Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled. The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in a HEAT mode. The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heater operation The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature. 4) Indoor unit observes operation condition of the air conditioner, and displays self diagnosis details on the display panel. Display STD LED blinking (Hz) 2 TIMER LED blinking (Hz) STD and TIMER LED blinking (Hz) 4 NATURE LED blinking (Hz) Self Diagnosis Restore from power failure (input initial power) Indoor unit Room sensor Error (open or short) Indoor unit heat exchanger temperature sensor Error (open or short) Indoor fan malfunctioning (for spead is Below 450rpm) 9

11 2 Fault Diagnosis by Symptom 2 No Power(completely dead)initial diagnosis ) Checklist : () Is input voltage normal? (2) Is AC power linked correctly? () Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC5.5VDC) 2) Troubleshooting procedure Remove power cord and plug in again in approx. 5 seconds Replace PCB display Is DC voltage of PCB display normal? Is rating voltage ±0% range applied to the primary side(~,~) of the BD7 Check linkage between power cord and terminal tap Check fuse Is 25VDC appear in the secondary side (+, ) of BD7 Is operation lamp blinking? Does operation start when ON/OFF button on the remote controller unit pushed? Is transmission display of the remote controller unit blinking? Is "beep"sound heard from the main unit? Is DC voltage of the PCB module normal? Are voltages of #8 (compressor), #7(4 way valve) and #6 (outdoor fan) of the micom normal? 5VDC Is voltage of #60 (indoor fan) of the micom normal? DC5V 0ms Normal Refer to remote control unit fault diagnosis Replace PCB module. Are voltages at RY7(Compressor) normal? DC2V Is voltage at SS7(indoor fan) Replace SMPS PARTS Is voltage at #50 terminal of the Micom normal? 0VDC Is voltage at #8 terminal of the Micom normal? 5VDC Is voltage at #52 terminal of the micom normal? Check connections compressor and indoor fan. Is output voltage of ICO2 normal? Replace RY7 and SS7 Replace resonator (X0) Is operation normal? 0ms Are voltage at #48 and #49 of the micom normal? Replace micom 250ns Check PCB pattern. Replace main PCB. Is voltage output terminal of TLP80(PC02) normal? OK Replace ICO2 Replace TLP80(pc02) OK 0

12 22 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis) ) Checklist : () Is the indoor unit fan motor properly connected with the connector (CN72)? (2) Is the AC voltage correct? () Is HALL IC in indoor fan motor properly connected with the connector (CN42)? (4) Is the running capacitor (CR7) properly connected with PCB board? 2) Troubleshooting procedure After unplugging out the power cord should be reconnected within five seconds. Does the STD lamp(green) blink? Check as in the procedure power parts Refer tp page 52. Does the Solid State Relay(SS7) work properly? Microcomputer is out of order. + Test rod location Normal Voltage SS7 SS7 2V Is the supply voltage of the fan motor sufficient? PCB is out of order. PCB should be replaced. PCB CN72 Test rod location Condition Normal voltage pin # and #5 Fan operate about AC 80V MFC is out of order Replace MFC Fan motor is out of order. Fan motor should be replaced.

13 2 When the Outdoor Unit Does Not Operate. (Initial Diagnosis) ) Checklist : () Is input voltage normal? (2) Is the set temperature of the remote control higher than room temperature in COOL mode? () Is the POWER IN connector (CN7) linked correctly? (4) Is the outdoor unit properly connected with the TERMINAL BLOCK connector((n), )? 2) Troubleshooting procedure After unplugging out the power cord should be reconnected within five seconds. Does the STD lamp blink Check as in the procedure "No Power parts" Refer to page 52. Does the timer lamp blink during operation? Room temperature sensor is out of order 2 PCB should be checked. Is the power relay RY7 operated by adjusting the room temperature? Microcomputer is out of order. Test rod location Normal + Condition Voltage IC4 Pin No.62 GND RY7 ON DC 4.8V PCB should be checked. Is rating voltage ±0% range applied relay between Terminal block (N) and No. Power relay is out of order Power relay should be replaced. 2 Outdoor unit is out of order. Is the room sensor normal register? 0 C 20 C 0 C 7.96k Ω 2.09k Ω 8.k Ω 2

14 24 When the UP/DOWN Louver Motor Does Not Operate. (Initial Diagnosis) ) Checklist : () Is input voltage normal? (2) Is the UP/DOWN louver motor properly connected with the connector (CN6)? 2) Troubleshooting procedure Remove power cord and plug in again in approx. 5 seconds. Is STD lamp blinking? Does operation start when swing button of the remote control unit pushed? Y N Y Check as in the procedure "No Power parts". Refer to page 52. Normal Voltage at pin ##4 of micom (ICO4) change?(squarewave) N N Micom (IC04) is faulty. Volatge at pin # ~ #6 of IC06 (KID6500) change?(squarewave) UP/DOWN louver motor is faulty. Y Y N Driver IC06 (KID6500) is faulty. 25 In the mode, When there is no warm air current. Check this first; () Is the set temperature of Remote Control lower than room temperature in Heat mode? (2) Is the Indoor PCB properly connected with the CN7 connector? After training on, the heating operation should start in five minutes. Is the number #8 of Micom (IC04) DC 5.0 V? Is the number checking # of IC06 (KID6500) LOW? Is the voltage between CN7 # and CN7 #5 rating voltage ±0% range Normal Abnormal Micom Abnormal IC06 Abnormal RY7 Abnormal 4way valve of Outdoor Unit. or connecting Cable 4 way valve should be replaced or connecting Cable Check. PCB should be replaced.

15 26 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis) ) Troubleshooting procedure Remove power cord and plug in again approx. 5 Seconds Is operation lamp blinking? sound heard from the indoor unit when ON/OFF button on the remote control unit pushed? Y N Y Check as in the procedure Power parts. Refer to page 52. Normal N Voltage of battery less than 2.5V (Remote Control Unit)? N LCD display status of REMOCON normal? Y Y N Replace battery. LCD is faulty. Transmission display lamp ( ) blinking when ON/OFF button on the remote control unit pushed? N Replace button. Y Voltage at PIN #0 of Remocon Micom change? Y Voltage at collecter of Q60 or Q602 change? Y N N Micom is faulty. Q60(C475Y) or Q602(C62Y) is faulty. IR LED(CLL5EU) is faulty. Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)? Y Micom (IC04) is faulty. N Receiver module is faulty. 4

16 MEMO 5

17 4. Exploded Views and Parts List 4 Indoor Unit

18 Parts List No. CODE Description AQ2A5(6)MC Q TY AQ09A5(6)MA REMARK DB A DB600064A DB74000A DB600067A DB92000L DB670005A DB670002A DB60008A DB E DB60200A DB0007A DB00072A DB200020A DB900255G DB900255H DB900267A DB900267D DB A DB650000A DB900268E DB20007A DB90047A DB A DB60062A DB60065A DB700006A DB B DB940008A DB A DB660028A DB660028B DB600082A DB95208A DB029A DB64025A DB676000A DB980494A DB A DB944000A DB90025L DB70004A DB600226A GRILLE AIR INLET GUARDAIR FILTER FILTER CLEANER ASS Y COVER TEMINAL ASS Y PANEL SPACER EVAP LOW SPACER EVAP UP COVER U BEND ASS Y FAN CROSS(SF) BOLT SPECIAL MOTOR FAN IN THERMISTOR WIRE ASS Y ASS Y CONTROL IN ASS Y PCB MAIN IC EPROM IC PWM CONTROLLER RELAY MINIATURE SSR IC MCU TERMINAL BLOCK ASS Y ASS Y PCB DISPLAY C CERAMIC,MLCAXIAL MODULE REMOCON CONNECT WIRE PCB ASS Y BACK BODY(RIGHT SIDE) HOLDER MOTOR HOLDER PIPE PLATE HANGER ASS Y TRAY DRAIN(RIGHT SIDE) ASS Y DRAIN HOSE BLADE H BLADE V,A BLADE V,B SCREEN SAFETY WIRE ASS Y MOTOR STEPPING MOTOR STEPPING; GSP 24RW HOLDER SENSOR SPRING SENSOR EVAPORATOR ASS Y EVAPORATOR ASS Y ASS Y BEARING ASS Y REMOCON PLATEKCKOUT COVERTERMINAL BLOCK

19 42 Outdoor Unit UQ09A5(6)MA

20 Parts List No. CODE Description Specitication DB600086B GUARDFAN HSWR, IP2, 5&, SC9007T, NEW AP/J 70FAN Q TY UQ09A5(6)MA 2 DB600004A NUTFLALNGE 2C, M6, SM20C, NTR DB670006A FANPROPELLER AS+G/F20%, PI 75, BLK 4 DB0058G MOTORFAN OUT AMASS020ZREA, FAN OUT, 5V/60Hz 5 DB A ASS Y FRAME (PAINT) SC9007T 6 DB A ASS Y PARTITION ASS Y 620mm COND 7 DB B ASS Y CABIUPPER ASS Y 8 DB900424A ASS Y CONTROL OUT ASS Y COIL (COMP) 45µF, 70VAC COIL (MOTOR) 4.0µF, 450VAC 8 DB0042A ASS Y LEAD WIRE ASSY 84 DB B SOLEID ASS Y RANCO, LB DB A TERMINAL BLOCK 5P, N, L,, 2, 9 DB720045A CLOTHCOMP T8, 425, 225, 44F COMP 0 44B092HWEL ROTARY COMP Ph, 5V, 60Hz DB520066E PROTECTOR O/L MRA DB70004B GROMMETISOLATOR SILICON DB60008A NUTFLANGE PI0.8, M5, SM20C 4 DB620002A GASKET EPDM, TO.8 5 DB6065D COVERTERMINAL PBT 6 DB600028A NUTWASHER HEX, 2C, M8, ZPC 7 DB A ASS Y TUBE CAPILLARY ID.5 x 00+/4 7 DB B VALVESERVICE /4INCH 8 DB D ASS Y VALVE 4WAY VK00B+/8 8 DB62008A TUBE4WAY VALVE BRASS, /8INCH, T.0, RANCO 82 DB624007B VALVESERVICE C77BD, 42L/H, /8, 0Kg/cm2G 9 DB A ASS Y COND.5DFIN, COATTING 620mm 20 DB64607D CABINETSIDE SECCP, T 0.8, AP/J 2 DB A HANDLECABI LF ABS 22 DB6044C COVERE, PARTS ASS Y SC9007R 9

21 UQ2A5(6)MC

22 Parts List (OUTDOOR UNIT) No. CODE Description Specitication DB60007A GUARD FAN HSER Q TY UQ2A5(6)MC 2 DB600004A NUT FLANGE 2C SM20C M6 NTR DB675006A PROPELLERFAN AS+G/F, Ø405 4 DB0058C MOTOR FAN OUT ASSO2OWTVA 5 DB A ASS Y FRAME(PAINT) ASS Y 6 DB A ASS Y PARTITION ASS Y 7 DB B CABINET UPPER SECCP 8 DB900424E ASS Y CONTROL OUT ASS Y CAPACITOR COMP 25µF 70VAC CAPACITOR MOTOR.5µF 450VAC 8 DB A TERMINAL BLOCK 5P, N, L,, 2, 84 DB90042A ASS Y LEAD WIRE ASS Y 85 DB472000L O L P MRA DB A O L P SPRING STS04 87 DB B ASS Y SOLEIDE LB800 RANCO 88 DB200007A THERMOSTAT 250V, 7A 9 DB D CLOTH COMP BOTTOM FELT 0 DB A ASS Y 4WAY VALVE ASS Y 48A5IVEL COMPRESSOR 20820V 60Hz 2 DB70004B GROMMETISOLATOR SILICON DB600028A NUTWASHER HEX 2C MB ZPC 4 DB620002A GASKET EPDM 5 DB6065D COVER TERMINAL PBT 6 DB60008A NUTFLANGE M5, SM20C 7 DB96005A ASS YCAPILLARY ASS Y(.7 X00) 8 DB A ASS Y COND ASS Y(SF) 9 DB64006C CABINET SIDE ASS Y(BENDING) 20 DB A HANDLE CABI, RH ABS 2 DB72002A CLOTHCOMP SIDE FELT 22 DB950022A ASS YHEATER ASS Y 2

23 4 ASS Y CONTROL IN Parts List No Description Specification Remark HOLDER CONTROL ABS 2 ASS Y MAIN PCB AS09AME ASS Y TERMINAL BLOCK 4 ASS Y DISPLAY PCB AS09AME 5 CONNECTOR WIRE PCB U/D 6 BRACKET EARTH SGCCM 7 HOLDER WIRE CLAMP 8 CONNECTOR WIRE EARTH AWG#6 9 SCREW WP, TH + M4 L8, ZPC(WHT), T.C 0 SCREW PH, M L22 SCREW TH + M4 L6, ZPC(WHT), SWRCH 2 HOLDER CLAMP IN SEAL PANEL FRONT RH 4 SEAL H/CONTROL FRONT 22

24 5. Refrigerating Cycle Block Diagram INDOOR UNIT OUTDOOR UNIT Capillary tube T 2way valve Liquid side Heat exchanger (Evaporator) Cross fan Heat exchanger (Condenser) Propeller fan T2 Gas side way valve Compressor 4way valve Cooling Heating Gas leak check point Refrigerating cycle temperature and pressure STD Pressure Piping Temp.( F) Use Temp. Condition ( F) Operating Condition (psi) Indoor Outdoor WAY V/V T T2 DB WB DB WB Standard 70~74 48~5 48~ Cooling Max over load 60~64 60~ Low temp 4~9 4~ Standard 248~287 99~0 4~ Heating Max over load 00~09 40~ Deice 85~95 07~

25 6. Wiring Diagrams 6 Indoor Unit AQ09A5(6)MA AQ2A5(6)MC 24

26 62 Outdoor Unit UQ09A5(6)MA DIAGRAMOUTDOOR C : 4µF x 450VAC C2 : 45µF x 70VAC UQ2A5(6)MC DIAGRAMOUTDOOR C :.5µF x 450VAC C2 : 25µF x 70VAC 25

27 7. Schematic Diagrams 7 Indoor Unit AQ09A5(6)MA 26

28 AQ2A5(6)MC 27

29 ELECTRONICS Printed in Korea.

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4

More information

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AS18A9(0)RCF AS18A9(0)RCFD AS24A1(2)RC AS24A1(2)RCD

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AS18A9(0)RCF AS18A9(0)RCFD AS24A1(2)RC AS24A1(2)RCD AS8A9(0)RCF SM_E_5775 3/0/05 7:6 PM Page 43 SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AS8A9(0)RCF AS8A9(0)RCFD AS24A(2)RC AS24A(2)RCD Outdoor Unit US8A9(0)RCF US8A9(0)RCFD US24A(2)RC US24A(2)RCD

More information

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation ROOM AIR CONDITIONER AW079 AW089 SERVICE Manual AIR CONDITIONER CONTENTS. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting

More information

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ18A9(0)RCF AQ18A9(0)RCFD AQ24A1(2)RC AQ24A1(2)RCD

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ18A9(0)RCF AQ18A9(0)RCFD AQ24A1(2)RC AQ24A1(2)RCD SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ8A9(0)RCF AQ8A9(0)RCFD AQ24A(2)RC AQ24A(2)RCD Outdoor Unit UQ8A9(0)RCF UQ8A9(0)RCFD UQ24A(2)RC UQ24A(2)RCD E DB985778A(4) Safety Precautions The

More information

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Block Diagrams

More information

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the

More information

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ18A9(0)RCF AQ24A1(2)RC

SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ18A9(0)RCF AQ24A1(2)RC SERVICE Manual SPLIT TYPE AIR CONDITIONER Indoor Unit AQ8A9(0)RCF AQ4A()RC Outdoor Unit UQ8A9(0)RCF UQ4A()RC E DB985778A() Safety Precautions The following safety precautions must be taken when using your

More information

4. Disassembly and Reassembly

4. Disassembly and Reassembly 4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

SERVICE Manual AIR CONDITIONER INDOOR UNIT SH09AWH SH09ZWH AQ09WHWE KFR-25G/SWA SH12AWH SH12ZWH AQ12WHWE KFR-35G/SWA

SERVICE Manual AIR CONDITIONER INDOOR UNIT SH09AWH SH09ZWH AQ09WHWE KFR-25G/SWA SH12AWH SH12ZWH AQ12WHWE KFR-35G/SWA ROOM AIR CONDITIONER INDOOR UNIT SH09AWH SH09ZWH AQ09WHWE KFR5G/SWA SHAWH SHZWH AQWHWE KFR5G/SWA OUTDOOR UNIT SH09AWHX SH09ZWHX UQ09WHWE KFR5W/SWA SHAWHX SHZWHX UQWHWE KFR5W/SWA SERVICE Manual AIR CONDITIONER

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

SERVICE Manual AIR CONDITIONER AW05B05A(AW0500, AW0500A) AW05E05A(AW0510, AW1510A) AW05F05A. 1. Precautions. 2. Product Specifications

SERVICE Manual AIR CONDITIONER AW05B05A(AW0500, AW0500A) AW05E05A(AW0510, AW1510A) AW05F05A. 1. Precautions. 2. Product Specifications ROOM AIR CONDITIONER AW05B05A(AW0500, AW0500A) AW05E05A(AW050, AW50A) AW05F05A SERVICE Manual AIR CONDITIONER CONTENTS. Precautions 2. Product Specifications. Installation and Operating Instructions 4.

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

SERVICE Manual CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX. 1. Product Specifications

SERVICE Manual CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX. 1. Product Specifications CEILING TYPE AIR CONDITIONER INDOOR UNIT FH052EZA FH070EZA OUTDOOR UNIT FH052EZX FH070EZX SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Trouble Shooting 3. Block Diagrams 4. Disassembly

More information

AIR CONDITIONER. Model : 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

AIR CONDITIONER. Model : 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5. SYSTEM AIR CONDITIONER Model : INDOOR UNIT AC012MNADCH/AA AC018MNADCH/AA AC024MNADCH/AA AC030MNTDCH/AA AC036MNTDCH/AA OUTDOOR UNIT AC012KXADCH/AA AC018JXADCH/AA AC024JXADCH/AA AC030JXADCH/AA AC036JXADCH/AA

More information

Model name: AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH AJ007JNADCH AJ009JNADCH AJ012JNADCH

Model name: AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH AJ007JNADCH AJ009JNADCH AJ012JNADCH Model name: AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH AJ007JNADCH AJ009JNADCH AJ012JNADCH MULTI AIR CONDITIONER INDOOR UNIT AJ018JNADCH AJ024JNADCH AJ009JNLDCH AJ012JNLDCH AJ018JNLDCH OUTDOOR UNIT AJ020JCJ2CH

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: ASR609CL ASR612CL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. ASR609CL 387006970 ASR612CL 387006971 0.8180.250.0 05/2002 IMPORTANT! Please read

More information

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT

More information

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...

More information

FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT

More information

SPLIT-TYPE AIR CONDITIONER

SPLIT-TYPE AIR CONDITIONER SPLIT-TYPE AIR CONDITIONER INDOOR UNIT Basic : AQB09JJWC AQB12JJWC Model : AQV09JA AQV12JA Model Code : AQV09JA AQV12JA OUTDOOR UNIT AQV09JAX AQV12JAX AIR CONDITIONER THE FEATURE OF PRODUCT High Energy

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................

More information

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF94R5 CAF124R5 SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. CAF94R5 387106979 CAF124R5 387106980 0.8180.361.0 07/2005 IMPORTANT! Please read before

More information

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02 Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

CONTENTS 1. Specifications... 2. Features and Technical Explanation... 2-1. Featurs... 2-2. Neuro fuzzy Washing time optimization... 2-3. Water level Contorl... 2-4. Door Contorl... 2-5. The door can cont

More information

Multi Type Room Air Conditioner

Multi Type Room Air Conditioner Multi Type Room Air Conditioner SERVICE MANUAL INDOOR UNIT: AMNN076L/M/NQA0 AMNN096L/M/NQA0 AMNN6L/M/NRA0 AMNN86L/M/NTA0 AMNN46L/M/NTA0 AMNN096APA0 AMNN6APA0 AMNN6TEA0 AMNN86TEA0 AMNN86VBA0 OUTDOOR UNIT:

More information

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY0ELA AOY0EPBL CONTENTS SPECIFICATIONS.............................. OUTLINE AND DIMENSIONS...................... CIRCUIT DIAGRAM............................

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-04004-3 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKHP-E3 / RAS-13UAH-E3 RAS-10UKHP-E3 / RAS-10UAH-E3 RAS-07UKHP-E3 / RAS-07UAH-E3 RAS-13UKP-E3 / RAS-13UA-E3 RAS-10UKP-E3 / RAS-10UA-E3

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39

More information

Mobile Type Air Conditioner

Mobile Type Air Conditioner Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS. SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM

More information

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5. SYSTEM AIR CONDITIONER 4 WAY CASSETTE SERIES Model : INDOOR UNIT AC018JN4DCH/AA AC024JN4DCH/AA AC030JN4DCH/AA AC036JN4DCH/AA AC042JN4DCH/AA AC048JN4DCH/AA OUTDOOR UNIT AC018JXADCH/AA AC024JXADCH/AA AC030JXADCH/AA

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

REF5-BB Undercounter Blood Bank Refrigerator

REF5-BB Undercounter Blood Bank Refrigerator REF5-BB Undercounter Blood Bank Refrigerator Order parts online www.follettice.com Installation, Operation and Service Manual Following installation, please forward this manual to the appropriate operations

More information

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type ) SPLIT T YPE ROOM AIR CONDITIONER WALL MOUNTE type Models Outdoor Unit Serial No. Starting with T000001 ( Compressor Recipro type ) Indoor unit ASU18C1 ASU18R1 ASU24C1 ASU24R1 ASU30C1 Outdoor unit AOU18C1

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 Service Manual Room Air Conditioner Split Wall-Mounted Type Applies to: HSG-09CRN1 HSG-12CRN1 HSG-18CRN1 HSG-24CRN1 HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1 NOTE: Please read this first before servicing

More information

EVAPORATIVE AIR COOLER SERVICE MANUAL

EVAPORATIVE AIR COOLER SERVICE MANUAL EVAPORATIVE AIR COOLER SERVICE MANUAL CAUTION: Before servicing the unit, read the Safety Precautions in this manual. Only for authorized service. MODEL NO.: CL30XC & CHL30XC (INDOOR USE ONLY) CONTENT

More information

YC ON-OFF SERIES. Service Manual

YC ON-OFF SERIES. Service Manual YC ON-OFF SERIES Service Manual CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Model Lists... 6 3. Dimension... 7 3.1 Indoor Unit... 7 3.2 Outdoor Unit... 11 4. Refrigerant

More information

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Wall Mounted Air Conditioner SVC MANUAL(Exploded View) MODEL : AMNW07GDBL1 [LMN077HVT] AMNW09GDBL1 [LMN097HVT] AMNW12GDBL1 [LMN127HVT] AMNW15GDBL1 [LMN157HVT]

More information

Ceiling Duct Air Conditioner SVC MANUAL(Exploded View)

Ceiling Duct Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Ceiling Duct Air Conditioner SVC MANUAL(Exploded View) MODEL : LB-E4880HL CAUTION Before Servicing the unit, read the safety precautions in General SVC manual.

More information

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error www.olmo-comfort.com TROUBLESHOOTING When below list for identification of error code occurs, please turn off air conditioner and disconnect power, and then contact the qualified professionals for service.

More information

SERVICE MANUAL K LIGHT COMMERCIAL

SERVICE MANUAL K LIGHT COMMERCIAL SERVICE MANUAL 36 48 60K LIGHT COMMERCIAL Cassette indoor unit Under-ceiling indoor unit Ducted indoor unit 42QTD036DS* 42QTD048DS* 42QTD060DS* 42QZL036DS* 42QZL048DS* 42QZL060DS* 42QSM036DS* 42QSM048DS*

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

WALL MOUNTED TYPE ROOM AIR-CONDITIONER TECHNICAL MANUAL & PARTS LIST DRAFT WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S (Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SYSTEM AIR CONDITIONER

SYSTEM AIR CONDITIONER SYSTEM AIR CONDITIONER AHU SERIES Model : INDOOR UNIT AC018KNZDCH/AA AC024KNZDCH/AA AC030KNZDCH/AA AC036KNZDCH/AA AC042KNZDCH/AA AC048KNZDCH/AA AC054KNZDCH/AA OUTDOOR UNIT AC018JXADCH/AA AC024JXADCH/AA

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Mode Temp Room Air Conditioner Service and Parts Manual 0F Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power CP10 CP12 CP10 - CP12 (06/14) 93011402_04 CONTENTS 1. PREFACE 1.1 SAFETY

More information

Operating Instruction & Parts Manual Model : HSC-18PLUS/24PLUS

Operating Instruction & Parts Manual Model : HSC-18PLUS/24PLUS AIRREX AIR CONDITIONER Operating Instruction & Parts Manual Model : HSC-18PLUS/24PLUS Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain

More information

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION PART NUMBER BY CAPACITY 9/12 15 18/24 30 36/42 48 1 1 FRONT PANEL W/LOUVER 550-373 550-373 550-374 550-374 550-388

More information

Display Cases Deli Cases Service Manual

Display Cases Deli Cases Service Manual Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Display Cases Deli Cases Service Manual Please read this manual completely before attempting

More information

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT DocID: 00G00019E 2008 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Fast Track Troubleshooting Models Covered: RF266AD**/XAA French Door Refrigeration IMPORTANT SAFETY NOTICE For Technicians Only This service data sheet is intended for use by persons having electrical,

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE -(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3

More information

Commercial Upright Bottom Mount Refrigerator & Freezer Service Manual

Commercial Upright Bottom Mount Refrigerator & Freezer Service Manual Commercial Upright Bottom Mount Refrigerator & Freezer Service Manual - 1 - TABLE OF CONTENS 1. ASSEMBLY 4~15 2. PARTS 16~36 3. WIRING DIAGRAM 37~39 4. PART DETAILS 40~44 5. MAIN COMPONENTS 45~61 6. ELECTRONIC

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AE22AH 387031006 AE28AH 387031007 AE38AH 387031008

More information

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Models Covered: RF266AA**/XAA RF266AB**/XAA RF266**/XAA French Door Refrigeration NOTICE: RF266AA & AB** 01/09 Parts Change: Refer to bulletin. All Water Tank Parts Forced Mode: Press the Pwr Freeze Fridge

More information

AIR CONDITIONER OUTDOOR UNIT INDOOR UNIT. 1. Precautions

AIR CONDITIONER OUTDOOR UNIT INDOOR UNIT. 1. Precautions MULTI AIR CONDITIONER INDOOR UNIT AJ009JNNDCH/AA AJ012JNNDCH/AA AJ018JNNDCH/AA AJ007JNADCH/AA AJ009JNADCH/AA AJ012JNADCH/AA AJ018JNADCH/AA AJ024JNADCH/AA AJ009JNLDCH/AA AJ012JNLDCH/AA AJ018JNLDCH/AA AJ009NBNDCH/AA

More information

SERVICE MANUAL WASHING MACHINE MODEL: WM3431H*/WM3434H* WD-14312RD/WD-14316RD CAUTION

SERVICE MANUAL WASHING MACHINE MODEL: WM3431H*/WM3434H* WD-14312RD/WD-14316RD CAUTION Website: http://www.lgeservice.com [For U.S.A] www.lg.ca [For CANADA] E-mail: http://www.lgeservice.com/techsup.html WASHING MACHINE SERVICE MANUAL! CAUTION READ THIS MANUAL CAREFULLY TO DIAGSE PROBLEMS

More information

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE.

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. website : http://www.lgeservice.com e-mail : http://lgeservice.com/techsup.html WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. MODEL

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE.

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. website : http://www.lgeservice.com e-mail : http://lgeservice.com/techsup.html WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. MODEL

More information

WASHING MACHINE SERVICE MANUAL

WASHING MACHINE SERVICE MANUAL website : http://www.lgeservice.com e-mail : http://lgeservice.com/techsup.html WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. MODEL

More information