Air Handling Units. Catalogue made of expectations

Size: px
Start display at page:

Download "Air Handling Units. Catalogue made of expectations"

Transcription

1 Air Handling Units Catalogue 2006 made of expectations

2 Automatics

3 Automatics Control elements Control applications Supply AHUs Heating: AS1, AS Cooling: AS4, AS Heating, Cooling: AS5, AS Exhaust AHUs Ventilation: AE Supplyexhaust AHUs: crossflow exchanger Ventilation: AP32 (VS 10 15) Heating: AP33 (VS 10 15) Cooling: AP164 (VS 10 15) Heating, Cooling: AP37 (VS 10 15) Ventilation: AP0 (VS ) Heating: AP1 (VS ) Cooling: AP132 (VS ) Heating, Cooling: AP5 (VS ) Supplyexhaust AHUs: rotary exchanger Ventilation: AR Heating: AR Cooling: AR Heating, Cooling: AR Stable operation, easy control he new VENUS AHUs mean a totally new automatics ensuring professional and easy control over ventilation and air conditioning system. It achieves air desired comfort conditions most cost effectively. An easily programmable controller interfacing with the users HMI is the heart of the new system. It guarantees unprecedented comfort and simplicity in regulation of air parameters. It is open to other, external control elements as well.

4 Control elements Function and application Construction Duct sensor Measuring the temperature of supply, exhaust and outdoor air. Securing max. and min. supply air temperature. resistance measuring element installed in an aluminium bayonet probe 25cm long Room temperature sensor Measuring air temperature inside a room. resistance measuring element installed on a printedcircuit board Differential control Control of filters contamination level in a unit measuring the permissible difference of air pressures before and behind the filter. Control of the operation of a fan unit with a belt drive signaling fan s ram effect by means of measuring pressures on the supply and exhaust side of the fan. Control of fan unit operation with a direct drive in case of a unit with electric heater. a membrane coupled with levers mechanism, when an acceptable pressure difference is exceeded, the membrane warps and disconnects electrical contact (filters contamination signal or fan unit operation) casing: plastic Antifrost thermostat on air side Antifrost protection of water heater: based on the measurement of minimum acceptable temperature of air going through a heater. When the minimum air temperature is exceeded, the signal transferred to the controller closes the air damper on air inlet, turns off the fan and opens the water valve to the max. measuring element: capillary with length of 2m for VS m for VS filled with refrigerant thermostat is equipped with adjusting screws which enable setting the minimum operation temperature as well as the temperature when the device switches on again (hysteresis) casing: plastic he thermostat is always installed on the first water heater in the AHU. Overheat protection thermostat Overheating protection for electric heater switching off the heater and automatic resume once the temperature is lowered by the hysteresis value. bimetallic element installed inside metal casing he element constitutes an optional equipment of electric heater. 72

5 Operation parameters HMI BASIC measurement: C measurement accuracy: ±0,5K measuring element: P0 output signal: resistant length of communication wires: max. 150m protection class: IP67 DESCRIPION Air treatment type: cooling heating LCD screen: current temperature on main control sensor given temperature operation mode alarm status he connection between the sensor and control box is made with shielded cable. Edition keys: setting value of temperature measurement: C measurement accuracy: ±0,5K measuring element: P0 output signal: resistant length of communication wires: max. 150m protection class: IP20 he connection between the sensor and control box is made with shielded cable. Built in room temperature sensor Keys of operation mode change: system switched off operation according to the calendar implemented in the controller standby: an AHU goes into operation mode if the set temperature is 2 C higher than the temperature on the main control sensor; analogically the AHU stops its operation when the set temperature exceeds the temperature on the main control sensor by 2 C AHU s operation at 60% of capacity AHU s operation at % of capacity measurement: Pa (filters class G4 F9) rated voltage: 250V AC (Imax=5A) output signal: voltage free (contact) NO or NZ respectively a number of cycles: (in 60 C) protection class: IP54 ambient temperature: C REGULAION OF EMPERAURE Regulation of temperature is carried out as hysteresis value change +/ 4.5 K around nominal temperature of the main sensor, set in the controller. temperature measurement: C antifrost signal setpoint value: +5 C (set by manufacturer) hysteresis: 1,7 12K rated voltage: 30 V DC 230 V AC output signal: voltage free (dry contact) protection class: IP 44 he thermostat s capillary should be installed at the lowest temperature zone of the liquid supplying the exchanger. ALARM SAUS Information on current alarms displayed in the shape of a group and a subgroup of alarm signals, e.g.: group: pressure switches; subgroup: prefilter pressure switch. overheating setpoint value: 65 C hysteresis switch off value: 22K output signal: voltage free (dry contact rated voltage: 20V DC 230V AC 73

6 Control elements Function and application Construction Carbon monoxide (CO) detector Indoor carbon monoxide detection. Exceeding the acceptable threshold carbon monoxide concentration activates the outputs controlling the fan s rotational speed. measuring element with microprocessor circuit installed inside a high rigid casing casing: plastic Optional control element. ONOFF and 010V air damper actuator ON OFF; 0 10V type Airflow open/cut off in air handling unit: ON/Off actuator. Mixing level control for outdoor and roomexhaust air (recirculation): 010 type actuator. Control of bypass air damper opening level for crossflow exchangers antifrost protection of exchanger (VS 21650): 010 type actuator. mechanical system with an electric motor installed inside plastic casing actuator adjusted for installation with a square stem 10 16mm or a round one 10 20mm For air handling units equipped with water heater, the air damper actuator is additionally equipped with a return spring air damper is closed when no supply voltage is present. hreeway valve with electric actuator emperature control of liquid flowing through the water exchanger (heater). Qualitative control: maintaining the constant flow of the liquid supplied to the exchanger, upon its temperature change. Control of mass liquid flow supplied to the exchanger retaining constant temperature cooler (placing the valve on the installation carrying the liquid away from the exchanger). In order to minimize the risk of liquid freezing in the exchanger (heater), integration between the valve and a circulating pump is recommended. Actuator: mechanical system with an electric motor installed inside plastic casing enabling smooth regulation of valve opening Valve: body material: k VS =2,5 63 bronz k VS = spheroidal iron control element: k VS =2,5 63 globule (stainless steel) k VS = grzybek head (stainless steel) kind of connection: hreaded DN15 dla k VS =2,5 10 DN25 dla k VS =16 DN32 dla k VS =25 DN40 dla k VS =40 DN50 dla k VS =63 Flange DN80 dla k VS = Frequency converter Smooth control of the air flow by proportional change of rotational speed of the motor fan unit. Maintaining fixed AHU s operation parameters at variable ductwork s flow resistances. Converter is designed only for VS AHUs as a standard element of fan unit equipment. electronic circuit which enables changing voltage frequency powering motor and maintaining optimum U/f characteristics the circuit is installed inside a plastic casing fan enabling internal cooling of the unit control panel enabling entering the frequency converter s parameters 74

7 Operation parameters HMI ADVANCED supply voltage: 230V AC output signal: 12V DC / max 0.1A voltage free (dry contact) power consumption: 5W protection class: IP 40 ambient temperature: C control type: twopoint open/closed 0% supply voltage: 24 V AC/DC input signal: ON/OFF 0 10 V DC torque: 16 Nm rotation angle: opening duration: ON/OFF: s (spring 10s) 010V: 80 s (spring 10s) number of cycles: max. air damper area: 4 m 2 protection class: IP54 ambient temperature: C DESCRIPION Main page Return to the main page regardless of a current screen display. Back Moving to a previous page or to the beginning of the page that is currently being displayed. Operation mode Choosing AHU s operation mode: Auto (acc. to calendar); On system switched on; Off system switched off; Stby the system switches on and off depending on the difference of temperatures. he fan status is additionally indicated by a green diode: continuous light fans in operatione; diode turned off fans switched off; flashing fans switched off temporarily, they can switch at any time (AUO, Stby). Information on alarms Access to the codes of current alarms. Alarm are indicated by a red diode. Edition keys Setting the value of a chosen parameter. Actuator control range: 0 % supply voltage: 24V AC/DC input signal: 010V DC rated torque: 8Nm for k vs =2,5 63 rated pressure load: 1800N for k vs = rotation angle: opening duration: 30s protection class: IP54 ambient temperature: C Valve operation characteristics: percentage constant/proportional k VS range: 2,5;4;6,3;10;16;25;40;63; average temperature: k VS = 2,5 10: up to 120 C k VS = 16 : up to 140 C glycol percentage in medium: 50% ambient temperature: C Navigation keys up/down Navigation between the parameters displayed on the screen. AHU OPERAION CALENDAR Confirming Moving to subsequent pages. Entering the edition of a chosen parameter value mode. ime zones control range: 10 Hz supply voltage: 1 and 3 phase V AC 3 phase V AC frequency range: Hz control terminals (programmable): 2 analogue inputs 0(2) 1 V, 0(4) 20mA 1 analogue output 0(4) 20mA 5 digital inputs 12V DC v 24V DC 2 relay outputs V DC/30V DC serial communication: Modbus RU Protocol motor connection: 3phase ambient temperature: 0 40 C protection class: IP21 Frequency converters conform with EMC Directive 89/336/EEC (RFI filters for the secondary environment are not required). ime zone parameters Programming operation parameters for the AUO mode with the possibility of dividing days with respect to time zones and assigning each of them with a desired ventilation air temperature acc. to the main sensor, value of air flow capacity, recirculation level, AHU operation status. 75

8 Control elements Function and application Construction Rotational speed regulator Maintaining controlled ventilation unit s air capacity by proportional change of rotational speed of the motor which is coupled with the fan. thyristor circuit installed inside plastic casing rotational speed regulator power switch he regulator is used only in VS AHUs as a standard element of the fan set. HMI BASIC user s room interface Control of the air temperature in a room. Displays ventilation and read out of a ventilation and air handling unit s operation parameters: air parameters; efficiency change (three stages); SAR/SOP; optional control element. electronic circuit with a resistance measuring element installed inside plastic casing LCD screen control panel Optional control element. HMI ADVANCED user s external interface Displays ventilation and read out of a ventilation and air handling unit s operation parameters: Air parameters; Efficiency change (smooth); recirculation level; work schedule set up; SAR/SOP; breakdown states. Managing operation of one or more AHUs from any location in a building by means of serial communication with a controller (controllers). electronic circuit installed inside plastic casing LCD screen control panel communication cable (15m) Optional control element. VS supply and supplyexhaust air AHU control box Regulation, control, protection of ventilation or air conditioning units operation parameters operation, temperature, air efficiency, breakdown states. Scheduled operation of a unit (in accordance with calendar) with a possibility of division into time zones. Control of unit s operation from any location in a building with the help of external communication elements HMI BASIC or HMI ADVANCED user s interface. Cooperation with external circuits in the field of: SAR signal; fire alarm; SAR/SOP system. set of elements protecting motors operation driver main disconnector metal casing, dimensions: 400x400x130mm 500x500x130mm VS exhaust AHU control box Regulation, control, protection of ventilation unit s operation parameters operation, breakdown states. Cooperation with external circuits in the field of: SAR signal; fire alarm; SAR/SOP system; CO detector. set of elements protecting motors operation main disconnector steering and control panel with a rotational speed controller metal casing, dimensions: 400x400x130mm 76

9 Operation parameters HMI ADVANCED AHU OPERAION MODE speed control range: 0 % supply voltage: 230V AC / 50 Hz controlled load voltage: V slowblow fuse: 6,3 A protection class: IP21 ambient temperature: 0 50 C supply voltage: 12 15VDC emperature measurement measurement: 0 40 C measurement accuracy: +0,5K measuring element: NC output signal: resistant length of communication cable: max. 50m protection class: IP30 operation conditions: 0 50 C / φ<85% Mode: On Off Stby Auto Information on a selected AHU operation mode. On switched on: AHU is working in accordance with the settings on the control panel. Off switched off: fans stopped, air dampers and control valves closed. All sensors and measuring elements are active. Potential alarms are indicated. Stby standby: An AHU goes into operation mode if the set temperature is 2 C higher than the temperature on the main control sensor. Analogically the AHU stops its operation when the set temperature exceeds the temperature on the main control sensor by 2 C. Auto: AHU s operation is regulated by specific time settings. supply voltage: 12V DC external communication: serial port standard: RS232 length of communication cable: max. 15m protection class: IP50 operation conditions: C / φ<85% Mode: On Off Heating Cooling PreHeating Information on a current AHU operation mode. On AHU switched on (only fans in operation). Off AHU switched off. Heating heating process initiated. Cooling cooling process initiated. PreHeating initial heating, the function is active while an AHU is being started. It prevents low temperature air from being sucked into an AHU. emp Setup: C. Information on the set air temperature. Main emp: C. Information on the set air temperature around the main sensor. MENU Moving to a window with a list of available parameters and settings. supply voltage : 3x400V or 1x230V AC frequency: 50Hz + 1Hz control voltage: 24V AC ALARM SAUS Driver external communication Serial port standard: RS232 standard: RS485 protocol: ModbusRU LonWorks network interface standard: F10A protocol: Lonalk protection class: IP54 ambient temperature: 0 40 C Filter s pressure switch Antifrost thermostat supply voltage : 3x400V or 1x230V AC frequency: 50Hz + 1Hz control voltage: 24V AC protection class: IP54 ambient temperature: 0 50 C Access to the current alarms code library where a user can find out about the time of a specific alarm and a kind of danger e.g.: activation of pressure switches of filters or the fan unit; a signal from the antifrost thermostat; activation of a shortcircuit or overload protection; signal of overheating of an electric heater. 77

10 Control applications Supply AHUs S2F S3F 1M2 Y1 S2F S3F 1M2 Y1 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 78

11 Control applications Supply AHUs Y 2 Y 2 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 79

12 Control applications Supply AHUs S2F S3F 1M2 Y1 Y 2 S2F S3F 1M2 Y1 Y 2 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 80

13 Control applications Exhaust AHUs Control Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Air flow control depending on CO condensation ratio. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Fan unit protection the function is active: for the fan unit with belt drive; Overload protection of a drive unit. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 81

14 Control applications Supplyexhaust AHUs: crossflow exchanger S2F S3F 1M2 Y1 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 82

15 Control applications Supplyexhaust AHUs: crossflow exchanger Y 2 S2F S3F 1M2 Y1 Y 2 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 83

16 Control applications Supplyexhaust AHUs: crossflow exchanger S2F S3F 1M2 Y1 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 84

17 Control applications Supplyexhaust AHUs: crossflow exchanger Y 2 S2F S3F 1M2 Y1 Y 2 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 85

18 Control applications Supplyexhaust AHUs: rotary exchanger S2F S3F 1M2 Y1 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 86

19 Control applications Supplyexhaust AHUs: rotary exchanger Y 2 S2F S3F 1M2 Y1 Y 2 Control Indoor temperature control (HMI BASIC), optional for supply/exhaust air. Control of the energy recovery level first stage of heating/cooling. Air flow control (frequency converter for VS or rotational speed regulator for VS 1015). Operation according to calendar temperature, efficiency, operation mode (OPERAION, SANDBY, SOP). SANDBY maintaining the minimum, set indoor temperature. Information Information on outdoor, supply, exhaust and indoor air temperatures. Filter contamination info. Alarm status info. Analog and digital output status info. Protection Limiting the allowed supply air temperature. Fan unit protection the function is active: for the fan unit with belt drive; if an electric heater is applied. Overload protection of a drive unit. Antifrost protection of a water heater. Protection against overheating of an electric heater. Antifrost protection of an energy recovery exchanger. he control application layouts have been prepared on the basis of water exchangers. he quantity of applied pressure switches for filters depends on the filters configuration (p. 57). 87

20 Psychrometric chart air temperature 88

21 Climate parameters CHINA CZECH REPUBLIC ESONIA KAZAKHSAN LIHUANIA LAVIA GERMANY POLAND RUSSIA SLOVAKIA UKRAINE HUNGARY UNIED ARAB EMIRAES EUROPE WORLD Country Peking Shanghai Prague Brno Ostrava allin Almaata Astana Vilnius Klaipeda Riga Berlin Frankfurt Hamburg Munich Warsaw Gdansk Krakow Przemysl Suwalki Moscow St. Petersburg Samara Kazan Jekaterynburg Krasnodar Rostov Nizni Novogrod Krasnoiarsk Irkutsk Vladivostok Omsk Perm Novosybirsk Murmansk Bratislava Kosice Kiev Doneck Odessa Dnepropietrovsk Lvov Budapest AbuDhabi Dubai Bucharest Paris Amsterdam Minsk Vienna London Amman ArRijad Muscat Kuwait Bombay Delhi Washington Montreal own Above sea level [m] Pressure [kpa] * Relative humidity has been accepted for winter period conventionally. Summer Winter emperature Enthalpy Relative emperature Enthalpy Relative [ C] [kj/kg] humidity [%]* [ C] [kj/kg] humidity [%]* Optional functions and accessories Optional functions L VS E m h x w h [mm] 2 x w E 2 [kg] [mm] [mm] x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x L VS M m h [mm] 2 x w 2 h 3 x w M 3 [kg] [mm] [mm] x x x x x x x x x x x x x x x x x x x x x x x x x x x x Accessories E empty section M mixing box FC flexible connection AD air damper VS L S [mm] m S [kg] VS L F [mm] S silencer F secondary filter m F [kg]

22 VS worldwide VS Polska Sp. z o.o. Słonecznikowa Kosakowo Poland tel.: fax: gdynia@vtsclima.com

Our international references

Our international references Our international references made of expectations EDITION 2013 VTS EDITION 2013 Catalogue Air andling Units IN Climate parameters Country Town Above sea level [m] Pressure [kpa] Summer Winter Temperature

More information

Our international references. made of expectations EDITION VTS EDITION Catalogue. Air Handling Units

Our international references. made of expectations EDITION VTS EDITION Catalogue. Air Handling Units Our international references made of expectations EDITION 2013 VTS EDITION 2013 EN Catalogue Air andling Units Addresses: VTS POAND Al. Sikorskiego 11 02758 Warszawa Tel.: +48 22 431 37 00 Fax: +48 22

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650 Catalogue 2015 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 2.1 Water heaters 2.2 Product range 2.3 Technical parameters 2.4 Destratificator VR-D 03 CONTROLS

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING TRA DITIONS AND INNOVATION Since 1922 The first LOVATO Electric headquartes founded in Bergamo in 1922: the starting point of the grand industrial

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers 1 37 Room Unit for use with heating controllers Digital, multi-functional room unit for the convenient operation of heating controllers from the living room. A setpoint knob and an economy button allow

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 domekt rego / recu LT RU Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34 Content 1. ELECTRICAL INSTALLATION

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3005925_2018-02-05.fm EXcon zone control Control for up to 4 individual zones EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk OJ-Air2

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller 2 252 Self-learning Room emperature Controller with one weekly operating mode including individual 24-hour modes and three 24-hour modes, cooling function REV22 Use Mains-independent room temperature controller

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

Pre-programmed room controller with communication

Pre-programmed room controller with communication revision 02 2016 RC-C3 Pre-programmed room controller with communication RC-C3 is a complete pre-programmed room controller from the Regio Midi series intended to control heating and cooling in a zone

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller PB_ER65-DRW_ 202 ER65-DRW Controller Heating Applications Product Bulletin The controller is a digital device for domestic or residential heating units. It covers water and air heating applications. All-in-one

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

Attractive price On stock availability Monocoque technology DUCT AIR CONDITIONING

Attractive price On stock availability Monocoque technology DUCT AIR CONDITIONING Attractive price On stock availability Monocoque technology DUCT AIR CONDITIONING VENTUS N-TYPE Finland Denmark Germany The Netherlands Czech Poland Estonia atvia ithuania Slovakia Belarus Ukraine Russia

More information

Operating Manual RCM420

Operating Manual RCM420 Operating Manual RCM420 Residual current monitor for AC current monitoring in TN and TT systems Software version: D240 V1.2x TGH1410en/03.2012 Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany

More information

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W) Refrigeration Dryer 66 (-W) bis 2400 (-W) Version: 1.0.1 Author: Karsten Unger Date: 20.09.2013 Field of application Refrigeration dryers of the series are designed for drying compressed air flows up to

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

Pre-programmed room controller with communication and hidden setpoint

Pre-programmed room controller with communication and hidden setpoint revision 02 2016 RC-C3H Pre-programmed room controller with communication and hidden setpoint RC-C3H is a complete pre-programmed room controller from the Regio Midi series intended to control heating

More information

FIL-SPL Flow-through heater for central heating USER MANUAL

FIL-SPL Flow-through heater for central heating USER MANUAL FIL-SPL Flow-through heater for central heating with 0-10 V EP 15-30 control unit USER MANUAL Kaukora LTD. D106159 r3.0 Contents 1. Important information... 5 Safety information... 5 General... 5 Marking...

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 483586 Microprocessor Controller for Dedicated Outdoor Air System Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Control solutions Biofloor

Control solutions Biofloor TEF234 Electronic room thermostat with display 230V & 24V COMAP proposes a new control system for heating and cooling underfloor. Consisting of a 6 or 10- channels controller (MCF234), analogic (TAF234)

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

Application guide RDG160 Remote control

Application guide RDG160 Remote control Application guide RDG160 Remote control Providing indoor climate comfort RDG160-AGU-0509-E RDG100/RDG110 RDG140/RDG160 RDG100 Wall-mounted Room hermostats with Display for fan coil units application for

More information

Compressors Manufacturing Company Ltd.

Compressors Manufacturing Company Ltd. Compressors Manufacturing Company Ltd. SCREW COMPRESSORS 2 SCREW COMPRESSORS The screw compressors are ready for operation and fully automatic units designed for continuous operation in harsh operating

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans! AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range

More information

CLEVER CONTROL Version: V3

CLEVER CONTROL Version: V3 CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

S304 and S305 Dust Emission Monitors. User Manual. Distributor

S304 and S305 Dust Emission Monitors. User Manual. Distributor S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

Process Alarm Module RTA 421

Process Alarm Module RTA 421 Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders

More information

HEATING AND VENTILATION UNITS CONTROL AND AUTOMATICS

HEATING AND VENTILATION UNITS CONTROL AND AUTOMATICS CONTROL AND AUTOMATICS 1 1. OVERVIEW OF AUTOMATIC CONTROL DEVICES Automatic control of heating and ventilation equipment is responsible for the maintenance of the required air parameters and the reduction

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. SHORT DESCRIPTION: 1. Device is applicable to: - Burners; - Electric boiler;

More information

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PolyGard Digital Gas Controller DGC-05 RS-485 Bus PolyGard Digital Gas Controller DGC05 RS485 DESCRIPTION Gas measuring controller series for continuous monitoring and warning of toxic, combustible and refrigerant gases and vapours. The gas controller

More information

Immersion Temperature Controller

Immersion Temperature Controller 3 333 Synco 100 Immersion emperature Controller with 2 outputs DC 0 RLE162 Immersion temperature controller for water-side control in heating and cooling plants Compact design with 2 analog control outputs

More information

UNIVERSAL CONTROL CABINET FOR MCKT UNITS WITH UNIAPPMCKT APPLICATION LG, DANFOSS, EBM

UNIVERSAL CONTROL CABINET FOR MCKT UNITS WITH UNIAPPMCKT APPLICATION LG, DANFOSS, EBM GDYNIA AUTOMATIC CONTROL CABINET FOR MCKT ENG_2017 1/51 UNIVERSAL CONTROL CABINET FOR MCKT UNITS WITH UNIAPPMCKT APPLICATION LG, DANFOSS, EBM SERVICE Tel.: (+48 58) 783 99 50/51 Fax: (+48 58) 783 98 88

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

CMD420 / CMD421 Series

CMD420 / CMD421 Series 3 T M CMD420 / CMD421 Series Digital Current Relay (Overcurrent and Undercurrent) For Three-Phase AC Systems Technical Bulletin NAE1032810 / 06.2016 CMD420 / CMD421 Digital overcurrent and undercurrent

More information

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004

More information

REA22 Room Temperature Controller

REA22 Room Temperature Controller REA22 Room Temperature Controller Basic Documentation Issue: 2.0 Controller series: A CE1P2276E 31.03.1999 Siemens Building Technologies Landis & Staefa Division Siemens Building Technologies Ltd. Landis

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH EN M-Sens 2 Operating Instructions Online-Moisture Meter for Solids SWR engineering Messtechnik GmbH CONTENTS Page 1. System Overview......................................................................

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs

More information

Chlorine gas leak detector

Chlorine gas leak detector INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o. 1 CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays...

More information

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, Option External Input s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

ER65 - Mini Rack Controller Electronic Refrigeration Line

ER65 - Mini Rack Controller Electronic Refrigeration Line PB_ER65_ 00 ER65 - Mini Rack Controller Electronic Refrigeration Line Device is a multi-stage digital controller. It is typically applied to small refrigeration rack units piloting compressors or condenser

More information

The integral solution for. Air Handling Units. Technology & Evolution

The integral solution for. Air Handling Units. Technology & Evolution The integral solution for Air Handling Units Technology & Evolution For over 25 years Carel has been dealing with the design and production of electronic controllers and supervision systems for Air-Conditioning

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with ICH-compliant illumination KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

Key benefits. Why Condair CP3?

Key benefits. Why Condair CP3? Condair Cp3 Humidification The Electrode Steam Humidifier. Powerful and User-Friendly Why? Tailored technology. You can program your specifications exactly to the last kilogram with the CP3 Card. This

More information

XLH210: controller for gas leak detectors

XLH210: controller for gas leak detectors pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

Room thermostats with LCD for wall mounting

Room thermostats with LCD for wall mounting s 3 181 RDG100 / RDG110 RDG140 / RDG100 RDG100/H Room thermostats with LCD for wall mounting for fan coil unit applications for universal applications for use with compressors in dx type equipment RDG1

More information

EC3-X33 Stand-alone Superheat Controller Technical Data

EC3-X33 Stand-alone Superheat Controller Technical Data Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

product overview ProControl

product overview ProControl product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.

More information

Operating Manual UV Monitor UVT 18

Operating Manual UV Monitor UVT 18 Operating Manual UV Monitor UVT 18 Software Version 1.2 stand: 21/11/2016 UV - Monitor UVT 18 Intended use The signal monitor UVT 18 was developed to control small- and medium-sized UV systems and is fully

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

Wireless room thermostat with LCD

Wireless room thermostat with LCD s 1 424 RDD100.1RF RCR100RF Wireless room thermostat with LCD for heating systems RDD100.1RFS Roomom temperature control Comfort, Economy and Protection mode 2-position control with On/Off control output

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626) PF1000 CONTROLLER for the AQUARIUS I/II DEIONIZED WATER HEATING SYSTEM Heateflex Corporation 405 E. Santa Clara St. TEL: (626)599-8566; FAX: (626)599-9567 Rev. 07 10/19/10, (PF1000) 1 2 TABLE OF CONTENTS

More information