SUPPLEMENTARY INSTRUCTION BOOKLET HEATER TYPE TR. Centrifugal / Rooftop

Size: px
Start display at page:

Download "SUPPLEMENTARY INSTRUCTION BOOKLET HEATER TYPE TR. Centrifugal / Rooftop"

Transcription

1 GB139d SUPPLEMENTARY INSTRUCTION BOOKLET HEATER TYPE TR Centrifugal / Rooftop READ THIS DOCUMENT BEFORE COMMENCING INSTALLATION. THE USER MUST BE INSTRUCTED IN USING THE APPLIANCE. KEEP THIS DOCUMENT NEAR THE APPLIANCE. Instructions TR series Centrifugal & Rooftop version GB 139d date:

2 Contents 1 FOREWORD 4 2 DESIGN TR-SERIES (STANDARD HEATERS) TR-A SERIES TR-A with duct connection on front TR-A with fan box TR-C TR HEATER WITH CENTRIFUGAL FAN TR-C Basic version: TR-C with Fan box: TR-R ROOFTOP UNIT: 6 3 TECHNICAL DATA 7 4 INSTALLATION GENERAL: SUSPENSION / POSITIONING Suspension TR C basic and TR C with Fan box Positioning TR R Rooftop DUCT CONNECTION: Air resistance and accessories Minimum distance to bends or other appendages Air Duct EXAMPLES OF INDUSTRIAL INSTALLATIONS 10 5 ELECTRICAL CONNECTION GENERAL VAC VERSION PHASE 400VAC VERSION 11 6 ADJUSTING THE VENTILATOR EXCESS AMPERAGE, TOO MUCH AIR DISPLACEMENT INSUFFICIENT AIR DISPLACEMENT 12 7 ELECTRICAL DIAGRAM TR-A VAC VERSION WITH EXTERNAL THERMAL SAFETY DEVICE PHASE 400VAC VERSION PHASE 400VAC VERSION WITH SOFT STARTER 16 8 DIMENSIONS TR24 & 28 CENTRIFUGAL / ROOFTOP TR24 C & 28 C Basic TR24 & 28 A / C Fanbox TR24 R & TR28 R Rooftop TR40 & 50 CENTRIFUGAL / ROOFTOP TR40 & 50 C Basic TR40 & 50 A / C Fanbox TR40 & 50 R Rooftop TR60 & 80 CENTRIFUGAL / ROOFTOP TR60 C & 80 C Basic TR60 & 80 A /C Fan box TR60 R & 80 R Rooftop TR100 CENTRIFUGAL / ROOFTOP TR100 C Basic TR100 A / C Fan box TR100 R Rooftop TR125 CENTRIFUGAL / ROOFTOP TR125 C Basic TR125 C Fanbox TR125 R Rooftop 31 Annex to Instructions TR Centrifugal Version GB 139d Page 2/41

3 8.6 TR150 CENTRIFUGAL / ROOFTOP TR150 C Basic TR150 C Fanbox TR150 R Rooftop CONSTRUCTION FRAMES Rooftop Frame TR24 R 50 R C Frame TR24 R 50 C / R Rooftop frame TR60 R-150 R C Frame TR C / R TR ROOFTOP + AIR OUTLET MODULE TR24 R - 50 R Rooftop + Air outlet module TR60 R R Rooftop + Air outlet module TR125 R R Rooftop + Air outlet module 41 Annex to Instructions TR Centrifugal Version GB 139d Page 3/41

4 1 Foreword These operating and installation instructions are a supplement for the TR series heater combined with a ventilator for systems which require greater external pressure. TR: Standard series with standard axial fan o No possibilities for extra air accessories TR-A: Heater with more powerful axial fan o Limited possibilities for extra air accessories. Maximum pressure 60Pa Duct outlet (max 60Pa) Fan box with dampers and/or filters No combination of these 2 options possible TR-C: Heater with centrifugal fan. o External pressures up to 0Pa (higher values on request) o Different accessories possible Duct inlet / outlet connection Fan box with optional dampers and/or filter panels Rooftop version Combinations of above. This installation and user manual for the TR heater is the leading document for the installation of this appliance. These operating and installation instructions deal with the specific matters that apply to supplementary use and installation of a centrifugal design. 2 Design 2.1 TR-series (standard heaters) These are standard TR heaters. There are NO air accessories available. The fans behind these units cannot cope with higher air resistance. 2.2 TR-A series These heaters have more powerful axial fans and can cope with external pressures up to 60Pa. This gives the possibility to add air accessories. Available models are 24 to 100kW TR-A with duct connection on front. The heater pulls its air from the room and blows it into an air duct. This duct needs to be dimensioned in such a way that the static pressure inside this duct does not exceeds 60Pa. Warning: When the air resistance in the duct is too high, the amount of air over the heater will reduce too much and the heat exchanger will overheat. This can lead to permanent damage of the heater!! TR TR-A duct connection max60 Pa TR-A with fan box The TR heater sucks its air from a fan box from behind. Dampers and or filters can be mounted in this box, depending on the customer demands. The heater blows the air direct into the building. Annex to Instructions TR Centrifugal Version GB 139d Page 4/41

5 In this configuration it is not possible that the air is distributed through a duct system. This would give too much air resistance and would lead to overheating the heat exchanger. Warning: When the air resistance in the duct is too high, the amount of air over the heater will reduce too much and the heat exchanger will overheat. This can lead to permanent damage of the heater!! TR heater Filter + dampers Filter + dampers 2.3 TR-C TR heater with centrifugal fan The TR air heater with centrifugal system ventilator(s) is available with the following pressure: 60, 120, 180, 240 and 0 Pa. The pressure level of the heater is selected depending on the air resistance in the installation TR-C Basic version: TR-C heater with centrifugal fan is used to blow into a duct system. The duct connection is standard on this heaters Centrifugal fan with motor TR heater TR-C with Fan box: TR Heater Filter + Damper Filter + Damper Annex to Instructions TR Centrifugal Version GB 139d Page 5/41

6 The heater pulls its air from a fan box. In this fan box dampers and or filters can be mounted on customer demands. The unit can blow its air in a duct system or free into the room Outlet: - Flange connection for ducting (standard) - Discharge grill on front (optional) Suction, inlet side: - unrestricted suction (basic version) - Fan box with on either top or bottom and/or rear side flange connection for ducting - Optional: dampers with interlink fresh and recirculation air and filter sets. Construction frame: - C frame: optional Additional: - Isolation Fan box: optional - Soft starter standard: 3-Phase 400 Vac version from 2,2 kw motor power capacity. 2.4 TR-R Rooftop unit: TR air heater with centrifugal ventilator, fan box and Rooftop construction frame Fresh air Filter + Damper Recirculation air Filter + Damper Discharge, outlet side: - Flange connection for ducting (standard) - Air outlet module, see 8.8 Suction, inlet side: - Fan box with on either top or bottom and/or rear side flange connection for ducting - Optional: dampers with interlink fresh and recirculation air and filter sets. Construction frame: - Rooftop frame - C Frame (optioneel) Additional: - Isolation heater + Fan box: standard - Soft starter standard: 3-Phase 400 Vac version from 2,2 kw motor power capacity. - Frost protection burner compartment : optional Annex to Instructions TR Centrifugal Version GB 139d Page 6/41

7 3 Technical data System fan: Axiaal 1-Fase 2 Vac / 50 Hz Type: TR24 A TR28 A TR40 A TR50 A TR60 A TR80 A TR100 A Ext. Press Airflow max. m3/h max 60Pa Throw horizontal max. m Voltage(@50 Hz) V Absorbed power W Amps A 1,3 1,3 2 2,6 2,5 3,3 4,8 Weight TRA basis kg TRA ventilatoromkasting kg Centrifugal fan 1-Fase 2 Vac / 50Hz Type: TR24C TR28C TR40C TR50C TR60-2C TR80-2C TR100-2C TR125-2C TR150-2C ext. Pressure Air output max. m3/h p [Pa] Throw horizontal m Electrical supply (50 Hz) V n.v.t. n.v.t. Power consuption W Power consuption motor nom. A 2,5 2,5 3,6 4,7 4,0 4,7 5,2 Power consuption motor max. A 3,1 3,1 4,2 5,5 5,5 5,5 7,3 120 Electrical supply (50 Hz) V n.v.t. n.v.t. Power consuption W Power consuption motor nom. A 2,8 2,8 3,9 4,9 4,8 5,7 6,5 Power consuption motor max. A 3,1 3,1 4,2 5,5 5,5 7,3 7,3 180 Electrical supply (50 Hz) V n.v.t. n.v.t. Power consuption W Power consuption motor nom. A 3,1 3,1 4,7 5,1 5,6 7,9 8,5 Power consuption motor max. A 4,2 4,2 5,5 5,5 7,3 9,9 9,9 240 Electrical supply (50 Hz) V n.v.t. n.v.t. n.v.t. Power consuption W Power consuption motor nom. A 3,9 3,9 4,9 6,0 8,1 8,1 Power consuption motor max. A 4,2 4,2 5,5 7,3 9,9 9,9 0 Electrical supply (50 Hz) V n.v.t. n.v.t. n.v.t. n.v.t. Power consuption W Power consuption motor nom. A 4,4 4,4 5,7 6,6 8,6 Power consuption motor max. A 5,5 5,5 7,3 7,3 9,9 Centrifugal fan 3-Fase 400 VAC / 50Hz Type: TR24C TR28C TR40C TR50C TR60-2C TR80-2C TR100-2C TR125-2C TR150-2C ext. Pressure Air output max. m3/h p [Pa] Throw horizontal m Electrical supply (50 Hz) V Power consuption W Power consuption motor nom. A 0,9 0,9 1,3 1,8 1,6 1,8 2,1 3,9 4,4 Power consuption motor max. A 1,1 1,1 1,5 2,1 2,1 2,1 2,8 5,1 5,1 120 Electrical supply (50 Hz) V Power consuption W Power consuption motor nom. A 1,0 1,0 1,4 1,9 1,9 2,3 2,6 3,9 4,5 Power consuption motor max. A 1,1 1,1 1,5 2,1 2,1 2,8 2,8 5,1 5,1 180 Electrical supply (50 Hz) V Power consuption W Power consuption motor nom. A 1,1 1,1 1,8 2,0 2,3 2,9 3,0 4,4 5,0 Power consuption motor max. A 1,5 1,5 2,1 2,1 2,8 3,7 3,7 5,1 6,3 240 Electrical supply (50 Hz) V Power consuption W Power consuption motor nom. A 1,4 1,4 1,9 2,3 3,0 3,0 3,4 4,8 6,5 Power consuption motor max. A 1,5 1,5 2,1 2,8 3,7 3,7 5,1 6,3 8,3 0 Electrical supply (50 Hz) V Power consuption W Power consuption motor nom. A 1,7 1,7 2,2 2,6 3,2 3,3 4,1 6,5 7,0 Power consuption motor max. A 2,1 2,1 2,8 2,8 3,7 5,1 5,1 8,3 8,3 Weight TR C TR24C TR28C TR40C TR50C TR60-2C TR80-2C TR100-2C TR125-2C TR150-2C TRC basic kg TRC with Fan box kg TRC rooftop kg Dimensions, see Chapter 8. Annex to Instructions TR Centrifugal Version GB 139d Page 7/41

8 4 Installation 4.1 General: General installing instructions are provided in the TR instruction manual for appliances with axial ventilators. This supplementary booklet presents specific installing instructions for the centrifugal and rooftop version of the TR. The appliance must have a clear suck and throw. If these are blocked the heater will overheat. There should not be materials within 5m in front of the heater when there is a free outlet. Pay particular attention to flammable materials Take into account the possibility to open the door of the heater for necessary service and maintenance work. Make sure that after fitting, there is no mechanical tension on any connected gas or electrical supplies. 4.2 Suspension / positioning Suspension TR C basic and TR C with Fan box The heater is provided with fixing points for suspension, consisting of 4 or 6x M10 threaded sockets on top. Check and make sure that the support is strong enough. For the TR C with Fan box there is an C frame optional available. (8.7.2 / 8.7.4) Positioning TR R Rooftop The TR Rooftop must be placed on a so called platform. - Rooftop frame - C frame (optional) See example drawing of the rooftop frame Chapter 8.7. Check if the support is strong enough. 4.3 Duct connection: The discharge side of the heater has a connection flange on which a duct can be fixed with M5 bolts. Dimensions: see chapter 8. The Rooftop version is also optional available with a discharge down flow module Air resistance and accessories TR Heater Filter + Damper Filter + Damper Annex to Instructions TR Centrifugal Version GB 139d Page 8/41

9 Application of basic accessories can imply following resistance losses: Fan box 20 Pa Dampers 10 Pa Filter panel (Class EU2), clean 40 Pa Fresh air grill 10 Pa Discharge down flow module 20 Pa Minimum distance to bends or other appendages It is essential that the heat exchanger is being blown equally over the full frontal surface. If the air, for example only covers the lower part of the exchanger, the upper region will probably get no cooling and get overheated. De TR C heater should have at least 1 meter of straight duct with a cross section that is equal to that of the flange connection, behind the exchanger. If these conditions are not being fulfilled, the heat exchanger will get thermally overloaded. This will result in heater errors and damage to the exchanger (shorter lifetime). This can mean invalidation of warranty! Air Duct This paragraph gives a general representation of the requirements a simple duct system must meet. The reader is referred to specialist installers for accurate calculations of more complicated systems. The table below shows the diameter of the appropriate size round air duct (standard sizes for spirally seamed ducting) for the given air displacement [m3/h] and acceptable speed of the air [m/sec]. The ducts must be airtight, internally smooth and sufficiently heat resistant. The ducting connection to the heater must be made of metal for a length of no less than 2 meters and run smoothly into the connector sizes of the appliance without any buffeting edges. Bends in square section ducts must be provided with baffles conducting the air. Sizes and the resistance of air grilles must be requested from the manufacturer. Air displacement m 3 /h Air speed m/s 6,5 6,5 6,3 6,3 5,6 5,4 5,4 4,9 4,5 4,3 3,5 3,6 3,5 3,1 3,1 2,7 2,8 Duct size (mm) Round or square Annex to Instructions TR Centrifugal Version GB 139d Page 9/41

10 4.4 Examples of industrial installations An installation with warm air blowing into two or more spaces must provide for the used air to return to the heater. A heater that is installed in a separate space with ducts connected to a the adjacent room. A heater with fresh air supply and return connection. The fresh air to indoor air ratio can be linked and adjusted by hand or by means of a stepped control and servo motor. The return and/or outside air can be potentially filtered. Annex to Instructions TR Centrifugal Version GB 139d Page 10/41

11 5 Electrical Connection 5.1 General The installation must comply with the local and/or national regulations. Ensure that it is connected to the correct consumer group protected by a MCB / RCD or main fuse. The wiring diagram for the appliance can be found at the end this manual (chapter 7). Isolating switch or plug The appliance must be equipped with a Volt isolating switch which interrupts the phase(s) and the neutral (but not the earth connection). This isolating switch must have a contact gap of at least 3 millimeters. If the appliance is provided with a plug for use in a wall socket, the wall socket must be within reach at all times. NEVER interrupt the power supply to the appliance with other switches. This could lead to overheating of the appliance Vac Version The supply is 2Vac. (50Hz) with earth connection. 2V Version with ventilator motor and external thermal safety device. This appliance employs Electrical diagram 7.1. The thermal safety feature in the current supply to the motor will trip when this motor is under excess load and the entire appliance will cease operation including burner and ventilator. The control of the appliance will also cease to operate and the thermostat control will not show a display. When the thermal fuse has cooled down the thermostat can be switched on again and the current will start the controls Phase 400Vac Version The supply is 3 x 400Vac (50Hz) with Neutral and Earth Neutral is also required for the smooth running of the appliance controls. After connecting the appliance, the direction of rotation of the ventilator must first be checked. If this is incorrect, the 2 phases must be changed round in the supply to the appliance. The ventilator has a thermal safety device in the current supply to the motor. This appliance employs Electrical diagram 7.2. The thermal fuse in the current supply to the motor will trip when thr motor is under overload and the entire appliance will cease operation including the burner and ventilator. The control of the appliance will also stop and the thermostat will not show a display. When the thermal fuse has cooled down, the power can be switched back on again and the unit will start. The TR heaters with a centrifugal ventilator from 2,2 kw motor power capacity is standard provided with a soft starter (Electrical diagram 7.3). For versions with the centrifugal motor power capacity smaller then 2,2 kw the soft starter is optional. Annex to Instructions TR Centrifugal Version GB 139d Page 11/41

12 6 Adjusting the ventilator In order to prevent overload of the electric motor, the ventilator has been set to a certain speed in the factory that is correct for the static pressure to be delivered by the appliance. This pressure is printed on the type plate. A feature of these ventilators is that increased air displacement also demands more amps to the motor. If the resistance of the air in the system is in practice lower than the static pressure setting of the air heater, the displacement of air in the ventilator will increase. This could lead to overload of the ventilator motor and hence to the appliance tripping out. Check the amperage of the ventilator motor. This needs to be lower than the maximum amperage printed on the type plate of the electric motor and/or the Technical Data. Always check the direction of rotation of 3-phase motors! 6.1 Excess amperage, too much air displacement When the amperage is too high the ventilator speed must be reduced or the static pressure must be increased. The speed of the motor is not adjustable in three-phase current. In that case resistance in the ducting system should be increased by means of a choke or a reducing valve, which in turn will displace less air and reduce the amperage. Refer to the table with Technical Data. Reducing the revolutions can only be done by changing the pulley and V-belts. Also check this with an amp meter and an air reading if possible. The air speed will increase proportionally when ducts have to be used that are narrower than shown in the table. The resistance will increase by the root mean square. For example: Speed 1.2 x higher Resistance 1.2 x 1.2 = 1.44 higher Important! If an air heater is intended to be connected to a duct system with a high static pressure this must not under any circumstances be implemented with unrestricted air diffusion without taking further measures. This will inevitably lead to the electric motor cutting out. Refer to the Technical data for the maximum air displacement, the static air capacity and the maximum amperage of the ventilator motor. 6.2 Insufficient air displacement The appliance will not displace a sufficient amount of air when the resistance in the system is too high. This is not a problem for the ventilator but the heat exchanger in the appliance can become too hot and will cut out because of overheating. In that case the resistance in the system must be reduced or the ventilator must run at higher revolution speeds. This can influence the choice of motor. Always contact the manufacturer in cases like these. Annex to Instructions TR Centrifugal Version GB 139d Page 12/41

13 7 Electrical diagram 7.1 TR-A L N Temperatuur voeler toestel 20K@25 C -T K@25 C 3 Temperatuur voeler wisselaar -T 20K@25 C -T J Instalateur bruin blauw groen/geel M1 M zwart 8 J2 J J T2 J Wit wit paars blank rood wit groen groen/geel Neutaal L (2V AC) bruin wit Druk schakelaar dp geel geel bruin wit groen geel ON 0 S Micro schakelaars S2 standaard 1op ON, en S3 op 1. Bij meerdere toestellen op één thermostaat, elk volgend toestel een eigen nummer geven (2 t/m 8). En alleen in toestel nr 1 S3 op 1 zetten, bij andere toestellen S3 op STB alleen van toepassing bij: TR20, TR60, TR80, TR100 anders brug 11 M groen/geel blauw zwart grijs blauw groen/geel zwart blauw zwart S2 gasklep ventilator 22 C Thermostaat (Argus link) M3 optioneel F2 2 x 5AT F HA J7 J Wit DC SIT groen groen groen groen Rookgasventilator Shield Modulatie spoel R2 R3 4k7 1k 4 5 LED 1 rood (opt.) LED 2 groen (opt) Toestel herkenning 22 C Get: MF Date: Ver: C Auth: Thermostaat (Argus Link) Title: Nr.: TR series / 1c NL R120 Annex to Instructions TR Centrifugal Version GB 139d Page 13/41

14 7.2 2Vac version with external thermal safety device Neutal L1 green/yellow blue brown C -T K@25 C 3 -T 20K@25 C -T J M J2 J F2 2 x 5AT F1 166HA J7 J15 T2 J LED 1 red (opt.) LED 2 green (opt) 22 C Thermostat (bus) Installer Thermostat (bus) 22 C 1 2 L white DC 4 white SIT 5 Modulating coil 9 1 J8 Get: MF Date: Ver: A Auth: Title: Nr.: GB R121 white puple blanc red white green green/yellow black black blue Air pressure switch dp A2 K1 A1 12 black F green/yellow blue black grey AirTemperature sensor on heater brown white yellow yellow brown Temperature sensors on heat exchanger white green yellow gasvalve blue Flue booster 1 N 2 L Thermical Fuse Motor relay K Thermical Fuse F Fan Motor M2 1F S2 S3 ON Micro switches S2 standard 1 to ON, and S3 to 1. Whem more heaters on one thermostat, each next heater must have its own number (2 til 8). Only in heater nr 1 S3 to 1, other heaters S3 to 0. S2 S3 ON ON / OFF setting R2 R3 4k7 4k7 Apliance recognition Motors without internal thermical relay Motoren zonder inerne Therische beveiliging 2V~ 50Hz, 1, N Motor relay Annex to Instructions TR Centrifugal Version GB 139d Page 14/41

15 7.3 3-Phase 400Vac Version L1 green/yellow blue brown C -T K@25 C 3 -T 20K@25 C -T J Installer 1 2 L1 L2 L M1 black black blue black J2 J F2 2 x 5AT F1 166HA J7 J15 T2 7 J J8 white puple blanc red white green Neutal Air pressure switch dp F A2 K1 A green/yellow blue black grey AirTemperature sensor on heater brown white yellow yellow brown Temperature sensors on heat exchanger white green yellow gasvalve blue green/yellow Flue booster L2 L3 1 N 2 L1 3 L2 L2 zwart L3 L3 zwart Thermical Fuse Motor relay K Thermical Fuse F U V W Fan Motor M2 3F S2 S3 ON Micro switches S2 standard 1 to ON, and S3 to 1. Whem more heaters on one thermostat, each next heater must have its own number (2 til 8). Only in heater nr 1 S3 to 1, other heaters S3 to 0. S2 S3 ON ON / OFF setting T Option for Rooftop: Vorstbeveiliging Frost protection Frostschützung Protection hors-gel 400V~ 50Hz, 3, N 22 C Thermostat (bus) 95 Shield Motor relay 13 white DC TR10 t/m 125 white SIT white Modulating coil AC white Hon. TR R2 R3 4k7 4k7 4 5 LED 1 red (opt.) LED 2 green (opt) Apliance recognition 22 C Get: MF Date: Ver: B Auth: Thermostat (bus) Title: Nr.: TR-C series 400V 3F GB R121 Annex to Instructions TR Centrifugal Version GB 139d Page 15/41

16 7.4 3-Phase 400Vac Version with soft starter L1 green/yellow blue brown C -T K@25 C 3 -T 20K@25 C -T J Installer M1 1 2 L1 L2 L Motor relay ST black black blue black J2 J F2 2 x 5AT F1 166HA J7 J15 T2 7 J J8 white puple blanc red white green Neutal Air pressure switch dp F A2 Q1 A green/yellow blue black grey AirTemperature sensor on heater brown white yellow yellow brown Temperature sensors on heat exchanger white green yellow gasvalve blue green/yellow Flue booster L2 L3 1 N 2 L1 L1 L2 L2 L3 L Thermical Fuse Motor Softstarter Thermical Fuse F U V W Fan Motor M2 3F S2 S3 ON Micro switches S2 standard 1 to ON, and S3 to 1. Whem more heaters on one thermostat, each next heater must have its own number (2 til 8). Only in heater nr 1 S3 to 1, other heaters S3 to 0. S2 S3 ON ON / OFF setting 400V~ 50Hz, 3, N 22 C Thermostat (bus) 95 Shield Q1.1 T Option for Rooftop: Vorstbeveiliging Frost protection Frostschützung Protection hors-gel 13 white white DC SIT TR10 t/m 125 white Modulating coil AC white Hon. TR R2 R3 4k7 4k7 4 5 LED 1 red (opt.) LED 2 green (opt) Apliance recognition 22 C Get: MF Date: Ver: A Auth: Thermostat (bus) Title: Nr.: TR-C series 400V 3F GB R131 Annex to Instructions TR Centrifugal Version GB 139d Page 16/41

17 8 Dimensions 8.1 TR24 & 28 Centrifugal / Rooftop TR24 C & 28 C Basic 4x M10 Top view TR24 C, 28 C & 31 C Back view TR24 C, 28 C & 31 C Side view TR24 C, 28 C & 31 C Option TR24 C, 28 C & 31 C 14 x M Air OUT flange TR24 C, 28 C & 31 C Front view TR24 C, 28 C & 31 C TR24 C, 28 C & 31 C basic Scale 1: D Ø 80 Flue outlet 205 D Ø 80 air inlet 2 Gas connection 3/4" Annex to Instructions TR Centrifugal Version GB 139d Page 17/41

18 8.1.2 TR24 & 28 A / C Fanbox Back view TR24 C, 28 C & 31 C Air intake flange TR24 C, 28 C & 31 C 6X M10 Top view TR24 C, 28 C & 31 C Side view TR24 C, 28 C & 31 C TR24 C, 28 C & 31 C 14 x M X M5 810 Air OUT flange TR24 C, 28 C & 31 C Front view TR24 C, 28 C & 31 C Side view top connection TR24 C, 28 C & 31 C TR24 C, 28 C & 31 C Fanbox Scale 1: Air D flue outlet Ø80 D air inlet Ø80 Air 665 Annex to Instructions TR Centrifugal Version GB 139d Page 18/41

19 8.1.3 TR24 R & TR28 R Rooftop Back view TR24 R, 28 R & 31 R X M5 Air intake flange TR24 R, 28 R & 31 R Top view TR24 R, 28 R & 31 R Side view TR24 R, 28 R & 31 R TR24 R, 28 R & 31 R Front view TR24 R, 28 R & 31 R x M5 780 Air OUT flange TR24 R, 28 R & 31 R TR24 R, 28 R & 31 R Rooftop Air TRC Rooftop Heater Heater frame inside 50 outside Roof construction Scale 1: Flue outlet terminal Ø80 included Annex to Instructions TR Centrifugal Version GB 139d Page 19/41

20 8.2 TR40 & 50 Centrifugal / Rooftop TR40 & 50 C Basic Top view TR40 & 50 C Back view TR40 & 50 C Side view TR40 & 50 C TR40 & 50 C Air OUT flange TR40 & 50 C Front view TR40 & 50 C x M10 D flue outlet O D air inlet O Gas connection 3/4" TR40 & 50 C basic Scale 1: Option x M Annex to Instructions TR Centrifugal Version GB 139d Page 20/41

21 8.2.2 TR40 & 50 A / C Fanbox Back view TR40 & 50 C Air intake flange TR40 & 50 C Top view TR40 & 50 C 1550 Side view TR40 & 50 C TR40 & 50 C Air OUT flange TR40 & 50 C Front view TR40 & 50 C Side view top connection TR40 & 50 C X M10 Air 14 x M Air TR40 & 50 C Fanbox Scale 1: X M D flue outlet Ø100 D air inlet Ø100 Annex to Instructions TR Centrifugal Version GB 139d Page 21/41

22 8.2.3 TR40 & 50 R Rooftop Back view TR40 & 50 R Top view TR40 & 50 R Side view TR40 & 50 R TR40 & 50 R Air Front view TR40 & 50 R TRC Rooftop Heater Heater frame inside 50 outside Roof construction TR40 & 50 R Rooftop Air intake flange TR40 & 50 R x M Air OUT flange TR40 & 50 R X M Scale 1: Flue outlet terminal Ø100 included Annex to Instructions TR Centrifugal Version GB 139d Page 22/41

23 8.3 TR60 & 80 Centrifugal / Rooftop TR60 C & 80 C Basic 605 Back view TR60 C & 80 C 705 4x M10 Top view TR60 C & 80 C Side view TR60 C & 80 C TR60 C &80 C X M Air OUT flange TR60 C & 80 C Front view TR60 C & 80 C D flue outlet Ø1 D air inlet Ø Gas connection 3/4" TR60 C & 80 C basic Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 23/41

24 8.3.2 TR60 & 80 A /C Fan box Back view TR60 C & 80 C Air intake flange TR60 C & 80 C Top view TR60 C & 80 C 1910 Side view TR60 C &80 C TR60 C & 80 C Air OUT flange TR60 C & 80 C Front view TR60 C & 80 C Side view top connection TR60 C & 80 C X M X M X M TR60 C & 80 C Fanbox Scale 1: D flue outlet Ø1 D air inlet Ø1 Annex to Instructions TR Centrifugal Version GB 139d Page 24/41

25 8.3.3 TR60 R & 80 R Rooftop X M5 Air intake flange TR60 R & 80 R Air OUT flange TR60 R & 80 R 1395 Back view TR60 R & 80 R x M5 Top view TR60 R & 80 R 1335 Side view TR60 R & 80 R Front view TR60 R & 80 R A SECTION A-A TRC Rooftop Heater Heater frame A inside outside 50 Roof construction TR60 R & 80 R TR60 R & 80 R Rooftop Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 25/41

26 8.4 TR100 Centrifugal / Rooftop TR100 C Basic X M5 Air OUT flange TR100 C Back view TR100 C x M10 Top view TR100 C 180 Side view TR100 C TR100 C Front view TR100 C D flue outlet O 1 D air inlet O 1 2 Gas connection 3/4" TR100 C basic Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 26/41

27 8.4.2 TR100 A / C Fan box X M5 Air intake flange TR100 C X M5 Air OUT flange TR100 C X M Back view TR100 C Top view TR100 C 1910 Side view TR100 C TR100 C Front view TR100 C Side view top connection TR100 C TR100 C Fanbox Scale 1:50 D flue outlet Ø1 D air inlet Ø1 395 Annex to Instructions TR Centrifugal Version GB 139d Page 27/41

28 8.4.3 TR100 R Rooftop X M5 Air intake flange TR100 R X M Air OUT flange TR100 R Back view TR100 R Top view TR100 R Side view TR100 R TR100 R Front view TR100 R 14 A SECTION A-A TRC Rooftop Heater Heater frame A inside outside 50 Roof construction Side view TR100 R Scale: 1 : scale 1 : 20 scale 1 : 20 TR100 R Rooftop Flue outlet terminal Ø1 included Annex to Instructions TR Centrifugal Version GB 139d Page 28/41

29 8.5 TR125 Centrifugal / Rooftop TR125 C Basic X M Air OUT flange TR125 C Back view TR125 C x M10 Top view TR125 C Side view TR125 C TR125 C Front view TR125 C D flue outlet Ø1 D air inlet Ø1 2 Gas connection 3/4" TR125 C basic Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 29/41

30 8.5.2 TR125 C Fanbox X M Air intake flange TR125 C Air OUT flange TR125 C Back view TR125 C 14X M5 6X M10 Top view TR125 C 1910 Side view TR125 C TR125 C Front view TR125 C Side view top connection TR125 C TR125 C Fanbox Scale 1: D flue outlet Ø1 D air inlet Ø1 Annex to Instructions TR Centrifugal Version GB 139d Page /41

31 8.5.3 TR125 R Rooftop X M Air intake flange TR125 R Air OUT flange TR125 R Top view TR125 R Back view TR125 R Side view TR125 R 14X M5 TR125 R Front view TR125 R 14 A SECTION A-A TRC Rooftop Heater Heater frame A inside outside 50 Roof construction TR125 R Rooftop Scale 1:50 10 Flue outlet terminal Ø1 included Annex to Instructions TR Centrifugal Version GB 139d Page 31/41

32 8.6 TR150 Centrifugal / Rooftop TR150 C Basic Back view TR150 C Top view TR150 C Side view TR150 C TR150 C Air OUT flange TR150 C scale 1 : 20 Front view TR150 C x M X M D flue outlet Ø1 D air inlet Ø1 2 Gas connection 3/4" TR150 C basic Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 32/41

33 8.6.2 TR150 C Fanbox Back view TR150 C Top view TR150 C Side view TR150 C TR150 C Air OUT flange TR150 C scale 1 : 20 Front view TR150 C x M10 16X M X M5 Air intake flange TR150 C scale 1 : Side view top connection TR150 C D flue outlet Ø1 D air inlet Ø1 Annex to Instructions TR Centrifugal Version GB 139d Page 33/41

34 8.6.3 TR150 R Rooftop 900 Back view TR150 R X M5 Air intake flange TR150 R scale 1 : Side view TR150 R Air OUT flange TR150 R scale 1 : 20 Front view TR150 R Top view TR150 R TR150 R X M A SECTION A-A TRC Rooftop Heater Heater frame A inside outside 50 Roof construction 13 Flue outlet terminal Ø1 included TR150 R Rooftop Scale 1:50 10 Annex to Instructions TR Centrifugal Version GB 139d Page 34/41

35 8.7 Construction frames Rooftop Frame TR24 R 50 R Rooftop Frame TR R Scale: 1 : 20 TRC Rooftop Heater inside 50 Heater frame Roof construction outside Annex to Instructions TR Centrifugal Version GB 139d Page 35/41

36 8.7.2 C Frame TR24 R 50 C / R DETAIL A A C Frame profile x Ø10mm , C Frame TR24, 28, 40, 50 C / R scale 1 : 20 Annex to Instructions TR Centrifugal Version GB 139d Page 36/41

37 8.7.3 Rooftop frame TR60 R-150 R TRC Rooftop Heater inside 50 Heater frame Roof construction outside Rooftop Frame TR60 C C scale: 1 : 20 Annex to Instructions TR Centrifugal Version GB 139d Page 37/41

38 8.7.4 C Frame TR C / R DETAIL A C - Profile 116 A , , C Frame TR60 t/m 150 C / R scale: 1 : 20 Annex to Instructions TR Centrifugal Version GB 139d Page 38/41

39 8.8 TR Rooftop + Air Outlet module TR24 R - 50 R Rooftop + Air outlet module TR24 R up to 50 R + Air outlet module Air in/out flange TR24 R up to 50 R + Air outlet module TRC Rooftop Heater inside Heater frame 50 outside Roof construction 10X M5 TR Rooftop Air outlet module TR24 R up to 50 R Rooftop + Air outlet module Side view TR24 R up to 50 R + Air outlet module Channel connection to install on side 900 Annex to Instructions TR Centrifugal Version GB 139d Page 39/41

40 8.8.2 TR60 R R Rooftop + Air outlet module Side view TR60 R up to 100 R + Air outlet module TR60 R up to 100 R + Air outlet module TR Rooftop Heater inside Heater frame 50 outside Roof construction 14X M5 Air in/out flange TR60 R up to 100 R + Air outlet module TR Rooftop Air outlet module Channel connection to install on side TR60 R up to 100 R Rooftop + Air outlet module Scale 1: Annex to Instructions TR Centrifugal Version GB 139d Page 40/41

41 8.8.3 TR125 R R Rooftop + Air outlet module Side view TR125 R & 150 R + Air outlet module 14X M5 TR125 R & 150 R + Air outlet module TR Rooftop Heater inside Heater frame 50 outside Roof construction X M5 900 Air in/out flange TR125 R & 150 R + Air outlet module TR Rooftop Air outlet module Channel connection to install on side TR125 R & 150 R Rooftop + Air outlet module Scale 1:28, Annex to Instructions TR Centrifugal Version GB 139d Page 41/41

TYPE TR Duct Ducting type

TYPE TR Duct Ducting type SUPPLEMENTARY INSTRUCTION BOOKLET GB140c AIR HEATER TYPE TR Duct Ducting type YOU MUST READ THIS DOCUMENT BEFORE COMMENCING INSTALLATION. THE USER MUST BE INSTRUCTED IN USING THE APPLIANCE. KEEP THIS DOCUMENT

More information

INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X

INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X GB 0g THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH THE HEATER FOR REFERENCE. Instruction

More information

TYPE XR10 60 THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH HEATER FOR REFERENCE.

TYPE XR10 60 THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH HEATER FOR REFERENCE. INSTRUCTION MANUAL PREMIX UNIT AIR HEATER TYPE XR0 60 THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH HEATER FOR REFERENCE. Instruction

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power. 27 Gas Dryer Technical Information MDG9700A * Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual

More information

BRISE. Heating and cooling from a single radiator

BRISE. Heating and cooling from a single radiator BRISE Heating and cooling from a single radiator T: + (0)5 6 5 F: + (0)5 6 5 jaga@jaga.co.uk Brise Wall-Mounted Dimensions Product code: BRIW Product code: BRBW B D C F 00 E 55 68 7 0 0 80 Ø 0 70 G 98

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 27 Domestic Dryer Technical Information MDE6700A*, MDG6700A* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power. 27 Electric Dryer Technical Information MDE9700A * Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service

More information

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION SALES REFERENCE DATE (Supersedes PF99-1) AUGUST, 2010 Portable Industrial Unit Blower Air Types SDRA and SDRA-RG SECTION SDRA

More information

48 50 UH UA PACKAGED ROOFTOP

48 50 UH UA PACKAGED ROOFTOP 48 50 UH UA PACKAGED ROOFTOP SPARE PARTS GENERAL VIEW FIGURE.1 50 UH-UA 045 FIGURE.2 48-50 UH 045 1 Suction and discharge line piping 2 Liquid line piping 3 Heaters 4 Outdoor fan assembly 5 Indoor fan

More information

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors. 4. Troubleshooting 4-1. Error items and diagnostic codes An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber F08-064 Operating Manual ESS0460-H119 PV Module Solar Soaking Chamber 12/19/2008 Thank you for your purchase. We are confident you will be completely satisfied with your new system. If for any reason you

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6. 4 4 6. -speed speed control. RIC ceiling model. RIW wall model 4. RW wall build-in model. grille from AS 6. ow-ho element _ Wall mounted model : Wall Wall mounted model RIF: RIse Free-standing Free-standing

More information

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6. 6 5. -speed speed control. IC ceiling model. IW wall model. W wall build-in model 5. grille from A 6. ow-h element 5 p. wall mounted model 6 ceiling-mounted model 7 Price list 8 Technical details 9 ptions

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Electric Dryer Technical Information CDG4205A* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

CLOTHES DRYER Technical Information

CLOTHES DRYER Technical Information CLOTHES DRYER Technical Information Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual (DV456*,DV422*,DV400*)

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

Installation and Operating Manual Drying Cabinet

Installation and Operating Manual Drying Cabinet Drying Cabinet TS-4175 WW CONTENTS THIS USER MANUAL & DATA PLATE DETAILS Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS Page 8 MAINTENANCE INSTRUCTIONS

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector. ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP AXIAL HEATER TROUBLE SHOOTING GUIDE Page 1 July 2009 Table of Contents Frequently Asked Questions... 3 Axial Heater CONTROL (Siemens LME69) Troubleshooting Chart... 4 Axial Heater BURNER Troubleshooting

More information

Brivis Inverter Icebox

Brivis Inverter Icebox Brivis Inverter Icebox R410A INSTALLATION INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & USING THIS PRODUCT Bonus offer when you register your product online brivis.com.au Table

More information

Swedish design and manufacture since 1967

Swedish design and manufacture since 1967 Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

CLOTHES DRYER Technical Information

CLOTHES DRYER Technical Information CLOTHES DRYER Technical Information IMPORTANT SAFETY NOTICE For Technicians only This service data sheet is intended for use by persons having electrical, electronic, and mechanical experience and knowledge

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

BK17 Heater. Read all instructions before using the heater. Contents

BK17 Heater. Read all instructions before using the heater. Contents Read all instructions before using the heater Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 a) Power Specifications... 4 3) Receiving... 4 4) Safety... 5 a) Power connections...

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

PREEVA air handling unit

PREEVA air handling unit APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

MOUNTING INSTRUCTIONS ZANTINGH BURNERINSTALLATION

MOUNTING INSTRUCTIONS ZANTINGH BURNERINSTALLATION MOUNTING INSTRUCTIONS ZANTINGH BURNERINSTALLATION Op al onze leveringen en diensten aan Nederlandse (contracts)partijen zijn de FME-CWM voorwaarden van toepassing (gedeponeerd bij de Kamer van Koophandel

More information

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

The CAB & DAB Air Curtains

The CAB & DAB Air Curtains The CAB & DAB Air Curtains Frequently Asked Questions General Positioning Page 2 Electrical & Connection Page 4 Electric Heated Page 5 Electronic door triggered shutdown feature (Electric) Page 5 Electronic

More information

Installation and maintenance manual

Installation and maintenance manual Installation and maintenance manual Warm air heater WS/WO (Copy of the original version) Wolf GmbH D-84048 Mainburg Postfach 1380 Telefon +498751/74-0 Telefax +498751/741600 Internet: www.wolf-heiztechnik.de

More information

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4 Installation Operation Maintenance Ductable water unit FWD 08-12 - 20-30 - 45 General Information Foreword These installation, operation and maintenance instructions are given as a guide to good practice

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Electric Dryer Technical Information CDE4205A* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing

More information

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21 Part No. DOC 38 Rev. 02 January 2007 SUPPLEMENTARY INSTALLATION and SERVICING INSTRUCTIONS Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21 For use with Kerosene only

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for

More information

Installation instructions for Plenum-mounted add-on electric heaters

Installation instructions for Plenum-mounted add-on electric heaters Installation instructions for Plenum-mounted add-on electric heaters Aug. 2008 Version 4 THESE INSTALLATION INSTRUCTIONS COVER: MODEL T-4 to T-30 (4 Kw to 30 Kw) GENERAL NOTES - Please refer to CSA Standard

More information

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h KOG LN Low Noise Chilled Water Cassettes 09, 12 & 18 1.70 to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

GAS AIR HEATER RANGE

GAS AIR HEATER RANGE GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

LHS PREMIUM LHS SYSTEM

LHS PREMIUM LHS SYSTEM GB LHS PREMIUM LHS SYSTEM Leister Process Technologies Galileo-Strasse 10 CH-6056 Kaegiswil/Switzerland Tel. +41-41662 74 74 Fax +41-41662 74 16 www.leister.com sales@leister.com OPERATING INSTRUCTIONS

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EASQ 3017 For Board Use Only Result Date Int Result Date Int ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ

More information

FF3 INDUSTRIAL ELECTRIC FAN HEATER PRODUCT MANUAL GENERAL SAFETY. Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug

FF3 INDUSTRIAL ELECTRIC FAN HEATER PRODUCT MANUAL GENERAL SAFETY. Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug Also available:- Ductable 3 Phase Fan Heaters:- FF13 415v - 16A 415v 3PH + Earth Supply (No Neutral required.) FF29 415v - 32A 415v 3PH + Earth Supply (No Neutral required.) FF42 415v - 63A 415v 3PH +

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc. SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers

More information

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since HETING HETING EQUIPMENT FOR GRICULTURL ND INDUSTRIL PPLICTIONS since 1967 DIRECT GS-FIRED IR HETER The air heater agriterm was developed for livestock buildings. It is entirely made of stainless steel

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC USER MANUAL Version 1.0 Doc. T744.01_EN (TEMP) TVHET916A07BK IMPORTANT READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions

More information

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

Products and prices. CLIMATE TECHNOLOGY feels better, works better. Products and prices CLIMATE TECHNOLOGY feels better, works better. www.markclimate.com Long-term leaders in climate management Get to know the specialist in the Netherlands in the field of air heating,

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

40E ELECTRIC FAN HEATER

40E ELECTRIC FAN HEATER 40E ELECTRIC FAN HEATER PRODUCT MANUAL IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM- BLING, STARTING OR SERVICING THE HEATER. IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY. KEEP THIS MANUAL

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Concealed ceiling unit with medium ESP

Concealed ceiling unit with medium ESP FXSQ-A Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market Slimmest unit in class, only 245mm (3mm built-in height) and therefore narrow ceiling

More information

Locally Controlled Bug Killers. Read all instructions before using the bug killer. Contents

Locally Controlled Bug Killers. Read all instructions before using the bug killer. Contents Read all instructions before using the bug killer Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 a) BK10L... 5 b) BK15L... 5 c) BK20L... 5 3) Receiving... 5 4) Safety... 6 a) Power

More information

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Do Žlábku 733, 514 01 Jilemnice Subject: MTP (MTPAL) Technical Documentation Page 1 of 13 MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Table of Contents: Page: 2 Warranty Certificate 3 Quality and Completeness

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL COOLING 1. DESCRIPTION On aircraft serials 183 and subsequent, an optional air condition system is available. This section contains the maintenance practices pertinent to this system. Cabin ventilation

More information

TopMaster Air Handling unit. Installation instructions

TopMaster Air Handling unit. Installation instructions Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into

More information

Installer manual ELK 213 Immersion heater

Installer manual ELK 213 Immersion heater Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan Installation plan Washing machine PW 5064 MOPSTAR 60 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced

More information

Installation Instructions

Installation Instructions 53DS --- 900 --- --- --- 092 Duct---Free Systems Accessory Power Ventilation Kit for In --- Ceiling Cassette Fan Coil Units Size 018 --- 036 Installation Instructions NOTE: Read and become familiar with

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONSTANT VOLUME LINEAR CEILING DIFFUSER 12 CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual. LEIHDC70SC - LEIHDC70BB LEIHDC70BC Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...9 2 RECOMMENDATIONS

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL COMPACTAIR KVCK KVHA / KVHK TABLE OF CONTENTS POINTS TO KEEP IN MIND PAGE 2 DATA PAGE FOR UNIT COMMISSIONING PAGE 3 1.- GENERAL CHARACTERISTICS PAGE 1.1.- PHYSICAL DATA

More information