AAF Herman Nelson. Classmate Conventional Unit Ventilators. AH AV Vintage C
|
|
- Malcolm Gilmore
- 5 years ago
- Views:
Transcription
1 Replacement Parts List No Revision R 0/206 AAF Herman Nelson Classmate Conventional Unit Ventilators AH AV Vintage C UAHB, UAHF, UAHR, UAHV UAVB, UAVR, UAVS, UAVV 07-5 Design C (3) Last Manufacture: 200 To find your Daikin Applied parts distributor, call or visit
2 Contents About the Model Number Changes...2 Parts List Revision History Nomenclature Serial Number Model Number AH, UAHB, UAHF, UAHR, UAHV Model Number AV, UAVB, UAVR, UAVS, UAVV Adapter Back Kits... External Cabinetry AV Cabinet AH Cabinet... 3 Fan Section- Motor and Fan Components... 4 Electric Heat Electric Heat Elements... 5 Electric Controls... 5 Coil Section Damper Section Drain Pan, and Face & Bypass Damper Components OA & Room Air Damper Components Hydronic Valves and Actuators... 2 Controls PC Board- Main Controllers MicroTech M Controls By Others Fuses, Relays, Switches and Time Clock Field Installed Accessories Filters Critical Parts List AH , UAHB, UAHF, UAHR, UUAHV CPL AV , UAVB, UAVR, UAVS, UAVV CPL2 About the Model Number Changes In 2005 the model numbering nomenclature for the Conventional Unit Ventilators changed: The AH "C" Vintage unit is now the UAHB Design "C" unit. The AV"C" Vintage unit is now the UAVB Design "C" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 2
3 Parts List Revision History Revision Date Description A 08//97 Page 6; AV Top Discharge Grille (Bubble #2) part numbers corrected (all sizes). Page 4; AH Discharge Air Grille (Bubble #2) part numbers corrected (all sizes). B /3/97 Page 29; AV/AH Damper Section; Actuator - OA with Linkage (Bubble #) pn was 4EZB9324. AV/AH Damper Section; Actuator - FBP with Linkage (Bubble #2) pn was 4EZB9324. C 07/98 Page 39; corrected item #0 on 6 fan, 460V. D 05/99 Page 27 - Added description and part number for Auxillary Drain Pans. E 0/99 Added new Page 4 - AV Adapter Back Kits. This resulted in the re-numbering of all later pages. Page 4 - Added footnote for Filter Stop (Bub.# 8). Page 20 - Corrected part number for Bar Grille (Bub.#) for 6-fan units. Page 22 - Added Blower Assembly. Added column and information for Unit Size 008. Page 23 - Added Bub.# 0 to diagram. Added Motor Gasket part number and description. Page 29 - Updated pn's for Damper Stop, Rear (Bub. 7) on all sizes.added Seal Strip Gasket pn's, descriptions & footnote. Page 33 - Updated; pn's for Damper - RA (Bub.02) all sizes. Info for Shafts (Bub. & 2). Page 43 - Updated info& added foonote for Low Temp. T'Stat, DE Coil (Bub. 34). Added pn & description for Freezestat Clip. Page 48 - Updated pn for Transformer, Motor Speed (Bub.# 5) for 208V, 230V & 265V units. Page 50 - Updated information and added footnote for Fan Relay (Bub.# 74). F /99 Page 43 - Added Sampling Chamber Gasket and Sampling Chamber Screw. G 09/00 Page 4-3/Fan units; 2.875"Top only pn now , added new 28" Top Only # /Fan units; 2.875"Top Only pn is now , added new 28" Top Only pn /Fan units; 2.875"Top Only pn is now , added new 28" Top Only pn /Fan units; 2.875"Top Only pn is now , added new 28" Top Only pn Page 6 - Tinnerman pn changed from 4NKE8447 to 4NKE7968. Page 8 - Bub #2 pn changed from GC0748 to GC045. Page 0 - Bub #4 part numbers ended in 0, now end in 02. Page 6 - Bub #2 pn changed from GC0748 to GC045. Page 40 - Bub #; 265/460/575V TB pn 4ECA8878 changed to , (9 instances). Page 4- Bub #; 265/460/575V TB pn 4ECA8878 changed to , (0 instances). Page 44 - Bub #53; pn 4EPC9056 changed to Page 48 - Bub #52; pn 4EPC9056 changed to H 08/0 Page 2-'Attaching Parts' screw pn was incorrect, the correct pn is 4SAD3732. I 0/02 Page 44 - Bub #66- Description changed from "Plug & Receptacle Combo to just 'Plug'. J 02/05 Page 22 - Fan Wheel (Plastic) is not included in the Blower Assembly. K 05/05 Page 0 - Bub 37 discharge plenum pn's changed as follows; 4 fan pn changed from to , 5 fan pn changed from to , 6 fan pn changed from to L 05/ Reformat to CSIV. Changed title page to reflect new code sheet title-"uahx, UAVX". Page 2 Added Model Number Note. Pages 4-9 Add code sheets. Add CPL Page. M 0/2 Title Page & footer- Change title to AH, UAHB, UAHF, UAHR, UAHV and AV, UAVB, UAVR, UAVS, UAVV. N 09/3 Relinked all drawings. Numerous changes were made. Pages Deleted- Dataplate Location, Sheet metal deleted from External Cabinetry, Touch-up paint, Electrical Data & External Static Pressure Chart, and Diagrams. Delete all Unit Size 00. Title Page - Update to new format. Unit size started from 00 changed to 003. Page 2- Change Table of Contents to Contents and repagenate. Pages 5-6 Model Numbers were combined from Code -23 for AV and AH units. Page 7- AV Codes continued from Continued on the next page. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN (763) UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 3
4 Parts List Revision History Revision Date Description N 09/3 Page 8- AH Codes continued from (Cont.) Page 4- Add coils for AH unit size 008. Pages 9-9- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Page 20- Field Installed Accessories- Moved filters here. CPL- Added AH unit size 008. deleted AV units from this page CPL2- Added page for AV units. P 09/3 Numerous changes made. Size 008 added for all AH/UAHX units Title Page - Change model sizes for UAHX and UAVX units. Pages 5-7 Code was split into AH units and Av units. Pages 5-7 Code for AH/UAHX units. Page 8-0 Code for AV/UAVX units. Pages 9-9- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Pages 6-8 Add Pages for coil section. Page 24- Field Installed Accessories- Moved filters here. CPL- Added AH unit size 008. Deleted AV units from this page CPL2- Added page for AV units. Q 2/5 Rebrand Daikin format. Add unit size 07 to 00/003; 0 to 004; 3 to 005; 5 to 006; 20 to 008. Page 2- Delete unit size and detail A-A. Page 3- Delete unit size. Page 4- Add unit sizes 00, 03, 05. Change motor /4 HP p/n to Change coupling p/n GCA50005A to GC502C for /4HP motor. Change coupling p/n GCA50005A to GC86B for /3 & /2HP motors CPL, CPL2- Rebrand Daikin format. CPL2- Change motor /4 HP p/n to R 0/6 Page 2- Change 2-way valve from " to 3/4". UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 4
5 Plant Identification AUB = Auburn U= Unit AUB U Serial Number (build sequence) Week of Manufacture Year of Manufacture 08= = = 200 etc. Model Number AH, UAHB, UAHF, UAHR, UAHV UAHB 003 C 0 F HWP 2 WY W Y C Y YY HC3 2M A C3 Code M7 B LY ST S W 2 BT A SFB YY T A Y Code Code 0= Unit Type AH= Ceiling, Unit Ventilator UAHB= Ceiling, Face & Base, Reheat, Unit Ventilator UAHF= Ceiling, Face & Base, Unit Ventilator UAHR= Ceiling, w/valve Control, Reheat, Unit Ventilator UAHV= Ceiling, w/valve Control, Unit Ventilator Nomenclature Serial Number Code 07= MicroTech Occupied/Unoccupied Controls = Day-Night Changeover Relay, 24V 2= Day-Night Changeover Relay, 5V 3= Time Clock & Holiday Switch 5= None Y= Controls By Others Code 02= Unit Size 00= Series CFM (AH only) 003= Series CFM (H07, S07) 004= Series CFM (H0, S0) 005= Series CFM (H3, S3) 006= Series CFM (H5, S5) 008= Series CFM (H20, S20) Code 03= Vintage/Design C= Vintage C (example: AH003C) 3= Design C (example: UAHV3H07) Code 04= Unit Voltage 0= 230/60/ 27= 460/60/3 03= 208/60/ 29= 230/60/3 = 5/60/ 37=575/60/3 2= 208/60/3 47= 265/60/ Code 05= Damper F= Face & Bypass N= None Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory Installed HWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory Installed BCE= Barber-Colman Electric Factory Installed MN2= MicroTech Network-ASHRAE Cycle II MN3= MicroTech Network-ASHRAE Cycle III MP2= MicroTech Open Protocol-ASHRAE Cycle II MP3= MicroTech Open Protocol-ASHRAE Cycle III MA2= MicroTech Stand-Alone-ASHRAE Cycle II MA3= MicroTech Stand-Alone-ASHRAE Cycle III MM2= MicroTech Stand-Alone Master-ASHRAE Cycle II MM3= MicroTech Stand-Alone Master-ASHRAE Cycle III MS2= MicroTech Stand-Alone Slave-ASHRAE Cycle II MS3= MicroTech Stand-Alone Slave-ASHRAE Cycle III FLE= Controls By Others- Field Installed- Electric FLP= Controls By Others- Field Installed- Pneumatic Code 08= MicroTech Room Temperature Sensors UY= Unit Mounted WY= Wall Mounted w/o TC WT= Wall Mounted w/ TC CY= Wall Mounted w/ Comm Port w/o TC CT= Wall Mounted w/ Comm Port w/ TC YY= Controls By Others Code 09= MicroTech Tenant Override W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code 0= MT Room Temperature Setpoint Adj. ± 3 F W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code = MT Ventilation Relay A= Ventilation Lockout- 24V B= Ventilation Lockout- 5V C= Ventilation Interlock, Maximum- 24V D= Ventilation Interlock, Maximum- 5V N= None Y= Controls By Others Code 2= Shutdown Relay Code 3= Always YY Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 5
6 Code 4= Heating Coil Type & Capacity Hot Water/Chilled Water- 2 Pipe HC3= 3-Row HC4= 4-Row HC5= 5-Row Hot Water HW= -Row HW2= 2-Row HW3= 3-Row Steam- Same End Drain SSL= Low Capacity SSH= High Capacity Electric Heat- Open Wire Element EW= Element 6EW= 6 Element 2EW= 2 Element 7EW= 7 Element 3EW= 3 Element 8EW= 8 Element 4EW= 4 Element 9EW= 9 Element 5EW= 5 Element Electric Heat- Sheathed Element ES= Element 6ES= 6 Element 2ES= 2 Element 7ES= 7 Element 3ES= 3 Element 8ES= 8 Element 4ES= 4 Element 9ES= 9 Element 5ES= 5 Element NNN= None Nomenclature Model Number- AH, UAHB, UAHF, UAHR, UAHV Code 5= MicroTech Heating Coil Valve Hot Water or Steam, 2-Way Modulating Valve 2M= ½"- #2 Port,.3CV 2M2= ½"- #3 Port, 2.2CV 2M4= ½"- #4 Port, 3.6CV 2M5= ¾"- #5 Port, 5.0CV 2M6= ¾"- #6 Port, 6.2CV Steam, 2-Way Modulating Valve 2M8= "- #7 Port, 8.2CV 2M9= "- #8 Port,.0CV Hot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (" for ST; ¾" for HW) 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Codes 8= Chilled Water Coil Valve 2-Way Modulating Valve 2M2= ½", 2.0CV 2M4= ½", 4.0CV 2M7= ¾", 6.8CV 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (¾") 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 9= Chilled Water Piping Package A= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve & Flow Valve Code 20= Coil Connection Locations LY= Left Hand, Single Coil RY= Right Hand, Single Coil LR= Left Hand Cooling- Right Hand Heating RL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand Heating RR= Right Hand Cooling- Right Hand Heating Code 2= Drain Pan = Standard 2= Stainless Steel Code 22= Exterior Panels ST= Standard Code 23= Access Panels S= Standard U= Unhinged Code 24= Paint Color of Unit Panels A= Putty Beige E= Soft Grey B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White Code 6= Hot Water Piping Package A=Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 7= Cooling Coil Chilled Water C3= 3-Row C4= 4-Row C5= 5-Row Direct Expansion AC= Split System Air Conditioner HP= Split System Heat Pump NN= None Code 25= External Static Pressure = 0-.20" 2=.2-.45"(.2-.50" for Unit Size 008) Code 26= Fan Shaft & Motor Bearing = Oilable Sleeve 2= Permanently Lubricated Code 27= Air Inlet Location BT= Bottom Grille, RA, Top Duct Collar OA BR= Bottom Grille, RA, Rear Duct Collar OA BN= Bottom Grille RA, No OA RT= Rear Duct Collar RA, Top Duct Collar OA RR= Rear Duct Collar RA, Rear Duct Collar OA RN= Rear Duct Collar RA, No OA Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 6
7 Code 28= Outdoor Air Damper A= Standard B= Standard w/setscrew Lock C= Cold Weather Insulated D= Cold Weather Insulated w/ Setscrew Lock R= None, Recirculation Unit Nomenclature Model Number- AH, UAHB, UAHF, UAHR, UAHV Code 29= Cabinet Mounting & Discharge Air Arrangement SFB= Standard, Front Discharge, Barsock Grille SFC= Standard, Front Discharge, Duct Collar SFV= Front Barsock Discharge Grille w/side Defl. Vanes PFD= Plenum, Front Discharge, Double Deflection Grille PBD= Plenum, Bottom Discharge, Double Deflection Grille PFC= Plenum, Front Discharge, Duct Collar PFB= Plenum, Front Discharge, Barsock Grille Code 32= Fiter Indicator = Dirty Filter Light Code 33= Return Air Staic Balance = Included Code 34= Auxiliary Drain Pan A= Included Code 35= Service Switch = Included Code 30= Always YY Code 36= Future Use Only- Always Y Codes 3= Filter Type P= Permanent Mesh M= Renewable Media w/metal Frame R= Roll Filter T= Throwaway UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 7
8 Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV UAVV 003 C 0 F HWP 2 WY W U C Y YY HC3 2M A C3 Code M7 B LY ST S A W D FR A FTD YY P A A A Y Code Code 0= Unit Type AV= Floor, Unit Ventilator UAVB= Floor, Face & Base, Reheat, Unit Ventilator UAVR= Floor, w/valve Control, Reheat, Unit Ventilator UAVS= Floor, Face & Base, Unit Ventilator UAVV= Floor, w/valve Control, Unit Ventilator Code 02= Unit Size 00= Series CFM (AV only) 003= Series CFM (H07, S07) 004= Series CFM (H0, S0) 005= Series CFM (H3, S3) 006= Series CFM (H5, S5) Code 03= Vintage/Design C= Vintage C (example: AV003C) 3= Design C (example: UAVV3H07) Code 04= Unit Voltage 0= 230/60/ 27= 460/60/3 03= 208/60/ 29= 230/60/3 = 5/60/ 37=575/60/3 2= 208/60/3 47= 265/60/ Code 05= Damper F= Face & Bypass N= None Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory Installed HWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory Installed BCE= Barber-Colman Electric Factory Installed MN2= MicroTech Network-ASHRAE Cycle II MN3= MicroTech Network-ASHRAE Cycle III MP2= MicroTech Open Protocol-ASHRAE Cycle II MP3= MicroTech Open Protocol-ASHRAE Cycle III MA2= MicroTech Stand-Alone-ASHRAE Cycle II MA3= MicroTech Stand-Alone-ASHRAE Cycle III MM2= MicroTech Stand-Alone Master-ASHRAE Cycle II MM3= MicroTech Stand-Alone Master-ASHRAE Cycle III MS2= MicroTech Stand-Alone Slave-ASHRAE Cycle II MS3= MicroTech Stand-Alone Slave-ASHRAE Cycle III FLE= Controls By Others- Field Installed- Electric FLP= Controls By Others- Field Installed- Pneumatic Code 07= MicroTech Occupied/Unoccupied Controls = Day-Night Changeover Relay, 24V 2= Day-Night Changeover Relay, 5V 3= Time Clock & Holiday Switch 5= None Y= Controls By Others Code 08= MicroTech Room Temperature Sensors UY= Unit Mounted WY= Wall Mounted w/o TC WT= Wall Mounted w/ TC CY= Wall Mounted w/ Comm Port w/o TC CT= Wall Mounted w/ Comm Port w/ TC YY= Controls By Others Code 09= MicroTech Tenant Override U= Unit Mounted W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code 0= MT Room Temperature Setpoint Adj. ± 3 F U= Unit Mounted W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code = MT Ventilation Relay A= Ventilation Lockout- 24V B= Ventilation Lockout- 5V C= Ventilation Interlock, Maximum- 24V D= Ventilation Interlock, Maximum- 5V N= None Y= Controls By Others Code 2= Shutdown Relay Code 3= Always YY Code 4= Heating Coil Type & Capacity Hot Water/Chilled Water- 2 Pipe HC3= 3-Row HC4= 4-Row HC5= 5-Row Hot Water HW= -Row HW2= 2-Row HW3= 3-Row Steam- Same End Drain SSL= Low Capacity SSH= High Capacity Steam- Opposite End Drain SDL= Low Capacity SDH= High Capacity Electric Heat- Open Wire Element EW= Element 6EW= 6 Element 2EW= 2 Element 7EW= 7 Element 3EW= 3 Element 8EW= 8 Element 4EW= 4 Element 9EW= 9 Element 5EW= 5 Element Electric Heat- Sheathed Element ES= Element 6ES= 6 Element 2ES= 2 Element 7ES= 7 Element 3ES= 3 Element 8ES= 8 Element 4ES= 4 Element 9ES= 9 Element 5ES= 5 Element NNN= None Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 8
9 Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV Code 5= MicroTech Heating Coil Valve Hot Water or Steam, 2-Way Modulating Valve 2M= ½"- #2 Port,.3CV 2M2= ½"- #3 Port, 2.2CV 2M4= ½"- #4 Port, 3.6CV 2M5= ¾"- #5 Port, 5.0CV 2M6= ¾"- #6 Port, 6.2CV Steam, 2-Way Modulating Valve 2M8= "- #7 Port, 8.2CV 2M9= "- #8 Port,.0CV Hot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (" for ST; ¾" for HW) 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 6= Hot Water Piping Package A=Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 7= Cooling Coil Chilled Water C3= 3-Row C4= 4-Row C5= 5-Row Direct Expansion AC= Split System Air Conditioner HP= Split System Heat Pump NN= None Codes 8= Chilled Water Coil Valve 2-Way Modulating Valve 2M2= ½", 2.0CV 2M4= ½", 4.0CV 2M7= ¾", 6.8CV 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (¾") 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 9= Chilled Water Piping Package A= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 20= Coil Connection Locations LY= Left Hand, Single Coil RY= Right Hand, Single Coil LR= Left Hand Cooling- Right Hand Heating RL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand Heating RR= Right Hand Cooling- Right Hand Heating Code 22= Exterior Panels ST= Standard Code 23= Access Panels S= Standard K= Key Lock Code 24= Paint Color of Unit Panels A= Putty Beige E= Soft Grey B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White Code 25= Paint Color of Top A= Putty Beige H= Textured Charcoal Bronze B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White E= Soft Grey Code 26= Unit Depth/Adapter Back A= 6-5/8" Open Pipe Passage B= 6-5/8" Closed Pipe Tunnel C= 6-5/8" w/ 9" Vertical Finished Back D= 2-7/8" Adapter Back Pipe Passage E= 2-7/8" Full Adapter Back Closed Pipe Tunnel F= 2-7/8" Open Adapter Back K= 28" Total, Using -3/8" Top Extension L= 28" Total Closed Pipe Tunnel Full Adapter Back M= 2-7/8" Energy Recovery System Adapter Back Code 27= Air Inlet Location FR= Front RA, Rear OA FB= Front RA, Bottom Duct Collar OA FN= Front RA, No OA FT= Front RA, Top Duct Collar OA DR= Draft Stop RA, Rear OA DB= Draft Stop RA, Bottom Duct Collar OA DN= Draft Stop RA, No OA DT= Draft Stop RA, Top Duct Collar OA Code 28= Outdoor Air Damper A= Standard B= Standard w/setscrew Lock C= Cold Weather Insulated D= Cold Weather Insulated w/ Setscrew Lock R= None, Recirculation Unit Code 29= Cabinet Mounting & Discharge Air Arrangement Wall Mounted WFD= w/plenum Front Discharge, Double Deflection Grille WTB= Top Discharge, Barsock Grille Floor Mounted FTB= Top Discharge, Barsock Grille w/rh Top Access Door FDC= Top Duct Collar w/rh Top Access Door FTV= Top Grille, Side Deflection Vanes w/rh Top Access Door FTD= Top Barsock Grille w/rh & LH Top Access Doors FVD= Top Grille, Side Deflection Vanes w/lh Top Access Door FDD= Top Duct Collar w/rh & LH Top Access Doors Inverted Wall Mounted MFD= w/plenum Front Discharge, Double Deflection Grille MBB= Bottom Discharge, Bar Stock Grille Code 2= Drain Pan = Standard 2= Stainless Steel Code 30= Always YY UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 9
10 Codes 3= Filter Type P= Permanent Mesh M= Renewable Media w/metal Frame T= Throwaway Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV Code 32= Thru Piping in Upper Pipe Tunnel A= (2) 7/8" Uninsulated Straight Pipe B= () -5/8" Insulated Pipe- Supply C= () -5/8" Insulated Pipe- Return D= (2) -5/8" Insulated Pipe E= () 2-/8" Insulated Pipe- Supply F= () 2-/8" Insulated Pipe- Return G= (2) 2-/8" Insulated Pipe H= () -5/8" Supply & () 2-/8" Return Insulated J= () 2-/8" Supply & () -5/8" Return Insulated Code 33= Thru Piping in Lower Pipe Tunnel A= () -5/8" Insulated- Supply B= () -5/8" Insulated- Return C= (2) 2-/8" Uninsulated Code 34= Auxiliary Drain Pan A= Included Code 35= Service Switch = Included Code 36= Always Y UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 0
11 Unit Size /07 Adapter Back Kits 3 Fan Units Part Part Description Number Closed Tunnel Finished Back Top Only Full Open Tunnel Full Closed Tunnel , 2 Step Down, Full Open , 2 Step Down, Full Closed Full Closed Tunnel " Top Only Unit Size 004/0 4 Fan Units Part Part Description Number Closed Tunnel Finished Back Top Only Full Open Tunnel Full Closed Tunnel , 2 Step Down, Full Open , 2 Step Down, Full Closed Full Closed Tunnel " Top Only Unit Size 005/3 5 Fan Units Part Part Description Number Closed Tunnel Finished Back Top Only Full Open Tunnel Full Closed Tunnel , 2 Step Down, Full Open , 2 Step Down, Full Closed Full Closed Tunnel " Top Only Unit Size 006/5 6 Fan Units Part Part Description Number Closed Tunnel Finished Back Top Only Full Open Tunnel Full Closed Tunnel , 2 Step Down, Full Open , 2 Step Down, Full Closed Full Closed Tunnel " Top Only UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page
12 External Cabinetry AV Cabinet 2 See Cabinet/Chassis components 2" "L" 24.80" 2" Ref Description Part Number Qty. No. Front Panel, End 2 2 Front Panel, Center N/S Cabinet/Chassis components Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 2
13 External Cabinetry AH Cabinet FRONT PANEL 2 Ref Description Part Number Qty. Bottom Rear Access Panel 2 Bottom Front Access Panel N/S Rear Panel Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 3
14 Fan Section Motor and Fan Unit Sizes Components Ref. Description Part Unit Size/Qty. No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Shaft GC8504 N/S Shaft GC8505 N/S Shaft GC8506 N/S Shaft GC06 N/S Wheel, Plastic N/S Wheel, Metal GF0 4 N/S Sleeve Bearing AV units 4ACE2556A N/S Ball Bearing AH units 4AAE7976 N/S Coupling, /4 HP Motor GC502C N/S Coupling /3 HP & /2 HP Motor GC86B N/S Housing AV units N/S Housing AH units GCF532 4 N/S Gasket AV units N/S Motor- AV Unit /4 HP, Sleeve Bearing until 4/ /4 HP, Sleeve Bearing 4/02 & later N/S Motor- AH Unit /4 HP, Ball Bearing /3 HP, Ball Bearing /2 HP, Ball Bearing LADQ5949 N/S = Not shown on diagram. Motors are 5/60/ regardless of unit voltage. It is important that the correct X transformer be installed (see Code 5 for voltage). NOTE: Do not mix plastic & aluminum wheels on same unit. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 4
15 Electric Heat Electric Heat Elements Description 00/003/07 004/0 005/3 006/5 008/20 3 Fan 4 Fan 5 Fan 6 Fan 4 Fan 500/750 CFM 000 CFM 250 CFM 500 CFM 2000 CFM ELECTRIC HEAT ELEMENT (HTR /9) Open Wire Element, 208V Element, 230V Element, 265V Element, 460V Element, 575V Sheathed Part Number/Unit Size Element, 208V 4EHH8887 4EHH8888 4EHH8889 4EHH8890 N/A Element, 230V 4EHH889 4EHH8892 4EHH8893 4EHH8894 N/A Element, 265V N/A Element, 460V 4EHH8895 4EHH8896 4EHH8897 4EHH8898 N/A Element, 575V 4EHH8899 4EHH8900 4EHH890 4EHH8902 N/A Electric Controls Sch. Description Part Unit Size Sym. Number 00/003/07 004/0 005/3 006/5 008/20 F2A/F6C Fuse, 30A 208/230/265V 4EHG F2A/F6C Fuse, 60A 208/230/265V 4EHG AF Airflow Switch 4EMB825 DF Deadfront Switch 4EAL2427 OH Thermostat, Overheat AV/AH 4ELN7697 OH2 Thermostat, Overheat AH 4ELN5523 UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 5
16 Coils Section Channel Mount Diagram Screw Part Number 4SBA4206 Coil Support Channel Part Number Part Number Description 00 3 Fan 500 CFM 36" Long 003/07 3 Fan 750 CFM 36" Long 004/0 4 Fan 000 CFM 48" Long 005/3 5 Fan 250 CFM 60" Long 006/008/5/20 6 Fan 500/2000 CFM 72" Long Hot Water Hot Water, Low Capacity, -row N/A Hot Water, Med. Capacity, 2-row N/A Chilled Water / Hot Water* Chilled Water, 3-row N/A Chilled Water, 4-row N/A Chilled Water, 5-row N/A Steam** Steam,Low Capacity, -row N/A GRF03 GRF04 GRF05 GRF06 Steam, High Capacity, 2-row N/A GRF000 GRF00 GRF002 GRF003 Check Valve N/A Direct Expansion Direct Expansion Coil Direct Expansion Coil, Heat Pump N/A Expansion Valve Expansion Valve 4FDV Check Valve (heat pump coil) N/A N/A = Not Applicable * Reference Instructions - Hot Water Coil Mounting p/n ** Reference Instructions - Cold Water Coil Mounting p/n UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 6
17 AV/AH Coil Section Coil Mount, Chilled Water Diagram (Ref ) See Note 5 See Note 6 See Note 6 See Note 5 AIR FLOW AIR FLOW See Note 7 See Note 4 See Note 7 See Note 4 LEFT-HAND APPLICATION RIGHT-HAND APPLICATION DETAIL "A" 2 9 Plug from Coil Ref. Note NOTES:. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A". 2. Return label is placed always opposite drain connections. Supply label is placed always at center connection. 3. Braze Item with drain at bottom of connection. 4. Drain connection floor unit or wall unit. 5. Drain connection ceiling. 6. Chilled water coil located on leaving air side (position 2) when used with hot water, steam or electric heat. 7. Chilled water coil located on entering air side (position ) when single coil. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 7
18 AV/AH Coil Section Coil Mount, Hot Water Diagram (Ref ) See Note 6 See Note 5 See Note 5 See Note 6 AIR FLOW See Note 4 See Note 7 See Note 7 See Note 4 LEFT-HAND APPLICATION RIGHT-HAND APPLICATION DETAIL "A" 2 9 Plug from Coil Ref. Note NOTES:. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A". 2. Return label is placed always opposite drain connections. Supply label is placed always at center connection. 3. Braze Item with drain at bottom of connection. 4. Drain connection floor unit or wall unit. 5. Drain connection ceiling. 6. Hot water coil located on leaving air side (position 2) when used with direct expansion coil. 7. Hot water coil located on entering air side (position ) when single coil or with chilled water coil. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 8
19 Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Drain Pan AV GCF504 N/S Drain Pan AV GCF505 N/S Drain Pan AV GCF506 N/S Drain Pan AV GCF507 N/S Drain Pan, -Coil AH GCF5225 N/S Drain Pan, -Coil AH GCF5226 N/S Drain Pan, -Coil AH GCF5227 N/S Drain Pan, -Coil AH GCF5228 N/S Drain Pan, 2-Coil AH GCF509 N/S Drain Pan, 2-Coil AH GCF5020 N/S Drain Pan, 2-Coil AH GCF502 N/S Drain Pan Kit, 2-Coil AH N/S Auxillary Drain Pan (C29 = FTB only) N/S Auxillary Drain Pan (C29 = SFB only) N/S Drain Plug 4RHD896 N/S Shaft, Damper GC0747 N/S Counterweight GC N/S Counterweight GC N/S Crankarm GCF N/S = Not shown on diagram. Damper Section Drain Pan, and Face & Bypass Damper Components UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 9
20 Damper Section OA & Room Air Damper Components Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Damper, OA 500/750 CFM N/S Damper, OA 000 CFM N/S Damper, OA 250 CFM N/S Damper, OA 500 CFM N/S Damper, Room Air 500/750 CFM N/S Damper, Room Air 000 CFM N/S Damper, Room Air 250 CFM N/S Damper, Room Air 500 CFM N/S Bearing, Sleeve 4ACN N/S Spring, Damper N/S Crankarm GCF5474 N/S Crank GCF5000 N/S OA Shaft Assy N/S Shaft until 2/99 GC634 N/S Shaft 2/99 & later N/S Shaft until 2/99 GC0024 N/S Shaft 2/99 to 3/ N/S Right Side Actuator Assy 2/99 & later N/S Gasket BJ Ft. 6 Ft. 7 Ft. 8 Ft. 8 Ft. N/S Mohair BY Ft. 7 Ft. 2 Ft. 25 Ft. 25 Ft. N/S = Not shown on diagram. Replaces counterweight - RA (GC2A), angle, and screw. 2 In February 999, a second "slave" actuator was added to the right side of the room air damper. The new shafts are only used when this additional actuator is present. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 20
21 Hydronic Valves and Actuators Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S 3-Way Valve /2" Connections, #2 Port, 2.2 CV /2" Connections, #4 Port, 4.4 CV /4" Connections, #6 Port, 7.5 CV N/S 2-Way Valve /2" Connections, #2 Port,.3 CV /2" Connections, #3 Port, 2.2 CV /2" Connections, #4 Port, 4.4 CV /4" Connections, #5 Port, 5.5 CV /4" Connections, #6 Port, 7.5 CV " Connections, #7 Port, 0.0 CV " Connections, #8 Port, 4.0 CV N/S End Of Cycle Valve Kits- 2 Way Valves 3/4" Connections, Straight, 8.0 CV /4" Conn., Normally Closed, 7.0 CV " Conn., Normally Open, 7.0 CV N/S End Of Cycle Valve Kits- 3 Way Valves 3/4" Conn, NO/NC, 7.0 CV N/S Actuator Actuator, OA Actuator, FBP Actuator, Water & Steam N/S = Not shown on diagram. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 2
22 Controls Ref. Sch. Description Part Unit Size No. Sym. Number N/S --- PC Board Control MicroTech M N/S Sensor- Humidity Transducer N/S S Sensor- Room Temp Unit Mtd. GEF947 N/S S Sensor- Room Temp Wall Mtd. N/S S2 Sensor, Discharge Air Temp GEF947 N/S S3 Sensor, Outdoor Air 80" GEF948 N/S S4 Sensor, Mixed Air Temp 3 Fan Sensor, Mixed Air Temp 4 Fan Sensor, Mixed Air Temp 5 Fan Sensor, Mixed Air Temp 6 Fan N/S S5 Sensor, Water Temp GEF948 N/S T4 Thermostat, Low Temp DE Coil 4ELN7604 N/S T6 TStat, Low Temp 44" Cap Tube 4ELN978 N/S X Transformer- Motor Speed /4 HP Motor 20V Primary /4 HP Motor 208/265V Primary /3 or /2 HP Motor 5/460/575V 4EPB8039 /3 or /2 HP Motor 208/230/ V 4EPB8040 N/S X2 Transformer- DE Cool 40 VA 5/460/575V VA 208/230V/24V VA 277/24V N/S X3 Transformer- Control 75 VA 20V-24V Sec VA 208/240-24V VA /460-24V 4EPC977 N/S X4 Transformer- Step Down 500 VA 460/240V 4EPC6552A 750 VA 460V 4EPC7743 N/S X5 Transformer 40VA 208/240-24V VA V VA 20-24V N/S X6 Transformer, UVC 4EPC988 N/S --- PC Board Controls Controls By Others T4 Thermostat, Control- DE DE F 4ELN7604 REC Receptacle, 5Amp, Dual Voltage until 4/04 4EGA4209 RC3 Receptacle, DE- 20Amp until 4/04 4EGA4307 Plug, Shorting until 4/04 4EFA9248 Plug 4EFA873 TDR2 Time Delay Relay Anti-Short, 5 min. 4EWS7798 Cord-Set 0Amp, 5V, 07" N/S = Not shown on diagram. Contact local Parts Distributor. Unit model and serial number is required for proper identification. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 22
23 Controls Fuses, Relays, Switches and Time Clock Bub. No. Ref. No. Description Part Number N/S X7 Fuseholder 4EHB933 N/S FC/FD Fuse, X4 Transformer, 4.0 amp 4EHG7663 N/S FC/FD Fuse, X4 Transformer, 3.5 amp 4EHG773 N/S FA Fuse, 0.0 amp 4EHG7795 N/S FA Fuse, 9.0 amp 4EHG8684 N/S FA Fuse, 7.0 amp 4EHG7750 N/S FA Fuse, 6.25 amp 4EHG890 N/S FA Fuse, 5.6 amp 4EHG7749 N/S FA Fuse, 5.0 amp 4EHG8089 N/S FA Fuse, 4.5 amp 4EHG7664 N/S FA Fuse, 4.0 amp 4EHG7663 N/S FA Fuse, 3.5 amp 4EHG773 N/S FA Fuse, 3.0 amp 4EHG7748 N/S --- Cord Set, Motor Plug, 24" 4EFZ7630 N/S --- Cord Set, Motor Receptacle, 6" 4EGZ7629 N/S --- Receptacle, Dual Volt 4EGA4209 N/S --- Receptacle, DE Cool 4EGA4307 N/S R4 Fan Relay until 6/99 4EWJ8505 Fan Relay * 6/99 & later 4EWJ9054 N/S R5 Night Setback Relay 24V 4EWJ9054 Night Setback Relay 5V 4EWJ9053 N/S R6 Vent Lockout Relay 24V 4EWJ9054 Vent Lockout Relay 5V 4EWJ9053 N/S R8 RVSG Valve Relay, DE Cooling 4EWJ8799 N/S C/C Elec. Ht. Relay Operating & Backup 4EWJ8799 N/S R3 Interlock Exhaust Fan Relay 24V 4EWJ9054 Interlock Exhaust Fan Relay 5V 4EWJ9053 N/S TDR Time Delay Relay, Low Volt. Prot. Electric Heat 4EWS7798 N/S SW Switch, Disconnect, Electric Heat, 00 amp 4EUL6509A Switch, Disconnect, Electric Heat, 225 amp 4EVQ639 N/S SW Switch, Disconnect, Non-Electric Heat N/S SW2 Switch, Fan Speed, Remote GE420A N/S SW2 Rotary Switch, 2-Pole (20V, 227V) N/S SW2 Rotary Switch, 3-Pole (208V, 230V) N/S --- Knob (Rotary Switch) N/S SW3 Switch, Day-Night/TOR 4EAL726 N/S SW4 Switch, Holiday 4EAL7260 N/S SW5 Switch, Emergency, Elec. Heat, Heat Pump 4EAL726 N/S SW6 Switch, Energy Conserving, Heat Pump 4EAL7759 N/S TC 24 hour Time Clock with Reserve Power, 20V 4ETA9083 N/S TC 24 hour Time Clock with Reserve Power, V 4ETA9094 N/S Ref. Time Clock Instruction with Reserve Power GE424 N/S = Not shown on diagram. * If 4EWJ9054 is installed on units built prior to June 5, 999, the R4 harness terminals must be field retrofitted with /4" terminals. Dual voltage receptacle was removed from std control box, per PC 9754, effective (Used in "Controls By Others" application.) UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 23
24 Field Installed Accessories Filters Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/05 008/20 N/S Filter, Air- Permanent Aluminum GO006 Box of 25 GO N/S Filter, Air- Permanent Aluminum GO007 Box of 25 GO N/S Filter, Air- Permanent Aluminum GO008 Box of 25 GO N/S Filter, Air- Permanent Aluminum GO Box of 25 GO N/S Filter, Air- Throwaway GO279C Box of 2 GO279C N/S Filter, Air- Throwaway GO280C Box of 2 GO280C N/S Filter, Air- Throwaway GO28C Box of 2 GO28C N/S Filter, Air- Throwaway GO279C 2 2 Box of 2 GO279C N/S Renewable Filter Rack & Media GOF50 Box of 25 GOF N/S Renewable Filter Rack & Media GOF502 Box of 25 GOF N/S Renewable Filter Rack & Media GOF503 Box of 25 GOF N/S Renewable Filter Rack & Media GOF Box of 25 GOF N/S Renewable Media KJ N/S = Not shown on diagram. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL / Page 24
25 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! AAF Unit Ventilators Herman Nelson Unit Ventilators AH , Vintage C UAHB, UAHF, UAHR, UAHV Design 3 Critical Components Unit Sizes Voltage Part Number Control MicroTech M325 Controller ALL ALL Blower Fan Motor Motor, Ball Bearing, /4HP (07-20) 5/60/ Motor, Ball Bearing, /3 HP (07-20) 5/60/ Motor, Ball Bearing, /2 HP (07-20) 5/60/ LADQ5949 Blower Fan Assembly Fan Housing (07-5) N/A Fan Housing 008 (20) N/A GCF532 Fan Wheel, Metal (07-5) N/A Fan Wheel, Plastic (07-5) N/A Fan Wheel, Plastic 008 (20) N/A GF0 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS 5758 Rev. R 0/206 CPL Page of 2
26 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! AAF Unit Ventilators Herman Nelson Unit Ventilators AV , Vintage C UAVB, UAVR, UAVS, UAVV 07-5 Design 3 Critical Components Unit Sizes Voltage Part Number Control MicroTech M325 Controller ALL ALL Blower Fan Motor Motor, Sleeve Bearing, /4HP (07-5) 5/60/ Blower Fan Assembly Fan Housing ALL N/A Fan Wheel ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS 5758 Rev. R 0/206 CPL Page 2 of 2
McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000
Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787
More informationMcQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018
Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or
More informationDaikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017
Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationAAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016
Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)
Replacement Parts List No. 700022700 Revision H 02/208 McQuay Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV 024-054 Designs D (4), E (5) To find your Daikin
More informationAAF Herman Nelson. Self- Contained Unit Ventilator AE, AR, AZ 2-7. Last Manufactured: Replacement Parts List No Revision F 09/2017
Replacement Parts List No. 57300 Revision F 09/07 AAF Herman Nelson Self- Contained Unit Ventilator AE, AR, AZ - 7 Last Manufactured: 99 To find your Daikin Applied parts distributor, call -800-377-787
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationDaikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationMcQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)
Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017
Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)
Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017
Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018
Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018
Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993
Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,
More informationMcQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts
More informationMcQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationMcQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)
Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find
More informationMcQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994
Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787
More informationDaikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017
Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationMcQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988
Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin
More informationMcQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008
Replacement Parts List No. 055237900 Revision R 12/2017 McQuay Seasonmaker ThinLine Horizontal Fan Coil TSH, TSC 031-121 Vintage F FTSH, FTSC 03-12 Designs A(1), B(2) Last Manufactured: 2008 To find your
More informationAAF. Fan Coil XR 1-9. Last Manufactured: Replacement Parts List No Revision B 07/2001
Replacement Parts List No. 057113200 Revision B 07/2001 AAF Fan Coil XR 1-9 Last Manufactured: 1991 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com Table
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998
Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E
Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,
More informationAir Cooled Scroll Compressor Condensing Unit
Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018
Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMicroTech Unit Ventilator
Open Protocol Data Information Packet Version 2.2 Group: Controls Date: April 1996 MicroTech Unit Ventilator Open Protocol Data Communications 2002 McQuay International - C O N F I D E N T I A L - This
More informationMcQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016
Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationMcQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018
Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationClimate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982
Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call
More informationDaikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017
Replacement Parts List No. 7000800 Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage B To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationMcQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007
Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied
More informationMcQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1
Replacement Parts List No. 700008800 Revision M 02/2014 McQuay Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF 007-017 PDHP, PDHA, PDHE, PDHF 007-015 Design 1 To find your Daikin
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationMcQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978
Replacement Parts List No. 055224800 Revision C 10/2017 McQuay Aircon Air Cooled Condenser AMB, APB 020-140 AMD, APD 008-030 Vintage A Last Manufacture: 1978 To find your Daikin Applied parts distributor,
More informationDaikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3
Replacement Parts List No. 70002700 Revision G 02/204 Daikin McQuay Applied PTAC Air Conditioner and Heat Pump PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF 007-07 Design 3 To find your Daikin Applied parts
More informationCatalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet
ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-8 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationOperation & Maintenance Manual
Operation & Maintenance Manual VUD, VUF, VDF & HCD Series Unit Ventilator IMPORTANT: Read and save this manual for future reference. This manual is to be left with the equipment owner 2006 TEMSPEC INCORPORATED
More informationAAF HermanNelson. UniVent Unit Ventilator ZY, AZY, BZY, CZY. Last Manufactured: Replacement Parts List No Revision E 09/2005
Replacement Parts List No. 057112200 Revision E 09/2005 AAF HermanNelson UniVent Unit Ventilator ZY, AZY, BZY, CZY Last Manufactured: 1985 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationVertical V*B Series Fan Coil Technical Catalog
Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with
More informationCatalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet
ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-5 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationcontrol sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals
control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004
More informationFCC Fan-Coil Units High-Performance, Vertical
FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations
More informationCatalog Daikin Classroom Unit Ventilators. Models AHF, AHB, AHV and AHR Ceiling Units. AH Unit
Daikin Classroom Unit Ventilators Models AHF, AHB, AHV and AHR Ceiling Units Catalog 1610-3 AH Unit Contents Introduction.... 3 Daikin Classroom Unit Ventilators.... 3 AHRI Performance... 4 Features &
More informationCHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS
550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.
More informationCATALOG. SKYPAK Self-Contained Heating/Cooling Units
CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationCatalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS
Catalog 722-6 ThinLine Vertical Fan Coils Type FCVC, FCVH, FCVS Vertical Design Model FCVC Model FCVS Table of Contents Table of Contents Nomenclature and Certification... 3 ThinLine Vertical Fan Coils...
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationAIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION
Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available
More informationGas-Fired Indoor and Outdoor Duct Furnaces
July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete
More informationSPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating
SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationSubmittal. RBVR Vertical Concealed Floor Mount FCU RBVR
FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationField Start-Up Sheet Direct Fired Gas Equipment
Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationCatalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS
Catalog 722-8 ThinLine Vertical Fan Coils Type FCVC, FCVH, FCVS Vertical Design Model FCVC Model FCVS Table of Contents Table of Contents Nomenclature and Certification... 3 ThinLine Vertical Fan Coils...
More informationValedictorian - Vertical Unit Ventilator Models VFF and VFV April, 2012
Valedictorian - Vertical Unit Ventilator Models VFF and VFV April, 2012 Introduction Modine Manufacturing Company, located in Racine, Wisconsin, is one of the world s leading manufacturers of heat pump
More informationLarge Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models
Large Capacity Fan Coil Units Catalog 735-12 Belt-Drive and Direct-Drive Cabinet and Hideaway Models Table of Contents Agency Listing and Nomenclature... 3 Overview....................................
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationPARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9
PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9 Revised 12/01/17. APK Manufacturing reserves the right to make changes at any time without notice and without incurring any obligation.
More informationApplied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat
Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features
More informationFAS Fresh Air Supply Units
TGFAS-2 FAS Fresh Air Supply Units TECHNICAL GUIDE STEAM AND HOT WATER MAKE-UP AIR HEATERS WITH INTEGRAL FACE AND BYPASS COILS FOR EFFECTIVE TEMPERATURE CONTROL Since 1875, the L.J. Wing Company has been
More information1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA
PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationDSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER
DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard
More informationDaikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)
Replacement Parts List No. 700026200 Revision E 05/2017 Daikin McQuay Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit AWS 400-550 Vintage B Unit Revision 0B (Code 62) To find your Daikin Applied
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationZone Control Panels. ZoZ one Product Catalog Page 3 ED3 SMZ4SW SMZAC SMZ3SW JTZHP
Zone Control Panels ED3 ED Zone Panels The ED3 and ED4 are configurable microprocessor based control panels. They are suitable for use with gas/electric, oil, electric, conventional, and dual fuel heat
More informationDigital Precise Air Control - DPAC
Digital Precise Air Control - DPAC Mode Enable Sensor Options The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during Occupied operation. The following options
More information9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners
PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,
More informationGAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications
ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationSpecifications and Performance
R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000
More information