NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

Size: px
Start display at page:

Download "NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number"

Transcription

1 TDEVCDP02 April 2009 EVCDP Conventional Dual Optical Detector NITTAN EVCDP Conventional Evolution Dual Optical Detector. F02J82205 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 2 x Light Emitting Diode 12V d.c. to 32V d.c. 40µA at 24v 50mA at 24v 5mA 20 C to + 60 C 1 minute in Clean Air RH95% noncondensing. IP42 /PC alloy 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and STB4) 118g (Sensor head) 183g (Sensor head and STB4 base) EN547: 2000 EN547: 2000 From Control Panel 104 Negative Positive Base : STB4 STB4SD 5 RIL Refer the connection manual 48 + To Next Device

2 TDEVCP06 April 2009 EVCP Conventional Optical Sensor EVCP Conventional Evolution Optical Sensor. F03C82200 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 12V d.c. to 32V d.c. 50µA 50mA 2mA 20 C to + 60 C 20 Seconds RH95% noncondensing. IP40 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN547 : 2000 EN547: 2000 From Control Panel 104 Negative Positive Base : STB4 STB4SE UB4 UB4SD 5 RIL Vdd 48 + To Next Device

3 TDEVCPYIS03 EVCPYIS Conventional Intrinsically Safe Optical Detector December 2009 EVCPYIS Evolution Conventional Intrinsically Safe Optical Detector F02N83300 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 10V d.c. to 32V d.c. 50µA at 24v 50mA at 24v limited by barrier to 0.66W in I.S. zone 2mA 20 C to + 50 C (Limited by ATEX Certification) 1 Minute RH95% noncondensing. IP42 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4IS base) 110g (Sensor head) 170g (Sensor head and UB4IS base) BSEN EN CPD20883 Class 1G (Gas), T4 (Temperature) ITS09ATEX26418X CPD Number ATEX Certification ATEX Cert Number From Control Panel 104 Negative Positive Base : UB4IS RIL Vdd 48 + To Next Device

4 TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN EN545 Base : STB4 STB4SE UB4 UB4SD

5 TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN EN545 Base : STB4 STB4SE UB4 UB4SD

6

7 UB4 Mounting Base Nittan Standard UB4 Mounting base for Detectors Indoor mounting base F03_83500 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 15.00mm 52g EMC conformance to BSEN Complies with EN545,7 Addressable Termination 1 = +VE 3 = RIL VE 2mA 5 = Screen 6 = VE Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 2mA 6 = VE out TDUB4 01 May 2012

8 UB4SD Base Nittan Standard UB4SD Mounting base for Detectors Indoor mounting base F03_83510 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 15.00mm 52g EMC conformance to BSEN Complies with EN545,7 Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 20mA 6 = VE out TDUB4SD 01 June 2012

9 UB4SDR470 Mounting Base Nittan Standard UB4SDR470 Mounting base for Detectors Indoor mounting base F03_83512 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 15.00mm 54g EMC conformance to BSEN Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4SDR June 2012

10 UB4R470 Mounting Base Nittan Standard UB4R470 Mounting base for Detectors Indoor mounting base F03_83503 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 15.00mm 54g EMC conformance to BSEN Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4R June 2012

11 TDSTB4SESWEV 01 STB4SESWEV Savwire Base Nittan Standard STB4SESWEV Savwire base for EV Detectors Indoor savwire base F03_84010 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 23.00mm 78g EMC conformance to BSEN Complies with EN545,7 Terminations: 2 = +VE 1 = VE 5 = RIL VE May 2012

12 SENSORTEC TDSTB4SE01 STB4SE Standard Deep Base Nittan Standard STB4SE Standard Deep Base Indoor mounting base F03_82300 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass 12 to 38V d.c. RH95% noncondensing mm x 23.00mm 78g EMC conformance to BSEN Complies with EN545,7 Conventional Termination Analogue Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out 1 +VE 6 VE 3 RIL VE 2mA 5 Earth May 2012

13 SENSORTEC STB4SESD Base Nittan Standard STB4SESD Diode Deep Base Indoor mounting base F03_82302 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing mm x 23.00mm 78g EMC conformance to BSEN Complies with EN545,7 Conventional Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out TDSTB4SESD 01 May 2012

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04 Document No: Date: SEPT 2015 EV-H ANALOGUE ADDRESSABLE LPCB REF: 041h/01&02 and 842c/03&04 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2008 Hipley Street, Old Woking, Surrey, England,

More information

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley

More information

Evolution Product Range

Evolution Product Range Evolution Product Range World Leading Fire Detection Products from the NITTAN group Analogue Products Smoke / Heat / Flame Sensors CN-P Optical Smoke Detector CN-PH Optical Smoke and Heat Detector Optical

More information

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL 1 of 9 NAM-AS3 INTRODUCTION DESCRIPTION The NAM-AS3 forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to perform a loop powered, addressable

More information

SOUNDER CONTROL MODULE SCM-AS4

SOUNDER CONTROL MODULE SCM-AS4 1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide voltage conventional detectors Series 65 incorporates well-proven sensing technologies, including an IC based on that used in XP95 analogue addressable detectors.

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide Voltage Conventional Detectors Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

DUR 40Ex Intrinsically Safe SMOKE DETECTOR DUR 40Ex Intrinsically Safe SMOKE DETECTOR Installation and Maintenance Manual IK E317 001GB IB Issue 2 IK E317 001GB The Universal Optical Smoke Detector DUR 40Ex covered by the present manual, complies

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection DATASHEET S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS MINERVA S200Plus Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red solar blind flame detection for optimum

More information

Orbis IS Product Guide MAN 3041

Orbis IS Product Guide MAN 3041 Orbis IS Product Guide MAN 3041 TABLE OF CONTENTS Page No. 1 Introduction to Intrinsic Safety... 2 2 Range of Products... 3 3 Features of Orbis IS... 3 4 Choosing a Detector: Q & A... 3 5 Orbis IS Optical

More information

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 Installation Manual dmp-100_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66

More information

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases PRODUCT GUIDE Optical Detector Multisensor Detector Heat Detector Mounting Bases 2...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE Installation and Maintenance Manual IK E303 001GB IIIA Edition 2 IK E303 001GB The SAL 4001 addressable

More information

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A9-Ex Multisensor fire detector FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled

More information

Standard detectors. General information. Product Sheet Detec on

Standard detectors. General information. Product Sheet Detec on General information Loop detectors and modules The detector series offers ionisation smoke detectors, optical smoke detectors, heat detectors and a multisensor detector, communicating with the FMZ 5000

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

optical detector multisensor detector heat detector mounting bases product guide

optical detector multisensor detector heat detector mounting bases product guide optical detector multisensor detector heat detector mounting bases product guide ...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba Cerberus PRO Cerberus FIT Interbases DBS721, DBS728, DBS729 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector

More information

CONTENTS NBM-06 Bell (6") Page 1

CONTENTS NBM-06 Bell (6) Page 1 CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder

More information

Fire & Security Products. Siemens Building Technologies Group

Fire & Security Products. Siemens Building Technologies Group Fire & Security Products Siemens Building Technologies Group . 1 Brief overview.................................................... 1 1.1 Characteristics....................................................

More information

XP95 Intrinsically Safe Product Guide MAN 3054

XP95 Intrinsically Safe Product Guide MAN 3054 XP95 Intrinsically Safe Product Guide MAN 3054 TABLE OF CONTENTS. Page No. 1 Introduction to Intrinsically Safe... 1 2 Classification of Hazardous Areas... 1 3 XP95 I.S. Ionisation Smoke Detector... 3

More information

Salsmästaregatan 21 P.O. Box 8763 SE Gothenburg

Salsmästaregatan 21 P.O. Box 8763 SE Gothenburg Owner of certificate: CN System AB Salsmästaregatan 21 P.O. Box 8763 SE-402 76 Gothenburg Date of issue: 2017-07-31 System Name: Terra Fire Certificate no.: 232.254 Centraludstyr / Alarm panels For optioner

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0149 LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** SIL1 MSH2-LS/HC/CO2 MSH2ia-LS/HC/CO2

More information

PREMIER PLATINUM INFRARED GAS SENSOR

PREMIER PLATINUM INFRARED GAS SENSOR PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Interbases. Sinteso FDSB221, FDSB228, FDSB229 Sinteso Interbases FDSB221, FDSB228, FDSB229 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector bus FDnet Addressed

More information

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0118 PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** SIL1 Non - SIL MSH-PS/HC MSHia-PS/HC

More information

OH110, OP110, HI110 Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation

More information

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multi-sensor fire detector OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multisensor fire detector OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust

More information

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors SERIES 60 CONVENTIONAL FIRE DETECTORS Series 60 is a range of conventional fi re detectors, designed

More information

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone. revision 12 2016 RC Room controller RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone. RC is a room controller in the Regio series. The controller

More information

XP95 ENGINEERING PRODUCT GUIDE

XP95 ENGINEERING PRODUCT GUIDE XP95 ENGINEERING PRODUCT GUIDE Ionisation Smoke Detector Optical Smoke Detector Temperature Detector Multisensor Detector Manual Call Point Isolating Base The XP95 range of intelligent fire detectors is

More information

OH720, OP720, HI720, HI722

OH720, OP720, HI720, HI722 Cerberus PRO OH720, OP720, HI720, HI722 Automatic fire detectors For the automatically addressable detector bus C-NET The ideal fire detector for every application Signal processing with detection algorithms

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Installation and Operating Instruction

Installation and Operating Instruction Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex (i) 9893 0.00 GB Technical changes reserved! 0 Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex

More information

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF DETECTOR TYPE ED816 ZE 1 ZE 2 ZE 3 ZE 4 ZE 5 ZE 6 ZE 7 S ZE 8 CIRCUIT 1 ZE 9 ZE 10 ZE 11 ZE 12 ZE 13 ZE 14 ZE 15 ZE 16 CIRCUIT 1 POWER POWER SUPPLY GENERAL MENT DC GENERAL SYSTEM ALARM DELAYED ALARM RESOUND

More information

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled

More information

Technical data sheet TDS0034

Technical data sheet TDS0034 Technical data sheet TDS0034 PREMIER HYDROCARBON INFRARED SENSOR CERTIFIED VERSIONS TYPES MSH-P-HC and MSHia-P-HC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Room controllers with manual forced ventilation function

Room controllers with manual forced ventilation function revision 12 2016 RC-O Room controllers with manual forced ventilation function RC-O is a room controller from the Regio Mini series intended to control heating and cooling in a single zone. RC-O is a room

More information

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products 7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Linear Heat Detection System Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of specially doped Negative Temperature Coefficient (N.T.C.)

More information

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops... GUIDE MANUAL INDEX 1- Introduction...5...5...6 4- The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops...7 4.2- The Control Panel 4 and 8 Loops...9 5- Installation Guide...10 5.1- Pre-Installation

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 5mm Infrared LED, T-1 Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS

More information

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector Fibre optic sensor for glass fibre optics VL18LL-M/40a/118/128 with M12, 4-pin metal connector U! Clearly aranged control panel with very light LED display! Flashing power on LED in case of short-circuit!

More information

Input/Output Modules Data Sheet

Input/Output Modules Data Sheet Input/Output Modules Data Sheet The wide range of input and output modules available from NOTIFIER delivers exceptional flexibility to a NOTIFIER fire detection and alarm system. Using these modules enables

More information

Instruction Manual EVA-STB-RL

Instruction Manual EVA-STB-RL Instruction Manual EVA-STB-RL Relay Base NITTAN COMPANY, LIMITED -54-5 SASAZUKA, SHIBUYA-KU, TOKYO 5-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully and keep

More information

HOA0880-T51. Representative photograph, actual product appearance may vary.

HOA0880-T51. Representative photograph, actual product appearance may vary. Representative photograph, actual product appearance may vary. HOA0880-T51 HOA Series Infrared Transmissive Sensor, Transistor Output, Two- Mounting Tabs, Plastic package Due to regional agency approval

More information

Interface Modules for SENTRI

Interface Modules for SENTRI EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface

More information

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products 7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products 7 711 Flame Detector QRA4.U Flame detector for use with burner controls from for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate the flame

More information

XP95 Product Guide MAN 3037

XP95 Product Guide MAN 3037 XP95 Product Guide MAN 3037 TABLE OF CONTENTS Page No. 1 Introduction... 1 2 Application of XP95 Detectors... 1 3 Addressing and Communications... 1 4 Approvals & Regulatory Compliance... 2 5 Protocol

More information

Technical data sheet TDS0060

Technical data sheet TDS0060 Technical data sheet TDS0060 PREMIER HIGH RANGE HYDROCARBON INFRARED SENSOR CERTIFIED VERSION TYPES MSH-P-HHC and MSHia-P-HHC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603

More information

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10

More information

RFM Series RFM-ISR Barrier. Installation Manual

RFM Series RFM-ISR Barrier. Installation Manual PSM INSTRUMENTATION LTD RFM Series RFM-ISR Barrier Installation Manual Issue A Burrell Road Industrial Estate Haywards Heath, West Sussex RH16 1TW, UK Tel: +44 (0)1444 410040 Fax: +44 (0)1444 410121 Http://www.psm-sensors.co.uk

More information

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control: 7 711 Flame detector QRA4.U UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control: 7 711 Flame detector QRA4.U UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate

More information

Pyroelectric Infrared Radial Sensor

Pyroelectric Infrared Radial Sensor Pyroelectric Infrared Radial Sensor TYPE: S16-L201D NANYANG SENBA OPTICAL AND ELECTRONIC CO.,LTD. Page 1 of 9 Mini SMD Digital Pyroelectric Infrared Sensor The product is a digital intelligent PIR sensor.

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

LAE10 LFE10. Use. Series 02

LAE10 LFE10. Use. Series 02 ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL

More information

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter ~ Specialists in process suspended solids & turbidity ~ MXD75 Multi Channel Suspended Solids and Turbidity Transmitter Up to 3 Sensors on one Transmitter. Parameters include Suspended Solids, Turbidity

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

Surveyor Envoy-MINI 4

Surveyor Envoy-MINI 4 Surveyor Envoy-MINI 4 CONTENTS SECTION 1 INTRODUCTION Page 4 About this manual Page 4 System design and planning Page 4 Panel types Page 4 General Page 4 SECTION 2 INSTALLATION Page 5 General Page 5 ESD

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

Quadruple-beam photoelectric detector

Quadruple-beam photoelectric detector New generation 4-channel selectable frequencies abh-50/100/150/200/250m Quadruple-beam photoelectric detector Highly Reliable Photoelectric Detector ABH series quadruple-beam photoelectric detector with

More information

Topscan G3 Presence detector for automatic doors

Topscan G3 Presence detector for automatic doors Topscan G3 Presence detector for automatic doors Your added value! Smallest presence detector of its class User-friendly, solid and simple operation Easy and significantly faster installation Mechanically

More information

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Flame detector. Building Technologies Division Infrastructure & Cities Sector 7 711 Flame detector QRA4 UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4... and this Data Sheet are intended for use by OEMs which integrate

More information

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01 909e eries 2/4 Zone Panel Operating and Configuration Manual Version V01 CONTROL & INDICATION FIRE indication per zone. The zone led will flash on non-silenced zones and be continuously lit on silenced

More information

FDCL221 Line separator

FDCL221 Line separator FDCL221 Line separator Technical manual Fire Safety & Security Products Technical specifications and availability subject to change without notice. 2004-2009 Copyright Siemens, Inc. We reserve all rights

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information