CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use

Size: px
Start display at page:

Download "CHAPTER 14 REFERENCED STANDARDS TABLE 14-1 REFERENCED STANDARDS. Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use"

Transcription

1 CHAPTER 14 STANDARDS General Standards. The standards listed in Table 14-1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment regulated by this code. AASHTO M Corrugated Steel Pipe and, Zinc Coated or Piping, Ferrous Aluminum Coated AASHTO M Corrugated Aluminum Alloy and Piping AASHTO M Corrugated Steel Pipe and, Zinc Coated Piping, Ferrous AASHTO M Corrugated CPE Tubing and Piping, Plastic AASHTO M Corrugated Steel Pipe and, Aluminum Coated Piping, Ferrous AASHTO M Corrugated CPE (Heavy Duty) Piping, Plastic AHAM DW * Household Electric Dishwashers Appliances , AHAM FWD * Food Waste Disposers Appliances , ASME A * Scheme for the Identification of Piping Piping , ASME A * Air Gaps in Plumbing (For Plumbing Fixtures and Table 6-2 Water-Connected Receptors) ASME A Air Gap for Use with Plumbing Fixtures, Appliances, Table 6-2 and Appurtenances ASME A * Stainless Steel Drainage for Sanitary DWV, Storm, Piping, Ferrous Table 7-1 and Vacuum Applications, Above- and Below Ground ASME A Macerating Toilet and Related Components Fixtures , (R2010)* (R2004)* ASME A * Water Heater Relief Valve Drain Tubes Appliances , ASME A * Water Closet Personal Hygiene Devices Fixtures , ASME A Plastic for Connecting Water Closets to the Sanitary , Drainage System ASME A * Point of Use and Branch Water Submetering Miscellaneous , ASME A Manually Operated, Quarter-Turn Shutoff Valves for Use in Valves , (R2010) Plumbing (R2010)* ASME A M-1997 (R2008) ASME A (R2010)* ASME A (R2007)* ASME A Floor-Affixed Supports for Off-the-Floor Plumbing Fixtures for Public Use Fixtures , Framing-Affixed Supports for Off-the-Floor Water Closets Fixtures , with Concealed Tanks Floor and Trench Drains DWV Components , Roof, Deck, and Balcony Drains DWV Components , ASME A * Sanitary Floor Sinks Fixtures , ASME A Siphonic Roof Drains DWV Components , (R2010)* ASME A ASME A (R2004)* TABLE 14-1 STANDARDS Backwater Valves Valves , Grease Interceptors Fixtures ,

2 STANDARDS ASME A (R2007)* Grease Removal Devices Fixtures , ASME A * FOG (Fats, Oils, and Greases) Disposal Fixtures ASME A Plumbing Supply 402.6, /CSA B ASME A Plumbing Waste , /CSA B ASME A Flexible Water Connectors Piping , /CSA B * ASME A Deck Mounted Bath/Shower Transfer Valves with Integral Valves , Backflow Protection ASME A Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures Fixtures , /CSA B * (R2004)* ASME A /CSA B * ASME A M-1994 (R2004)* Ceramic Plumbing Fixtures Fixtures 402.1, 402.2, 410.0, Porcelain-Enameled Formed Steel Plumbing Fixtures (Supplement ) Fixtures 401.1, 411.4, 411.5, 411.6, ASME A * Trim for Water-Closet Bowls, Tanks, and Urinals Fixtures , ASME A * Hydromassage Bathtub Appliances Fixtures 401.1, ASME A * Suction for Use in Swimming Pools, Wading Pools, Swimming Pools and Spas and Hot Tubs Spas ASME A M-1991 Non-Vitreous Ceramic Plumbing Fixtures Fixtures (R2002)* ASME A Dual Flush Devices for Water Closets Fixtures , ASME A (R2011)* ASME A (R2007)* ASME A (R2011)* ASME A (R2010)* ASME A (R2011)* ASME A M-1985 (R2007)* ASME A M-1991 ASME B (R2006)* ASME B Wall Mounted, Pedestal Mounted, Adjustable, Elevating, Tilting, and Pivoting Lavatory, Sink, and Shampoo Bowl Carrier and Drainage Waste Fixtures , Electrohydraulic Water Closets Fixtures 401.1, Six-Liter Water Closets Equipped with a Dual Flushing Fixtures 401.1, Device Bathtubs/Whirlpool Bathtubs with Pressure Sealed Doors Fixtures , Vitreous China Nonwater Urinals Fixtures 401.1, Hydrants for Utility and Maintenance Use Valves , Cleanouts DWV Components , Pipe Threads, General Purpose, Inch Joints (2) Dryseal Pipe Threads, Inch Joints , ASME B * Gray Iron Pipe Flanges and Flanged : Classes 25, 604.1, 604.5, , and 250 ASME B * Malleable Iron Threaded : Classes 150 and 300 Table 6-4, Table 7-1 ASME B * Gray Iron Threaded (Classes 125 and 250) Table 6-4 ASME B * Pipe Flanges and Flanged : NPS 1/2 through NPS , Metric/Inch ASME B * Cast Iron Threaded Drainage Table

3 STANDARDS ASME B * Cast Copper Alloy Threaded : Classes 125 and 250 Table 6-4 ASME B Cast Copper Alloy Solder Joint Pressure Table 6-4 (R2005)* ASME B (R2010)* ASME B (R2006)* Wrought Copper and Copper Alloy Solder Joint Pressure , Table 6-4 Cast Copper Alloy Solder Joint Drainage : DWV Table 7-1 ASME B * Cast Copper Alloy Pipe Flanges and Flanged : , Classes 150, 300, 600, 900, 1500 and 2500 ASME B * Cast Copper Alloy for Flared Copper Tubes Table 6-4 ASME B * Wrought Copper and Wrought Copper Alloy Solder-Joint Table 7-1 Drainage DWV ASME B * Valves-Flanged, Threaded, and Welding End Valves , ASME B * Malleable Iron Threaded Pipe Unions: Classes 150, 250 and , (Includes Revision Services) ASME B * Large Diameter Steel Flanges: NPS 26 through NPS , Metric/Inch ASME B Wrought Copper and Copper Alloy Braze-Joint Pressure ASSE * Atmospheric Type Vacuum Breakers Backflow Protection Table 6-2 ASSE * Anti-Siphon Fill Valves for Water Closet Tanks Backflow Protection Table 6-2 ASSE * Water Pressure Reducing Valves for Domestic Water Distribution Valves , ASSE * Backflow Prevention Requirements for Commercial Dishwashing Backflow Protection , Machines ASSE * Residential Use Dishwashers Appliances , , ASSE * Home Laundry Equipment Appliances , ASSE * Plumbing Aspects of Residential Food Waste Disposer Units Appliances , ASSE * Commercial Food Waste Grinder Units Appliances , ASSE * Water Hammer Arresters Miscellaneous, Water , Supply Component ASSE * Hose Connection Vacuum Breakers Backflow Protection , ASSE * Backflow Preventers with an Intermediate Atmospheric Vent Backflow Protection , ASSE * Reduced Pressure Principle Backflow Preventers and Reduced Backflow Protection Table 6-2 Pressure Principle Fire Protection Backflow Preventers ASSE * Backflow Prevention Devices for Hand-Held Shower Backflow Protection , ASSE * Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies Backflow Protection Table 6-2 ASSE * Automatic Compensating Valves for Individual Showers and Valves Tub/Shower Combinations ASSE * Temperature Actuated Mixing Valves for Hot Water Distribution Valves , ASSE * Trap Seal Primer Valves-Potable Water Supplied Valves , ASSE * Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Backflow Protection Table 6-2 Draining Type ASSE * Pressure Vacuum Breaker Assembly Backflow Protection Table 6-2 ASSE Drains Air Gaps for Domestic Dishwasher Applications Backflow Protection , ASSE * Backflow Preventer for Beverage Dispensing Equipment Backflow Protection , Table 6-2 ASSE Hot Water Dispensers Household Storage Type-Electrical Appliances , ASSE * Dual Check Backflow Preventers Backflow Protection ,

4 STANDARDS ASSE * Dual Check Valve Type Backflow Preventers for Carbonated Backflow Protection , Beverage Dispensers, Post Mix Type ASSE * Laboratory Faucet Backflow Preventers Backflow Protection , ASSE Pressurized Flushing Devices (Flushometers) for Plumbing Backflow Protection , Fixtures ASSE * Trap Seal Primer Devices-Drainage Types and Electronic DWV Components , Design Types ASSE * Reduced Pressure Detector Fire Protection Backflow Prevention Backflow Protection Table 6-2 Assemblies ASSE * Double Check Detector Fire Protection Backflow Prevention Backflow Protection Table 6-2 Assemblies ASSE * Stack Air Admittance Valves for Sanitary Drainage ASSE Individual and Branch Type Air Admittance Valves for Sanitary Drainage ASSE * Hose Connection Backflow Preventers Backflow Protection , ASSE * Chemical Dispensing Backflow Protection , ASSE * Spill Resistant Vacuum Breakers Backflow Protection Table 6-2 ASSE Freeze Resistant Sanitary Yard Hydrant with Backflow Backflow Protection , Protection ASSE * Outdoor Enclosures for Fluid Conveying Components Miscellaneous , ASSE * Push-Fit Table 6-4 ASSE * Temperature Actuated Flow Reduction (TAFR) Valves for Individual Fixture Valves , ASSE Individual Pressure Balancing In-Line Valves for Individual Valves , Fixture ASSE * Automatic Temperature Control Mixing Valves Valves ASSE * Water Temperature Limiting Devices Valves 412.1, 414.5, ASSE Dielectric Pipe Unions Joints ASTM A Ferritic Malleable Iron Castings Piping, Ferrous , (R2009) ASTM A Gray Iron Castings Piping, Ferrous , (R2008) ASTM A 53/A 53M-2010 Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded, Piping, Ferrous Table 6-4, Table 7-1 and Seamless ASTM A Cast Iron Soil Pipe and Piping, Ferrous Table 7-1 ASTM A Gray Iron Castings for Valves, Flanges, and Pipe Piping, Ferrous , (R2009) ASTM A Cupola Malleable Iron Piping, Ferrous , (R2006) ASTM A Seamless and Welded Austenitic Stainless Steel Tubing for Piping, Ferrous Table 6-4 General Service ASTM A Seamless, Welded, and Heavily Cold Worked Austenitic Piping, Ferrous Table 6-4 Stainless Steel Pipes ASTM A Ductile-Iron Pressure Pipe Piping, Ferrous , (R2008) e1 ASTM A Corrosion-Resistant High-Silicon Iron Castings Piping, Ferrous , (R2008) ASTM A (R2009) Ductile Iron Castings Piping, Ferrous , ASTM A 653/A 653M Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process Piping, Ferrous ,

5 STANDARDS ASTM A Welded and Seamless Carbon Steel and Austenitic Stainless (R2009) e1 Steel Pipe Nipples Piping, Ferrous , ASTM A Corrugared Steel Pipe Piping, Ferrous ASTM A High-Silicon Iron Pipe and Piping, Ferrous , (R2008) ASTM A Hubless Cast Iron Soil Pipe and for Sanitary and Storm Drain, Waste, and Vent Piping Applications Piping, Ferrous Table 7-1 ASTM B (R2009) Refined Lead Joints , ASTM B Solder Metal Joints , ASTM B Seamless Copper Pipe, Standard Sizes Piping, Copper Alloy Table 6-4 ASTM B Seamless Red Brass Pipe, Standard Sizes Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B (R2010) Seamless Copper Tube Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B Seamless Copper Water Tube Piping, Copper Alloy 604.3, , (1), (1), Table 6-4 ASTM B Seamless Brass Tube Piping, Copper Alloy Table 6-4 ASTM B Copper Sheet, Strip, Plate, and Rolled Bar Miscellaneous , ASTM B Copper, Bus Bar, Rod, and Shapes and General Purpose Rod, Miscellaneous , Bar, and Shapes ASTM B Corrugated Aluminum Pipe Piping ASTM B General Requirements for Wrought Seamless Copper and Piping, Copper Alloy Table 6-4, Table 7-1 Copper-Alloy Tube ASTM B Seamless Copper Tube for Air Conditioning and Refrigeration Piping, Copper Alloy (1), (2) Field Service ASTM B Threadless Copper Pipe, Standard Sizes Piping, Copper Alloy Table 6-4, Table 7-1 ASTM B Copper Drainage Tube (DWV) Piping, Copper Alloy , Table 7-1 ASTM B Copper Sheet and Strip for Building Construction Miscellaneous , ASTM B Welded Copper Tube Piping, Copper Alloy Table 6-4 ASTM B a Copper Alloy Sand Castings for General Applications Piping, Copper Alloy , ASTM B Welded Brass Tube Piping, Copper Alloy , ASTM B Brass, Copper, and Chromium-Plated Pipe Nipples Piping, Copper Alloy , (R2005) e1 ASTM B Liquid and Paste Fluxes for Soldering of Copper and Copper Joints Alloy Tube ASTM B Seamless Copper Tube for Medical Gas Piping, Copper Alloy (1), (3) (R2006) ASTM B Making Capillary Joints by Soldering of Copper and Copper Joints (R2010) Alloy Tube and ASTM C Nonreinforced Concrete Sewer, Storm Drain, and Culvert Piping, Non-Metallic Table 7-1 Pipe ASTM C Asbestos-Cement Pressure Pipe Piping, Non-Metallic Table 6-4 (R2009) e1 ASTM C a Concrete Drain Tile Piping, Non-Metallic , ASTM C Compression Joints for Vitrified Clay Pipe and Joints (R2009) ASTM C Asbestos-Cement Nonpressure Sewer Pipe Piping, Non-Metallic Table 7-1 (R2006) ASTM C Joints for Concrete Pipe and Manholes, Using Rubber Joints , Gaskets ASTM C Precast Reinforced Concrete Manhole Sections Miscellaneous , ASTM C a Rubber Gaskets for Cast Iron Soil Pipe and Joints

6 STANDARDS ASTM C Vitrified Clay Pipe, Extra Strength, Standard Strength, and Piping, Non-Metallic Table 7-1 Perforated ASTM C Borosilicate Glass Pipe and for Drain, Waste, and Piping, Non-Metallic , (R2010) Vent (DWV) Applications ASTM C Flexible Transition Couplings for Underground Piping Joints , ASTM C a Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Joints , ASTM C Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Joints , Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing ASTM C Shielded Transition Couplings for Use With Dissimilar DWV Joints , Pipe and Above Ground ASTM C Mechanical Couplings Using Thermoplastic Elastomeric Joints , (TPE) Gaskets for Joining Drain, Waste, and Vent (DWV), Sewer, Sanitary, and Storm Plumbing for Above and Below Ground Use ASTM C a Heavy Duty Shielded Couplings Joining Hubless Cast Iron Joints , Soil Pipe and ASTM D Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules Piping, Plastic Table and 80 (R2005)* ASTM D Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Piping, Plastic , Poly (Vinyl Chloride) (CPVC) Compounds ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80,, Table 7-1 and 120 ASTM D Rubber Rings for Asbestos-Cement Pipe Joints (R2010) ASTM D Polyethylene (PE) Plastic Pipe, Schedule 40 Piping, Plastic ASTM D Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Joints Plastic Pipe and ASTM D * Polyethylene (PE) Plastic Pipe, (SDR-PR) Based on Controlled Inside Diameter ASTM D * Poly (Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) ASTM D * Underground Installation of Thermoplastic Pipe for Sewers Piping, Plastic , and Other Gravity-Flow Applications ASTM D * Polyethylene (PE) Plastic Pipe, Schedule 40 and 80, Based Piping, Plastic on Outside Diameter ASTM D * Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe, Table 6-4 Schedule 80 ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedule 40 Table 6-4 (R2011)* ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedule 80 Table 6-4 ASTM D Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Joints (R2009) * Piping ASTM D Plastic Insert for Polyethylene (PE) Plastic Pipe Table 6-4 ASTM D * Heat Fusion Joining of Polyolefin Pipe and Joints , ASTM D * Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Piping, Plastic Table 7-1 Drain, Waste, and Vent Pipe and ASTM D * Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Piping, Plastic Table 7-1 Pipe and ASTM D a Joints for IPS PVC Pipe Using Solvent Cement Joints , (R2009)* 116

7 STANDARDS ASTM D (R2009)* Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Composite Sewer Piping Piping, Plastic Table 7-1 ASTM D * Socket-Type Polyethylene for Outside Diameter- Table 6-4, Table 7-1 Controlled Polyethylene Pipe and Tubing ASTM D * Polyethylene (PE) Plastic Tubing ASTM D * Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Piping, Plastic , ASTM D * Underground Installation of Thermoplastic Pressure Piping Piping, Plastic , ASTM D b* Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution ASTM D Making Solvent-Cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and (R2010)* ASTM D (R2007) e1 * Filament-Wound Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe Joints , Piping, Plastic , ASTM D * Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Piping, Plastic , ASTM D * Polyethylene (PE) Plastic Pipe (DR -PR) Based on Controlled Outside Diameter ASTM D Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and Joints , ASTM D Solvent Cements for Transition Joints Between Acrylonitrile- Joints , Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-Pressure Piping Components ASTM D Joints for Plastic Pressure Pipes Using Flexible Elastomeric Joints Seals ASTM D * Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Joints Seals ASTM D a* Butt Heat Fusion Polyethylene (PE) Plastic for Polyethylene Table 6-4, Table 7-1 (PE) Plastic Pipe and Tubing ASTM D a* Drain, Waste, and Vent (DWV) Plastic Patterns , ASTM D Glass-Fiber Reinforced Polyester Manholes Miscellaneous (R2009)* (R2011)* (R2011)* ASTM D * Rigid Acrylonitrile-Butadiene-Styrene (ABS) Materials for Piping, Plastic , Pipe and ASTM D * Chlorinated Polyethylene (CPE) Sheeting for Concealed Miscellaneous , Water-Containment Membrane ASTM D a Polypropylene Injection and Extrusion Materials Miscellaneous , ASTM D Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Miscellaneous , (R2008) e1 * Water-Containment Membrane ASTM D Determining the Performance of Oil/Water Separators Miscellaneous , (R2003) Subjected to Surface Run-Off ASTM E b* Surface Burning Characteristics of Building Materials Miscellaneous 701.1(2), 903.1(2), ASTM E b* Fire Tests of Building Construction and Materials Miscellaneous , ASTM E * Fire Tests of Penetration Firestop Miscellaneous , ASTM F * Safe Handling of Solvent Cements, Primers, and Cleaners Joints , Used for Joining Thermoplastic Pipe and ASTM F * Corrugated Polyethylene (PE) Pipe and Piping, Plastic ASTM F Thermoplastic Accessible and Replaceable Plastic Tube and Piping, Plastic , Tubular ASTM F * Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Table 6-4 Pipe, Schedule

8 STANDARDS ASTM F * Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedule 40 ASTM F * Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedule 80 ASTM F * Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 ASTM F * Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) ASTM F b e1 * Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), Schedule 40 and Schedule 80 ASTM F * Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and ASTM F * Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core Table 6-4 Table 6-4 Piping, Plastic , Joints Piping, Plastic Table 7-1 ASTM F * Primers for Use in Solvent Cement Joints of Poly (Vinyl Joints Chloride) (PVC) Plastic Pipe and ASTM F * Large Diameter Corrugated Polyethylene Pipe and Piping, Plastic , ASTM F * Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter ASTM F Poly (Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Based on Controlled Inside Diameter (R2009)* Piping, Plastic Table 7-1 Piping, Plastic Table 7-1 ASTM F * Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Piping, Plastic , Waste Disposal Absorption Fields ASTM F * Crosslinked Polyethylene (PEX) Tubing ASTM F * Crosslinked Polyethylene (PEX) Plastic Hot- and Cold-Water Distribution ASTM F * Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core ASTM F * Polyethylene (PE) Large Diameter Profile Wall Sewer and Drain Pipe ASTM F * Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a Smooth Interior and ASTM F Electrofusion Type Polyethylene for Outside Diameter Controlled Polyethylene Pipe and Tubing (R2006)* ASTM F * Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube Piping, Plastic Table 7-1 Piping, Plastic , Piping, Plastic , Table 6-4, Table 7-1 Piping, Plastic ASTM F * Crosslinked Polyethylene/Aluminum/ Crosslinked Polyethylene (PEX -AL -PEX) Pressure Pipe ASTM F * Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe ASTM F * Pressure-Rated Composite Pipe and for Elevated Piping, Plastic , Temperature Service ASTM F * Poly (Vinyl Chloride) (PVC) Gasketed Sewer , ASTM F * Polyolefin Pipe and for Corrosive Waste Drainage Piping, Plastic , ASTM F * Performance of Gasketed Mechanical Couplings for Use in Joints , Piping Applications ASTM F e1 * Coextruded Composite Pipe Piping, Plastic Table 7-1 ASTM F Coextruded Composite Drain, Waste, and Vent Pipe (DWV) Piping, Plastic ,

9 STANDARDS ASTM F * Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage ASTM F * Rehabilitation of Existing Pipelines and Conduits by Pulledin-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP) ASTM F e1 * Metal Insert Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing ASTM F * Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated ASTM F * Cold Expansion with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing ASTM F * Metal Mechanical Cold Flare Compression with Disc Spring for Crosslinked Polyethylene (PEX) Tubing ASTM F * Special Engineered, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) ASTM F * Metal Insert for Polyethylene/ Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe ASTM F Multilayer Pipe Type 2, Compression, and Compression Joints for Hot and Cold Drinking-Water (R2006)* Piping, Plastic , Piping, Plastic , Table 6-4 Table 7-1 Table 6-4 Table 6-4 Table , ASTM F * Cold-Expansion with Metal Compression-Sleeves for Table 6-4 Crosslinked Polyethylene (PEX) Pipe ASTM F * Stainless Steel Clamps for Securing SDR9 Cross-linked Joints Table 6-4 Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert ASTM F * Plastic Insert Utilizing a Copper Crimp Ring for Joints Table 6-4 SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing ASTM F Flexible Pre-Insulated Piping Piping, Plastic , ASTM F * Crosslinked Polyethylene/Aluminum/ Crosslinked Polyethylene Tubing OD Controlled SDR9 ASTM F Specification for 12 to 60 in. [300 to 1500 mm] Annular Piping, Plastic , Corrugated Profile-Wall Polyethylene (PE) Pipe and for Gravity-Flow Storm Sewer and Subsurface Drainage Applications ASTM F Pressure-Rated Polypropylene (PP) Piping ASTM F * Metal Insert Utilizing a Copper Crimp Ring for Table 6-4 SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing ASTM F CPE Storm Sewer Piping Piping, Plastic ASTM F HDPE Grease Interceptor Fixtures , ASTM F Specification for 6 to 30 in. Polypropylene (PP) Corrugated Piping, Plastic Single Wall Pipe and Double Wall Pipe. ASTM F Specification for 6 to 30 in. Polypropylene (PP) Triple Wall Piping and, Pipe and for Non-Pressure Sanitary Sewer Applications Plastic AWS A * Filler Metals for Brazing and Braze Welding Joints AWWA C * Ductile-Iron and Gray-Iron Table 6-4 AWWA C * Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Joints

10 STANDARDS AWWA C * Ductile-Iron Pipe, Centrifugally Cast Piping, Ferrous Table 6-4 AWWA C * Ductile-Iron Compact for Water Service Table 6-4 AWWA C * Coal-Tar Protective Coatings and Linings for Steel Water Miscellaneous , Pipelines - Enamel and Tape Hot Applied AWWA C * Fusion-Bonded Epoxy Coating for the Interior and Exterior Miscellaneous , of Steel Water Pipelines AWWA C * Extruded Polyolefin Coatings for the Exterior of Steel Water Miscellaneous , Pipelines AWWA C * Asbestos-Cement Pressure Pipe, 4 in. through 16 in. (100 Piping, Non-Metallic mm through 400 mm) for Water Distribution and Transmission AWWA C * Metal-Seated Gate Valves for Water Supply Service Valves , AWWA C * Rubber Seated Butterfly Valves, 3 in. (75 mm) through 72 in. (1800 mm) Valves , AWWA C * Ball Valves, 6 in. through 48 in. (150 mm through 1200 mm) Valves , AWWA C * Double Check Valve Backflow Prevention Assembly Backflow Protection Table 6-2 AWWA C * Reduced-Pressure Principle Backflow Prevention Assembly Backflow Protection Table 6-2 AWWA C * Grooved and Shouldered Joints Joints , AWWA C * Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated, 4 in. through 12 in. (100 mm through 300 mm), for Water Transmission and Distribution AWWA C * Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. (13 mm) through 3 in. (76 mm), for Water Service AWWA C * Cross-Linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm), for Water Service AWWA C * Injection-Molded Polyvinyl Chloride (PVC) Pressure, 4 in. through 12 in. (100 mm through 300 mm), for Water Distribution CISPI Couplings for Use in Connection with Hubless Cast Iron Soil Pipe and for Sanitary and Storm Drain, Waste, and Vent Piping Applications , Joints , , CSA A Concrete Pipe and Manhole Sections Piping , CSA B (R2008) General Requirements for Plumbing Fixtures Fixtures , CSA B Porcelain-Enameled Steel Plumbing Fixtures Fixtures CSA B (R2008) Plastic Plumbing Fixtures Fixtures , CSA B (R2008) Macerating and Related Components DWV Components , CSA B (R2006) Hydromassage Bathtubs Fixtures , CSA B Glass Lavatories Fixtures , CSA B Backflow Preventers and Vacuum Breakers Backflow Protection , CSA B Atmospheric Vacuum Breakers (AVB) Backflow Protection Table 6-2 CSA B Pressure Vacuum Breakers (PVB) Backflow Protection Table 6-2 CSA B Hose Connection Vacuum Breakers (HCVB) Backflow Protection , CSA B Hose Connection Dual Check Vacuum Breakers (HCDVB) Backflow Protection Table 6-2 CSA B Reduced Pressure Principle (RP) Backflow Preventers Backflow Protection Table 6-2 CSA B Reduced Pressure Principle Backflow Preventers for Fire Backflow Protection Table 6-2 Protection (RPF) CSA B Double Check Valve (DVCA) Backflow Preventers Backflow Protection Table 6-2 CSA B Double Check Valve Backflow Preventers for Fire Protection Backflow Protection Table 6-2 (DVCAF) CSA B Laboratory Faucet Vacuum Breakers (LFVB) Backflow Protection , CSA B Commercial and Residential Drains and Cleanouts DWV Components , CSA B Plumbing 412.1, 414.5, 417.3, Table

11 STANDARDS CSA B /B Design and Installation of Non-Potable Water /Maintenance and Field Testing of Non-Potable Water Miscellaneous , CSA B Polyethylene (PE) Pipe, Tubing, and for Cold-Water Pressure Services CSA B Crosslinked Polyethylene (PEX) Tubing for Pressure Applications CSA B Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe CSA B Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Composite Pressure-Pipe CSA B Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Piping, Plastic , Drainage CSA B Groove- and Shoulder-Type Mechanical Pipe Couplings , CSA B Water Pressure Reducing Valves for Domestic Water Supply Valves , CSA G Corrugated Steel Pipe Products Piping, Ferrous , CSA LC Appliance Stands and Drain Pans Miscellaneous , (R2005)* CSA Z a-2009* Gas Water Heaters Volume I, Storage Water Heaters with Fuel Gas, Appliances , Input Ratings of Btu Per Hour or Less (same as CSA 4.1a) CSA Z b-2008 Gas Water Heaters Volume III, Storage Water Heaters with Fuel Gas, Appliances Input Ratings Above Btu Per Hour, Circulating and Instantaneous (same as CSA 4.3b) CSA Z21.13a-2010* Gas-Fired Low Pressure Steam and Hot Water Boilers (same Fuel Gas, Appliances , as CSA 4.9a) CSA Z21.22b-2001 Relief Valves for Hot Water Supply (same as CSA Valves , b) CSA Z21.56a-2008* Gas-Fired Pool Heaters (same as CSA 4.7a) Fuel Gas, Swimming USPSHTC Pools, Spas, and Hot Tubs FCI Spring Loaded Lift Disc Check Valve Valves IAPMO IGC Specialized Miscellaneous Plastic DWV and Fitting Assemblies IAPMO IGC Movable Sink Fixtures IAPMO IGC Tub/Shower Enclosures and Shower Panel Assemblies Fixtures , IAPMO IGC Ball Valves Valves , IAPMO IGC Non-Flushing Urinals Fixtures IAPMO IGC Glass Lavatories, Sinks and Counter Tops Fixtures , IAPMO IGC Oil/Water Separators and Condensing Plate Separators Fixtures , IAPMO IGC Roof Drains with Integral Overflow Fixtures IAPMO IGC Removable and Non-Removable Push Fit IAPMO IGC Safety Plates, Plate Straps, Notched Plates and Safety Collars Miscellaneous , IAPMO IGC a Copper Alloy or Aluminum Alloy Sinks and Lavatories Fixtures , IAPMO IGC Floor Drain with Integrated Bonding Flange Fixtures IAPMO IGC Metallic Bathtubs, Shower Pans and Whirlpool Bathtubs Fixtures , IAPMO IGC In-Flow Test Tees IAPMO IGC a Drinking Water Fountains With or Without Chiller or Heater Fixtures , IAPMO IGC Coupling for Hubless Cast Iron Pipe Joints IAPMO IGC a Hinge Type Couplings Used For Joining Hubless Cast Iron Joints Oil Pipe and IAPMO PS Sub Drains for Built-Up Shower Pans Fixtures (R2010)* 121

12 STANDARDS IAPMO PS a Dishwasher Drain Airgaps Backflow Protection , IAPMO PS Metallic for Joining Polyethylene Pipe for Water Joints , Service and Yard Piping IAPMO PS Encasement Sleeve for Potable Water Pipe and Tubing Piping , IAPMO PS Lead Free Sealing Compounds for Threaded Joints Joints , IAPMO PS Black Plastic PVC or PE Pressure-Sensitive Corrosion Miscellaneous , Preventive Tape IAPMO PS Pipe Alignment & Secondary Support Miscellaneous , IAPMO PS Cushioned Bathtubs and Whirlpool Bathtub Appliances Fixtures , IAPMO PS Field-Fabricated Tiling Kits Miscellaneous , IAPMO PS Flush Valves with Dual Flush Device For Water Closets or Fixtures , Water Closet Tank with an Integral Flush Valves with a Dual Flush Device IAPMO PS Plastic and Metallic Expansion Joints Joints , IAPMO PS Pump/Dose, Sumps and Sewage Ejector Tanks with or DWV Components , without a Pump IAPMO PS Grooved Mechanical Pipe Couplings and Grooved End Joints , IAPMO PS Metallic and Plastic Utility Boxes Miscellaneous , IAPMO PS Bathwaste Strainer Drains Fixtures , IAPMO PS PVC Hydraulically Actuated Diaphragm Type Water Control Valves , Valves IAPMO PS Sewage Holding Tank Containing Sewage Ejector Pump for DWV Components , Direct Mounted Water Closet IAPMO PS a Fabricated Stainless steel Water Closets or Urinals Fixtures 401.1, 402.1, 402.2, IAPMO PS Plastic Leaching Chambers DWV Components , IAPMO PS a Pipe Flashings Miscellaneous , IAPMO PS Airgap Units for Water Conditioning Equipment Installation Backflow Protection IAPMO PS Dielectric Waterway , IAPMO PS Early-Closure Replacement Flappers or Early-Closure Fixtures , Replacement Flapper with Mechanical Assemblies IAPMO PS Bathwaste and Overflow Assemblies with Tub Filler Spout DWV Components , IAPMO PS Valves with Atmospheric Vacuum Breakers Valves , IAPMO PS Dental Vacuum Pumps Miscellaneous , IAPMO PS Ballcock or Flushometer Valve Tailpiece Trap Primers and Trap Primer Receptors/Adapters DWV Components , IAPMO PS Multiport Electronic Trap Primer DWV Components , IAPMO PS Clarifiers DWV Components , IAPMO PS Precast Concrete Seepage Pit Liners and Covers DWV Components , IAPMO PS Fiberglass (Glass Fiber Reinforced Thermosetting Resin) , IAPMO PS Tools for Mechanically Formed Tee Connections in Copper Miscellaneous , Tubing IAPMO PS Rainwater Diverter Valve for Non-Roofed Area Slabs DWV Components , IAPMO PS Diverter and Shutoff Valves for Pool/Spas Swimming Pools, USPSHTC Spas, and Hot Tubs IAPMO PS Pre-Pressurized Potable Water or Expansion Tanks Miscellaneous , IAPMO PS Soaking and Hydrotherapy (Whirlpool) Bathtubs with Fixtures , Hydraulic Seatlift IAPMO PS Elastomeric Test Caps/Cleanout Caps DWV Components , IAPMO PS a Plastic Stabilizers for Use with Plastic Closet Bends DWV Components , IAPMO PS Heat Exchangers and Indirect Water Heaters Miscellaneous ,

13 STANDARDS IAPMO PS a Water Closets with Spray, Water Closet Seats with Spray and Fixtures Other Devices with Spray for Water Closets Supplied with Hot and Cold Water IAPMO PS P-Trap, Supply Stop and Riser Insulated Protector Miscellaneous , IAPMO PS Drain, Waste, and Vent Hangers and Plastic Pipe Support Hooks DWV Components , IAPMO PS Passive Direct Solar Water Heaters Appliances USEC IAPMO PS Prefabricated Fiberglass Church Baptisteries Fixtures , IAPMO PS Terrazzo, Marble, Concrete, Granite, and Slate Plumbing Fixtures , Fixtures IAPMO PS Porous Filter Protector for Sub-Drain Weep Holes DWV Components , IAPMO PS Suction Relief Valves Valves , IAPMO PS Pressure Relief Connection for Dispensing Equipment Valves , IAPMO PS Polyethylene Distribution Boxes DWV Components , IAPMO PS Pre-Fabricated, Tileable Shower Receptors Fixtures , IAPMO PS a PVC Cold Water Compression , IAPMO PS PVC Cold Water Gripper , IAPMO PS PVC Plastic Valves for Cold Water Distribution Valves , Outside a Building and CPVC Plastic Valves for Hot and Cold Water Distribution IAPMO PS Hydraulically Powered Household Food Waste Disposers Appliances , IAPMO PS e1 Remote Floor Box Industrial Water Supply, Air Supply, Miscellaneous , Drainage IAPMO PS Hot Water On-Demand or Automatic Activated Hot Water Miscellaneous , Pumping IAPMO PS Hot Water Circulating Devices Which Do Not Use a Pump Miscellaneous , IAPMO PS Copper and Copper Alloy Tubing System Incorporating Press-Type or Nail-Type Connections , IAPMO PS Water Energized Sump Pump Miscellaneous , IAPMO Z * Plastic Bathtub and Shower Units Fixtures , IAPMO Z * Plastic Lavatories Fixtures , IAPMO Z * Plastic Water Closet Bowls and Tanks Fixtures , IAPMO Z * Plastic Toilet (Water Closet) Seats Fixtures , IAPMO Z Plastic Sinks Fixtures , IAPMO Z * Prefabricated Plastic Spa Shells Fixtures, Swimming Pools, Spas, and Hot , 301.2, USPSHTC Tubs IAPMO Z * Plastic Bathtub Liners Fixtures , IAPMO Z * Plastic Urinal Fixtures Fixtures ISEA Z * Emergency Eyewash and Shower Equipment Miscellaneous 416.1, ISO/IEC Guide General Requirements for Bodies Operating Product Certification Certification , MSS SP * Marking for Valves,, Flanges, and Unions Miscellaneous , MSS SP * Corrosion Resistant Gate, Globe, Angle and Check Valves Piping, Ferrous , with Flanged and Butt Weld Ends (Classes 150, 300 & 600) MSS SP * Steel Pipeline Flanges , MSS SP Pipe Hangers and Supports Materials, Design, Manufacture, Fuel Gas Selection, Application, and Installation MSS SP a* Butterfly Valves Valves , MSS SP * Pipe Hangers and Supports -Selection and Application Miscellaneous MSS SP * Gray Iron Gate Valves Flanged and Threaded Ends Valves ,

14 STANDARDS MSS SP * Gray Iron Swing Check Valves, Flanged and Threaded Ends Valves , MSS SP * Ball Valves with Flanged or Butt-Welding Ends for General Valves , Service MSS SP a* Gray Iron Plug Valves Flanged and Threaded Ends Valves , MSS SP * Bronze Gate, Globe, Angle, and Check Valves Valves , MSS SP * Class 3000 Steel Pipe Unions Socket Welding and Threaded Joints , MSS SP * Pipe Hangers and Supports-Fabrication and Installation Practices Miscellaneous , MSS SP * Wrought Copper Solder Joint Pressure , MSS SP * Cast Copper Alloy Flanges and Flanged : Class 125, , and 300 MSS SP Welded Fabricated Copper Solder Joint Pressure , (R2006)* MSS SP (R2006)* Non-Ferrous Threaded and Solder Joint Unions for Use with Copper Water Tube Joints , NFPA 99c-2012* Gas and Vacuum Piping , NSF * Food Equipment Appliances , NSF * Commercial Warewashing Equipment Appliances , NSF * Commercial Cooking, Rethermalization, and Powered Hot Appliances , Food Holding and Transport Equipment NSF * Water Heaters, Hot Water Supply Boilers, and Heat Recovery Appliances , Equipment NSF * Automatic Ice Making Equipment Appliances , NSF * Plastics Piping System Components and Related Materials Piping, Plastic 301.1, NSF * Manual Food and Beverage Dispensing Equipment Appliances , NSF * Detergent and Chemical Feeders for Commercial Spray-Type Appliances , Dishwashing Machines NSF * Residential Wastewater Treatment DWV Components , NSF * Non-Liquid Saturated Treatment DWV Components , NSF * Drinking Water Treatment Units Aesthetic Effects Appliances NSF * Residential Cation Exchange Water Softeners Appliances NSF * Evaluation of Components and Devices Used in Wastewater DWV Components , Treatment NSF e* Drinking Water Treatment Units Health Effects Appliances 611.3, L NSF * Ultraviolet Microbiological Water Treatment Appliances NSF * Reverse Osmosis Drinking Water Treatment Appliances 611.2, NSF a* Drinking Water System Components Health Effects Water Supply Components 604.1, 605.1, NSF 61 G Drinking Water System Components Health Effects Water Supply Components 606.1, , , 605.1, NSF * Drinking Water Distillation Appliances NSF * Special Purpose Food Equipment and Devices Appliances , NSF 372 Drinking Water System Components Health Effects Water Supply Components 606.1, , , 605.1, PDI G Testing and Rating Procedure for Hydro Mechanical Grease DWV Components , Interceptors with Appendix of Installation and Maintenance PDI-WH Water Hammer Arresters Water Supply Components , SAE J Automotive Tube , SAE J Type F Clamps for Plumbing Applications Joints ,

15 STANDARDS SRCC Standard OG100- Solar Domestic Hot Water System and Component Test Solar Panels 2006 Protocols SRCC Standard OG Operating Guidelines and Minimum Standards for Certifying Solar Water Heating Solar Water Heating TCNA A * Load Bearing, Bonded, Waterproof Membranes for Thin-Set Miscellaneous , Ceramic Tile and Dimension Stone Installation TCNA A * Specifications for Ceramic Tile Miscellaneous , UL * Household Electric Storage Tank Water Heaters (with revisions Appliances , through April 22, 2009) UL Refrigerant Components and Accessories, Non-Electrical Fitting 604.1, UL * Drinking Water Coolers (with revisions through December Appliances , , 2009) UL Electrically Operated Valves (with revisions through January Valves , , 2010) UL * Waste Disposers Appliances , UL * Electric Heating Appliances (with revisions through Appliances , November 30, 2010) UL * Ice Makers (with revisions through November 19, 2009) Appliances , UL * Test for Surface Burning Characteristics of Building Materials (with revisions through September 13, 2010) Miscellaneous (2), 903.1(2), UL Oil-Fired Boiler Assemblies (with revisions through April 22, 2010) Fuel Gas, Appliances , UL * Oil-Fired Storage Tank Water Heaters (with revisions through Fuel Gas, Appliances , April 22, 2010) UL Household Dishwashers Appliances , UL * Motor-Operated Water Pumps (with revisions through August Appliances , , 2011) UL * Heating, Water Supply, and Power Boilers Electric (with Appliances , revisions through December 4, 2009) UL * Commercial Dishwashers (with revisions through June 23, Appliances , ) UL * Electric Commercial Clothes-Washing Equipment (with revisions through June 16, 2010) Appliances , UL * Electric Water Heaters for Pools and Tubs (with revisions through June 16, 2010) UL Station Inlets and Outlets (with revisions through August 18, 2010) UL * Electric Booster and Commercial Storage Tank Water Heaters (with revisions through December 4, 2009) UL Strength of Body and Hydraulic Pressure Loss Testing of Backflow Special Check Valves (with revisions through March 19, 2010) UL * Fire Tests of Through-Penetration Firestops (with revisions through March 1, 2010) UL * Electric Plumbing Accessories (with revisions through June 25, 2010) UL * Electrical Clothes Washing Machines and Extractors (with revisions through February 16, 2010) WQA S Point-of-Use Low Pressure Reverse Osmosis Drinking Water *ANSI designated as an American National Standard. Appliances, Swimming Pools, Spas, and Hot Tubs , 301.2, USPSHTC Medical Gas , Appliances , Backflow Protection , Miscellaneous , Miscellaneous , Appliances , Appliances ,

16 STANDARDS ABBREVIATIONS IN TABLE 14-1 AHAM Association of Home Appliance Manufacturers, th Street, N.W., Suite 402, Washington DC ANSI American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY ASME American Society of Mechanical Engineers, Three Park Avenue, New York, NY ASSE American Society of Sanitary Engineering, 901 Canterbury, Suite A, Westlake, Ohio ASTM American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA AWS American Welding Society, 550 NW LeJeune Road, Miami, FL AWWA American Water Works Association, 6666 W. Quincy Avenue, Denver, CO CISPI Cast-Iron Soil Pipe Institute, 5959 Shallowford Road, Suite 419, Chattanooga, TN CSA Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada, L4W 5N6. e1 An editorial change since the last revision or reapproval. IAPMO International Association of Plumbing and Mechanical Officials, 5001 E. Philadelphia Street, Ontario, CA ISEA International Safety Equipment Association, 1901 N. Moore Street, Arlington, VA ISO International Organization for Standardization, 1 ch. de la Voie-Creuse, Casa Postale 56, CH-1211 Geneva 20, Switzerland. MSS Manufacturers Standardization Society of the Valve and Industry, 127 Park Street, N.E., Vienna, VA NFPA National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA NSF NSF International, 789 Dixboro Road, Ann Arbor, MI PDI Plumbing and Drainage Institute, 800 Turnpike Street, Suite 300, North Andover, MA SAE Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA TCNA Tile Council of North America, Inc. 100 Clemson Research Blvd., Anderson, SC UMC Uniform Mechanical Code (published by IAPMO). USEC Uniform Solar Energy Code (published by IAPMO). USPSHTC Uniform Swimming Pool, Spa and Hot Tub Code (published by IAPMO). UL Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL WQA Water Quality Association, 4151 Naperville Road, Lisle, IL

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS PRE-PRINT. STANDARD NumBER STANDARD TiTLE APPLiCATioN CHAPTER 14 STANDARDS Note: Referenced sections will be updated before publishing. 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and

More information

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION

CHAPTER 14 REFERENCED STANDARDS TABLE REFERENCED STANDARDS STANDARD NUMBER STANDARD TITLE APPLICATION CHAPTER 14 STANDARDS 1401.0 General. 1401.1 Standards. The standards listed in Table 1401.1 are intended for use in the design, testing, and installation of materials, devices, appliances, and equipment

More information

2012 UPC STANDARDS TASK GROUP

2012 UPC STANDARDS TASK GROUP 2012 UPC STANDARDS TASK GROUP The scope of this task group is to review standard cross-references within the body of the 2009 Uniform Plumbing Code and Table 14-1. The objective is to update standards

More information

STANDARDS TASK GROUP REPORT

STANDARDS TASK GROUP REPORT STANDARDS TASK GROUP REPORT THE SCOPE OF THE STANDARDS TASK GROUP INCLUDES ADDING CROSS- REFERENCES TO TABLE 14-1 AND RECOMMEND WHERE SUCH REFERENCES ARE APPLICABLE TO THE REFERENCED STANDARDS AND TO UPDATE

More information

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS 19.1 REFERENCED STANDARDS Referenced Standards Chapter 19 Table 19.1 lists the standards that are referenced within the requirements of this Code. Table 19.1 shows the designation number of the standard,

More information

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1

CHAPTER 14 MANDATORY REFERENCED STANDARDS TABLE 14-1 CHAPTER 14 MANDATORY REFERENCED STANDARDS AHAM DW-1-92 Household Electric Dishwashers Appliances AHAM DW-2PR-92 Plumbing Requirements for Household Dishwashers Appliances AHAM FWD-1-92 Food Waste Disposers

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES November 21, 2017 Part I: Approved Listing Agencies Part II: Approved Testing

More information

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES

MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES City of Los Angeles Department of Building and Safety MECHANICAL TESTING LABORATORY LIST OF APPROVED LISTING AND TESTING AGENCIES July 25, 2018 Part I: Approved Listing Agencies Part II: Approved Testing

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA

2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA 2016 Uniform Solar Energy & Hydronics Code Technical Committee Meeting IAPMO World Headquarters, Ontario, CA October 26, 2016 AGENDA I. Call to Order II. Chairman Comments III. Announcements IV. Self Introductions

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications 1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments

TABLE OF CONTENTS. Tentative Agenda. Tentative Order of Discussion. A2L Task Group Report III. Uniform Mechanical Code Change Public Comments TABLE OF CONTENTS I Tentative Agenda II Tentative Order of Discussion III A2L Task Group Report IV Uniform Mechanical Code Change Public Comments 2017 Uniform Mechanical Code Technical Committee Meetings

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems CHAPTER 15 REFERENCED STANDARDS SECTION MC 1501 GENERAL 1501.1 General. This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018, STANDARDS Chapter 17, Part II CHAPTER 17 STANDARDS 1701.0 Scope Part I of this chapter covers standards that are hereby declared to be part of this code. Part II of this chapter lists standards which relate

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY a. Only potable water shall be supplied to plumbing fixtures used for drinking, bathing, culinary use or the processing of food, medical or pharmaceutical

More information

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type. PART 1 - GENERAL 1.1 Toilet rooms and utility rooms to have floor drains at lowest point. 1.2 Utilize Exposed Flushometers. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point. PART 1 - GENERAL 1.01 Toilet rooms and utility rooms to have floor drains at lowest point. 1.02 Utilize Exposed Flushometers. 1.03 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

More information

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS AG AVB PVB DCVA PA 1 Abattoir (slaughter house) 2 Air compressor oil cooler 3 Agricultural chemicals (sprayers 4 Animal watering 5 Apartment building (within the scope of Part 3 of the Ontario Building

More information

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS). PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

Committee Input No. 5-NFPA [ Chapter 14 ]

Committee Input No. 5-NFPA [ Chapter 14 ] http://submittalsnfpaorg/terraviewweb/contentfetcher?commentpara Committee Input No 5-NFPA 501-2015 [ Chapter 14 ] Chapter 14 Referenced Referenced Publications 14 1 General 1 General The documents or

More information

SECTION BASIC MATERIALS AND METHODS

SECTION BASIC MATERIALS AND METHODS SECTION 15050 BASIC MATERIALS AND METHODS PART 1 1.1 SECTION INCLUDES A. General Conditions B. Supplementary Conditions C. Division 1 D. Mechanical basic requirements E. Electric Motors F. Pipe, Valve,

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

CHAPTER 15 REFERENCED STANDARDS

CHAPTER 15 REFERENCED STANDARDS CHAPTER 15 REFERENCED STANDARDS This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the

More information

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS 22 00 70 (November 2011) Change 1-08/17 ----------------------------- Preparing Activity: USACE Superseding UFGS 22 00 70 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

A. Section Joint Sealants: Seal fixtures to walls and floors.

A. Section Joint Sealants: Seal fixtures to walls and floors. SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following: 1. Hot-water

More information

WATERSTONE ASSISTED LIVING AND MEMORY CARE

WATERSTONE ASSISTED LIVING AND MEMORY CARE DOMESTIC WATER PIPING SPECIALTIES BATON ROUGE, LOUISIANA SECTION 22 11 19 SECTION 22 11 19 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

1. Division 22 Section Emergency Plumbing Fixtures. 2. Division 22 Section Drinking Fountains and Water Coolers. Page 224000-1 SECTION 224000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

$0.98 $ KITCHEN SINK STRAINER, 3-1/2 x BATH TUB DRAIN, 1-15/16 x 2-3/4 x $ $1.89 *s are Subject to Change without Notice.* WASHERS Rubber Beveled 5-1915 CLOSET, 3/8" O.D. TUBE $0.20 5-1916 CLOSET, 1/2" O.D. TUBE $0.20 5-1917 LAVATORY, 1/2" TALL x 3/8" O.D. $0.20 TUBE 5-1849 LAVATORY,

More information

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015 1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

NFPA 54 UPDATE. Paul Cabot American Gas Association

NFPA 54 UPDATE. Paul Cabot American Gas Association NFPA 54 UPDATE Paul Cabot American Gas Association PRESENTATION TOPICS Summary Listing Schedule Revisions Definitions/General Piping Appliances and Appliance Installation Venting 2015 Edition Revision

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

FIXTURES, FAUCETS AND FIXTURE FITTINGS

FIXTURES, FAUCETS AND FIXTURE FITTINGS CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL 401.1 Scope. This chapter shall govern the materials, design and installation of plumbing fixtures, faucets and fixture fittings in

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub. CHAPTER 2 DEFINITIONS 201.0 General. For the purpose of this code, the following terms have the meanings indicated in this chapter. No attempt is made to define ordinary words which are used in accordance

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 TEi-LISTING SERVICES 3455 S. 500 W. Salt Lake City, UT 84115 Mrs. Alona MacGregor (Authorized Representative) Phone: 801 262 1868 Email: alona@tei-test.com

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

8501 E. Pleasant Valley Rd. Cleveland, OH 44131

8501 E. Pleasant Valley Rd. Cleveland, OH 44131 IAS Accreditation Number Company Name Address Contact Name TL-266 8501 E. Pleasant Valley Rd. Cleveland, OH 44131 Benjamin Barker Manager, Accreditations Telephone (416)747-4013 Effective Date of Scope

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

Planting Irrigation

Planting Irrigation University of New Hampshire University of New Hampshire Scholars' Repository Division 32 Exterior Improvements Chapter 5 Technical Construction and Renovation Standards 1-25-2013 328400 - Planting Irrigation

More information