LIQUID ELIMINATORS/ FLOAT TYPE LIQUID DRAINERS
|
|
- Joel George
- 5 years ago
- Views:
Transcription
1 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS GENERL FETURES Working Principle The allows the discharge of liquids from the gas and air lines. Fluid drain is happen with a float and the associated lever arm. The air or other gases in the device start to fill up in the liquid drainer body. The air and gases on the float allow the orifice to be closed by applying a downward force. The air and gases in the body cool down after a while and consequently start to condense. The resulting water implements a force in the upward direction to allow the float to open also the lever and its associated ball orifice. Thus, the water is discharged. When the air come again to it close the orifice. Sealing against air is ensured. This cycle continues automatically. Connection: Threaded, Flanged Connection Type: Vertically, Horizontally Nominal Diameter: DN15 (1/2 ) - DN25 (1 ) Pressure: Max. 16 bar Working Temperature: Max. Working Temp. 250 C pplications: - Compressors - Heat exchangers - Heating batteries - Tanks - Separators - Packets - collectors - Drying rollers Drain Capacity Drain Capacities Presssure Difference bar (x100= kpa) DIN EN 250 C NSI
2 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS Installation The can be installed horizontally and vertically. The pipeline must be sloped to maintain fluid flow. If there is a large amount of condensate (especially in air tanks) it can lock because the inside of the body will fill with a lot of fluid and will float above the float. s a result, a by-pass line must be made before the air line enters the liquid drainers. Bypass line must be done over the liquid drainers' body for horizontal installation. Δp Max. Maximum differential pressure due to the density of the liquid DENSITY 1 0,9 0,8 0,7 min 0,6 Δp Max. Pressure Difference Δp Min. Pressure Difference 0,1 bar FLNGED THREDED D1 D C D k g b D1 C L L B Dia. ØD Øk Øg b DIMETERS Flanged (mm) Holes' Dia. B C ØD1 L and number DN Ø14x , ,6 DN Ø14x , ,1 DN Ø14x , ,6 Weight (kg) Dia. Threaded (mm) B C ØD ØD1 L Weight (kg) 1/2" , ,5 3/4" , ,5 1" , ,3 ll measurements in the table are given in mm. ll technical arrangements and changes to be made in the production process are the property of yvaz.
3 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS PRODUCT STRUCTURE PRT LIST No PRT NME MTERIL 1 Cover GGG 40.3 Cast Iron 2 Seat Gasket ISI 304 Stainless Steel 3 Float Seat ISI 304 Stainless Steel 4 Float Handle Bearings ISI 304 Stainless Steel 5 Bolt.K.B. M5 ISI 304 Stainless Steel 6 Spring Spring Iron 7 Float Stem ISI 304 Stainless Steel 8 Float Handle ISI 304 Stainless Steel 9 Float ISI 304 Stainless Steel 10 Bolt.K.B. M5 ISI 304 Stainless Steel 11 Washer ISI 304 Stainless Steel 12 Bolt.K.B. M12 ISI 304 Stainless Steel 13 Cover Gasket %94 Pure Graphite 14 Body GGG 40.3 Cast Iron 15 Bolt.K.B. M /4" ISI 304 Stainless Steel
4 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS IR SPERTOR PPLICTION SMPLE Seperator Water IR TNK PPLICTION SMPLE Safety Valve Manometer Tank Water
5 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS IR COLLECTOR PPLICTION SMPLE Manometer 1/70 Collector Slope should be this way. Drianage Water IR PCKET SMPLE Water Not: packets must be applied on air lines at certain distance and conditions.
6 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS IR PCKET SMPLE-2 END OF THE LINE PPLICTION Not: liquid drainer must be placed at all rising points in the air line. Water Non contractual document - Reproduction forbidden without prior authorization 1/70 Slope should be this way. Ball Valve Process 1 Process 2 Note: s shown in the application example, after the process 2, the line end application should be done because the line is finished.
7 LIQUID ELIMINTORS/ FLOT TYPE LIQUID DRINERS HED OFFICE - FCTORY tatürk Sanayi Bölgesi Hadımköy Mahallesi Mustafa İnan Caddesi No: 44 rnavutköy - İSTNBUL Tel: (pbx) Fax: info@ayvaz.com Caserta/Italy Tel: rmolaro@ayvaz.com Moscow/Russia Tel: ayvazrus@ayvaz.com Viernheim/Germany Tel: germany@ayvaz.com Kiev/Ukraine Tel: info@ayvaz.com.ua Warsaw/Poland Tel: tricorr@tricorr.eu Dubai/U..E Tel: mideast@ayvaz.com Cixi City/China Tel: info@ayvazchina.com Kazakhstan Tel: +7 (701) (533) celyas@ayvaz.com Isperih/Bulgaria Tel: o ffice@ayvaz-n.eu Belgrad/Serbia Tel: yakbiyik@ayvaz.com
STEAM EQUIPMENT 4
STEAM EQUIPMENT info@ayvaz.com www.ayvaz.com 4 (11-12-13-14--28)MK-16 BELLOW SEALED VALVE (1)ASD DEAERATOR TANK SECTION (FEED WATER, BOILER COLLECTOR (HEADER) (16-21-22-27)V3-F STAINLESS STEEL BALL VALVE
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationCONDANSATE TRANSFER PUMP
CONDANSATE TRANSFER PUMP info@ayvaz.com www.ayvaz.com CONDANSATE TRANSFER PUMP Package Type Condansate Transfer Pump Ayvaz condensate pump is a system which is collecting how condensate and usually pump
More informationSOLAR SYSTEM. We follow the sun.
SOLAR SYSTEM We follow the sun. www.ayvaz.com AYVAZ SOLAR SYSTEMS COMPLETE SOLAR CONNECTION SET Ayvaz offers a complete set to connect all mechanic components of solar systems to each other and the rest
More informationMIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES
A MEMBER OF EURO-QUALIFLEX MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES MIG-GAS MIG-SU Scan this QR Code www.ayvaz.com MIG-GAS (NATURAL GAS CONNECTIONS) Application Areas Natural gas applications Kitchen
More informationFT14 Ball Float Steam Trap (Screwed)
Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals
More informationSpecialty Products SUCTION/MIXING TEES
Specialty Products STINLESS STEEL CHECK VLVES Watson McDaniel Check Valves are available in all 316 SS construction in 1 2 thru 3 sizes and were specifically designed to handle the difficult environments
More informationUNIVERSAL STYLE STEAM TRAPS WU450 Series
Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,
More informationNON-SLAM DYNAMIC ARV FAF 7330
PRODUCTION STANDARTS DN50 DN250 PN 10-16 Design EN 1074-4 End Connection EN 1092-2 / ISO 7005-2 Marking EN 19 Tests EN 12266 Corrosion Protection Industrial Epoxy Features y Non-Slam Dynamic ARV to be
More informationLiquid Drainers LIQUID DRAINERS
Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG
More informationFT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")
Page 1 of TI-S0- ST Issue and HC ISO 9001 SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and ") Cert. No. LRQ 09300 HC 1" 1¼" -C 1½" and " Description The and HC are iron bodied ball float steam traps
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationPRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS
OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux
More informationSelf-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2
Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43- Type 43-2 Application Regulators for district heating supply systems, heat generators, heat exchangers, and other building
More informationPT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.
PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationInverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment
Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation.
More informationThe Expertise for Components
Self Actuated Thermostatic Valves The Expertise for Components MVA Mess- und Verfahrenstechnik GmbH Am Kirchenhölzl 7 D-82166 Gräfelfing Fon: +49/89-85 83 69-0 Fax: +49/89-85 83 69-70 info@mva-messvt.de
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationFT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS
STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationModel: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationDISCALDIRT deaerator-dirt separator
DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationModel: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100
1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead
More information(Alarm Valve) & ' ( ()& * +,, & +-,. /0-
(Alarm Valve). 8123-52 กก ก . 8123-52 1. 1.1 กก ก กก 1.2 1.2.1 ก (Alarm Valve) ก ก (Alarm Valve) (Alarm Valve) ก ก ก ก กก 1.2.2 ก (Alarm Valve) 25 (1 ) 300 (12 ) 1.2.3 ก (Alarm Valve) กก 2. กกก ก (Solid
More informationESCO. Committed. Group of Companies. to help conserve Steam Energy
Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationResidential & Commercial Water Booster Systems Frequency Controlled Water Booster Systems
Residential & Commercial Water Booster Systems Frequency Controlled Water Booster Systems Experience With our R&D, production, and installation experience of more than 35 years in the pump technologies
More informationSteam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat
s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting
More informationMFP14 Automatic pumps. for condensate and other industrial fluids
MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationCERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.
CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry
More informationAPT and APT14 Automatic Pump Traps. for effective condensate drainage and removal
APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation
More informationBASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology
BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP...world leaders in heat transfer technology The Basic Operation of Type T and TC Separators Basco Type T and TC Separators are designed to remove entrained
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationCondensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:
www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system
More informationModel: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationParts and Service Manual
Section II Parts and Service Manual (70241A) CLARKE TECHNOLOGY Operator's Manual - MINI MAX Page -29- Frame and Front Cover Assembly Drawing 2/01 Page -30- CLARKE TECHNOLOGY Operator's Manual -MINI MAX
More information1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide
1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationCERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.
CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationStokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing
Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020
More informationFLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)
LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam
More informationCALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function
Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature
More informationPumps. Heating Drinking water Solar Geothermy Condensate
Pumps eating Drinking water Solar Geothermy Condensate + CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known OEM customers,
More informationSECTION REFRIGERANT PIPING
SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDisc Type Steam Trap TSD-42
Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat
More informationPRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.
PRODUCTS Expansion Joints Fire Fighting Equipments Flexible Metal Hoses Steam Equipments Valves Level Control Insulation Solutions VALVES FLEXIBLE METAL HOSES EXPANSION JOINTS LEVEL CONTROL EQUIPMENTS
More information8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.
8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature
More informationSMITH STAINLESS FLOOR DRAIN SERIES - CAST
SMITH STINLESS FLOOR DRIN SERIES - CST 7 Round General Purpose Floor Drain with djustable Strainer Head for Light Duty Use Function: General service floor drain for use in finished areas where foot traffic
More information~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)
Date: 05 May 2009 Doc. 002190-2 TECHNICAL DATA 6543521 UNIT 2L, CONNECTION UPWARDS Mini-check Straight connection DN50 Rubber bend DN40 Connection DN40 83 ~195 35 Max. 3m ~256 Ø90 Evac Noback OUTLET Discharge
More informationTechnical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm
HEGA Horizontal Multistage Pump Brief Introduction HEGAHorizontal Multistage Pump is the new multistage product series, the excellent hydraulic performance and structure of which have enabled low cost
More informationSTEAM ANGLE RADIATOR VALVE HOT WATER ANGLE VALVES DIMENSIONS IN INCHES DIMENSIONS IN INCHES
NGLE RDITOR VLVE ST OR T-431 LEGEND T-431 steam angle radiator valves are constructed of heavy duty bronze. They have a screwed bonnet, rising stem and composition disc. LEGEND T-431Y (Yellow rass) is
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationVALVES SECTION 15100
VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common
More informationECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT
ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com
More informationRefrigerant Valves/Accessories
Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating
More informationVM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG
VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL
More informationCompressed air preparation Compressed air storage Moisture management. Catalog #1
Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.
More informationGroup Exercise Lifecycle Bike Base GEC-ALLLX-02
Group Exercise Lifecycle Bike Base GEC-ALLLX-0 Parts Manual /9/07 5:53:9 PM GEC-ALLLX-0 - GROUP EXERCISE Table of Contents Base Electronics...3 Cable Management... Drive System - Drive Belt, Crankshaft,
More informationPamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries
Pamphlet M00- JAD / JA Series / G8 AIR & DRAIN TRAPS TATSU SSVG / JAHSeries Free Technology AIR TRAPS For Air In today's world of automatation, compressed air is used in many different industries including
More informationDiscontinued Product
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Victaulic Series 759 alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationSERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.
Temperature Control Units Water & Oil 0-00 F Portable Chillers ir & Water-Cooled 0-70 F Central Chillers ir & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-0 gallons
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:
More informationInverted bucket steam traps Type OKZ PN6/PN16
-TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.
More informationCirculation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate
Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate + CATALOGUE ALM produces highly-efficient heating circulation pumps ALM has been successfully developing
More informationPORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES
PORTABLE HYDRANT PN1 1A; 2A; 1B; 2B; 1C; 2C TYPES HP 1 page 1A (type 1) (type 2) In water supply systems for fire extinguishing or other necessities. - Design... in conformity with STAS 698; - Nominal
More informationYARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260
SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat
More informationThe right trap for the right application.
The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application
More informationCoolPro COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.
COMPRESSED IR & GS TRETMENT CoolPro Compressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency. The ftercooler market has gone through
More informationWSSCV Check Valve Stainless Steel 500 1/2-3 NPT, SW 334. SVB Safety Relief Valve Bronze 250 1/2-2 1 /2 NPT 336
ncillary Products to support your Steam and Hydronic Systems. Table of Contents Model/Series Product Body Material PMO (PSIG) Size Connection Page No. WSSCV Check Valve Stainless Steel 500 1/2-3 NPT, SW
More informationTHERMODYNAMIC STEAM TRAP
THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,
More informationInstallation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50
Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationProduct. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits
Engineering Products for the Steam Industry Since 985 Product Catalog Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Add Efficiency To Your Steam Investment...
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationPumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert
Pumps eating Drinking water Solar Geothermy Condensate BAFA gefördert CATALOGUE The Company For more than years, ALM has developed and produced motors and pumps. In the beginning exclusively for well-known
More informationEW171 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW171 Series Woltman Bulk Water Meters DN50 300 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA EW171, DN50 Contents... 1 General... 2 Application... 2 Features... 2 Design... 2 Materials...
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationSelfpriming Centrifugal Pumps. Type HZS/HZSA
Selfpriming Centrifugal Pumps Type HZS/HZSA General The selfpriming multistage DICKOW-centrifugal pump is designed for handling hydrocarbons and other volatile liquids. The HZS-type is used in tank farms,
More informationDivision 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL
Division 23 - HVAC 090070 Switzerland Beallsville K-12 Section 23 21 13 HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the
More informationSpecifications of MULTIFIRE burners
-.-6 High temperature burners - MULTIFIRE Specifications of MULTIFIRE burners Gas firing Typical burner data Fuel: natural gas at 60 F with 000 tu/ft³ (st) HHV - sg = 0.6 [] Combustion air: 60 F - % O
More informationPamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationThermostatic Control Valves
Thermostatic ontrol Valves Model Typical applications Lubricating oil temperature control Jacket temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications oiler inlet
More informationNEOTeCHA Reactor Sampling Type PV
A safe and reliable sampling device to meet the demands of the chemical and pharmaceutical industry Features General applications To take a sample from reactors or vessels containing: poisoned media s
More informationVacuum Saving Valve. ZP2V Series. With One-touch fitting type available!
Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding
More informationModel MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)
Model MBEC-14 (SIN R6932) Features 1. Designed to be installed on piping that is supported by the primary structure, not the purlins. 2. Provides Extended Coverage Ordinary & Extra Hazard protection to
More informationTemperature controller for steam (PN 25) AVT / VGS - external thread
Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic
More informationTHERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION
THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationFLANGE-MOUNT CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES GV6 SECTION E PAGE ISSUED /0 REPLACES /0 FLANGE-MOUNT CENTRIFUGAL PUMPS Idel for OEM applications
More informationPamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More information