Cassette type. 1. Summary. Cassette type NOTE MODEL. CE STANDARD 1Ph V 50Hz R22 KF-50TW/A1 KFR-50TW/A1 KF-50TW/NA1 KFR-50TW/NA1

Size: px
Start display at page:

Download "Cassette type. 1. Summary. Cassette type NOTE MODEL. CE STANDARD 1Ph V 50Hz R22 KF-50TW/A1 KFR-50TW/A1 KF-50TW/NA1 KFR-50TW/NA1"

Transcription

1 Cassette type 1. Summary figure 1 MODEL NOTE KF-50TW/A1 KFR-50TW/A1 CE STANDARD 1Ph V 50Hz R22 KF-50TW/NA1 KFR-50TW/NA1 CE STANDARD 1Ph V 50Hz R407C -1-

2 figure 2 MODEL NOTE KF-70TW/B1(7031T1) KFR-70TW/B1(7051T1) CE STANDARD 1Ph V 50Hz R22 KF-70TW/B1(7031T1)N KFR-70TW/B1(7041T1)N CE STANDARD 1Ph V 50Hz R407C KF-70TW/B(7031T)N KFR-70TW/B(7041T)N CE STANDARD 3Ph V 50Hz R407C KF-70TW/B(7031T)A KFR-70TW/B(7041T)A 3Ph V 50Hz R22 GSK24-22L/A GSK24-22R/A CE STANDARD 1Ph 220V 60Hz R22-3-

3 figure 3 MODEL NOTE KF-120TW/B(1231T)N KFR-120TW/B(1241T)N CE STANDARD 3Ph V 50Hz R407C KF-120TW/B(1231T)C KFR-120TW/B(1251T)B 3Ph V 50Hz R22 KF-120TW/B(1231T)B KFR-120TW/B(1241T)B CE STANDARD 3Ph V 50Hz R22 GSK41-22L/A GSK41-22R/A 3Ph 220V 60Hz R22-5-

4 2. Technical specifications Table 1 Model Function Power supply Capacity W Rated input (W) Rated current (A) Air flow (m 3 /h) Dehumidifying volume(l/h) Model Motor fan speed(r/min) KF-50TW/A1 KFR-50TW/A1 KF-50TW/NA1 KFR-50TW/NA1 Cooling Cooling Heating Cooling 1PH V 50Hz Cooling Heating KF-50T/A1 KFR-50T/A1 KF-50T/NA1 KFR-50T/NA1 620/720/820 Indoor unit Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(m 2 ) Swing motor Input power Control method Fuse (A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Height (mm) Depth (mm) Panel Main body 11 Centrifugal fan-1 283mm/148mm Aluminum fin-copper tube 2/ MP35BA 2W/12V DC Remote control Control Board-3.15; Transformer

5 Table 1 continue Model KF-50TW/A1 KFR-50TW/A1 KF-50TW/NA1 KFR-50TW/NA1 Outdoor unit Connection pipe Model Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Fan motor Compressor Working area(m 3 ) Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Outl ine Model Output power (W) Fan motor speed (rpm) Quantity Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid Diameter pipe(mm) Gas pipe(mm) Standard length(m) Max. height Distance (m) length KF-50W/tA KFR-50W/tA1 1900/ KF-50W/tNA Capillary PSC Build-in Aluminum fin-copper tube 2/ KFR-50W/tNA1 2090/ /10.2 FW60D FW60B FW60D FW60B /620 Rotary 2V34S225AUA 1 Axial flow fan/1 450 Auto defrost R22 R407C Rotary C-2RN170H5U /620/ / /620/380 The technical data are subject to change without notice.please refer to the nameplate of the unit. -8-

6 Table 2 Model Function Power supply Capacity Rated input (W) Rated current (A) Air flow (m 3 /h) Kcal/h Btu/h W Electric heater power (W) Dehumidifying volume(l/h) KF-70TW/B1 (7031T1)N Cooling KFR-70TW/B1 KF-70TW/B1 (7041T1)N (7031T1) Cooling Heating Cooling 1PH, V 50Hz KFR-70TW/B1 (7051T1) Cooling Heating \ \ Model KF-70T/B1 (7031T1)N KFR-70T/B1 (7041T1)N KF-70T/B1 (7031T1) KFR-70T/B1 (7051T1) Indoor unit Motor fan speed(r/min) Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(mm 2 ) Swing motor Input power-speed Control method Fuse(A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Height (mm) Depth (mm) Panel Main body 600/550/ /550/500 35W Centrifugal fan-1 450mm/140mm Aluminum fin-copper tube 2/1.5 3/1.5 SM008 3W-2.5r/min Remote control Controller 3.15A Transformer 0.2A 450mm/140mm 1980x x /1.5-9-

7 Table 2 continue Model Outdoor unit Connection pipe Model Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Working area (mm mm) Model Output power (W) Fan motor speed (rpm) Quantity Outline Fan motor Compressor Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid Diameter pipe(mm) Gas pipe(mm) Standard length(m) Max. height Distance (m) length KF-70TW/B1 (7031T1)N KF-70W/tB1N KFR-70TW/B1 (7041T1)N KF-70TW/B1 (7031T1) KFR-70TW/B1 (7051T1) KFR-70W/tB1N KF-70W/tB1 KFR-70W/tB1 2610/ / / /11.3 Capillary Reciprocating AWG5532EVA AWG5532EXC CSR Inner 82 Rotary C-RN220H5B CSR Aluminum fin-copper tube 2/ x600 FW60D FW60T FW60D FW60S / /620/ / /600/ Axial flow fan/1 450 Auto defrost R407C R /8" 16 5/8" The technical data are subject to change without notice.please refer to the nameplate of the unit. -10-

8 Table 3 Model Function Power supply Capacity(W) Rated input (W) Rated current (A) Air flow (m 3 /h) Kcal/h Btu/h W KF-70TW/B (7031T)N Cooling KFR-70TW/B KF-70TW/B (7041T)N (7031T)A Cooling Heating Cooling 3Ph, V 50Hz KFR-70TW/B (7041T)A Cooling Heating Dehumidifying volume(l/h) 4.0 Model KF-70T/B (7031T)N KFR-70T/B (7041T)N KF-70T/B (7031T)A KFR-70T/B (7041T)A Motor fan speed(r/min) 600/550/500 Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) 35W Centrifugal fan-1 450mm/112mm Aluminum fin-copper tube 2/ mm/140mm Indoor unit Working area(m 2 ) Swing motor Input power-speed Control method Fuse(A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Depth (mm) Height (mm) Panel Main body 0.34 SM008 3W-2.5r/min Remote control Controller 3.15A Transformer 0.2A

9 Table 3 Continue Model KF-70TW/B (7031T)N KFR-70TW/B (7041T)N KF-70TW/B (7031T)A KFR-70TW/B (7041T)A Model KF-70W/tBN KFR-70W/tBN KF-70W/tBA KFR-70W/tBA Outdoor unit Connection pipe Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Outline Fan motor Compressor Working area (mm mm) Model Output power (W) Fan motor speed (rpm) Quantity Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid Diameter pipe(mm) Gas pipe(mm) Standard length(m) height Max.Distance length Rotary C-RN243H8A 2630/ /4.6 Capillary IR Inner Aluminum fin-copper tube 2/ x / /4.6 FW60D FW60T FW60D FW60T / /620/ / /620/600 1 Axial flow fan/1 450 Auto defrost R407C R /8" 16 5/8" Reciprocating AVA5535EXG The technical data are subject to change without notice.please refer to the nameplate of the unit. -12-

10 Table 4 Model Function Power supply Capacity(W) W Rated input (W) Rated current (A) Air flow (m 3 /h) Dehumidifying volume(l/h) Model Motor fan speed(r/min) GSK24-22L/A Cooling GSK24-22L/A(I) Cooling 1Ph,220V 60Hz /550/500 GSK24-22R/A 2750 GSK24-22R/A(I) Heating 7500 Indoor unit Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(m 2 ) Swing motor Input power-speed Control method Fuse(A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Height (mm) Depth (mm) Panel Main body 35 Centrifugal fan-1 450/140 Aluminum foil fin-copper tube 2/ SM008 3W/2.5r/min Remote control Controller 3.15A Transformer 0.2A

11 Table 4 Continue Model Model GSK24-22L/A GSK24-22L/A(O) GSK24-22R/A GSK24-22R/A(O) Outdoor unit Connection pipe Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Outline Fan motor Compressor Working area (m 2 ) Model Output power (W) Fan motor speed (rpm) Quantity Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid Diameter pipe(mm) Gas pipe(mm) Standard length(m) height Max.Distance length FW60H 780/620 Capillary Scroll AWG5530EXN PSC Build-in Aluminum fin-copper tube 2/ Axial Auto defrost R /8" 16 5/8" / /13 FW60C 780/620/600 The technical data are subject to change without notice.please refer to the nameplate of the unit. -14-

12 Table 5 Model Function Power supply Capacity(W) Rated input (W) Rated current (A) Air flow (m 3 /h) W Dehumidifying volume(l/h) KF-120TW/B (1231T)C Cooling KFR-120TW/B KF-120TW/B (1251T)B (1231T)N Cooling Heating Cooling 3Ph,380~400V~50Hz KFR-120TW/B (1241T)N Cooling Heating Model KF-120T/B (1231T)C KFR-120T/B (1251T)B KF-120T/B (1231T)N KFR-120T/B (1241T)N Indoor unit Motor fan speed(r/min) Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(m 2 ) Swing motor Input power-speed Control method Fuse(A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Depth (mm) Height (mm) Panel Main body 610/560/ /560/510 50W 50W Centrifugal fan-1 Centrifugal fan-2 502mm/160mm 502mm/160mm Aluminum foil fin-copper tube 3/1.5 3/ SM008 3W-2.5r/min Remote control Controller 3.15A Transformer 0.2A

13 Table 5 Continue Model KF-120TW/B (1231T)C KFR-120TW/B (1251T)B KF-120TW/B (1231T)N KFR-120TW/B (1241T)N Model KF-120W/tBC KFR-120W/tBB KF-120W/tBN KFR-120W/tBN Outdoor unit Connection pipe Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Outline Fan motor Compressor Working area (m 2 ) Model Output power (W) Fan motor speed (rpm) Quantity Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid pipe(mm) Diameter Gas pipe(mm) Standard length(m) height Max.Distance length AGC5561EXG Reciprocating / / Aluminum fin-copper tube 2/ / /7.0 FW68D FW68T FW68D FW68A / /740/ / /350/200 2 Axial flow fan/2 2 Axial flow fan/2 450 Auto defrost R22 R407C /2 19 3/4 C-SB373H8A Capillary IR Inner Scroll C-SBN373H8A /2 19 3/4 The technical data are subject to change without notice.please refer to the nameplate of the unit. -16-

14 Table 6 Model Function Power supply Capacity(W) Rated input (W) Rated current (A) Air flow (m 3 /h) W Dehumidifying volume(l/h) KF-120TW/B (1231T)B Cooling KFR-120TW/B GSK41-22L/A (1241T)B Cooling Heating Cooling 3Ph, V~50Hz Cooling GSK41-22R/A Heating Model KF-120T/B (1231T)B KFR-120T/B (1241T)B GSK41-22L/A(I) GSK41-22R/A(I) Indoor unit Motor fan speed(r/min) Output power(w) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(m 2 ) Swing motor Input power-speed Control method Fuse(A) Work capacitor( F) Noise(dB(A)) Outline panel Main body Net weight(kg) Width (mm) Height (mm) Depth (mm) Width (mm) Depth (mm) Height (mm) Panel Main body 610/560/ /660/610 50W 60W Centrifugal fan-1 Centrifugal fan-1 502mm/160mm 502mm/160mm Aluminum foil fin-copper tube 3/1.5 2/ SM008 3W-2.5r/min Remote control Controller 3.15A Transformer 0.2A

15 Table 6 Continue Model KF-120TW/B (1231T)B KFR-120TW/B (1241T)B GSK41-22L/A GSK41-22R/A Model KF-120W/tBB KFR-120W/tBB GSK41-22L/A(O) GSK41-22R/A(O) Outdoor unit Connection pipe Input power W Current A Throttling method type model Starting method Overload protector L.R.A A Working temp. ( ) Input power W Condenser Row-fin diatance(mm) Outline Fan motor Compressor Working area (m 2 ) Model Output power (W) Fan motor speed (rpm) Quantity Fan type/piece Fan diameter (mm) Defrost method Noise [db(a)] Width (mm) height (mm) depth (mm) Net weight (kg) Refrigerant Refrigerant charge(kg) Liquid pipe(mm) Diameter Gas pipe(mm) Standard length(m) height Max.Distance length Reciprocating C-SB373H8A / / Aluminum fin-copper tube 2/ FW68D FW68T FW68K / /740/ /640 2 Axial flow fan/2 450 Auto defrost 2 Axial flow fan/ R /2 19 3/4 Capillary IR Inner Scroll C-SB303H3B /4300(6400) 13.3/ /2 19 3/4 FW68E 840/740/640 The technical data are subject to change without notice.please refer to the nameplate of the unit. -18-

16 3. Outlines and dimensions of indoor unit For 50 model unit:mm above 1500 above 1500 above 1800 unit:mm figure 4-19-

17 For others H1 950 Model H GSK24-22L(R)/A GSK41-22L(R)/A 355 unit:mm Model H H2 GSK24-22L(R)/A GSK41-22L(R)/A above 1500 above 1500 above 1800 unit:mm figure 5-20-

18 4. Outlines and dimensions of outdoor unit For 50,70 and GSK24-22L(R)/A model H Model H(mm) unit:mm GSK24-22L(R)/A above 500mm above 500mm above 1000mm above 1000mm above 200mm block handle gas valve wire hole liquid valve front grill air outlet above 1000mm above 1000mm Ground figure 6-21-

19 For 120 and GSK41-22L(R)/A model 1250 handle gas valve wire hole liquid valve front grill figure 7-22-

20 (Blank) -23-

21 5. Explosive view and spare parts list of indoor panel For 50 model figure 8-24-

22 Table 7 No Description Part No T02 Qty 1 Filter Right Clamp Big Gear Little Gear Cover of Air Guider Synchronous Motor MP35BA MP35BA Universal Joint Connecting Lever Inner Conner Cover I Inner Conner Cover II Front Panel Receiver PCB KJ Receiving Window Gimbal Left Clamp Air Inlet Grille The data are subject to change without notice. -25-

23 For others figure 9-26-

24 Table 8 No Description Part No T01 Qty 1 Motor Cover Inner Conner Cover IV IV Synchronous Motor SM Motor Holder Pin 3X Air Outlet Foam Front Panel Connecting Lever Inner Conner Cover III Hanging Ring Filter Fixing Plate of Net Hook Net Hook Right Clamp Air Inlet Grille Receiving Window Receiver PCB Outer Conner Cover II Cover of Receiving Window Outer Conner Cover I Left Clamp Spring Inner Conner Cover II Air Guider Assy Crank Positioning Holder Universal Joint Gimbal inner conner cover I The data are subject to change without notice. -27-

25 6. Explosive view and spare parts list of indoor unit For 50 model figure

26 -29- Table 9 Part No No Description KF- 50T/A1 KFR- 50T/A1 KF- 50T/NA1 KFR- 50T/NA1 Qty 1 Tube-exit Plate Front Side Plate Motor Gasket Right Side plate Basing Plate Motor FN11T FN11T Motor Support Fixer Nut with Washer M Evaporator Left Plate Centifugal Fan Evaporator Left Plate Cable-cross Loop Cable-cross plate Evaporator Assy Evap Connection Water Tray Screw Wire Clamp Terminal board T360C Transformer SC28B Remote Controller Y512(GREE) Electric Box Cover PCB 6251J 6251J \ \ 1 PCB 6253J 6253J \ \ Electric Box Capacitor CBB61 2.5uF/450VAC CBB61 2.5uF/450VAC Water Tray foam Rubber Plug Evaporator Support Evaporator Right Plate Pump Drainpipe Water Level Switch Pump Support Pump Gasket Pump Gasket Pump PSB-7 PSB Motor Bolt Left Side Plate Bolt M6X Body Fixing Plate The data are subject to change without notice.

27 For others figure

28 Table 10 Part No No Description KF-70T/B KFR-70T/B KF-70T/B1 KFR-70T/B1 KF-120T/B KFR-120T/B Qty (7031T)N (7041T)N (7031T1)N (7041T1)N (1231T)N (1241T)N 1 Tube-exit Plate Body Fixing Plate Front Side Plate Left Side Plate \ \ 1 Left Side Plate \ \ \ \ Busing plate Rear Side Plate \ \ 1 Rear Side Plate \ \ \ \ Bottom Foam Motor Gasket Bolt Motor Support Motor FN35D (FN35B) \ \ 1 Motor FN50T (FN50T) \ \ \ \ Centifugal Fan \ \ 1 Centifugal Fan \ \ \ \ Evap Connection Cable-cross Loop Evaporator Assy \ \ \ \ 1 15 Evaporator Assy \ \ \ \ 1 Evaporator Assy \ \ \ \ Water Tray Screw Electric Plate Flow-guide Loop Electric Box Insulated Clamp B Terminal Board T360B Transformer (SC28B1) Electric Box Cover I I Electric Box Cover II I I PCB 6051 J 6051 J \ \ \ 1 PCB 6053 J 6053 J \ \ \ Capacitor 3.5uF 3.5uF \ \ 1 Capacitor 4.5uF 4.5uF \ \ \ \ Rubber Plug Drainage Plastic Evap Support Nut with Washer M Fixer Water Pump Pump Gasket Pump Support Water Level Switch Pump Drainpipe Auxiliary Heater \ \ \ \ \ \ \ 39 Right Side Plate \ \ 1 Right Side Plate \ \ \ \

29 Table 10 continue Part No No Description KF-70T/B KFR-70T/B KF-70T/B1 KFR-70T/B1 KF-120T/B KFR-120T/B Qty (7031T)N (7041T)N (7031T1)N (7041T1)N (1231T)N (1241T)N 40 Cable-cross Block Pump Cover Board Bolt Remote Controller The data are subject to change without notice. -32-

30 Table 11 Part No No Description KF-70T/B KFR-70T/B KF-70T/B1 KFR-70T/B1 KF-120T/B KFR-120T/B Qty (7031T)A (7041T)A (7031T1) (7051T1) (1231T)C (1251T)B 1 Tube-exit Plate Body Fixing Plate Front Side Plate Left Side Plate \ \ 1 Left Side Plate \ \ \ \ Busing plate Rear Side Plate \ \ 1 Rear Side Plate \ \ \ \ Bottom Foam Motor Gasket Bolt Motor Support Motor FN35D (FN35B) \ \ 1 11 Motor FN50T (FN50T) \ \ \ \ \ 1 Motor FN60T (FN60T) \ \ \ \ \ Centifugal Fan \ \ 1 Centifugal Fan \ \ \ \ Evap Connection Cable-cross Loop Evaporator Assy \ \ \ \ 1 Evaporator Assy \ \ \ \ \ 1 15 Evaporator Assy \ \ \ \ \ 1 Evaporator Assy \ \ \ \ \ 1 Evaporator Assy \ \ \ \ \ Water Tray Screw Electric Plate Flow-guide Loop Electric Box Insulated Clamp B \ \ Terminal Board T360B \ \ \ \ 1 22 Terminal Board GT360B \ \ \ 1 Terminal Board GT5A0B1 \ \ \ \ \ Transformer (SC28B1) Electric Box Cover I I Electric Box Cover II I I PCB \ \ \ \ \ 1 PCB \ \ \ \ \ 1 26 PCB 6051 J 6051 J \ \ \ \ 1 PCB 6053 J 6053 J \ \ \ \ \ PCB 6053BJ 6053BJ \ \ \ \ \ 1 27 Capacitor 3.5uF 3.5uF \ \ 1 Capacitor 4.5uF 4.5uF \ \ \ \ Rubber Plug Drainage Plastic Evaporator Support Nut with Washer M Fixer Water Pump (PJV-1415) Pump Gasket

31 Table 11 continue Part No No Description KF-70T/B KFR-70T/B KF-70T/B1 KFR-70T/B1 KF-120T/B KFR-120T/B Qty (7031T)A (7041T)A (7031T1) (7051T1) (1231T)C (1251T)B 35 Pump Support Water Level Switch Pump Drainpipe Auxiliary Heater \ \ \ \ Right Side Plate \ \ 1 Right Side Plate \ \ \ \ Cable-cross Block Pump Cover Board Bolt Remote Controller The data are subject to change without notice. -34-

32 Table 12 No (1231T)B (1241T)B 22L/A(I) 22R/A(I) 22L/A(I) 22R/A(I) 1 Tube-exit Plate Body Fixing Plate Front Side Plate Left Side Plate \ \ Left Side Plate \ \ \ \ 1 5 Busing Plate Rear Side Plate \ \ Rear Side Plate \ \ \ \ 1 7 Bottom Foam Motor Gasket Bolt M6 M Motor Support Motor FN50T (FN50T) \ \ \ \ 1 11 Motor FN35H (FN35H) \ \ \ \ 1 Motor FN60A (FN60A) \ \ \ \ Centifugal Fan \ \ Centifugal Fan \ \ \ \ 1 13 Evap Connection Cable-cross Loop Evaporator Assy \ \ \ \ 1 Evaporator Assy \ \ Water Tray Screw Electric Plate Flow-guide Loop Electric Box Insulated Clamp B \ \ T360B \ \ \ \ 1 22 Terminal Board T360F \ \ \ 1 T5A0B \ \ \ \ \ Transformer (SC28B1) Electric Box Cover I I Electric Box Cover II I I Description KF-120T/B KF-120T/B -35- Part No GSK24- GSK24- GSK41- GSK41- PCB 6051J 6051J \ \ \ 1 PCB 6053J 6053J \ \ \ Capacitor 3.5uF 3.5uF \ \ \ \ 1 Capacitor 4.5uF 4.5uF \ \ Rubber Plug Drainage Plastic \ \ \ 1 30 Evap Support Nut with Washer M Fixer Water Pump Pump Gasket Pump Support Water Level Switch Pump Drainpipe Auxiliary Heater \ \ \ Right Side Plate \ \ Qty

33 -36- Table 12 continue Part No No Description KF-120T/B KF-120T/B GSK24- GSK24- GSK41- GSK41- Qty (1231T)B (1241T)B 22L/A(I) 22R/A(I) 22L/A(I) 22R/A(I) 39 Right Side Plate \ \ \ \ 1 40 Cable-cross Block Pump Cover Board Bolt Remote Controller (Y512) The data are subject to change without notice.

34 (Blank) -37-

35 7. Explosive view and spare parts list of outdoor unit For 50 model figure

36 -39- Table 13 Part No No Description KF- KFR- KF- KFR- Qty 50W/tA1 50W/tA1 50W/tNA1 50W/tNA1 1 Front Grill Front Plate Front Side Plate Metal Base \ \ 1 Metal Base \ \ Base Support Nut with Washer M8 M Capillary Assy Valve Support Liquid Valve Assy \ \ 1 Liquid Valve Assy \ \ Gas Valve Assy \ \ 1 Gas Valve Assy \ \ Handle Rear Side Plate Compressor 2V34S225AUA 2V34S225AUA \ \ 1 13 Compressor C-2RN170H5U C-2RN170H5U \ \ Rear grill Assy way Valve \ \ way Valve Assy \ \ Silencer \ \ \ \ \ 17 Gas-liquid Separator Isolation Sheet Assy Condenser Assy \ Condenser Assy \ \ \ 1 20 Top Cover Assy Electric Box Capacitor 3uF/450V 3uF/450V Contactor Wire Clamp Velometer TS60 \ \ Terminal Board Capacitor 50uF/440V 50uF/440V \ \ 1 Capacitor 40uF/450V 40uF/450V \ \ Capacitor Clamp Motor Support \ 1 Motor Support \ \ \ Motor FW60D FW60D \ \ 1 Motor FW60B FW60B \ \ Axial Flow Fan The data are subject to change without notice.

37 For 70 model figure

38 Table 14 No 70W/tB1 70W/tB1 70W/tB1N 70W/tB1N 70W/tBN 70W/tBN 1 Front Grill Front Plate Front Side Plate Metal Base Base Support Nut with Washer M8 M Valve Support Description Liquid Valve Assy \ \ \ \ 1 Liquid Valve Assy \ \ Gas Valve Assy \ \ \ \ 1 Gas Valve Assy \ \ Handle Rear Side Plate Capillary Assy \ \ \ Capillary Assy \ \ \ 1 13 Rear grill Assy Compressor AWG5532EVA \ \ \ \ \ 1 Compressor AWG5532EXC \ \ \ \ \ 1 14 Compressor C-RN220H5B \ \ \ \ 1 Compressor C-RN243H8A \ \ \ \ Silencer \ way Valve \ \ \ way Valve Assy \ \ \ Gas-liquid Separator Isolation Sheet Condenser Assy \ \ Condenser Assy \ \ \ \ 1 20 Top Cover Assy Electric Box \ \ \ \ Electric Box \ \ 1 22 Velometer TS Capacitor 3uF/450V 3uF/450V AC Contactor \ \ 1 24 AC Contactor \ \ \ \ Terminal Board Capacitor 45uF/440V(450V) CBB \ \ \ \ 1 Capacitor 40uF CBB65 \ \ \ \ 1 27 Capacitor Clamp \ \ 1 28 Motor Support Motor FW60D FW60D \ \ \ 1 29 Motor FW60T FW60T \ \ \ \ Motor FW60S FW60S \ \ \ \ \ 1 30 Axial Flow Fan KF- KFR- Part No KF- KFR- KF- KFR- Qty The data are subject to change without notice.

39 Table 15 No Description -42- GSK24- Part No GSK24- KF-70W/tB KFR-70W/tB 22L/A(O) 22R/A(O) (7031T)A (7041T)A 1 Front Grill Front Plate Front Side Plate Metal Base Base Support Nut with Washer M8 M Valve Support Liquid Valve Assy Gas Valve Assy Handle Rear Side Plate Capillary Assy Rear grill Assy Compressor AWG5530EXN AWG5530EXN \ \ 1 Compressor AVA5535EXG AVA5535EXG \ \ Silencer way Valve \ \ way Valve Assy \ \ Gas-liquid Separator Isolation Sheet Assy Condenser Assy \ \ 1 19 Condenser Assy \ \ Top Cover Assy Electric Box \ \ Electric Box \ \ 1 22 Velometer TS60 \ \ \ 1 23 Capacitor 3uF/450V AC Contactor \ Terminal Board Capacitor 40uF CBB \ \ 1 27 Capacitor Clamp \ \ 1 28 Motor Support Motor FW60H FW60H \ \ \ 1 Motor FW60C FW60C \ \ \ 1 29 Motor FW60D FW60D \ \ \ 1 Motor FW60T FW60T \ \ \ Axial Flow Fan Qty The data are subject to change without notice.

40 (Blank) -43-

41 For 120 model figure

42 -45- Table 16 Part No No Description KF-120W/tB KFR-120W/tB KF- KFR- Qty (1231T)C (1251T)B 120W/tBN 120W/tBN 1 Front Grill Front Plate Front Side Plate Metal Base \ Metal Base \ \ \ 1 5 Base Support Nut with Washer M8 M Valve Support Liquid Valve Assy \ \ 1 Liquid Valve Assy \ \ Gas Valve Assy \ \ 1 Gas Valve Assy \ \ Handle Rear Side Plate Capillary Assy Compressor AGC5561EXG \ \ \ 1 13 Compressor C-SB373H8A \ \ \ 1 Compressor C-SBN373H8A \ \ Gas-liquid Separator Rear Grill Assy way Valve \ \ way Valve Assy \ \ Silencer Isolation Sheet Assy Condenser Assy \ \ \ 1 19 Condenser Assy \ \ \ 1 Condenser Assy \ \ Top cover Assy Electric Box Capacitor 3.5uF/450VAC Capacitor 50uF/450V Terminal Board T5A0A \ \ Terminal Board T8FOA \ \ \ 1 Terminal Board GT8F0A \ \ \ 1 25 Velometer TS60 \ \ AC Contactor Terminal Board Motor Support Motor FW68T \ \ \ 2 29 Motor FW68D \ \ 2 Motor FW68A \ \ \ Axial Flow Fan The data are subject to change without notice.

43 -46- Table 17 Part No No Description GSK41- GSK41- KF-120W/tB KFR-120W/tB Qty 22L/A(O) 22R/A(O) (1231T)B (1241T)B 1 Front Grill Front Plate Front Side Plate Metal Base \ \ 1 Metal Base \ \ Base Support Nut with Washer M8 M Valve Support Liquid Valve Assy Gas Valve Assy Handle Rear Side Plate Capillary Assy CompressorC-SB373H8A C-SB373H8A \ \ CompressorC-SB303H3B C-SB303H3B \ \ 1 14 Gas-liquid Separator Rear Grill Assy way Valve \ \ way Valve Assy \ \ Silencer \ \ Isolation Sheet Assy Condenser Assy \ Condenser Assy \ \ \ 1 20 Top cover Assy Electric Box Capacitor 3.5uF/450VAC Capacitor 50uF/450V \ \ \ Terminal Board GT8F0B \ \ Terminal Board T5A0A \ \ \ 1 Terminal Board T8F0A \ \ \ 1 25 Velometer TS60 \ \ AC Contactor \ \ AC Contactor \ \ 1 27 Terminal Board Motor Support Motor FW68T FW68T \ \ \ Motor FW68D FW68D \ \ \ 2 Motor FW68E FW68E \ \ \ 2 Motor FW68K FW68K \ \ \ 2 30 Axial Flow Fan The data are subject to change without notice.

44 8. Installation guide Location 1.Do not place object near the air oulet so that conditioned air can reach the whole room. 2.Be sure to install the indoor unit firmly and horizontly. 3.Select the place that can support 4 times of the indoor unit s weight and will not increase noise and vibration. 4.Select a place easy to drain water and connect with the outdoor unit. 5.Make sure there is enough space for maintenance and make sure the distance between the unit and ground is 1.8m or more. 6.Make sure the suspension bolt pitch can hold 4 times of the indoor units s weight,otherwise,you should strengthen the suspension bolt pitch. Note: 1.Keep enough distance from the kitchen. 2.The appliance shall not installed in the lundary Air conditioner 4m or more Exhauster with big enough capacity Heating Ceiling opening and suspension bolt (M10) pitch demension. 950 Decoration panel 890 ceiling opening 840 Indoor unit 780 Suspension bolt pitch Refrigrant piping * Drilling of ceiling must be done by qualified personnel. 780 Suspension bolt pitch 840 Indoor unit 890 ceiling opening 950 panel A Hanger bracket (160) Ceiling View as seen from A 20 or more Note Installation is possible with a ceiling dimension of 890 (marked with * can be 910), but the ceiling-panel overlapping dimension must be 20mm or more. -47-

45 Indoor unit installation 1.Install the indoor unit temporarily. Attach the hanger bracket to the suspension bolt.be sure to fix it securely by using a nut and washer from the upper and lower sides of the hanger bracket.the washer fixing plate will prevent the washer from falling. Refer to the paper pad for installation for ceiling opening demension. The center of the ceiling is indicated on the paper pad for installation,the center of the unit is indicated on the label attached to the unit and on the paper pad for installation. Fix the paper pad to the unit with screws ( 3) 2.Refer to diagram 3, adjust the unit.to the right position for installation. 3.Check if the unit is horizontally level. The indoor unit is equipped with a built-in drainage pump and float switch.at each of the unit s 4 corners,verify that it is level by using a water level or a water filled vinyl tube.(if the unit is tilted against condensate flow,the float switch my malfunction and cause water to drip.) 4.Remove the washer fixing plate used for preventing the washer from falling and tighten the upper nut. 5.Remove the paper pad for installation Field procurement(m10) Washer (attached) Inset Tighten(double nut) (Securing the hanger bracket) Washer fixing plate (Securing the hanger bracket) Fix screw of end of piping at the corner of drainage trough (attached) Center of ceiling opening Pager pad for installation Water level Vinyl tube Fix paper pad for installation Screw (attached) Warning Tighten the nut to prevent the unit from falling. -48-

46 Connection of refrigerant pipe Besure to use both a spanner and torque wrench together as shown in the drawing,connecting or disconnecting pipes to/from the unit. Refer to table 1 to determine the proper tightening torque (over tightening may damage the flare and cause leaks.) When conecting the flare nut,coat the flare both inside and outside with refrigerating machine oil and initially tighten by hand 3 or 4 turns. Check the pipe connector for gas leaks,then insulate it as shown in the drawing below. Use sealing pad (11) to wrap joint between gas pipe and the insulation(8). Coat here with refrigerating machine oil Sealing pad (wrap the joint with the sealing pad) Torque wrench Piping joint Gas piping Liquid piping Insulation for fitting (atteched ) (for liquid pipe) Insulation for fitting (atteched ) (for gas pipe) Flare nut Piping joint Table 1 Pipe gauge Tightening torque Notes N.m 60 65N.m KF(R)-50TW/E1 KF(R)-70TW/B Add 30g Add 30g N.m KF(R)-70TW/B1 Add 30g N.m KF(R)-120TW/B Add 30g The maximun leagth for refrigerant peping is 25 meters,when the length exceeds 10 meters,you should charge additonal (refrigerant as shown in following for per-meter added). -49-

47 Drainage pipe 1.Installation of drainage pipe. The diameter of the drainage pipe should be greater than of equal to the diameter of the connecting pipe[vinyl tube, pipe size:25mm(outer dimension)] Keep the drainage pipe short and sloping downwards at a gradient of at least 1/100 to prevent air pockets from forming. If the drainage hose cannot be sufficiently set on a slope,add a drainage raising pipe. To keep the drainage hose from sagging,keep space between hanging hooks at 1 1.5m mm Right 1/100 Gradient or more Wrong Use the attached drainage hose and clamp.insert the drainage hose into the drainage socket up to the grey tape.tighten the clamp until the screw head is less than 4 mm from the hose. Wrap the big sealing pad around clamp of the drainage hose to insulate. Insulate the drainage hose inside the room. Clamp Clamp Big sealing pad Tape(grey) Drainage hose 4mm Or less Precoutions for drainage raising pipe Install the drainage raising pipe at a height of less than 280 mm. Install the drainage raising pipe at a right angle to the indoor unit and no more than 300 mm from the unit. 300mm or less 1-1.5mm Hanger bracket Drainage raising (attachect) 100mm or more Drainage raising pipe 220mm Ceiling Note The incline of attached drain hose should be 75mm or les, so that the drainage socket does not have to stand additional force. If converging multiple drainage pipes,install according to the procedure shown below. 280mm or less 500mm or less 75mm or less 500mm or less T-joint converging drainage pipes Select converging drainage pipes whose gauge is suitable for the operating capacity of the unit. -50-

48 2.After finishing installation,check if drainage water flows smoothly. Add approximately 600 cc of water to the drainage trough through air outlet or inspection hole slowly and check drainage flow. When electric wiring is finished,check drainage flow during cooling operation. Method of adding water. Service draginage outlet (with rubber stopper) (use this outlet to drain water from the drainge trough) Drainage pipe Service cover Inspection hole 100mm or Adding water through inspection hole Warning:Befone obtaining access to terminals, all supply circuits must be disconnected. Electric wiring All field supplied parts and meterials must conform to local laws and regulations. For electric wiring,refer to WIRING DIAGRAM attached to the unit body. All wiring must be performed by a skilled technician. A circuit breaker capable of shutting down power supply to the entire system and with at least 3 mm contact seperation must be installed. Earth properly. Wiring must conform to national laws and regulations. Installing the protector with not more than 30mA leakage current is a must. If the supply cord is damaged, it must be replaced by the manufactory or its service agents or a similarty qualified person in order to avoid a hazard. Wiring of unit and the controller Wiring of the indoor unit. Remove the control box lid(1),pull the wires inside through rubber bush and wiring according to the WIRING DIAGRAM,then tighten it with clamp. Wiring of the controller. Remove the control box lid(2),pull wires inside through rubber bush and connect to the controller. Wrap the wire with sealing pad(12). After wiring,tighten it with clamp and fix the control box lid(1),(2). Heating and cooling:connect the rubber wire (5-cords) to the power supply terminal board in properly. Cooling:connect the rubber wire (3-cords) to the power supply termiral board properly. -51-

49 three phase one phase L N L1 L2 L3 N L N Come from outside unit Power supply terminal board (3 pcs for C/O,5 pcs for C/H) Clamp(3 pcs for C/H 2 pcs for C/O) Clamp Clamp Rubber bush Control box lid (2) Seal here to avoid leakage Rubber bush Control box lid (1) Precautions:Be sure to connect the indoor unit and outdoor unit at right poles. Installation of panel 1.Set the panel to the indoor unit body by matching the position of the swing flap motor of the decoration panel to the piping position of the panel to the piping position of the indoor unit as shown in fig.4. 2.Install the decoration panel (1) Hang the latch,which is located on the opposite side of the swing flap motor on the panel,temporarily to the book of the indoor unit. (2 Positions) (2) Temporarily hang the remaining 2 latches to the hooks on the sides of the indoor unit.(be careful not to let the swing motor lead wire get caught in the sealing material.) (3) Screw all 4 hexagon head screws located right beneath the latches in approximately 15mm.(panel will rise) (4) Adjust the panel by turning it to the arrowed direction in Fig.4 so that the ceiling opening is completely covered. (5) Tighten the screws until the thickness of the sealing material between the panel and the indoor unit body is reduced to 5 8 mm. -52-

8.Cassette type series

8.Cassette type series 8. 8.1 Summary. figure 8-1 MODEL NOTE KF-50TW/E1(5031T1) KFR-50TW/E1(5051T1) KF-70TW/B1(7031T1) KFR-70TW/B1(7051T1) KF-50TW/E1(5031T1)N KFR-50TW/E1(5051T1)N KF-70TW/B1(7031T1)N KFR-70TW/B1(7051T1)N KF-70TW/B(7031T)C

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 Model: AC-S10CG 3 Content Technical specification..

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR C18 GE AIR C24 GE AIR C34 GE AIR C41 1 Introduction and Features Model Remarks

More information

1. CF0.5E CF0.5M CF0.8E CF0.8M type

1. CF0.5E CF0.5M CF0.8E CF0.8M type 1. CF0.5E CF0.5M CF0.8E CF0.8M type 1.1 Summary CF0.5M CF0.8M CF0.5E CF0.8E Fig. 1-1 Fig. 1-2 MODEL NOTE CF0.5M CF0.5E CF0.8M CF0.8E CE 1Ph 220-230V 50Hz R134a -1- 1.2 Technical specifications Table 1-1

More information

CASSETTE TYP FANCOIL UNIT SERVICE MANUAL

CASSETTE TYP FANCOIL UNIT SERVICE MANUAL CASSETTE TYP FANCOIL UNIT SERVICE MANUAL (GC201109-I) Contents PRODUCT...2 1. MODELS LIST...2 2. NOMENCLATURE OF THE UNIT...3 3. FUNCTION...3 4. PRODUCT DATA...4 CONTROL...10 1. WIRELESS REMOTE CONTROLLER...10

More information

Service Manual & Installation Manual

Service Manual & Installation Manual GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR

More information

Air Conditioner Service Manual

Air Conditioner Service Manual Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 MODEL: AC-S7HGB 3 CONTENTS TECHNICAL SPECIFICATION..4

More information

Air Conditioner Service Manual

Air Conditioner Service Manual Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 MODEL: AC-S13CEGL1 3 CONTENTS TECHNICAL SPECIFICATION...

More information

2. Mobile Air-conditioner (KY-32)

2. Mobile Air-conditioner (KY-32) 2.1 Summary 2. Mobile Air-conditioner (KY-32) figure 2-1 MODEL NOTE KY-32/K101 KYD-32/K101 CE STANDARD 1Ph 220-230V 50Hz R407C GP12-22L 1Ph-220V 60Hz R22 GP12-12L GP12-12R 1Ph-115V 60Hz R22 KY-32U/11156

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

Condensing Unit Service Manual (T1/R410a/60Hz)

Condensing Unit Service Manual (T1/R410a/60Hz) GREE COMMERCIAL AIR CONDITION DUCT TYPE SPLIT AIR CONDITIONER Condensing Unit Service Manual (T/R40a/60Hz) GREE ELECTRIC APPLIANCES INC. OF ZHUHAI CONTENTS PRODUCT... 2 MODELS LIST... 2 2 NOMENCLATURE...

More information

6868 Ardmore Street Houston, Texas Toll Free Phone Fax

6868 Ardmore Street Houston, Texas Toll Free Phone Fax P-09 P-09 P-09A COMPONENT PART NO. COMPONENT PART NO. BASE PAN 67904000 AIR OUTTAKE 67809008 OUTDOOR CENTRIFUGAL FAN 67809032 TURNING WHEEL (CASTER) 67904001 (4) ERECT LOUVER ASSY 67809006 (5) OUTDOOR

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

Service Manual. Air Conditional

Service Manual. Air Conditional Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30CM -3 - CONTENTS SPECIFICATION...

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION FLOOR /CEILING INDOOR UNIT MODEL: SMUL 12,18,24,30,36,48,60 Read this instructions carefully before installation. P. 12 P. 01 Dimemsion RHEEM REV 01 P. 02 P. 11 Detaching the mounting

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB Service Manual Models WAH48115MB WAH412230MB WH48YMB WH412ZMB TABLE OF CONTENT SPECIFICATION... 2 OUTLINE AND INSTALLATION DIMENSION... 4 REFRIGERATION SYSTEM DIAGRAM... 5 WIRING SCHEMATIC... 6 CONTROLS

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB Service Manual Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB TABLE OF CONTENT TABLE OF CONTENT... 1 SPECIFICATION... 1 OUTLINE AND INSTALLATION DIMENSION... 3 REFRIGERATION SYSTEM DIAGRAM... 6 WIRING

More information

INSTALLATION MANUAL. Decoration Panel BYCP125K-W1 MODELS

INSTALLATION MANUAL. Decoration Panel BYCP125K-W1 MODELS INSTALLATION MANUAL Decoration Panel English MODELS BYCP125K-W1 READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. BYCP125K-W1 Decoration Panel

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 Contents Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 The specifications, designs, and information in this book are subject to change without notice for product improvement.

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU INSTALLATION MANUAL Four-Way Cassette Model B-VMH09CU- B-VMHCU- B-VMH8CU- 57.787.00 www.marsdelivers.com If used as MULTI unit, please refer to the Installation & operation manuals packed with outdoor

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................

More information

Service Manual. Air Conditional

Service Manual. Air Conditional Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30HM -3 - CONTENTS SPECIFICATION...

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

Thank you for selecting LENNOX air conditioners.

Thank you for selecting LENNOX air conditioners. S Models: LI012CI-180P432 LI012CO-180P432 LI012HI-180P432 LI012HO-180P432 LI024CI-180P432 LI024CO-180P432 LI024HI-180P432 LI024HO-180P432 (Refrigerant R410A) Thank you for selecting LENNOX air conditioners.

More information

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL INSTALLATION INSTRUCTIONS CEILING CASSETTE TYPE INDOOR UNIT Read this installation instructions carefully before installing

More information

Multi-Split Cassette Type Indoor Unit

Multi-Split Cassette Type Indoor Unit Installation and Operation Manual Multi-Split Cassette Type Indoor Unit For models: ACMI-26HPDC1 ACMI-36HPDC1 ACMI-53HPDC1 Please read this manual carefully before the installation and operation of this

More information

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5 This is the list of service parts for the MDT2C12A-1A and MDT2C12A-1B ice maker dispensers. The B series model began in late 2014. It has a number of electrical differences from the prior model. Always

More information

4. Disassembly and Reassembly

4. Disassembly and Reassembly 4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner

More information

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH Outdoor Units - appearance 18,000Btu/h 30,000~36,000Btu/h 24,000Btu/h 48,000Btu/h-60,000Btu/h Model Names of Outdoor Units

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only ED 40-437 Packaged Air Conditioners Duct Connection Type [50Hz] (Middle Static Pressure Application) FDMG-AV1(S) Series Cooling Only ED40-437 Duct Connection Type Middle Static Pressure Application [50Hz]

More information

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI MULTI DUCTLESS INVERTER HEAT PUMP PANEL CONSOLE TYPE INDOOR UNIT INSTALLATION MANUAL Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI Thank you for choosing a C&H Multi Ductless Heat Pump! You can feel confident

More information

Floor-Standing Type(E Series)

Floor-Standing Type(E Series) Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch

More information

AIR CONDITIONER CASSETTE

AIR CONDITIONER CASSETTE Installation manual AIR CONDITIONER CASSETTE English 10. REFRIGERANT TUBING...17 11. PANEL INSTALLING...19 12. FINAL TASKS...21 1 1. REQUIRED TOOLS FOR INSTALLATION WORK 2. SAFETY PRECAUTIONS Installation

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

Air Conditioner. user installation & manual manual. imagine the possibilities

Air Conditioner. user installation & manual manual. imagine the possibilities ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers Please read this manual carefully before installation and keep it for future reference. Installation Manual Olympus Series Cassette Air Handlers The design and specifications are subject to change without

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................

More information

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1 INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ0D7GW BYCQ0D7GFW BYCQ0D7GW BYCQ0D7GFW Installation manual Contents. SAFETY PRECAUTIONS....

More information

AIR CONDITIONER CASSETTE

AIR CONDITIONER CASSETTE Installation manual AIR CONDITIONER CASSETTE English Part Number: 453195200/03 10. REFRIGERANT TUBING...17 11. PANEL INSTALLING...19 12. SPECIAL SETTINGS...22 13. SELF DIAGNOSTICS...23 14. FINAL TASKS...26

More information

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax: Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE

More information

Mini-Split Air Conditioner

Mini-Split Air Conditioner Cassette Type Installation Manual New Released A-Cassette-600 Mini-Split Air Conditioner DC Inverter Cassette Type Unit All Model Numbers Table of Contents Installation Manual 2 3 Accessories... 04 Safety

More information

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow)

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) EDUS 39-600 - F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) AMERICAS EDUS39-600-F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) 1. External Appearance...2 2. Specifications...3 3. Dimensions...5

More information

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9. Specifications (Model) KSIB009-H116 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*)

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

DC Inverter Multi-split System Technical Manual - 50Hz/R410a DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/2.0 General Information Contents Part 1. General Information... 4 1. Features... 4 2. Nomenclature... 6 3. Products Line-up...

More information

Service Parts for models UF424 and UN324

Service Parts for models UF424 and UN324 Service Parts for models UF and UN This is the illustrated parts list for Scotsman ice maker models UF and UF. They were manufactured as either air or water cooled models, plus the air cooled models were

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT

More information

R410A50Hz Universal Outdoor Series Technical Manual

R410A50Hz Universal Outdoor Series Technical Manual Outdoor Unit R410A 50Hz Universal Outdoor Series Technical Manual 2013 Version LCAC/2.0/201308 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature...

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement. MCAC-ATSM-2014-01 Content R410A Mini Split Chiller 50Hz 1. Model Names of Outdoor Units... 2 2. External Appearance... 2 3. menclature... 3 4. Features... 4 5. Descriptions of Standard Unit... 6 6. Specifications...

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

SERVICE PARTS MANUAL PEARL ICE / WATER DISPENSER MODEL- GEMD270A

SERVICE PARTS MANUAL PEARL ICE / WATER DISPENSER MODEL- GEMD270A SERVICE PARTS MANUAL PEARL ICE / WATER DISPENSER MODEL- GEMD270A 14-1034 Date 5/26/16 11100 E. 45th Avenue Denver, CO 80239 WWW.iceomatic.com MODEL-ICE0320, ICE0520 22 INCH WIDE ICE SERIES CUBERS SERVICE

More information

PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER

PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER INDOOR CEILING MOUNT PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER #70006 #70007 #70008 #70009 INSTALLATION MANUAL This manual only describes the installation of the indoor

More information

AIR CONDITIONER CASSETTE

AIR CONDITIONER CASSETTE Installation manual ENGLISH AIR CONDITIONER CASSETTE English Indoor unit cassette type 10. REFRIGERANT TUBING...19 14 16 11. PANEL INSTALLING...21 12. FINAL TASKS...23 1 1. REQUIRED TOOLS FOR INSTALLATION

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS. SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

Installation Manual Super-Slim Four-Way Cassette

Installation Manual Super-Slim Four-Way Cassette Installation Manual Super-Slim Four-Way Cassette Models: MCOVT S / MROVT AS IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

Nortek Global HVAC, LLC

Nortek Global HVAC, LLC Nortek Global HVAC, LLC DC Inverter U-match Series Cassette Type Unit Owner's Manual Heat Pump Indoor Unit GKU18(5.3)USV2FL GKU24(7.0)USV2FL GKU30(8.8)USV2FL GKU36(10.6)USV2FL GKU42(12.3)USG2FL GKU48(14.1)USG2FL

More information

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents. All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June

More information

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL (Inverter Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

Notices for installation

Notices for installation Notices for installation Important Notices Before installing, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may

More information

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 QUICK CONNECT DUCTLESS MINI-SPLIT SYSTEM INSTALLATION MANUAL FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 Before using your air conditioner, please read this manual carefully and keep it for

More information

CK C O M P R E S S O R

CK C O M P R E S S O R CJ62 6232 32CK CK C O M P R E S S O R TECHNICAL SPECIFICATION ; HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2011.8 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

Installation & Maintenance Manual

Installation & Maintenance Manual Installation & Maintenance Manual INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CDITIERS - SET-FREE SERIES - Type In-the-Ceiling (Duct) Model RPI-3.0FSN2SQ RPI-4.0FSN2SQ RPI-5.0FSN2SQ RPI-6.0FSN2SQ

More information

KTIM. Four-way Cassette Type

KTIM. Four-way Cassette Type KTIM INSTALLATION MANUAL Four-way Cassette Type Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Inverter Split System Air Conditioner COOL/ DRY Model This air conditioner uses the new refrigerant R40A. Refrigerant service valve size = 5/6" Contents Page Model Combinations

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER CEILING & FLOOR TYPE AIR CONDITIONER Installation Manual Ceiling & Floor Type IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units Installation and Operation Manual CMA12SB-0 Series Horizontal/Side Discharge Condensing Units 517.787.2100 www.marsdelivers.com www.heatcontroller.com Heat Controller CONTENTS PAGE 1. PRES... 1 2. INSTALLATION

More information

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type. AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: 1-Way Cassette Type MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E English SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type 1 Original instruction

More information

42PHW / 42PHQ 42PHQ...K

42PHW / 42PHQ 42PHQ...K 42PHW / 42PHQ 42PHQ...K INSTALLATION MANUAL Split system Hi-Wall indoor unit For operation and maintenance instructions of this unit, as well as installation instructions of the outdoor unit, refer to

More information

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Please read this user manual first! Dear Customer, Thank you for preferring a Beko product.

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information