VEKA ver C Supply air unit

Size: px
Start display at page:

Download "VEKA ver C Supply air unit"

Transcription

1 Air omfort Air Treatment VEKA ver VEKA ver Supply air unit» Integrated ontrol Equipment uro

2 2 Supply air unit VEKA Integrated ontrol Equipment uro Innehåll 1.. Electrical connections Page 1.1 Motors Electrical Post heater Main supply onnection of control panel onnection of external components 2.1 Electrical Post heater Post heater, hot water ooling coil, water ooling coil, DX Damper Temperature sensors Extended/Forced Ventilation Fire protection function Summary alarm External exhaust fan Filter guard Wiring diagram ontrol panel, operations, commissioning Page 4.1 General Home screen Sub menus Date and time, language Advanced Settings for installers and service personnel ommissioning Wizard Schedules ontrol functions 5.1 Heating and ooling Temperature controls Freeze protection Fan control ommunication 6.1 Modbus, RS Modbus, TP/IP Webserver Parameter list DeclaraTION OF conformity...30

3 Integrated ontrol Equipment uro Supply air unit VEKA 3 1. Electrical connections 1 NY BILD! ontrol board 2. Transformer 230/24 V 3. Terminals 4. Fuse, 24 V, 4 A 1.1 Motors Size Power, kw urrent, A Voltage, V 20 0,77 kw (0,385 kw x 2) 5 A (2,5 A x 2) 1 x 230 V 30 1,50 kw (0,75 kw x 2) 6,6 A (3,3 A x 2) 1 x 230 V 1.2 Electrical post heater Size Power, kw urrent, A Voltage, V x 400 V x 400 V x 400 V x 400 V 1.3 Main supply The main supply cable must be fitted with an external safety switch located close to the unit. Ambient temperature Main supply 1 x 230 V. Fuse 10 A.

4 4 Supply air unit VEKA Integrated ontrol Equipment uro 1. ELETRIAL ONNETIONS 1.4 ONNETION OF ONTROL PANEL The control panel is connected when delivered from factory and provided with a magnet for easy handling. For wall mounting see below. 5. onnect the cable to the back of the display as shown above. Note. Please do not touch the electronics. 6. Push back the display in the enclosure. 1. Open the control panel using a screwdriver. NOTE! The control panel is only for indoor use. 2. Lift the display out of the enclosure. 3. Push the connection cable through a suitable hole and if needed make an outlet for the cable in the side of the cover. 4. Mount the enclosure directly on the wall.

5 Integrated ontrol Equipment uro Supply air unit VEKA 5 2. onnection of external components Use the control box on the outside of the unit to connect all external accessories. For information about how to connect available accessories see below. 2.1 Electrical post heater Duct mounted. Separate supply 3 x 400V. onnect alarm, start and control signal to the control box. The unit is preconfigured for electrical post heater. omponent Designation onnection Remark P1/SK1 1-2 Start signal Heating - NO Electrical ALM P ) Alarm, overheating (N) heater SV1 TRL ontrol signal 0-10 V Y - M Supply 3 x 400 V Not from the unit 1) onnects directly to the control board. 2.2 Post heater, hot water irculation pump (P1) and valve actuator (SV1) connects according to table below. omponent Designation onnection Remark P1/SK1 Pump supply 1 - N - PE Heating (230 V max 2A 2) ) irculation pump P1 P1/SK1 Heating 2-3 NO - L1 Loop only with circulation pump ALM P ) Voltfree alarm input (NO, configurable) Valve actuator SV1 SV1 TRL Y - M - G - GO 1) onnects directly to the control board. 2) The current consumption for P1 and P2 is limited to 2 A. A separate safety switch for the pump is needed if it is a long distance between the pump and the AHU. 2.3 ooling coil, water irculation pump (P2) and valve actuator (SV2) connects according to table below. omponent Designation onnection Remark P2/DX Pump supply 4 - N - PE ooling (230 V max 2A 2) ) irculation pump P2 P2/DX ooling 5-6 NO - L1 Loop only with circulation pump ALM P2/DX Voltfree alarm input (NO, configurable) Valve actuator SV2 SV2 TRL Y - M - G - GO 1) onnects directly to the control board. 2) The current consumption for P1 and P2 is limited to 2 A. A separate safety switch for the pump is needed if it is a long distance between the pump and the AHU. 2.4 ooling coil, DX The unit can manage cooling DX, 1-step. Note that the coil is not included in the delivery of the unit. For configuration see control functions. omponent Designation onnection Remark DX-cooling, P2/DX ooling NO Start: 10 % Stop: 0 % 1-step ALM P2/DX ) Voltfree alarm input (NO, configurable) 1) onnects directly to the control board. 2.5 Spjäll On/off actuator with spring return, 15 Nm, 24 VA. omponent Designation onnection Remark Damper ST G - GO Exhaust air damper if used is connected in parallel (Maximum 2 dampers) 2.6 Temperature sensors The unit is provided with: Supply air sensor GT1, delivered separately. Duct mounting. able not included. Room temperature sensor GT2 (accessory) is supplied when the unit is configured for room temperature control. The room sensor is intended for wall mounting and needs to have good air circulation and not direct sun light. able not included. Outdoor air sensor GT3 (accessory) is supplied when the unit is configured for outdoor air compensation. Duct mounting. able not included. Frost protection sensor GT5 is supplied when hot water coil is used. Immersion sensor. omponent Designation onnection Remark Supply air sensor GT ) Duct mounting Room temperature GT2 sensor ) Wall mounting Outdoor air sensor GT ) Duct mounting Frost protection sensor 1) onnects directly to the control board. GT ) Immersion sensor

6 6 Supply air unit VEKA Integrated ontrol Equipment uro 2. onnection of external components 2.7 Extended / forced ventilation For external electronic timer, push button, PIR or other volt free contact. Electronic timer and/or PIR if ordered is supplied separately. When using a push button the time has to be set in the control panel. 2.8 FIRE PROTETION FUNTION External fire alarm to stop the unit can be connected to terminals in the control box. Smoke detectors and fire dampers cannot be connected directly to the air handling unit, a separate fire system is needed. omponent Designation onnection Remark Timer 1 TMR ) Timer 2 TMR ) 1) onnects directly to the control board. omponent Designation onnection Remark Fire protection funcion FIRE ) Voltfree contact (N) Looped at delivery 1) onnects directly to the control board. Function of aux. inputs Timer 1 (T1) and Timer 2 (T2) can be selected according to the following tables. Timer Function 1 (default) Timer 1 Timer 2 Manual/Automatic Mode 0 0 Trickle 1 0 Normal 0 1 Boost 1 1 Timer Function 2 Timer 1 Timer 2 Manual/Automatic Mode 0 0 Trickle 1 0 Boost 0 1 Stop 1 1 Timer Function 3 Timer 1 Timer 2 Manual/Automatic Mode 0 0 Normal 1 0 Boost 0 1 Stop 1 1 Timer Function 4 Timer 1 Timer 2 Stop 0 0 Manual/Automatic Mode 1 0 Stop 0 1 Boost 1 1 Timer Function 5 Timer 1 Timer 2 Stop 0 0 Manual/Automatic Mode 1 0 Stop 0 1 Normal Summary alarm The alarm output can be configured to indicate A-alarms or both A- and B-alarms. omponent Summary alarm Designation onnection Remark ALM ) Voltfree contact Maximum load 24 V, 200 ma 1) onnects directly to the control board External exhaust fan External exhaust fan (FF) with frequency converter connects according to the following table. omponent Designation onnection Remark External ontrol signal 1) Y - M exhaust fan Alarm ) Voltfree contact, (NO, configurable) 1) onnects directly to the control board Filter guard Filter guard (GP1) connects according to the following table. omponent Designation onnection Remark Filter guard GP ) Voltfree contact (NO) 1) onnects directly to the control board.

7 G 24 V G0 G 24 V G0 Integrated ontrol Equipment uro Supply air unit VEKA 7 3. Wiring diagram T1 230 V 24 V ontrol Board DO9 ontrol Board DO10 Supply ontrol Board 230 V 24 V Sid 2 TF Brown Blue Yellow/Green TF Brown Blue Yellow/Green P1/SK1 Start SK1 Blue Brown P2/DX Start 2) Loop only with circulation pump DX Supply fan (2 parallel) Alt. 1 Start Electrical Heater Alt. 1 Start DX ooling Outside unit Not in Fläkt Woods delivery Q External Safety Switch (Accessory) Alt. 2 irculation pump Heating (max 2 A totaly) Alt. 2 irculation pump ooling Main supply 1 x 230 V, 50 Hz Fuse Protection 10A (Electrical heater has separate supply) ontrol Board Digital Outputs (D0) Summary Alarm (Max 24 V, 0,2 A) 12 DO DO8 Reläkort G G0 30 Shut-off damper ST1 Analogue Outputs (A0) ontrol Signal Supply Fan TF 66 Y Ref A01 67 M Modbus RS485 A B RS ontrol Signal External Fan TF Y A02 65 M Alt. 2 ontrol Signal Electrical Heater Alt. 1 Actuator Heating Ethernet TP/IP Ethernetcard 62 A Y M 21 Y G M G0 24 ontrol Panel uro Touch 58 A05 59 SV2 Actuator ooling 25 Y G M G0 28

8 8 Supply air unit VEKA Integrated ontrol Equipment uro 3. Wiring diagram ontrol Board Digital Inputs (DI) External Timer 1 TMR1 NO DI1 DI NO Alt. 1 Alarm P1 Heating N Alt. 2 Alarm Electrical Heat. NO NO External Timer 2 TMR2 DI2 16 DI10 40 Alarm irculation pump P2/DX cooling Supply Filter Alarm GP1 NO DI3 DI NO Alarm External Exhaust Fan FF N N Fire Alarm DI8 DI5 Alarm Supply Fan TF (Fan 1) N Alarm Supply TF (Fan 2) Analogue Inputs (AI) B Vit Vit B Supply Air Temp. GT1 M Brun AI1 47 AI4 53 Brun M GT5 Freeze Protection Sensor Outdoor Air Temp. GT3 B M Vit Brun 48 AI2 49 B Vit 50 Room Temp. GT2 M Brun AI V Terminals 2 3 N 2 3 N 5 6 N External connections diagram 230 V 25 L1 N 5 6 N ) 2) Safety Switch (iaccessory) Main Supply 1 x 230 V, 50 Hz Fuse Protection 10 A (Electrical Heater has separate supply) Alt. 1 Supply P1, 230 V Alt. 2 MStart electrical heater. Volt free contact P1/SK1 START 1) Loop only with P1, Alt. 1 Max 2A in total Alt. 1 Supply P2, 230 V Alt. 2 Start DX-cooling. Volt free contact P2/DX START 2) Loop only with P2, Alt. 1 Y M SV1 TRL, Valve actuator Heating G GO Y M SV2 TRL, Valve actuator ooling G GO G GO ST1, Shut-off damper

9 Integrated ontrol Equipment uro Supply air unit VEKA 9 3. Wiring diagram External connections diagram 24 V onnects directly to the control board NO NO NO NO NO ALM, Summary Alarm (Max. 24V, 0.2 A) TMR1, Ext. Timer input 1 TMR2, Ext. Timer input 2 GP1, Supply Filter Alarm FF Ext. LExhaust Fan Alarm P1, Alarm Input Heating FIRE, Fire Alarm Inout (Looped at delivery) GT1, Supply temp. Sensor NO P2, Alarm Input ooling N NO B M B M B M B M Y M Ref A B Timer function 1 (Default) TMR 1 TMR 2 Low speed 1 0 Normal speed High speed For other time functions, see manual. When using electrical heater, the sensor has to be fitted after the heater GT3, Outdoor air temp. sensor GT2, Room temp. sensor GT5, FFreeze Protection sensor FF, External Exhaust Fan, ontrol signal MODB, Modbus RS485

10 10 Supply air unit VEKA Integrated ontrol Equipment uro 4 ontrol panel, operations, commissioning 4.1 General HMI This section provides an introduction to the touchscreen LD control panel, also known as the Human Machine Interface, or simply, HMI. The HMI serves two main purposes: To provide information about the current operational state of the unit. To allow the unit to be setup and configured. Touch Screen Tips To select an item, touch the center of the icon or option. Do not press too hard, the touch screen is sensitive enough to pick up light, firm touches. Use the tip of your finger or the back of a pencil to touch the required option. Be careful not to touch any other options. leaning the Screen Disconnect the power cord. Gently wipe the screen with a soft, dry non-abrasive cloth. If the marks remain, moisten the cloth slightly with a detergent that is de signed for LD or mobile screens and wipe the screen gently from top to bottom. Never use other detergents, as these may contain ammonia or other additives. IMPORTANT: Never spray, or pour liquids directly on to the screen. Do not clean the screen while the system is on. onventions used within this manual The following buttons and symbols are universal and available on many menu pages. Home key, to return to the Home Screen. Back button, to cancel and return to the previous page. onfirm button to confirm and proceed. hanging a value: Option 1: Press the arrow keys to increase or decrease the value. Option 2: Press the displayed number to numerically adjust the value. Using the Unit Powering On Use the number buttons to enter a value. onfirm with or cancel with. Values that can only be read, but not written, are displayed without a surrounding window. Values that can be both read and written, are displayed with a surrounding window. Some submenus has several pages. Touch the upper or the lower part of the scroll list to navigate between pages. Each time power is applied, the unit will run through a series of internal system tests which take approximately 20 seconds to complete. Once the internal system tests have been completed, the HMI will always display the Home screen. The unit will be in Manual Mode the first time that power is applied. Home Screen From the Home screen it is possible to determine how the unit is operating as well as navigating to further screens to configure the unit to suit the demands of the end system. From the Home Screen, it is possible to: Navigate to further configuration screens to setup system parameters. Manually adjust the fan speed. Determine the operating status of the product. Interrogate and acknowledge system alarms.

11 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning 4.2 Home screen Status line Post-heater active ooling active urrent set point value lock 18 11:08 Alarm No alarm Alarm B Alarm A Operating status Manual mode Automatic mode Timer 1 Timer 2 Timer 1/Timer 2 Stop Operating modes Shut down time Trickle or low speed Normal or medium speed Boost or high speed

12 12 Supply air unit VEKA Integrated ontrol Equipment uro 4. ontrol panel, operations, commissioning 4.2 Home screen, cont. Shortcut to set the temperature set point Shortcut to ommissioning Wizard Shortcut to set the time and date Alarm See section Select operating mode See section 4.3. Stop ManuAl Automatic User Settings See section 4.3. Trickle or low speed Normal or medium speed Boost or high speed Press each field to select the operating mode. Only active in Manual Mode.

13 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning 4.3 Sub menus Operating Modes The operating status icon present on the Home Screen displays the current operating mode. To change the operating mode, press the large fan icon located on the Home Screen. The unit has three operating modes selectable through the Operating Modes screen: Stop Mode: In this mode, the unit will stop both the supply and the extract fans. Manual Mode: In this mode, the unit can be manually adjusted on the Home Screen to run at three different speeds. Automatic Mode: In this mode, the unit will be automati cally controlled using internal sche dules and timers, O 2 demand control, PIR sensors, etc. Alarm Screen The alarm icon on the Home Screen indicates the status of any system alarms: No alarm Alarm B Alarm type B are deemed non-critical and do not stop the unit ventilation. Alarm type A are deemed critical and will Alarm A cause the unit to stop ventilating. Press the icon to enter the Alarm Screen. User Settings Temperature status The temperature set point is used to determine when the post-heater (if fitted) starts to warm the supply air entering the property. The temperature set point can be adjusted to any temperature between 15 and 35, factory setting is 19. Temperatures and output signals are read only values. Fan Status From the Fan Status screen it will be possible to view parameters such as supply and exhaust fan speeds, %. Air Quality Not for VEKA. System Overview Version ontrol Panel IP Octet 1 Bootloader ontrol Panel IP Octet 2 Version ontrol ard IP Octet 3 Bootloader ontrol ard IP Octet 4 Unit type VEKA Schedules Example 1: No alarm Example 2: Active alarms learing Alarms To clear an individual alarm, press the Ack button. To clear all the Alarms press the Ack All button on top of the screen. It may not always be possible to clear the status of an alarm as the source of the alarm may immediately trigger the status to return. For example, it will not be possible to clear a faulty temperature sensor alarm until the sensor itself has been repaired or replaced. Read only. For more information see section Schedules, section 4.7. Advanced settings See section Advanced settings, section 4.4. Alarm history

14 14 Supply air unit VEKA Integrated ontrol Equipment uro 4. ontrol panel, operations, commissioning 4.4 Date and time, language Settings To enter the settings menu: Date/time 1. Set the date and press the onfirm button. 1. Push the gear cog button. 2 Set the time and press the onfirm button 2. Push the spanner button. hoose Language 3. In this menu you set the date, time and language. It is also possible for installers and service personnel to log in and access additional parameters. 1. hoose the appropriate language flag and press the onfirm button. Note, further language flags are available after pressing the right arrow icon. Not all translations are available.

15 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning 4.5 Advanced Settings for installers and service personnel Settings for installers and service personnel This section provides an overview to the more advanced operations that are available from the Home Screen via the passcode protected Advanced Settings option. Numerous system parameters can be adjusted through the Settings Screen; however, only those that are relevant and appropriate to the scope of the HMI User Manual will be described. It is strongly recommended to avoid the adjustment of any system parameters not outline within this section. Access to the Settings Screen is passcode protected to prevent system critical parameters from being accidentally adjusted to values that could compromise the correct operation of the unit. Therefore, extreme caution should be observed when adjusting Advanced Settings parameters. Login Advanced settings requires the Login passcode, 0000, to be entered. 1. Enter the correct passcode and press the onfirm button.

16 16 Supply air unit VEKA Integrated ontrol Equipment uro 4. ontrol panel, operations, commissioning 4.6 OMMISSIONING WIZARD There are two ways to start the wizard. 1. Press the question mark on the start screen. The question mark is not shown if the wizard has been started earlier. 2. hoose 2. Run ommissioning Wizard under Settings/Login Press 2.1 Start to get a step by step guidance through the settings needed during commissioning, or go directly to a specific menu to change a single value.

17 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning Menu 2.2 refers to external exhaust fan if any. Option 2 - Use the numerical keypad, confirm with. option 1 option 2 There are two ways to change the fan speeds: Option 1 Press Trickle, Normal, Boost, the use ±1 or ±10 buttons Option 2 Press the values within the boxes adyescent to Trickle, Normal or Boost, then use the numerical keypad. When completed, press the confirm button to proceed to next step. Option 1 - Use ± buttons Make the appropriate settings for the supply fan.

18 18 Supply air unit VEKA Integrated ontrol Equipment uro 4. ontrol panel, operations, commissioning Enter desired temperature setpoint value. If using outdoor temperature compensation or room control also set the minimum and maximum temperature for the supply air. To end the commissioning wizard press the red cross button. Press the to continue to schedules. See section 9.7

19 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning 4.7 Schedules The controller has three types of internal time schedules: Weekly, Single date and Date period. First, program the weekly schedule with the required times. Then use any single date programs and the period to enter exceptions. Each schedule also needs to be activated. This is done by pressing the grey tick button. A green tick indicates that the schedule is active. Priority When several enabled applications overlap, the following applies: Lowest priority Weekly 1 Weekly 8 Single date 1 Single date 4 Date period 1 Highest priority Date period 4 Weekly-schedule (1-8) By using a weekly schedule the unit can be programmed to operate at trickle, normal and boost speed alternatively stop. Example 1 Below is an example of a weekly schedule configured to run the fans at normal speed from to Monday to Friday. At all other times, the fans are turned off. Day Time Fan speed Monday 8 18 Normal Tuesday 8 18 Normal Wednesday 8 18 Normal Thursday 8 18 Normal Friday 8 18 Normal Other time Stop Only Weekly 1 should be activated.

20 20 Supply air unit VEKA Integrated ontrol Equipment uro 4. ontrol panel, operations, commissioning 4.7 Schedules, cont. Example 2 Below is an example of a weekly schedule configured to run the fans at normal speed from to Monday to Thursday, from to on Friday and to on Saturday. At all other times, the fans are turned off. Example 3 Below is an example of a weekly schedule configured to run the fans at normal speed from to Monday to Friday. At all other times, the fans are configured to run at trickle speed. At trickle speed the temperature set point will be decreased by two degrees. Day Time Fan speed Monday Normal Tuesday 8 18 Normal Wednesday 8 18 Normal Thursday 8-18 Normal Friday 8-17 Normal Saturday Normal Other time Stop Day Time Fan speed Temperature set point Monday 8 18 Normal 0 Tuesday 8 18 Normal 0 Wednesday 8 18 Normal 0 Thursday 8 18 Normal 0 Friday 8 18 Normal 0 Other time Trickle (Low) 2 1 Weekly 1 Fan speed Normal Temp set point Rel 0 1 Weekly 1 Fan speed Trickle Temp Setpoint Rel -2 From Mon To Fri Daily 08:00 18:00 From Mon To Sun Daily 00:00 23:59 2 Weekly 2 Fan speed Stop Tem Setpoint Rel 0 2 Weekly 2 Fan speed Normal Temp Setpoint Rel 0 From Fri To Fri Daily 17:00 18:00 From Mon To Fri Daily 08:00 18:00 3 Weekly 3 Only Weekly 1 2 should be activated. Fan speed Normal Temp Setpoint Rel 0 From Sat To Sat Daily 10:00 14:00 Only Weekly 1 3 should be activated.

21 Integrated ontrol Equipment uro Supply air unit VEKA ontrol panel, operations, commissioning 4.7 Schedules, cont. Single date schedule (1-4) A single date schedule is defined as a one-off schedule that automati cally starts and finishes on the same date. Note!! Remember to enable the desired time channels by pressing Example The unit must be switched off on 6 June. Date period schedule (1-4) A date period schedule is defined as a one-off schedule that is configured to run between any two dates. Example The unit must be switched off between 24 December and 26 December.

22 22 Supply air unit VEKA Integrated ontrol Equipment uro 5. ONTROL FUNTIONS 5.1 HEATING AND OOLING The unit is configured differently regarding to heating and cooling, see below. HEATING No heater Electrical post heater Hot water coil OOLING No cooling Water DX, On/Off ontrol function The control function works as follows: Regardless of control mode the unit tries to achieve the desired setpoint. This is done by the unit depending on the needs, demand for heat recovery, heating or cooling. Built into the system is also a dead zone. The dead zone function (usually 2 ) acts as a temperature zone between heat recovery and cooling where neither calls for heat recovery or cooling. ontrol signal, % Heating Sequence control Figure 1. The figure shows the controller s output signals to the various components at different temperatures. The zone between T1 and T2 is called the dead zone. ooling T0 T1 T2 T3 Temperature, 5.2 Temperature controls VEKA has two temperature control options, supply air, and room control. In addition it is possible to use outdoor temperature compensation. This control mode cannot be combined with room control. To obtain other control modes, first the controller must be changed from standard mode to cascade mode. Then control mode is selected by changing the cascade reference to room control (0) or outdoor temperature compensation (1). Below is a description of the different control modes. Supply air control To maintain a constant supply air temperature, the controller works with the setpoint and the supply air temperature. Based on these parameters, the current heating and cooling sequences are controlled. Room control Room control gives the best control of temperature in a specific room and is used when only one unit serves this room. This method works best for larger premises. This enables the unit to regulate the supply air temperature in a way that maintains the room temperature at a desired level. Limitation of the supply air temperature (min. temp. and max. temp.) ensures that the supply air temperature is maintained within the set range. Default parameters for room control 1. ontroller = 2 Selects cascade control 2. ascade reference = 0 Selects room control 3. ascade A = 0.5 When the sensor gets colder than given setpoint value 4. ascade B = 0.5 When the sensor gets warmer than given setpoint value 5. Min. temp. = 15 Sets lowest supply air temperature 6. Max. temp. = 25 Sets highest supply air temperature Example 1. Setpoint = Room temperature = 22 This means that the new calculated setpoint for the supply air controller is: alculated setpoint = setpoint + (setpoint room air temperature) x cascade B = 18 (18 22) x ( 0.5) = 16.

23 Integrated ontrol Equipment uro Supply air unit VEKA ONTROL FUNTIONS Outdoor temperature compensation The setpoint temperature for supply air can be adjusted up or down depending on the outdoor temperature. By setting a higher set point value both on cold winter days and hot summer days indoors comfort is improved. In summer, this will increase energy savings. Outdoor temperature compensation can not be combined with room control. Default parameters for outdoor temperature compensation 1. ontroller = 2 Selects cascade control. 2. ascade reference = 1 Selects outdoor temperature compensation. 3. ascade A = 0,05 When the sensor gets colder than given setpoint value. 4. ascade B = 0.03 When the sensor gets warmer than given setpoint value. 5. Min. temp. = 15 Sets lowest supply air temperature. 6. Max. temp. = 25 Sets highest supply air temperature. Setpoint Outdoor temperature compensation Outdoor temperature, Example 1 1. Setpoint = Outdoor air temperature = 2 This means that the new calculated setpoint for the supply air controller is: alculated setpoint = setpoint + (setpoint outdoor air temperature) x cascade A = 18 + (18 (-2)) x 0.05 = 19 Example 2 1. Setpoint = Outdoor air temperature = 28 This means that the new calculated setpoint for the supply air controller is: alculated setpoint = setpoint + (setpoint outdoor air temperature) x cascade B = 18 (18 28)) x 0.30 = Freeze protection Warning! Do not change these parameters unless it is absolutely necessary. If the unit is misconfigured the water coil can freeze up and cause water damage to property. Freeze protection is used during low outdoor temperatures to prevent the coil from freezing. When the unit is stopped, the temperature in the water coil is maintained at the setpoint to keep the unit warm. If there is a risk of freezing in the water coil the valve is controlled to open. If the temperature drops below the limit value an A-alarm is obtained, which then stops the unit. 5.4 Fan control 3-speed control (trickle, normal, boost). To change fan speed use schedules, external timer or PIR.

24 24 Supply air unit VEKA Integrated ontrol Equipment uro 6. ommunication The unit can communicate with a Building Management System (BMS) via Modbus (RS485 and TP/IP). No other protocols are supported. 6.1 MODBUS, RS485 See table below for connection of Modbus. For more information, see the separate Modbus ins omponent Terminal onnection Note Modbus, RS485 Modbus REF - A - B 6.2 MODBUS, TP/IP The unit has a built-in Ethernet card for connection to a LAN. onnect the Ethernet cable (RJ45) to the connector on top of the unit. 6.3 WEBSERVER There is a built-in webserver in the uro control system. This makes it possible to read and change parameters via a web browser. To read or change the IP-address, enter menu 8.1.

25 Integrated ontrol Equipment uro Supply air unit VEKA Parameter list Incorrect parameter settings may cause malfunction and freezing damage in hot water coil. Therefore all settings has to be made by persons with necessary knowledge. Temperature Status Parameter Type of value 1) Range Unit Default value omments Supply air R Outdoor air R Extract air R Freeze protection R For unit with Hot Water oil Set point R/W Summer / Winter mode R Summer / Winter Output signal, Post Heater R % Output signal, Pre Heater R % Not for VEKA Output signal, Heat Recovery R % Not for VEKA Output signal, ooling R % ontrol mode/alculated Set point R Fan status Parameter Type of value 1) Range Unit Default value omments Supply Fan, speed R 0 or % Exhaust Fan, speed R 0 or % Air quality Parameter Type of value 1) Range Unit Default value omments O 2 value R ppm Not for VEKA System overwiev Parameter Type of value 1) Range Unit Default value omments Software version, ontrol panel R Bootloader version, ontrol panel R Software version, ontrol board R Bootloader version, ontrol board R Unit type R VEKA IP Octet 1 R Actual IP address, accessory IP Octet 2 R IP Octet 3 R IP Octet 4 R Schedules Parameter Type of value 1) Range Unit Default value omments Schedules R Active schedules, read only 1) R/W = Read and write value, R = Read only value

26 26 Supply air unit VEKA Integrated ontrol Equipment uro 7. Parameter list Settings Parameter Type of value 1) Range Unit Default value omments Set Date and Time R/W Set Language R/W Swedish Login R/W For installers and Service personnel Settings For installers and Service personnel 1. Schedule See section ommissioning Wizard See section Timer ontrol Timer control R/W See section 2.7 Timer Release Delay R/W min 0 4. Fan ontrol 4.1 Fan settings Boost Running Timer R/W Yes / No No Boost Running Time R/W min 120 Startup Time R/W s 15 Shut Down Time R/W s sec for unit with Electrical heater Fireplace R/W min 30 Not för VEKA 4.2 OP / AV Not för VEKA 5. Heating / ooling 5.1 Pre Heater Not for VEKA 5.2 Heating/ooling Temperature control option R/W = Standard, supply air control. See section = ascade control See section 5.2 Minimum Supply temp R/W Maximum Supply temp R/W ooling sequence R/W Yes/No No ooling DX R/W Yes/No No Dead zone ooling R/W Yes/No Yes Dead zone R/W Block cooling in Winter R/W Yes/No Yes Block heating in Summer R/W Yes/No Yes Post Heater R/W Yes/No Yes ascade reference R/W = Extract air control 1 = Outdoor air compensation ascade A R/W ,5 ascade B R/W ,5 Relative / Absolute temperature R/W rel/abs rel Relative or absolute temperatures in Schedule 5.3 Night ooling Not for VEKA 5.4 Defrosting Not for VEKA 5.5 ooling Recovery Not for VEKA 5.6 Summer / Winter mode urrent season mode R Summer / Winter Automatic/Manual mode R/W Auto / Manuellt Auto Manual Summer / Winter mode R/W Summer / Winter Winter 1) R/W = Read and write value, R = Read only value

27 Integrated ontrol Equipment uro Supply air unit VEKA Parameter list Parameter Type of value 1) Range Unit Default value omments 5.7 Frost protection See section 5.3 Pump stop R/W Yes/No Yes No = Pumps always running Pump Stop mode R/W 1) R/W = Read and write value, R = Read only value Summer / Winter Heating / ooling Heating / ooling onstant temp Hot Water oil R/W Low limit running temp, Set point R/W Frost Protection Alarm, Set Point R/W Air quality 6.1 O 2 ontrol Not for VEKA Heating/ooling = Heating pump is running when there is a heating demand. ooling pump is running when there is a cooling demand. Summer/Winter = Heating pump is running when the unit is in winter mode. ooling pump is running when the unit is in summer mode. Exercise of pumps every day at Alarm onfiguration 7.1 Alarm Settings Dirty Filter alarm time R/W days 0 Set to 0 to deactivate the filter alarm A and B on first Relay R/W Yes / No Yes Enable temperature alarm R/W Yes / No Yes Temperature alarm R/W Activate test of RHE belt R/W Yes / No No Not for VEKA 7.2 Alarm cathegorys Fire Alarm R/W A/B A External function Sensor Error Supply air R/W A/B A Sensor Error Outdoor air R/W A/B A Sensor Error Extract air R/W A/B A Sensor Error Frost Protection R/W A/B A For unit with Hot Water coil Sensor Error Defrost R/W A/B B Not for VEKA Sensor Error AI10 R/W A/B B Not for VEKA Supply Fan Error R/W A/B A Not for VEKA Extract Fan Error R/W A/B A Not for VEKA Dirty Filter Alarm R/W A/B B Not for VEKA Preesure switch RHE R/W A/B B Not for VEKA RHE Failure R/W A/B B Not for VEKA Filter Alarm Supply R/W A/B B Filter Alarm Extract R/W A/B B Not for VEKA Electrical Heater Error R/W A/B B Pump Heater Malfunction R/W A/B B Frost Protection R/W A/B B Alarm ooling R/W A/B B Pump ooling Malfunction R/W A/B B Temperature alarm R/W A/B A RHE belt alarm R/W A/B A Not for VEKA

28 28 Supply air unit VEKA Integrated ontrol Equipment uro 7. Parameter list Parameter Type of value 1) Range Unit Default value omments 7.3 Alarm Delays Fire Alarm R/W s 2 External function Sensor Error Supply air R/W s 5 Sensor Error Outdoor air R/W s 5 Sensor Error Extract air R/W s 5 Sensor Error Frost Protection R/W s 5 For unit with Hot Water coil Sensor Error Defrost R/W s 5 Not for VEKA Sensor Error AI10 R/W s 5 Not for VEKA Supply Fan Error R/W s 2 Not for VEKA Extract Fan Error R/W s 2 Not for VEKA RHE Failure R/W s 2 Not for VEKA Filter Alarm Supply air R/W s 60 Filter Alarm Extract air R/W s 60 Not for VEKA Electrical Heater Error R/W s 2 Pump Heater Malfunction R/W s 2 Frost Protection R/W s 2 Alarm ooling R/W s 2 Pump ooling Malfunction R/W s 2 Temperature alarm R/W min 10 RHE Belt Alarm R/W s 60 Not for VEKA 7.4 ontact function DI1 Timer 1 R/W NO/N NO DI2 Timer 2 R/W NO/N NO DI3 RHE Rotation Guard R/W NO/N NO Not for VEKA DI4 Defrost pressure switch R/W NO/N NO Not for VEKA DI5 Filter Alarm Supply air R/W NO/N NO DI6 Filter Alarm Extract air R/W NO/N NO Not for VEKA DI8 Fire Alarm R/W NO/N N DI9 ooker Hood R/W NO/N NO Not for VEKA DI7 Alarm Heater R/W NO/N NO N with Electrical Heater DI10 Alarm cooling R/W NO/N NO 8. onfigure 8.1 IP Address R/W Static / Dynami Dynamic Subnet mask R/W Gateway R/W Static = Manual Dynamic = Automatic via DHP 8.2 Menu configure Log to USB R/W Yes / No No Only for troubleshooting Unit Type R eo Top Auto logout time R/W min 10 Threshold Heater R/W % 0 For Installers and Service Personnel Threshold ooling R/W % 0 For Installers and Service Personnel Threshold Heat Exchanger R/W % 0 For Installers and Service Personnel Threshold External Fan R/W % 5 For Installers and Service Personnel 8.3 Screen saver Screensaver R/W On/Off On Timeout R/W min Modbus BMS Modbus Slave Address R/W Baudrate R/W 9.6, 19.2, ,2 Parity R/W None, Even, Odd None Data bits R/W 7,8 8 Stop bits R/W 1,2 1 1) R/W = Read and write value, R = Read only value

29 Integrated ontrol Equipment uro Supply air unit VEKA Parameter list Parameter Type of value 1) Range Unit Default value omments 8.5 Mac address Mac address R 8.6 Reset Soft reset Reset All values are reset except adjusted air flows and setpoints Factory reset Reset All values are reset 8.7 Login settings Auto Logout R/W Yes/No Yes Set Password 1 R/W To change password 8.8 About Software Version ontrol Panel R Software Version ontrol Board R Bootloader version ontrol Board R 9. Save settings Saves adjusted values Slot 1 Slot 2 Slot 3 Slot 4 Slot Load settings Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Upload saved adjusted values from ontrol Panel 11. Save settings to SD opies saved values to SD Slot 1 Slot 2 Slot 3 Slot 4 Slot Load settings from SD Loads saved values from SD Slot 1 Slot 2 Slot 3 Slot 4 Slot Test For Service Personnel 13.1 Inputs 13.2 Outputs 14. Logout 1) R/W = Read and write value, R = Read only value

30 30 Supply air unit VEKA Integrated ontrol Equipment uro 8. Declaration of onformity Bilaga II A Försäkran om maskinens överenstämmelse Declaration of onformity med EG:s Maskindirektiv / with the EU Directive for Machinery, 2006/42/E EG:s EM Direktiv / with the (EM) Directive, 2014/30/EU EG:s Lågspänningsdirektiv LVD / with the Low Voltage Directive(LVD), 2014/35/EU EG:s Direktiv för energirelaterade produkter / EU Directive for Energy related Products ErP 2009/125/E Tillverkaren Fläkt Woods AB Manufacturer Fläktgatan Jönköping Försäkrar härmed att: Herewith declares that: Produkten Typ / Type: Ventilationsaggregat / Ventilation Unit Product Fabrikat / Manufacturer: Fläkt Woods AB Varunamn / ommercial name: VEKA Maskinen är konstruerad och tillverkad i enlighet med följande standarder, i tillämpliga delar: The machine is designed and manufactured in accordance with the following standards, in relevant parts. EN ISO EN EN EN Maskinsäkerhet Allmänna konstruktionsprinciper Riskbedömning och riskreducering Safety of machinery General principles for design- Risk assessment and risk reduction Maskinsäkerhet Maskiners elutrustning, Del 1: allmänna fordringar Safety of machinery; electrical equipment of machines; general requirements Elektromagnetisk kompatibilitet (EM) - Del 6-2: Generella fordringar - Immunitet hos utrustning i industrimiljö Electromagnetic compability (EM) - Part 6-2: Generic standards Immunity standard for industrial environments. Elektromagnetisk kompatibilitet (EM) - Del 6-3: Generella fordringar - Emission från utrustning i bostäder, kontor, butiker och liknande miljöer. Emission standard for residential, commercial and light-industrial environments. För produkten har riskanalys upprättats enligt krav i Maskindirektivet. / A risk analysis has been made according to requirements of the Directive for Machinery. Behörig Authorized Att sammanställa teknisk dokumentation: To prepare technical documentation: Ann-Sofie Andersson Konstruktion / Design Fläkt Woods AB, Housing Gesällgatan Enköping Försäkran gäller endast om installation av aggregatet skett enligt Fläkt Woods instruktioner och förutsatt att inga ändringar gjorts på aggregatet. The declaration applies only to the installation made according to Fläkt Woods instructions and assuming no changes made to the unit. Enköping Matthias Junker, Produktionschef / Operations Manager, Fläkt Woods AB, Enköping Fläkt Woods AB Postal Address Street Address Telephone Telefax Reg. no: Fläkt Woods AB Fläktgatan 1 Nat Nat S Jönköping Int Int Reg. office: Sweden Jönköping SE_GB_VEK_ Declaration of onformity(2a) doc

31

32

33

34 FWG-VEKA ver ontrol equipment-gb GB opyright 2016 Fläkt Woods Group We bring better air to life VEKA ver 9965GB With over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits Air omfort and Fire Safety. With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects. Our product brands such as SEMO, eq, eq Prime, JM Aerofoil, Econet, Veloduct, Optivent, Optimix, Econovent and leanvent are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.» To learn more about our offering and get in contact with your nearest sales representative please visit

eco TOP INSTALLATION AND MAINTENANCE MANUAL

eco TOP INSTALLATION AND MAINTENANCE MANUAL eco TOP INSTALLATION AND MAINTENANCE MANUAL 2 eco TOP - Installation and Maintenance Manual CONTENTS Page 1. SAFETY INSTRUCTIONS...3 VDI 6022...3 2. DESCRIPTION OG THE UNIT...4 3. TRANSPORT AND PLACEMENT...5

More information

eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL

eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL AIR COMFORT AIR TREATMENT ENERGY RECOVERY eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL eco PREMIUM - Installation & Maintenance REDA 2 CONTENTS 1. SAFETY STANDARDS AND CE MARKING...

More information

VEKA ver C SUPPLY AIR UNIT IINSTALLATION AND MAINTENANCE

VEKA ver C SUPPLY AIR UNIT IINSTALLATION AND MAINTENANCE VEKA ver C SUPPLY AIR UNIT IINSTALLATION AND MAINTENANCE 2 Supply air unit VEKC - Installation and Maintenance CONTENT Page 1. SAFETY INSTRUCTIONS... 3 2. INSTALLATION 2.1 Storage...4 2.2 Lift and transport...4

More information

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation Air Comfort Air Treatment Housing ventilation MODBUS RS485» Technical instructions 2 Modbus RS485 Technical instructions Description, Connections, Presentation, decimals Description RS485 has two connections,

More information

Heat recovery unit RDKS. Technical instructions for installation, operation and maintenance

Heat recovery unit RDKS. Technical instructions for installation, operation and maintenance for installation, operation and maintenance Software version: 1.19 June 2013 Contents Maintenance (for the user) Operation and Maintenance - Functions... 3 Managing the control panel functions... 4 Control

More information

HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS 2 Heat recovery unit RDKS - Technical manual CONTENTS OPERATION AND MAINTENANCE (FOR USER) Functions, system design,

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS 2 Heat recovery unit RDAF - Technical manual CONTENTS OPERATION AND MAINTENANCE (FOR USER) Functions, electrical

More information

MODBUS RS485 TECHNICAL INSTRUCTIONS

MODBUS RS485 TECHNICAL INSTRUCTIONS MODBUS RS485 TECHNICAL INSTRUCTIONS 2 Modbus RS485 - Technical instruction DESCRIPTION, CONNECTIONS, PRESENTATION, DECIMALS DESCRIPTION RS485 has two connections, A and B. Often there is also a protective

More information

Manual for the integration in BMS/GTC

Manual for the integration in BMS/GTC Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2

More information

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX 04-120 1. General The TBLZ-2-66 accessory is a control system incorporated into a

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Technical data Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180

More information

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW AIR COMFORT AIR MANAGEMENT IPSUM IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW IPSUM SYSTEM OPTIMIZER IPSUM SYSTEM ROUTER IPSUM CONNECTION UNIT IPSUM from Fläkt Woods a giant step forward!

More information

Z24 Wireless Zone Controller Professional Installation Guide

Z24 Wireless Zone Controller Professional Installation Guide Pelican Wireless Systems Pelican Wireless Systems Wireless Zone ontroller Professional Installation Guide Pelican Wireless Systems, 2655 ollier anyon Rd. Livermore, A 94551 Phone: 888.512.0490 Email: support@pelicanwireless.com

More information

SAVE VTR 500. Installation and Service. Document in original language A001

SAVE VTR 500. Installation and Service. Document in original language A001 SAVE VTR 500 Installation and Service Document in original language 211477 A001 GB Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without notice.

More information

VEKA Integrated Control

VEKA Integrated Control VEKA Integrated Control Contents Overview...4 Properties...4 Safety...4 Requirements regarding personnel for installation and start-up...4 Safety regulations...4 Maintenance and service...5 Environmental

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-038 08/16 FEATURES SPECIFICATION > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) >

More information

SAVE VSR 150/B. Installation and Service. Document in original language A001

SAVE VSR 150/B. Installation and Service. Document in original language A001 SAVE VSR 150/B Installation and Service Document in original language 211456 A001 GB Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without

More information

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Topvex SR03, SR04, SR06 Compact Air Handling Unit Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

SAVE VTC 200. Installation and Service. Document in original language A002

SAVE VTC 200. Installation and Service. Document in original language A002 SAVE VTC 200 Installation and Service Document in original language 211461 A002 GB Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without notice.

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Overview Modbus can access single adresses or multiple addresses simultaneously; either reading or writing

More information

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS 2 Air Heating unit ACJB - Technical manual CONTENTS OPERATION AND MAINTENANCE (FOR USER) System, functions, main components...3

More information

BLAUAIR AUTOMATIC CONTROL SYSTEM

BLAUAIR AUTOMATIC CONTROL SYSTEM BLAUAIR AUTOMATIC CONTROL SYSTEM S30 (KVENT, TH-TUNE) S31 (KVENT) S32 (KVENT, PGDE) EN USER S MANUAL CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 5 Installation and set-up... 6 Control...

More information

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions Original instructions SIRe Competent Air Curtains Water With quick guide SIReAC SE... 2 GB... 19 DE... 36 FR... 54 For wiring diagram, please see p.71-73 For more languages, please see www.frico.se SIRe

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

Topvex SF02-SF12 Air Handling Unit

Topvex SF02-SF12 Air Handling Unit Topvex SF02-SF12 Air Handling Unit Installation instructions Document in original language 130324 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1904 READ AND SAVE THESE INSTRUCTIONS BASIC-PLC CONTROLLER MANUAL For all Condair desiccant dryer with equipped with Basic- PLC valid from version: PLC-35/PLC-45 18.04.03 Dehumidification

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs

More information

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans Air Comfort Air movement Duct & Box Fans GLEC exhaust FAN» Technical CATALOUGE Technical catalouge Exhaust Fan GLEC 2 Contents Exhaust fan - GLEC... 3 Performance Data...4 Fan chart-explanation and definitions...

More information

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel PU SENS 01 CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 4 Overall dimensions [mm]... 4 Mounting and set-up... 5

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Sensor Control Panel

Sensor Control Panel USER S MANUAL PU SENS 01 Sensor Control Panel V55-6EN-03(SENS).indd 1 18.08.2015 10:37:16 2 PU SENS 01 CONTENTS Safety Requirements 2 Main Technical Data 3 Control Panel Mounting 3 Control Panel Operation

More information

Networkable Fan Coil Controller Specification and Installation Instructions

Networkable Fan Coil Controller Specification and Installation Instructions Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat

More information

ggg Air Handling Unit RT 700/1000S-EC-RS INSTALLATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE

ggg Air Handling Unit RT 700/1000S-EC-RS INSTALLATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE ggg INSTALLATION DESIGN & TECHNICAL INFORMATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE Exhaust air filter, article No: Q4871 Supply air filter, article No: Q4872 June 2013 1 CONTENTS Page Installation

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

TopMaster Air Handling Unit

TopMaster Air Handling Unit TopMaster Air Handling Unit Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Installation and operation manual Table of contents Page 1. Supplied accessories and intended use... 1 2. General layout and setup of a system... 2 3. Installation...

More information

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans Air Comfort Air movement Duct & Box Fans GLEB KITCHEN exhaust FAN >> Installation and Maintenance Kitchen Exhaust Fan GLEB Installation and Maintenance Important Information, Safety notes, Technical Description

More information

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans! AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range

More information

Built-on speed controller for GMPM plug fan with permanent magnet motor

Built-on speed controller for GMPM plug fan with permanent magnet motor Air Comfort air comfort Centriflow 3D Plug fan GMPM Built-on speed controller» Installation and Operation Built-on speed controller for GMPM plug fan with permanent magnet motor Content Page 1. Introduction...

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating TPOne-B Electronic Programmable Room Thermostat Danfoss Heating Installation Guide TPOne is an intelligent programmable heating control made easy. TPOne includes features which are designed to save energy.

More information

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3005925_2018-02-05.fm EXcon zone control Control for up to 4 individual zones EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk OJ-Air2

More information

SYX660 Commissioning Guide V Page 1 of 55

SYX660 Commissioning Guide V Page 1 of 55 Page 1 of 55 Table of Contents 1. INTRODUCTION... 4 1.1 Important Information Regarding Product Safety... 5 1.2 Notes on Disposal... 5 1.3 INPUTS... 6 1.4 ANALOGUE OUTPUTS... 7 1.5 OUTPUTS... 7 1.6 WEB

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

CLEVER CONTROL Version: V3

CLEVER CONTROL Version: V3 CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,

More information

USER MANUAL. OPTIMA 312 ES960C circuit board

USER MANUAL. OPTIMA 312 ES960C circuit board USER MANUAL OPTIMA 312 ES960C circuit board TABLE OF CONTENTS 1. Installation of Optima Design... 3 1.1 Installation of the Control Panel... 3 1.2 Mounting... 3 2. Control Panel... 4 3. Installation...

More information

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17 Q-SMART MODBUS KIT Modbus Protocol & Parameters Cod.001085120EN rev.a ed.08/2018 Q-SMART Software Version AE17 Index 1 Modbus Protocol on Q-SMART... 4 1.1 Broadcasting... 4 1.2 Data Protection... 4 1.3

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

AirTrak. Digital Control System. User Manual. Touchscreen Systems

AirTrak. Digital Control System. User Manual. Touchscreen Systems AirTrak Digital Control System User Manual Touchscreen Systems Rev. 10-29-15 1 2 Table of Contents OVERVIEW... 8 NETWORKING... 9 AIRTRAK DEFAULT SETTINGS... 9 Unit Operating Modes... 10 MRT Controls...

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

MCD User Manual

MCD User Manual 6759 08/5 ALA MCD5-999 User WWW.COMFORTHEAT.COM.AU < Contents > Contents Menu Overview................ 3 Introduction.................. Startup Wizard /2.............. 5 Startup Wizard 2/2..............

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

C-series Controllers for air handling systems

C-series Controllers for air handling systems C-series Controllers for air handling systems Corrigo, C-series, is a range of digital controllers for air-handling systems designed to be easy to use and operate, having a large capacity, and a high degree

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

ENTOUCH ONE USER GUIDE

ENTOUCH ONE USER GUIDE ENTOUCH ONE USER GUIDE v4.0 MEASURE. MANAGE. SAVE. Contents Getting Started 3 Installation 7 Using the Setup Wizard 11 Using the Home Screen 12 Using the Main Menu 16 The Setup Menu 19 Using the Web Management

More information

SYX66x Commissioning Guide V Page 1 of 61

SYX66x Commissioning Guide V Page 1 of 61 Page 1 of 61 Table of Contents 1. INTRODUCTION... 4 1.1 Important Information Regarding Product Safety... 5 1.2 Notes on Disposal... 5 1.3 INPUTS... 6 1.4 ANALOGUE OUTPUTS... 7 1.5 OUTPUTS... 7 1.6 WEB

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold

More information

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t Swegon Home Solutions CASA R2 Smart Installation, commissioning and maintenance instruction R2_a_EN-t Contents Technical Guide for design engineers, installation engineers and service personnel The section

More information

Installation and User Instructions

Installation and User Instructions Installation and User Instructions The Informant is a self-contained alarm and logging device that uses the cellular phone network. Text message alarms are sent up to five cell phones. Events are logged

More information

SAVE VTR 250/B. User Manual. Document in original language A001

SAVE VTR 250/B. User Manual. Document in original language A001 SAVE VTR 250/B User Manual Document in original language 211474 A001 GB Copyright Systemair UAB All rights reserved E&OE Systemair UAB reserves the rights to change their products without notice. This

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Installation and operation manual Table of contents Page. Supplied accessories and intended use.... General layout and setup of a system... 3. Installation... 3 3.. Mounting

More information

Installation and Service

Installation and Service Systemair is not liable or bound by warranty if these instructions are not adhered to during installation or service. 2013 Copyright Systemair AB Systemair AB can accept no responsibility for possible

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS AIR COMFORT AIR TREATMENT AIR HANDLING UNITS eq PRIME» ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX ENVIRONMENT ECONOMICAL EXPERTISE In its simplicity the e 3 captures what makes us attractive

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information

C User manual

C User manual C10...40 User manual Introduction COORIGO is a completely new range of controllers which has been designed to be easy to use and operate. The controllers have a display and built in panels for operation

More information

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D CENTRIFLOW 3D Plug fan GMEC >> Installation and Maintenance air comfort CentriFlow 3D 2 Plug Fan CentriFlow 3D GMEC Installation and Maintenance Important Information, Safety notes, Technical Description

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES Original instructions SIRe Advanced Air Curtains Electric With quick guide SIReAA SE... 2 GB... 22 DE... 42 FR... 62 ES... 82 IT... 102 NL... 122 NO... 142 PL... 162 RU... 181 For wiring diagram, please

More information

Modbus RTU RS485 Manual

Modbus RTU RS485 Manual Modbus RTU RS485 Manual AUTOMATED FUEL MAINTENANCE SYSTEMS FTI-5A, FTI-10A, FTI-20A FUEL TECHNOLOGIES INTERNATIONAL 06/10/2014 Rev B - Fuel Technologies - Modbus The Modbus Communications Setup Button

More information

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Topvex SR 09, 11, Topvex TR Compact Air Handling Units Topvex SR 09, 11, Topvex TR 09-15 Compact Air Handling Units Installation instructions Document in original language 125593 A003 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves

More information

Application description

Application description Application description Application description Hersteller KNX Touch Control Hager Displays Touch Displays ETS Touch Control Order number Product designation Application programme TP product SWDT03 WDT030

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch Modbus Datasheet Application Security Advice Caution LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room

More information

Pre-programmed room controller with communication

Pre-programmed room controller with communication revision 02 2016 RC-C3 Pre-programmed room controller with communication RC-C3 is a complete pre-programmed room controller from the Regio Midi series intended to control heating and cooling in a zone

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

Sauter flexotron 800 ventilation Manual

Sauter flexotron 800 ventilation Manual Manual P100012082 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties as regards the contents

More information

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions KNCT2-808 KN Series Gas-fired direct vent Cast iron boilers Models KN-6, -10, -20 only (HeatNet control firmware edition 45 ) Control manual Control adjustment and Operation instructions Also read and

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

SIRe Advanced Air Curtains Water Ambient, no heat

SIRe Advanced Air Curtains Water Ambient, no heat Original instructions SIRe Advanced Air Curtains Water Ambient, no heat With quick guide SIReAA SE... 2 GB... 23 DE... 44 FR... 65 ES... 86 IT... 107 NL... 128 NO... 149 PL... 170 RU... 191 For wiring

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information