ST76/96 series instructions
|
|
- Wilfrid Moody
- 5 years ago
- Views:
Transcription
1 ST76/96 series instructions 1. Characteristics: 6 bit counter, timer, meter meter. 6 digit counting and timing machine. The counter relay has R, N, C, F, B preset functions. The timer relay has 4 types of output. Blackout memory function. The measurement is accurate and easy to read, and its anti-interference ability is strong. The two channels can be independent relay alarm output. Input, switch, NPN sensor with rotary encoder Input With RS485 MODBS communication interface Read and write with Bluetooth interface 2. model&meaning ST76/96-C Counter&Meter meter ST76/96 - T timer ST76/96 - CZ count meter general T76/96 - CT counting timer ST76/96 - CP counting meter batch 3. Specification
2 4. wiring connection proximity switch 15:brown 12:black 14:blue Encoder 15:power 12:A phase 13:B phase 14:ground 5.Relay action mode description
3 R N C F B The count process shows that the value reaches the set value relay output. After the delay "T" time, the relay returns, the count value is recovered at the same time, and the count is restarted. When the value of the counting process reaches the set value, the output of the relay is kept constant until the manual or external signal is reset, the relay is reset, counting value is reset, and the count is started again. The relay automatically returns after the count process shows the value of the relay output, and the value of the count is immediately reset, and the delay time is T. When the count process shows that the value reaches the set value relay output, the count value continues to rise until the manual or external signal is used. Reset, relay return, count value again zero, start counting again When the count process shows that the value of the relay is up to the set value relay output, the relay is disconnected when the set is less than the set value, and the relay is manual or External signal reset, relay reversion, count value zero ST76- T multi-function time relay Parameter setting and output action diagram A L 1 output alarm setting range (0-99 days 24 hours 59 minutes) Factory default A L 2 output alarm setting range (0-99 days 24 hours 59 minutes) Factory default Note: under the working state, press the " " key "and enter the AL1 alarm set directly."
4 Set, press " " key to select the modified bits, and the key modifies the bit.press "SET" to enter the AL2 alarm set, and then press SET to exit one Level menu modification. For example: a cumulative way down timer (C P 1 input Down, C P 2 input to accumulate, when added to the maximum value of the instrument Automatic A L 2 alarm output, input signal is useless, A L 2 output time It's one second, and the way it works is to start counting the time. Down to the Minimum instrument automatic alarm A L 1 output, input signal is useless, A L 1 output time is 1S, work for the electricity meter started down SC1=0 instrument (minutes and seconds down), SC2=0 (time division second tired Add), the initial value P R E 1 is set to 99 H 59 M 59 S, initial value P R E 2 set 00 H 00 M 00 S, A L 1 = 00 H 00 M 00 S, A L 2 = 99 H 59 M 59 S, A L 1 relay output time T I A 1 = 1 sec, A L 2 relay time T I A 2 = 1 sec, O U T 1 (A L 1) relay output amplifier = 1, O U T 2 (A L 2) relay Output type C = 1, N = 3 (A L 1 A L 2 accumulation down. ) Timer setting diagram 6 bit timer two level parameter setting (function setting)
5 for 3s Two level parameter entrance password, enter "000001", enter After the two level parameter menu, the instrument is out of the working state. The minimum time setting unit (0, 1, and no time every minute The default of 2, day time is 0. The minimum time setting unit (0, 1, and no time every minute The default of 2, day time is 0. Initial value 1 set < ), non programming Reload the initial value by the "RST" key and open from "0". This value is defaults to 6 "0" at the beginning of the count. Initial value 2 set < ), non programming Reload the initial value by the "RST" key and open from "0". This value is defaults to 6 "0" at the beginning of the count. minutes) A L 1 output alarm set range (0-99 days 24 hours and 59 Clock) when the measured value is less than this value when the AL1 output alarm output, down at The default is Al2 output alarm set range (0-99 days 24 hours 59 minutes A L 2 output alarm when the measured value is greater than this value, the default is
6 defaults to 5 seconds. A L 1 alarm relay output time setting ( seconds) seconds. A L2 alarm output time setting ( seconds)defaults 5 and 3. ways) A L 1 alarm AL1 relay operation mode selection (1. mode2. ways and 3. mode) AL2 alarm AL2 relay working mode selection (1. mode2. mode Combinatorial selection 0: one way combined output (alarm one follow the alarm two) 1: the two routes are accumulated and lost. 2: two independent transmission down 3: two A L 1 A L 2 accumulation independent output down. (two separate output alarm one is separated from alarm two) Factory default 0 ST76-C meter meter 6 bit counting, meter, first class parameter setting (alarm value setting)
7 First section output forecast 1 set range ( )When the display value is greater than this value, A L 1 output alarm and factory default Second segment output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default Note: under the working state, press the " the alarm. " key to enter the first section of Set, press the " " button to select the bit to be modified, and the key modifies it. Bit, press "SET" to enter the second alarm set or exit one. Level menu modification, in programming state, press the "EXT" key to exit the first level Menu settings Give an example: The device uses a rotary encoder input, with a circle of 1000 pulses. The circumference of the shaft is 0.3 meters, after a decimal point, the 2 bits are displayed, and the main alarm is made.the AL2 is 20 meters, and the delay is automatically reset by 5 seconds. "0" began the plan, the warning AL1 of 19 meters, that is, ahead of time 1 meter warning, sampling frequency is 3000 pulses per second, set up As follows: 1. The first level menu AL1 is set to 19, and AL2 is set to 20 The 2. two level menu L O C K menu input password , will PRE is set to "000000", and T I M 1 is set to 5, TI M 2 is set to 5, O U T 1 is set to 0 (R mode),out2 is 0 (R mode), and the C P sampling speed is set to 3,
8 that is 3000 pulses per second. 3. When the instrument is used for length measurement and control, the ratio calculation method is:the number of pulses of a circumference divided by an encoder (or a meter wheel). 0.3/1000= if the measurement and display unit is rice and centimeter, then DPSET The value is adjusted to 0. If the millimeter is to be displayed, At least 3 bits of = are left after the display value decimal point 5. if it is found that the display value of the instrument does not coincide with the actual value, such as error 10 meters, showing 100 meters, the actual value of 110 meters, the calculation method is: /X=100/ /X= X= / X= , is the latest multiplier value 6 bit counting, meter, two level parameter setting (function setting) for 3s The two level parameter entrance password, input "000001", after entering the two level parameter menu, the instrument exit the working state. Count ratio setting ( ) out of factory default 1 The decimal point is set, according to the mobile decimal point position.set (the position of the mobile decimal point determines the measuring range of the instrument) Initial value setting ( ),The default of the factory is 6 "0"
9 First section output forecast 1 set range ( ) When the display value is greater than this value, A L 1 output alarm and factory default Second segment output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default Alarm 1 output time setting ( seconds)factory default 5 Alarm 2 output time setting ( seconds)factory default 5 Alarm 1 output mode selection ((0. R mode 1. N mode 2.) C mode 3.F mode 4. B mode) factory default 0. Alarm 2 output mode selection (0. R mode 1. N mode 2. C mode 3.F mode 4. B mode) factory default 0 Select the factory default 0 for counting frequency "0" is 5PCS /S, "1", "20PCS/S," "3" for 3000PCS/S "4" is greater than 3000PCS/S) "2" 200PCS/S Combinatorial selection 0: one way combined output (alarm one follow the alarm two) 1: the two routes are accumulated and lost.
10 2: two independent transmission down 3: two AL1 down AL2 cumulative independent output. (A: two separate output alarms are separated from the alarm two, B: when the amount or batch is displayed, the instrument has only one way Output, that is, CN=0.) factory default 0 Input type selection: 0. ordinary switch signal, 1. encoder input. ST76-C counter & meter 6 bit counting, meter, first class parameter setting (alarm value setting) Push First section output forecast 1 set range ( )When the display value is greater than this value, A L 1 output alarm and factory default Second segment output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default Note: under the working state, press the " " key to enter the first section of the alarm. Set, press the " " button to select the bit to be modified, and the key modifies it. Bit, press "SET" to enter the second alarm set or exit one.level menu modification, in programming state, press the "EXT" key to exit the first level Menu settings Fox example: The device uses a rotary encoder input, with a circle of 1000 pulses.the circumference of the shaft is 0.84 meters, after a decimal point, the 2 bits are
11 displayed, and the main alarm is made. The AL2 is 20 meters, and the delay is automatically reset by 5 seconds."0" began the plan, the warning AL1 of 19 meters, that is, ahead of time1 meter warning, sampling frequency is 3000 pulses per second, set up As follows: 1. The first level menu AL1 is set to 19, and AL2 is set to The 2, two level menu L O C K menu input password , will PRE is set to "000000", and T I M 1 is set to 5,TI M 2 is set to 5, O U T 1 is set to 0 (R mode),out2 is 0 (R mode), and the C P sampling speed is set to 3, that is 3000 pulses per second. 3. When the instrument is used for length measurement and control, the ratio calculation method is:the number of pulses of a circumference divided by an encoder (or a meter wheel). 0.84/1000= if the value of the measurement is only to be displayed in centimeters, then DPSET The value is adjusted to if it is found that the display value of the instrument does not coincide with the actual value, such as error 10 meters, showing 100 meters, the actual value of 110 meters, the calculation method is: /X=100/ /X= X= / X= , is the latest multiplier value. for 3s The two level parameter entrance password, input "000001", after entering the two level parameter menu, the instrument exit the working state. Count ratio setting ( ) out of factory default 1 Set the decimal point, press the position of the moving decimal point. (the position of the moving decimal point determines the measuring range of the instrument)
12 Initial value setting ( ) and factory default of 6 "0" The first 1-10 groups select the output forecast police, A L 1 S E T setting range (1-9) When the display value is equal to the output of the 01 instrument A L 1 S E T, when the display value is displayed Equal to 02 instruments A L 1 S E T two sets output, when the instrument display value The 05 instrument A L 1 S E T is the output of 5 sets, and the factory default 01. Alarm 1 output time set ( seconds) out of factory default 5 Second stage output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default Alarm 2 output time set ( seconds) out of factory default 5 Alarm 1 output mode selection ((0. R mode 1. N mode 2.)C mode 3.F mode 4. B mode) factory default 0. Alarm 2 output mode selection (0. R mode 1. N mode2. C mode 3.F mode 4. B mode) factory default 0 Select the factory default 0 for counting frequency "0" is 5PCS /S, "1", "20PCS/S," "3" for 3000PCS/S "4" is greater than 3000PCS/S)
13 "2" 200PCS/S Combinatorial selection 0: one way combined output (alarm one follow the alarm two) 1: the two routes are accumulated and lost. 2: two independent transmission down 3: two AL1 down AL2 cumulative independent output. (A: two separate output alarms are separated from the alarm two, B: when the amount or batch is displayed, the instrument has only one way Output, that is, CN=0.) factory default 0 Input type selection: 0. ordinary switch signal, 1. encoder input. ST76- CT counter timer 6 bit counting and one level parameter setting (alarm value setting) Push A L 1 output alarm (count output) setting range ( ) when the measured value is greater than this value, A L 1 output alarm.recognize A L 2 output alarm (time output) set range (0-99 hours 59 minutes and 59 seconds) when the measured value is greater than this value, A L 2 output alarm output Factory default Note: press the " " key "" under the work state and enter the AL1 alarm set directly.
14 Click the button to select the bit to be modified, and the key changes the bit. "SET" enters the AL2 alarm value setting, and then press SET to exit the first level Menu modification For example: counting timer setting (short circuit of CP1 and COM to count signal input port, CP2 and COM short circuit as timing signal input port) The counter SC1=0 count, SC2=0 cumulative time, initial PRE1=0, initial PRE2=0.AL1 count alarm timer value is set to 5000 AL2 alarm value is set to 00 hours and 0.59 minutes.al1 count alarm time TIA1 is set to 1, AL2 times the alarm time setting TIAL 1, AL1 count output mode OUT1=0, AL2 timing output OUT2=1. When the input signal on the display meter, the cumulative value, lower cumulative display timing value. Count the cumulative time down set map for 3s Two level parameter entrance password, input " ", after entering the two level parameter menu, the instrument is out of work state Count: 0. count 1. count down, the default 0. fastest 20 times per second. Time: 0. cumulative time, 1. down time, default 0.
15 The count initial value is set by < ), and the default is 6 "0". The initial value of the timing is set < 0-99 hours, 59 minutes and 59 seconds), and the default is 6 "0" The count output alarm value is set , the default 50. The timing alarm value is set for 0-99 hours, 59 minutes and 59 seconds, and the default is 59 seconds. The output time of the count A L 1 relay is set:( seconds) Timing A L 2 relay output time setting:( seconds) Count output mode selection ((0. R mode 1. N mode 2. C mode 3. F mode 4. B mode) Timing output selection (1. mode 2. mode 3. mode 4. mode (when O U T 2 = 4, instrument can display A L 3 and T C L R menu.) The counting signal interval time is set, seconds, the default 5 seconds. A L 2 relay output auto reset T C L R setting 0, A L 2 follow Electrical output manual reset T C L R setting 1, factory default 0.
16 ST76- CP batch meter meter 6 bit counting, meter, first class parameter setting (alarm value setting) Push First section output forecast 1 set range ( ) A L 1 output alarm when the display value is greater than this value, and there is no this item at the default single section of the factory. Second stage output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default Note: work under strong state according to the " " key, directly into the first alarm setting, press " " button to select the modified, modify the button, press the "S E T" to enter the second stage set the alarm value or exit the menu changes, programmed under press "E X T" key to exit a single set of dishes For example: The equipment uses rotary encoder input, a circle of 1000 pulse axis is 0.84 meters in circumference and 2 decimal display, alarm AL2 is 20 meters, delay 5 seconds automatic reset, reset after the start counting from the "0" alarm, AL1 is 19 meters, which is 1 meters in advance warning, sampling the frequency of 3000 pulses per second, parameter settings are as follows: 1. The first level menu AL1 is set to 19, and AL2 is set to level two menu, LOCK menu, enter the password , set PRE to "000000", TI M 1 set 5, TIM2 set 5, OUT1 set to 0 (R way), OUT2 is 0 (R mode), CP sampling speed is set to 3, 3000 pulse /sec 3. When the instrument is used for length measurement and control, the ratio of the ratio is calculated: the number of the perimeter divided by the encoder (or the meter wheel). That is, 0.84/1000= If the measurement display value is only centimetre, then DPSET The value
17 is adjusted to If the display value of the instrument does not coincide with the actual value, if the error is 10 meters, the display is 100 meters and the actual value is 110 meters. The calculation method is: /X=100/ /X= X= / X= , is the latest multiplier for 3s The two level parameter entrance password, input "000001", after entering the two level parameter menu, the instrument exit the working state. Count rate setting ( ) out of factory default 1 Set the decimal point, press the position of the decimal point. (the position of the mobile decimal point determines the measuring range of the instrument) The initial value is set ( ), and the factory default is 6 "0" Alarm 1 output time set ( seconds) out of factory default 5 Alarm 1 output time set ( seconds) out of factory default 5 Alarm 1 output mode selection ((0. R mode 1. N mode 2.C mode 3.F mode 4. B mode) factory default 0.
18 Alarm 2 output mode selection ((0. R mode 1. N mode 2.C mode 3.F mode 4. B mode) factory default 0. Counting frequency select factory default 0 "0" is 5PCS /S, "1" 20PCS/S, "2" 200PCS/S "3" is 3000PCS/S "4" more than 3000PCS/S). Input type selection: 0. ordinary switch signal, 1. encoder input. Batch cleaning: 0. button can not be zero, the 1. button can be zero. Note: the batch can not be changed in the working condition. It can only be changed in the downtime or into the two level menu. ST76- CZ meter meter for total amount counting 6 bit counting, meter, first class parameter setting (alarm value setting) Push First section output forecast 1 set range ( ) A L 1 output alarm when the display value is greater than this value, and there is no this item at the default single section of the factory Second stage output main alarm 2 set range ( ) A L 2 output alarm when the display value is greater than this value. Factory default
19 Note: work under strong state according to the " " key, directly into the first alarm setting, press " " button to select the modified, modify the button, press the "S E T" to enter the second stage set the alarm value or exit the menu changes, programmed under press "E X T" key to exit a single set of dishes For example The equipment uses rotary encoder input, a circle of 1000 pulse shaft circumference of 0.84 meters, after the decimal point display 2, A L 2 as the main alarm 20 meters, delay 5 seconds automatic reset, reset after the start counting from the "0", warning A L 1 is 19 meters, which is 1 meters ahead pre alarm, the sampling frequency is 3000 pulses per second, parameter setting As follows: 1, the first level menu a L 1 is set to 00 to 9. 00, 2002 is set to 0 A L. 00 2, 2, level two menu, LOCK menu, enter the password , set PRE as "000000", T I M 1 set 5, T I M 2 set to 5, O U T 1 set 0 "(R mode),o U T 2 set 0 "(R mode),the sampling speed of C P is set to 3, that is, 3000 pulses per second. 3, when the instrument is used for length measurement and control, the rate calculation is divided into the number of pulses of encoder or meter, that is, 0.84 / 1000 = if the measurement display value only needs to display a centimeter, then the value of D P S E T is adjusted to if it is found that the display value of the instrument does not coincide with the actual value, such as error 10 meters, showing 100 meters, the actual value of 110 meters, the calculation method is: / X = 100 / / X = X = / X = , is the latest multiplier for 3s The two level parameter entrance password, input "000001", after entering the two level parameter menu, the instrument exit the working state
20 Count rate setting ( ) out of factory default 1 Set the decimal point, press the position of the decimal point. (the position of the mobile decimal point determines the measuring range of the instrument) Initial value setting ( ) and factory default of 6 "0" Alarm 1 output time set ( seconds) out of factory default 5 Alarm 1 output time set ( seconds) out of factory default 5 Alarm 1 output mode selection ((0. R mode 1. N mode 2.C mode 3.F mode 4. B mode) factory default 0. Alarm 2 output mode selection ((0. R mode 1. N mode 2.C mode 3.F mode 4. B mode) factory default 0. Counting frequency select factory default 0 "0" is 5PCS /S, "1" 20PCS/S, "2" 200PCS/S "3" is 3000PCS/S "4" more than 3000PCS/S). Input type selection: 0. ordinary switch signal, 1. encoder input.
21 Batch cleaning: 0. button can not be zero, the 1. button can be zero. Note: the batch can not be changed in the working condition. It can only be changed in the downtime or into the two level menu. 1 Instruments work or exceed set value relays 2 The meter have power but not work use reset key to restart 3 Check the signal input Note: the electric instrument stay 1 second upper display SANTEN, lower display factory time such as mean 16 years 04 months in No. 25 factory. Press the SET key to enter the program, the key selected to set the bit, by changing the value of the bit. Then press the SET key to confirm the setting parameters and jump to the bottom A parameter setting state and exit programming state according to EXT! Press and hold SET and EXT key after 5 seconds to enter COD= (set the instrument is counter, timer, timing counting machine, batch, total)the COD value changed to , press SET to confirm after SET. The default display instrument on the , when SET=0.Meter meter general. 1. timer, 2 counting timing machine, 3. batches of counter. 4. total amount counter. Press SET button to confirm the top of the instrument TIME (delivery time). The default display 0 by SET in addition, if it is a two way counting timer, the first one on the right is AL1 zero button ( ), and the second on the right is AL2 zero button
22
CONTROL PANEL INSTRUCTIONS RSQ-4
CONTROL PANEL INSTRUCTIONS RSQ-4 FOR SIRAC AIR TO WATER HEAT PUMP (SINGLE COMPRESSOR, AIR TO WATER) 1) System Configuration This system is composed of mainboard and wire control panel. 146mm Φ4 4 Mainboard
More informationDryer Controller M720
User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,
More informationUser Manual. Dryer Controller M720
User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009
More informationOperating Functions Temperature Parameters
Operating Functions Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb) Fundamental Functions After powered on, no matter when the compressor is started, the time interval
More informationEasyTronic III MANUAL SERVICE
rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard
More informationSensor Control Panel
USER S MANUAL PU SENS 01 Sensor Control Panel V55-6EN-03(SENS).indd 1 18.08.2015 10:37:16 2 PU SENS 01 CONTENTS Safety Requirements 2 Main Technical Data 3 Control Panel Mounting 3 Control Panel Operation
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationFlameGard 5 MSIR HART
FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be
More informationFLOW CONTROLLER TYPE S/601
Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This
More informationUSER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel
USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel PU SENS 01 CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 4 Overall dimensions [mm]... 4 Mounting and set-up... 5
More informationMicro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e
C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationTechnicians Manual Single Compressor
Technicians Manual Single Compressor HAC-FF-D WALL PAD Operating Manual Version PCB Version V2.3.5 Version wall pad Version Manual Page 1 Contents 1. Main features 2. Main technical data 3. Wall pad 4.
More informationDX2002 OPERATING AND PROGRAMMING INSTRUCTIONS
DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings
More informationOperation Manual Fighter ProVision Software. Version: 0.0 Revision: 1
Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User
More informationCLEVER CONTROL Version: V3
CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,
More information1 DOCUMENT REVISION CONTROL ELEMENTS... 9
CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11
More informationTEMPTRON T-607 OPERATION MANUAL Version 8021 First version: 10/06/2008
TEMPTRON T-607 OPERATION MANUAL Version 8021 First version: 10/06/2008 Page 1 1. INSTALLATION 3 2. OPERATION 3 3. READING SET POINT 3 4. CHANGE OF SET POINT 4 5. SET POINTS 5 6. Hidden Set up functions
More informationUser manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort
User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.
E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration
More information2-wire Passive Intelligent Loop (LED) Display Meter
Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter
More informationContamination Meter Users Manual
RDS-80 Contamination Meter U Users Manual Version 1.01 LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com NOTE This document and the information herewith are copyrighted
More informationFCD-wire Contents. List of Figures
FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface
More informationFollett Performance Plus
Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen
More informationRefrigerated air dryers
Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...
More informationND4000 Manual Marine Hydraulics
ND4000 Manual Marine Hydraulics Version 1.0 May 2012 Page 1 Contents Line Counter Components... 3 Proximity Sensors... 3 Connecting the Proximity Sensors to the SSCD... 3 Fuse... 3 USB... 4 Computer Display...
More informationRamsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery
Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages
More informationENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE
ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...
More informationExercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE
Exercise 8 Controlling a Batch Mixing Process EXERCISE OBJECTIVE To create a ladder program for controlling a batch mixing process. To test program operation through the completion of verification steps.
More informationVT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL
Thermocouple Type BS4937 (IEC584-3): Outer / + / - BS1843 (Old UK Standard) Outer / + / - US Outer / + / - J : Iron / Copper-Nickel Black / Black / White Black / Yellow / Blue Black / White / Red VT4810
More informationUser s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com
TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:
More informationAll- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60
All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60 HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Table of Contents Features 2 Specification 3 Wiring Description
More informationGrafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: Internet: Fax:
Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark Phone: +45 45 81 23 00 Internet: www.gm.dk e-mail: gm@gm.dk Fax: +45 45 81 99 56 OPERATING INSTRUCTIONS FOR TF400 Folding Machine 2 Index
More informationFlameGard 5 UV/IR HART
FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized
More information2-wire Passive Intelligent Loop (LED) Display Meter
Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter
More informationF PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationFL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com
FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts
More informationRefrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA
Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND
More informationOPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL
ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982
More informationTrainBoss Defect Detector Displaying Detector Model No. TB-21D
TrainBoss Defect Detector Displaying Detector Model No. TB-21D Hotbox & Equipment Defect Detector for model railroads Displays 6 types of defect alarms for passing trains: hotbox, dragging equipment, high
More informationGeneral The Dryer Programmer for Windows Computers
Published Manual Number: MQYDSB01 Specified Date: 20131120 As-of Date: 20131120 Access Date: 20131120 Depth: Detail Custom: n/a Applicability: YDS Language Code: ENG01, Purpose: publication, Format: 1colA
More informationWATER HEATER ELECTRONIC CONTROLLER USER MANUAL
WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More informationALPTEC Power factor controller
ALPTEC Power factor controller I - CONNECTIONS CONTROL II - MANUAL KEYPAD SET-UP III OPERATING MODE IV - ALARMS I - CONNECTIONS CONTROL At the first power up, the ALPTEC display views --- which means no
More informationColumn swing gate turnstile CPW-321ASP
Column swing gate turnstile CPW-321ASP Product Manual Concise high efficient & fashionable Product Description: The passage consists of two units of CPW-321ASP by default. Single-gate passage by one unit
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More informationCAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software
INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45
More informationThermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery
Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions
More informationocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.
1 2 3 4 5 6 7 8 IN OFF ON + T S B J Т1 ocbridge Plus 1. FEATURES Wireless sensors receiver ocbridge is designated for connecting compatible Ajax devices to any third party wired central unit (panel) with
More informationDiagnostics and Monitoring System WEB Tool 2. User Manual
Diagnostics and Monitoring System 2 (Translation of the original documentation) User Manual S/N: Valid from: 01.05.2012 Rev.: 2.0 2 Rev. 1.... 1 1.1 General information... 1 1.1.1 Equipment... 1 1.1.2
More informationBench-Top Vacuum Oven with 28 segments programmable controller
Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully
More informationAGC 200 Advanced Gen-set Controller OPERATOR S MANUAL
Advanced Gen-set Controller OPERATOR S MANUAL Display readings Push-button functions Alarm handling Log list Document no.: 4189340607A SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...3
More informationFIRERAY 5000 range USER GUIDE
FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI
E N G L I S H FIRE ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL0EI, MI-FL0EI AND MI-FL0EI mm mm 0 mm DESCRIPTION The LT MI-FL0 Series is part of the Fire Alarm
More informationGas Detection System TOX ALARM DG2000-Garage
Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas
More informationTable of Contents SECTION PAGE
Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................
More informationRamsey Motion Monitoring Systems
Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring
More informationEasyTech.One Temperature Controller for Pellet Burner
EasyTech.One Temperature Controller for Pellet Burner Burner 1 INTRODUCTION... 3 2 ELECTRICAL CONNECTIONS... 3 3 CONTROL PANEL: USE AND FUNCTIONS... 5 3.1 LED... 5 3.2 BUTTONS... 5 3.3 ALARMS... 5 3.1
More informationMillennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.
Millennium Xtra Millennium ATMA setup and configuration guide May 16 2017 Millennium Group, Inc. 16 Tech Circle Natick, MA 01760 P: 508-655-1340 F: 508-651-2902 Millennium ATMA setup and configuration
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationIF-105 user interface (Original operating and maintenance instructions)
IF-105 user interface (Original operating and maintenance instructions) TABLE OF CONTENTS 1 General information...1 2 Design...1 2.1 LED-signals for channels...2 2.2 LED-signals for operation...2 2.3 Buttons...3
More informationFI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface
INSTRUCTION MANUAL FI6000 Fire Alarm Interface Thank you for choosing another quality product from Amperes Electronics. FI6000 is a phase evacuation controller which can be integrated with various Amperes
More informationUAS 7000 Local Management
Issue 2, October 1998 Operation UAS 7000 Local Management Includes Support for: UAS 7001 NIU UAS 7002 NIU UAS 7616 DIU UAS 7616M DIU UAS 7626 DIU General DataComm, Inc. Preface iii Local Management Access...
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More information- Data Brochure Steam Control 279
- Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the
More informationDIGITAL TEMPERATURE RELAY TR-100
LTD Research-and-Manufacture Company DIGITAL TEMPERATURE RELAY USER S MANUAL www.novatek-electro.com - 2 - Service manual is intended for getting acquaints with hardware, operation principals, modes of
More informationOperating Manual PU-27 Control Panel
EN Operating Manual PU-27 Control Panel Ver. 1.0.0.1. Contents 1 Introduction 3 2 Warranty and liability 3 3 Safety 5 4 Purpose 5 5 Control panel description 5 6 Starting control panel operation 6 7 Main
More informationTips how to use the MAS Web tool
Tips how to use the MAS Web tool Login options User name: operator You can only view data and settings etc (the only Internet option). User name: config You can do settings and view (option on Intranet)
More informationDatabase for CTS6000 MODBUS
Database for CTS6000 MODBUS Valid for: LONcard SW1.7.4B, Variable List V2.02 Version 1.08-4, 01-05-2016 Contents Contents... 2 1. Installation... 3 1.1. Installation and operating instructions... 3 2.
More informationCompod. Instruction Manual IM-COMPOD Revision: F, December 2015
Compod Programmable Control Module For 100 Series Digital Mass Flow Meters & Controllers Instruction Manual IM-COMPOD Revision: F, December 2015 CORPORATE HEADQUARTERS 5 Harris Court, Building L, Monterey,
More informationDC200 Digital Dispenser Operating Manual
DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine
More information4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485
Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm
More informationNokeval. No Manual. Model 2026 Totalizer / Batch controller for analog inputs
No 00 Nokeval Manual Model 0 Totalizer / Batch controller for analog inputs Contents Rate / Batch controller 0 for analog inputs... Dimensions... Front panel indicators and buttons... Configuration...
More informationInstallation Manual Tracker 221
Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing
More informationThe Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will
The formation Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will be working on the Blodgett XR8 Oven. All other uses are
More informationWatts Under Floor Multi-zone Controller User Manual
Watts Under Floor Multi-zone Controller User Manual Master unit RF Timer The digital wall thermostat can also use a floor temperature sensor to control minimum and maximum floor temperature, as well as
More informationSeries SHR-5620 Digital Display Volumetric Meter Operation Instruction
Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Version: 5620-110722 1. Introduction SHR-5620 Digital Display Volumetric Meter,Produced by full-automatic chip mounter with surface
More informationSAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .
CALIB CONTINUOUS SPEED INDICATOR EVALUATION UNIT ALRM 1 ALRM 2 ALRM 3 PULSE DISPLAY MESSAGES INSTRUMENT START/RESTART OVERSPEED OCCURED > UNDERSPEED OCCURED < SPEED IS
More informationDIGITAL ALARM UNIT Model ALU-AP
DIGITAL ALARM UNIT Model ALU-AP Description Digital alarm unit ALU-AP has the following characteristics: 1. Operates in MASTER or SLAVE mode. 2. It can connect with other devices through a RS485 network
More informationDashboard for Windows V1.1.0
User manual Dashboard for Windows V1.1.0 TBS Electronics BV De Factorij 46 1689 AL Zwaag The Netherlands www.tbs-electronics.com COPYRIGHT 2009 (rev1e) - 1 - TABLE OF CONTENTS 1. INTRODUCTION......................
More informationDigital MFC software V1.10
Digital MFC software V1.10 User s Manual MTI Corporation 860 South 19 th Street, Richmond, CA 94804, USA Tel: 510-525-3070 Fax: 510-525-4705 E-mail: info@mtixtl.com Web site: www.mtixtl.com Table of Contents
More informationGenerator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list
OPERATOR'S MANUAL Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More informationSCAN20 Series Gas Detection Controller
SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software
More informationNGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1
NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...
More informationFCR 05, FCR 07. Power factor correction controller. User and service manual
FCR 05, FCR 07 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationS/601 Controller Installation Manual
Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control
More informationDT968C C.T. BATH CONTROLLER
DT968C C.T. BATH CONTROLLER MANUAL (DT968C, 9-5-01) ICD/HEATEFLEX Page 1 DT968C CONSTANT TEMPERATURE BATH CONTROLLER The Model DT968C is a microprocessor based controller/timer. It monitors temperature
More informationM2M Services Ltd. RControl Alarm - Installer Manual V 1.0
M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported
More informationThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET
ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET Model: MM7100-2D Index Introduction 1 PC Setup 2-3 Bluetooth Setup 4-5 Discovery 6 USB Setup for USB instruments 7 Setting Instrument Parameters
More informationRS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use
RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based
More informationX.90 Access Control System
X.90 Access Control System ACX provides a comprehensive Access Control System and Time Attendance, which is the highest security standard in the world industry. ACX product range includes door access panel,
More informationTemperature-Relay TR210
Operating instructions Temperature-Relay TR210 Page 1 of 24 Table of contents 1. Application and Short description... 3 2. Overview of functions... 3 3. Connection Plan... 3 4. Display and operation parts...
More informationSA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting
Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller
More informationDryer Master DM510 Commissioning Guide
COMMISSIONING GUIDE Dryer Master DM510 Dryer Moisture Systems Inc. 640 Superior Drive Waterloo, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com
More informationHP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS
HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring
More informationModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.
ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page
More information