NFPA 79 - Second Draft Meeting July 8-10, DoubleTree Hotel, Portland, ME

Size: px
Start display at page:

Download "NFPA 79 - Second Draft Meeting July 8-10, DoubleTree Hotel, Portland, ME"

Transcription

1 National Fire Protection Association 1 Batterymarch Park, Quincy, MA Phone: Fax: AGENDA NFPA TECHNICAL COMMITTEE ON ELECTRICAL EQUIPMENT OF INDUSTRIAL MACHINERY NFPA 79 - Second Draft Meeting July 8-10, DoubleTree Hotel, Portland, ME Item No. Subject Call to Order Introduction of Members and Guests Approval of First Draft Meeting Minutes (August 2012) [Enclosure] Approval of Second Draft Meeting Agenda Review Meeting Procedures and Revision Schedule Comments/Questions from Committee Members and/or Guests Task Group Reports (if any) Processing of Public/Committee Comments 37 Public Comments 1 Correlating Committee Note Old Business New Business Adjournment

2 NFPA 79 (A2014) Technical Committee on Electrical Standard for Industrial Machinery First Draft Meeting Minutes August Denver, CO Minutes Item , Call to Order The meeting of the Technical Committee on Electrical Standard for Industrial Machinery was called to order by the Chair, Mark Hilbert at 8:00 AM on Monday, August 13, 2012 at the Double Tree by Hilton Hotel Denver located at 3203 Quebec Street Denver, Colorado. Item , Introduction of Members and Guests In addition to the Chair, the following Technical Committee members were present: See the attached attendance sheet. Guests in attendance during all, or part, of the meeting: See the attached attendance sheet. The Chair opened the meeting with welcoming remarks. Self-introductions of meeting attendees and guests were conducted. Item , Approval of ROC Meeting Minutes It was moved, seconded, and voted unanimously affirmative that the minutes of the ROC Meeting held at the Double Tree Milwaukee City Center, Milwaukee WI be approved, as submitted. Item , Approval of Meeting Agenda It was moved, seconded, and voted unanimously affirmative that the agenda of the First Draft Meeting, which is to take action on public inputs submitted for the Fall 2015 revision cycle of NFPA 79, be approved. Item , Selection of New Secretary Chairman Mark Hilbert announced to the committee members that, after more than 30 years as secretary, John Bloodgood has retired, leaving the secretary position vacant. Seeing no volunteers Jim Maxfield volunteered to take minutes for the First Draft Meeting until a new secretary is selected.

3 Item , Review of meeting Procedures and Revision Schedule Staff liaison, Mark Cloutier, explained meeting procedures, new terminology, permitted actions the committee can take on public inputs, reviewed the new Terra system and reviewed the revision schedule to the committee. Item , Comments/Questions from Committee Members and/or Guests Staff liaison, Mark Cloutier, fielded several questions in connection with agenda item Item , Task Group Reports Task Group chair, presented updates on their task group activities, including the following highlights: 1. Grounding and Bonding Task Group Report 2. Task Group Report from Chapter 7 and Control and Technology Task Group Report 4. Manual of Style Task Group Report Item , Processing of Public Inputs All public inputs and committee revisions were acted on. Item , Old Business None reported Item , New Business The committee voted on potential locations and dates for the second draft meeting. Committee locations voted in order of preference: 1. Portland, ME 2. Seattle, WA 3. Burlington, VT Committee dates voted in order of preference: 1. July 8 thru July 12, June 24 thru June 28, June 17 thru June 21, 2013 Item , Adjournment The Chairman declared the meeting adjourned on Friday August 17, 2012 at 12:45 PM.

4 Correlating Committee Note No. 1-NFPA [ Section No ] Submitter Full Name: [ Not Specified ] [ Not Specified ] Submittal Date: Thu Dec 13 13:57:33 EST 2012 Committee Statement and Meeting Notes Committee The Correlating Committee directs the TC to give further consideration to the voting Statement: comments on FR 35. The Correlating Committee has determined that the scope of NFPA 79 is accurate in NEC has purview over working space clearances up to and including the point of connection of the supply to the electrical equipment of the machine. The Correlating Committee also directs the TC to reconsider PI#94. This action will be considered as a public comment. Ballot Results This item has passed ballot 12 Eligible Voters 0 Not Returned 12 Affirmative All 0 Affirmative with Comments 0 Negative with Comments 0 Abstention Affirmative All,,,,,,,,,,,, submittals.nfpa.org/terraviewweb/viewerpage.jsp 1/1

5 Public Comment No. 45-NFPA [ Section No ] * Duct. An enclosed channel designed expressly for holding and protecting electrical conductors, cables, and busbars. Additional Proposed Changes File Name NFPA79sectA3332.docx Description Approved Cover Sheet The term "Raceway" is defined and is the correct term. Adding information in the proposed annex related to the term "duct" is appropriate. Submitter Full Name: Paul Dobrowsky Innovative Technology Services Submittal Date: Thu May 09 10:08:13 EDT 2013 I, Paul Dobrow sky, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Paul Dobrow sky, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 8-NFPA [ Section No ] Industrial Control Panel. An assembly of two or more components consisting of power circuit components only, such as motor controllers overload relays, fused disconnect switches, and circuit breakers; or control circuit components only, such as pushbuttons, pilot lights, selector switches, timers, switches, and control relays; or a combination of power and control circuit components. These components, with associated wiring and terminals, are mounted on or contained within an enclosure or mounted on a subpanel. The industrial control panel does not include the controlled equipment. [NFPA 70, 2014] This definition needs to show that it is extracted from the NEC, actually in section This is part of the effort to standardize definitions throughout the NFPA system by the GOT committee. Submitter Full Name: Marcelo Hirschler GBH International Affilliation: NFPA GOT Submittal Date: Fri Apr 19 16:06:45 EDT 2013 I, Marcelo Hirschler, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Marcelo Hirschler, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 1/31

6 Public Comment No. 9-NFPA [ Section No ] Overcurrent Protective Device, Branch-Circuit. A device capable of providing protection for service, feeder, and branch circuits and equipment over the full range of overcurrents between its rated current and its interrupting rating. Branch-circuit overcurrent protective Such devices are provided with interrupting ratings appropriate for the intended use but no less than 5000 amperes. [NFPA 70, 2014] The proposed change puts the definition in line with the proposed action by NEC CMP 10 for the 2014 edition of the NEC. This is in section 100 of the NEC. The comment is in line with creating consistency in NFPA definitions, as is recommended by NFPA Standards Council for the GOT committee, Submitter Full Name: Marcelo Hirschler Affilliation: GBH International NFPA GOT Submittal Date: Fri Apr 19 16:09:01 EDT 2013 I, Marcelo Hirschler, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Marcelo Hirschler, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 36-NFPA [ Section No ] A supply circuit disconnecting means shall be provided for the following: (1) Each incoming supply circuit to a machine (2) The supply circuit to a feeder system using collector wires, collector bars, slip-ring assemblies, or flexible cable systems (reeled, festooned) to a machine or a number of machines (3) Each on-board power source (e.g., generators, batteries, uninterruptible power supplies (UPS ) ) Exception: Where an on-board battery or UPS power source supplies only control circuits, other means to denergize its supply output(s) shall be permitted (e.g. control rated switch, EPO input interlock) * Each disconnecting means required by shall be legibly marked to indicate the equipment it disconnects Where a machine is supplied by more than one supply circuit, a marking shall be installed at each supply circuit disconnect location denoting the location of all other supply circuit disconnects. Revised original proposed text to focus on battery and UPS's only. Also added reference to battery as type of onboard power source Related Items from the Public Input Stage for This Document Related Item Public Input No. 71-NFPA [Section No [Excluding any Sub-Sections]] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Fri May 03 12:45:06 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 2/31

7 Public Comment No. 43-NFPA [ Section No ] A supply circuit disconnecting means shall be provided for the following: (1) Each incoming supply circuit to a machine (2) The supply circuit to a feeder system using collector wires, collector bars, slip-ring assemblies, or flexible cable systems (reeled, festooned) to a machine or a number of machines (3) Each on-board power source (e.g., generators, uninterruptible power supplies) Exception: Communication and remote control and signaling circuits of less than 50 volts shall not be required to be provided with a supply circuit disconnecting means * Each disconnecting means required by shall be legibly marked to indicate the equipment it disconnects Where a machine is supplied by more than one supply circuit, a marking shall be installed at each supply circuit disconnect location denoting the location of all other supply circuit disconnects. Additional Proposed Changes File Name NFPA79sect5311.docx Description Approved Cover Sheet Section includes "electronic circuits" in the description. It is not necessary or practical to include a disconnecting means for these limited energy circuits. This comment is submitted based on the committee statement on PI 81. Submitter Full Name: Paul Dobrowsky Submittal Date: Wed May 08 11:38:34 EDT 2013 I, Paul Dobrow sky, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Paul Dobrow sky, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 3/31

8 Public Comment No. 11-NFPA [ Section No ] The supply circuit disconnecting means other than attachment plugs and receptacles shall be mounted within the control enclosure or immediately adjacent thereto. Exception No. 1: Externally mounted supply circuit disconnecting means, whether interlocked or not interlocked with the control enclosure, supplying machines totaling 2 hp or less shall be permitted to be mounted up to 6 m (20 ft) away from the enclosure providing that the disconnecting means is in sight from and readily accessible to the operator. Exception No. 2: A supply circuit disconnecting means mounted in a separate enclosure and interlocked in accordance with with the control enclosure(s) it supplies shall be permitted to be mounted up to 6 m (20 ft) away providing that the disconnecting means is in sight from the control enclosure(s) and readily accessible to the operator. The control enclosure(s) shall be marked indicating the location of the disconnecting means. The disconnecting means shall be marked indicating the industrial machine it supplies. The exception was added at the first draft meeting prior to the relocation of the interlocking requirements from to The proposed change coordinates that action with the new exception. Submitter Full Name: Mark Hilbert MR Hilbert Electrical Inspecti Submittal Date: Wed Apr 24 09:23:01 EDT 2013 I, Mark Hilbert, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed Change and the Statement of Problem and Substantiation). I understand and intend that I acquire no rights, including rights as a joint author, in any publication of the NFPA in w hich this Public Comment in this or another similar or derivative form is used. I hereby w arrant that I am the author of this Public Comment and that I have full pow er and authority to enter into this copyright By checking this box I affirm that I am Mark Hilbert, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and intend that, by checking this box, I am creating an electronic signature that w ill, upon my submission of this form, have the same legal force and effect as a handw ritten signature Public Comment No. 17-NFPA [ Section No ] The supply circuit disconnecting means other than attachment plugs and receptacles shall be mounted within the control enclosure or immediately adjacent thereto. Exception No. 1: Externally mounted supply circuit disconnecting means, whether interlocked or not interlocked with the control enclosure, supplying machines totaling 2 hp or less shall be permitted to be mounted up to 6 m (20 ft) away from the enclosure providing that the disconnecting means is in sight from and readily accessible to the operator. All accessible live parts need to be properly guarded per section 6.2. Exception No. 2: A supply circuit disconnecting means mounted in a separate enclosure and interlocked in accordance with with the control enclosure(s) it supplies shall be permitted to be mounted up to 6 m (20 ft) away providing that the disconnecting means is in sight from the control enclosure(s) and readily accessible to the operator. The control enclosure(s) shall be marked indicating the location of the disconnecting means. The disconnecting means shall be marked indicating the industrial machine it supplies. All accessible live parts need to be properly guarded per section 6.2. It ensures that a person entering enclosure with remote disconnect and has not disconnected the disconnect will not be injured as with a interlocked disconnect. Submitter Full Name: RICHARD TRAINOR TUV SUD AMERICA Submittal Date: Fri Apr 26 15:20:04 EDT 2013 I, RICHARD TRAINOR, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am RICHARD TRAINOR, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 4/31

9 Public Comment No. 24-NFPA [ Sections , ] Sections , The supply Each supply circuit disconnecting means other than attachment plugs and receptacles shall be mounted within the control enclosure or immediately adjacent thereto. Exception No. 1: Externally mounted supply circuit disconnecting means, whether interlocked or not interlocked with the control enclosure, supplying machines totaling 2 hp or less shall be permitted to be mounted up to 6 m (20 ft) away from the enclosure providing that the disconnecting means is in sight from and readily accessible to the operator. Exception No. 2: A supply circuit disconnecting means mounted in a separate enclosure and interlocked in accordance with with the control enclosure(s) it supplies shall be permitted to be mounted up to 6 m (20 ft) away providing that the disconnecting means is in sight from the control enclosure(s) and readily accessible to the operator. The control enclosure(s) shall be marked indicating the location of the disconnecting means. The disconnecting means shall be marked indicating the industrial machine it supplies Each supply circuit disconnecting means mounted within or adjacent to the control enclosure shall be interlocked with the control enclosure in accordance with Where the Where a supply circuit disconnecting means is supplying machines totaling 2 hp or less is not adjacent to the control enclosure, or where the where a supply disconnecting means is an attachment plug and receptacle, the control enclosure shall comply with and a safety sign shall be provided in accordance with Section The proposed revisions provide the correct reference to in the interlocking requirements in 5,3.1.3 exception 2. The additional language in clarifies the intent of that only separately mounted disconnects for small machines totaling 2 hp or less do not need to be interlocked with the control enclosures. The changes from "the" to "a" or "each" and intended as editorial to align and Related Items from the Public Input Stage for This Document Related Item First Revision No. 45-NFPA [Section No ] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Tue Apr 30 23:21:55 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 5/31

10 Public Comment No. 46-NFPA [ Section No. 6.1 ] 6.1* General. Electrical equipment shall provide protection of persons from electric shock, from direct and indirect contact, and warn of potential arc-flash hazards. Reject the change made by the committee during the First Draft. See FR46. Additional Proposed Changes File Name NFPA79sect61.docx Description Approved Cover Sheet This change should not be made. Placing live parts in an enclosure inherently reduces the likelihood of an arc flash event occurring. An indirect contact electric shock incident can occur as a result of an insulation failure if the enclosure integrity or the effective fault current path is compromised. Electrical equipment does not warn of potential arc flash hazards and marking requirements seem to belong in Chapter 16. First Revision No. 47 added Annex material to.6.2 that supports this concept. Submitter Full Name: Paul Dobrowsky Submittal Date: Thu May 09 11:19:50 EDT 2013 I, Paul Dobrow sky, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Paul Dobrow sky, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 19-NFPA [ Section No [Excluding any Sub-Sections] ] When required by and , each disconnecting means mounted within or adjacent to a control enclosure that contains live parts operating at 50 volts ac (rms value) or 60 volts dc or more shall be mechanically or electrically interlocked, or both, with the control enclosure doors so that none of the doors open unless the power is disconnected. Interlocking shall be reactivated automatically when all the doors are closed. Exception No. 1: A disconnecting means used only for maintenance lighting circuits within control enclosures shall not be required to be interlocked with the control enclosure. A safety sign shall be provided that meets the requirements of Exception No. 2: A disconnecting means used for power supply circuits within control enclosures to memory elements and their support logic requiring power at all times to maintain information storage shall not be required to be interlocked with the control enclosure doors. A safety sign shall be provided that meets the requirements of This includes both types of disconnects including exceptions Submitter Full Name: RICHARD TRAINOR TUV SUD AMERICA Submittal Date: Fri Apr 26 15:32:27 EDT 2013 I, RICHARD TRAINOR, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am RICHARD TRAINOR, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 6/31

11 Public Comment No. 25-NFPA [ Section No ] The interlocking means shall meet the following requirements: (1) Utilize a device or tool as specified by the manufacturer of the interlock to allow qualified persons to defeat the interlock (2) Be reactivated automatically when the door(s) is closed (3) Prevent closing of the disconnecting means while the enclosure door is door of the enclosure containing the disconnect is open, unless an interlock is operated by deliberate action With the new permission to allow separately mounted disconnects for machinery in (FR45), the proposed change clarifies that this portion of the interlock requirements is mandated only for the enclosure containing the disconnect itself. Related Items from the Public Input Stage for This Document Related Item First Revision No. 45-NFPA [Section No ] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Tue Apr 30 23:29:13 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 18-NFPA [ Section No ] Where provided with a defeat mechanism as permitted in (1), live parts mounted on the inside of doors (as well as other live parts inside the enclosure) that are operating at over 50 volts shall be protected from unintentional direct contact by the inherent design of components or the application of barriers or obstacles such that a 50 mm (2 in.) sphere cannot contact any of the live parts in question. This section only includes components on a door but excludes other components in the cabinet and it is not tied to section 6.2 clearly. Submitter Full Name: RICHARD TRAINOR TUV SUD AMERICA Submittal Date: Fri Apr 26 15:26:52 EDT 2013 I, RICHARD TRAINOR, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am RICHARD TRAINOR, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 44-NFPA [ Section No ] Rating and Setting of Overcurrent Protective Devices. Motor controllers shall be provided in accordance with Article 430, Part VII of NFPA 70. submittals.nfpa.org/terraviewweb/viewerpage.jsp 7/31

12 * Each motor controller and its associated wiring shall be protected as an individual branch circuit by a short-circuit protective device (SCPD) as specified by the controller manufacturer. The maximum rating of the designated SCPD shall be as shown in Table Table Maximum Rating or Setting of Fuse and Circuit Breakers: Motor, Motor Branch Circuit, and Motor Controller Fuse Class with Non Time Delay Full-Load Current (%) AC-2 AC-3 AC-4 R J CC T Type 2 of Application Fuse Class with Time Delay 1 AC-2 AC-3 AC-4 RK RK J CC Instantaneous trip circuit breaker Inverse trip circuit breaker Note: Where the values determined by Table do not correspond to the standard sizes or ratings, the next higher standard size, rating, or possible setting shall be permitted. 1 Where the rating of a time-delay fuse (other than CC type) specified by the table is not sufficient for the starting of the motor, it shall be permitted to be increased but shall in no case be permitted to exceed 225 percent. The rating of a time-delay Class CC fuse and non time-delay Class CC, J, or T fuse shall be permitted to be increased but shall in no case exceed 400 percent of the full-load current. 2 Types of starting duty are as follows: (a) AC-2: All light-starting duty motors, including slip-ring motors; starting, switching off. (b) AC-3: All medium starting duty motors including squirrel-cage motors; starting, switching off while running, occasional inching, jogging, or plugging but not to exceed 5 operations per minute or 10 operations per 10 minutes and all wye-delta and two-step autotransformer starting motors. (c) AC-4: All heavy starting duty motors including squirrel-cage motors; starting, plugging, inching, jogging. 3 Unless a motor controller is listed for use with RK-5 fuses, Class RK-5 fuses shall be used only with NEMA-rated motor controllers. 4 Instantaneous trip circuit breakers shall be permitted to be used only if they comply with all of the following: (a) They are adjustable. (b) Part of a combination controller has motor-running protection and also short-circuit and ground-fault protection in each conductor. (c) The combination is especially identified for use. (d) It is installed per any instructions included in its listing or labeling. (e) They are limited to single motor applications, circuit breakers with adjustable trip settings shall be set at the controller manufacturer's recommendation, but not greater than 1300 percent of the motor full-load current. 5 Where the rating of an inverse time circuit breaker specified in Table is not sufficient for the starting current of the motor, it shall be permitted to be increased but in no case exceed 400 percent for full-load currents of 100 amperes or less or 300 percent for full-load currents greater than 100 amperes. Exception : Table shall not apply to Design B energy efficient motor circuits. The provisions of NFPA 70, shall be observed for Design B energy efficient motor circuits A listed self-protected combination controller shall be permitted in lieu of the devices specified in Table for branch circuit and overload protection of a single motor circuit Where a listed self-protected combination controller has an adjustable, instantaneous trip setting, the setting shall not exceed 1300 percent of fullload motor current for other than Design B energy efficient motors and not more than 1700 percent of full-load motor current for Design B energy efficient motors Several motors, each not exceeding 1 hp in rating, shall be permitted on a nominal 120-volt branch circuit protected at not over 20 amperes or a 600-volt nominal or less branch circuit, protected at not over 15 amperes, where all of the following conditions are met: (1) The full-load rating of each motor does not exceed 6 amperes. (2) The rating of the branch-circuit short-circuit and ground-fault protective device marked on any of the controllers is not exceeded. The shortcircuit and ground-fault protection is provided by a single inverse time circuit breaker or single set of fuses. (3) Individual overload protection conforms to Section 7.3. submittals.nfpa.org/terraviewweb/viewerpage.jsp 8/31

13 Where the branch-circuit short-circuit and ground-fault protective device is selected not to exceed that allowed by for the smallest rated motor, two or more motors or one or more motors and other load(s), with each motor having individual overload protection, shall be permitted to be connected to a branch circuit where it can be determined that the branch-circuit short-circuit and ground-fault protective device will not open under severe normal conditions of service that might be encountered. The short-circuit and ground-fault protection is provided by a single inverse time circuit breaker or single set of fuses Two or more motors or one or more motor(s) and other load(s), and their control equipment shall be permitted to be connected to a single branch circuit where short-circuit and ground-fault protection is provided by a single inverse time circuit breaker or a single set of fuses, provided the following conditions under (1) and either (2) or (3) are met: (1) Each motor controller and overload device is either listed for group installation with specified maximum branch-circuit protection or selected such that the ampere rating of the motor branch short-circuit and ground-fault protective device does not exceed that permitted by for that individual motor controller or overload device and corresponding motor load. (2) The rating or setting of the branch short-circuit and ground-fault protection device does not exceed the values in Table for the smallest conductor in the circuit. (3) The rating or setting of the branch short-circuit and ground-fault protection does not exceed the value specified in for the highest rated motor connected to the branch circuit plus an amount equal to the sum of the full-load current ratings of all other motors and the ratings of other loads connected to the circuit. Where this calculation results in a rating less than the ampacity of the branch circuit conductors, it shall be permitted to increase the maximum rating of the fuses or circuit breaker to a value not exceeding that permitted by Sections 12.5 and Overcurrent protection for loads other than motor loads shall be in accordance with 7.2.3, 7.2.4, and Where 16 AWG or 18 AWG conductors are used for branch circuit conductors or tap conductors under , the rating and type of the branch short-circuit and ground-fault protection shall be in accordance with Table Relationship Between Conductor Size and Maximum Rating or Setting of Short-Circuit Protective Device for Power Circuits Group Installations Conductor Size Maximum Rating Fuse or Inverse Time* (AWG) Circuit Breaker (amperes) 18 See footnote. 16 See footnote / / /0 800 * Maximum ratings and type of branch short-circuit and ground-fault protective devices for 16 AWG and 18 AWG shall be determined in accordance with For group installations described in (3), the conductors of any tap supplying a single motor shall not be required to have an individual branch-circuit short-circuit and ground-fault protective device, provided they comply with one of the following: (1) No conductor to the motor shall have an ampacity less than that of the branch-circuit conductors. (2) No conductor to the motor shall have an ampacity less than one-third that of the branch-circuit conductors, with a minimum in accordance with Sections 12.5 and 12.6, the conductors to the motor overload device being not more than 7.5 m (25 ft) long and being suitably protected from physical damage in accordance with Chapter 13. (3) Conductors from the branch-circuit short-circuit and ground-fault protective device to a listed manual motor controller additionally marked Suitable for Tap Conductor Protection in Group Installations or to a branch circuit protective device shall be permitted to have an ampacity not less than 1/10 the rating or setting of the branch-circuit short-circuit and ground-fault protective device. The conductors from the controller to the motor shall have an ampacity in accordance with Sections 12.5 and The conductors from the branch-circuit shortcircuit and ground-fault protective device to the controller shall (1) be enclosed either by an enclosed controller or by a raceway and be not more than 3 m (10 ft) long or (2) have an ampacity not less than that of the branch-circuit conductors. Additional Proposed Changes File Name NFPA79sect7210.docx Description Approved Cover Sheet Transformers and overload device requirements are provided with references to the NEC. A similar requirement should be included for motor controllers. submittals.nfpa.org/terraviewweb/viewerpage.jsp 9/31

14 Submitter Full Name: Paul Dobrowsky Innovative Technology Services Submittal Date: Wed May 08 12:24:26 EDT 2013 I, Paul Dobrow sky, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Paul Dobrow sky, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 27-NFPA [ Section No ] Where the branch-circuit short-circuit and ground-fault protective device is selected not to exceed that allowed by for the smallest rated motor, two or more motors or one or more motors and other load(s), with each motor having individual overload protection, shall be permitted to be connected to a branch circuit where it can be determined that the branch-circuit short-circuit and ground-fault protective device will not open under severe normal conditions of service that might be encountered. The short-circuit and ground-fault protection is provided protection shall be provided by a single inverse time circuit breaker or single set of fuses. Replacing "is" with "shall be" aligns with the manual of style for normative text. Related Items from the Public Input Stage for This Document Related Item First Revision No. 16-NFPA [Section No ] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Wed May 01 00:10:37 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 10/31

15 Public Comment No. 47-NFPA [ Section No ] Equipment Protection. Where provided, SPDs shall be connected across the terminals of all equipment requiring such protection. Additional Proposed Changes File Name NFPA79sect783.docx Description Approved Cover Sheet I understand this is an existing requirement but SPD's are installed by choice so why shouldn't the designer or installer be permitted to decide where to connect them. Submitter Full Name: Paul Dobrowsky Submittal Date: Thu May 09 11:21:31 EDT 2013 I, Paul Dobrow sky, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Paul Dobrow sky, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 28-NFPA [ Section No. 8.1 ] 8.1 * General Applicability. This chapter provides the requirements for grounding, bonding, and for the grounded conductor Connections. Grounded conductors shall not be connected to the equipment grounding circuit, except for separately derived systems Mounting. Mounting hardware shall not be used for terminating conductors used for grounding or bonding. As commented in ballot statement for FR-50, the current Annex note should be changed to direct user to Annex J on terminology. Related Items from the Public Input Stage for This Document Related Item First Revision No. 50-NFPA [Global Input] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Wed May 01 00:24:55 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 11/31

16 Public Comment No. 30-NFPA [ Section No ] Conductors used for grounding and bonding purposes shall be copper. Stipulations on stranding and flexing as outlined in Chapter 12 shall apply. Exception : Machine members or structural parts of the electrical equipment shall be permitted to be used in the to connect exposed conductive parts of the machine to the equipment grounding circuit provided that the cross-sectional area of these parts provide the same or better conductivity as the minimum cross-sectional area of the copper conductor required. The cross sectional area shall be in accordance with one or more of the following: (1) Steel 10 times that of copper (2) Iron 6 times that of copper (3) Aluminum 2 times that of copper The new proposed new exception overly broadens the use of machine members and structural parts of the electrical eqiupment to serve as part of the equipment grounding circuit, which as described in consists of equipment grounding terminals, conductors, and bonding jumpers. Not only does this conflict with , the use of these to serve as the equipment grounding conductor is not accepted by international standards. However, given that machines are often made up of numerous exposed conductive parts connected to each other, it is reasonable to assume that they could be used to interconnect machine elements and ensure equipotential bonding and connection to the equipment grounding circuit. The proposed revision narrows the use of machine members for connection of exposed conductive parts of the machine to the equipment grounding circuit (as required in 8.2.1), but not to serve as the primary fault path. Related Items from the Public Input Stage for This Document Related Item First Revision No. 75-NFPA [Section No. 8.2] Submitter Full Name: Jay Tamblingson Rockwell Automation Submittal Date: Wed May 01 00:42:10 EDT 2013 I, Jay Tamblingson, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am Jay Tamblingson, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and Public Comment No. 20-NFPA [ Section No ] Where hazardous or potentially hazardous electrical devices are mounted on conductive doors or covers, an equipment bonding jumper shall be installed. There is no hazard if low voltage components are mounted on a door and enhances the message that a door must be ground for shock protection. Submitter Full Name: RICHARD TRAINOR TUV SUD AMERICA Submittal Date: Fri Apr 26 15:42:33 EDT 2013 I, RICHARD TRAINOR, hereby irrevocably grant and assign to the National Fire Protection Association (NFPA) all and full rights in copyright in this Public Comment (including both the Proposed By checking this box I affirm that I am RICHARD TRAINOR, and I agree to be legally bound by the above and the terms and conditions contained therein. I understand and submittals.nfpa.org/terraviewweb/viewerpage.jsp 12/31

17 Public Comment No. 33-NFPA [ Section No. 9.2 ] 9.2 * Control Functions. Where control circuits perform safety-related functions, they shall meet the safety performance requirements determined by the risk assessment of the machine and be designed in accordance with the applicable functional safety standards Start Functions. Start functions shall operate by energizing the relevant circuit * Stop Functions. Stop functions shall override related start functions. The reset of the stop functions shall not initiate any hazardous conditions. The three categories of stop functions shall be as follows: (1) Category 0 is an uncontrolled stop by immediately removing power to the machine actuators. (2) Category 1 is a controlled stop with power to the machine actuators available to achieve the stop then power is removed when the stop is achieved. (3) Category 2 is a controlled stop with power left available to the machine actuators Operating Modes Each machine shall be permitted to have one or more operating modes (e.g., automatic, manual, normal, and bypass) determined by the type of machine and its application Where a hazardous condition results from mode selection, inadvertent selection shall be prevented from occurring (e.g., key-operated switch, access code). Mode selection by itself shall not initiate machine operation. A separate action by the operator shall be required * Safeguarding means shall remain effective for all operating modes Indication of the selected operating mode shall be provided (e.g., position of mode selector, provision of indicating light, visual display indication) Overriding Safeguards. Where it is necessary to temporarily override one or more safeguards, a mode selection device or means capable of being secured (e.g., locked) in the desired mode shall be provided to prevent automatic operation. The control circuit for the suspension of a safeguard shall have the same safety requirements as the suspended safeguard itself. In addition, one or more of the following measures shall be provided: (1) Initiation of motion by a hold-to-run or other control device. (2) A portable control station (e.g., pendant) with an emergency stop device, and where used, an enabling device. Where a portable station is used, motion shall only be initiated from that station. (3) Limiting the speed or the power of motion. (4) Limiting the range of motion Operation General The necessary interlocks shall be provided for safe operation Measures shall be taken to prevent movement of the machine in an unintended manner after any stopping of the machine (e.g., locked-off condition, power supply fault, battery replacement, lost signal condition with cableless control) Start The start of an operation shall be possible only where all of the safeguards are in place and functional except for conditions as described in On those machines where safeguards cannot be applied for certain operations, manual control of such operations shall be by hold-torun controls together with enabling control, where appropriate Interlocks shall be provided to ensure correct sequential starting On machines requiring the use of more than one control station to initiate a start, the following criteria shall be met: (1) Each control station shall have a separate manually actuated start control device. (2) All required conditions for machine operation shall be met. (3) All start control devices shall be in the released (off) position before a start operation is permitted. (4) All start control devices shall be actuated concurrently Stop * Category 0, Category 1, and/or Category 2 stops shall be provided as determined by the risk assessment and the functional requirements of the machine. Category 0 and Category 1 stops shall be operational regardless of operating modes, and Category 0 shall take priority. submittals.nfpa.org/terraviewweb/viewerpage.jsp 13/31

18 Where required, provisions to connect protective devices and interlocks shall be provided. Where applicable, the stop function shall signal the logic of the control system that such a condition exists * Emergency Operations (Emergency Stop, Emergency Switching Off). Emergency operation requirements are as follows: (1) This section specifies the requirements for the emergency stop and the emergency switching-off functions of the emergency operations, both of which are initiated by a single human action. (2) Once active operation of an emergency stop (see Section 10.7 ) or emergency switching off (see Section 10.8 ) actuator has ceased following a command, the effect of this command shall be sustained until it is reset. This reset shall be possible only at that location where the command has been initiated. The reset of the command shall not restart the machinery but only permit restarting. (3) It shall not be possible to restart the machinery until all emergency stop commands have been reset. It shall not be possible to reenergize the machinery until all emergency switching off commands have been reset Emergency Stop. Emergency stop functions provided in accordance with shall be designed to be initiated by a single human action In addition to the requirements for stop, the emergency stop shall have the following requirements: (1) It shall override all other functions and operations in all modes. (2) Power to the machine actuators, which causes a hazardous condition(s), shall be removed as quickly as possible without creating other hazards (e.g., by the provision of mechanical means of stopping requiring no external power, by reverse current braking for a Category 1 stop). (3) The reset of the command shall not restart the machinery but only permit restarting Where required, provisions to connect additional emergency stop devices shall be provided in accordance with Section The emergency stop shall function as either a Category 0 or a Category 1 stop ( see ). The choice of the category of the emergency stop shall be determined by the risk assessment of the machine * Where a Category 0 or Category 1 stop is used for the emergency stop function, it shall have a circuitry design (including sensors, logic, and actuators) according to the relevant risk as required by Section 4.1 and Final removal of power to the machine actuators shall be ensured and shall be by means of electromechanical components. Where relays are used to accomplish a Category 0 emergency stop function, they shall be nonretentive relays. Exception : Drives, or solid state output devices, designed for safety-related functions shall be allowed to be the final switching element, when designed according to relevant safety standards * Emergency Switching Off. Where the emergency switching-off function is used, it shall be initiated by a single human action Emergency switching off shall be permitted under any of the following conditions: (1) Where protection against direct contact (e.g., with collector wires, collector bars, slip-ring assemblies, control gear in electrical operating areas) is achieved only by placing out of reach or by obstacles (2) Where other hazards or damage caused by electricity are possible Emergency switching off shall be accomplished by disconnecting the incoming supply circuit of the machine effecting a Category 0 stop. Where the machine cannot tolerate the Category 0 stop, it shall be necessary to provide other protection (e.g., against direct contact), so that emergency switching off is not necessary Hold-to-Run Controls * Hold-to-run controls (e.g., jog, inch functions) shall require continuous actuation of the control device(s) to achieve operation Jog or inch functions shall operate only in the manual mode. Manual reverse shall be considered a jog function. The prevention of run or automatic operation during jog or inch shall be accomplished by an operator interface and a separate jog or inch selection method * Two-Hand Controls. submittals.nfpa.org/terraviewweb/viewerpage.jsp 14/31

19 All two-hand controls shall have the following features: (1) The provision of two control devices shall require the concurrent actuation by both hands. (2) It shall be necessary to actuate the control devices within a certain time limit of each other, not exceeding 0.5 second. (3) Where this time limit is exceeded, both control devices shall be released before operation is initiated. (4) The control devices shall require continuous actuation during the hazardous conditions. (5) Machine operation shall cease upon the release of either control device when hazardous conditions are still present. (6) Machine operation shall require the release of both control devices before the machine operation is re-initiated Enabling Control An enabling control function incorporating the use of an enabling device shall, when activated, allow machine operation to be initiated by a separate start control and, when deactivated, stop the machine and prevent initiation of machine operation. An enabling device provided as a part of the enabling control function shall be designed to allow motion when actuated in one position only. In any other position, motion shall be inhibited Enabling controls shall have the following features: (1) Connect to a Category 0 or a Category 1 stop (see ) (2) Design follows ergonomic principles (3) For two-position types, the positions are as follows: (4) Position 1 is the off function of the switch (actuator is not operated). (5) Position 2 is the enabling function (actuator is operated). (6) For three-position types, the positions are as follows: (7) Position 1 is the off function of the switch (actuator is not operated). (8) Position 2 is the enabling function (actuator is operated in its mid position). (9) Position 3 is the off function of the switch (actuator is operated past its mid position). (10) A three-position enabling control shall require manual operation to reach Position 3. When returning from Position 3 to Position 2, the function shall not be enabled An enabling control shall automatically return to its off function when its actuator is not manually held in the enabling position Combined Start and Stop Controls. A single pushbutton and other devices that alternately start and stop motion shall only be used for secondary functions where no hazardous condition arises when they are operated Cableless Control Functions * General. Cableless control (e.g., radio, infrared) techniques for transmitting commands and signals between a machine control system and operator control station(s) shall meet the requirements of through Means shall be provided to verify the memory elements of the operator control station with the machine. submittals.nfpa.org/terraviewweb/viewerpage.jsp 15/31

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO Item No. Subject 13-6-1 Call to Order (8:00 A.M) 13-6-2 Roll Call 13-6-3 Approval

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical on Fluidized Bed Boilers AGENDA Web/Teleconference 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of Members and Guests 3. Approval of Minutes from

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 17 From: Kimberly Shea, Project Administrator

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 2 FROM: Kimberly Shea, Administrator,

More information

NFPA 101 SAF-RES PUBLIC COMMENTS

NFPA 101 SAF-RES PUBLIC COMMENTS Page 134 of 195 Public Comment No. 3-NFPA 101-2013 [ Section No. 28.7.6.1 ] 28.7.6.1 New draperies, curtains, and other similar loosely hanging furnishings and decorations shall be flame resistant as demonstrated

More information

Page 1 of 37 Public Input No. 1-NFPA 30A-2012 [ New Section after 1.1.2 ] 1.1.3 This code shall not apply to aircraft fuel dispensing facilities. NFPA 30A is commonly referenced, in my opinion, incorrectly,

More information

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016 TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES NFPA 610 First Draft Meeting October 17-18, 2016 Westin Kansas City at Crown Center 1 East Pershing Road Kansas City, MO, 64108 Conference Call Access:

More information

ANSI/NETA Standards Update

ANSI/NETA Standards Update Specifications and Standards Activity ANSI/NETA Standards Update NOW AVAILABALE!!!! NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems The NETA Acceptance Testing

More information

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification Public Comment No. 2-NFPA 73-2014 [ Section No. 4.1.3 ] 4.1.3 Unused Openings. 4.1.3.1 Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Page 1 of 13 Public Comment No. 2-NFPA 703-2013 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 2898, Standard

More information

AGENDA First Draft Meeting for the 2016 Edition of NFPA 70B March 12-14, 2014 San Antonio, TX

AGENDA First Draft Meeting for the 2016 Edition of NFPA 70B March 12-14, 2014 San Antonio, TX National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org Technical Committee on Electrical Equipment Maintenance (EEM-AAA) AGENDA

More information

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN) 4 of 326 11/21/2013 1:03 PM First Revision No. 161-NFPA 72-2013 [ Section No. 3.3.11 ] 3.3.11 Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

More information

Why Selective Coordination is Mandatory -- It Fills the Reliability Hole --

Why Selective Coordination is Mandatory -- It Fills the Reliability Hole -- Why Selective Coordination is Mandatory -- It Fills the Reliability Hole -- The NEC has mandatory selective coordination requirements for the following systems. Emergency Systems- Article 700 700.27 Legally

More information

Page 1 of 190 Public Input No. 22-NFPA 55-2013 [ Global Input ] Throughout the document, delete ANSI from ANSI/ASME B31.3. Current Text: (multiple locations) ANSI/ASME B31.3 (found in Subsections: 2.3.2

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical self-closing device

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

Public Input No. 88-NFPA [ New Section after ] Statement of Problem and Substantiation for Public Input

Public Input No. 88-NFPA [ New Section after ] Statement of Problem and Substantiation for Public Input of 201 1/13/2014 12:51 PM Public Input No. 88-NFPA 20-2013 [ New Section after 3.3.38.10 ] Add New Defination 3.3.28.11 Multiple Stage Multiple Port Pump. A single driver pump with multiple impellers operating

More information

National Electrical Code

National Electrical Code National Electrical Code 409.30 Disconnecting Means Disconnecting means that supply motor loads shall comply with Part IX of Article 30. 410.81 Control (A) Disconnection Luminaires (fixtures) or lamp installation

More information

Technical Committee on Fundamentals of Combustion Systems Hazards

Technical Committee on Fundamentals of Combustion Systems Hazards Technical Committee on Fundamentals of Combustion Systems Hazards AGENDA Dec 4-6, 2013 Georgia Power Company Headquarters Banquet Room 241 Ralph McGill Blvd Atlanta, GA 1. Chair s welcome, call to order,

More information

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours www.garyklinka.com Page 1 of 9 Instructions: Fee $15 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms

More information

Committee on NFPA 85

Committee on NFPA 85 Committee on NFPA 85 M E M O R A N D U M TO: FROM: NFPA Technical Committee on Single Burner Boilers Patti Mucci, Technical Assistant II DATE: August 5, 2009 SUBJECT: NFPA ROP Letter Ballot The ROP letter

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

Technical Committee on Multiple Burner Boilers

Technical Committee on Multiple Burner Boilers Technical Committee on Multiple Burner Boilers AGENDA Salt River Project PERA Club 1 Continential Drive Tempe, AZ January 14-15, 2014 1. Chair s welcome, call to order, and opening remarks at 8:00 a.m.

More information

Page 1 of 198 Public Input No. 88-NFPA 20-2013 [ New Section after 3.3.38.10 ] Add New Defination 3.3.28.11 Multiple Stage Multiple Port Pump. A single driver pump with multiple impellers operating in

More information

26 of 128 9/23/2014 9:25 AM

26 of 128 9/23/2014 9:25 AM 26 of 128 9/23/2014 9:25 AM Second Revision No. 105-NFPA 72-2014 [ Global Comment ] Revise the Annex F figures that include a smoke detector symbol (hexagon with a whisp of smoke) so that the new smoke

More information

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100 Significant Changes to the NFPA 70E Standard 2012 Edition Tech Topics: Standards & Codes Note 4, Issue 1 Peter Walsh, PE Sr. Field Engineer Points of Interest: Arc-Rated (AR) vs. Flame-Resistant (FR) Training

More information

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators GPS 140 NEC Requirements for Generators WHAT YOU WILL LEARN NEC requirements for on-site power generation. Recent events have created increased interest in standby power This module organizes NEC requirements

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

Public Comment No. 7-NFPA 30A-2013 [ Section No ] Page 1 of 13 Public Comment No. 7-NFPA 30A-2013 [ Section No. 6.4.2 ] 6.4.2 Additional Proposed Changes Each pump shall have installed on the discharge side a listed leak detection device that will provide

More information

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM 1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,

More information

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -

More information

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry

More information

MEMORANDUM. Technical Committee on Protected Premises Fire Alarm and Signaling Systems

MEMORANDUM. Technical Committee on Protected Premises Fire Alarm and Signaling Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Protected Premises Fire Alarm

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical Committee on Fluidized Bed Boilers AGENDA NFPA Headquarters 1 Batterymarch Park Quincy, MA 02169 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of

More information

TECHNICAL COMMITTEE ON FIRE CODE

TECHNICAL COMMITTEE ON FIRE CODE TECHNICAL COMMITTEE ON FIRE CODE M E M O R A N D U M TO: FROM: Technical Committee on Fire Code (FCC-AAA) Gregory Harrington, P.E., Staff Liaison DATE: February 3, 2011 SUBJECT: NFPA 1124 Amended CP#2

More information

NECA. Standard for Electrical Safety in the Workplace

NECA. Standard for Electrical Safety in the Workplace 4/23/2018 N E R C e- A di st N rib ot ut Fo io r n NECA Significant Changes to the 2018 NFPA 70E Standard for Electrical Safety in the Workplace NFPA 70E Standard for Electrical Safety in the Workplace

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc. Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional

More information

Public Comment No. 13-NFPA [ Section No ]

Public Comment No. 13-NFPA [ Section No ] Public Comment No. 13-NFPA 30-2013 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A 395/A395M, Standard

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Public Comment No. 2-NFPA 16-2013 [ Section No. 3.3.6 ] 3.3.6* Foam-Water Sprinkler System. A piping network connected to a source of foam concentrate and to a water supply. The piping network is equipped

More information

Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related

Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related Introduction One of the proposals to change the 2002 NEC adds a provision

More information

File Name Description Approved. This doc shows the changes to take place in this revision. Changes are marked in comments titled "GLOBAL".

File Name Description Approved. This doc shows the changes to take place in this revision. Changes are marked in comments titled GLOBAL. 1 of 2 3/7/2018, 1:17 PM First Revision No. 8979-NFPA 70-2018 [ Global Input ] Moving and editing language from 706 to 480. See attachment. Sections 706.30, 31, 32, 33, and 34 will be removed entirely.

More information

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete

More information

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016 IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS June 17th, 2016 RE: City Council Adopts 2014 National Electrical Code with Pool Alarm Requirements On April 25th, 2016 the

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 15 FROM: Kimberly Shea DATE:

More information

Control Circuits in acc. with UL508A

Control Circuits in acc. with UL508A Control Circuits in acc. with UL508A UL guideline, chapter 4.3 Definition of Control Circuits Disconnecting Means Protection of Control Circuits Dimensioning of the wires and cables Loads in the Control

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 326 11/21/2013 1:03 PM First Revision No. 158-NFPA 72-2013 [ Global Input ] Revise 2.3.1 to update UL 864 to "2003, revised 2012" and upate ANSI/ASME A17 to 2013. Submittal Date: Wed Sep 11 11:08:52

More information

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement of 1 9/22/2014 1:38 PM Second Revision No. 104-NFPA 72-2014 [ Section No. 3.3.3 ] 3.3.3 Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Board and Care Facilities

More information

NFPA Edition Review

NFPA Edition Review This is a photographic template your photograph should fit precisely within this rectangle. NFPA 70 & 99 How Recent Code Changes Effect Healthcare Facilities Sam C. Terry, P.E. Application Engineer Eaton

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF SECOND DRAFT REPORT Document: NFPA 221 Revision Cycle: A2014 Meeting Date: 5/20/2013

More information

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Supervising Station

More information

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 4-NFPA 111-2016 [ Section No. 1.1.4.1 ] 1.1.4.1 * This standard shall not cover the following: (1) Application of the SEPSS (2) Distribution wiring (3) Systems having total outputs less

More information

Circulation Report for SIG-TMS Comments Document # 72

Circulation Report for SIG-TMS Comments Document # 72 1 72-12 Eligible To Vote:28 Affirmative: 24 : 0 Abstain: 0 : 4 3.3.x Deficiency (New) (Log # 209 ) 72-13 Eligible To Vote:28 Affirmative: 24 : 0 Abstain: 0 : 4 3.3.x Deficiency (New) (Log # 234 ) 72-15

More information

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Wood and Cellulosic

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

Guide Specification Model CTG Automatic Transfer Switch

Guide Specification Model CTG Automatic Transfer Switch Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production

More information

Alberta Municipal Affairs

Alberta Municipal Affairs Alberta Municipal Affairs Upcoming Already Approved by Unanimous Vote Not Required to be Considered in Charlottetown in June Clarence C. Cormier, P.Eng. Chief Electrical Inspector Bob Hall, SCO Electrical

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 14 From: Kimberly Shea, Project Administrator

More information

Overview of Significant 2017 NEC Changes

Overview of Significant 2017 NEC Changes Overview of Significant 2017 NEC Changes National Fire Protection Association. All rights reserved. Five New NEC Articles Article 426 Fixed Resistance and Electrode Industrial Heating Equipment Article

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

Technical Committee on Electrical Equipment Evaluation. ROC Meeting Agenda September 28-29, 2010 Providence, RI

Technical Committee on Electrical Equipment Evaluation. ROC Meeting Agenda September 28-29, 2010 Providence, RI Technical Committee on Electrical Equipment Evaluation ROC Meeting Agenda September 28-29, 2010 Providence, RI Item 10-09-1 Call to Order Item 10-09-2 Introductions Item 10-09-3 Staff Remarks Item 10-09-4

More information

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

WORKING DRAFT OF COMMITTEE MEETING OUTPUT WORKING DRAFT OF COMMITTEE MEETING OUTPUT CONTENT NOT FINAL SUBJECT TO REVISION PRIOR TO LETTER BALLOT AND PUBLICATION OF FIRST DRAFT REPORT Document: NFPA 110 (EPS-AAA) Revision Cycle: A2018 Meeting Date(s):

More information

NFPA Technical Committee on Fire Tests

NFPA Technical Committee on Fire Tests National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Tests Tracy

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 09 FROM: Kimberly Shea DATE:

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

TECHNICAL COMMITTEE ON FIRE PUMPS

TECHNICAL COMMITTEE ON FIRE PUMPS TECHNICAL COMMITTEE ON FIRE PUMPS MEMORANDUM TO: FROM: Technical Committee on Fire Pumps Joanne Goyette, on behalf of C. Duffy / R. P. Benedetti DATE: May 2, 2011 SUBJECT: Letter Ballot on Proposals to

More information

Changes for the New Edition. Senior Engineer, NFPA NFPA

Changes for the New Edition. Senior Engineer, NFPA NFPA Changes for the New Edition Denise Beach Senior Engineer, NFPA NFPA Overview NFPA 58-2014 Substantive Changes TIAs 2017 Edition NFPA 58-2014 Substantive Changes Bulk and Industrial Plants 3.3.10 Bulk Plant.

More information

Correlating Committee on Automatic Sprinkler Systems

Correlating Committee on Automatic Sprinkler Systems Correlating Committee on Automatic Sprinkler Systems M E M O R A N D U M DATE: May 14, 2014 TO: FROM: Principal and Alternate Members of the Correlating Committee on Automatic Sprinkler Systems Matt Klaus,

More information

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

M EM O RA N D UM. NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018) M EM O RA N D UM TO: FROM: DATE: SUBJECT: Correlating Committee on Combustible Dusts Yiu Lee, Project Administrator January 27, 2017 NFPA 652 First Draft Correlating Committee FINAL Ballot Results (A2018)

More information

Agenda Technical Committee on Protected Premises Fire Alarm Systems September 9-11, 2013 Saint Louis, MO

Agenda Technical Committee on Protected Premises Fire Alarm Systems September 9-11, 2013 Saint Louis, MO Agenda Technical Committee on Protected Premises Fire Alarm Systems September 9-11, 2013 Saint Louis, MO Item No. Subject 13-9-1 Call to Order (8:00 A.M) 13-9-2 Roll Call 13-9-3 Approval of Agenda 13-9-4

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 12 FROM: Kimberly Shea DATE:

More information

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations... Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6

More information

MEMORANDUM. Technical Committee on Fundamentals of Fire Alarm and Signaling Systems

MEMORANDUM. Technical Committee on Fundamentals of Fire Alarm and Signaling Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Fundamentals of Fire Alarm

More information

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Testing and Maintenance

More information

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Code (FCC-AAA) Gregory

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency

More information

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC Changes to NFPA 70E - The Role of PdM &Safe PdM Work Practices Tim Rohrer Exiscan LLC Tim@Exiscan.com 585-705-7775 Joe Gierlach ABM Joseph.Gierlach@ABM.com 412-394-4678 Preview Electrical Safety Risk Management

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: NEC Code-Making Panel 3 From: Kimberly Shea, Project Administrator

More information

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS

MEMORANDUM. SUBJ: NFPA 72 Proposed TIA No FINAL CC BALLOT RESULTS National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: NFPA Correlating Committee on Signaling Systems for

More information

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Page 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification

Page 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification First Correlating Revision No. 3-NFPA 101-2016 [ Section No. 6.1.8.1.1 ] 6.1.8.1.1* Definition One- and Two-Family Dwelling Unit. A building that contains not more than two dwelling units, with independent

More information

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.

More information