XLTH Series: Extra Low Temperature Heating Down to -15 F

Size: px
Start display at page:

Download "XLTH Series: Extra Low Temperature Heating Down to -15 F"

Transcription

1 XLTH Series: Extra Low Temperature Heating Down to -15 F Wa Mount Systems 9RLS3H, 12RLS3H, 15RLS3H 18RLXFWH, 24RLXFWH, 30RLXEH Foor Mount Systems 9RLFFH, 12RLFFH, 15RLFFH Muti-Zone Systems AOU18RLXFZH, AOU24RLXFZH, AOU3RLXFZH

2 Not a heating systems are created equa. Without the right technoogy, a system won t work when its needed most. Protection from the Winter s Codest Temperatures When the temperature drops you don t want to be eft in the cod. It s important to choose a heat pump system rated for the cimate you ive in. If your system doesn t operate in severe conditions you and your famiy coud be eft without any heat at a. Fujitsu s ine of mini-spit heat pumps come in different sizes, styes, and rated outdoor temperatures. The Extra Low Temperature Heating ( ) Series features outdoor condensing units engineered to operate in temperatures down to -15 F, ower than any other mini-spit avaiabe today. 2 Shown is an outdoor condensing unit used in a cimate coder than it was rated for. Without the right technoogy, condensate freezes to the bottom of the unit and reduces its efficiency and heating output.

3 Extra Low Temperature Heating Down to -15 F Ambient Heating Temperature of -15 F Other modes may go as ow as -5 F, however they do not incude a base heater and other advancements found in XLTH modes. Meta Fan Guard Whie other modes have a pastic fan guard, XLTH modes use meta, which is most capabe of withstanding the coder eements. Base Heater When temperatures reach 3 F, a buit-in heater warms the base of the outdoor unit so that condensation doesn t freeze. Without a heater, freezing condensate can cause noise, damage to the fan bade, condenser, and system performance. The base of Fujitsu s XLTH outdoor condensing units. Base Drainage Hoes The cutivated base design discharges meted water through many hoes ocated at the bottom of the unit. Improved Heating Capacity Heating capacity at ow outdoor temperatures was improved by adopting a arge heat exchanger and a high capacity compressor. Have Peace of Mind with Fujitsu s XLTH s Fujitsu XLTH Mode Without Base Heater % of Heating Capacity RLXFZ (Standard Muti-Zone) H Series Modes Ambient Temperature (F ) Drain Hoe Base Drain hoe is not fied, no freezing of base Freezing where there is no heater Condition: temp. of 8 FDB / outdoor temp. of 5 FDB, Heating mode, High airfow voume. Operation for 24 hours.

4 Wa Mounted High-SEER 9, 12 and 15,000 BTU Systems Systems 9RLS3H, 12RLS3H, 15RLS3H Up to 33.0 SEER Modes ASU9RLS3 ASU12RLS3 ASU15RLS3 Modes AOU9RLS3H AOU12RLS3H AOU15RLS3H Energy Efficient 9RLS3H 12RLS3H 15RLS3H SEER EER HSPF Among the Word s Most Efficient s Systems feature high efficiencies and are ENERGY STAR Quaified, meaning ower utiity bis for home and business owners. Power Diffuser A power diffuser operates automaticay in either heating or cooing mode to optimay contro the airfow. A comfortabe space is quicky achieved. Cooing During cooing mode, far reaching horizonta airfow quicky creates a comfortabe space throughout the entire room. Heating During heating mode, vertica airfow provides comfortabe foor eve heating. Energy Saving Program ESP knows how to save you money even when you forget. If you eave the room without turning the unit off, ESP knows that you eft and 20 minutes ater, set temperature is increased by 4 F when cooing and reduced by 8 F when heating. When you come back to the room, it returns to previous operating mode. This prevents wastefu operation to save energy without you having to think about it. Set Temp. Set Temp. Cooing/Dry Heating Norma Operation Judgment (20 min.) Judgment (20 min.) SAVE! Saving Operation AUTO RESTART +4 F *Max. 8 F -8 F *Max. 0 F Norma Operation 4

5 Extra Low Temperature Heating Down to -15 F Standard Features ESP I/O 3 Party Dry Auto Mode 50 F Dry Mode Auto Louver: 4-Way 3rd Party Device Contro+ Low Ambient Cod Powerfu Operation Mode Minimum Heat (50 F/10 C) Auto Restart/Reset Auto Changeover Low Ambient Cooing 3 Cod Prevention Temp. Sensor* Remote Sensor Designer wireess remote contro * Avaiabe ony with optiona wired remote controer and optiona interface kit. + Avaiabe ony with optiona interface kit. Operation monitoring and On/Off contro ony. Optiona Accessories Wired Remote Controer: UTY-RVNUM Backit and incudes room temperature Wired Remote Controer: UTY-RNNUM Simpe Remote Controer: UTY-RSNUM Counication Kit: UTY-TWBXF1 Dry Contact Wire Kit: UTY-XWZXZ5 Quiet 224 (380) 224 (380) Cg 259 (440) Htg 294 (500) Noise Leve db(a) Cg/Htg: Hi Medium Low Quiet Noise Leve db(a) Cg/Htg Current Rated/Max (A): Cooing Heating Power Use Rated/Max (kw): Cooing Heating Fan Speeds Stage Air Direction: Horizonta Vertica Air Fiter Connection Method Combined Min. Lgth Ft (m) 42/41 3/35 32/31 23/23 42/4 2.5/ / / /1.93 Washabe Fare 10 (3) (20) 42/41 3/35 32/31 23/23 43/4 3.8/9.4 4./ / /1.94 Washabe Fare 10 (3) (20) 45/45 40/39 34/33 2/2 49/50 4.8/ / / /2.19 Washabe Fare 10 (3) (20) Combined Max. Lgth Ft (m) Dimensions Inches () ASU9RLS3, ASU12RLS3, ASU15RLS3 10-5/8 (20) 11-5/8 (295) 3 (940) Max. Vertica Diff. Ft (m) Conn. Pipe Diameter Inch Net Weight bs. (kg) Dimensions: Height Inch 49 (15) 49 (15) 49 (15) Suc.3/8 Dis.1/4 Suc.1/2 Dis.1/4 31 (14) 8 (39) 31 (14) 8 (39) 31 (14) 88 (40) 11-5/8 24-/1 11-5/8 24-/1 11-5/ Width Inch / / /8 Depth Inch AOU9RLS3H, AOU12RLS3H, AOU15RLS3H 3/4 (20) 31-1/8 (90) 2-9/1 (5) 11-11/32 (290) (pre-charge: 49 ) (pre-charge: 49 ) (pre-charge: 49 ) Suc.3/8 Dis.1/4 Refrigerant 24-/ /8 11-/1 10-5/8 11-/1 10-5/8 11-/ Note: Figures are based on 230 Vots. 3/4 (20) 24-/1 (20) 9,000 12,000 14,500 Nomina Cooing BTU/h Min.~Max. Cooing BTU/h 3,100~12,000 3,100~13,00 3,100~18,400 12,000 1,000 18,000 Nomina Heating BTU/h Min.~Max. Heating BTU/h 3,100~22,000 3,100~22,100 3,100~23,900 HSPF BTU/hW SEER BTU/hW EER Cg/Htg Cg. Operating Range F( C) 14~115 (-10~4) 14~115 (-10~4) 14~115 (-10~4) Htg. Operating Range F( C) -15~5 (-2~24) -15~5 (-2~24) -15~5 (-2~24) 2. (1.2) 2. (1.3) 4.0 (1.9) Moisture Remova Pt./h(/h) Votage/Frequency/Phase /0/ /0/ /0/1 MAX.CRT.BKR (A) Air Circ. C.F.M. (m /h): Hi 489 (830) 489 (830) 489 (830) Medium 400 (80) 400 (80) 459 (80) Low 341 (580) 341 (580) 31 (30) AOU15RLS3H ASU15RLS3 rd Energy Saving Program Quiet Mode () Low Noise Mode AOU12RLS3H Seep Timer 24 Hour Timer Weeky Timer ASU12RLS3 24 Hour Economy Mode Appe Catechin Fiter Ion Deodorizing Fiter 9RLS3H 12RLS3H 15RLS3H Wireess Remote Contro AOU9RLS3H Wireess ASU9RLS3 13-/8 (352) 5

6 Wa Mounted 18, 24 and 30,000 BTU Systems Systems 18RLXFWH, 24RLXFWH, 30RLXEH Up to 20.0 SEER, 12.3 HSPF Modes ASU18RLF ASU24RLF Modes AOU18RLXFWH AOU24RLXFWH Modes ASU30RLE Modes AOU30RLXEH Styish, sim and eegant, these wa mounted ductess heat pumps are designed for singe rooms. These systems feature ong piping engths and ow ambient heating and cooing, making them great for soving various appication-specific probems. With more efficient zone contro, ductess mini-spits are perfect for renovations, restorations, conversions, and add-ons. Optiona Accessories Controers Wired Remote^ UTY-RVNUM Backit and incudes room temperature Wired Remote (Touch Pane) UTY-RNRUZ1*^ Backit and incudes room temperature Extended Line Set Long piping engths between indoor and outdoor units provides fexibiity and increased appications. Max Pipe Length Systems 18/24RLXFWH 15 ft. (50m) System 30RLXWEH 24 ft. (5m) Max Height Diff. 98 ft. (30m) Interface Kits Wired Remote^ UTY-RNNUM *Compatibe with System 30RLXEH ony. Simpe Remote^ UTY-RSNUM Dry Contact Wire Kit UTY-XWZX Interface Kit UTY-XCSXZ1* Interface Kit Box UTY-GXXB* Unit Input/Output Connector UTY-XWZXZ3* Energy Efficient A systems feature high efficiencies and are ENERGY STAR Quaified, meaning ower utiity bis for home and business owners. 18RLXFWH 24RLXFWH 30RLXEH SEER EER HSPF Lock Out Function This feature is set by the contractor on behaf of the Coercia Property Owner to prevent either Cooing or Heating operation from occurring. This is not a function that can be set by a tenant, user, or home owner. Lead Lag Contro^ for System 30RLXEH Aternate operation of systems Back up operation of redundant system Dua stage operation ^ Wired remotes cannot be used when using this feature. This incudes UTY-RNRUZ1, UTY-RVNUM, UTY-RNNUM, UTY-RSNUM.

7 Extra Low Temperature Heating Down to -15 F Standard Features Wireess 18RLXFWH 24RLXFWH 30RLXEH Wireess Remote Contro Quiet Mode () Appe Catechin Fiter Ion Deodorizing Fiter Low Noise Mode* Diffuser Power Diffuser Auto Restart/Reset 18,000 22,000 30,000 Nomina Cooing BTU/h Min.~Max. Cooing BTU/h,000~23,000 9,900~2,300 9,900~32,400 Auto Changeover 21,00 25,200 32,000 Nomina Heating BTU/h,000~29,000,500~3,200 8,000~3,500 Min.~Max. Heating BTU/h Dry Mode Low Ambient Cooing D HSPF BTU/hW Auto Louver: 4-Way Bue Fin Heat Exchanger B F SEER BTU/hW 15 ft Auto Mode EER Cg Long Piping Length P Cg. Operating Range F( C) -5~115 (-20~4) -5~115 (-20~4) -5~115 (-20~4) Base Pan Heater Powerfu Operation Mode* H Htg. Operating Range F( C) -15~5 (-2~24) -15~5 (-2~24) -15~5 (-2~24) 50 F I/O Minimum Heat (50 F/10 C) Third Party Device Contro 3 P 5.9 (2.8).3 (3.0) 9. (4.) Moisture Remova Pt./h(/h) Votage/Frequency/Phase /0/ /0/ /0/1 Economy Mode Cod Prevention C MAX.CRT.BKR (A) Energy Saving Program* Pump Down Operation* ESP 59 (1,120) / 812 (1,380) Air Circ. C.F.M. Cg/Htg (m /h): Hi 541 (920) *Appies to System 30RLXEH ony. (1,150) 530 (900) 5 (1,130) Medium 435 (40) Low 35 (20) 435 (40) 53 (910) 30 (520) / Quiet 418 (10) 35 (20) 318 (540) Noise Leve db(a) Cg/Htg: Hi 43/44 49/49 50/49 ASU18RLF, ASU24RLF Medium 3/3 42/42 45/44 Low 33/33 3/3 38/38 28/28 33/33 32/32 Quiet 4/50 54/55 53/54 Noise Leve db(a) Cg/Htg Current Rated (A): Cooing Heating 39-1/4 (998) 9 (228) Power Use Rated/Max (kw): Cooing 1.35/ / /3.83 Heating 1.5/ / /4.28 ASU30RLE 11 (280) Fan Speeds Stage 45-1/4 (1,150) Air Direction: Horizonta Vertica Air Fiter Washabe Washabe Washabe Connection Method Fare Fare Fare Combined Min. Lgth Ft (m) 1 (5) 1 (5) 1 (5) 14 (50) 24 (5) Combined Max. Lgth Ft (m) 14 (50) Seep Timer Weeky Timer Low ry Ambient ue in iping eater rd arty od Pump Down /8 (340) 12-5/8 (320) Dimensions AOU18RLXFWH, AOU24RLXFWH (pre-charge: 5 ) (pre-charge: 5 ) (pre-charge: 5 ) Width Inch 13/1 Depth Inch 3/ / /8 35-1/2 98 (30) Suc.3/8 Dis.5/8 31 (14) 135 (1) 31 (14) 135 (1) 40 (18) 205 (93) 12-5/8 1/2 32-3/4 12-5/8 32-3/4 13-3/ / , /4 35-3/8 39-1/4 35-3/8 45-1/4 35-3/ , ASU18RLF AOU30RLXEH Refrigerant (30) Suc.3/8 Dis.5/8 AOU30RLXEH 32-3/4 98 (30) Suc.3/8 Dis.5/8 ASU30RLE Max. Vertica Diff. Ft (m) Conn. Pipe Diameter Inch Net Weight bs. (kg) Dimensions: Height Inch AOU24RLXFWH 1/2 ASU24RLF 11-13/1 AOU18RLXFWH 1-/ /8 35-1/2 Note: Figures are based on 230 Vots. 3/8 /8 15-3/4

8 Foor Mounted 9, 12, 15,000 BTU Systems Systems 9RLFFH, 12RLFFH, 15RLFFH Modes AGU9RLF AGU12RLF AGU15RLF Modes AOU9RLFFH AOU12RLFFH AOU15RLFFH Foor mount systems are idea for residentia radiator repacements or any room with imited upper wa space, ike a kitchen or sunroom. Compact size Avaiabe in 9, 12, or 15,000 BTU singe zone modes Heat pumps provide both cooing and heating Feature twin airfow for improved heat deivery Designer remote contro At ess than 24 high and 30 wide, foor mount modes fit easiy under a standard window and can repace a radiator twice its size whie producing more capacity. Features 2-Fan and Wide Airfow Having both upper and ower airfow quicky warms or coos the entire room. Foor mount can be set in Upward Airfow Ony when occupants wish not to have feet warmed or cooed. Fexibe and Easy Instaation Beneath Standard standard window concave portion 23-5/8 29-1/8 Wa 2-9/1 -/8 2-9/1 3 Haf conceaed* Energy Efficient A systems feature high efficiencies and are ENERGY STAR Quaified, meaning ower utiity bis for home and business owners. Up to 2.0 SEER 5-/8 23-1/4 28-3/4 3-1/8 *Fied suppied insuation required 9RLFFH 12RLFFH 15RLFFH SEER EER HSPF

9 Extra Low Temperature Heating Down to -15 F Standard Features 9RLFFH 12RLFFH 15RLFFH Wireess Remote Contro Appe Catechin Fiter Ion Deoderizing Fiter Seep Timer 24-Hour Timer Auto Louver: Up/Down Auto Mode Minimum Heat Mode Economy Mode Auto Restart/Reset Auto Changeover Powerfu Mode Quiet Mode () 9,000 12,000 Wireess 24 Hour 50 F Dry Mode Cod Prevention C Remote Temp. Sensor od Optiona Accessories Wired Remote Controer: UTY-RVNUM Backit and incudes room temperature 18,000 3,100~20, / ~115 (-10~4) 14~115 (-10~4) 14~115 (-10~4) -15~5 (-2~24) -15~5 (-2~24) -15~5 (-2~24) 2.5 (1.3) 3.8 (1.8) 4.44 (2.1) /0/ /0/ /0/ (50) 335 (50) 383 (50) 21 (40) 21 (40) 30 (520) 212 (30) 212 (30) 235 (400) 159 (20) 159 (20) 159 (20) 40/40 40/40 44/43 35/35 35/35 38/3 29/29 29/29 31/29 23/23 23/23 23/23 50/50 52/52 54/ Manua Manua Manua Auto Auto Auto Washabe Washabe Washabe Yes Yes Yes Yes Yes Yes Fare Fare Fare 10 (3) 10 (3) 10 (3) (20) (20) (20) Combined Max. Lgth Ft (m) (pre-charge: 49 ) (pre-charge: 49 ) 3 Dry Sensor / ,200 3,100~1,00 Wired Remote Controer: UTY-RNNUM Simpe Remote Controer: UTY-RSNUM Dry Contact Wire Kit: UTY-XWZXZ5 Dimensions AGU9RLF, AGU12RLF, AGU15RLF -/8 (200) 23-5/8 (00) (pre-charge: 49 ) Max. Vertica Diff. Ft (m) 49 (15) 49 (15) 49 (15) Conn. Pipe Diameter Inch Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4 Suc. 1/2 Dis. 1/4 Net Weight bs. (kg) 31 (14) 8 (39) 31 (14) 8 (39) 31 (14) 88 (40) Dimensions: Height Inch 23-5/8 24-/1 23-5/8 24-/1 23-5/8 24-/ Width Inch 29-1/8 31-1/8 29-1/8 31-1/8 29-1/8 31-1/8 Depth Inch Front view Side view Refrigerant AOU9RLFFH, AOU12RLFFH, AOU15RLFFH 31-1/8 ( 90 ) 2-9/1(5) 11/1(23) 11-/1(290) /8(23) 24-/1 ( 20 ) 13/1(20) 13/1(20) /8 11-/ /8 11-/ /8 11-/ AOU15RLFFH 29-1/8 (40) AGU15RLF Designer wireess remote contro /13. AOU12RLFFH AGU12RLF 3,100~13,000 3,100~14,300 12,000 1,000 3,100~18,800 3,100~19,500 AOU9RLFFH Nomina Cooing BTU/h Min.~Max. Cooing BTU/h Nomina Heating BTU/h Min.~Max. Heating BTU/h HSPF BTU/hW SEER BTU/hW EER Cg/Htg Cg. Operating Range F( C) Htg. Operating Range F( C) Moisture Remova Pt./h(/h) Votage/Frequency/Phase Recoended Fuse Size (A) Air Circ. C.F.M. (m /h): Hi Medium Low Quiet Noise Leve db(a)cg/htg: Hi Medium Low Quiet Noise Leve db(a) Cg/Htg Current Rated (A): Cooing Heating Power Use Rated (kw): Cooing Heating Fan Speeds Stage Air Direction: Horizonta Vertica Air Fiter Appe Catechin Fiter Ion Deoderizing Fiter Connection Method Combined Min. Lgth Ft (m) AGU9RLF 3/8(9) Note: Figures are based on 230 Vots. 13-/8(352) Front view Side view 9

10 Muti-Zone 18, 24, 3,000 BTU Systems Modes AOU18RLXFZH, AOU24RLXFZH, AOU3RLXFZH Connect 2 to 4 indoor units, depending on mode Modes Modes AOU18RLXFZH AOU24RLXFZH AOU3RLXFZH Wa Mounts ASURLF1 ASU9RLF1 ASU12RLF1 ASU18RLF Foor Mounts AGU9RLF AGU12RLF AGU15RLF Sim Ducts ARURLF ARU9RLF ARU12RLF ARU18RLF Compact Cassettes AUURLF AUU9RLF AUU12RLF AUU18RLF Individua Zoning Contro Why pay to heat or coo areas that no one is occupying? Hacyon systems can have as many as eight indoor air handers (covering eight zones or areas) connected to one outdoor unit. Since each of the zones wi have its own thermostat, you ony heat or coo the areas you want, and not the areas that are unoccupied. Mode Compatibiity AOU18RLXFZH AOU24RLXFZH AOU3RLXFZH kbtu/h Wa Mount (ASU) Foor Mount (AGU) Sim Duct (ARU) Compact Cassette (AUU) Cassette Unit Sim Duct Wa Mount Nomina Capacities, SEER and HSPF Ratings Data beow is based on AHRI 210/240 non-ducted wa mounted modes. Mode AOU18RLXFZH AOU24RLXFZH AOU3RLXFZH Cooing Heating Rated Heating Maximum Unit Capacity Capacity Capacity COP EER SEER Btu/h Btu/h Btu/h HSPF Type Combination 95 F 4 F 1 F 1 F 5 F 4 F Non-Ducted , ,000 14,200 23,00 22, Ducted , ,000 14,200 23,00 22, Mixed , ,000 14,200 23,00 22, Non-Ducted , ,000 15,400 2,400 25, Ducted , ,000 15,400 2,400 25, Mixed , ,000 15,400 2,400 25, Non-Ducted , ,400 21,400 39,300 3, Ducted , ,400 21,400 39,300 3, Mixed , ,400 21,400 39,300 3, Yeow rows represent modes that are ENERGY STAR quaified.

11 Extra Low Temperature Heating Down to -15 F Dimensions AOU18RLXFZH, AOU24RLXFZH 35-/1 (900) 1-9/1 (40) AOU 18RLXFZH AOU 24RLXFZH AOU 3RLXFZH 32-11/1 (830) 13/1 (21) 1-1/4 (31) AOU3RLXFZH Front View 13 (330) 15-3/4 (400) Side View 1/2 (12) Connectabe Unit Number Connectabe Unit Capacity Cass BTU/h Rated Capacity Cooing/Heating BTU/h Cg. Operating Range F( C) Htg. Operating Range F( C) Input Power: Cg/Htg Rated kw* Votage/Frequency/Phase Current: Tota Max. (A) Minimum Circuit Ampacity (A) MAX.CRT.BKR (A) Fan: Type x Quantity Sound Pressure Leve Cooing db(a) Sound Pressure Leve Heating db(a) Pre-Charge Length Tota Ft (m) Max. Length Tota Ft (m) Max. Length Each Ft (m) Min. Length Tota Ft (m) Min. Length Each Ft (m) 2 2 to 3 2 to 4 14,000 to 21,000 14,000 to 2,000 2,000 to 39,000 18,000/22,000 22,000/25,000 35,200/3, to 115 (-10 to 4) -15 to 5 (-2 to 24) 14 to 115 (-10 to 4) -15 to 5 (-2 to 24) 14 to 115 (-10 to 4) -15 to 5 (-2 to 24) 1.33/ / / /0/ /0/ /0/ Propeer x 1 Propeer x 1 Propeer x (30) 98 (30) 14 (50) 14 (50) 230 (0) 230 (0) 82 (25) 82 (25) 82 (25) 49 (15) 49 (15) 49 (15) 1 (5) 1 (5) 1 (5) 38-3/1 (90) 3-3/4 (95) Max. Pipe Height Difference Between Unit & Farthest Ft (m) Max. Pipe Height Difference Between Units Ft (m) Connection Method 49 (15) 49 (15) 49 (15) 33 (10) 33 (10) 33 (10) Fare Fare Fare Conn. Pipe Diameter Inch Liq. 1/4 x 2 Suc. 3/8 x 2 Liq. 1/4 x 3 Suc. 1/2 x 1, 3/8 x 2 Liq. 1/4 x 4 Suc. 1/2 x 1, 3/8 x 3 13/1 (21) 1-5/1 (33) 11/32 (9) Front View 14-9/1 (30) 9/1 (14) Net Weight bs. (kg) Dimensions: Height Inch Width Inch 134 (1) 14 () 205 (93) 32-11/ /1 39-5/ /1 35-/1 38-3/ Depth Inch / Refrigerant 39-5/1 (998) 1-5/1 (440) Side View 11

12 Aowabe Combinations for AOU18RLXFZH, AOU24RLXFZH, AOU3RLXFZH 18, 24, 3,000 BTUs ASURLF1, ASU9RLF1, ASU12RLF1, ASU18RLF, ASU24RLF ARURLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF AUURLF AUU9RLF AUU12RLF AUU18RLF AGU9RLF AGU12RLF AGU15RLF BTU Capacity,000 9,000 12,000 15,000 18,000 24,000 AOU18RLXFZH AOU24RLXFZH AOU3RLXFZH 2 INDOOR UNITS AOU18RLXFZH INDOOR UNITS AOU24RLXFZH INDOOR UNITS AOU3RLXFZH 18*18* INDOOR UNITS AOU3RLXFZH ** * The optiona kit K9FZ1818 (UTP-MU3A2) is necessary for dua zone system **Wa mounted type ASU18RLF can not be connected in this combination. - represents avaiabe circuit for future expansion when connecting this combination. 12

13 Extra Low Temperature Heating Down to -15 F Appications Where can mini-spits be used? Convenience stores Fast food chains Fire houses Poice stations Oi rigs Bars Sunrooms and additions Warehouses Nursing homes Sma offices Oder homes New construction homes Schoos Paces of worship Hospitas and medica faciities Restaurants Computer rooms Hotes and motes Car washes ATM vestibues Just about any pace that requires comfort! 13

14 4 Mode Styes to Choose From Hacyon systems are some of today s most advanced forms of heating and air conditioning, being super quiet, as we as highy energy efficient. With 4 indoor unit styes to choose from, there s a Hacyon system to fit every décor. Wa Mounted They mount high on a wa, out of sight and do not require ductwork, increasing energy efficiency. Quiet operation Easy maintenance High deivered efficiency means ower utiity bis Foor Mounted Foor mount systems are idea for residentia radiator repacements or any room with imited upper wa space, ike a kitchen or sunroom. Compact size fits easiy under a standard window Features twin airfow for improved heat deivery Designer wireess remote contro Compact Cassette Cassettes are extremey discreet, with ony the grie showing in the ceiing. They use the atest fan technoogy to distribute the conditioned air eveny. Wired remote contro (wireess is optiona) Powerfu turbo fan operation Fits into a standard 2 x 2 ceiing grid Avaiabe in XLTH series as Muti-zone ony. Sim Duct Mounted in a ceiing or in a framed encosure beow a ceiing. They use minima ductwork and remain very energy efficient. Conceaed and out of sight Look of centra air with the efficiency of a mini-spit Less ducts = higher efficiency Avaiabe in XLTH series as Muti-zone ony. 14

15 Extra Low Temperature Heating Down to -15 F Optiona Accessories Remote Contros (Compatibe with RLS3H, RLXFWH, RLXEH and RLFFH Series) Wired Remote Controer UTY-RNNUM Wired Remote Controer UTY-RVNUM Simpe Remote Controer UTY-RSNUM The wired remote controer with its unique ock function and seek design provides fu feature access to property managers, buiding owners, and faciity maintenance, as we as providing basic comfort features to tenants, empoyees, and teachers. Features a arge backit LCD dispay and dispays the room temperature. Provides fu feature access to property managers, buiding owners, and faciity maintenance, as we as providing basic comfort features to tenants, empoyees, and teachers. Suitabe when ony basic operations are required for hotes, offices and other paces where there is frequent arriva and departure of occupants. Remote does not aow any timer settings. Touch Pane Remote Contro (Compatibe with System 30RLXEH) Dry Contact Kit (Compatibe with RLS3H and RLFFH Series) Interface Kit (Compatibe with RLS3H Series) Wired Remote (Touch Pane) UTY-RNRUZ1 Features a arge backit LCD dispay and dispays the room temperature. Provides fu feature access to property managers, buiding owners, and faciity maintenance, as we as providing basic comfort features to tenants, empoyees, and teachers. Dry Contact Wire Kit UTY-XWZXZ5 Turns system on or off using a normay open circuit. For exampe in home automation, BMS integration of ony On/Off operation, occupancy sensor, key card switch, or ead-ag contro of other heating/cooing devices. Interface Kit UTY-TWBXF1 Required to connect the ASU9RLS3, ASU12RLS3 and ASU15RLS3 to Wired Remotes UTY-RNNUM and UTY-RVNUM, Dry Contact Wire Kit UTY-XWZXZ5, and Simpe Remote Contro UTY-RSNUM. Interface Kit (Compatibe with RLXFWH and RLXEH Series) Dry Contact Wire Kit * UTY-XWZX Turns system on or off using a normay open circuit. For exampe in home automation, BMS integration of ony On/Off operation, occupancy sensor, key card switch, or ead-ag contro of other heating/cooing devices. Interface Kits (Compatibe with System 30RLXEH) Interface Kit UTY-XCSXZ1 Required to connect ASU30RLE to Wired Touch Pane Remote UTY- RNRUZ1, Wired Remote UTY-RVNUM, Wired Remote UTY-RNNUM, Simpe Remote UTY-RSNUM, Dry Contact Wire Kit UTY-XWZX, and Lead Lag Contro function^. Interface Kit Box UTY-GXXB Used to concea Interface Kit UTY-XCSXZ1. Unit Input/Output Connector UTY-XWZXZ3 Gives the abiity to imit the noise of the unit*, stop the outdoor unit, imit power consumption*, contro the operating mode (Htg/Cg), or use output status to see if the compressor is running. You wi need to order a kit for each option. *Wi reduce capacity. Muti-Zone Mode Accessories (Compatibe with AOU18/24/3RLXFZH) Sma Wa (RLF1 -, 9, 12k BTU) Large Wa (18k BTU) Cassette Sim Duct Foor Mount Remote Contros UTY-RNNUM Wired Remote Contro * UTY-RVNUM Wired Remote Contro UTY-RSNUM Simpe Remote Contro * UTY-LNHUM Wireess Remote Contro UTY-XSZX Remote Sensor UTY-LRHUM Receiver Unit Interface Kits UTY-XWZX Dry Contact Wire Kit UTY-XWZXZ5 Dry Contact Wire Kit * UTY-XCBXZ2 Interface Kit UTD-ECS5A Sim Duct Connector Kit Fresh Air Intake Kits UTZ-KXGC High Humidity Insuation Kit UTR-YDZB Air Outet Shutter Pate UTZ-VXAA Fresh Air Intake Kit Misceaneous K3PST 3-Poe Singe Throw Safety Switch UTD-GXSA-W Auto Louver Grie Kit (for ARU9, 12) UTD-GXSB-W Auto Louver Grie Kit (for ARU18) * Wa mounted ASU, 9, and 12RLF1 require accessory interface kit #UTY-XCBXZ2 in order to connect these devices to them. 1 Ony muti-zone modes greater than specific seria numbers are compatibe with UTY-RVNUM. See Service Buetin 0031 for seria number compatibiity. ^ Wired remotes cannot be used when using this feature. This incudes UTY-RNRUZ1, UTY-RVNUM, UTY-RNNUM, UTY-RSNUM.

16 It s Green and It s In There! Year Round Comfort Cruise Contro Cean Air Rebates Timer Savings Osciating Fan Earth Friendy Year Round Comfort Heat pumps provide both heating and cooing for year round comfort in most cimates. Cruise Contro Compressors ony run as fast as they need to hande the cooing or heating demand. Cean Air High performance fiters remove dust, odor and improve indoor air quaity. Timer 24-hour prograabe timer aows for on/off cyce contro of system. Earth Friendy Low ozone depeting potentia (ODP) refrigerant R410a used in a modes. Osciating Fan Auto Louver redirects airfow with up and down. Savings High energy efficiencies sash utiity bis by up to 25%. Rebates Many utiity companies offer rebates for instaing energy efficient equipment. The Fujitsu ogo is a registered trademark of Fujitsu Limited. The Hacyon ogo and name is a trademark of Fujitsu Genera America, Inc. Copyright 201 Fujitsu Genera America, Inc. Fujitsu s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information without notice and without incurring any obigations. Distributed by: Fujitsu Genera America, Inc. 353 Route 4 West Fairfied, NJ 0004 Te: (93) Emai: hvac@fujitsugenera.com Printed in the USA Rev. /201 Part #-2-FG205

Hybrid Flex Inverter System Dual, Tri and Quad Zone Mix & Match Flexibility. Use mini-splits just about any place that requires comfort!

Hybrid Flex Inverter System Dual, Tri and Quad Zone Mix & Match Flexibility. Use mini-splits just about any place that requires comfort! Hybrid Fex Inverter System Dua, Tri and Quad Zone Mix & Match Fexibiity Mini-Spit Air Conditioners and s AOU18RLXFZ AOU24RLXFZ Use mini-spits just about any pace that requires comfort! Oder homes New construction

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps Mini-Spit Air Conditioners and s for Residentia and Light Coercia Appications 3 y revoutionizing energy efficient home TAbe of ConTenTS comfort. features Mini-Spits Defined... 4 Individua Zoning... 6 Comfort

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps Mini-Spit Air Conditioners and s for Residentia and Light Coercia Appications 3 Quiety revoutionizing energy-efficient home TAbe of ConTenTS comfort. features Mini-Spits Defined... 4 Individua Zoning...

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps Hybrid Fex Inverter System 48,000 BTU 8-Zone Mix & Match Fexibiity Mini-Spit Air Conditioners and s Wa Mounted Sim Duct Compact Cassette For over 35 years, Fujitsu has been making the hottest paces coo

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps For over 35 years, Fujitsu has been making the hottest paces coo and the cooest paces more comfortabe. Mini-Spit Air Conditioners and s Fujitsu: The Smart Choice in Whoe Home Comfort As much as haf of

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps Mini-Split Air Conditioners and s for Residential and Light Coercial Applications 3 ly revolutionizing energy efficient home TABLE OF CONTENTS comfort. FEATURES Mini-Splits Defined... 4 Individual Zoning...

More information

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications Mini-Split Air Conditioners and s for Residential and Light Commercial Applications 3 TABLE OF CONTENTS FEATURES Mini-Splits Defined... 4 Individual Zoning... 6 Comfort Solution... 8 Energy Efficient...

More information

MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS 3 TABLE OF CONTENTS QUIETLY REVOLUTIONIZING ENERGY-EFFICIENT HOME COMFORT. FEATURES Mini-Splits Defined... 4 Individual

More information

Auto Louver : Up/Fown Auto Mode Minimum Heat Mode Economy Mode

Auto Louver : Up/Fown Auto Mode Minimum Heat Mode Economy Mode gh-efficiency Multi-Zone systems Dual, Tri and Quad Zone Mix & Match Flexibility y e systems are highl These multi-zoncombinations ALLOWABLE for solution t the on combinations based btu flexible and represen

More information

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications Mini-Split Air Conditioners and s for Residential and Light Commercial Applications 3 TABLE OF CONTENTS FEATURES Mini-Splits Defined... 4 Individual Zoning... 6 Comfort Solution... 8 Energy Efficient...

More information

VRV IV S-series HEAT PUMP SYSTEMS LIGHT COMMERCIAL / RESIDENTIAL

VRV IV S-series HEAT PUMP SYSTEMS LIGHT COMMERCIAL / RESIDENTIAL VRV IV S-series HEAT PUMP SYSTEMS LIGHT COMMERCIAL / RESIDENTIAL 2 What is Daikin VRV IV S-series? One fexibe package Daikin VRV IV S-series is a compement to the renowned Daikin VRV famiy of cooing and

More information

Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps For over 35 years, Fujitsu has been making the hottest aces coo and the cooest aces more comfortabe. MiniSit Air Conditioners and Heat Pums Fujitsu: The Smart Choice in Whoe Home Comfort As much as haf

More information

https://portal.fujitsugeneral.com

https://portal.fujitsugeneral.com https://portal.fujitsugeneral.com Is Your Company on Fujitsu s Toolbox? Online Training Sales Leads with Consumer Referrals Online Documentation Online Troubleshooting Downloadable Technical Bulletins

More information

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1. HVAC Guide Specifications Mini-Split Multi-Zone Section 15700 Mechanical HVAC Evaporator Size Range: 7K 24K BTU Fujitsu Evaporator Model Number: ASU7RLF1, ASU9RLF1, ASU9RLS2, ASU12RLF1, ASU12RLS2, ASU15RLS2,

More information

SKYSTAR water cassette Main components:

SKYSTAR water cassette Main components: Innovative and fascinating design, six different modes, high contro fexibiity, ease of maintenance: the new SKYSTR water cassette is the resut of significant technica and design research focused on providing

More information

ANALOGUE FIRE DETECTION SENTRI SYSTEM

ANALOGUE FIRE DETECTION SENTRI SYSTEM ANALOGUE FIRE DETECTION SENTRI SYSTEM SMS SMS is a Honeywe Life Safety Systems business, based in the UK offering a wide range of market eading fire detection and aarm products. Operating for over 25 years,

More information

Clean and simple waste water removal

Clean and simple waste water removal The cean and simpe way to remove waste water. Wastefo products provide a simpe soution for waste water remova in a variety of environments. Cean and simpe waste water remova cean and simpe waste water

More information

VRV T-Series WATER-COOLED SYSTEMS 10.17

VRV T-Series WATER-COOLED SYSTEMS 10.17 VRV T-Series WATER-COOLED SYSTEMS 10.17 Why Consider a Daikin VRV T-Series Water Cooed System? One Fexibe Package The Daikin VRV T-Series Water Cooed is a fexibe and moduar energy saving aternative to

More information

VRV AURORA AIR-COOLED SYSTEMS

VRV AURORA AIR-COOLED SYSTEMS VRV AURORA AIR-COOLED SYSTEMS Appications: COLD CLIMATE RESIDENTIAL OFFICE RETAIL SCHOOLS DAIKIN VRV AURORA Engineered for Cod Cimate and Heating Dominant Appications Subarctic / Arctic 15% North American

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

BC80A compact product catalog.

BC80A compact product catalog. BC80A compact product cataog. Buiding Technoogies 1 A wide range of appications. BC80A comprises an extensive product portfoio and can be instaed in various buiding types. For instance, it is a perfect

More information

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced.

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced. [ Air ] [ Water ] [ Earth ] Buderus GA124 GA244 Gas Boiers Seaed Combustion Draft Induced [ Buderus ] Quaity Doesn t Cost It Saves! High Efficiency AFUEs Above 85% No Chimney... No Probem Whisper Quiet

More information

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013 MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL APRIL 2013 Important: Pease read carefuy on receipt of product and keep in a safe pace. heatingthroughinnovation. Contents 1.0 Genera Information

More information

by Honeywell THE VIGILON SYSTEM BROCHURE

by Honeywell THE VIGILON SYSTEM BROCHURE by Honeywe THE VIGILON SYSTEM BROCHURE THE VIGILON SYSTEM BROCHURE by Honeywe The Vigion System Gent by Honeywe s Vigion system is the most comprehensive ife safety system avaiabe in the market today.

More information

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING I N N O V A T I O N T H R O U G H E X P E R I E N C E HAZARDOUS AREA SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING TANK/VESSEL CLEANING MARINE GROWTH REMOVAL ABRASIVE CUTTING

More information

XLTH SERIES: EXTRA LOW TEMPERATURE HEATING DOWN TO -15 F FLOOR MOUNT SYSTEMS 9RLFFH, 12RLFFH, 15RLFFH

XLTH SERIES: EXTRA LOW TEMPERATURE HEATING DOWN TO -15 F FLOOR MOUNT SYSTEMS 9RLFFH, 12RLFFH, 15RLFFH XLTH SERIES: EXTR LO TEMPERTURE HETING DON TO -15 F LL MOUNT SYSTEMS 9RLS3H, 12RLS3H, 15RLS3H 18RLXFH, 24RLXFH, 30RLXEH FLOOR MOUNT SYSTEMS 9RLFFH, 12RLFFH, 15RLFFH MULTI-ZONE SYSTEMS OU18RLXFZH, OU24RLXFZH,

More information

ELECTRIC UNDERFLOOR HEATING

ELECTRIC UNDERFLOOR HEATING MYSON MYSON MYSON Eastern Avenue, Team Vaey, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, saes@myson.co.uk, www.myson.co.uk ELECTRIC UNDERFLOOR HEATING INSTALLATION MANUAL PLEASE

More information

INSTRUCTION MANUAL AND WARRANTY

INSTRUCTION MANUAL AND WARRANTY Brezza Tabetop Air Circuator with Adjustabe Osciation Mode No: OZF2 INSTRUCTION MANUAL AND WARRANTY Copyright 2011, Ozeri Important Safety Instructions Thank you for purchasing the Ozeri Tabetop Air Circuator.

More information

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS 9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS Basics Refrigeration is the remova of heat from a materia or space, so that it's temperature is ower than that of it's surroundings. When refrigerant absorbs

More information

AUTOMATIC MARINE AND RV TOILETS

AUTOMATIC MARINE AND RV TOILETS AUTOMATIC MARINE AND RV TOILETS 1 THE INVENTOR, DESIGNER AND MANUFACTURER SINCE 1958, SFA SANIFLO IS THE WORLD S LEADER OF MACERATING TOILETS FOR THE MARINE AND RECREATIONAL VEHICLE INDUSTRIES Speciay

More information

DC Disconnect with remote control and arc fault detection PVREM-...-AF1

DC Disconnect with remote control and arc fault detection PVREM-...-AF1 DC Disconnect with remote contro and arc faut detection PVRE-...-1 Description The powerfu DC Disconnect PVRE-...-1 on a hybrid basis aows disconnection of the DC side of a photovotaic system in proximity

More information

INDIA S MOST POWER SAVING INVERTER AC

INDIA S MOST POWER SAVING INVERTER AC INDIA S MOST POWER SAVING INVERTER AC 31 32 IDU ODU MODEL NOMENCLATURE GSC 12 GIG 5 DGOG GSC 18 GIG 5 DGOG GSC 18 FIXH 5 GGPG GSC 12 FIXH 7 GGPG GIC 12 BAH 8 GGQG GIC 24 BAH 5 GWQG GIC 18 LAH 5 GWQG GSC

More information

DESIGN AND APPLICATION GUIDE VISUAL ALARMS

DESIGN AND APPLICATION GUIDE VISUAL ALARMS DESIGN AND APPLICATION GUIDE VISUAL ALARMS This guide offers an overview of the new reguations for the seection and design of visua aarms devices (aso known as VADs) in fire detection and aarm systems.

More information

LASER Fan Coil Unit. 2 & 4 pipe system A complete range from 1.1 kw up to 9.9 kw. Thermostats

LASER Fan Coil Unit. 2 & 4 pipe system A complete range from 1.1 kw up to 9.9 kw. Thermostats water systems LASER Fan Coi Unit 2 & 4 pipe system A compete range from 1.1 kw up to 9.9 kw FX03 Termina unit controer BacNET and N2 Metasys network compatibe Technica features CSL00 (Buit in) CSR00 (Wa

More information

CONVENTIONAL FIRE DETECTION

CONVENTIONAL FIRE DETECTION FIRE DETECTION Systems The SMS conventiona range of products is designed to meet the requirements of arge domestic and sma commercia instaations as we as provide the abiity to upgrade or expand existing

More information

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service:

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service: ELECTRORAD UK LTD Unit 1, Cayton Park, Cayton Wood Rise, West Park, Leeds, LS16 6RF T: 0844 479 0055, info@eectrorad.co.uk, www.eectrorad.co.uk Eectrorad Digi-Line Instaation, Operating & Instruction Manua

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

ASPIRATING SMOKE DETECTION SYSTEMS

ASPIRATING SMOKE DETECTION SYSTEMS ASPIRATING SMOKE DETECTION SYSTEMS Aspirating Smoke Detection FAAST TM LT FAAST LT deivers a fexibe soution for appications where standard detection methods are prone to faiure or fase aarm Designed with

More information

Small is beautiful and useful anywhere... Electric "Point of Use" Water Heaters "Open-Outlet" for single outlet "Unvented" for one or more outlets

Small is beautiful and useful anywhere... Electric Point of Use Water Heaters Open-Outlet for single outlet Unvented for one or more outlets S T I E B E L E L T R O N WATER HEATING Sma is beautifu and usefu anywhere... Eectric "Point of Use" Water Heaters "Open-Outet" for singe outet "Unvented" for one or more outets Sma is beautifu - Point

More information

Domestic applications of gas

Domestic applications of gas gasnetworks.ie Domestic appications of gas Advantages of natura gas versus other types of energy 2 Natura gas: The cimate-friendy aternative 3 Why natura gas? Natura gas is the most environmentay friendy

More information

ARG 1

ARG   1 www..com gas monitoring system Sma in size, yet very skifu anayser it has the best capabiities/price ratio. mamos is our aternative for arge, intricate CEMS systems, as it does not fa behind them concerning

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

EPLE Air-Cooled. Chillers. EUWA*5-24KZ / EUWY*5-24KZ Hydronic systems

EPLE Air-Cooled. Chillers. EUWA*5-24KZ / EUWY*5-24KZ Hydronic systems EPLE0305 AirCooed Chiers EUWA*524KZ / EUWY*524KZ Hydronic systems Daikin water chiers are renowned throughout the word for their advanced technoogy, reiabiity and fexibe design characteristics a rare combination

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser soo TM detectortesters A compete range of test and maintenance equipment for smoke, heat and CO detectors. Testing equipment must be proven to be safe for the engineer and the system, it needs to be cost-effective,

More information

utomatic Ceaning SRDES HOT IR PELLET STOVE High efficiency and eegant design Long asting stee body Combustion with draught fan utomatic fue feed utomatic ignition system Indoor remote controer dvanced

More information

DAIKIN ALTHERMA - LOW TEMPERATURE (LT)

DAIKIN ALTHERMA - LOW TEMPERATURE (LT) DAIKIN ALTHERMA - LOW TEMPERATURE (LT) HOW DOES THE DAIKIN ALTHERMA AIR TO WATER HEAT PUMP WORK? Daikin Atherma LT Spit A / OUTDOOR UNIT : AN EFFICIENT USE OF ENERGY FROM THE AIR Daikin Atherma uses a

More information

Take control with... Energy Efficient Controls

Take control with... Energy Efficient Controls Take contro with... Energy Efficient Contros 1 A LEGACY OF ENERGY EFFICIENCY AND COST SAVINGS Nuaire and ventiation contros go back a ong way, starting from the days when the thenowner Brian Moss was a

More information

Fire Alarm Panel - User Manual

Fire Alarm Panel - User Manual CONTENTS Page No. INTRODUCTION SYSTEM DESIGN AND PLAN GENERAL FEATURES MECHANICAL CONSTRUCTION INSTALLATION AND COMMISSIONING INSTALLATION COMMISSIONING OPERATION POWER CONDITION ZONE LOOP CONDITION KEY

More information

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units ANCILLARY DEVICES Contents Fire System Document Box EN54-4 Approved Power Suppy Units Transformer Rectifier 24v Door Retainer Power Suppy Units Door Hoders Fire System Document Box The new fire system

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

ACTIVESMART FRIDGE 900MM FRENCH DOOR SLIDE-IN WITH ICE & WATER

ACTIVESMART FRIDGE 900MM FRENCH DOOR SLIDE-IN WITH ICE & WATER QUIK REFERENE GUIE FETURES ENEFITS SPEIFITIONS RS90U1 Seamess Integration The Side-in series minimises gaps through heavy-duty Finish Stainess Stee Pre-finished TIVESRT FRIGE 900 FRENH OOR SLIE-IN WITH

More information

Classic ECO. Eco Series -86 C Ultra-low Freezer KM-DU34H1E

Classic ECO. Eco Series -86 C Ultra-low Freezer KM-DU34H1E Eco Series -86 Utra-ow Freezer KM-DU34H1E MO-19 incubator series Used by the university of Maastricht in their "in vitro project", in which they created the words first aboratory grown hamburger. Save

More information

Commercial Upright Vacuums

Commercial Upright Vacuums Commercia Upright Vacuums Powr-Fite offers 19 upright modes. Seect the features and benefits for your requirements. Tacony Inc., A Rights Reserved X8709 4/2011 800.880.2913 www.powr-fite.com Dua motor

More information

a guide to watering your garden

a guide to watering your garden a guide to watering your garden The diagram beow shows how the amount of water in a garden is constanty changing. A pant draws a its water from the soi so you have to make sure that there is enough water

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Thermo shaker PHMP/ PHMP-4

Thermo shaker PHMP/ PHMP-4 Thermo shaker PHMP/ PHMP-4 For version V.2GW Contents 1 Safety...3 2 Genera Information...5 3 Getting Started...6 4 Operation of PHMP/PHMP-4...7 5 Specifications...9 6 Guarantee and service...10 Version

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

INUI-LEDSDL10 Specification

INUI-LEDSDL10 Specification INUI-LEDSDL10 Specification Mode No.: INUI- LED-SDL-10-xx-xx Input Votage (input AC or DC) Wattage SMD LED chip (Watt) xxx Light mode: LED Down Light Company Brand INUI Features: 1. Product Name:LED Down

More information

ASPIRATING SMOKE DETECTION SYSTEMS

ASPIRATING SMOKE DETECTION SYSTEMS ASPIRATING SMOKE DETECTION SYSTEMS Aspirating Smoke Detection FAAST LT-200 (Standaone) Fire Aarm Aspirating Sensing Technoogy The FAAST LT-200 Aspirating Smoke Detector is designed with the instaer and

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

PRODUCT CATALOG MEDICAL REFRIGERATOR. LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. labstac.

PRODUCT CATALOG MEDICAL REFRIGERATOR. LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. labstac. PRODUCT CATALOG MEDICAL REFRIGERATOR LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. contact@abstac.com abstac.com MEDICAL REFRIGERATOR Engineered to meet the demanding requirements

More information

. Ev d & AUTOMATIC WASHER

. Ev d & AUTOMATIC WASHER c. Ev d & AUTOMATIC WASHER Design 2000 Large Capacity Mode LA61OOXS eezers, Refrrgerator-Freezers, Ice Makers, Dishwashers. Buit-In Ovens and Surface Units, Ranges, Microwave Ovens, Trash Compactors, Room

More information

SenTRI ONE CONTROL PANEL

SenTRI ONE CONTROL PANEL ANALOGUE ADDRESSABLE FIRE SYSTEMS SenTRI ONE CONTROL PANEL Designed to compy with EN54 parts 2 and 4 Up to 127 devices on the oop A devices connect onto the same two core oop, separate sounder wiring circuits

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

List of Contents Air Top 2000 NOTE

List of Contents Air Top 2000 NOTE List of Contents Air Top 2000 Technica changes in this issue of the manua compared with its previous issue are identified with a vertica change bar on the efthand side of coumns. Air Top 2000 List of Contents

More information

Motion & Presence Detectors

Motion & Presence Detectors Motion & Presence Detectors the success is in the system 2 Hager motion and presence detectors are suitabe for residentia and commercia, indoor and outdoor appications. They can be utiised to activate

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Thermo shaker PHMP/ PHMP-4

Thermo shaker PHMP/ PHMP-4 Thermo shaker PHMP/ PHMP-4 For versions V.5GW (PHMP) V.3GW (PHMP-4) Contents 1 Safety...3 2 Genera Information...5 3 Getting Started...6 4 Operation of PHMP/PHMP-4...7 5 Specifications...9 6 Guarantee

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

DUCTLESS FULL LINE CATALOG

DUCTLESS FULL LINE CATALOG DUCTLESS FULL LINE CATALOG Spring 2016 Edition 1 Versatile Ductless Systems can increase your sales opportunities Bryant offers a complete line of ductless HVAC systems designed to make any space more

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

Our home standard. Your home is where our heart is...

Our home standard. Your home is where our heart is... Our home standard. Your home is where our heart is... What is the Onward Home Standard? Our tenants have heped us to write our Home Standard so that you know what to expect when we ook after and improve

More information

Underc Dishwasher. IMPORTANT: Read and save these instryctions. 8

Underc Dishwasher. IMPORTANT: Read and save these instryctions. 8 MPORTANT: Read and save these instryctions. 8 MPORTANT: nstaer: Leave nstaation nstructions with the homeowner. Homeowner: Keep nstaation nstructions for future reference. Save nstaation nstructions for

More information

36 Electric Modular Downdraft Cooktop

36 Electric Modular Downdraft Cooktop MPORTANT: Read and save these instructions. MPORTANT: nstaer: Leave nstaation nstructions with the Homeowner. Homeowner: Keep nstaation nstructions for future reference. Save nstaation nstructtons for

More information

Think FATI for Hot Solutions

Think FATI for Hot Solutions Think FATI for Hot Soutions COMPANY PROFILE F.A.T.I. (Fabbrica Apparecchiature Termoeettriche Industriai) founded in 1945 at Mian - Itay, quicky estabished itsef as an industry eader in the fied of Heating

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS. Green Refrigerant

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS. Green Refrigerant THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS Modes: T2H to TH Up to.2 EER Heating Capacities: 22,2 to 5, BTUH Cooing Capacities: 22, to 57,5 BTUH Green Refrigerant R-A The Bard Wa-Mount Heat Pump is a sef-contained

More information

Inspired LED Emergency Lighting Solutions

Inspired LED Emergency Lighting Solutions Inspired LED Emergency Lighting Soutions Moduar & Energy Efficient Serenga Escape is a high specification, practica and contemporary LED based emergency exit sign system - idea for modern commercia and

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

Smarts Ali47. Aluminium Windows

Smarts Ali47. Aluminium Windows Smarts Ai47 Auminium Windows Sim & Styish Auminium Windows Our Ai 47 Windows are very popuar, and offer everything you woud expect from a quaity auminium window. The inherent strength of the auminium means

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION TWO-STAGE ULTRA MID-EFFICIENCY GAS-FIRED VARIABLE SPEED FURNACES Upfow / Horizonta Modes: P*DU - V / G8V Up To 130 MBH Output CONTENTS GENERAL INFORMATION... 3 UNIT INSTALLATION...

More information

30 and 36 m Sealed Burner

30 and 36 m Sealed Burner IMPORTANT: Read and save these instructions. IMPORTANT: Instaer: Leave Instaation Instructions with the homeowner. Homeowner: Keep Instaation Instructions for future reference. Save Instaation Instructions

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

Forest help when you need it To order or for more information visit or call

Forest help when you need it To order or for more information visit  or call Forest hep when you need it product cataogue How can I hep? To order or for more information visit www.forestinkine.co.uk or ca 01594 812505 Free Deivery visit www.forestinkine.co.uk or ca 01594 812505

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

Undercounter Dishwasher

Undercounter Dishwasher IMPORTANT: Read and save these instructions. IMPORTANT: Instaer: Leave Instaation Instructions with the homeowner. Homeowner: Keep Instaation Instructions for future reference, Save Instaation Instructions

More information

UseAndCare. TLidl Call our Consumer Assistance Center with questions or comments.

UseAndCare. TLidl Call our Consumer Assistance Center with questions or comments. TLid 01 Home Appiances 2 UseAndCare Tabe of Contents (compete).................. 2 A Note to You................ 2 Refrigerator Safety....... 3 Parts and Features....... 4 Before Using Your Refrigerator...................

More information

UseAndCare. l Call our Consumer Assistance Center with questlons or comments. 18 TO 20 NO-FROST TOP FREEZER REFRIGERATOR

UseAndCare. l Call our Consumer Assistance Center with questlons or comments. 18 TO 20 NO-FROST TOP FREEZER REFRIGERATOR Y?bf 4a Home Appiances o@ UseAndCare Tabe of Contents (compete).................. 2 A Note to You................ 2 Refrigerator Safety....... 3 Parts and Features....... 4 Before Using Your Refrigerator...

More information

Turbosteam iron steam/spray/steam boost

Turbosteam iron steam/spray/steam boost RN40697MUK Rev4_Instruction Book 08/12/2011 10:36 Page 1 Upon registration with Morphy Richards (UK & ROI ony) Register onine for your 3 year guarantee. See back of this instruction book for detais. (UK

More information

InverterFlex SERIES InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms InverterFlex SERIES InverterFlex Systems condition up to five rooms Floor & Ceiling Console Outdoor Unit Rated up to 22 SEER Wireless remote included with each indoor unit Ducted Unit Multi-Zone Heat Pumps

More information

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser soo TM detectortesters A compete range of test and maintenance equipment for smoke, heat and CO detectors. Testing equipment must be proven to be safe for the engineer and the system, it needs to be cost-effective,

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information