1 General information

Size: px
Start display at page:

Download "1 General information"

Transcription

1 Air-cooled modular chiller unit 50Hz MCAC-ATSM Content 1 General information Features Specification Dimension Refrigeration system drawing Piping diagram Wiring diagrams Electric characteristics Capacity tables Exploded view Troubleshooting Installation Commissioning Maintenance Control system Appendix

2 MCAC-ATSM General information Air-cooled modular chiller unit 50Hz 1.1Nomenclature M G C T S L - D 60 W / R N1 - A Design Serial Number Refrigerant type N1:R410A Omit for R22 Power Supply R: 380~415V, 50Hz, 3N D: 220V, 60Hz, 3N Outdoor Unit Rated cooling capacity (kw) The special function code D: Digital scroll F: Constant feed V: Inverter system The special function code S: Hydraulic mole L: Low temperature cooling H: Heat recovery Omit for T1 condition T: T3 condition The heat exchanger type A: Plate heat exchanger B: Tube and shell C: Tube in tube heat exchanger Light chiller system Midea 1.2 Product schedule No Model Power supply Heat exchanger type Maximum combinations Maximum capacity(kw) Wired controller 1 MGB-F25W/RN1 380~415V/3ph/50Hz Tube in tube KJR-08B/BE 2 MGB-D25W/RN1 380~415V/3ph/50Hz Tube in tube KJR-08B/BE 3 MGB-F30W/RN1 380~415V/3ph/50Hz Tube in tube KJR-08B/BE 4 MGB-D30W/RN1 380~415V/3ph/50Hz Tube in tube KJR-08B/BE 5 MGCSL-F30W/RN1 380~415V/3ph/50Hz Tube in tube 1 30 KJR-120A/MBE 6 MGCSL-D30W/RN1 380~415V/3ph/50Hz Tube in tube 1 30 KJR-120A/MBE 7 MGB-F55W/RN1 380~400V/3ph/50Hz Tube and shell KJR-08B/BE 8 MGB-F60W/RN1 380~400V/3ph/50Hz Tube and shell KJR-08B/BE 9 MGB-F65W/RN1 380~400V/3ph/50Hz Tube and shell KJR-08B/BE 10 MGB-D65W/RN1 380~415V/3ph/50Hz Tube and shell KJR-120A/MBE 11 MGB-F130W/RN1 380~400V/3ph/50Hz Tube and shell KJR-08B/BE 12 MGB-F200W/RN1 380~400V/3ph/50Hz Tube and shell KJR-08B/BE 13 MGBT-F250W/RN1 380~400V/3ph/50Hz Tube and shell KJR-120A/MBE 3

3 Air-cooled modular chiller unit 50Hz 1.3 External appearance: MCAC-ATSM New 30KW module 25/30KW module 55/60/65KW module 130KW module 200KW module 250KW module 4

4 MCAC-ATSM Features Air-cooled modular chiller unit 50Hz 1). Low ambient temperature cooling function (Only for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) The ambient temperature is down to -10 in cooling mode, the cooling operating temperature up to 52 C in tropical model and heating down to -10 C ambient by added one board (see picture1). Wide ambient temperature range is selectable by adjustable address between different conditions to meet different requirements. Mode Ambient temp. Normally(S8 address OFF) 10~46 Cooling T3 condition 10~52 Low temp. (S8 address ON) -10~46 Heating -10~21 Picture1 2). Wide range of outlet water temperature (For MGCSL-F(D)30W/RN1,MGB-D65W/RN1, MGB-F250W/RN1) Cooling: 5~17 C (Set in factory), 0~17 C can be available by switch the S5 on PCB, the antifreeze must be put into pipeline. Heating: 40~50 C (Set in factory), 22~50 C can be available by switch the address. Mode Cooling(S5 address) Heating(S4 address) Outlet water temp. Normally(OFF) 5~17 Low water temp.(on) 0~17 Normally(OFF) 45~50 Low water temp. (ON) 22~50 Picture2 3).Built-in hydraulic module (Only for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) The unit built-in hydraulic module to simplified installation, save space and beautification appearance, simultaneous effectively reduce installation costs and covering area. auto-air exchanse valve Fan coil unit Fan coil unit 2-way valve Water pump Expansion tank Y-shaped filiter Water-flow valve Water replenishing valve 1.5kg<Water replenishing pres<6kg Flexible joint 2-way valve Fan coil unit Double -pipe heat exchanger Safety valve Flexible joint Flexible joint Cutoff valve Flexible joint Fan coil unit Aux. heater Thermometer Manometer This figure for reference purpose only, please in terms of the design rule for field installation. 5

5 Air-cooled modular chiller unit 50Hz MCAC-ATSM ).Humanization remote control (For MGCSL-F(D)30W/RN1,MGB-D65W/RN1, MGB-F250W/RN1) S7 address on PCB should be switched to ON to realize remote control, here are reliable: Remote ON/OFF, remote heating and cooling mode selection, remote alarm. The customer can simply and conveniently control the module and acquire the running information on real time in door. 5)Digital scroll technique,new type modular air-cooled chiller system. Capacity output is controlled depending on controlling compressor to on/off in traditional modular air-cooled chiller system control. The precision of the control mode is not very good, and the compressor is frequently on and off, which is very bad for the compressor s life. Digital scroll modular air-cooled chiller system breaks traditional design, which is inconceivably designed with digital scroll compressor and constant scroll compressor parallel connection. the system can achieve linear capacity adjustment within 0.5%-100%,the scope is widest in industry. When the system operates at the part-load, the system can accurately adjust cooling and heating capacity output basing on actual requirement of the indoor room. 6).Modular design, flexible combination, more convenient for design and installation. The unit adopt modular design, which can makes more unit connect together. The unit can combine 16 separate module(25, kw module) or 8 module(250kw module).cooling(heating) capacity can increase step by step by 5KW per each time within 25kW-2000kW,meanwhile every separate module can operate as main unit, also each module can be a slave unit with modules combination, more convenient for design and installation. Max 8 modules 250KW 250KW 2000KW 7).The maximum combination of the system consists of 1 main unit and 15 slave units for 25, and 65KW module, 1 main unit and 7 slave units for 130KW module, 1 main unit and 4 slave units for 200KW module,1 main unit and 7 slave units for 250KW module. Easy connection between main unit and slave units. All the units can be connected together with a wired controller in series type. Using three-core shielded twisted wire as communication wire. Water outlet temp. Water outlet temp. Water outlet temp. Total water outlet temp. (Just for master unit) Three-core shielding twisted pair Total water outlet temp. (Just for master unit) Three-core shielding twisted pair Total water outlet temp. (Just for master unit) Wired controller 6

6 MCAC-ATSM Air-cooled modular chiller unit 50Hz 8).Environmental care Ecological R410A refrigerant. Chlorine-free and environmental friendly refrigerant, zero ozone depletion potential. High density refrigerant, therefore, less refrigerant required. Leak-tight refrigerant circuit, Brazed refrigerant connections for increased leak-tightness. 9) Economical operation New design adopts electronic expansion valve precise refrigerant control in wider range. Electronic expansion valve allows operation at lower condensing pressure, adjustment can be made fast linear response, making the system more stable output, the indoor temperature more uniform, and enhance human comfortable. 10).Compact structure Air cooled modular chiller structure are compact, light weight. The system adopts tube in tube, shell and tube heat exchanger, not only greatly enhanced the transfer performance, but also reduce the unit weight, the lightest single module only has 380kg. The characteristic of unit decided cooling tower is not needed, not only reduced installation costs, but also resolved the cooling tower generated noise when running. 11).Back up function When unit is failure If master unit fails, all the units will stop. If one slave unit fails, this unit will stop but the others will keep running. When the master unit fails, any of the slave one can be set as the master unit by manual setting. When unit is under protection If master unit s protection occurs, this unit will stop but the others will keep running. If slave unit s protection occurs, this unit will stop but the others will keep running. ( Except PE, P9 protection happen) Master Slave Master Slave 12).Strong micro-computer intelligent control and monitor function. Optimizing the design of system and using varieties of protection devices, to make the system more safe and reliable. 13). Superior reliability System will be more reliable with new type efficient heat exchanger. 7

7 Air-cooled modular chiller unit 50Hz MCAC-ATSM Evaporator of 25KW and 30KW module adopts tube in tube heat exchanger,evaporator of 60kw,120kw and 180kw modules adopt Shell and tube heat exchanger. Tube in tube heat exchanger Shell and tube heat exchanger 14). Applicable temperature range Mode Cooling Heating Ambient temperature range Water outlet temperature range Application module 5 C ~17 C (7 C is default) The module with KJR-08B/BE 10 C ~46 C For MGCSL-F(D)30W/RN1,MGBT-D65W/RN1, 0~17 C(0 C must add antifreeze) MGBT-F250W/RN1-10 C ~46 C 5 C ~17 C Only for MGCSL-F(D)30W/RN1-10 C ~21 C Ambient temperature range 45 C ~50 C (45 C is default) 22 C ~50 C The module with KJR-08B/BE For MGCSL-F(D)30W/RN1,MGBT-D65W/RN1, MGBT-F250W/RN1-10 C Cooling range 46 C 10 C Cooling range 46 C -10 C Heating range 21 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C Chilled outlet water temperature can be adjusted by wire controller according to customer s demand. Water outlet temperature range 0 C 5 C 17 C 22 C 45 C 50 C 5 C Cooling range 17 C 45 C Heating range 50 C 0 C Cooling range 17 C 22 C Heating range 50 C 8

8 MCAC-ATSM Specification Air-cooled modular chiller unit 50Hz Model MGB-F25W/RN1 MGB-F30W/RN1 Cooling Capacity kw Btu/h 95, ,300 Heating Capacity kw Power supply V/Ph/Hz /3/50 Power supply Compressor Power input Manual switch A 50 Fuse A 36 Type Scroll (constant speed) Quantity Pieces 2 Model Brand ZP67KCE-TFD-522 Copeland Capacity W Input W Rate current(rla) A Locked rotor Amp(LRA) A 74 2 Cooling kw Cooling rated current A Heating kw Heating rated current A Max. Input consumption A 12.6 Max. Current A 21.8 Refrigerant Condenser (Air side) Evaporator (Water side) Dimension Type R410a Weight kg Refrigerant control Air side heat-exchanger type EXV+ capillary throttle Copper-fin-coil Quantity of fan motor Pieces 1 Air flow volume 10 3 m 3 /h 12 Fan motor input kw 0.3 Water side heat-exchanger type Tube in tube Water resistance loss kpa 60 Water inlet/outlet pipeline inside normal diameter mm DN40 inch 1-1/2 Water flow volume m 3 /h Max. Pressure MPa 1 Water pipe connection type Net(W H D) Packing(W H D) Flexible joint mm inch mm inch Weight Net weight kg 380 9

9 Air-cooled modular chiller unit 50Hz Connection wire Control type Operation weight kg 400 Power wire mm 2 No Signal wire mm 2 No core Wired controller MCAC-ATSM ) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 3) Power supply phase sequence protection. 4) Anti-frozen protection in cooling mode. 5) Anti-frozen protection in Winter. Safety protection device 6) Protection for compressor over current. 7) Protection for compressor overload. 8) Outlet and inlet water temperature difference protection. 9) Compressor discharge temp. protection. 10) Water flow cut-off protection. 11) Sensor malfunction protection. Noise level(semi-anechoic ) db(a) 65 Operation water temp Cooling:5~17 Heating:45~50 Ambient temp Cooling:10~46 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 10

10 MCAC-ATSM Air-cooled modular chiller unit 50Hz Model MGB-D25W/RN1 MGB-D30W/RN1 Cooling Capacity kw Btu/h 95, ,300 Heating Capacity kw Power supply V/Ph/Hz /3/50 Power supply Manual switch A 50 Fuse A 36 Type Constant Speed Scroll + Digital Scroll Quantity Pieces 1+1 Model ZP67KCE-TFD-522+ ZPD67KCE-TFD-532 Compressor Power input Brand Copeland Capacity W Input W Rate current(rla) A Locked rotor Amp(LRA) A Cooling kw Cooling rated current A Heating kw Heating rated current A Max. Input consumption A 12.5 Max. Current A 21.5 Refrigerant Condenser (Air side) Evaporator (Water side) Type R410a Weight kg Refrigerant control Air side heat-exchanger type EXV+ capillary throttle Copper-fin-coil Quantity of fan motor Pieces 1 Air flow volume 10 3 m 3 /h 12 Fan motor input kw 0.3 Water side heat-exchanger type Double-pipe heat exchanger Water resistance loss kpa 60 Water inlet/outlet pipeline inside normal diameter mm DN40 inch 1-1/2 Water flow volume m 3 /h Max. Pressure MPa 1 Water pipe connection type Flexible joint Dimension Weight Connection wire Control type Net(W H D) mm inch Packing(W H D) mm inch Net weight kg 380 Operation weight kg 400 Power wire mm 2 No Signal wire mm 2 No core Wired controller 11

11 Air-cooled modular chiller unit 50Hz MCAC-ATSM ) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 3) Power supply phase sequence protection. 4) Anti-frozen protection in cooling mode. 5) Anti-frozen protection in Winter. Safety protection device 6) Protection for compressor over current. 7) Protection for compressor overload. 8) Outlet and inlet water temperature difference protection 9) Compressor discharge temp. protection. 10) Water flow cut-off protection. 11) Sensor malfunction protection. Noise level(semi-anechoic ) db(a) 65 Operation water temp Cooling:5~17 Heating:45~50 Ambient temp Cooling:10~46 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 12

12 MCAC-ATSM Air-cooled modular chiller unit 50Hz Model MGCSL-F30W/RN1 MGCSL-D30W/RN1 Cooling Capacity kw Btu/h 102, ,300 Heating Capacity kw Power supply V/Ph/Hz /3/50 Power supply Manual switch A 50 Fuse A 36 Type Fixed speed Digital Scroll + Fixed speed Quantity Pieces Model ZP67KCE-TFD-522 ZPD67KCE-TFD-532/ ZP67KCE-TFD-522 Compressor Power input Brand Copeland Capacity W Input W Rate current(rla) A Locked rotor Amp(LRA) A 74 2 Cooling kw Cooling rated current A Heating kw Heating rated current A Max. Input consumption A 13.4 Max. Current A 22.5 Refrigerant Condenser (Air side) Evaporator (Water side) Type R410A Weight kg Refrigerant control Air side heat-exchanger type EXV Fin-coil Quantity of fan motor Pieces 1 Air flow volume 10 3 m 3 /h 12 Fan motor input kw 0.55 Water side heat-exchanger type Double-pipe Water resistance loss kpa / Water inlet/outlet pipeline inside normal diameter mm DN40 inch 1-1/2 Water flow volume m 3 /h Max. Pressure MPa 1 Water pipe connection type Flexible joint Dimension Weight Connection wire Control type Net(W H D) mm inch Packing(W H D) mm inch Net weight kg 430 Operation weight kg 450 Power wire mm 2 No Signal wire mm 2 No core with shielding Wired controller 13

13 Air-cooled modular chiller unit 50Hz MCAC-ATSM ) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 3) Power supply phase sequence protection. 4) Anti-frozen protection in cooling mode. 5) Anti-frozen protection in Winter. 6) Protection for compressor over current. 7) Protection for compressor overload. Safety protection device 8) Outlet and inlet water temperature difference protection. 9) Compressor discharge temp. protection. 10) Water flow cut-off protection. 11) Sensor malfunction protection. 12) Low ambient temperature drive-up protection 13) Low-temperature protection of shell-and-tube heat exchanger. Noise level(semi-anechoic ) db(a) 67 Operation water temp Ambient temp Cooling:0~17(0 must add antifreeze) Heating:22~50 Cooling:-10~46 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 14

14 MCAC-ATSM Air-cooled modular chiller unit 50Hz Model MGB-F55W/RN1 MGB-F60W/RN1 MGB-F65W/RN1 Cooling Capacity kw Btu/h 187, , ,780 Heating Capacity kw Power supply V/Ph/Hz /3/50 Power supply Compressor Power input Manual switch A 125 Fuse A 100 Type Fixed speed Scroll Quantity Pieces 2 Model Brand SH140A4ALC Danfoss Capacity W Input W Rate current(rla) A Locked rotor Amp(LRA) A Cooling kw Cooling rated current A Heating kw Heating rated current A Max. Input consumption A 28.2 Max. Current A 47.6 Refrigerant Condenser (Air side) Evaporator (Water side) Type R410a Weight kg 7 2 Refrigerant control Air side heat-exchanger type EXV+ capillary throttle Copper-fin-coil Quantity of fan motor Pieces 2 Air flow volume 10 3 m 3 /h 24 Fan motor input kw 0.65 Water side heat-exchanger type Shell and tube Water resistance loss kpa 15 Water inlet/outlet pipeline inside normal diameter mm DN100 inch 4 Water flow volume m 3 /h Max. Pressure MPa 1 Water pipe connection type Flexible joint Dimension Weight Net(W H D) mm inch Packing(W H D) mm inch Net weight kg 580 Operation weight kg

15 Air-cooled modular chiller unit 50Hz Connection wire Power wire mm 2 No Signal wire mm 2 No core MCAC-ATSM Control type Wired controller 1) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 3) Power supply phase sequence protection. 4) Anti-frozen protection in cooling mode. 5) Anti-frozen protection in Winter. Safety protection device 6) Protection for compressor over current. 7) Protection for compressor overload. 8) Outlet and inlet water temperature difference protection. 9) Compressor discharge temp. protection. 10) Water flow cut-off protection. 11) Sensor malfunction protection. Noise level(semi-anechoic ) db(a) 67 Operation water temp Cooling:5~17 Heating:45~50 Ambient temp Cooling:10~46 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 16

16 MCAC-ATSM Air-cooled modular chiller unit 50Hz Model MGB-D65W/RN1 MGB-F130W/RN1 MGB-F200W/RN1 Cooling Capacity kw Btu/h 221, , ,220 Heating Capacity kw Power supply V/Ph/Hz /3/ /3/ /3/50 Power supply Manual switch A Fuse A Type Scroll (fixed speed+digital scroll) Fixed speed Scroll Fixed speed Scroll Quantity Pieces Compressor Power input Model ZP144KCE-TFD-522 / ZPD72KCE-TFD-433 / ZP67KCE-TFD-420 SH140A4ALC SH140A4ALC Brand Copeland Danfoss Danfoss Capacity kw Input kw Rate current(rla) A Locked rotor Amp(LRA) A Cooling kw Cooling rated current A Heating kw Heating rated current A Max. Input consumption A Max. Current A Type R410a R410a R410a Refrigerant Condenser (Air side) Evaporator (Water side) Weight kg Refrigerant control EXV+ capillary throttle EXV+ capillary throttle EXV+ capillary throttle Air side heat-exchanger type Copper-fin-coil Copper-fin-coil Copper-fin-coil Quantity of fan motor Pieces Air flow volume 10 3 m 3 /h Fan motor input kw Water side heat-exchanger type Shell and tube Shell and tube Shell and tube Water resistance loss kpa Water inlet/outlet pipeline inside normal diameter mm DN100 DN65 DN80 inch 4 2-1/2 3 Water flow volume m 3 /h Max. Pressure MPa Water pipe connection type Flexible joint Flexible joint Flexible joint Dimension Net(W H D) Packing(W H D) mm inch mm inch

17 Air-cooled modular chiller unit 50Hz MCAC-ATSM Weight Net weight kg Operation weight kg Power wire mm 2 No Signal wire mm 2 No core core Control type Wired controller Wired controller 1) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 1) Protection for over-high discharge pressure. 3) Power supply phase sequence 2) Protection for over-low suction protection. pressure. 4) Anti-frozen protection in cooling 3) Power supply phase sequence mode. 5) Anti-frozen protection in Winter. 6) Protection for compressor over protection. 4) Anti-frozen protection in cooling mode. Safety protection device current. 5) Anti-frozen protection in Winter. 7) Protection for compressor 6) Protection for compressor over overload. current. 8) Outlet and inlet water 7) Protection for compressor overload. temperature difference protection. 9) Compressor discharge temp. 8) Outlet and inlet water temperature difference protection. protection. 9) Compressor discharge temp. 10) Water flow cut-off protection. 11)Sensor malfunction protection. 12)Low ambient temperature drive-up protection protection. 10) Water flow cut-off protection. 11) Sensor malfunction protection. 13)Low-temperature protection of shell-and-tube heat exchanger. Noise level(semi-anechoic ) db(a) Operation water temp Cooling:0~17(0 must add antifreeze) Heating:22~50 Cooling:5~17 Heating:45~50 Ambient temp Cooling:10~46 Heating:-10~21 Cooling:10~46 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 18

18 MCAC-ATSM Air-cooled modular chiller unit 50Hz Model MGBT-F250W/RN1 Cooling Capacity kw 250 Btu/h 830,000 Heating Capacity kw 270 Power supply V/Ph/Hz /3/50 Power supply Manual switch A 450 Fuse A 350 Type Scroll (fixed speed) Quantity Copeland 8 Model SH120A4ALC Compressor Brand Copeland Capacity W Input W Rate current(rla) A Locked rotor Amp(LRA) A 177 Cooling kw 78.3 Power input Cooling rated current A Heating kw 80 Heating rated current A 146 Max. Input consumption A Max. Current A Refrigerant Condenser (Air side) Evaporator (Water side) Dimension Weight Connection wire Control type Type R410A Weight kg 15 4 Refrigerant control Air side heat-exchanger type EXV+ capillary throttle Fin-coil Quantity of fan motor Pieces 8 Air flow volume 10 3 m 3 /h 96 Fan motor input kw 5.6 Water side heat-exchanger type Shell-tube Water resistance loss kpa 40 Water inlet/outlet pipeline inside normal diameter mm DN100 inch 4 Water flow volume m 3 /h 43 Max. Pressure MPa 1 Water pipe connection type Net(W H D) Packing(W H D) Flexible joint mm inch mm inch Net weight kg 2450 Operation weight kg 2600 Power wire mm 2 No Signal wire mm 2 No core with shielding Wired controller 19

19 Air-cooled modular chiller unit 50Hz Safety protection device MCAC-ATSM ) Protection for over-high discharge pressure. 2) Protection for over-low suction pressure. 3) Power supply phase sequence protection. 4) Anti-frozen protection in cooling mode. 5) Anti-frozen protection in Winter. 6) Protection for compressor over current. 7) Protection for compressor overload. 8) Outlet and inlet water temperature difference protection. 9) Compressor discharge temp. protection. 10) Water flow cut-off protection. 11)Sensor malfunction protection. 12)Low ambient temperature drive-up protection 13)Low-temperature protection of shell-and-tube heat exchanger. Noise level(semi-anechoic ) db(a) 74 Operation water temp Ambient temp Cooling:0~17(0 must add antifreeze) Heating:22~50 Cooling:10~52 Heating:-10~21 Note: Please refer to the water flow volume in the above table strictly to design and install. All the above data is measured base on the following working condition: 1. cooling mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 7,air inlet temperature of condenser is 35 ; 2. heating mode under normal working condition: water flow m 3 /(h kw), outlet water temperature of chilled water is 45,air inlet temperature of condenser is DB/WB 7/6. 20

20 MCAC-ATSM Dimension Air-cooled modular chiller unit 50Hz 25/30kw module Front view Top view Model Unit A B C D E F MGB-F(D)25W/RN1 MGB-F(D)30W/RN1 mm inch

21 Air-cooled modular chiller unit 50Hz MCAC-ATSM No. Name 1 Top cover 2 Air outlet 3 Air inlet 4 Water outlet 5 Water inlet 6 Electric control box 22

22 MCAC-ATSM KW new module (Only for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) Air-cooled modular chiller unit 50Hz Front view Left view Top view 23

23 Air-cooled modular chiller unit 50Hz MCAC-ATSM NO NAME Make-up Air inlet Air outlet Water inlet Water outlet Drain water inlet 24

24 MCAC-ATSM Air-cooled modular chiller unit 50Hz 55/60/65KW module Front view Top view Model Unit A B C D E F G H I J K MGB-F55W/RN1 MGB-F60W/RN1 MGB-F65W/RN1 MGB-D65W/RN1 mm inch

25 Air-cooled modular chiller unit 50Hz MCAC-ATSM No. Name 1 Top cover 2 Air outlet 3 Air inlet 4 Water outlet 5 Compressor 6 Electric control box 7 Water inlet 26

26 MCAC-ATSM Air-cooled modular chiller unit 50Hz 130KW module Front view Side view Top view Anchor hole Model Unit A B C D E F G H MGB-F130W/RN1 mm inch

27 Air-cooled modular chiller unit 50Hz MCAC-ATSM No. Name 1 Top cover 2 Condenser 3 Compressor 4 Evaporator 5 Electric control box Air inlet 6 Water outlet 7 Water inlet 8 Compressor 28

28 MCAC-ATSM Air-cooled modular chiller unit 50Hz 200KW module Model unit A B C D E F G H MGB-F200W/RN1 Mm inch

29 Air-cooled modular chiller unit 50Hz MCAC-ATSM No. Name 1 Top cover 2 Compressor 3 Evaporator 4 Water outlet 5 Electric control box 6 Water inlet 7 Condenser 30

30 MCAC-ATSM KW module Air-cooled modular chiller unit 50Hz F C D E A Front view B Left view H H A G Hole for anchor boltφ15 Bottom view Model unit A B C D E F G H MGB-F250W/RN1 Mm inch

31 Air-cooled modular chiller unit 50Hz MCAC-ATSM Air outlet Air outlet Air outlet 1 Air outlet Air inlet Air inlet Air inlet Air inlet Air inlet No. Name 1 Top cover 2 Compressor 3 Evaporator 4 Water outlet 5 Electric control box 6 Water inlet 7 Condenser 8 Transportation guard plate (Be removed off after installation) 32

32 MCAC-ATSM Refrigeration system drawing Air-cooled modular chiller unit 50Hz /30KW module refrigeration system sketch drawing Each module has two compressors with two separate units, one double-pipe evaporator for two systems. Fan Discharge pipe 4-way valve A 4-way valve B Condenser Compressor A Compressor B Filter A Filter B Suction pipe Water inlet Water outlet throttle parts A Low pressure cylinder A Low pressure cylinder B Evaporator throttle parts B (Double-pipe heat exchanger) /60/65KW module refrigeration system sketch drawing(fixed speed) Each module has two compressors with two separate units, one shell and tube evaporator for two systems. low pressure cylinder B 4-Way valve B 4" Compressor B Fan A Fan B EXV Water flow direction Capillary Dry type evaporator Condenser Capillary EXV Compressor A 4-Way valve A low pressure cylinder A 33

33 Air-cooled modular chiller unit 50Hz MCAC-ATSM KW digital module refrigeration system sketch drawing (MGB-D65W/RN1) Each module has three compressors with two separate units, one shell and tube evaporator for two systems. Pressure switch low pressure cylinder B Compressor B 4-Way valve B Pressure switch Discharge switch Pressure switch Fan A Fan B T3B EXV Water flow direction Com. A1 digital Pressure switch Com. A2 Capillary T3A Capillary Condenser Pressure switch EXV Dry type evaporator Discharge switch Pressure switch 4-Way valve A low pressure cylinder A KW module refrigeration system sketch drawing Each module has four compressors with two separate units, one shell and tube evaporator for four systems low pressure cylinder B Unit 2 4-Way valve B 2-1/2" Compressor B Fan A Fan B EXV Water flow direction Capillary Dry type evaporator Condenser Capillary EXV Compressor A 4-Way valve A low pressure cylinder A Unit 1 34

34 MCAC-ATSM Air-cooled modular chiller unit 50Hz KW module refrigeration system sketch drawing Each module has six compressors with three separate units, one shell and tube evaporator for six systems. low pressure cylinder B Unit 2 4-Way valve B 3" Compressor B Fan A Fan B EXV Water flow direction Capillary Dry type evaporator Condenser Capillary EXV Compressor A 4-Way valve A Unit 3 low pressure cylinder A Unit KW module refrigeration system sketch drawing Each module has eight compressors with two separate units, one shell and tube evaporator for four systems low pressure cylinder B Unit 2 Compressor B2 4-Way valve B 4" Compressor B1 Fan A Fan B EXV Water flow direction Capillary Dry type evaporator Compressor A2 Capillary Condenser EXV Compressor A1 4-Way valve A low pressure cylinder A Unit 1 35

35 Air-cooled modular chiller unit 50Hz 6. Piping diagram MCAC-ATSM /30KW module water pipeline sketch drawing The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Stop valve Y-shaped filter Pressure gauge Thermometer Water flow switch Circulating pump Gate valve Check valve Flexible joint Automatic discharge valve 36

36 MCAC-ATSM KW module water pipeline sketch drawing Air-cooled modular chiller unit 50Hz auto-air exchanse valve Fan coil unit Fan coil unit 2-way valve Water pump Expansion tank Y-shaped filiter Water-flow valve Water replenishing valve 1.5kg<Water replenishing pres<6kg Flexible joint 2-way valve Fan coil unit Double -pipe heat exchanger Safety valve Flexible joint Flexible joint Cutoff valve Flexible joint Fan coil unit Aux. heater Thermometer Manometer This figure for reference purpose only, please in terms of the design rule for field installation. The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Safety valve Y-shaped filter Pressure gauge Thermometer Water flow switch Water pump Cut off valve Expansion tank Manometer Water replenishing valve 37

37 Air-cooled modular chiller unit 50Hz /60/65kw&(65kw digital) module water pipeline sketch drawing MCAC-ATSM DN100 The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Stop valve Y-shaped filter Pressure gauge Thermometer Water flow switch Circulating pump Gate valve Check valve Flexible joint Automatic discharge valve 38

38 MCAC-ATSM KW module water pipeline sketch drawing Air-cooled modular chiller unit 50Hz The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Stop valve Y-shaped filter Pressure gauge Thermometer Water flow switch Circulating pump Gate valve Check valve Flexible joint Automatic discharge valve 39

39 Air-cooled modular chiller unit 50Hz KW module water pipeline sketch drawing MCAC-ATSM The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Stop valve Y-shaped filter Pressure gauge Thermometer Water flow switch Circulating pump Gate valve Check valve Flexible joint Automatic discharge valve 40

40 MCAC-ATSM KW module water pipeline sketch drawing Air-cooled modular chiller unit 50Hz Expansion tank Main unit Water replenishing Dirt discharge valve Differential pressure by-pass valve Drain valve Two-way valve Terminal Auxiliary electric heater Three-way valve The table below describes the symbols. Symbol Symbol explanation Symbol Symbol explanation Stop valve Y-shaped filter Pressure gauge Thermometer Water flow switch Circulating pump Gate valve Check valve Flexible joint Automatic discharge valve 41

41 Air-cooled modular chiller unit 50Hz MCAC-ATSM Wire Diagrams 7.1 Chiller wiring diagram 25/30KW module Attached Drawing (I) Electric Drawing of Main Unit and Auxiliary Unit 42

42 MCAC-ATSM Air-cooled modular chiller unit 50Hz 30KW new module (Only for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) CN5 PUMP HEAT_A RE D A1 A2 BLACK WHIT E T2(V) T1(U) RE D 2 WHITE 3 4 COMP A BL UE AC CONTACTOR T3(W) T3B T3A PWM(B) BLACK XS7 XS8 XP7 XP8 PWM(A) CONDENSER TEMP B CONDENSER T E MP A WH ITE CN4 L1 L2 L3 L4 CN6 CN7 CN8 ON/OFF CN2() PMV(B) CN1(WHIT E) PMV(A) CN10 CN22 CN21 CN26 CN14 T3A T3B T4 CN19(WHI TE) TRANS OUT TRANS CN5 H&L_PRO CHECK CN18(WHITE) POWER BLACK WHITE CN25 COM(O) S1 CN6 COM(I) HEAT PUMP CN24 (YELLOW) CN11(BLA CK) FAN_A CN30 FAN_B CN31 PWM CN17 P1 P2 W1 W2 AL A RM H1 H2 P Q (E) HEAT_B A1 A2 BLACK WHITE T2(V) T1(U) COMP B T3(W) AC CONTACTOR XT7 BLACK BLACK BLACK PURPLE XT5 BLACK XS9 XP9 T4 CURR ENT(A2) CURRENT BOARD YELLOW CURRENT( B2) K1(A) H_PRO(A) TEMP PROTECTOR SWITCH A HIGH PRESSURE PROTECTOR A ORANGE K1(B) H_PRO(B) TEMP PROTECTOR SWITCH B HIGH PRESSURE PROTECTOR B MAIN BOARD CN15 5V LOW PRESSURE PROTECTOR 1A L_PRO(1A) PURPLE L_PRO(1B) LOW PRESSURE PROTECTOR 1B S7 S8 S9 OFF SW3 ON ON S2 S3 S4 S5 OFF SW2 L_PRO(2B) L_PRO(2A) PURPLE () () 11-WAY TERMINAL XT2 P Q E ON /OF F 2-WAY TERMINAL XT3 CO M NC OFF OFF OFF OFF FLOW PROVI DE PROVI DE S2 S 3 S4 S5 S7 S8 S9 S2 S 3 S4 S5 S7 S8 S9 SWTICH BY USER BY USER HEA T FLOW (E FFEC T O N NO. 0 MO DUL E) REMO TE FUCTI ON SETTING (ON/OFF SIGNAL!) ON OFF ON OFF ON OFF (ON/OFF SIGNAL!) S7 ON/OFF LOW VOLTAGE SIGNAL DON'T CONNECT HIGH VOLTAGE! BLACK BLACK CN2 T3A2 COLD MODULE LO W CN1 FAN CAP RELAY BROWN WHITE HIGH Y&G BLACK KM1 RELAY YE LLO W A1 A2 BLACK RE D 2 WH ITE 3 4 BL UE 5 6 V U PUMP Y&G AC CONTACTOR ORANGE BL ACK PWM PRESSURE RELIF VALVE XT6 BLACK Y&G BL ACK XT4 W GRAY YELLOW ORANGE PURPLE 16-WA Y DA IL S WITC H FU NCTI ON S1 DAIL SWIT CH A DDRE SS MIDDLE WIRE JOINT MIDDLE WIRE JOINT MIDDLE WIRE JOINT S.V(A) 4-VALVE A G RAY BLACK BLACK YELLOW BROWN GRAY SW2/ SW3 FUCT ION DEFIN ATION S2 ON:COOL ONLY OFF :R&C S3 ON:DIGIT AL OFF :FIXED S4 ON:H-EEP ROM OFF :NORMAL S5 ON:C-EEP ROM OFF :NORMAL S7 ON:REMOT E CONTROL OFF:WIR E CONTROL S8 ON:LOW T EMP.MODE OFF:NOR MAL S9 ON:30KW OFF:65/ 130/200/ 260KW 4-WAY TERMINAL XT1 DEFA ULT SETT ING ON SW2 DIGI TAL FIXED SW3 SW2 ON ON SW3 ON REMO TE COOL REMO TE HEAT REMO TE TURN OFF POWER IN BROWN WHIT E CRANK Y&G COMPRESSOR A CRANK Y&G COMPR E SSO R B BLACK MARK:NOR MAL MODULE S DON 'T INCL UDE BROKEN LINE AND THEIR JOINT WIRES OUTDOOR WIRING DIAGRAM MIDDLE WIRE JOINT (NO)(COM) (NC) TOTAL OUT-LET WATER TEMP IN-LET WATER TEMP SENSOR UNIT OUT-LET WATER TEMP ANTI-FREEZING TEMP SENSOR BLACK BLACK S.V(A) 4-VALVE B WHITE BLACK Attached picture (I) Electric Drawing of Main Unit and Auxiliary Unit BLACK POWER PROTECTOR 43

43 Air-cooled modular chiller unit 50Hz 55/60/65KW module MCAC-ATSM Attached picture (I) Electric Drawing of Main Unit and Auxiliary Unit 44

44 MCAC-ATSM KW digital module(only for MGB-D65W/RN1) Air-cooled modular chiller unit 50Hz Y&G Y&G 4-WAY TERMINAL XT1 CRANK Attached picture (I) Electric Drawing of Main Unit and Auxiliary Unit HEAT_A1 WHITE BLACK A1 A2 WHITE T2 T1 (U) (V) Y&G COMP A1 (W) T3 COMPRESSOR A1 AC CONTACTOR ORANGE ORANGE WHITE BLACK A1 A2 WHITE T2 T1 (U) (V) Y&G COMP B 21 AC CONTACTOR 22 ORANGE (W) T3 COMPRESSOR B BROWN Y&G HIGH BLACK FAN B CONDENSER CONDENSER TEMP A TEMP B BLACK WHITE MIDDLE BLACK WIRE JOINT XT7 MIDDLE WIRE JOINT MIDDLE PURPLE WIRE JOINT S.V(A) S.V(B) 4-VALVE A 4-VALVE B XT5 XT T3B T3A T4 XS8 XS7 XS9 XP9 XP8 XP7 ANTI-FREEZING TEMP. SENSOR RT4 IN-LET WATER TEMP. SENSOR UNIT OUT-LET WATER TEMP. TOTAL OUT-LET WATER TEMP. RT5 RT6 RT7 ELECTRIC EXPANSIVE VALVE(B) CN6 CN27 CN10 CN22 CN21 CN26 CN14 CN32 CN33 CN34 CN35 PMV(B) ICOMP-B2 T3A T3B T4 ICOMP-A1 ICOMP-B1 ICOMP-A2 COM(I) COM(O) CN11() POWER OUT CN5 CN6 CN7 CN8 L4 L3 L2 L1 CURRENT BOARD CN4 PWM PRESSURE RELIF VALVE L1 L2 L3 CRANK HEAT_A2 BROWN WHITE BLACK A1 A2 WHITE T2 T1 (U) (V) Y&G COMP A2 (W) T3 COMPRESSOR A2 AC CONTACTOR ORANGE HEAT_B CRANK BLACK FAN A Y&G BROWN HIGH LOW WHITE BLACK BROWN WHITE BROWN OUTDOOR WIRING DIAGRAM QUERY S1 CN23(WHITE) ON/OFF PMV(A) CN28() HEAT/COOL CN19(WHITE) TRANS OUT MAIN BOARD CURRENT(A2) CN2() PMV(B) CURRENT(A1) YELLOW BLACK CN1(WHIITE) PMV(A) H_PRO(A) HIGH PRESSURE PROTECTOR A ORANGE K1(A1) TEMP PROTECTOR SWITCH A1 K1(A2) TEMP PROTECTOR SWITCH A2 WHITE CN18(WHITE) POWER SW3 ON SW2 ON K1(B) H_PRO(B) TEMP PROTECTOR HIGH PRESSURE SWITCH B1 PROTECTOR B L_PRO(1A) CURRENT(B1) S2 S3 S4 S5 S7 S8 S9 CN5 H&L_PRO PURPLE LOW PRESSURE PROTECTOR 1A CN20() TRANS IN L_PRO(1B) FANB CN31 FANA CN30 CN3(YELLOW) PH_PRO LOW PRESSURE PROTECTOR 1B CN4() WATER_PRO L_PRO(2A) PWM CN17 COMP.B2 COMP.A2 COMP.B1 S.V(B) COMP.A1 S.V(A) CN9(WHITE) CN12(BLACK) CN15(WHITE) PUMP CN24 (YELLOW) HEAT CN7 () CN8(WHITE) ANTI-FREEZING ALARM CN16 PURPLE LOW PRESSURE PROTECTOR 2A 16-WAY DAIL SWITCH FUNCTION S1 DAIL SWITCH ADDRESS () L_PRO(2B) LOW PRESSURE PROTECTOR 2B PURPLE ORANGE BROWN YELLOW YELLOW SW2/SW3 FUCTION DEFINATION S7 ON:REMOTE CONTROL OFF:WIRE CONTROL S8 ON:LOW TEMP.MODE OFF:NORMAL S9 ON:30KW OFF:65/130/200/260KW S2 ON:COOL ONLY OFF:R&C S3 ON:DIGITAL OFF:FIXED S4 ON:H-EEPROM OFF:NORMAL S5 ON:C-EEPROM OFF:NORMAL DEFAULT SETTING SW2 SW3 ON ON OFF OFF S7 S8 S9 S2 S3 S4 S5 REMOTE FUCTION SETTING REMOTE TURN OFF REMOTE HEAT REMOTE COOL OFF ON ON OFF ON OFF GRAY S7 WHITE YELLOW YELLOW BLACK BROWN GRAY GRAY BLACK YELLOW ON/OFF 4-WAY TERMINAL XT4 H2 P1 P2 H1 W1 W2 P Q (E) BLACK WHITE P Q (E) 7-WAY TERMINAL XT2 PROVIDE BY USER PROVIDE BY USER HEAT PUMP (EFFECT ON NO.0 MODULE) POWER IN (ON/OFF SIGNAL!) (ON/OFF SIGNAL!) LOW VOLTAGE SIGNAL DON'T CONNECT HIGH VOLTAGE! 45

45 Air-cooled modular chiller unit 50Hz 130KW module MCAC-ATSM Attached picture (I) Electric Drawing of Main Unit and Auxiliary Unit 46

46 MCAC-ATSM KW module Air-cooled modular chiller unit 50Hz T4-3 T4-2 Attached Drawing (I) Electric Drawing of Main Unit and Auxiliary Unit T4-1 TRANS1 CAP1 CAP2 X T3 P Q (E ) XT2 A B C A B C A B C A B C TRANS2 A B C TRANS3 A B C 50Hz A ~ B C KM6 KM5 KM4 KM3 KM2 KM1 N V 3N U V W Y /G U V W U V W U V W U V W U V Y /G Y /G Y /G Y /G W Y /G COMP1A COMP1B COMP2A COMP2B COMP3A COMP3B Heat1B Heat1A Heat2A Heat3A Heat2B Heat3B 47

47 Air-cooled modular chiller unit 50Hz 250KW module MCAC-ATSM Attached Drawing (I) Electric Drawing of Main Unit and Auxiliary Unit 48

48 MCAC-ATSM Air-cooled modular chiller unit 50Hz 7.2 Networking communication schematic of main unit and auxiliary unit 25/30KW module 49

49 Air-cooled modular chiller unit 50Hz 30KW new module(only for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) MCAC-ATSM Attached picture (II) Networking Communication Schematic of Main Unit and Auxiliary Unit H1 H2 P1 P2 RVV-300/500 4*10+1*6mm The length of wire shouldbeshorter than 500m 100Ω Yellow Gray Black Fault Query Notes The wiring diagramof auxiliary heater and pump is just for reference,please follow the instructions of corresponding auxiliary heater products. Please choose such accessoryaspower wire, switch of auxiliary heater according to the actual parameter ofproductsandnational A B C N 120Ω H1 H2 P1 P2 H1 H2 P1 P2 RVV-300/500 4*10+1*6m RVV-300/500 4*10+1*6mm 50

50 MCAC-ATSM /60/65KW module Air-cooled modular chiller unit 50Hz 51

51 Air-cooled modular chiller unit 50Hz MCAC-ATSM KW digital Mmodule(Only for MGB-D65W/RN1) Attached picture (II) Networking Communication Schematic of Main Unit and Auxiliary Unit H1 H2 P1 P2 The length of wire should be shorter than 500m 100Ω Yellow Gray Black Fault Query Notes The wiring diagram of auxiliary heater and pump is just for reference,please follow the instructions of corresponding auxiliary heater products. Please choose such accessory as power wire, switch of auxiliary heater according to the actual parameter of products and national A B C N 120Ω H1 H2 P1 P2 H1 H2 P1 P2 52

52 MCAC-ATSM KW module Air-cooled modular chiller unit 50Hz 53

53 Air-cooled modular chiller unit 50Hz 200KW module MCAC-ATSM Attached Drawing (II) Networking Communication Schematic of Main Unit and Auxiliary Unit Gra Y ellow y Black Fault Query Power Supply Connector 54

54 MCAC-ATSM KW module Air-cooled modular chiller unit 50Hz Attached Drawing (II) Networking Communication Schematic of Main Unit and Auxiliary Unit H1 H2 P1 P2 The length of wire should be shorter than 500m Yellow Gray Black Notes The wiring diagram of auxiliary heater and pump is just for reference,please follow the instructions of corresponding auxiliary 120Ω heater products. Please choose such accessory as power wire, switch of auxiliary heater according to the actual parameter of products and national A B C N H1 H2 P1 P2 H1 H2 P1 P2 55

55 Air-cooled modular chiller unit 50Hz MCAC-ATSM Electric Characteristics Model Outdoor Unit Power Supply Compressor OFM Hz Voltage Min. Max. TOCA MFA LRA RLA KW FLA MGB-F25W/RN ( 2) 9.1( 2) MGB-D25W/RN ( 2) 9.1( 2) MGB-F30W/RN ( 2) 9.1( 2) MGB-D30W/RN ( 2) 9.1( 2) MGCSL-F30W/RN ( 2) 11.8( 2) MGCSL-D30W/RN ( 2) 11.8( 2) MGB-F55W/RN ( 2) 17.6 ( 2) 0.65( 2) 3.0( 2) MGB-F60W/RN ( 2) 17.6( 2) 0.65( 2) 3.0( 2) MGB-F65W/RN ( 2) 17.6 ( 2) 0.65( 2) 3.0( 2) MGB-D65W/RN /74/ /9.1/ ( 2) 4.5( 2) MGB-F130W/RN ( 4) 17.6 ( 4) 0.88( 4) 4.0( 4) MGB-F200W/RN ( 6) 17.6 ( 6) 0.88( 6) 4.0( 6) MGBT-F250W/RN ( 8) 20.8( 8) 5.6( 8) 14.4( 8) Remark: TOCA: Total Over-current Amps. (A) MFA: Max. Fuse Amps. (A) LRA: Locked Rotor Amps. (A) RLA: Rated Locked Amps. (A) OFM: Outdoor Fan Motor. KW: Rated Motor Input (KW) FLA: Full Load Amps. 56

56 Air-cooled modular chiller unit 50Hz MCAC-ATSM Capacity Tables 9.1 MGB-F(D)25W/RN1 Cooling: Chilled water outlet temp. Ambient temp.( ) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) KW KW KW KW KW KW KW KW KW KW KW KW

57 MCAC-ATSM Air-cooled modular chiller unit 50Hz Heating: Hot water outlet temp. Ambient temp.( ) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) KW KW KW KW KW KW KW KW KW KW KW KW KW KW

58 Air-cooled modular chiller unit 50Hz MCAC-ATSM MGB-F(D)30W/RN1 Cooling: Chilled water outlet temp. Ambient temp.( ) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) KW KW KW KW KW KW KW KW KW KW KW KW

59 MCAC-ATSM Air-cooled modular chiller unit 50Hz Heating: Hot water outlet temp. Ambient temp.( ) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) KW KW KW KW KW KW KW KW KW KW KW KW KW KW

60 Air-cooled modular chiller unit 50Hz MCAC-ATSM MGB-F55W/RN1 Cooling: Chilled water outlet temp. Ambient temp.( ) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) Kw kw Kw kw Kw kw Kw kw Kw kw Kw kw

R22 air-cooled modular chiller 50Hz unit. Content

R22 air-cooled modular chiller 50Hz unit. Content Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode R0A (kw-0kw) 0Hz KJR-0B/BE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 Contents Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 The specifications, designs, and information in this book are subject to change without notice for product improvement.

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement. MCAC-ATSM-2014-01 Content R410A Mini Split Chiller 50Hz 1. Model Names of Outdoor Units... 2 2. External Appearance... 2 3. menclature... 3 4. Features... 4 5. Descriptions of Standard Unit... 6 6. Specifications...

More information

60Hz R410A ClimaMaster Tropical Rooftop Package Unit. Content. 1. Models List External Appearance Nomenclature...

60Hz R410A ClimaMaster Tropical Rooftop Package Unit. Content. 1. Models List External Appearance Nomenclature... 0Hz R40A ClimaMaster Tropical Rooftop Package Unit MCAC-RTSM-20-0 Content. Models List... 2. External Appearance.... Nomenclature... 2 4. Feature & Benefit.... List of Function.... Specification... 8 7.

More information

Air / water Heat Pumps with axial fans. Technical Manual MODULAR HPE XM

Air / water Heat Pumps with axial fans. Technical Manual MODULAR HPE XM Air / water Heat Pumps with axial fans HPE XM 35 570 MODULAR Technical Manual HPE XM 35 570 Contents 1. Nomenclature... 4 2. Product Schedule... 4 3. Technical Features... 5 4. Specification... 7 5. Dimensions...

More information

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content MCAC-ATSM-2014-09 Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components... 8 5. Specifications... 10 6. Dimensions... 14 7. Piping Diagram... 15 8.

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control... R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor

More information

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) CL25610 to CL25615 English Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components...

More information

Manual de Instrucciones Rooftop Serie CLIMA CREATOR 50Hz

Manual de Instrucciones Rooftop Serie CLIMA CREATOR 50Hz Manual de Instrucciones Rooftop Serie CLIMA CREATOR Hz Lea atentamente todo este manual antes de utilizar su nuevo equipo de aire acondicionado. Modelos: BSRC _ HWN-R IMPRESO EN PAPEL ECOLÓGICO Contents.

More information

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model

More information

1. Outdoor units lineup

1. Outdoor units lineup Content 1. OUTDOOR UNITS LINEUP... 2 2. NOMENCLATURE... 3 3. FEATURES... 4 4. DESCRIPTION OF MAIN COMPONENTS... 7 5. SPECIFICATIONS... 9 6. DIMENSIONS... 13 7. PIPING DIAGRAM... 14 8. WIRING DIAGRAM...

More information

AIR-COOLED SCROLL MODULAR CHILLER

AIR-COOLED SCROLL MODULAR CHILLER MCC--6 IR-COOLED SCROLL MODULR CILLER R4 (5-5) 5z Coercial ir Conditioner usiness Units Midea ir Conditioning and Refrigeration Sector dd: West region of Midea coercial air conditioner department, Industry

More information

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER BIGGER-H SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional R&D

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

inverter mini chiller

inverter mini chiller inverter mini chiller TRUST AIR CONDITIONING EQUIPMENT CO. Prepared By: Engineering & R & D Department. Shiraz- May 2017 Content 1. OUTDOOR UNITS LINEUP... 2 2. FEATURES... 3 3. DESCRIPTION OF MAIN COMPONENTS...

More information

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Service manual. MIV V4+ Mini

Service manual. MIV V4+ Mini DM12-01.01.05en Service manual MIV V4+ Mini DC INVERTER R410A (~220V, 50Hz, 1Ph) MVUH80A-VA1 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 6 Part 3 Installation... 44 DM12-01.01.05en

More information

Ceiling & Floor type Unit

Ceiling & Floor type Unit Ceiling & Floor type Unit Part 1. Product Features Quietest operation, low noise. Thin design, space-saving. Easy to operate, remote control. 16 Part 2. Specification Model MUA-18HRN2 MUA-24HRN2 MUA-24HRN2

More information

Modular Water Cooled Water Chiller

Modular Water Cooled Water Chiller Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized

More information

[U] Serie MOV. Manual de Ingeniería

[U] Serie MOV. Manual de Ingeniería [U] Serie MOV Uniidades Condensadoras (Fllujjo Verttiicall) 6..3,, 8 y 12..5 Ton Manual de Ingeniería - 112- Outdoor Units_MOV 1. Specifications.... 2. Dimension... 3. Service Space. 4. Piping Diagrams

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series) Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 10 CR A5ACV - 007 Air-Cooled Chiller (R410A Inverter Series) 1. NOMENCLATURE Production spec variation Type of ref. connection

More information

Floor-Standing Type(E Series)

Floor-Standing Type(E Series) Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

DC Inverter Multi-split System Technical Manual - 50Hz/R410a DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/1.0/201111 Content Contents Part 1. General Information... 1 1. Features... 1 2. Nomenclature... 3 3. Products Line-up... 5 4.

More information

MAC-A R410A Series Air cooled Modular Chiller

MAC-A R410A Series Air cooled Modular Chiller Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd. Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller Content Introduction 1 Features...1

More information

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Service Manual.   Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle

More information

Screw Water Cooled Chiller SCW210

Screw Water Cooled Chiller SCW210 Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Engineering Data Book

Engineering Data Book 40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

3 0 H X C A - H P 2

3 0 H X C A - H P 2 3 0 H X C 1 3 0 A - H P 2 Max. Leaving Water Temperature (Heating Mode) 1 for 47 O C,2 for 60 O C Water-to-Water Screw Heat Pump 3 rd Generation Global Water Cooled Chiller Norminal Capacity (USRT) Carrier

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161 Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR Air-Cooled Mini Chiller Manual No: TMA-AMAC-1161 REGISTERED ISO 9002 CONTENTS PAGE 1. NOMENCLATURE SYSTEM...

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw. 1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing

More information

Air Cooled Scroll Chiller / Heat Pump

Air Cooled Scroll Chiller / Heat Pump Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M 1. MODELS LIST 1. NOMENCLATURE 3 3. FEATURES 3 4. PRODUCT DATA 6 5. PERFORMANCE CORRECTION 9 6. ANTIFREEZE 1 7. INSTALLATION 13 8. ELECTRICAL DATA 16 9. ELECTRICAL DIAGRAM 17 10. SCHEMATIC WIRING DIAGRAM

More information

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A Universal Chilling Systems, LLC. 2 Unit Manual Contents 1. Specification 2. Transportation 3. Unit Installation 4. Electrical Installation 5. Commissioning

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL T/R40A/50Hz (GC2004) CONTENTS PRODUCT...2 MODELS LIST...2. Split Type...2.2 Integral Type...3 2 NOMENCLATURE...3. Split Type...3.2 Integral Type...4

More information

Engineering Data Book

Engineering Data Book 40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Air-Cooled Mini Chiller and Heat Pump

Air-Cooled Mini Chiller and Heat Pump Product, Installation and Operation Manual 309 B/C 03/03 A Date: March 2003 Supersedes: none Air-Cooled Mini Chiller and Heat Pump M4AC 080 150 C Cooling capacity from 22,4 to 40,0 M4AC 080 150 CR Cooling

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,

More information

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application 6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A Contents 1. Product Lineup... 1 2. External Appearance... 1 3. Nomenclature... 1 4. Features... 2 5. List of Functions... 3 6. Specifications... 6 7. Dimensional Drawings... 8 8. Wiring Diagrams... 9 9.

More information

Mini unitary chiller. Mini unitary chiller

Mini unitary chiller. Mini unitary chiller Mini unitary chiller Mini unitary chiller Product description Features and benefits Description of main components Specification Operation limits Hydraulic performance Dimension Service space Piping diagram

More information

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 Built-in pumping group Scroll compressor Plate type heat exchanger EER up to 2,88 rcgroup.it Chillers : Motoevaporating units

More information

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz COMMERCIAL AIR CONDITIONERS Aqua Mini Chiller 50/0Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

ERACS.C-N Higher efficiency air-cooled screw pump

ERACS.C-N Higher efficiency air-cooled screw pump ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER GROUND-RH SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

13 SEER CONDENSING UNITS & AIR HANDLERS

13 SEER CONDENSING UNITS & AIR HANDLERS 13 SEER CONDENSING UNITS & AIR HANDLERS (GC201305-I) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CON TECHNICAL SALES GUIDE-60Hz CAPACITY RANGE:11/2~5

More information

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH Outdoor Units - appearance 18,000Btu/h 30,000~36,000Btu/h 24,000Btu/h 48,000Btu/h-60,000Btu/h Model Names of Outdoor Units

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

AIR-COOLED SCROLL MODULAR CHILLER

AIR-COOLED SCROLL MODULAR CHILLER M--6 IR-OOL SROLL MOULR ILLR R4 (5-5) 5z oercial ir onditioner usiness Units Midea ir onditioning and Refrigeration Sector dd: West region of Midea coercial air conditioner department, Industry venue,

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

Engineering Data Book

Engineering Data Book 40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

nemo a hp rcgroupairconditioning R410A

nemo a hp rcgroupairconditioning R410A NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

High COP. Water-Cooled Screw Chiller

High COP. Water-Cooled Screw Chiller High COP Water-Cooled Screw Chiller 3 4-7 9 High COP The units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow. It is distinguished for its chlorine-free

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

Engineering Data Book

Engineering Data Book 40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller. 2. FEATURES TRUE DUAL CIRCUITS BPHE The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information