Installation Instructions Model DLC
|
|
- Amberly Ford
- 6 years ago
- Views:
Transcription
1 Installation Instructions Model DLC Device Loop Card INTRODUCTION OPERATION The SIEMENS Model DLC Device Loop Card is the interface for connection of FireFinder-XLS smoke detectors, manual stations, monitor devices, and control devices to the FireFinder-XLS System. The DLC uses one network address on the system. The application program that is loaded into the on-board microprocessor controls the DLC operation. The DLC contains 12 LEDs for diagnosis of problems. Ground fault detection is provided by loop. All field devices connected to the DLC are addressed and tested using the Device Programming Unit (DPU). The DLC initializes, operates, and maintains all devices residing on the loop. The DLC communicates all relevant device and event information, such as alarms and troubles, to the System CPU. The sensitivity of any intelligent smoke detector and the logic functions of any intelligent output devices can be checked and adjusted from the PMI through the DLC. All information about the devices on the loop can be displayed on the PMI. The DLC allows the System polarity insensitive devices to be connected without generating errors. The DLC supports only one loop (two isolated parallel zones) of up to 252 FireFinder-XLS intelligent field devices as well as device accessories (relay bases, audible bases, and remote lamps) in any combination. The microprocessor controls the on-board isolator to isolate either zone from the loop if one of them is shorted. When one zone is isolated from the loop, the other zone will still work. Z O N E 1 Z O N E 2 DLC RESET POWER CARD FAIL HNET FAIL GND FAULT ALARM TROUBLE ZONES STATUS CLASS A OPEN CLASS A RETURN SHORT CLASS A OPEN CLASS A RETURN SHORT HNET The on-board microprocessor provides the DLC with the ability to function and initiate alarm conditions even if the main FireFinder-XLS CPU fails. Figure 1 DLC Device Loop Card Siemens Building Tec echnologies
2 Controls and Indicators The front panel of the DLC contains one reset switch, 12 LEDs, and one HNET address switch, as shown in Figure 1. A reset switch is located on the top of the front panel. Pushing the reset switch re-initializes the DLC operation. The LEDs follow the reset switch and their functions are defined as follows: POWER (Green) Normally ON. When illuminated, indicates the power for the DLC is applied to the card. CARD FAIL (Yellow) Normally OFF. When illuminated, indicates the card microprocessor has failed. HNET FAIL (Yellow) Normally OFF. When illuminated, indicates that the HNET communication with the DLC has terminated and the card goes into degrade mode. GND FAULT (Yellow) Normally OFF. When illuminated, indicates that the DLC has detected either a negative or positive ground fault on its field wiring. ALARM (Red) Normally OFF. When illuminated, indicates that the DLC has detected an alarm. TROUBLE (Yellow) Normally OFF. When illuminated, indicates that the DLC has detected a trouble on its field wiring. CLASS A OPEN ZONE 1 (Yellow) Normally Off. When illuminated, indicates a Zone 1 wire is open if the loop was set to Class A. CLASS A RETURN ZONE 1 (Yellow) Normally Off. When illuminated, indicates a Zone 1 return wire is reversed if the loop was set to Class A. SHORT ZONE 1 (Yellow) Normally Off. When illuminated, indicates a Zone 1 wire short. CLASS A OPEN ZONE 2 (Yellow) Normally Off. When illuminated, indicates a Zone 2 wire is open if the loop was set to Class A. CLASS A RETURN ZONE 2 (Yellow) Normally Off. When illuminated, indicates a Zone 2 return wire is reversed if the loop was set to Class A. SHORT ZONE 2 (Yellow) Normally Off. When illuminated, indicates a Zone 2 wire short. A three-position switch at the bottom of the front panel is used to set the HNET network address of the DLC. All field devices connected to the DLC are addressed and tested using the Device Programming Unit (DPU). Refer to the DPU Manual, P/N for further information. 2
3 PRE-INSTALLATION Set the three-digit HNET network address for the DLC using the three-position switch located near the bottom of the front panel. (Refer to Figure 1 for the location of the switch.) The address for the DLC must be the same as the address selected for it in the Zeus Programming Tool. To increment each digit of the address, press the + button above the desired digit; to decrement each digit, press the - button below the desired digit. The range of allowable addresses is from 001 to 251. INSTALLATION The DLC plugs perpendicularly into one slot in the CC-5 card-cage via two 96-pin DIN connectors and can occupy any slot in the card cage. (Refer to Figure 2.) Insert the DLC card into the card guides rightside up (lettering on the front panel is legible) Slide the card in until the card edge connectors contact the receptacles on the motherboard. Verify that the DIN connectors of the card and the cardcage aligned properly. The card can only plug in one direction to the card cage, if it does not align, DO NOT FORCE the card. Place thumbs on the front panel adjacent to the captive screws and gently apply even pressure on the card until the connectors seat in the receptacles on the motherboard. Figure 2 Installing The DLC Secure with the captive screws. WIRING Disconnect BATTERY and AC prior to working on equipment. All field wiring to the DLC is connected to the terminal blocks of the CC-5 card cage slot in which it is installed. To Connect External Wiring 1. Lift the WHITE cover on the terminal block. 2. Loosen the screw of the terminal by turning it counterclockwise. 3. Insert the wire into the side of the terminal block. 4. Tighten the screw of the terminal block by turning it clockwise. Connect +24V from the PSC-12 to terminal 17 and -24V from the PSC-12 to terminal 18 of the slot in the CC-5 where the DLC will be installed. (Refer to Figure 3.) 3
4 ZONE 1 ZONE 2 CLASS A WIRING* NO T-TAPPING ALLOWED BOTH ZONES MUST BE WIRED AS CLASS A CLASS B WIRING** T-TAPPING ALLOWED BOTH ZONES MUST BE WIRED AS CLASS B ZONE 1 ZONE 2 ZONE 1 ZONE 2 INITIATING DEVICE INITIATING DEVICE LINE 1 LINE 2 LINE 1 LINE DO NOT USE ONE SLOT OF CC V+ 24V- DO NOT USE TO 24VDC FROM THE PSC-12 Figure 3 Wiring The 24VDC Power Lines To The DLC Slot In The CC-5 CC-5 CC *OPERATES IN FULL CONFORMANCE WITH STYLE **OPERATES IN FULL CONFORMANCE WITH STYLE 4 Figure 4 DLC Wiring Diagram NOTES: 1. NO END OF LINE DEVICE REQUIRED. 2. BOTH CIRCUITS SUPERVISED AND POWER LIMITED PER NEC
5 The DLC circuit can be wired Style 4 (Class B) or Style 6 (Class A). On-board switches controlled by microprocessor allow selection of Class A or B without using jumpers for Class B. The DLC field circuit wiring does not require twisted, shielded wire. It can be installed in conduit containing low voltage power, notification appliance circuits, audible and speaker zone circuits, and RS-485 and other data circuits without restrictions. Electrical connections for the two zones are shown in Figure 4. The wiring style is set in the Zeus Programming Tool without using external jumpers. Once the wiring style is set, both zones will be set to the same style. Do not wire the two zones in different styles. If the return wires are reversed in each zone (Class A), the CLASS A RETURN LED will turn on. Switch the two return wires to remove this trouble. Eliminate all other troubles before completing the installation. COMPATIBILITY 1. The DLC supports only FireFinder-XLS intelligent devices. The compatibility identifiers for the compatible devices are the model numbers listed in Table 1. Use any combination of those listed. TABLE 1 DLC Compatible Devices Compatible Devices AD-11P ADBH-11 AD-HR DB-11 DB-HR HFP-11 HFPT-11 HLIM HMS-2S HMS-M HMS-S HMS-SA HMS-D HTRI-D HTRI-M HTRI-R HTRI-S HZM ILED-HC ILED-HW RL-HC RL-HW Installation Instructions P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N P/N The DLC supports one loop (with 2 isolated zones) of up to 252 FireFinder- XLS intelligent field devices. Up to 252 devices can be distributed in either zone, but the total number is limited. For example, if 100 devices are in Zone 1, then the number of the devices in Zone 2 must be 152 or less. 3. All circuits are power limited to NFPA 70 per NEC 760. The DLC supports the use of 18 AWG min non-shielded, non-twisted, thermoplastic fixture wire without conduit, if permitted by local building codes. 4. No end of line device is required. 5. Total circuit resistance of each zone must not exceed 50 ohms when 252 devices are loaded into one zone. (Refer to the chart on page 6.) Maximum capacitance: 0.5µF between line+ and line- 1.0µF between line and chassis 6. T-tapping is not allowed on Class A loops. ELECTRICAL RATINGS 24V Back Plane Current 0 Screw Terminal 24V Current 100mA + 1.8mA per device 6.2V Back Plane Current 200mA max 24V Standby Current 145mA + 1.8mA per device D evice Loop: 30VDC peak 375mA max (power limited) 5
6 Line Resistance (ohm) Max Number of Devices Per Zone DLC LINE RESISTANCE vs MAX NUMBER OF DEVICES Note: The total number of devices in two zones can not exceed 252. For CE applications in Cerberus E100 systems refer to Installation Instruction A24205-A334-B844 (English) or A24205-A334-A844 (German)., Inc. 8 Fernwood Road Florham Park, New Jersey 07932, Ltd. 2 Kenview Boulevard Brampton, Ontario L6T 5E4 CN Siemens Gebäudesicherheit GmbH & Co. ohg D München
Installation Instructions Model CDC-4
Installation Instructions CDC-4 Conventional Card INTRODUCTION The SIEMENS CDC is a card that allows conventional detectors to be used on the FireFinder-XLS system. It provides four Class or Class B conventional
More informationInstallation Instructions Model HZM
Installation Instructions Model Remote Conventional Zone Module INTRODUCTION The Model from is an intelligent device that connects a single zone of conventional devices to a DLC (FireFinder-XLS System)
More informationInstallation Instructions Model ABHW-4S
Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.
More informationFire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION
Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,
More informationTYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER
Installation Instructions Model AD-HR Air Duct Monitoring Housing INTRODUCTION The SIEMENS Model AD-HR is a sampling tube, air duct monitoring housing. When used with a compatible smoke detector, smoke
More informationInstallation Instructions Model SSD-C-REM
Installation Instructions Model SSD-C-REM Remote System Status Display with Control ON ALARM SUPERVISORY SECURITY TROUBLE AUDIBLES SILENCED INTRODUCTION The SIEMENS Model SSD-C-REM is an optional FireFinder
More informationFire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.
Fire Safety nstallation nstructions Model MMB- Main ontrol Board OPERATON The SEMENS Model MMB- board in each MXL System controls operations and monitors input device identity, network communication, and
More informationIntelligent Detection Devices
Intelligent Detection Devices Multi-Criteria Fire Detector [with ASAtechnology TM ] Advanced multi-criteria fire detector that has dual-optical and thermal sensors Differentiates between deceptive phenomena
More informationFIREFINDER-XLS CONTROL PANEL
FIREFINDER-XLS CONTROL PANEL Installation, Operation and Maintenance Manual P/N 315-033744-3 Siemens Building Tec echnologies Fire Safety CAUTION ALL WIRING MUST BE DONE AS DESCRIBED BELOW TO OBTAIN SAFE
More informationModel PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual
Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview
More informationFIREFINDER-XLS CONTROL PANEL
FIREFINDER-XLS CONTROL PANEL Installation, Operation and Maintenance Manual P/N 315-033744-4 Siemens Building Technologies Fire Safety CAUTION ALL WIRING MUST BE DONE AS DESCRIBED BELOW TO OBTAIN SAFE
More informationModel OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors
Intelligent Detection Devices Multi-Criteria Fire / CO Detector [with ASAtechnology TM ] ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors
More informationFire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11
Fire Safety Installation Instructions Model ADBX11 Audible Base INTRODUCTION Model ADBX11 The SIEMENS Model ADBX11 Audible Base consists of a standard Series 11 base combined with an audible device. All
More informationFire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION
Fire Safety Installation Instructions Model RCC-/R and RSE- Remote Control Centers INTRODUCTI The SIEMENS Model RCC-/R Remote Command Center (See Figure ) provides the option to remotely annunciate and
More informationData Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906
s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones
More informationFire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W
Fire Safety Installation Instructions Model NIM-W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION The SIEMENS Model NIM-W provides a new communication path for the following uses:
More informationAddressable NAC Output Module D327A
Installation Instructions Notice Addressable NAC Output Module D327A These instructions cover the installation of the D327A Addressable NAC Output Module in an analog system controlled by a Bosch D8024,
More informationARCHITECT AND ENGINEER SPECIFICATIONS
s Data Sheet Fire Safety Products Intelligent Detection Devices Multi-Criteria Fire / CO Detector [with ASAtechnology TM ] ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that
More informationMultiplex Eight Input Remote Modules
Multiplex Eight Input Remote Modules 1.0 Introduction These instructions cover the installation of the D7042/D7042B Eight Input Remote Modules in a fire system supervised by an FPD-7024 Fire Alarm Control
More informationModels NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117
Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring
More informationMATERIALS AND PROCUREMENT DEPARTMENT 1900 YONGE STREET PAGE 1 OF 1 TORONTO, ONTARIO M4S 1Z2
TORONTO TRANSIT COMMISSION ADDENDUM NO._1_ MATERIALS AND PROCUREMENT DEPARTMENT 1900 YONGE STREET PAGE 1 OF 1 TORONTO, ONTARIO M4S 1Z2 TENDER NO.: T31CD13101 TITLE: SUPPLY AND OFFLOAD FIRE ALARM EQUIPMENT
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationMODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description
MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated
More informationAND ARCHITECT SPECIFICATIONS
MXL-IQ Advanced Life Safety System ENGINEER AND ARCHITECT SPECIFICATIONS FirePrint Application Specific Fire Detection Capacity for up to 240 Intelligent Analog Detectors Expandable Up to a Stand Alone
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationFireSeeker Model FS-250C Addressable Fire Alarm Control Panel
FireSeeker Model FS-250C Addressable Fire Alarm Control Panel One intelligent signaling line circuit (DCLB + DCLA) SureWire Polarity insensitive loop wiring Utilizes S-Series detectors and devices Supports
More informationANNUNCIATOR FIXED MODULE
12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95
More information1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation
More informationANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations
Audio Network Controller Board Installation Instructions Module Mounting Locations The Audio Network Controller board can be mounted in two places. One position is over the Audio Network Controller module
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationFIREFINDER-XLS CONTROL PANEL
FIREFINDER-XLS CONTROL PANEL PMI Operation Manual ALARM SUPERVISORY SECURITY TROUBLE... POWER ON 10:32:05 04/15/01 SYSTEM STATUS: NORMAL AUDIBLES SILENCED FireFinder-XLS Siemens - Fire Safety More Info
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationPrint Specification. Publication. Instructions. Specific requirements. General requirements
Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is
More informationWD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.
Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationCerberus TM PRO Fire Safety System A comprehensive fire-protection system
s Data Sheet Fire Safety & Security Products Cerberus TM PRO Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the
More informationCZ-6A Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS CZ-6A Six Zone Interface Module 658 Kitimat Rd. Unit #6 Mississauga, Ontario L5N T5-800-SENSOR, FAX: 905-8-077 www.systemsensor.ca SPECIFICATIONS Normal Operating
More informationIDP-Zone-6 Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority
More informationAND ARCHITECT SPECIFICATIONS
CSM-4 Controllable Signal/Releasing Module ENGINEER AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices Class A (Style Z) or Class B (StyleY)
More informationInstruction Manual EVA-S6 Base
Instruction Manual EVA-S6 Base Sounder Base NITTAN COMPANY, LIMITED 1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully
More informationSIGA-CC1 Single Input Signal Module Installation Sheet
SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationMR-2602 Two Zone Fire Alarm Control Panel
MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...
More informationSC-6 Six Supervised Control Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:
More informationAdvanced Protection System
MXL-IQ Advanced Protection System FirePrint Application Specific Detection Capacity for up to 240 Intelligent Analog Detectors Expandable Up to a Stand Alone System Capacity of 998 Input and Output Points
More informationThese instructions detail procedures to follow in order to avoid damage to equipment.
D326A, D334A, D339A Point Contact Modules Installation Guide 1.0 Notice These instructions are for the installation of the D326A, D334A and D339A Point Contact Modules in an analog system controlled by
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationD7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector
D700DH EN Installation Instructions Multiplex Photoelectric Duct Smoke Detector D700DH Installation Instructions.0 Description Notices These instructions cover the installation of the D700DH Multiplex
More informationD285DH. Installation Instructions Photoelectric Duct Smoke Detector
D85DH EN Installation Instructions Photoelectric Duct Smoke Detector D85DH Installation Instructions.0 Introduction FCC Notice The D85DH Photoelectric Duct Smoke Detector complies with Part 5 of the Federal
More informationDesigo TM Fire Safety System A comprehensive fire-protection system
s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2)
More informationSystem Accessories, LCD Annunciators
System Accessories, LCD Annunciators UL, ULC Approved* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Fig 1: A4606-9202 LCD Annunciator with Red Trim Fig
More information/5121/5122 TrueAlert Power Supply Installation Instructions
4100-5120/5121/5122 TrueAlert Power Supply Installation Instructions Introduction This publication provides an overview of the features, specifications, and capabilities of the TrueAlert power supplies
More information4100U City and Relay Cards Installation Instructions
4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting
More informationRF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors
RF80THS EN Installation Instructions Wireless (RF) Photoelectric Smoke Detectors RF80THS Installation Instructions Trademarks Trademarks Chamber Check is a registered trademark of Bosch Security Systems
More informationFigure 1. Figure 2. See notes 1 and 2 below.
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.
More informationOperating Instructions MXL Multi-Line Keyboard/Display Panel
Operating Instructions MXL Multi-Line Keyboard/Display Panel Local Mode Operation TRODUCTION When the MXL Keyboard/Display Panel is installed in a control panel, the components are behind a locked door.
More informationInstallation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator
Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator INTRODUCTION The Model MDACT from Siemens Industry, Inc. is a multipoint serial dialer for use in MXL and
More informationMS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels
R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:
More informationSupplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual
Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Replace the following pages of Document Number 50734 (I56-993-01/D770-19-00), Revision B with the corresponding revised
More informationConventional Releasing Control Panel
s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:
More informationFA-101U Fire Alarm Control Panel
FA-101U Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the
More informationFireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual
Fire Safety FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview
More informationFMR Installation Instructions. Addressable Fire System Controller
FMR-7033 EN Installation Instructions Addressable Fire System Controller EN 2 FMR-7033 Installation Instructions Contents Contents Contents...2 1.0 Introduction...3 2.0 Description...3 3.0 Device Mounting...3
More informationFire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module
Fire Safety Installation Instructions Model Fiber Optic Interface INTRODUCTION The Model from Siemens uilding Technologies, Inc. (See Figure 1) is a Fiber Optic interface for the MXL s RS-485 network (MNET
More informationInstallation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev
Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control
More informationOSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM
OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp
More informationLDM Series Lamp Driver Modules For Graphic Annunciation and Control
12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and
More informationFireFinder XLSV Digital Emergency Voice Alarm / Communication System
s Data Sheet Fire Safety Products FireFinder XLSV Digital Emergency Voice Alarm / Communication System ARCHITECT AND ENGINEER SPECIFICATIONS Eight (8) digital audio channels Compatible with Model PMI-3
More informationAFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION
968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationLifeAlarm Fire Alarm Control Panels
LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient
More informationInstallation Instructions Models FDBZ492, FDBZ492-R and FDBZ492-HR
Installation Instructions Models FDBZ492, FDBZ492R and FDBZ492HR Air Duct Monitoring Housings INTRODUCTION Models FDBZ492, FDBZ492R and FDBZ492HR from, are air duct monitoring housings containing sampling
More informationFX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual
Advanced Life Safety Solutions Advanced Life Safety Solutions FX-2000 Intelligent Analog Fire Alarm Control Panel Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: 905-660-4655 Fax: 905-660-4113 U.S.A.
More informationMANUAL RESET ALARM RELEASE
Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationCautions and Warnings. Introduction 4009 NAC POWER EXTENDER
Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately
More informationInstruction Manual EVA-STB-RL
Instruction Manual EVA-STB-RL Relay Base NITTAN COMPANY, LIMITED -54-5 SASAZUKA, SHIBUYA-KU, TOKYO 5-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully and keep
More information30.45 Electric Release PDRP-2001
The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationAND ARCHITECT SPECIFICATIONS
SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification
More informationDETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS
TEST LOG Detector Identification Information Manufacturer and Serial Date Detector Model: Number: Installed: Description of Detector Location: Test Results and Maintenance Data Date Test Test Maintenance
More informationThe ACM-8R Annunciator Control Module
12 Clintonville Road Northford, CT 06472 203-484-7161 FAX: 203-484-7118 The Annunciator Control Module For the System 500, System 5000, AFP-200, AM2020, AFP1010 and SFP-1024 Fire Alarm Control Panels Document
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationInstallation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger
Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger
More informationD326A/D334A/D339A. Installation Instructions. Point Contact Modules
D326A/D334A/D339A EN Installation Instructions Point Contact Modules D326A/D334A/D339A Installation Instructions 1.0 Description Notice Use these instructions to install the D326A, D334A, and D339A Point
More informationINTELLIGENT FIRE ALARM CONTROL PANEL
INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements
More informationFor a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.
Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight
More informationControl Relay Modules
TM INTERNATIONAL ANALOG ADDRESSABLE INPUT/OUTPUT DEVICES Control Relay Modules Model SIGA-CR, SIGA-MCR, SIGA-CRR, Features! Provides one no/nc contact (SIGA-CR/MCR) Form C dry relay contact can be used
More information9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE
Cerberus PRO Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE Cerberus PRO Fire Safety Products ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Cerberus PRO 252-point
More informationDS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector
DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable
More informationCerberus PRO A comprehensive fire-protection system
Cerberus PRO A comprehensive fire-protection system Cerberus TM ARCHITECT AND ENGINEER SPECIFICATIONS Standard 252-point and 504-point fire systems Remote viewing for the 252- point and 504-point systems
More informationMANUAL RESET ALARM RELEASE BOX
MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual
More informationMMF Six Zone Interface Module
Installation and Maintenance Instructions I56-900-005 MMF-0-6 Six Zone Interface Module SPECIFICATIONS Normal Operating Voltage: 5- VDC Stand-By Current: ma Alarm Current: 40 ma (assumes all six LEDs solid
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationAir Duct Housings. Description
Air Duct Housings Series IL, and Series 3 Ionization or Photoelectric Detectors Optional Relays for Supplementary Equipment Operation Optional Control Module for Self-contained Operation (Series 3 Detectors
More informationSubmittal Transmittal, Consultant
Submittal Transmittal, Consultant (D) Grouped by Each Number Due Date: Boeing 4-20 VPAL - VPAL Construction Project # 4212054-007 Tel: Fax: Skanska USA Building Inc. Date: 2/21/2014 Reference Number: 0086
More information