1 त र य क य ऱय / R e g i o n a l o f f i c e 46, ई.स.र ड, आई.ड.ए.ट वर / 46,E.C.Road,IDA Tower, 1 st फ ऱ र, न कट द व रक स ट र / 1 st Floor, Near Dwarka Store द हर द / Dehradun उत तर ख ड / Uttrakhand द रभ ष/Telephone: ,04,05 फ क सष/Fax: ( स रक ष कक ष / SECURITY CELL ) Ref. No.10/RODDN/SEC/2018/HS/S-02 दद क / Date: Empanelment of Venders for Supply/Installation& AMC of Security & Fire Safety Gadget for branches under RO:Dehradun for and Applications are invited from reputed agencies for empanelment of Security Vendors for Supply/Installation / AMC of Security & Fire Related Equipments/Gadgets of various categories for branches/atms of our Bank in under RO Dehradun. The jurisdiction of RO Dehradun includes all districts of Uttarakhand state and 04 districts of Uttar Pradesh (Bijnor, Muzaffarnagar, Shamli, Saharanpur). NO DESCRIPTION OF STORES / SERVICES I. Empanelment of Security Vendors for Supply/Installation / AMC of Security & Fire safety Related Equipments/Gadgets for Branches/ ATMs/ Administrative Offices under RO: Dehradun). The details of Category / Item or System / Equipments are as under. CATEGORY SUPPLY&INSTALLATION OF SECURITY GADGETS a. SECURITY ALARM SYSTEM b. DVR BASED CCTV SYSTEM c. STAND ALONE BURGLAR ALARM SYSTEM FOR ATMS. d. ACCESS CONTROL SYSTEM e. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM CATEGORY - AMC f. AMC OF ABOVE ITEMS (a to e) CATEGORY - FIRE EXTINGUISHERS g. SUPPLY / REFILLING OF FIRE EXTINGUISHERS i. Modular Fire Extinguishers ii. Portable Fire Extinguishers 1
2 II AIM OF EMPANELMENT: To create and have a pool of readily available Security Vendors capable of supplying the required system, equipment / components, or services of the laid down specifications, at competitive rate without loss of time and are also able to provide the after sales service for at least 5-8 years to ensure all time serviceability thereby prolonging the life of the security equipment. II. a Empanelment will be for two separate groups i. Empanelment for Supply / AMC of Security Equipments: -Services specified in items (a) to (e) of Para, I i.e CATEGORY SUPPLY&INSTALLATION OF SECURITY GADGETS a. SECURITY ALARM SYSTEM b. DVR BASED CCTV SYSTEM c. STAND ALONE BURGLAR ALARM SYSTEM FOR ATMS. d. ACCESS CONTROL SYSTEM e. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM CATEGORY - AMC f. AMC OF ABOVE ITEMS (a to e) ii. Empanelment for Supply & Installation of Fire Related Equipments/Gadgets (FEs):- Services specified in item (g) of Para I, i.e CATEGORY - FIRE EXTINGUISHERS g. SUPPLY / REFILLING OF FIRE EXTINGUISHERS i.modular Fire Extinguishers ii.portable Fire Extinguishers iii. Bids/Offers shall be submitted as per above classification / grouping. i.e The bidder may submit the Bid for x. Empanelment for Supply / AMC of Security Eqpts: -Services specified in items (a) to (f) of Para I 2 or
3 y. Empanelment for Supply & Installation of Fire Related Equipments/Gadgets (FEs):- Services specified in item (g) of Para I z. For both Empanelment as shown in x & y or iv. If bids are not submitted as per above classification / grouping, it will be considered as incomplete bids and will be rejected. v. Bids if submitted for individual item/items other than specified in above grouping shall not be entertained. 2. Interested Venders /suppliers available/ operating in the area within the stipulated time should send their information as follows : a) Introductory letter as per APPENDIX- A along with documentary proof. b) Documents as mentioned in PQC (Pre-Qualification Criteria) at Para IV duly attested with sign and seal of authorized signatory. 3. Venders /suppliers should ensure that their Security gadgets are as per the Technical specifications / Data mentioned in APPENDIX- B. 4. Our officer/s shall visit the premises /office / manufacturing facility of each firm/vender and verify the documents forwarded with the originals held by firms / suppliers. 5. The firms /suppliers will be rated as per procedure existing in our Bank. 6. Venders / Suppliers who fulfill the laid down criteria shall be requested to give demonstration of the equipment before the empanelment committee so as to ascertain the suitability and its conformity with laid down Technical specifications. The committee shall shortlist the suppliers accordingly. 7. Firms / Suppliers/Venders selected will be requested to submit the sealed quotations for each equipment to submit their financial bids in sealed covers. 8. Financial bids submitted by the short listed firms shall be opened by the empowered committee as per the laid down procedure to ascertain the market rates. The rates will also be standardized at our end in order to ensure common minimum rates for each equipment / accessories. 9. Efforts will be made to empanel minimum of 3-5 venders. 10. The details should reach our Office at above mentioned address latest by 24 January 2018 by PM positively. GENERAL TERMS & CONDITIONS II. a. incomplete offers, offers not confirming fully to the requirements specified in this letter or with vague 3
4 replies will not be considered. b. Any conditional bids/applications shall not be considered and will be out rightly rejected in the very first instance. III. Definitions: The definitions in this Letter to be understood subject to exceptions. a) Security Vendor: The word Security Vendor means any original manufacturer / authorized Supplier or Dealer or AMC provider of any of the Security & Safety or Fire related equipment, who will be submitting their offer /bid. b) Equipment: The word equipment means any System/ Gadget/Components used for installing in the branches / offices etc for the purpose of Security, surveillance & Fire Safety etc. c) Items: The items shall be the equipments shown in Para 1(i) from a to g including its subcategories unless specified different. IV. PRE-QUALIFICATION CRITERIA a. Qualification criteria given below specify minimum Qualification criteria in various areas to ensure that Security Vendor / his partner has necessary experience, expertise, financial strength and skilled human resource to provide quality service to the Bank. b. Documents are not transferable. c. Provide documentary details wherever necessary. d. Following are the mandatory requirements (Details of documentary proof required is specified in brackets/ Italics) 1. Turnover should be over and above Rs 25 Lakhs per year during last 3 years. (Audited Balance Sheet for (FY; , & ) 2. Should have a presence & continuous experience in the market from the past 5 years with experience in offering similar solutions. (Copies of work orders & value of work done) 3. Should be a registered firm a. (Company Registration Certificate, MoA & Board Resolution authorizing authority to Authorised Signatory;) b. Partership Partnership deed and PoA authorizing authority to Authorised Signatory. c. Proprietorship - letter of Proprietorship, ID Proof and Address Proof of Proprietor.) 4. Should be registered with authorities of GST(Copy of certificate) 5. Should have valid PAN Card(Copy of PAN) a. Should be financially strong to undertake such kind of projects and should furnish (Bank Solvency Certificate of minimum Rs. 5 Lakhs to establish the financial soundness of the Company. (The Solvency Certificate shall be the latest i.e Not issued before 01/06/2017 ) 6. Should be empanelled for similar services with PSBs / PSUs/Central/State Govt. undertaking in Uttarakhand & UP. (Copies of work orders & Value of work done) 7. Should have effective infrastructure /workshop for undertaking repair of equipments in the area of service required. (Proof of having the facility Any legal document with certificate issued by Govt. authority, lease deed etc which is in force). 8. Should must be an income tax assesses and should have filed IT return for the last three Assessment Year.(ITR Acknowledgement for FY; , & ) 4
5 e. Additional requirements, which may give weightage to the bidder in the evaluation process 1. ISO or other relevant Certifications 2. OEM certification exclusively in the name of Security Vendor, specifying maintenance support. V. SERVICES FROM SECURITY VENDOR EMPANELMENT & SUPPORT a. The Bank reserves the right for selection and finalization of empanelment as per laid on procedures. The Security Vendors will be considered for empanelment only if it meets all conditions specified in this letter and screening being done by the Bank. b. Empanelment would be done for a period of 02 years from the date of finalization of the process / approved date. The extension of empanelment for 02 more years may be done after carrying out the yearly review by the Bank with regards to the performance & services of Security Vendors. Technical as well as other Specification of various Items of all Categories shall be as specified in Appendix B (These are the minimum specification required). Fresh Installation / New Equipment (items a-e) c. After successful empanelment of Security Vendors, during the event of a new installation of any system, either for a branch or for an independent ATM, the requirements of the individual items may vary case to case and Quotation will be obtained from the empanelled Sec Vendors in sealed envelopes and supply order will be given to the (L1) for supply/installation. d. On the basis of costs specified above, the firm who stands L1 shall be awarded the project for that particular case, which will not only reduce the time frame for installation but also gives a transparent system of awarding the project. e. Rates for passive components like wire & conduits shall not be taken in the price comparison as the payment of those items will be made on actual only. Applicable taxes will also be extra. f. Installation of each item shall be completed within 10 days of release of order which will be intimated to the registered id of the Security Vendor. In case of delay, due to any genuine cause, Security Vendor may submit representation to RO within 4 days of issue of the order for approval. RO reserves the right to accept the representation of not based on merit. AMC of items (item f) g. After successful empanelment of Sec Vendors, AMC Quote will be asked for Annual AMC rate from the empanelled Security Vendors in sealed envelope which will be scrutinized and rate of AMC will be finalized by the Bank after taking account of Market value as well as related aspects. Security Vendors who accepts the rate finalized by the Bank will be awarded with AMC of various Branches. The Bank will take all possible steps to distribute Branches evenly to all qualified Security Vendors, however, RO shall also consider factors like equal opportunities, level of service and other aspects which are is in the interest of the Bank in addition to the price factor, and shall reserves the right of awarding the job in each case. The region has the jurisdiction of whole Uttarakhand and 04 districts of Uttar Pradesh. The sec vendor must have to accept the A.M.C of districts of UP branches/atms along with main land. h. This rate once accepted will be valid till completion of the empanelment. i. In the case of additional installation / augmentation of equipments in an existing location, the work may be awarded to the Security Vendor who is already providing AMC support for said category for that Office, so that the compatibility and continuity in the support can be ensured, however, rates will be that of approved rate chart. 5
6 j. Items under warranty:- Equipments already under warranty shall not be included in the AMC charges. However, if the warranty expires during the currency of the AMC period, the cost of the equipment may also be included on pro-rata basis for calculating AMC charges from the date of expiry of warranty. Scope and Coverage of the AMC: The contract will be for a period of two years During the visit the technician should check the systems thoroughly from all the points, regarding its functioning and maintenance. Date of servicing shall be noted on the control panel. Service technician should make an entry in the alarm register at the branch mentioning the date of servicing, repairs carried out, battery/ cells replaced. Service technician should be in possession of valid Identity Card with photograph. In case of any modification in the system or change of wiring or any major work, including running wires through conduit etc, is suggested by the technician, an estimate of the expenditure involved to be submitted to the Branch. The servicing shall be carried out once in a quarter without fail and the period between mandatory services shall not be less than 70 days & more than 90 days. If any repair work is to be carried out, prior permission should be sought from controlling office. The Service Charges exclude the cost of components required to be replaced. In case the Security/Fire/CCTV systems is replaced with a new system and is under warranty, the AMC would be applicable only after expiry of the warranty period. All the staff members are to be made familiar with the operation, location of switches and maintenance of alarm system. If the system is beyond in-situ repairs, a standby system will be provided by the agency and the unit so taken will be installed back duly repaired. Major repairs involving heavy expenditure will be done only after being approved by this office. Replacement of system will be recommended only if the system is beyond economic repairs. k. Site response time: The AMC Security Vendor shall turn up for attending the problem within a time period of 24 hours from the time of registering of the complaint, failing which may attract penalty. This would not include bank holidays l. Turn-around time: The AMC Security Vendor shall repair / replace/ provide solution within a time period of 48 hours from the time of registering of the complaint. This would not include bank holidays. In case the equipment could not be brought into working conditions within the time specified above, the Security Vendor shall provide a substitute so that the working of the system should continue, failing which may attract penalty. m. Preventive Maintenance visit by AMC Security Vendor (mandatory visit once in a quarter even if the branch has not called):- At least one mandatory preventive Maintenance visit shall be arranged by AMC provider once in each quarter even if there is no complaint from the branch. Details of the visit shall be recorded in the equipment register and a copy in detail shall be forwarded to RO. n. Procedure for On Call Visits, whenever required by branches to attend any complaint or 6
7 General: repairs: - The branch will be making the telephone calls to register the complaint (on telephone number of the AMC provider or by , fax or letter). While registering the complaint, a complaint number shall be generated, by service provider, with date and time and inform branch as well as Security Cell RO. Likely time of deputing the technician shall be informed to the branch by the Security Vendor. The branch shall make note of the complaint number (With date and time) in the security equipment checking register. When the technician from the AMC provider visits the branch / repairs the system, he shall make entry against the complaint in the register with details of the defects, its rectification as well as present status. The Officer in charge of the branch shall endorse his remarks against rectification of each and every complaint. Maintenance / Repair log for each equipment shall be recorded and shall be kept updated in the register. Branch officials to ensure that the system is working fine before giving the sign off. o. Service Report: The repairs shall be carried out at the branch itself (on site). In case the equipment is required to be taken to the workshop for repairs, the replacement / stand by system shall be provided by the AMC provider. Service report shall be duly completed after the closure of the complaint which shall be signed by the technician and officer in charge. First copy shall be handed over to the Branch. Second copy shall be sent to RO security cell on weekly basis by the Security Vendor. Third copy may be retained by the AMC provider as record. Consolidated summary of branch visits shall be sent once in a quarter to Security Cell / RO; eg first week of July, October, January and April. This shall include details of both Preventive Maintenance visits as well as On call visits. p. FE Fresh Installation / Re-filling.(item-g) Aspects specified in Para V d-f & Para V j,k will be followed in the case of fresh installation. q. In the case of re-filling, the Security Vendors who becomes L1 based on refilling charges of FEs for a particular branch as specified in the approved rate list will be awarded with Re-filling job. r. RO will be considering factors like equal opportunities, level of service and other aspects which are is in the interest of the Bank in addition to the price factor, and shall reserves the right of awarding the job in each case for each category. s. RO shall be intimating the minimum requirements of equipments in a standardized manner and the Security Vendor shall ensure installation of the same within three months in all Branches under AMC. No deviation in this shall be accepted. If found any deviation after completion of a quarter, penalty clause shall be invoked. VI. OTHER CONDITIONS a. All entries in the Bids form should be legible and filled clearly. b. If the space for furnishing information is insufficient, a separate sheet duly signed by the authorized signatory may be attached. 7
8 c. No overwriting or cutting is permitted. However, the cuttings, if any, in the Letter / Application must be initialed by the person authorized to sign the bids. d. No costs incurred by the applicant in applying, in providing necessary clarifications or attending discussions, conferences or site visits will be reimbursed by the Bank. e. If the application is made by a partnership firm, it shall be signed by all the partners of the firm with their full names and current addresses, or by a partner holding the power of attorney for the firm for signing the application, in which case a certified copy of the power of attorney shall accompany the application. A certified copy of the partnership deed, current address of the firm and the full names and current addresses of all the partners of the firm shall also accompany the application. f. If the application is made by a limited company, it shall be signed by a duly authorized person holding the power of attorney for signing the application in which case a certified copy of the power of attorney shall accompany the application. The information furnished must be sufficient to show that the applicant is capable in all respects to successfully complete the envisaged work in respective category. Attested Board Resolution in this regard can also be attached in place of PoA. g. The evaluation will be based on the experience of the agencies and their financial capabilities and may also include inspecting the works carried out by the agency for which necessary coordination shall be made by the agencies. Based on the details furnished and inspection of works, eligibility criteria, the agency shall be empanelled. Decision of the Bank regarding selection / rejection for empanelment will be final and binding and no further correspondence will be entertained. The empanelled agencies will only be informed by post / . h. If, information and details furnished by applicants are found to be false at any time in future or any information withheld, which comes to the notice of the Bank at a later date, the empanelment of such applicant will be cancelled immediately. i. Bank reserves its right to reject any / or all the applications without assigning any reasons whatsoever. j. The Bank will not be responsible for the Bids received late on account of any reason. Authorized Signatory 8
9 APPENDIX- A To, The Asstt. General Manager, Security Cell Syndicate Bank, Regional office, 46, E.C Road, IDA Tower Dwarka Store Dehradun Dear Sir, Sub: Application for empanelment of Security & Fire Safety Gadgets. 1. Refer to your advertisement appeared in. dated I / we hereby forward our application for empanelment of Security & Fire Safety gadgets in your bank / RO as per the given Performa. I / We also hereby declare that the information furnished in the application and in the supplementary sheets from pages....to.are correct to the best of my / our knowledge and belief. Signature Name Designation Address Place: Date: Seal of Applicant: 1. Name of the Organization. : 2. Address. : 9
10 3. Year of Establishment : 4. Status of Firm : (Whether Company/ Firm/ Proprietary) (Enclose relevant document /deed) 5. Name of the Directors/Partners/Proprietor. : i) ii) iii) ( Enclose relevant document / deed) 6. Whether registered with the Registrar of companies / : Registrar of Firms. If so mention number and date. 7. a) Name & Address of the Bankers. i) ii) iii) iv) b) Enclose the Solvency certificate from the Bankers : ( Give details) c) Whether able to furnish performance guarantee for : full cost of work if entrusted. 8. Whether registered for sales tax purpose if so mention : number & date. Also furnish copies of sales Tax clearance certificate. 9. Whether an assessment of Income Tax. If so, mention permanent account number. Furnish copies of income tax clearance certificate. 10. Furnish copies of audited balance sheet & profit & loss Account audited) For the last 3 years. 11. If you are registered in the panel of other organizations/ statutory bodies such as CPWD, PWD, MES, Banks etc. Furnish their names and date of registration. i) ii) 10
11 iii) iv) 12. What is your field of activities? Mention the fields on preference basis: i) ii) iii) iv) v) vi) 13. Whether willing to work anywhere in India or mention : The place where you are willing to work. 14. i) Detailed description and value of work done for others in the past: ii) Detailed description and value of work done for the Bank: 15. Specify the maximum value of work executed in a year. 16. Furnish the names of three responsible persons who will be in a position to certify about the quality as well as past performance of your organization. i) ii) iii) Note: Where copies are required to be furnished, these are to be certified copies preferably by the concerned agencies or a Govt Office 11
12 Proforma 1 Particulars in respect of work executed. SI. No. Name of work project with address Short description of work executed Name & address of owner Value of work executed Stipulated time of completion Actual time of completion Name & address of Architect consulting engineer. Proforma 2 Key Personnel Permanently employed. SI. No. Name Designation Qualification Experience Years with the firm Any other
13 Proforma 3 Other relevant Information I. Work Force Permanently employed No. Any other Years with Firm a) Executives b) Managers c) Technicians d) Others II. Workshop Facilities Location Land Area Type of Structure Type of facilities a) b) 13
14 Appendix-B SPECIFICATION AND QUALITATIVE REQUIREMENTS OF SECURITY AND FIRE SAFETY EQUIPMENTS (No Conditional acceptance / Compliance will be entertained) I.Security Alarm System for Branch/Office/attached ATMs Depending upon the ambience and technical feasibility, the security alarm system can be wireless operating within the permissible frequency bands or wired system as may be decided by us. The system shall have following broad specifications: S Tech Specifications / Requirements Complied / No Not Complied 1. The Control Panel should operate on V mains supply via step-down transformer. Zone indicator facility for 4-10 switches with provisions to extend the same as per requirement with display on the control panel shall be available. 2. Control panel/ unit should have Maintenance free automatic re-chargeable 12VDC x l.3-7 AH MF Battery backup. System should automatically change over to battery on power failure and to mains when the power is restored. The Control Panel should be PCB based modular circuitry and have Low Power consumption. 3. The System should have following sensors or should be compatible to provide interface without any additional modifications. Magnetic sensors Passive Infra Red sensors (Min 25 feet range) Model DSC-CL-100 or higher Light detection sensors Auto Dialer Shutter magnetic switch Pressure mats sensors Glass break detector Central Monitoring System (CMS) 4. The System operating frequency should have immunity to external Radio Frequency interference. 5. The following Visual indications on the control panel shall be provided: System on Battery charging Battery Low Battery indication when system under Battery backup. Indications on tamper condition of external speaker, wire or Control panel. Night mode functional indicator Day mode functional indicator Each of channels to be provided 14
15 6. Compatible for provision of Night mode functional indicator at the entrance. 7. Built-in speaker in control unit (25 Watt). 8. Unit body fabrication to be of combination minimum 18 SWG and 14 SWG, with no screws accessible from outside including mounting screws. Front cover to be lockable and designed to be wall-mounted. Corrosion-proof steel metallic body having tamper-proof locking arrangements. 9. Automatic faulty zone/switch isolation should be available in the control panel. 10. Key and lock for ON and OFF function of the system and also for unit locking should be provided. 11. Automatic shut off of alarm after a preset time. Also the siren should be switched off by turning the key switch to armed position. 12. Entry and Exit Delay (adjustable). The Exit/entry time duration should be indicated by the buzzing of the buzzer. 13. Audio-visual testing facility of Alarm System without activating the main speaker should be available (Test button and indication). 14. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to the Alarm System due to high/low voltage, surge/fluctuation. 15. Full tamper-proof circuit, wiring and system. On tampering of any part, the siren should sound. 16. ISI approved wiring and 1 inch ISI marked white PVC conduit. All wiring should be concealed in conduit. 17. External wiring: For panic switch: - Super annealed solid copper wire 0.5 mm diameter insulated to withstand minimum 1100V. For speakers: twin 25 strand copper wire of minimum 36 SWG twisted, flexible and insulated. 18. Operating temperature: -10 C to +55 C. Humidity: 10% to 90% non-condensing. Vibration, Tremors and normally applied jerks resistant. 19. Immunity to static lightning. Minimum 40 Watt (main) external speaker. 20. System should have warranty for minimum one year. 21. Control panel should have lockable strong metal case and it should be installed in a place away from customer service area in a concealed manner. 22. All cabling should in concealed manner 23. The Auto Dialer shall have the following basic features: Minimum 08 telephone numbers feeding facility Able to feed minimum 16 Digit telephone number (each) Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory). 24. Training to be provided to selected branch personnel / guard of the Branch / Office to operate the system 25. The Security Alarm System should be subjected to Performance test and certified by Regional Electronics Test Laboratory or Electronics Test and Development Centre (ET & DC) of Ministry of Information Technology, Govt. of India. 26. Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated. 27. Self-Test facility 28. Power connectivity shall be from UPS 29. Sensors, switches and other accessories should be tamper proof and should be installed in sufficient height where ever required 30. In attached ATMs; Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated. 15
16 31. Panic button inside the ATM room shall be placed in the center of white acrylic board with inscription in red as shown below. Emergency Call (Panic Switch) Police 100 II. SPECIFICATIONS/ FEATURES FOR DVR BASED CCTV SYSTEM ETC. The DVR shall of REPUTED MAKE LIKE- SAMSUNG, BOSCH, DEDICATED MICROS (UK), HIKVISION, DAHUA, Make for all types of Camera - Reputed Make Like Samsung, Bosch, Dedicated Micros (Uk), Hikvision, Dahua, etc which are (CE/FCC certified). S Tech Specifications / Requirements Complied / No Not Complied 1. Digital Video Recorder(DVR) 04/08/16 channel stand alone (UL/FCC/CE approved) 2. Stand alone Digital Video Recorder (DVR) 1.5 U, H.264 compression algorithm for standalone DVR 3. Real time Live display with 4/8/16 cameras 720P high definition. 4. Remote and live display for 4/8/16 cameras, fps recording for CIF and D1 (4ClF) function; 6. Live, recording, playback, backup and network and Mobile access, multi/upto 4 Hard Disc drives (HDDs) and DVD-RW supported, all channels simultaneous playback. 7. Multiple control methods; front panel, IR remote controller, USB mouse, network keyboard Smart video detection: motion detection, camera blank, video loss. 8. Smart camera settings privacy masking, camera lock, color setting and title display. 9. Pan Tilt Zoom and Speed Dome Control; multi protocols supported, preset, scan, auto pan, auto tour, pattern, auxiliary function supported channels and audio inputs- bidirectional talk supported. 11. Back-up methods: USB devices, DVD-RW and network download. 12. Alarm triggers screen tips; boozer, PTZ movement supporting, and FTP upload. 13. Smart HDD management: non working HDD hibernation faulty alarm, 14. multi DVR client CMS network access for remote viewing, recording, playback, setting, system status event log, and FTP Function (UL CEFCC certified). 15. Multi password protection. 16. Maximum record rate upto 50 pps(pal), 17. Built in Activity/Motion detection, 18. Schedule recording, 10/100 base T network interface capability, 19. Virtual Keyboard 20. HDD capacity to accommodate 90 days recording for Branches / ATMs and 180 days for CC. 21. Dual Stream facility (masking of some cameras), 22. Powerful network software: Remote viewing with PC connectivity, built-in web server, multi-dvr client & CMS. Network access for remote live viewing, recording, 16
17 playback setting, system, status, event log, & FTP function (UL / CE/ FCC certified). 23. Monitor Minimum 19 TFT/ Flat screen/lcd, CE/FCC certified (Samsung/ LG/ Sony) Make. Cameras: 24. DOME Make-(Sony/Samsung/ Dahua) (CE/FCC certified) a. Sensor-1/3 Sony chip super HAD CCD with 3.6mm lens with 12 V regulated power supply. b. Video Processing DSP c. Effective Pixels -752(H) x 582(V) d. Sensitivity 0.7 lux for usable picture(40% video) with IRE AGC on e. Resolution- 700 TVL f. Video output- 1.0 Vpp, 75 ohm unbalanced g. S/N ratio 50 db h. White balance- ATW i. AGC Yes j. Gamma Correction DOME (IRLED/ Night Camera)- Make-( (Sony/Samsung/Dahua)) CE/FCC certified. a. Sensor 1/3 Sony chip Super HAD CCD with 3.6mm lens with 12V regulated Power supply. b. Video Processing DSP c. Effective Pixels -752(H) x 582(V) d. Sensitivity 0.7 lux for usable picture(40% video) with IRE AGC on e. Resolution- 700 TVL f. Video output- 1.0 Vpp, 75 ohm unbalanced g. S/N ratio 50 db h. White balance- ATW i. AGC Yes j. Gamma correction C Mount make ((Sony/Samsung/Dahua)) CE/FCC certified. a. Sensor 1/3 Sony chip Super HAD CCD with 3.6mm lens with 12V regulated Power supply. b. Video Processing DSP c. Effective Pixels -752(H) x 582(V) d. Sensitivity 0.7 lux for usable picture (40% video) with IRE AGC on e. Resolution- 700 TVL f. Video output- 1.0 Vpp, 75 ohm unbalanced g. S/N ratio 50 db h. White balance- ATW i. AGC Yes j. Gamma correction Bullet Body IR camera make (Sony/Samsung/Dahua) CE/FCC certified a. 750 TVL, b. Minimum luminance less than 1.0 Lux (F2.0), c. S/N Ratio More than 48dB, d. Internal Sync System, e. Aesthetic design, f. Automatic electronic shutter system, 17
18 g. Low Light Surveillance Support h. Automatic Gain Control, i. Mounting Bracket Included j. Compact Design 28. Pin Hole camera make (Sony/Samsung/Dahua) CE/FCC certified a. Pick Up Device - 1/3" Pixim DPS Sensor b. Horizontal Resolution TVL c. View Angle (Horizontal) - Min 66º d. Dynamic Range - Typical: 102dB / Max: 120dB ( Off / Standard / High ) e. Min. Illumination 0.8 Lux / F1.2 f. Electronic Shutter Control - Built-in g. Back Light Compensation On / Off selectable h. S/N Ratio More than 50dB ( AGC off ) i. White Balance j. Video Output k. Auto Gain Control l. Noise Reduction Auto m. Protective Housing Metal Cabinet 29. Cable RG 6 / RG 59 multi core coaxial cable for connecting cameras to the DVR & for connecting the power supply to the cameras of reputed branch/make. Other CCTV system requirements: 30. Required latest Software (licensed) for complete system. System & software warranty of 12 months from the date of installation/commissioning. 31. Inbuilt Motion Detection Device In tandem with CCTV cameras, of reputed brand/make days recording facility. 33. All Cabling should in concealed manner. 34. Any electrical wiring that may be required for specifications & of reputed brand/ make (ISI marked). 35. Able to provide facility to preview, record & play back the events at a time and should be highly secure & temper proof and easy to trace. 36. Easy system to playback / copy the recording into CD or Pen Drive without disruption of the recording process. 37. Redundant power supply to the CCTV system 38. System should have warranty for minimum one year. 39. Cameras to be placed to cover all access points /parking area /outer periphery of the premises, other activity area inside the bank and other vulnerable points of the branch / ATM in addition to strong room /safe room and cash handling area of the branch. 40. CCTV System should have Night/Low Light Intensity Mode facility and automatic change-over to the same. 41. Control Panel/ DVR System/monitor should be placed so that it is not visible for general public 42. The system should be compatible/ able to configurative multiple cameras which should be above to capture real-time video images & provided video output to view & record the events. 43. Training to be provided to selected branch personnel / guard to operate the system 44. Vandal proof facility should be available for all camera meant for ATMs. 45. Metal covering / Housing for pin hole camera / DVR for ATM should be included. 18
19 46. Camera Mount should be included. 47. Audio interface card should be included in Camera 48. DVR system should be able to perform the following functions: Display the images in the monitor Record the events & store in the hard disc Provide replay of the events(smart search) Event recording through Motion Detection, scheduling, alarms trigger & continuous recording & time lapse modes. Multiple password authorization for high degree of security. Event logging for video loss, motion detection, power on/off, user login etc. 49. Software requirements: Browsing mode Multi/single channel. Camera images outputs in digital format to be displaced as single/multiple channels on monitor screen. Video Recording Mode Manual/ continuous / scheduled/ event based Record digital images on local hard disc via manual selection or continuously (24x7) or scheduled for day & time or if motion is detected. Video play back at variable speed Image compression Latest digital compression technique. Multi level password protection Motion sensitivity levels Motion detection III. ACCESS CONTROL SYSTEM The proximity card based access control system for designated entrances that are in use at present shall have following basic technical specifications: S Tech Specifications / Requirements Complied / No Not Complied 1. Work in two-factor identifications (Proximity Card and PIN) 2. Single Door Controller model with built in Reader, built-in key board. 3. Electromagnetic lock with fail-safe holding force of minimum 600lb (300kg). 4. Regulated Power Supply 12 V, 500 MA. 5. Four Digit PIN number. 6. Exit Push Button. 7. Proximity Cards. 8. Preferably, the controller shall have compatibility with Window based software for In and out record data memory of up to 2000 records. Support the Alarm System with various functions such as distressed alarm, night/ day alarm. Group Management. 9. The basic feature of Biometric (finger print) access control system: Finger print capacity of
20 Should be capable of integrated with computer and Soft/Hard copy of all the entry data can be generated. Electromagnetic lock 600 lb capacity IV. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM (AFDAS) All fully computerized Branches (TBM), CBS Branches and IT Cells should be installed with Automatic Fire Detection and Alarm System (AFDAS). S Tech Specifications / Requirements Complied / No Not Complied 1. AFDAS should be selected, maintained and installed in terms of guidelines laid down in Indian Standard:2189:1988. Should have been certified by the Regional Electronic Test & Development Centre, Dept of Electronics, Govt of India for fulfilling technical specifications given as per IS: Electrical installation pertaining to the entire Fire Alarm System should be independent of other systems. Standby power supply like battery supply with automatic changeover or UPS should be available and must be capable of maintaining the system in normal operation for a period of not less than 48 hours after the failure of main power supply. 3. The recommended scale of installation in TBM branches/ EDP centres is as follows: Type Area Smoke Detector Units (ionization type) Smoke Detector Units At the rate of one unit per area of 15'x15' or fraction thereof equally distributed in the cabins where computer servers/ UPS are located In general areas at the rate of one unit per area of 20'x20' where PCs are kept in general work area of the branch/ office. 4. A minimum distance of 1.5 Meter should be maintained between air diffusers (if centralized air conditioning is provided) and detector point. 5. Detectors should not be mounted within 500 mm from walls or partitions or any obstruction. In case of minor obstruction like light fitting, a clearance of 250 mm should be maintained. 6. A mimic panel or drawing which has a plan of floor reduced to scale to identify the zone of fire should be provided near alarm control panel. 7. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to the Alarm System due to high/low voltage, surge/fluctuation. 8. Manual Call Points (MCPs) should be fixed at a height of 1.4 meter from the floor level. Such MCPs should preferably be located near the entry to the stair case/ door. 9. Two Zones control panel (with the facility for incorporating auto dialer) will be sufficient for normal size CBS Branches. The Zones may be increased depending upon the size of the CBS/ Offices. Incorporation of Auto dialers in the AFDAS is a mandatory requirement. The telephone numbers of Branch Head, Dy Branch Manager, other staff, Fire Brigade and local Police Station may be programmed into the Auto dialer. 10. Control Panel should have Specification as below (should also comply points specified in 4(i) to 4(ix): 20
21 a) Operation on 230 V AC supply with solid state electronic circuitry with built in electronic hooter. b) Visual Zone indicators. c) Audio alarm device incorporating the acknowledge indicators for Fire Condition, Fault Condition, AC Battery Failure indicators, Low Battery indicators, Blown Fuse indicators, AC pilot indicators, Open and short circuit fault, Push buttons to disable audio alarm/ testing each zone, reset and acknowledge reset and test device should be provided. d) Modular design using electric plug-in printed circuit board. e) 2 Zone control panel with 7 AH, 2x12 Volt DC Battery back-up and Battery Rechargeable system (needed by an average sized branch). f) Panel fabricated from mild steel (MS) Sheet with front acrylic sheet door with built in Buzzer. Provided with Main operating controls such as isolation, test, fault, AC failure, Battery Charger indicator and voltmeter. g) The Auto Dialer shall have the following basic features: Minimum 08 telephone numbers feeding facility Able to feed minimum 16 Digit telephone number (each) Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory). 11. Detectors: Ionization Smoke detector Apollo make Series 65 Optical Smoke detector -do- Heat detector -do- 12. Cable: Two core 1.5 sq mm PVC insulated armored copper conductor cable ISI:1554 (Part I): 1998 marked. 13. Other Accessories Electronic hooter complete with diaphragm type speaker of 6 watts. Remote Response Indicator (RI). Manual Call Point (MCP) button (pill box) with Mild Steel Body. V. Integrated Fire & Security Alarm System for ATMs Depending upon the ambience and technical feasibility, the security alarm system can be wireless operating within the permissible frequency bands or wired system as may be decided by us. The system shall have following broad specifications: S Tech Specifications / Requirements No 1. The Control Panel should operate on V mains supply via step-down transformer. Zone indicator facility for 4-10 switches with provisions to extend the same as per requirement with display on the control panel shall be available. 2. IC based control circuitry only, containing relay switch 12 V, capacitor minimum 3 numbers transistors and resistors with Diode (12 numbers) Complied / Not Complied 21
22 3. The control unit should cater for future requirements such as GSM, CMS etc. 4. Control panel/ unit should have Maintenance free automatic re-chargeable 12VDC x l.3-7 AH MF Battery backup. System should automatically change over to battery on power failure and to mains when the power is restored. The Control Panel should be PCB based modular circuitry and have Low Power consumption. 5. The System should have following sensors or should be compatible to provide interface without any additional modifications. Magnetic sensors Passive Infra Red sensors (Min 25 feet range) Model DSC-CL-100 or higher Light detection sensors Auto Dialer Shutter magnetic switch Pressure mats sensors Glass break detector Central Monitoring System (CMS) Smoke detection Fire detection 6. The System operating frequency should have immunity to external Radio Frequency interference. 7. The following Visual indications on the control panel shall be provided: System on Battery charging Battery Low Battery indication when system under Battery backup. Indications on tamper condition of external speaker, wire or Control panel. Night mode functional indicator Day mode functional indicator Each of channels to be provided 8. Compatible for provision of Night mode functional indicator at the entrance. 9. Built-in speaker in control unit (25 Watt). 10. Unit body fabrication to be of combination minimum 18 SWG and 14 SWG, with no screws accessible from outside including mounting screws. Front cover to be lockable and designed to be wall-mounted. Corrosion-proof steel metallic body having tamper-proof locking arrangements. 11. Automatic faulty zone/switch isolation should be available in the control panel. 12. Key and lock for ON and OFF function of the system and also for unit locking should be provided. 13. Automatic shut off of alarm after a preset time. Also the siren should be switched off by turning the key switch to armed position. 14. Entry and Exit Delay (adjustable). The Exit/entry time duration should be indicated by the buzzing of the buzzer. 15. Audio-visual testing facility of Alarm System without activating the main speaker should be available (Test button and indication). 16. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to 22
23 the Alarm System due to high/low voltage, surge/fluctuation. 17. Full tamper-proof circuit, wiring and system. On tampering of any part, the siren should sound. 18. ISI approved wiring and 1 inch ISI marked white PVC conduit. All wiring should be concealed in conduit. 19. External wiring: For panic switch: - Super annealed solid copper wire 0.5 mm diameter insulated to withstand minimum 1100V. For speakers: twin 25 strand copper wire of minimum 36 SWG twisted, flexible and insulated. 20. Operating temperature: -10 C to +55 C. Humidity: 10% to 90% non-condensing. Vibration, Tremors and normally applied jerks resistant. 21. Immunity to static lightning. Minimum 40 Watt (main) external speaker. 22. System should have warranty for minimum one year. 23. Control panel should be housed in lockable strong metal case of 22 gauge metal box and should be installed in the UPS Box of ATM Room away from customer service area. 24. All cabling should in concealed manner 25. The Auto Dialer shall have the following basic features: 26. Minimum 08 telephone numbers feeding facility 27. Able to feed minimum 16 Digit telephone number (each) 28. Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory). 29. Training to be provided to selected branch personnel / guard to operate the system 30. The Security Alarm System should be subjected to Performance test and certified by Regional Electronics Test Laboratory or Electronics Test and Development Centre (ET & DC) of Ministry of Information Technology, Govt. of India. 31. Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated. 32. Panic button inside the ATM room shall be placed in the center of white acrylic board with inscription in red as shown below. Emergency Call (Panic Switch) Police Time with 5 minute auto cut. Reset the switch to cut off the hooter & rest the circuit. 34. Self-Test facility 35. General aspects of Alarm specified in Para I shall be undertaken 36. Power connectivity shall be from UPS 23
24 VI. SPECIFICATIONS/ FEATURES FOR DVR BASED CCTV SYSTEM The DVR (ATM Specific with in-built Monitor) shall of REPUTED MAKE LIKE- SAMSUNG, BOSCH, DEDICATED MICROS (UK), HIKVISION, DAHUA, ETC. S Tech Specifications / Requirements No 1. Stand alone Digital Video Recorder (DVR) 1.5 U, H.264 compression algorithm for standalone DVR 2. In built Monitor (5.56 Inch) 3. Real time Live display ; 720P high definition. 4. Remote and live display, fps recording for CIF and D1 (4ClF) function; 6. Live, recording, playback, backup and network and Mobile access, multi/upto 2 Hard Disc drives (HDDs) and DVD-RW supported, all channels simultaneous playback. 7. Multiple control methods; front panel, IR remote controller, USB mouse, network keyboard Smart video detection: motion detection, camera blank, video loss. 8. Smart camera settings privacy masking, camera lock, color setting and title display. 9. Pan Tilt Zoom and Speed Dome Control; multi protocols supported, preset, scan, auto pan, auto tour, pattern, auxiliary function supported channels and audio inputs- bidirectional talk supported. 11. Back-up methods: USB devices, DVD-RW and network download. 12. Alarm triggers screen tips; boozer, PTZ movement supporting, and FTP upload. 13. Smart HDD management: non working HDD hibernation faulty alarm, 14. multi DVR client CMS network access for remote viewing, recording, playback, setting, system status event log, and FTP Function (UL CEFCC certified). 15. Multi password protection. 16. Maximum record rate upto 50 pps(pal), 17. Built in Activity/Motion detection, 18. Schedule recording, 10/100 base T network interface capability, 19. Virtual Keyboard 20. HDD capacity to accommodate 90 days recording for Branches / ATMs and 180 days for CC. 21. Dual Stream facility (masking of some cameras), 22. Powerful network software: Remote viewing with PC connectivity, built-in web server, multi-dvr client & CMS. Network access for remote live viewing, recording, playback setting, system, status, event log, & FTP function (UL / CE/ FCC certified). 23. Cable RG 6 / RG 59 multi core coaxial cable for connecting cameras to the DVR & for connecting the power supply to the cameras of reputed branch/make. Other CCTV system requirements: 24. Required latest Software (licensed) for complete system. System & software warranty of 12 months from the date of installation/commissioning. Complied / Not Complied 24
25 25. Inbuilt Motion Detection Device In tandem with CCTV cameras, of reputed brand/make days recording facility. 27. All Cabling should in concealed manner. 28. Any electrical wiring that may be required for specifications & of reputed brand/ make (ISI marked). 29. Able to provide facility to preview, record & play back the events at a time and should be highly secure & temper proof and easy to trace. 30. Easy system to playback / copy the recording into CD or Pen Drive without disruption of the recording process. 31. Redundant power supply to the CCTV system 32. System should have warranty for minimum one year. 33. Cameras to be placed to cover all access points /parking area /outer periphery of the premises, other activity area inside the bank and other vulnerable points of the branch / ATM in addition to strong room /safe room and cash handling area of the branch. 34. CCTV System should have Night/Low Light Intensity Mode facility and automatic change-over to the same. 35. Control Panel/ DVR System/monitor should be placed so that it is not visible for general public 36. The system should be compatible/ able to configurative multiple cameras which should be above to capture real-time video images & provided video output to view & record the events. 37. Training to be provided to selected branch personnel / guard to operate the system 38. Vandal proof facility should be available for all camera meant for ATMs. 39. Metal covering / Housing for pin hole camera / DVR for ATM should be included. 40. Camera Mount should be included. 41. General aspects of CCTV System specified in Para II shall be undertaken 42. The DVR shall be kept in UPS Box in case of ATM away from the Branch. If ATM is adjacent to the Branch, DVR may be kept inside the Branch and the wiring to the Camera may be in concealed manner. 43. Power shall be from UPS 44. Audio interface card should be included in Camera 45. DVR system should be able to perform the following functions: 46. Display the images in the monitor 47. Record the events & store in the hard disc 48. Provide replay of the events(smart search) 49. Event recording through Motion Detection, scheduling, alarms trigger & continuous recording & time lapse modes. 50. Multiple password authorization for high degree of security. 51. Event logging for video loss, motion detection, power on/off, user login etc. Software requirements: 52. Browsing mode Multi/single channel. Camera images outputs in digital format to be displaced as single/multiple channels on monitor screen. 53. Video Recording Mode Manual/ continuous / scheduled/ event based Record digital images on local hard disc via manual selection or continuously 25
इ ड यन ओव रस ज ब क Indian Overseas Bank. क ष त र य क य ऱय, Regional Office, Chandigarh
इ ड यन ओव रस ज ब क स रक ष ववभ ग Security Department क ष त र य क य ऱय, Regional Office, Chandigarh TERMS & CONDITIONS FOR ANNUAL MAINTENANCE SERVICE FOR REFILLING OF ALREADY INSTALLED FIRE EXTINGUISHERS
More information{ks=h; dk;kzy; Lkjksftuh gkml 6] Hkxokunkl jksm] ubz fnyyh & Qksu % QSDl % Security Cell
{ks=h; dk;kzy; Lkjksftuh gkml 6] Hkxokunkl jksm] ubz fnyyh & 110001 Qksu % 011-23383916-17 QSDl % 011-23383796 Security Cell Regional Office Sarojini House 6, Bhagwan Dass Road NEW DELHI 110 001 Tel :
More informationEMPANELMENT DOCUMENT NOTICE FOR EMPANELMENT OF SUPPLIERS AND SERVICE PROVIDERS.
PREMISES AND ESTATE SECTION CIRCLE OFFICE, GUWAHATI, 1 ST FLOOR, DWARKAPURI,SONI RAM BORA ROAD, BORA SERVICE, GUWAHATI-781007 Tel Ph: Direct: 0361-2466820 Fax : 0361-2466816 Email Id: pecoguw@canarabank.com
More informationRegional Office: Agra Padam Business Park, Ground Floor, Sector 12 A, Avas Vikas Sikandara Yojna, Agra 282007 Phone: 0562 2600481, Fax: 0562 2600582 E-mail: ro.agra@syndicatebank.co.in -------------------------------------------------------------------------------------------------------------------------------
More informationAppendix - F BANK OF BARODA, GREATER MUMBAI ZONE, MUMBAI PRICE BID TENDER FOR SUPPLY / INSTALLATION OF CCTV SYSTEM. Bill of quantity Price Bid
TENDER FOR SUPPLY / INSTALLATION OF CCTV SYSTEM. Supply of -4- Channel, 00 IPS, 4 Audio in audio Q/P, Digital Video Recorder within inbuilt DVD writer and up to 3 internal Hard Disk Slots, with 3*500 (500
More informationHEAD OFFICE, SECURITY DEPARTMENT
BANK OF INDIA HEAD OFFICE, SECURITY DEPARTMENT RATE TO BE QUOTED BY THE VENDOR Sr. no. Description Make Model Unit Rate Tax Total Amount I BURGLAR ALARM SYSTEM A Burglar/Intruder Alarm System.B Control
More information* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.
Bank of Baroda, MP & Chattisgarh Zone, Bhopal invites sealed Tenders for Supply of New Fire Extinguishers of ISI Mark only & refilling of existing Fire Extinguishers at the Branches in Madhya Pradesh and
More informationBANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE
BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE NAME OF WORK : Supply of New Fire Extinguishers of ISI Mark (As and when required) & refilling of existing Fire Extinguishers at the Branches
More informationPRE-QUALIFICATION OF FIRE SAFETY AUDITORS
STATE BANK OF INDIA LOCAL HEAD OFFICE, BHUBANESWAR PRE-QUALIFICATION OF FIRE SAFETY AUDITORS State Bank of India, Local Head Office, Bhubaneswar invites Expression of Interest (EOI) for conduct of fire
More informationSecurity Solutions From The Masters In Electronic Security Systems
Logitronics Automation India Pvt Ltd Security Solutions From The Masters In Electronic Security Systems Contact Person : Ramaprasad.R Contact Number : 9620135555 E-Mail : {ramaprasad@laipl.com} Innovative
More informationBANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE
BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna 800001. TENDER NOTICE NAME OF WORK : Supply of New Fire Extinguishers of ISI Mark (As and when required) & refilling
More informationNATIONAL BANKING GROUP WEST-1
NATIONAL BANKING GROUP WEST-1 TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONES UNDER NBG WEST-1 BANK OF INDIA BUILDING 2 nd Floor,
More informationSubject: Tender for Comprehensive Annual Maintenance Contract (AMC) for CCTV System
Maharshi Valmiki College of Education (University of Delhi) Geeta Colony, Delhi-110031 MVCOE/AMC-CCTV System/2017/ Dated: 27.03.2017 To Subject: Tender for Comprehensive Annual Maintenance Contract (AMC)
More informationQueries raised by the representatives. 4 Sl. No.( iv) 31 Refer Sl. No. 2 It should be Windows 10 professional as it is the latest one
Corrigendum to the Tender Document pertaining to Supply, Installation, Testing, Commissioning and Maintenance of Network Enabled Access Control System and Visitors Management System of the Head Office
More informationTENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS
TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS Bank of Baroda Zonal Office, Northern Zone, Bank of Baroda Building, 6 th Floor,
More informationUCO BANK INDEX S.N. PARTICULARS PAGE NO. 1 INVITATION FOR TENDER OFFERS INSTRUCTIONS TO BIDDERS AND GENERAL TERMS & CONDITIONS 4-5
UCO BANK Zonal Office,Haryana, G.A.D. Department 1 st Floor Near Old Bus Stand, Karnal-132001 Email-zoHaryana.gad@ucobank.co.in Phone: 0184-4020163 Website http://www.ucobank.com OFFER FOR EMPANELMENT
More informationNotice for Empanelment of Vendors.
NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT, ODISHA REGIONAL OFFICE, 2/1 CIVIC CENTRE, IRC VILLAGE, NAYAPLLI. BHUBANESWAR, ODISHA. Tel-2374305, 2374310, 2374321, E-mail- bhubaneswar@nabard.org
More informationTENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.
TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX. 100 Nos. DIFFERENT BRANCHES IN _BAREILLY,SHAHJAHANPUR,AGRA,HALDWANI & DEHRADUN REGIONS
More informationSupply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder
Software Technology Parks of India - Pune (An Autonomous Society under Govt. of India, Ministry of Communications & Information Technology, Department of Electronics and Information Technology), Plot no.p-1,
More informationTENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN KARNATAKA & ANDHRA PRADESH ZONE
TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN KARNATAKA & ANDHRA PRADESH ZONE Bank of Baroda Zonal Office, KARNATAKA & ANDHRA PRADESH Zone, 2 ND
More informationDate of Start and downloading the tender 12 sep 2018
INDRAPRASTHA INSTITUTE OF INFORMATION TECHNOLOGY-DELHI (IIIT-DELHI) Okhla Industrial Estate, Phase III New Delhi 110020 (Tel No 011-26907400, Website: www.iiitd.ac.in) Notice Inviting Tender for Non Comprehensive
More informationA. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section.
SECTION 16770 PAGE 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section. B. Division 16
More informationRelationship beyond banking
Relationship beyond banking Zonal office, Agra Zone Jeevan Prakash, 1st. Floor, LIC Building, Sanjay Place, Agra 282 002 Phone : 0562-2521642 Email: Agra.God@bankofindia.co.in COST OF TENDER : Rs. 500/-
More informationSTAR HOUSE BANK OF INDIA NATIONAL BANKING GROUP NORTH-I H-2 CONNAUGHT CIRCUS Middle/Outer Circle, Phone No
TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN JAIPUR AND JODHPUR ZONES STAR HOUSE BANK OF INDIA NATIONAL BANKING GROUP NORTH-I H-2 CONNAUGHT
More informationRavi Malik General Manager
/For release in Newspaper/ TENDER NOTICE Tenders are invited by Bank of Baroda, Western UP & Uttarakhand Zone, First Floor, 129- D, Civil Lines, Bareilly 243001for the Supply, installation (As and when
More informationSTATEMENT OF WORK. System Description:
STATEMENT OF WORK Scope of Work: To install a paging/sound system throughout the Rapid City Swim Center (RCSC). This work shall includes all labor, material equipment and related services necessary to
More informationTENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONE UNDER
TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONE UNDER SILIGURI ZONE, OPP: M B AUTOMOBILES PRANAMI MANDIR ROAD, SILIGURI (WB) PH: 0353-2641718
More informationEXPRESSION OF INTEREST CONSULTANCY SERVICES FOR GIVING FACELIFT TO BHEL GATES & LAND SCAPING OF SOUTH AVENUE AT BHEL-R.C.
EXPRESSION OF INTEREST CONSULTANCY SERVICES FOR GIVING FACELIFT TO BHEL GATES & LAND SCAPING OF SOUTH AVENUE AT BHEL-R.C.PURAM, HYDERABAD PREAMBLE BHEL Hyderabad is the leading Central Public Sector undertaking
More informationBANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL: , TENDER NOTICE FOR
BANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL:0522 6677645, 6677647 TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING
More informationIndian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.
Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi -110003, Ph. No. 011-49854100 TENDER NOTICE Sealed tender in two separate bids a) Technical bids,
More informationNATIONAL LAW UNIVERSITY, DELHI Sector-14, Dwarka New Delhi
NATIONAL LAW UNIVERSITY, DELHI Sector-14, Dwarka New Delhi-110078 NOTICE INVITING TENDER FOR SUPPLY AND INSTALLATION OF INFRARED VERIFOCAL INDOOR DOME CAMERA AT NATIONAL LAW UNIVERSITY, DELHI Date of issue
More informationEMPANELMENT OF AUDITORS FIRE SAFETY AUDITOR ELECTRICAL SAFETY AUDITOR IMPORTANT DATES:
EMPANELMENT OF AUDITORS FIRE SAFETY AUDITOR ELECTRICAL SAFETY AUDITOR IMPORTANT DATES: S.No Particular Date 1) Date of uploading details for empanelment on Bank's website 05/06/17 2) Opening date for submission
More informationTENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS
TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS Bank of Baroda Zonal Office, Northern Zone, Bank of Baroda
More informationNOTICE INVITING TENDER
NOTICE INVITING TENDER Ref No.: SCOPEMINAR/MMO/18-19/183 Dated :- 06.12.2018 1. Online e-tenders are invited by Dy.General Manager, SCOPE on behalf of Constituents of SCOPE MINAR, Laxmi Nagar Delhi- 110092
More informationThe following are the terms and conditions for the firms for submission of bids:
To, As per list enclosed, No.D-13011/1/2016-Genl. Government of India Ministry of Textiles ****** Udyog Bhawan, New Delhi, dated March, 2016 Subject: Annual Maintenance Contract for repair/maintenance
More informationTable-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion
Table-1: Clarifications and modification in tender s based on Pre-bid meeting discussion Sr. Ref Page. 1 4 Clause Site Preparation and Partitions walls 2 11 SLD 3 18 Batteries 4 18 Batteries 5 32 to 34
More informationANNEXURE-III BUILDING MANAGEMENT SYSTEM (BMS) BMS Total ANNEXURE-III. SL DESCRIPTION OF ITEM UNIT QTY Rate in figures Rate in words AMOUNT
PRICE BID Name of the Project : Supply, Installation, Testing and Commissioning of BMS, PA, CCTV, AVS, Access Control System for Construction of Partially completed Building at Centre for Development of
More informationBANK OF BARODA BARODA CORPORATE CENTRE MUMBAI
BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI TENDER NOTICE FOR ANNUAL MAINTENANCE CONTRACT AND REFILLING OF FIRE EXTINGUISHERS AT BANK OF BARODA CORPORATE OFFICE BUILDINGS IN MUMBAI NAME OF WORK: Bank
More informationFIRE SOLUTIONS >> FIRE EXTINGUISHERS DRY POWDER WATER CARBON DIOXIDE FOAM FEATURES
PRODUCT CATALOGUE FIRE SOLUTIONS >> FIRE EXTINGUISHERS There are basically four different types of fire extinguishers each of which extinguishes specific type of fire. Extinguishers use picture/labeling
More information.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.
Issued 2005/06/01 Section 13704 Video Surveillance Page 1 of 10 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Video cameras..2 Video handling..3 Recording devices..4 Transmission methods. 1.2 RELATED SECTIONS.1
More informationVideo Surveillance Remote Devices and Sensors
DIVISION 28 ELECTRONIC SAFETY AND SECURITY JVC Professional Products Company Division of JVC AMERICAS CORP. 1700 Valley Road Wayne, New Jersey 07470 (800) 582-5825 www.jvc.com/pro This product specification
More informationTENDER FOR EMPANELMENT OF VENDORS
TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES LOCATED IN ANDHRA PRADESH, TAMIL NADU, KERALA, TELENGANA, KARNATAKA & ANDAMAN & NICOBAR ISLAND
More informationOffer your customers a high end solution for a low end price. Complete alarmsystem with integrated 24/7 camera surveillance Immediate Push Alarm on mobile phone including photo and video-recording Camera
More informationSecurity designed for your lifestyle
Security designed for your lifestyle The Paradox Insight : The Big Picture A single CAT5 or higher cable can be used to wire a single HD77 camera. Camera Detector Module HD 720p camera Quad PIR with auto
More informationDepartment of Biochemistry University of Lucknow Lucknow
Department of Biochemistry University of Lucknow Lucknow-226007 TENDER NO.: LU-Biochem COE/001/2017 Dated: September 20, 2017 Short term Tender/Bid invited for Construction/fabrication of an airconditioned
More informationS.No. Description Unit (approx.) Unit price Total amount
SECURITY INSTALLATION LOT CCTV CAMERA S.No. Description Unit (approx.) Unit price Total amount 3 Network Video Recorder for up to 6 IP camera inputs, HDMI output, VGA Output, BNC output, ch Audio Input
More informationBank of Baroda Zonal Office, Tamil Nadu and Kerala Zone, Baroda Pride, New No.-41, Luz Church Road, Mylapore, Chennai
TENDER NOTICE FOR SUPPLY, INSTALLATION, REFILLING AND ANNUAL MAINTENANCE OF FIRE EXTINGUISHERS INCLUDING AMC OF EXISTING & OLD SYSTEMS AT DIFFERENT BRANCHES OF BANK OF BARODA OF TAMILNADU & KERALA ZONE
More informationTender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE
Relationship beyond banking Zonal Office, Bhopal Zone Bank of India Bhawan Jail Road, Arera Hills BHOPAL - 462011, MP. Phone. 0755-2764698 zo.bhopal@bankofindia.co.in ZOBDSDSGNFE TENDER2013-14 Dated 05.11.2013
More informationVPS3 Installation Manual
1-512-756-1678 VPS3 Installation Manual VPS3 Viewer (Local Unit) VPS3 Sender (Remote Unit) Content Introduction...2 Features...2 Packing Checklist...2 Patents...2 Limited Warranty...2 Overall Certificate...3
More informationNotice inviting Tender for Development of Signature Stall
Notice inviting Tender for Development of Signature Stall Spices Board (Ministry of Commerce & Industry, Govt. of India) has launched the process for establishing signature stalls for Spices in major cities
More informationPurchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems
Purchase: 2015-16(Fire Fighting) May 26, 2015 Sub: Quotation for AMC of Fire Fighting Systems Dear Sir, The Institute of Company Secretaries of India is a statutory body set up by an Act of Parliament.
More informationSUPREME COURT OF INDIA ADMN. MATERIAL BRANCH NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT FOR RE-FILLING OF FIRE EXTINGUISHERS
SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH LAST DATE OF TENDER : 5 th April, 2018 F.NO. 423/F.E./18/SCI(AM) DATED: 15 th March, 2018 NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT
More informationSmart Security, Always Connected
Smart Security, Always Connected Products Presentation 2018 www.maxkin.com Achieved FINALIST Status at IFSEC s Security & Fire Excellence Awards 2014,2016 Innovative Technology WiFi/GSM Dual-Network FHSS
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationAccess CONTROL. MANAGEMENT Software
Software Guide Access CONTROL MANAGEMENT Software Engineered to meet today s demands and tomorrow s challenges, Keyscan s System VII software delivers unique features to provide an access control solution
More informationMOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram
More informationD-TECT 3 IP. GJD260 IP Motion Detector
D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationGMS GRAPHICAL MANAGEMENT SYSTEM
GMS GRAPHICAL MANAGEMENT SYSTEM 1 GMS Security management system for multi-site organizations. PACOM Graphical Management System (GMS) is the modular client-server application that integrates all of PACOM
More informationOffer your customers a high end solution for a low end price. Complete alarmsystem with integrated 24/7 camera surveillance Immediate Push Alarm on mobile phone including photo and video-recording Camera
More informationDS-2TD Thermal & Optical Network Bullet Camera
DS-2TD2836-50 Thermal & Optical Network Bullet Camera Introduction Hikvision DS-2TD2836-50 Thermal Bi-spectrum Network Bullet Camera is applied to perimeter defense and fire-prevention purposes in critical
More informationDatasheet Face Recognition [Genetec VMS]
Datasheet Face Recognition [Genetec VMS] Version 3.6 This Specification Sheet gives the details of system requirements, features and other salient points of AllGoVision Face Recognition application for
More informationRequest for quotation (RFQ) for goods/services
Request for quotation (RFQ) for goods/services Firefighting equipment s and alarm system for UNICEF Warehouse Khartoum - Soba RFQ No: SDPC/89588/SERVICES/RFQ-135 Request for quotation (RFQ) for (Firefighting
More informationG-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System
PS-4001-48461-A G-MAX IVS R123 Sensors Perimeter Intrusion Detection System Product Specifications G-Max Security Tech Ltd a l d o r e c o t e c L td. I n t e g r a t e d S e c u r i t y s y s t e m s
More informationVISTA 48DLCT HONEYWELL SECURITY
VISTA 48DLCT HONEYWELL SECURITY Agenda Introduction Product Features Benefits Advantages VISTA 48DLCT Package Vista 48DLCT System Wired Wired Keypad CIA Modem For Partners / Retailers Wired LCD Keypad,
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationUNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System
UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION All in One - All in Touch Video - Alarm System UNICA is a revolutionary alarm system based on architecture all-in-one composed by a burglar alarm (wired and
More informationD3D Wi-Fi GSM Smart Alarm System -User Manual
D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM
More informationControl Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2
Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationApplication for Registration of Fire Protection Consultant on Record
Application for Registration of Fire Protection Consultant on Record Fire and Emergency Services Surat Municipal Corporation Muglisara, Surat 395 003, Gujarat, India Phone : 91-261-2423751 56 Extn.- 229/322
More informationBANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL: , TENDER NOTICE FOR
BANK OF BARODA, ZONAL OFFICE, EASTERN U.P ZONE, BARODA HOUSE, V-23, VIBHITI KHAND, GOMTI NAGAR, LUCKNOW, TEL:0522 6677647, 6677645 TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS
More informationThe most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation
The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of
More informationAMENDMENT NO.: III INVITATION FOR BID NO.: GPA FOR
January 26, 2018 AMENDMENT NO.: III TO INVITATION FOR BID NO.: GPA-022-18 FOR PHYSICAL SECURITY AND ACCESS CONTROL SYSTEM (ACS) REPAIR AND UPGRADE AT VARIOUS GPA LOCATIONS Prospective Bidders are hereby
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationWIRELESS CCTV. Oil, Gas and Renewables Site Security.
WIRELESS CCTV Oil, Gas and Renewables Site Security Wireless CCTV Wireless CCTV (WCCTV) is a market leading, customer focused provider of portable, redeployable surveillance solutions. WCCTV manufactures
More informationB. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.
SECTION 281300 - ACCESS CONTROL SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Minimum standards for Access Control Systems. B. Related Requirements: 1. Section 087100 Door Hardware. 1.2 REFERENCES
More informationThe last date of submission of responses has been extended up to 14: 00 hrs on 20/07/2018.
TCIL/S&TC/2017-18/AIPS Dated: 17.07.2018 Corrigendum No. 11 Sub: Amendment for Pre-bid Tie-Up for selection of OEM / Master Integrator for the design, supply, installation, commissioning & CAMC of perimeter
More information38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS
SPECIFICATIONS FOR LV DIGITAL PANEL METERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationTW-8000 TAUT WIRE FENCE
TW-8000 TAUT WIRE FENCE www. rbtec. com Email: info@rbtecom GENERAL TW-8000 Product information INTRUDALERT is a powerful electronic system specifically designed for total perimeter protection of critical
More informationSECTION INTRUSION DETECTION
(NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION
More informationTENDER NOTICE FOR. Page 1 of 30
TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF INTEGRATED ALARM SYSTEM AT DIFFERENT BRANCHES OF BANK OF BARODA IN WESTERN U.P.& UTTARAKHAND ZONE HAVING ITS
More informationWIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING
>SMART GPRS WIRELESS ALARM SYSTEM CR200 INTRUSION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING INTRUSION HOME SECURITY CR200 is a smart GPRS modern, effective and versatile 30-zone
More informationProfile. For a better understanding of this product, please read this user manual thoroughly before using it.
Intelligent GSM Auto-Dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm
More informationAnnexure - 1. Detectors: Fire Alarm Control Panel :
Item 1. Supply Part This Specification includes Supply, Warranty, Installation, Testing and Commissioning and integration of the Fire Alarm System mainly consisting of the Fire Alarm Control Panel (FACP),
More informationHDCVI PIR Camera User s Manual
HDCVI PIR Camera User s Manual Version 1.0.1 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Detection Range... 4 4 Device Installation... 5
More informationD-TECT 2 IP. GJD230 IP Motion Detector
D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper
More informationUD-VMS510i. Surveillance Management Center
Surveillance Management Center Introduction VMS510i is a flexible, scalable, high reliable and powerful central management system. Client-Server Architecture, Integrating with multiple surveillance systems.
More informationDESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM APROX.
TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM APROX. 46 in Nos. at DIFFERENT BRANCHES IN _ Bihar Orissa Jharkhand Zone And Annual Maintenance
More informationCentered on future family lifestyles, Lechange provides a newer, better quality of life and experience for consumers. Through providing a complete series of new products and services for numerous scenarios
More informationSTATE BANK OF INDIA CHENNAI CIRCLE
STATE BANK OF INDIA CHENNAI CIRCLE INVITATION FOR EXPRESSION OF INTEREST (EOI) FROM APPLICANTS HAVING EXPERTISE IN INSTALLATION AND MAINTENANCE OF a) FIRE ALARM SYSTEM b) BURGLAR ALARM SYSTEMS AT VARIOUS
More informationWESTERN ZONAL OFFICE ENGINEERING DEPTT. WEST WING, FIRST FLOOR, "YOGEKSHEMA, NARIMAN POINT MUMBAI
ENROLMENT FORM FOR DATA CABLING / AUTOMATIC FIRE ALARM AND DETECTION SYSTEM WESTERN ZONAL OFFICE ENGINEERING DEPTT. WEST WING, FIRST FLOOR, "YOGEKSHEMA, NARIMAN POINT MUMBAI - 400021 FORM FOR ENROLMENT
More informationMovement Detector GJD 300
Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before
More informationThe Challenger Version 8 User Guide
The Challenger Version 8 User Guide CONTENTS Function included in your system Introduction...4 Glossary... 6 The Challenger Console.. Liquid Crystal Display... 9 Keypad...10 Indicator Lights...11 User
More informationFiber Optic Cable Fence Disturbance Sensor
Architectural & Engineering Specification for Fiber Optic Cable Fence Disturbance Sensor Purpose of document This document is intended to provide performance specifications and operational requirements
More informationEXPANDABLE SMART HOME SECURITY KIT
EXPANDABLE SMART HOME SECURITY KIT SKU Code: SHA5108 SMART HOME AUTOMATION WITH SECURITY ALARM & OUTDOOR SIREN (2 way RF 868Mhz communication). ALL MANAGED VIA 1 APP ON YOUR SMARTPHONE Indoor IP Camera
More informationPROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS
SECTION 26 92 50 PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationBURGLAR ALARM PANEL BS-468
BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced
More informationTENDER DOCUMENT FOR RATE CONTRACT FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES
TENDER DOCUMENT FOR RATE CONTRACT FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES Zonal Office, Bhopal Zone Bank of India Bhawan Jail Road, Arera Hills BHOPAL - 462011, MP.
More informationPanel XTO210/610/710 GPRS
P r o d u c t S p e c i f i c a t i o n s S h e e t Doc. - Ref. 220-XTO Version : Juin 2013 Description Supervised Wireless Technology The XTO control panel is a Videofied weatherproof, wireless, battery
More informationSUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.
SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING Table of Contents Section Title Page 1 Introduction 2 2 Proposed Schedule 2 3 Instructions
More information