FOR THE FUTURE OF OUR ENVIRONMENT

Size: px
Start display at page:

Download "FOR THE FUTURE OF OUR ENVIRONMENT"

Transcription

1 B.E.G. PRESENCE DEPENDENT LIGHT LINKED TIME CTROLLED FOR THE FUTURE OF OUR ENVIRMENT With B.E.G. energy saving = cost reduction + environmental protection

2 B.E.G. The pole caps are melting, sea levels are rising, freak storms are getting worse and increasing in frequency all as a consequence of increased CO 2 emissions. B.E.G. is aware of these changes and, with its extensive range of presence detectors, the use of energy-saving bulbs in lights and heating regulators, is helping to reduce CO 2 emissions and protect resources. Energy is precious which is why saving it, also means protecting the climate and environment and conserving resources to save the place in which we live. Saving energy with B.E.G. also means cost reduction and environmental protection. With the aim of satisfying demands for a clean environment, B.E.G. has developed products that contribute to optimum light and heat management in accordance with requirements and that comply with the latest environmental protection guidelines and directives issued by the European Union. For an environment worth living in! 2

3 ENERGY SAVINGS POTENTIAL B.E.G. The need for energy saving The need for energy saving has increasingly come to the fore since the Kyoto Protocol, individuals and industry becoming ever more aware of its importance. An urgent priority is to make a contribution to reducing the greenhouse gas CO 2 ; a challenging task on account of increasing industrial development. As a consequence of the Kyoto Protocol, the European Union has issued various instructions with the aim of analyzing and optimizing energy consumption between the countries involved. Furthermore, the G8 Summit in 2009 reached an international agreement that the average temperature worldwide must not rise by more than 2 C by 2050, in order to contain climate change. In particular for the commercial sector, our industry can provide a range of options for energy saving: Lamps with high luminous efficiency, energy-saving electronic ballasts, lights with optimized light direction, dimming electronic ballasts, timers, light sensors and presence detectors. B.E.G. has combined extensive energy-efficient products in its range. Measurements verify that daylight provides up to 80 % of the light in a typical office in central Europe during the summer months, with the result that the share of energy-consuming artificial light can be reduced to 20 %. Light is energy energy is life! 3

4 B.E.G. Typical annual consumption (approx values) Total 67% 33% Lighting Health 63% 11% 4% 13% 9% Heating and hot water Education 51% 15% 2% 11% 12% 9% Air-conditioning and ventilation Traffic and transport 48% 16% 7% 8% 2% 20% Food storage Industrial sector Sport and leisure Other Retail trade Department stores 43% 17% 10% 15% 4% 10% 43% 15% 5% 6% 4% 16% 35% 32% 5% 8% 4% 16% 34% 23% 10% 9% 3% 23% Computers Other Offices 32% 22% 21% 3% 15% 6% Hotels and catering 32% 12% 11% 34% 1% 10% Authorities 26% 24% 7% 11% 17% 15% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 4

5 TIME-CTROLLED PRESENCE-INDEPENDENT LIGHT-ORIENTED B.E.G. Power consumption for lighting depends on many factors if an optimal lighting requirement is to be established without unnecessary switch on times for the light. These include the switch-on time of the light, the amount of daylight the room receives as well as a suitable manual or automatic light monitoring. Simple but effective light monitoring can include the use of day, week and season timers, dimmers and automatic devices for reducing energy and costs. And what is more, these products are easy to install or retrofit into existing applications. A further automatic solution can involve the use of motion or presence detectors with daylight and mixed light measurement, thus ensuring integration of the daylight in the general lighting. Both in the management of light as well as in building control tasks, presence detectors can contribute to achieving considerable energy savings: presence detectors switch on lamps, heating and ventilation only when they are actually needed. They also incorporate the available daylight into the general lighting and thus also utilize natural resources. Presence detectors are motion sensors with a detection angle of 360 that have been designed for installation in ceilings and indoor use and that regulate overall brightness by measuring different sources of light (natural or artificial). B.E.G. s range includes presence detectors for all applications and for all special requirements. For more energy efficiency in buildings! 5

6 B.E.G. Options for energy and cost reduction with presence detectors Storerooms Corridors Toilets Conference rooms Lighting is an essential cost factor in the energy consumption. In some buildings, this can be up to 50 % of the total electricity costs. Training rooms Open-plan offices Individual offices 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% Energy saving potential 6

7 ENERGY SAVING AND CTROLLING = COST REDUCTI + ENVIRMENTAL PROTECTI B.E.G. PRESENCE DEPENDENT INDEX PRESENCE DEPENDENT Occupancy detectors... Switching with 1 or 2 channels Dimming with 1 or 2 channels Networked and BUS- operated use 8-13 LIGHT LINKED LIGHT LINKED Staircase timer... Photo electric switches... DIN-rail Device installation Remote controllable Wall and post mounting Ceiling mounting TIME CTROLLED TIME CTROLLED Digital time switches... Weekly time switches Astro time switches [Function of a twilight switch + time-controlled switching] Yearly time switches Analogue time switches "e-metering" Monitoring the energy consumed... VBox-System

8 B.E.G. INTELLIGENCE AT HOME - LIGHT THROUGH MOTI Presence detector positioning Presence detector spacing M/S M max. distance = x+y S x y The maximum motion detection is reached when walking across the path of the detector, not when walking in a straight line up to the front of the detector. It is especially important to consider this for corridors. Detection ranges can overlap so as to avoid potential "dead zones". 8

9 ENERGY SAVING WITH MOTI AND OCCUPANCY DETECTORS B.E.G. In a bulleting of January 15, 2009, German Government announced a directive for promoting climate protection measures in social, cultural and public institutions as part of the climate protection initiative. This addresses the renovation of indoor, hall and outdoor lighting amongst other issues. In particular, the installation of efficient lights with electronic ballasts and efficient illuminants with additional installation of a daylight-dependent power control and/or presence control, as well as a time control and/or presence control in corridors and stairwells. Presence detectors are designed for detecting moving heat sources in their detection range such as persons entering a building. Presence detectors (motion detectors with mixed light measurement) respond to the slightest movement, e.g. working at a desk. Presence detectors are particularly effective in smaller rooms such as bathrooms, toilets or storerooms, as they only switch on the light when a person is present in the room, so as to save energy in the building. B.E.G. presence detectors are also ideal for light monitoring in offices, as they are not only able to detect large movements but also minor activities such as people sitting. If no further movement is detected in the area, the presence detector automatically switches off the light and hence minimizes the energy consumption enormously. B.E.G. presence detectors contain a photoelectric cell, which detects natural daylight and controls the light during periods of time with a high level of ambient light. This prevents unnecessary energy consumption. For maximum security and convenience! Switching with PD 1 or 2 channels Switching with PD-Master 1 or 2 channels Switching with PD-Master- DUO 2 channels Dimming with PD-Master 1 or 2 channels 9

10 B.E.G. INDIVIDUAL LIGHTING WITH CSTANT LIGHT MEASUREMENT Example: energy and environment balance sheet Mode / bulb 4 Lights 4 x 14 W T5 Savings Consumption in kwh /year with an average life span of 8000 h CO 2 emission reductions/ year Also available trees for CO 2 reduction Costs per year at 0.20 /kwh Toilet lighting with PD3 with MD without MD 56 kwh 448 kwh 392 kwh 196 kg* x 9** * 0.5 kg CO 2 for generating 1 kwh with mean energy mix ** 1 tree absorbs around 20 kg CO 2 / year without MD (motion detector) = permanent light (mean total of the time lamps are switched on approx. 8 h in 24 h) with MD = light only on with movement (mean total of the time lamps are switched on approx. 1h in 24 h) 10

11 ENERGY SAVING WITH DIMMABLE OCCUPANCY DETECTORS B.E.G. B.E.G. dimmable and presence detectors with daylight integration use a phase control for reducing or increasing the average voltage for the lighting load. The diagram below shows this process. This dimming method provides numerous energy saving options, as it reduces the total consumption for the lighting enormously in dimmed situations. The B.E.G. can also be controlled by external switches or buttons. Presence and daylight-oriented light switching! ENERGY SAVING WITH DIMMERS Switch on Switch on A typical application: Off On Switch off Off On A large restaurant with two walls almost entirely of glass has dimmable lighting installed for individual setting and adjustment to the desired lighting conditions in every eating area using an external switch. When there is adequate daylight, the use of a presence detector ensures that the area near the window only becomes brighter with natural light, thus saving energy during this time. 11

12 B.E.G. ENERGY SAVING WITH OCCUPANCY DETECTORS FOR ANY BUS APPLICATI DALI, DSI, KNX/EIB, L, RADIO and Powerline - the compact, energy-efficient and versatile light control systems from B.E.G. B.E.G. can provide just the right presence detector for every application. Diverse detection zones and ranges up to approx. 20 m radius and installation heights up to approx. 10 m are possible. Numerous special solutions enable use of predominantly remote-controlled detectors, e.g. in corridors, in rooms with 2 lighting zone, in wet rooms or for applications without direct visual contact. Cash value of an annual saving of euros at assumed capital costs of 5 %: 1352 euros! Annual energy cost saving with B.E.G. [in %] Motion detector with daylight integration Additionally, B.E.G. s range includes presence detectors for all BUS applications: DALI, DSI, KNX/ EIB, L and special 24 V solutions. The new digital detectors (PD2, PD4 and PD9), successors to the analogue presence detectors with dimming function, permit users to control both DSI and DALI electronic ballast systems. Modes may be selected by remote control: Four different modes are available with the KNX/ EIB versions: normal mode (switching), semi- or fully-automatic mode with constant light control (dimming), slave mode and alarm function. L versions have more than seven device functions. Besides the sensor, KNX/EIB and L presence detectors also possess corresponding BUS connectors. The required software is also included while it may also be simply downloaded from B.E.G. s homepage at For individuality and quality! Presence detector with daylight integration DIM detector with constant light control max. 49% 12

13 SWITCHING WITH 1 OR 2 CHANNEL PRESENCE DETECTORS WITHOUT DAYLIGHT INTEGRATI Occupancy detector Surface mount Ceiling mount Flush mount Presence detection Motion detection Remote controllable PD3-1C/2C (only 1C-device) Ø 10 m also with Micro PD4-1C Ø 24 m PD4-1C-C max. 40 m Corridor detector PD9-1C Ø 10 m extremely narrow PD9-1C-GH max. 5,40 m greater heights Indoor 180-R max. 10 m Indoor 180-T max. 10 m Indoor 180-SC max. 10 m Range Notes Relay version with Micro Triac version with Micro for staircase switches SWITCHING WITH 1 OR 2 CHANNEL MASTERS WITH DAYLIGHT INTEGRATI Occupancy detector Surface mount Ceiling mount Flush mount Presence detection Motion detection Remote controllable PD2-M-1C Ø 10 m PD4-M-GH Ø 24 m greater heights PD5-M-Clip Ø 10 m Range Notes for T8 and T5 fluorescent tubes PD9-M Ø 10 m extremely narrow PD9-M-GH max. 5,40 m greater heights PD9-M-SDB Ø 10 m extremely narrow PD9-M-SDB-GH max. 5,40 m greater heights PD1-M 7,50 x 7,50 m quadratic range PD2-M Ø 10 m PD4-M Ø 24 m PD4-M-C max. 40 m Corridor detector Indoor 180-M max. 10 m PD4-M-DUO Ø 24 m DUO detector DIMMING WITH 1 OR 2 CHANNEL MASTERS WITH DAYLIGHT INTEGRATI Occupancy detector Surface mount Ceiling mount Flush mount Presence detection Motion detection Remote controllable PD1-M-DIM 7,50 x 7,50 m quadratic range PD2-M-DIM Ø 10 m PD4-M-DIM Ø 24 m PD4-M-C-DIM max. 40 m Corridor detector PD5-M-DIM-Clip Ø 10 m Range Notes for T8 and T5 fluorescent tubes PD9-M-DIM Ø 10 m extremely narrow PD9-M-DIM-GH max. 5,40 m greater heights PD4-M-DUO-DIM Ø 24 m DUO detector PD4-M-TRIO-DIM Ø 24 m with HVAC channel 13

14 B.E.G. WITH SWITCH- ADVANCE WARNING THE STAIR LIGHT TIMER LUXOMAT Manual switch for minute or permanent light Top-hat rail standard housing (1 TE) 62,5 x 17,5 x 85 mm Manually adjustable timer, 30 sec. to 10 min. For use with B.E.G. staircase timer LUXOMAT Indoor 180-SC Quick attachment for 35 mm profile rail 14

15 ENERGY SAVING WITH STAIRCASE TIME SWITCH B.E.G. Stair light switch for optimum light control The previous pages have shown typical applications for individual products in order to save energy and costs. Further reductions can be achieved with combinations of these products. For example, you can make an effective contribution to reducing energy costs with a motion detector as a wall switch in conjunction with the stair light switch. The B.E.G. stair light switch SCT1 is easy to install, based on a small housing and can quickly be mounted on a profile rail. While the stair light wall switch only switches the light if a movement is detected, the stair light switch ensures that the lighting only remains switched on for as long as it is actually needed. In combination with a timer, entire time periods can also be controlled, for example at weekends or during vacation. See the full spectrum! Electronic 3- or 4-wire circuit Can be connected downstream Low-noise max. incandescent light load 2300 W max. 100 ma rest current for illuminated switches with glow lamps Rated voltage 230 V/50-60 Hz With switch-off advance warning 15

16 B.E.G. SAVING ENERGY BY SWITCHING LIGHTS IN RESPSE TO TWILIGHT Wherever lights need to be switched based solely on the brightness value at daybreak or at the end of the day, photoelectric switches are just the right choice. Light sensors measure the ambient light and switch the lighting on or off depending on the preset twilight value. Lighting is not usually necessary at certain times of the day. With B.E.G. products, the light can therefore be controlled in relation to the twilight, thereby saving energy. To this end, B.E.G. provides twilight switches for various applications: for profile rails, installation in devices, wall or mast mounting as well as a remote-controlled product. The LUXOMAT TS-DD has an electronics unit for installation in distributors for convenient setting in the control cabinet as well as a separate light sensor for surface mounting or interior installation. The LUXOMAT CDS-R is designed for retrofitting in outdoor lights and for use in junction boxes. The integrated timer in the remotecontrolled LUXOMAT CdS-T-SM allows you to accurately program energysaving periods, for example at certain times during the night, at the weekend or during public holidays. Considerable amounts of energy and money can be saved. Remote controllable. The LUXOMAT CdS-SM comes with the option of precisely setting the light value and switch-on or switch-off delay via a potentiometer from outside as well as via an integrated automatic function (10 Lux / 40 sec. switch-on / 120 sec. switch-off delay). As a twilight switch with special spring terminals, the LUXOMAT CdS-FC is also easy to mount on the ceiling thanks to its small dimensions (visible height after installation 6 mm). Remote controllable. Light-oriented energy saving! 16

17 OVERVIEW PHOTO ELECTRIC SWITCHES Photo electric switch Surface mount Ceiling mount Post mounting Device installation DIN-rail Switching power Remote controllable TS-DD 3000 W CdS-R 1000 W CdS-T-SM 2300 W CdS-SM 2300 W CdS-FC 2000 W Time delay 17

18 B.E.G. OVERVIEW DIGITAL TIME SWITCHES WEEKLY TIME SWITCHES Digital time switch TS-DW1 TS-DW2 TS-DW3 Mechanical design DIN-rail mounting DIN-rail mounting DIN-rail mounting Front dimensions in mm Memory location Relay / Channel Data key Pulse / Timer Cycle Notes 17,5 x Channel 1 data pulse 35 x Channel 1 data pulse 35 x Channel 1-2 data pulse ASTRO TIME SWITCHES Digital time switch TS-ASTRO1 TS-ASTRO2 TS-ASTRO3 Mechanical design DIN-rail mounting DIN-rail mounting DIN-rail mounting YEARLY TIME SWITCHES Digital time switch TS-DY1 TS-DY2 Mechanical design DIN-rail mounting DIN-rail mounting Front dimensions in mm Memory location 17,5 x Channel 1 Relay / Channel Data key Pulse / Timer Cycle Notes 35 x Channel 1 data xtern* 35 x Channel 1-2 data xtern* Front dimensions in mm Memory location * one channel switch Relay / Channel Data key Pulse / Timer Cycle Notes 35 x Channel 1 data pulse zyklus dcf 71,5 x Channel 1-4 data pulse zyklus xtern / dcf 18

19 ENERGY SAVING WITH DIGITAL TIME SWITCHES B.E.G. Illuminated display Symbol and text based menu Keypad fast to operate Possibility to fold up covering to protect the buttons ASTRO TIME SWITCHES YEARLY TIME SWITCHES Control of the channels, programming with PC Direct programming with data key for an easy data transmission from the PC with programming software WEEKLY TIME SWITCHES PROGRAMMING WITH A PC Data key It is possible to generate a print-out of the program as a recording for later reference. Holidays/permanent program and / periods can also be programmed. The switching program can be back-up easily on a PC or transferred to the data key to copy a switching program from one digital time switch to another. In connection to the data key, the programming package is a useful extension for the time switch.you are able to comfortably program a switching time from your PC and save switching times on your data key via USB-interface. Electronic time switch Data key Data key Adapter USB for programming PC Software 19

20 B.E.G. TIME SWITCHES FOR EASY ENERGY SAVINGS Daily program 24h prog Irrespective of the day of the week the same switching program is carried out each day. Multiple switching functions can be programmed within 24 h. 12:00 PM 12:00 AM 11:59 PM Weekly program week prog Depending on the day of the week (Mo - Su) different daily programs can be configured. Unrestricted block programming allows a free choice of days of the week within one switching function. The choice of switching functions is the following:,, permanent by date (holiday), pulse (pulse not available in astro time switches). 12:00 PM Monday Tuesday Wednesday Sunday 12:00 AM 11:59 PM Astro program/ Solar program astr Astronomical or solar time swtiches can be used as an alternative to twilight switches (also known as photo-electric or day/ night switch). When using an astro time switch NO light sensor is needed. By means of astro switching times (Astro / Astro ) the time switch automatically calculates the start of dusk in the evening or the beginning of dawn in the morning and calculates the time for sunset and sunrise respectively. This calculation is updated each day throughout the whole year. Additionally, conventional switching functions of a weekly time switch can be programmed (,, (holiday) permanent by date). Evening Astro Light on Night Night Night Light on Astro Morning Offset: A chronological offset can be entered. This offset customises the astro switching times. Therefore the time switch can execute an astro switching time either before or after sunset/sunrise or, if the offset is left at zero, exactly at sunrise/sunset. Position/location: To guarantee exact calculation of local sunset and sunrise times, you can easily enter your approximate geographical coordinates (longitude and latitude). 20

21 Yearly program year prog Yearly time switches are suitable to achieve more sophisticated time controls compared to standard weekly programs. By means of special (weekly) programs different weekly programs can be carried out within different periods during the year (from start date to end date). Easter function: One additional function when carrying out a special weekly program is the Easter function. If you selected it for a period with start date and end date, these dates, are shifted by the shift of Easter holiday for successive years (Gaussian Easter formula). This function is applicable for holidays e.g. Ash Wednesday, Palm Sunday, Maundy Thursday, Good Friday, Easter Day, Pentecost, Feast of Corpus Christi, Carnival. Special program August August Monday Tuesday Wednesday Sunday Special program 1 Start date - End date Monday Tuesday Wednesday Sunday 11:59 PM 11:59 PM Extra switching time: A further feature is the extra switching times. Single switching times can be programmed for a specific date (e.g. Anniversary). The residual switching program remains unaffected. A helpful add-on is the option weekday function. If you assign this to your extra switching time the shift of this weekday of the month will be taken into account for successive years. E.g.: A switching time that should be carried out every 2nd Saturday of February every year. Special program 1 Start date - End date Monday Tuesday Wednesday Sunday 11:59 PM In order to save energy and costs, one can use a yearly time switch with four channels in a little office or on a commercial property. One channel could control the lighting during the evening in order to avoid unnecessary energy costs. Another channel could ensure that the local heating is switched off during the weekend and in holiday time, when the building is not occupied. A third channel could control the shop window or external signboards during the time between 10 p.m. and 7 a.m.. The last channel could regulate the hot water function to ensure that water inside the building is not heated during the weekend and holiday time. ENERGY SAVINGS YEARLY TIME SWITCH Power density max. power density 10 W/m² max. power density 10 W/m² Configuration Typical open-plan office 300 m² Typical open-plan office 300 m² -Switching of the light 11 hours 260 days 1 weekends 1 nights in a month 11 hours 260 days Consumption kwh /year 8580 kwh /year 2664 kwh /year 25 % savings 21

22 B.E.G. FUNCTIAL OVERVIEW / MEANING OF PICTOGRAMS Permanent by date (holiday function) You have the possibility to switch a channel during a period (from start date to end date) permanently or. Pulse function pulse The pulse function is a function for a switching time with defined pulse length ranging from 00:01 to 59:59 mm:ss. Timer function timer (only for manual and external trigger signals) The timer function can only be started by an external signal (external input) or by the channel buttons of the time switch. The switching performance is identical to the pulse function The pulse length is greater and ranges from 0:00:01 h:mm:ss to 9:59:59 h:mm:ss. The timer function is also known under following terms: On-pulse or Single shot. Cycle function cycle The cycle function can be used to program a continuous switching time. The time switch operates then as an asymmetrical recycler (pulse/pause). The independently adjustable max pulse/pause lengths are 9:59:59 h:mm:ss. 4 different memory locations are reserved for 4 different cycles. Channel button You can assign different switching functions to each single channel. This function is carried out when either pressing the corresponding channel button of the time switch or optionally by addressing the channel from the external input. The different switching functions are the following: / (predefined setting, see alse manual override ), cycle, timer, permanent. External iput xtern The external input can be used as external trigger for different functions (/, cycle, timer, permanent). The signal connected to the external input can be of type switch or push-button. Staircase lighting timer: When using the timer function and advanced warning function. Glow lamp load of the external input: Max. 75 ma (Used to supply the glow lamp in suitable light switches; not available in 70 mm versions.) Advance warning function A useful function for lighting applications according DIN Two-fold flashing warns of darkness. Radio controlled clock dcf Some time switches can be controlled by radio receiver (Part number 92683). The time switch is then synchronised to the time standard signal DCF77. The transmitter is located close to Frankfurt/Main (Mainflingen). The range is approx km. Data key function data Time switches with this function can be programmed by data key TS-ACC-DS1 (accessory). The functions are as follows: - Data back-up of the time switch - Programming the time switch with the pre-programmed key program - Time switch executes only the key program 22

23 Programming package TS-ACC-DS1/2: A useful accessory for the data key TS-ACC-DS1 is the programming package TS-ACC-DS2. You can easily program your switching program with the PC and transfer it to the time with the data key switch. Removable programming module: data The data key function is included within the removable module of the time switches TS-DW1 and TS-ASTRO1. In additional to manual programming these modules are also programmable with a programming package. The modules plugs into the PC interface (no data key needed). Decoding of the type designations Product name: TS D W 1 Version Typ (W = Weekly, Astro = Astro, Y = Yearly time switch) Execution (A = Analogue / D = Digital) Product family PIN-Code pin Security by PIN-coding. Display with back light lcd For a better contrast of displayed symbols, digits and letters. Permanently and (manual) By pressing the corresponding channel button for more than 3 sec. the channel is permanently switched or. Manual override By pushing the channel button the corresponding channel will change its status. Time counter h Time switches with integrated time counter are counting operation hours and the number of switchings of each channel as well as the operation hours of the time switch. 23

24 B.E.G. OVERVIEW MECHANICAL TIME SWITCHES DAILY TIME SWITCHES Mechnical time switch TS-AD1 TS-AD2 TS-AD3 TS-AD4 Mechanical design DIN-rail mounting DIN-rail mounting DIN-rail mounting DIN-rail mounting Front dimensions in mm Power back-up Minimum interval Power supply 230 V Time base Accuracy Notes 17,5 x min. Quartz crystal ±1,5sec./day 17,5 x min. Quartz crystal ±1,5sec./day 52,5 x min. Quartz crystal ±1,5sec./day Minute hands 52,5 x min. Quartz crystal ±1,5sec./day Minute hands WEEKLY TIME SWITCHES Mechnical time switch TS-AW1 TS-AW2 Mechanical design DIN-rail mounting DIN-rail mounting Front dimensions in mm Power back-up Minimum interval Power supply 230 V Time base Accuracy Notes 52,5 x 45 2 hrs Quartz crystal ±1,5sec./day Minute hands 52,5 x 45 2 hrs Quartz crystal ±1,5sec./day Minute hands 24

25 ENERGY SAVING WITH MECHANICAL TIME SWITCHES B.E.G. Manual override switch permanently / AUTO Easy to read switching program Easy programming with captive setting keys Mechanical display (clock hands) DAILY TIME SWITCHES WEEKLY TIME SWITCHES The analog or mechanical timers are a simple alternative for keeping a quick and convenient eye on times. An operating switch allows you to choose between the permanently and automatic functions. The time can be programmed and read with ease using the captive switch buttons. 25

26 B.E.G. ENERGY MEASURING AND SAVING WITH LUXOMAT SMARTHOME PRODUCTS Funk-Aktor Intelligente Steckdose 26 Funk-Monitor MyControl

27 EASY CSUMPTI MEASUREMENT VIA E-METERING ACTUATOR AND DISPLAY B.E.G. SINGLE PHASE DIRECT ENERGY MEASUREMENT Technical data MyControl Measuring accuracy acc IEC1036 Class 2 (2 %) Current strength max. Power supply Switch 16 A ~ direct Single phase 230 V ~ 50 Hz complete and partial with reset The power consumption of electrical devices is measured in kilowatt. With the help of emetering the energy consumption of individual devices can be calculated in kilowatt hours. The monitor shows a diagram with the current consumption. On an additional page, the total consumption is shown after a re-set. In order to analyse a longterm testing more precisely, data can be saved on a SD-card and is transferred to a PC. Keep track of your energy the easy way with B.E.G.! Easy reading of the measured values Direct light measurement User-friendly menu guidance View of the tendencies in table form Quick checking of the power consumption For an efficient cost reduction 27

28 B.E.G. THE SYSTEM SOLUTI IN E PACKAGE plug and play Several adjoining offices in Master-/Slave-Operation Slave Slave Slave M3 230 V M3 230 V M3 230 V Master Master Master 28 The simple installation of occupancy and motion detectors.

29 THE SAFE, FAST AND COST-REDUCING CNECTI WITH SYSTEM B.E.G. The B.E.G. LUXOMAT VBox and VLBox modules constitute innovative solutions for the installation market when B.E.G. presence detectors are used in cost-saving suspended ceiling installations. Thus B.E.G. is following the trend now widespread in building engineering of offering pre-fabricated fast, cost-reducing and safely functioning components. The B.E.G. range of presence-sensors are available pre-wired. The functioning of the modules is tested at the factory to ensure functional safety. The modular concept means that changes may be easily implemented both during the installation as well as later when requirements change. The pre-wired system is also a response to the lack of qualified personnel because it uses plug connectors that are colour-coded and protected against being incorrectly connected (inverse polarity), which means that they can also be installed by non-skilled workers. Qualified electricians only need to carry out checks and commissioning after installation. Laborious wiring of individual terminals is no longer required, which results time and cost savings. Fast, safe, error-free Simple plugging Just re-plug somewhere else when requirements change flexibility today and tomorrow Cost-efficient» Wage costs up to 70 % savings» Wage + material up to 30 % savings All presence sensors also alternatively available as pre-wired versions Eight boxes for various presence sensor types with different colour codes Also for DUO and DIM devices 29

30 B.E.G. Plug and socket for the power supply Extension cable for flexible wiring 230 V 230 V M1 VBox PD3-/PD4-/ PD9-1 Channel Pre-wired B.E.G. - presence detector Integrated plug connector in the lamp T-piece for connecting lamps to each other Connection cable for pre-wired lamps 30

31 BENEFITING FROM ENERGY SAVINGS WITH B.E.G. B.E.G. COST COMPARIS [in %] Time and cost savings during installation: less staff, less administration, fewer tools, installation in record times Wages Materials without B.E.G. VBox system with B.E.G. VBox system Quality and economy during commissioning: no cabling errors, guaranteed safety, fewer errors during cabling, fewer accidents Service continuity and flexibility during ongoing operations: less maintenance work, faster and simpler intervention when requirements change Energy savings in buildings through the use of B.E.G. presence sensors: presence- and daylight-dependent lamp switching and dimming 0 Typical applications: conference rooms, classrooms, nursery schools, corridors, toilets and offices 31

32 ISO ISO 9001 ISO Environmental management Quality management B.E.G. (UK) Ltd. Q West, Great West Road Brentford, Middlesex, TW8 0GP Tel: +44 (0) Fax: +44 (0) info@beguk.co.uk Internet: B.E.G. Ireland Marlin Enterprise 10 Vesey Place Monkstown Dun Laoghaire, Dublin Tel: +353 (0) Fax: +353 (0) Internet:

B.E.G. STILL EVEN BETTER!

B.E.G. STILL EVEN BETTER! B.E.G. STILL EVEN BETTER! ENERGY IS LIFE For the future of our environment B.E.G. The pole caps are melting, sea levels are rising, freak storms are getting worse and increasing in frequency all as a consequence

More information

B.E.G. LUXOMAT. Find the right detector.

B.E.G. LUXOMAT. Find the right detector. B.E.G. LUXOMAT Find the right detector www.beg-luxomat.com B.E.G. B.E.G. SMARTPHONE APP The new B.E.G. remote control app 92726 Rapid programming by smartphone The B.E.G. remote control app is the easiest

More information

B.E.G. Already heard of it? News

B.E.G.   Already heard of it? News B.E.G. Already heard of it? News 2014 Discover energy-savings potentials with OCCULOG* and convince your clients! How to save energy Knowing today about your energy-savings for tomorrow It is common knowledge

More information

B.E.G. PRESS KIT 2013

B.E.G. PRESS KIT 2013 B.E.G. PRESS KIT 2013 www.beg-luxomat.com Motion detectors Occupancy detectors Automatic lights Halogen and LED floodlights Energy saving floodlights Time switches Photo Electric switches Emergency and

More information

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1.

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1. Highlights 2013/1 www.beg-luxomat.com SMARTHOME product combinations Motion and occupancy detectors Lights and photocells Starter Set 4 radiator control for saving energy wirelessly controlled V-Boxes

More information

B.E.G. PRESS KIT 2012

B.E.G. PRESS KIT 2012 B.E.G. PRESS KIT 2012 www.beg-luxomat.com Bewegungsmelder Präsenzmelder Automatikleuchten Halogen- und LED-Strahler Energiesparstrahler Zeitschaltuhren Dämmerungsschalter Not- und Sicherheitsleuchten Netzwerkprodukte

More information

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR GB Contents 1. GENERAL 1 1.1 KNX bus basics 1 1.2. Overview 1 1.3 Symbols 1 2. OCCUPANCY DETECTOR BASICS 2-3 2.1 Introduction 2 2.2 Motion detection with the B.E.G.

More information

. SMARTHOME B.E.G. The comprehensive solution for home automation. Energy efficiency Fire safety. Comfort

. SMARTHOME B.E.G. The comprehensive solution for home automation.  Energy efficiency Fire safety. Comfort B.E.G.. SMARTHOME The comprehensive solution for home automation www.beg-luxomat.com Energy efficiency Fire safety Comfort SMARTHOME ~ The comprehensive solution for home automation How the SMARTHOME works

More information

LUXOMAT Application examples for electricians and planners

LUXOMAT Application examples for electricians and planners LUXOMAT Application examples for electricians and planners Plan with B.E.G. comfortably and certainly Along with a great number of useful practical tips, in this chapter you will also find many application

More information

NEWS THEBEN THEBEN 2

NEWS THEBEN THEBEN 2 english NEWS 2010 NEWS THEBEN THEBEN 2 THEBEN NEWS New Theben products in 2010 THEBEN Dear clients and partners, Find out about our new products and energy-saving solutions for building automation: The

More information

Description of the application programme for KNX occupancy detectors version 3.1

Description of the application programme for KNX occupancy detectors version 3.1 Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1

More information

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. NOTE:

More information

Electronic controllers. Comfort embellishes everyday life

Electronic controllers. Comfort embellishes everyday life Electronic controllers Comfort embellishes everyday life Comfort and security Comfort embellishes everyday life An electronic blind controller from Schenker Storen brings added value, however, it is anything

More information

Save energy. ARGUS presence detectors

Save energy. ARGUS presence detectors Save energy Ef cient energy use 2 Keeping energy costs down Increasing energy costs and growing awareness of the environment in modern buildings management now mean that more innovative solutions for efficient

More information

Connections, displays and operating elements C D E G H. Installing the control unit

Connections, displays and operating elements C D E G H. Installing the control unit 1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried

More information

HF Motion Sensor Introduction

HF Motion Sensor Introduction HF Motion Sensor Introduction Completely built-in the lighting fixture, the motion sensor utilizes Doppler principle and RADAR technology to detect moving objects at certain speed & reflection surface,

More information

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G. B.E.G. LUXOMAT net KNX intelligent building automation using sensors from B.E.G. Effective energy saving in buildings 2 KNX sensors from B.E.G. are specially developed for the creation of economical solutions

More information

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual

More information

Trios Training Manual

Trios Training Manual Trios Training Manual Version 1.2, June 2002 TRIOS training-manual 1. 2 1 1. TRIOS SYSTEM INTRODUCTION... 2 The Trios Concept... 2 Trios Multi-functionality... 2 Trios Flexibility... 2 Trios Simplicity...

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 4 START-UP All parameter settings are carried out via the ETS (Engineering Tool Software). The magnet provided can be used to activate the programming status for the physical address on the PD-ATMO 360i/8

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions

More information

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1 Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) DALI/DSI output channels with adjustable negative offset from channel to channel 1 Ambient light

More information

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor ILD Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or DALI devices (max. 5 per output channel) 2 DALI/DSI output channels

More information

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure. The world-wide standard for home and building control Applications for correctional facilities Greater efficiency and cost-effectiveness with GAMMA building control Answers for infrastructure. Successful

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Product and Applications Description

Product and Applications Description Product and Applications Description The presence detector with a sensing range of 360 allows the automatic execution of control functions in the electrical system by detecting movements. For example,

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

FR-A180 FR-A360. Occupancy detector. Use

FR-A180 FR-A360. Occupancy detector. Use 5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable

More information

DALI SPECIFICATION GUIDE

DALI SPECIFICATION GUIDE DALI SPECIFICATION GUIDE Page 2/3 contents Page 1. INTRODUCTION 6 2. DALI - THE STANDARD 6 2.1. Industry standard 6 2.2. Light control 6 2.3. Digital control 7 2.4. Switching in the electronic ballast

More information

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications Simple Fit Switching Sensors 1.8m to 3m Cone-shaped detection pattern, 6m radius at mounting height 6.0m AC220~240V/50Hz MK Simple Fit Sensors offer cost effective presence detection for lighting control

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

SMART BASIC BASIC-IR DAYLIGHT

SMART BASIC BASIC-IR DAYLIGHT LUXMATE Lighting Control System LUXMATE. The ing system for maximum quality and dimming convenience. SMART BASIC BASIC-IR DAYLIGHT The art of modern technology lies in making complicated things simple.

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs lighting management - stand alone detectors, power packs 488 03 488 20 488 07 488 06 Pack Cat.Nos Traffic detection - Infrared technology Ceiling mounting detector Set via a thumbwheel 1 488 03 360 - detection

More information

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions - Brochure tekmarnet 4 Thermostat 542 D 542 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

B.E.G. LUXOMAT net. DALISYS Intelligent Lighting Control and more

B.E.G. LUXOMAT net. DALISYS Intelligent Lighting Control and more SYS Intelligent Lighting Control and more SYS The Building Solution What is SYS? SYS is an innovative bus system for lighting control based on, comparable in operation. Our large range of SYS occupancy

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings A Title 24 Code Review for Electrical Professionals By: Brian Friedel LEED AP brian.friedel@wattstopper.com

More information

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

GE Lighting. Lighting Controls. DALI Digital Lighting Controls GE ighting ighting Controls I Digital ighting Controls the I Protocol Multi-functional control of I-ready GE uminaires 1-1 to I converters available for analogue luminaires I CB Type 2 - complete programmable

More information

AmpLight group management

AmpLight group management AmpLight System Guide AmpLight group management Table of Contents System description.... 3 Benefits...4 Features....4 Central dimming....5 Benefits....5 Features....5 AmpLight Modules...6 Coded mains...8

More information

Sensors and Detectors

Sensors and Detectors 12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental

More information

RF Programmable Room Thermostat User Instructions

RF Programmable Room Thermostat User Instructions ESRTP4RF RF Programmable Room Thermostat User Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition

More information

KNX/EIB - Product database - Application description

KNX/EIB - Product database - Application description KNX/EIB - Product database - pplication description Theben HTS KNX/EIB Product Database V3.2 for Theben HTS presence detectors ECO-IR 360EIB-C ECO-IR 180EIB-C ECO-IR DUL-EIB compact office EIB compact

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

EBMHS (standard & slim-line PSU)

EBMHS (standard & slim-line PSU) Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic

More information

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS Hol Man Auto Day SIGNAL HEATING ON OVERRIDE

More information

Canolux LED. Petrol Station Forecourt Luminaires

Canolux LED. Petrol Station Forecourt Luminaires Canolux LED Petrol Station Forecourt Luminaires Point source LEDs provide excellent opportunities to direct light accurately improving uniformity and reducing the electrical load. Well designed and manufactured

More information

- Data Brochure tekmarnet 4 Thermostat 542e

- Data Brochure tekmarnet 4 Thermostat 542e - Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products May 2016 ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and

More information

LED Compatible Daylight Harvesting and Motion Sensor System

LED Compatible Daylight Harvesting and Motion Sensor System MADE IN GERMANY BY OUR FRIENDS AT EPV DH1 Technical Data MAX. MOUNTING HEIGHT AMBIENT TEMP. CURRENT CONSUMPTION 5m 0 50 C (Indoor) max. 15mA at 24V SWITCHING CAPACITY Occupancy Signal: Max. Dimming Status

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

Saving energy with Gira

Saving energy with Gira Need-based lighting and heating only if required energy can be saved using just a few functions. Stabilising room climate Functions for room climate control and blind control decrease the energy expenditure

More information

Movement-based energy control

Movement-based energy control 04 Movement-based energy control 94 International catalogue 2015 4.1 Microwave-based movement sensors 4.2 PIR-based movement sensors 4.2.1 Ceiling-mount 4.2.2 Wall-mount 4.3 Twilight switches 4.4 LED lights

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level

More information

e.control Function overview

e.control Function overview e.control Function overview 2012/2013 e.control TM - unlimited functionality Due to the significance of automation for the energy efficiency, economy and ergonomics of a building, a new planning approach

More information

UP 258E11 OPTISENS OFFICE

UP 258E11 OPTISENS OFFICE Product and functional description The UP 258E11 is a presence/motion detector with integrated 2-point light control. The UP 258E11 device communicates via KNX/EIB with actuators or other KNX devices.

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

Lighting & Controls Motion & Presence Detectors

Lighting & Controls Motion & Presence Detectors Lighting & Controls Motion & Presence Detectors Let there be light But efficiently, please! Lighting control plays an important role in modern facility management. Not only to produce ideal living and

More information

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable. New thinking Sentus Automation is able to control and manipulate data at ease whilst delivering a low cost per point return. XML interface: Information can be exported/viewed by an unlimited number of

More information

On initial power up the thermostat will guide you through set up procedure for the following:

On initial power up the thermostat will guide you through set up procedure for the following: Operating Guide: for the Warmup 3iE Programmable Thermostat INTRODUCTION Your thermostat s default screen is the Home Screen. This screen displays important information such as the time, current floor

More information

Your partner for intelligent street light systems

Your partner for intelligent street light systems Your partner for intelligent street light systems Content List esave ag What is esave slcontrol? The esave slcontrol-controller Software and Control esave slcontrol-server with gateways 3 4 7 8 10 esave

More information

Product Comparison Guide

Product Comparison Guide Product Comparison Guide EnOcean 902MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution Control Performance Energy savings Better building management Table of contents EnOcean

More information

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR 8. SPECIFICATION LOAD 6 Amps fluorescent and incandescent lighting. 3 Amps compact fluorescent lighting. 3 Amps low energy lighting. 3 Amps low voltage lighting (switch primary of transformer). Switch

More information

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks.

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks. www.osram.com/lightingsolutions Light is simple The LED damp-proof luminaire range for challenging lighting tasks. Light is OSRAM Product Efficient in diverse situations is the tried-and-true range of

More information

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm). Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)

More information

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01 Gamma instabus Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG1 528-1DB01 Technical Product Information Universal Dimmer for switching or dimming of dimmable lamps Supports dimmable lamps including

More information

PIR movement and presence detectors 10 A

PIR movement and presence detectors 10 A PIR movement and presence detectors 10 A Hotel room energy-enabling units ighting control in corridors (for hotels, offices and hospitals) Offices, swimming baths and schools SЕRIES Staircase light control

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

B.E.G. The lighting control professionals.

B.E.G. The lighting control professionals. The lighting control professionals www.beg-luxomat.com PRESS KIT 2017 INDEX P1 Professional solutions for building automation New products from 3 P2 Lighting control for projects of any size The DALISYS

More information

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure. Synco- Application Guide School building class room Answers for infrastructure. More efficiency in schools with Synco and building control Requirements Single source Objective of this document School

More information

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light PRODUCT CATAOGUE IGHT CONTRO Grässlin products for the intelligent control of light ight control: Selective use of lighting thanks to intelligent light control Motion and presence detectors Twilight switches

More information

Direct Dim Microwave Presence/Absence Detector

Direct Dim Microwave Presence/Absence Detector Product Guide MWS3A-DD Direct Dim Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3 5 Fixing

More information

Imperial War Museum. Case Study 17. clipsal.com UNITED KINGDOM. C-Bus Control and Management System

Imperial War Museum. Case Study 17. clipsal.com UNITED KINGDOM. C-Bus Control and Management System Imperial War Museum UNITED KINGDOM C-Bus Control and Management System Case Study 17 clipsal.com C-Bus brings Visionary Manchester Landmark to Life The Imperial War Museum North is the first building in

More information

11,1 30. Ordering data

11,1 30. Ordering data ID Compact control module with ambient light sensor and motion sensor Compact dimensions for luminaire installation For up to 10 DSI or I ballasts I/DSI output channels with adjustable negative offset

More information

Controller Specification Sheet

Controller Specification Sheet Controller Specification Sheet MC9550ABXXBX Proportional Inhibitor Dosing, Dual Conductivity Bleed Control, Dual Point ph Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol

More information

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI 2015.10 Control Guide Content: 1 2 3 4 5 6 7 8 9 10 11 Ensure right physical install of all hardware / use remote control to commission

More information

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual

More information

Tri-level Control Sensor

Tri-level Control Sensor Daylight Monitoring Photocell Advance TM One-Key Commissioning Ambient daylight threshold oop in oop out Tri-level Control Sensor HC038V HCD038 Detached inear Version with Remote Control Applications Occupancy

More information

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs. MPAD-C-A-DALI-230V Product Guide Ceiling microwave presence detector DALI / DSI Overview The MPAD-C-A-DALI-230V microwave presence detector provides automatic control of lighting loads with optional manual

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

Analogue Dimming Microwave Presence/Absence Detector

Analogue Dimming Microwave Presence/Absence Detector Product Guide MWS3A-AD Analogue Dimming Microwave Presence/Absence Detector Contents Section Contents Page 1 Dimensional information 1 2 Description and operation 2 3 Wiring & Fixing 3 4 Installation 3

More information

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way SMARTER BUILDING Busch-Presence detectors Energy saving the easy way 2 BUSCH-PRESENCE DETECTORS ENERGY SAVING THE EASY WAY Modern light management Saving costs with innovation Presence detectors automatically

More information

Built-in HF Sensor for High Bay

Built-in HF Sensor for High Bay Daylight Monitoring RX TM Synchronisation control Ambient daylight threshold Built-in HF Sensor for High Bay HC419VRC/R Tri-level Control With Synchronisation and Remote Control Applications Occupancy

More information

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator Lifestyle Electric Thermal Radiator Complies with Lot 20 Eco-design Heating Directive 2009/12/EC. Effective January 2018 ALUMINIUM Euro Edition Issue 1 August 2017 Next Day Delivery Order before 3.00pm

More information

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator Lifestyle Electric Thermal Radiator Complies with Lot 20 Eco-design Heating Directive 2009/12/EC. Effective January 2018 ALUMINIUM Euro Edition Issue 1 August 2017 Next Day Delivery Order before 3.00pm

More information

Programmable multi-functional energy saving lighting control. Easy to install and commission

Programmable multi-functional energy saving lighting control. Easy to install and commission ControlZAPP PROGRAMMABE IGHTIG COTROS Programmable multi-functional energy saving lighting control ControlZAPP is the innovative lighting controls range the freedom to configure the best energy saving

More information

Model: Touch-RS. 1 Touch-RS

Model: Touch-RS. 1 Touch-RS Model: Touch-RS Model: Touch-RS 1 Touch-RS Table of Contents Product Image 1 Temperature Hold 15 Table of Contents 2 Holiday Programming 16 What is a Programmable Room Thermostat? Installation Procedure

More information

Use of the application program

Use of the application program Contents overview Use of the application program Use of the application program 1 1. Functional description 2 Switching on / off 2 Dimming brighter / darker 2 Dimming value (8 bit) 3 Status Switching (1

More information

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS CHAPTER 15: TRAINING SYSTEMS FOR ELECTRICAL INSTALLATIONS 527 Training Panel to Electrical Protective Measures 528 Training Panel to Installation Tests

More information

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control Ocean Breeze 2951 SE Dominica Terrace, Stuart, Florida 34997 Tel: 772 2200038 obr@oceanbreezeac.com http://www.oceanbreezeac.com

More information

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500 0073-1-7613 Rev. 01 06.2011 KNX Technical Reference Manual Busch Präsenz tech 6131/10-500 6131/11-500 KNX Technical Reference Manual Busch Präsenz tech 1 Safety instructions Work on the 230 V power supply

More information

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013 WHITE PAPER Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard 90.1-2010 & 2013 JUNE 2016 DT213 (Rev.10.2.17) Executive Summary ASHRAE Standard 90.1 is developed with the Illuminating Engineering

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules ENOTEC modular system 110046819 Control CD I 110046818 Control CD CO1 110046814 ensor ED HF1 110046813 ensor ED HF2 110046816 ensor ED PIR Function description The new ENOTEC

More information

Stellar Panelboard Dimming Systems

Stellar Panelboard Dimming Systems create a new dimension in lighting control. While lighting systems consume energy, Stellar dimming panels conserve and redirect energy into the atmosphere of your facility. The panel s universal dimmers

More information