Stoebich. Flexible Fire & Smoke Curtains. Innovation for your Protection! Stoebich

Size: px
Start display at page:

Download "Stoebich. Flexible Fire & Smoke Curtains. Innovation for your Protection! Stoebich"

Transcription

1 Stoebic Flexible Fire & Smoke Curtains Automatic fire & smoke curtains Stoebic Fire & Smoke Curtain S Stoebic Fire & Smoke Curtain H / HC Stoebic Fire Curtain U Stoebic Fire & Smoke Curtain P Stoebic Fire & Smoke Curtain E Stoebic Fire Curtain W Stoebic Fire Curtain F Stoebic Fire Curtain I Stoebic Fire Curtain V Automatic fire tigt curtain Stoebic Fire Curtain T Control units RZ 8 RZ 7 Stoebic Fire & Smoke info@stoebic.us,.stoebic.us Innovation for your Protection!

2 Protection concepts it automatic textile fire curtain: 1. For openings in alls Ho to seal large openings in alls ic create fire compartments according to te protection target altoug te available space is limited or oter arcitectural demands exist? 2. For openings in ceilings Ho to seal large openings in ceilings ic create fire compartments according to te protection target even toug te available space is limited or arcitectural demands exist? Tese automatic systems are very small and easily integrated into any situation. You may coose beteen te protection targets up to 4 ours fire rating or up to 120 minutes insulation ( invisible fire protection ). Tese automatic systems are very small and easily integrated into any situation. You may coose beteen te protection targets up to 2 ours fire rating, up to 60 minutes integrity it limitation of eat transmission, or up to 120 minutes insulation ( invisible fire protection ). Stoebic Fire & Smoke Curtain: Stoebic Fire Curtain U Stoebic Fire & Smoke Curtain P Stoebic Fire & Smoke Curtain E Stoebic Fire Curtain I Stoebic Fire Curtain T Stoebic Fire Curtain V Stoebic Fire & Smoke Curtain H/HC. For fire protection ic goes around te corner Provided tat no limitations caused by side guides or columns can be accepted (as in te case of prestigious buildings). Ho to adjust te existing ig demands of fire protection closures to arcitectural constructions even en it as to create a room or as to go around te corner? Te Stoebic Fire Curtain offers a polygon saped design itout te necessity of disturbing side guides but still maintaining te required tigtness. Due to te flat design, te system is easily integrated into ceilings and can be built it extremely large idts and lengts.were as te angle may be beteen 0 and 150. Stoebic Fire & Smoke Curtain S 4. For openings in facades in corner situations Wen buildings or parts of a building connect to eac oter in a corner situation or if tey are separated by a fire all, no openings in te fire all are alloed. Ho to guarantee tis if operable indos are planned? Te protection is assured by te possibility to install tem inside or outside te building. Wit tis automatic sealing system, operable standard indos itout firerated glazing can be used. Terefore, te room comfort is not restricted. Stoebic Fire Curtain F 5. For openings in facades it a minor distance beteen te buildings Subject to a loer deviation of tese requirements te adjacent alls need to be designed as fire alls. Openings ave to be closed in a fire-resistant manner to avoid te passage of fire. Ho to guarantee tis if operable indos are planned? Te protection is assured by te possibility to install tem inside or outside te building. Wit tis automatic sealing system, operable standard indos itout fire-rated glazing can be used. Terefore, te room comfort is not restricted. Te robust functionality is approved by a eatering test for 10 years created by a German testing laboratory. Stoebic Fire Curtain F Stoebic Fire Curtain W 6. For openings in facades and canopies Wen te roof of building extensions join to alls it openings or to alls ic are not fire-retardant. Ho to solve tis problem? Te protection is assured by te possibility to install tem inside or outside te building. Wit tis automatic sealing system, operable standard indos itout fire-rated glazing can be used. Terefore, te room comfort is not restricted. Stoebic Fire Curtain F Stoebic Fire & Smoke Curtain H/HC 7. To prevent te passage of fire from one level to anoter A textile fire protection closure designed as a barrier tat prevents te passage of flames from one level to anoter. Ho to solve tis problem itout limiting te field of vie? Fire protection closures ic are integrated into a building and being activated by fire detection or a termal release mecanism automatically, create a f ire barrier in te case of fire. Stoebic Fire Curtain W Stoebic Fire & Smoke Curtain E Stoebic Fire & Smoke Curtain P 8. To create a section Te creation of sections itin fire compartments limits te risk of fire to especially endangered macines or installations. Ho to acieve suc a sealing? Te Stoebic Fire Curtain creates te required alls or even ceilings. In case of a fire, tese rooms can be flooded by ig pressure ater-spray extinguising systems or gas extinguising systems tat douse te fire. Te fire protection systems are designed in dependence on te alloed leakage. Systems it side guides are used to matc te ig demands concerning tigtness for gas extinguising systems. Stoebic Fire Curtain U Stoebic Fire & Smoke Curtain P Stoebic Fire Curtain I Stoebic Fire & Smoke Curtain E

3 Stoebic innovative fire & smoke protection Smoke extraction by automatic or fixed textile smoke curtains 2. Smoke curtains it a curved course. Automatic textile smoke curtain it te feasibility to pass troug 4. Creation of areas for smoke conduction or as fire protection closure 5. Automatic textile fire & smoke tigt curtain 6. Automatic textile fire curtain for openings in alls 7. Automatic textile fire curtain itout side guides 8. Hig speed door it integrated fire protection 9. Automatic textile fire curtain for openings in ceilings 10. Automatic textile fire curtain for facades, exterior installation 11. Conveyor system closures for uninterrupted and interrupted conveyor systems 12. Conveyor system closures for pneumatic conveyor systems 1. Automatic textile fire curtain it Hose Stream test 14. Elevator saft doors as fire protection closure 15. Fire protection stacking door 16. Isogate fire protection insulation doors and gates 17. Fire protection ood for electric devices 18. RZ 7, RZ 8, AMU control units 19. CAN BUS cross linked old open units 20. Emergency poer back up unit Poerdrive VAC Attention: Textile fire curtains are not regulated in te Building Code and as to be approved by te local autorities as an alternate solution, means and metods. Stoebic Fire & Smoke Protection

4 Protection targets Definition Fire rating Test standard/ certificate x E Integrity Integrity is te resistance against fire to avoid a passage of flames or ot gases. Protection target EI (insulation) can be acieved by a fire load free zone: 0 min. insulation: x =.5' 60 min. insulation: x = 5' 90 min. insulation: x = 7' up to 4 ours fire rating UL 10B (20 min. fire rating) UL 10B (120 min. fire rating) UL 10C (20 min. fire rating) UL 10D (120 min. fire rating) NFPA 252 (20 min. fire rating) x EW Integrity it a limitation of eat transmission Limitation of te eat transmission is te caracteristic to reduce te eat being transferred troug a fire protection system to limiting materials. Protection target EI (insulation) can be acieved by a fire load free zone: 0 min. insulation: x = 0.7' 60 min. insulation: x = 1' 90 min. insulation: x = 1.7' up to 2 ours fire rating it limitation of eat transmission EI (insulation it sprinkler) Insulation it intensified sprinkler protection in case of fire Insulation is te ability of te system to avoid te transmission of fire caused by eat radiation. Te transmission as to be limited in a ay, tat neiter te opposite fire side surface nor any oter materials near to tis surface ignite and so persons are protected. up to ours insulation x x x = 0.7' - 1.7' depending on te environment EI (insulation it ater film) Insulation it ater in case of fire up to ours insulation EI (insulation itout ater) Insulation itout ater in case of fire up to 1 our insulation Transmission from one level to anoter Avoidance of transmission of flames from one level to anoter itout (it) balustrade Te necessary barrier (or lintel) eigt of.' is automatically created in case of fire Extinguising Creation of sections Limitation of a room ic is usually not tere to avoid te transmission of flames or ot gases to te room itout fire. Enclosure by textile fire protection closures it te targets: limitation of te fire, smotering of te fire, extinguising of te fire by gases or ater-spray. Enclosure by textile fire protection closures it te target to: limit te fire quenc te fire extinguis te fire it gases or ater-spray

5 Stoebic - References Nort America 2012 Harley Marine, Seattle, Wasington 2012 Historical Serlock Building, Portland, Oregon 2012 Hyatt Place Hotel, El Segundo, California 2014 Seaolm Poer Plant, Austin, Texas 201 Te University of Missouri, Kansas City, Missouri 2014 Ne Broad Museum, Los Angeles, California 2011 Sargento Foods, Plymout, Wisconsin 201 Parmaceutical Building, Princeton, Ne Jersey 2010 Vancouver Library, Vancouver, Wasington

6 Room creating textile fire protection closure itout any columns System description 2 ours fire rating according to UL 10D 20 minutes fire rating according to UL 10B, UL 10C, NFPA 252 closed polygon sape or open systems it connection to te all by special side guides, lengts up to 5' per side and a drop lengt up to 20' rectangular corners or angles from 0 up to 150 corners itout additional columns lo installation eigt self-leveling bottom bar (flus sealing it te ceiling) arp-free bottom bar drive unit it fail-safe tecnology (closing itout auxiliary poer) drive unit it 10,000 cycles redundant drive unit as fall protection additional unrolling fabric to form a camber for te insulation by inside ater sprinklers Drop lengt Perimeter Fabric Drop lengt of te system Stoebic Fire & Smoke Fabric E 00' 10' 1.6' 4.92'' Stoebic Fire & Smoke Fabric E 00' 10' - 20' 1.6' 8.86'' Stoebic Fire & Smoke Fabric H 00' 10' 1.6' 8.86'' Stoebic Fire & Smoke Fabric H 00' 10' - 20' 1.6' 17.72'' Stoebic Fire & Smoke Fabric E (insulation version) 00' 20' 1.97' 9.41'' At least 2 drive units and one more for eac ' above 66' perimeter Oter configurations and special design on request Range of runs of te fire protection closure Weigt of te system: 2 lbs per linear foot, side guides: 15 lbs per linear foot t Clear lengt (CL) Clear idt (CW) a a > 5' 6

7 Housing Housing (insulation version) Bottom bar 9.41" 4.92" 4.8" Side guide for open polygone 117 Protection targets Integrity it limitation of eat transmission Insulation it intensified sprinkler protection Insulation by ater mist in te intermediate layer " 11.42" 19." 6.81" 6.81" 21.97" 2.62" 11.42" 6.81" 19." Wit security device (infrared) (optional) 11.42" 4.61" Integrity 10.94" Pneumatical reset 8': manual reset possible, > 8': pneumatic reset required Pneumatic cylinder Side guide (insulation version) 9.84" Wall stump 7.09" Classification Fabric 250 Test standard / certificate 2 ours fire rating (UL 10D) 20 minutes fire rating (UL 10B, UL 10C, NFPA 252) Stoebic Fire & Smoke Fabric E UL 10B, UL 10C, UL 10D, NFPA 252, UL 864, UL 1784 OSHPD CA EW 0 Stoebic Fire & Smoke Fabric E Test report OPA IBS UB. / EI 90 Stoebic Fire & Smoke Fabric E IBS EI 120 Stoebic Fire & Smoke Fabric E EFR-14-G " Water irrigation " Metal plate as alternative for te all stump (optional) " 20"

8 f f Horizontal textile fire protection closure for openings in ceilings Stoebic Fire & Smoke Curtain HC - opened Stoebic Fire & Smoke Curtain HC - closed Stoebic Fire & Smoke Curtain HC to-part - closed System description - Stoebic Fire & Smoke Curtain HC system for large openings in ceilings itout supporting or tensioning cables up to ' x ' (to-part version up to ' x 66') ousing and bottom bar build a closed casing under operating condition motorized closing and opening (emergency poer supply is required) System description - Stoebic Fire & Smoke Curtain H system for large openings in ceilings up to 66' in idt and ig drop lengt tensioning cables in a distance of 5' to support te fabric it large dimensions as ell as for te pressure load in case of smoke ig variability in design (e.g. arc-sape) safe-closing process up to 17' drop lengt it gas spring (no auxiliary energy) or it duplex drive system (electrical poer supply is required) for drop lengt up to 0' spring system is closing it fail-safe tecnology Weigt of te system: 5 lbs per linear foot, side guides: 15 lbs per linear foot a Clear idt Clear lengt b Special design Deviation from te linear closing direction possible. System Spring Spring Clear idt Clear lengt 4.6' 5' 15' 9.5' a 4.72'' 4.72'' b 4.29'' 4.29'' 7.48'' 7.48'' 7.87'' 9.84'' f 7.48'' 7.48'' Spring 15' 9.5' ' 5.91'' 4.29'' 9.25'' 11.42'' 9.25'' Spring 15' - 100' 9.5' ' 5.91'' 8.86'' 9.25'' 12.60'' 9.25'' Longitudinal section in closing direction (oter scale) b Duplex HC (1-part) HC (1-part) 66' 20' ' 9.5' ' 20' ' 6.0'' 7.87'' 11.81'' 1.19'' 8.66'' 12.99'' 10.79'' 9.25'' 15.75'' 1.98'' 11.81'' 19.69''.15''.15'' 5.91'' 8 a Cross-section (oter scale) a 66' 11.81'' HC (2-part) ' Oter configurations and special design on request 19.69'' 15.75'' 19.69'' 5.91''

9 Stoebic Fire & Smoke Curtain HC (one-part): ousings b Opened condition Clear idt b Closed condition Clear idt b Stoebic Fire & Smoke Curtain HC (to-part): ousings Clear idt Opened condition Clear idt b Closed condition Clear idt b Stoebic Fire & Smoke Curtain H: ousings 14" 14" Side guide, bottom bar, feeding edge 14" 10.6" 10.6" 10.6" Fixed bearing Floating bearing f Protection targets a Under ceiling b Integrity Integrity it limitation of eat transmission Insulation it intensified sprinkler protection Area itout fire load Area itout fire load Blaze Classification 2 ours fire rating (UL 10D) 20 minutes fire rating (UL 10B) 2 ours fire rating (UL 10D) 20 minutes fire rating (UL 10B, UL 10C, NFPA 252) EI 120 ( classification) Fabric Stoebic Fire & Smoke Fabric P Stoebic Fire & Smoke Fabric H Stoebic Fire & Smoke Fabric P Test standard / certificate UL 10B, UL 10D, UL 864 OSHPD CA UL 10B, UL 10C, UL 10D, UL 864, UL 1784, NFPA 252 OSHPD CA Tested in Europe's biggest furnace Test report OPA UB III/B OPA G-021(one-part) 1-G (to-part) UB III/B

10 11. orld innovation First textile fire protection closure in te orld, tat passed te Hose Stream test according to UL 10B System description 2 ours fire rating according to UL 10B it Hose Stream test (ig stability) one-part it a idt up to 19' and a large drop lengt up to 15' drive unit it fail-safe tecnology (closing itout auxiliary poer) drive unit it 10,000 cycles only one drive unit is necessary (reduced effort for te installation) p a t e n t B R A N D S C H U T Z p e n d i n g Section B-B Clear idt 5.7".2" System idt Drop lengt 19' 15' 10.6'' 12.6" Oter configurations and special design on request System idt Section A-A Weigt of te system: 26 lbs per linear foot, side guides: 20 lbs per linear foot Drop lengt 10

11 site ousing run to te all, front site run Installation of ousings is ousing attaced to to te te ousing all, false on ceiling one side, front is attaced site runto te ousing on one side, front site run Side guides Installation of te ousing to te ceiling Installation of te Installation dimensions of te are in decimal inces ousing to te all ousing to te ceiling Installation dimensions of te are in decimal inces all dimensions are in decimal inces ousing to te all all dimensions are in decimal inces 10,6" 10,6" 10,6" 10,6" 11. orld innovation 12,6" 12,6" 12,6" 12,6" Continuous fabric clamping due to side guiding for ig pressures and ig tigtness Installation of te ousing to te all Installation of te ousing to te ceiling Sideguide all dimensions are in decimal inces Alternaties for te installation al inces Alternatives for te installation Alternaties for te installation 5,7" 5.7".2",1" Installation of te ousing to te all, front site run Installation of te ousing to te all, false ceiling is attaced to te ousing on one sid front site run Installation of te ousing to te all, front site run Installation of te ousing to te all, front site run Installation of te ousing to te all, false ceiling is attaced to te ousing on one side, Installation of te ousing to te all, false ceiling is attaced to te ousing on one side, front site site run run Installation of te ousing to te all all dimensions are in decimal inces Installation of te ousing to te ceiling all dimensions are in decimal inces ces Installation of te ousing to te ceiling all dimensions are in decimal inces 10,6" Protection targets 10,6" 10,6" Integrity 12,6" Insulation it intensified sprinkler protection 12,6" Insulation it ater film 12,6" Classification 2 ours fire rating (UL 10B) EI 120 EI 120 Fabric Stoebic Fire Fabric Herkutex Stoebic Fire Fabric Herkutex Stoebic Fire Fabric Herkutex Test standard / certificate UL 10B (it Hose Stream test), UL 864 OSHPD CA Test report OPA Water irrigation 2" 1" Tested by Intertek in Middleton Wisconsin 20" 20" 20" 11

12 Premium textile fire protection closure for ig requirements it large dimensions System description 2 ours fire rating according to UL 10D 20 minutes fire rating according to UL 10B, UL 10C, NFPA ours fire rating according to one-part it a idt up to 100' and a large drop lengt up to 0' ig variability in construction and design drive unit it fail-safe tecnology (closing itout auxiliary poer) drive unit it 10,000 cycles different protection targets (E, EW, EI) by using different types of fabrics self-leveling bottom bar, safety edge (optional) continuing lateral fixing of te fabric by using te side guides it steel rod for large drop lengts, ig pressure, ig tigtness and gentle closing Egress door optional it ICC-ES AC77 report and according to ADA (2010) System idt Fixed bearing Fabric System idt Drop lengt Stoebic Fire & Smoke Fabric H 2.6' - 1' 6.6' 7.48'' 9.84'' Stoebic Fire & Smoke Fabric H 2.6' - 1' 25' 9.25'' 11.41'' Stoebic Fire & Smoke Fabric P 2.6' - 5.2' 11' 7.48'' 9.84'' Weigt of te system: 2 lbs per linear foot, side guides: 1 lbs per linear foot Bottom bar a 1" 1" a a = Dimension for te side guide System idt Drop lengt Drop lengt Stoebic Fire & Smoke Fabric P 5.2' - 1' 11' 7.48'' 7.87'' Stoebic Fire & Smoke Fabric P 2.6' - 1' 11' - 20' 7.48'' 9.84'' Stoebic Fire & Smoke Fabric P 2.6' - 1' 20' - 0' 9.25'' 11.41'' Oter configurations and special design on request Widt-to-drop-lengt ratio: max. 1: Floated bearing Fabric System idt Drop lengt Stoebic Fire & Smoke Fabric H 1' - 40' 6.6' 7.48'' 9.84'' Stoebic Fire & Smoke Fabric H 1' - 40' 20' 9.25'' 11.41'' Stoebic Fire & Smoke Fabric P 1' - 72' 11' 7.48'' 7.87'' Stoebic Fire & Smoke Fabric P 1' - 72' 11' - 20' 7.48'' 9.84'' Stoebic Fire & Smoke Fabric P 1' - 66' 11' - 0' 9.25'' 11.41'' Oter configurations and special design on request Widt-to-drop-lengt ratio: max. 1: Bottom bar 12

13 Range of ousings Bottom bars 2" 2.8" 2.6" 1.7" 1.7" 1" 4,6 type 9,6 eavy type 5,61 narro type Standard - Fixed bearing Standard - Floated bearing Range of side guides Continuous fabric clamping due to rod guiding for ig pressures and ig tigtness Special construction Type Drop lengt Square footage 80 E 11.5' 194 ft2 105 E 20' 58 ft² 105 V 20' 754 ft² 160 E 0' 1,129 ft² 1.8" 2.4" 2.4".",84 F type,84 FK type Self-leveling bottom bar itout safety edge (optional) 1.8" Self-leveling bottom bar, it safety edge (optional) 1.8" Self-leveling bottom bar itout safety edge, under te ceiling (optional) 2.9" 2.9" 4" 2.9" 2.9" 2.9" 2.9" 2.9" 4" 4" 2.9" 2.9".1".1".1" 6." 4.1" 4.1" 4.1" 6." 6." 4.1" 4.1" 4.1" Type 105 E Type 105 E Type 105 E Type 105 V Type 105 V Type 105 V Type 80 E Type 80 E Type 80 E Type 160 E Type 160 E Type 160 E Installation to te all Installation in te embrasure Installation in te nice Installation to te all Installation in te embrasure Installation in te nice Installation to te all Installation in te embrasure Installation in te nice Installation to te all Installation in te embrasure Installation in te nice Alternatives for te installation Protection targets Integrity Integrity it limitation of eat transmission Insulation it intensified sprinkler protection Insulation it ater film Installation of te ousing to te all, front site run Installation of te ousing to te all, rear site run Installation of te ousing to te all, false ceiling is attaced to te ousing on one side, front site run Classification 2 ours fire rating (UL 10D) 20 minutes fire rating (UL 10B, UL 10C, NFPA 252) EW 90, EW 120 EI 120, EI 180 EI 90, EI 180 Installation of te ousing to te all, false ceiling is attaced to te ousing on one side, rear site run Installation of te ousing directly to te ceiling Installation of te ousing directly to te ceiling, false ceiling is attaced to te ousing on bot sides Fabric Test standard / certificate Stoebic Fire & Smoke Fabric P UL 10B, UL 10C, UL10D UL 864, UL 1784, NFPA 252 OSHPD CA Stoebic Fire & Smoke Fabric H Stoebic Fire & Smoke Fabric P Stoebic Fire & Smoke Fabric P Installation of te ousing to te ceiling by using angers Installation of te ousing to te ceiling by using angers, false ceiling is attaced to te ousing on bot sides Test report Water irrigation OPA UB III/B UB III/B UB. / UB. / UB III/B UB III/B UB III/B " UU IV/ UB III/B / Efectis-R0495 1" 20" 20" 1.5" 1

14 Economical textile fire protection closure it ig level of standardization Egress door optional it ICC-ES AC77 report and according to ADA (2010) System description 2 ours fire rating according to UL 10D 20 minutes fire rating according to UL 10B, UL 10C, NFPA 252 one-part it a idt up to 20' and a drop lengt up to 26' side guides it bobbins drive unit it fail-safe tecnology (closing itout auxiliary poer) drive unit it 10,000 cycles different protection targets (E, EW, EI) by using different types of fabrics self-leveling bottom bar, safety edge (optional) System idt Fabric System idt Drop lengt Weigt of te system: 21 lbs per linear foot, side guides: 6 lbs per linear foot Drop lengt Stoebic Fire & Smoke Fabric E.6' - 20' 26' 7.87'' 8.66'' Stoebic Fire & Smoke Fabric E.6' - 2' 16' 7.87'' 8.66'' Stoebic Fire & Smoke Fabric H.6' - 1' 16' 7.87'' 8.66'' Stoebic Fire & Smoke Fabric H.6' - 16' 1' 7.87'' 8.66'' Stoebic Fire & Smoke Fabric H.6' - 20' 10' 7.87'' 8.66'' Oter configurations and special design on request Widt-to-drop-lengt ratio: max. 1:.15" 1" Bottom bar 1".15" 14

15 Range of ousings Bottom bars Installation to te ceiling Installation to te all Wit self-leveling bottom bar (optional) 1.5" Standard design 1.5" Self-leveling bottom bar (optional).1 "." 2.4" 2.4" 2.4" 2.8" 1." 1." Alternatives for te installation Range of side guides Installation of te ousing to te all, front site run Installation of te ousing to te all, false ceiling is attaced to te ousing on one side, front site run.1" type 80 K type 80 KB type 80 KN Protection targets Integrity Integrity it limitation of eat transmission Insulation it intensified sprinkler protection Installation of te ousing directly to te ceiling Installation of te ousing directly to te ceiling, false ceiling is attaced to te ousing on bot sides Classification Fabric 2 ours fire rating (UL 10D) 20 minutes fire rating (UL 10B, UL 10C, NFPA 252) Stoebic Fire & Smoke Fabric E EW 90 Stoebic Fire & Smoke Fabric H EI 120 Stoebic Fire & Smoke Fabric E Test standard / certificate UL 10B, UL 10C, UL10D UL 864, UL 1784, NFPA 252 OSHPD CA Test report OPA UB III/B UB III/B Installation of te ousing to te ceiling by using angers Installation of te ousing to te ceiling by using angers, false ceiling is attaced to te ousing on bot sides Water irrigation 20" 2" 20" 15

16 Textile fire protection closure for openings in facades, installation inside a building and for small all openings System description 2 ours fire rating according to system idt up to 1' (it small drop lengts) textile fire protection closure for standard indo openings (metal indos require Stoebic Fire Fabric E, ooden or plastic indos require Stoebic Fire Fabric H) cost saving solution by a manual re-opening, drive unit (optional) soft bottom bar (to fulfill industrial safety requirements) termomecanical release, release by fire detection elements (optional) drive unit by a and eel respectively exagon nut, crank andle (optional) drop lengt of max..' by prevention of a flame flasover over te balustrade Fabric System idt Drop lengt Installation dimension System idt Stoebic Fire Fabric E 1.6' 1.6' 5.1'' 5.51'' Stoebic Fire Fabric E 4.9' 6.6' 5.1'' 5.51'' Stoebic Fire Fabric E 5.9' 5.9' 5.1'' 5.51'' Stoebic Fire Fabric E 7.5'.' 5.1'' 5.51'' Stoebic Fire Fabric E 1.1'.' 5.1'' 5.51'' Stoebic Fire Fabric H 1.6' 1.6' 5.1'' 5.51'' Stoebic Fire Fabric H 4.9' 4.6' 5.1'' 5.51'' Stoebic Fire Fabric H 5.9' 4.6' 5.1'' 5.51'' Stoebic Fire Fabric H 7.5'.' 5.1'' 5.51'' Stoebic Fire Fabric H 1.1'.' 5.1'' 5.51'' Oter configurations and special design on request Weigt of te system: 14 lbs per linear foot, side guides: 4 lbs per linear foot Building sell opening 16

17 Housings Bottom bar Termomecanical (standard) Electromecanical (special) Side guide.5" Protection targets 2" Integrity Integrity it limitation of eat transmission Insulation it intensified sprinkler protection 2.6" Classification 2 ours fire rating EW 0 ( classification) EI 120 ( classification) Fabric Stoebic Fire Fabric E Stoebic Fire Fabric H Stoebic Fire Fabric E Test standard / certificate UL 864, Test report UB III/B UB III/B Water irrigation 2" 20" 20" 17

18 Textile fire protection closure for openings in facades and installation outside a building System description 2 ours fire rating according to special design for te application under climatic influence ig variability for installations in facades (noninsulated facades, insulated facades, it combustible or noncombustible insulation) temperature control to avoid te icing of te side guides safe drive unit, ic guarantee a safe closing even in case of lo temperatures proven components for te application outside of a building drive unit it fail-safe tecnology (closing itout auxiliary poer) 10 years outdoor eatering test System idt Weigt of te system: 22 lbs per linear foot, side guides: 1 lbs per linear foot Fixed bearing Side guide Drop lengt a 1" Bottom bar 1" a a = Dimension for te side guide Fabric System idt Drop lengt Stoebic Fire Fabric H 2.6' ' 6.6' 7.48'' 9.84'' Stoebic Fire Fabric H 2.6' ' 16.4' 9.25'' 11.4" Stoebic Fire Fabric P 2.6' - 5.2' 11.5' 7.48'' 9.84'' Stoebic Fire Fabric P 5.2' ' 11.5' 7.48'' 7.87'' Stoebic Fire Fabric P 2.6' ' 11.5' ' 7.48'' 9.84'' Oter configurations and special design on request Widt-to-drop-lengt ratio: max. 1: 18

19 Installation of ousings Bottom bars Witout insulation Wit noncombustible insulation Installation of side guides Wit combustible insulation (Alternative solutions are possible in case of closing onto noncombustible materials) 2.9" -.9" 4.1" - 6." Witout insulation Protection targets Integrity Integrity it limitation of eat transmission Prevention of flasover from floor to floor 2.9" -.9" 4.1" - 6." 4' ¹¹/₁₆" Wit noncombustible insulation Classification 2 ours fire rating EW 90 ( classification) 2 ours fire rating Fabric Stoebic Fire Fabric P Stoebic Fire Fabric H Stoebic Fire Fabric P 4.1" - 6." 2.9" -.9" Test standard / certificate UL 864, Test report GU IV/97-7 UB III/B B Wit combustible insulation 19

20 System description 0 min. insulation according to system idt up to 20' and a drop lengt up to 1' single-layer sealing less space requirements of te ousing simple mounting on te all dry system (no sprinkler necessary) drive unit it fail-safe tecnology (closing itout auxiliary poer) emergency opening it battery backup (optional) surveillance of closing edgings and areas (optional) System idt Drop lengt 20' 10' 20.08'' 15.75'' 20' 1' 22.64'' 17.72'' Range of ousings Oter configurations and special design on request System idt Wit casing Witout casing Drive options 8.7'' Weigt of te system: 68 lbs per linear foot, side guides: 14 lbs per linear foot Opening idt Clearance idt Standard version: space requirement for installation = opening idt " Special construction: space requirement for installation = opening idt + 21." Drop lengt Side guide Wit cain drive Protection target Classification Test standard / certificate Wit tubular motor Integrity and insulation 0 min. fire rating 0 min. insulation UL 864, Test report 2200/11/15 469/11/14 20

21 Insulating textile fire protection closure itout sprinkler System description 60 min. insulation according to system idt up to 20' and a drop lengt up to 1' double-layer sealing less space requirements of te ousing simple mounting on te all dry system (no sprinkler necessary) drive unit it fail-safe tecnology (closing itout auxiliary poer) emergency opening it battery backup (optional) surveillance of closing edgings and areas (optional) System idt Drop lengt 20' 10' 25.98'' 22.05'' 20' 1' 28.94" 25.59'' Oter configurations and special design on request Range of ousings System idt Weigt of te system: 120 lbs per linear foot, side guides: 14 lbs per linear foot Drop lengt Wit ousing Protection target Classification Witout ousing Integrity and insulation 60 min. fire rating 60 min. insulation Opening idt Side guide Test standard / certificate UL 864, Clearance idt Test report 004/878/09 267/864/11 Standard version: space requirement for installation = opening idt + 1.5" Special construction: space requirement for installation = opening idt + 2.6" 21

22 Stoebic Fire Curtain V Te only Fire Curtain itout side guides System description 90 min. insulation and 120 min. fire rating according to system idt up to 9' and a drop lengt up to 12' multi-camber construction no side guides (embrasure is used as guidance) lateral system overlapping 6.9" drive unit it fail-safe tecnology (closing itout auxiliary poer) flexible stop system (accurate top position) lo casing slide and roller elements for all protection (no scratcing on te all en opening and closing) bottom tray it optical design possibilities (optional) Wit ousing In suspended ceiling itout ousing Calculation formula Calculation of te clear eigt = 0.84 x opening eigt Some examples Clear eigt Opening eigt ₁ b 82.09" 98.4" 22.64" 16.4" 20.87" 16.4" 98.4" " 22.64" 19.69" 24.21" 16.4" " " 22.64'' 2.68" 7.20" 16.4" Oter configurations and special design on request Suspended ceiling Wit ousing In suspended ceiling itout ousing ₁ Opening eigt Weigt of te system: 61lbs per linear foot Clear eigt Opening idt System idt b 22

23 Installation of ousings Installation of te ousing directly to te all Installation of te ousing directly to te all, false ceiling is attaced to te ousing on bot sides Installation of te ousing directly to te ceiling Design of bottom tray Standard, tree-part, paint coated Installation of ligtings Bottom side coated Design of embrasure Lateral connection 11.22" 10.04" Protection target 6.89" Integrity and insulation fire detector Wall protection Classification 120 min. fire rating 90 min. insulation Test standard / certificate UL 864, Mitlaufender Wandscutz - unsictbar bei geöffnetem System Test report UB./ Revolving all protection invisible en system is open 2

24 Tigt fire protection closure for ig pressure and smoke protection System description 2 ours fire rating according to system idt up to ' and a drop lengt up to 20' (Stoebic Fire & Smoke Fabric E) additional tigt smoke protection (passive sealing system it noncombustible sealing parts) elastic floor sealing to seal bigger unevenness versatile mounting options drive unit it fail-safe tecnology (closing itout auxiliary poer) drive unit it 10,000 cycles different protection targets (E, EW) by using different types of fabrics ig quality fabric it silicone coating or it polyuretane coating safety edge (optional) Fabric System idt Drop lengt Housing Housing 11.22" x 7.87" exclusively for ceiling mounting Stoebic Smoke Fabric E ' 20' 1.78" 10.24" standard Stoebic Smoke Fabric E 16' 15' 11.22" 7.87" special Stoebic Smoke Fabric E 11' 11' 7.48" 11.42" special Stoebic Smoke Fabric E 2' 16' 11.42" 14.17" special Stoebic Smoke Fabric H 2' 10.5' 1.78" 10.24" standard Stoebic Smoke Fabric H 16' 8.2' 11.22" 7.87" special Stoebic Smoke Fabric H 11' 6,6' 7.48" 11.42" special Stoebic Smoke Fabric H 20' 9.8' 11.42" 14.17" special Oter configurations and special design on request System idt Weigt of te system: 40 lbs per linear foot, side guides: 8 lbs per linearfoot Drop lengt Standard ousing Special ousing 24

25 Range of ousings Bottom bars Installation of side guides 2.91" 2.91" 2.91" 4.09" 4.09" 4.09" Standard ousing Standard ousing Special ousing Standard Standard Wit Wit safety safety edge edge Installation to te all Alternatives for te installation Installation to te embrasure Installation to te nice Installation of te ousing to te all Mounting options Installation of te ousing to te all; false ceiling is unilaterally connected to te ousing Installation of te ousing directly to te ceiling Installation of te Installation of te Installation of te ousing Installation directly to te to te all ousing Installation over a in te embrasure ousing Installation over a in te nice ceiling, false ceiling suspension to te suspension to te is connected to te ceiling ceiling, false ceiling ousing on bot sides is connected to te ousing on bot sides itout fire protection Mounting on bricking Mounting on concrete Mounting on ood Mounting on ligt-eigt all Protection targets Integrity Integrity it limitation of eat transmission Insulation it intensified sprinkler protection Classification 2 ours fire rating, s₂₀₀ EW 90, s₂₀₀ EI 120, s₂₀₀ Fabric Stoebic Fire Fabric P Stoebic Fire Fabric E Stoebic Fire Fabric H Stoebic Fire Fabric P Stoebic Fire Fabric E Test standard / certificate UL 864,, EN 164-, EN 164-, EN 164- Test report UB III/B UB III/B UB III/B UB III/B

26 Control units Variable control of te smoke/fire curtains by release of te detection loop according to UL 864 RZ 7, RZ 8, AM-U Central fire monitoring detection line 4 pus button, red 1 release signal provided from site 1 Stoebic fire protection central RZ 7, RZ 8 AM-U RZ7 can control up to 10 AM-U and 10 motors it a standard old-open-time of 45 minutes (standard old open time can be expand) RZ8 can control up to 2 AM-U and 2 motors it a standard old-open- time of minutes (standard old-open-time can be expand) tubular motor Dimensions of te systems: RZ7 = 16 inc x 5 inc x 16 inc (idt x eigt x lengt) RZ8 = 12 inc x 5 inc x 12 inc (idt x eigt x lengt) AM-U = 11 inc x inc x 6 inc (idt x eigt x lengt) release fire compartment BA 1 Central 1 release fire compartment BA 2 fire monitoring release fire compartment BA 1 1 Variable control of te smoke curtains by release of te detection loop Stoebic MC/REL Evaluation unit 2xx AM-U AM-U AM-U Logic via ardare possible up to detector groups 2x 2x AM-U AM-U tubular motor tubular motor tubular motor smoke section 1 2x 2x AM-U AM-U tubular motor tubular motor tubular motor smoke section 2 AM-U 2x AM-U 2x tubular motor tubular motor tubular motor smoke section Variable control of te smoke barriers by a release signal from te detection loop release fire compartment BA 1 release fire compartment BA 2 Central fire release fire compartment BA monitoring release fire compartment BA 4 Possible for up to 16 release groups AM-U / RS 5 AM-U / RS 5 AM-U / RS 5 AM-U / RS 5 RZ7 - OP smoke section 1 smoke section 2 smoke section smoke section 4 smoke section 5 smoke section 6 Logic via CAN-BUS is free programmable for up to 16 detector groups Controlled, motor-driven re-opening despite of fire alarm detection line 4 Re-opening of te smoke curtains for te firefigting and evacuation fire protection central RZ central fire alarm system 1 AM-U RS 2 tubular motor safe poer supply 1 detection line 4 Re-opening of te smoke curtains for a sort time opening of te escape route fire protection central RZ central fire alarm system pus button for manual re-opening timer defines te old-open time 1 1 AM-U RS 2 tubular motor safe poer supply caption: 1 = Ölflex G0, 0,01 ft 2 2 = NHXH-J E90 x 0,02 ft 2 RE it function preservation = system cable, pluggable / Stoebic 4 = J-Y(St)Y-2 x 2 x 0,01 ft 2 5 = BUS cable J-Y(St)Y-2 x 2 x 0,01 ft 2 Tubular motor Intelligent electronic position sensor tecnology Fail-safe tecnology Certified locking device VAC drive motor it gear box

27 Installation situations Installation of te casing to te all, from beind Installation of te casing to te all, from te front Installation of te casing to te all, loer part of te casing is flus on one side it te casing, from belo Installation of te casing to te all, loer part of te casing is flus on one side it te casing, from belo Design for te steel components Coated Galvanised Stainless steel Polised Circle matt Grinded K 240 finised Installation of te casing directly to te ceiling, from beind/from belo Installation of te casing directly to te ceiling, loer part of te ceiling is flus on bot sides it te casing, from belo Installation of te casing by suspensions to te ceiling, from beind/from belo Fabric - fire beaviour Standard of te fabric: ASTM E84 For te folloing fabrics: Stoebic Fire & Smoke Fabric P Stoebic Fire & Smoke Fabric E Installation of te casing by suspensions to te ceiling, from beind/from belo Selection of fabrics for fire curtains Stoebic Fire & Smoke Fabric P Stoebic Fire & Smoke Fabric E Stoebic Fire & Smoke Fabric H

28 Our innovation and passion as brougt... Since 1980 Stoebic Brandscutz GmbH as developed specialized separation tecnologies able to resist te effects of smoke and fire. Eleven of tese are internationally recognized innovations and orld novelties. References 1980 FIRST CONVEYOR SYSTEM 1996FIRST FIRE CURTAIN 199 FIRST SMOKE CURTAIN EXPERIENCED TRENDSETTER 11 orld novelties and over 5 years of researc, production and installations trougout te orld ave made us specialists for your protection! We are te most experienced and most innovative company in te market - Stoebic te Original! UNTIL 2016 BASED IN CHARLESTON, SC THROUGHOUT THE USA AND CANADA Based in Carleston, SC and trougout our Nort American distributor netork e provide ig quality fire protection based on German engineering. No iger accolade tan being imitated,... but never accomplised Stoebic Fire & Smoke Protection Innovation for your Protection! Stoebic Fire Protection Systems LP 1941 Savage Road / Suite 200 B Carleston SC / United States Office Service info@stoebic.us,.stoebic.us FSA-US-M-000

Case Study: Cabinet Cooling Using a Water and Refrigeration System C m C /

Case Study: Cabinet Cooling Using a Water and Refrigeration System C m C / Case Study: Cabinet Cooling Using a Water and Refrigeration System Escalating computing capabilities and srinking cip packages are leading to corresponding increases in server and rack poer densities.

More information

New GuideLed safety luminaires

New GuideLed safety luminaires CEAG GuideLed safety luminaires New GuideLed safety luminaires Linear design combined wit ig economy GuideLed SL 111.1, 121.1 CG-S Recessed mounting EN 1838 LED * GuideLed SL 111.1 CG-S IP1 GuideLed SL

More information

CHESNEY S. The Bio Ethanol Collection

CHESNEY S. The Bio Ethanol Collection CHESNEY S Te Bio Etanol Collection Cesney s Bio Etanol Fires Sometimes it isn t possible to install a orking fire. Tere may be problems it te cimney or no provision for a orking fireplace. A fire from

More information

Technical System Catalogue Chillers for IT cooling

Technical System Catalogue Chillers for IT cooling Tecnical System Catalogue Cillers for IT cooling Cillers for IT cooling Te Rittal IT ciller in conjunction wit free cooling supplies exceptionally energy- and cost-efficient IT cooling media. Te system

More information

MOBA-MATIC AND BIG SONIC-SKI. LEVELING to THE HIGHEST STANDARD

MOBA-MATIC AND BIG SONIC-SKI. LEVELING to THE HIGHEST STANDARD MOBA-MATIC AND BIG SONIC-SKI LEVELING to THE HIGHEST STANDARD MOBA-MATIC THE MOST VERSATILE CONTROL SYSTEM in te world Weter ultrasonic sensor, laser or rotary sensor, MOBA-matic te most flexible control

More information

Technical data Chimney fans, controllers & accessories

Technical data Chimney fans, controllers & accessories Tecnical data Cimney fans, controllers & accessories y Solid fuel and wood-burning stoves and fireplaces y Biofuel boilers y Decentralised multiple eating appliances connected to same cimney 1 a D W a

More information

Requirements of EN 1838: illuminance of 5 lx for safety equipment

Requirements of EN 1838: illuminance of 5 lx for safety equipment GuideLed SL 151, 152 CG-S Ceiling recessing, ceiling surface-mounting for illuminance of 5 lx vertically Requirements of EN 1838: illuminance of 5 lx for safety equipment Te aim of emergency ligting is

More information

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,

More information

Automatic smoke barriers Supercoil Moducoil Stripecoil Smokeshield-S Fixed smoke barriers Supercoil fix Moducoil fix

Automatic smoke barriers Supercoil Moducoil Stripecoil Smokeshield-S Fixed smoke barriers Supercoil fix Moducoil fix Automatic smoke barriers Supercoil Moducoil Stripecoil Smokeshield-S Fixed smoke barriers Supercoil fix Moducoil fix Certificate for the usability CE-label: A certificate for the usability according to

More information

FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE BRONISLAVA VELTCHEVA

FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE BRONISLAVA VELTCHEVA FIELD STUDY OF THE ROTARY DESICCANT SYSTEM USING THE CROMER CYCLE By BRONISLAVA VELTCHEVA A THESIS PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY OF FLORIDA IN PARTIAL FULFILLMENT OF THE REQUIREMENTS

More information

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures SMART FIRE CURTAINS INTISI7 for invisible fire protection closures 2 INTISI INTISI ı Fire Engineered FABRICS was founded with the aim of being a technological partner for the development and production

More information

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SAC 100 Automatic Smoke Curtain System. - Specifier Information - SAC 100 Automatic Smoke Curtain System - Specifier Information - CONTENTS 1. Introduction Page 3 2. Construction and Method of Operation Page 5 3. Performance 3.1. Resistance to Fire/Heat Page 6 3.2. Deflection

More information

The Compact Automatic Garage Door. HHHHH 5 Star Quality & Service. Is your Garage Door CE Approved? New EU regulation now in force.

The Compact Automatic Garage Door. HHHHH 5 Star Quality & Service. Is your Garage Door CE Approved? New EU regulation now in force. F u l l y A p p r o v e d Is your Garage Door CE Approved? New EU regulation now in force by Warm Protection Products Limited Te Compact Automatic Garage Door HHHHH 5 Star Quality & Service Wen space is

More information

Emergency Lighting Design Guide

Emergency Lighting Design Guide Emergency Ligting Design Guide Step 1 Identify mandatory Points of Empasis for te positioning of luminaires, eamples as follows: FINAL EXIT EXIT SIGNS DIRECTION CHANGE INTERSECTIONS At eac eit door At

More information

Stoebich Conveyor System Closures

Stoebich Conveyor System Closures Stoebich Conveyor System Closures Fire protection for conveyor techniques RGT ECCIos-flex Universal-B ECCIos-S ECCIos-Q ECCIos-D ECCIos-K Ecotube Omnitube Omnicompact Isogate Turbocoil Sleeve Control units

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

luxcontrol lighting control system SWITCH sensors smartswitch HF 5DP f Automatic switching based on motion and light level

luxcontrol lighting control system SWITCH sensors smartswitch HF 5DP f Automatic switching based on motion and light level Automatic switcing base on motion an ligt level Prouct escription Motion etector for luminaire installation Motion etection troug glass an tin materials (except metal) For automatic on/off switcing of

More information

Productive Freeze Dryer

Productive Freeze Dryer Productive Freeze Dryer 1. Freeze-dryer working principle Freeze drying is an advanced metod of deydration,wose process takes advantage of te principle of ice crystal's lyopilization under purified vacuum

More information

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS WHEN IN NEED, CHAMPION DOOR FIRE IS THE ANSWER Champion Door Fire is a domestic specialist solution for properties where doors must conform to fire safety standards.

More information

Air-Conditioners For Building Application Inverter Y-Series OUTDOOR UNIT

Air-Conditioners For Building Application Inverter Y-Series OUTDOOR UNIT ir-onditioners or uilding pplication Inverter Y-Series OUTOOR UNIT PUY-P-YK (-S) or use wit R410 INSTLLTION MNUL or safe and correct use, please read tis installation manual torougly before installing

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM 150 MM TO 750 MM PIPES AND COUPLERS

NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM 150 MM TO 750 MM PIPES AND COUPLERS H A P A S Naylor Drainage Ltd Cloug Green Cawtorne Barnsley Sout Yorksire S75 4AD Tel: 01226 790591 Fax: 01226 791531 e-mail: sales@naylor.co.uk website: www.naylor.co.uk NAYLOR METRODRAIN TWINWALL HIGHWAY

More information

SOLAR HUB RADIATOR. Patented high-efficiency heat pump direct exchange refrigerant / water to produce heating and DHW circuit with integrated solar

SOLAR HUB RADIATOR. Patented high-efficiency heat pump direct exchange refrigerant / water to produce heating and DHW circuit with integrated solar Standard components UB RADIATOR SOAR R SOAR 125 R SOAR 300 Solar collector SEECTIVE 2,0 Solar station UNIT-2 2/12 Solar controller CONTRO MUTI Single support solar collector double support solar collector

More information

The Exploration on the Energy Saving Potential of an Innovative. Dual-temperature Air Conditioner and the Mechanism of the

The Exploration on the Energy Saving Potential of an Innovative. Dual-temperature Air Conditioner and the Mechanism of the Te Exploration on te Energy Saving Potential of an Innovative Dual-temperature Air Conditioner and te Mecanism of te Teoretical Mixed Refrigeration Cycle Zao Lei, Zao Xijin, Hu Andu Professor, graduate

More information

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening

More information

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass Fire Protection Fire-resistant glasses Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass Fire Protection and Aesthetic Design A Range of Remarkable Fire Resistance and

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 SECTION 08 33 23 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer

Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer Modelling of Specific Moisture Extraction Rate and Leakage Ratio in a Condensing Tumble Dryer Lena Stawreberg, Lars Nilsson To cite tis version: Lena Stawreberg, Lars Nilsson. Modelling of Specific Moisture

More information

F, T, L and W Ratings - What are the Code & Testing Requirements?

F, T, L and W Ratings - What are the Code & Testing Requirements? F, T, L and W Ratings - What are the Code & Testing Requirements? Rich Walke Underwriters Laboratories Inc. April 27, 2010 Copyright 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion

More information

ACTIVE FIRE CURTAINS INTISI7

ACTIVE FIRE CURTAINS INTISI7 ACTIVE FIRE CURTAINS INTISI7 For invisible fire partitions www.intisigroup.com Fire Engineered Fabrics How can anyone perfect anything? What does engineering require? From which approach we start???? INTISI

More information

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS Coiling Fire Doors Firemiser Insulated Fire Doors SmokeShield Fire Doors SmokeShield Firemiser Doors Coiling Counter Fire Doors SmokeShield Counter

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 SECTION 08331 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM

PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM THERMAL SCIENCE: Year 0, Vol., No., pp. -4 PERFORMANCE IMPROVEMENT POTENTIALS OF LOW GLOBAL WARMING POTENTIAL REFRIGERANTS FOR INTERCITY BUS AIR CONDITIONING SYSTEM Saban UNAL a, Cagri KUTLU a, and M.

More information

BASEMENT LAYOUT SPRINKLER HEAT DETECTOR SMOKE DETECTOR

BASEMENT LAYOUT SPRINKLER HEAT DETECTOR SMOKE DETECTOR EXAUST EXAUST DN AC PLANT IS A DEVICE TAT DETECTS SMOKE, TYPICALLY AS AN INDICATOR OF FIRE. COMMERCIAL, INDUSTRIAL, AND MASS RESIDENTIAL DEVICES ISSUE A SIGNAL TO A FIRE ALARM SYSTEM, ILE OUSEOLD DETECTORS,

More information

Smoke and Fire Curtains

Smoke and Fire Curtains Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 600 REV. 3 SPECIFICATION Smoke Guard, Inc 287 Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER SECTION 08 3493 AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Smoke detector-activated, vertical closing fire barrier conveyor system closure.

More information

FIRE/SMOKE BARRIER FUNDAMENTALS

FIRE/SMOKE BARRIER FUNDAMENTALS FIRE/SMOKE BARRIER FUNDAMENTALS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com Expertly Engineering Safety From Fire OBJECTIVE Identify the different

More information

Textile fire protection closures EI 30/90

Textile fire protection closures EI 30/90 Textile fire protection closures EI 30/90 Hidden Shield EI 30 Hidden Shield EI 90 10. World Novelty and this has already been awarded! Double / two-sided fire protectionroller shutter construction > EI60

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information

Opteon XP10. Opteon XP10 Retrofit Guidelines to Replace R-134a. Refrigerant. Introduction. Important Safety Information Opteon XP10 Opteon XP10 Retrofit Guidelines to Replace R-134a Introduction Opteon XP10 is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant developed to replace R-134a in medium-temperature

More information

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 400 SPECIFICATION Smoke Guard, Inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.376.1600 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. Refrigerant. Introduction. Important Safety Information Opteon XP40 Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507 Introduction Opteon XP40 is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant developed as a direct replacement

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 200 SPECIFICATION Smoke Guard inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A. Refrigerant (R-449A) Introduction. Important Safety Information

Opteon XP40. Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A. Refrigerant (R-449A) Introduction. Important Safety Information Opteon XP40 (R-449A) Opteon XP40 Retrofit Guidelines to Replace R-402A (HP80) and R-408A Introduction Opteon XP40 (R-449A) is a low global warming potential (GWP) ydrofluoro-olefin (HFO)-based refrigerant

More information

ATTACK INSTRUCTION FOR USE EKO, PLQ, KLQ, KLV, E, EZ, P CAST IRON FLOOR STANDING GAS BOILER

ATTACK INSTRUCTION FOR USE EKO, PLQ, KLQ, KLV, E, EZ, P CAST IRON FLOOR STANDING GAS BOILER ATTACK CAST RON FLOOR STANDNG GAS BOLER EKO, PLQ, KLQ, KLV, E, EZ, P NSTRUCTON FOR USE W W W. A T T A C K. S K Putting te boiler into operation: ATTACK EKO, PLQ, KLQ, KLV, E, EZ, P Capacity of 9, 12, 15,

More information

SPE Logo Quick Use Guide

SPE Logo Quick Use Guide SPE Logo Quick Use Guide Print & Digital Tis guide as been created to elp you get up to speed quickly on te logo formats permitted and most important usage rules tat govern te SPE logo. For more information,

More information

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS SECTION 08 33 23 OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS) FIREIRE CURTAINSURTAINS Approved for use for 30m wide x 10m drop in accordance with AS1530.4 and AS1905.2 KEY FEATURES Fire tested in accordance with AS1530.4 (Up to 2 hours) GENERAL Fibershield automatic

More information

SECTION Overhead Coiling Doors

SECTION Overhead Coiling Doors SECTION 08 33 00 Overhead Coiling Doors To display hidden notes to specifier, select tools/ options/ view/ hidden text. GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1136 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International

More information

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd Smoke and Fire Curtains Performance Door sets for security and Fire resistant applications Introduction The Fire & Smoke curtains are the latest in fire protection systems to be added to the Doors (UK)

More information

Note: Principal version Correction Modification Consolidated version from October Bachelor s Programme in Architecture

Note: Principal version Correction Modification Consolidated version from October Bachelor s Programme in Architecture Note: Te following curriculum is a consolidated version. It is legally non-binding and for informational purposes only. Te legally binding versions are found in te respective issues of te University of

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE PUMP REVIEW Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;

More information

Theoretical and Experimental Analysis of Desiccant Wheel Performance for Low Humidity Drying System

Theoretical and Experimental Analysis of Desiccant Wheel Performance for Low Humidity Drying System Recent Researces Power Systems and Systems Science eoretical and Analysis of Desiccant Weel Performance for Low Humidity Dryg System RI SUYONO, SOHIF MA, MUHAMMAD YAHYA, MUHD. HAFIZ RUSLAN, AZAMI ZAHARIM

More information

Operation Manual Multiparameter Transmitter M400

Operation Manual Multiparameter Transmitter M400 Operation Manual Multiparameter Transmitter M400 Transmitter Multiparameter M400 52 121 378 Transmitter M400 2 Transmitter M400 3 Operation Manual Multiparameter Transmitter M400 Transmitter M400 4 Content

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h DETECTION AREA Active Infrared Sensor OA-EDGE1/EDGE Recommended installation position Leading edge d3 w Pivot edge W Door widt Mounting eigt / d Detection area widt d3 Distance from te leading edge to

More information

CH*/OH* CHEMILUMINESCENCE RESPONSE OF AN ATMOSPHERIC PREMIXED FLAME UNDER VARYING OPERATING CONDITIONS

CH*/OH* CHEMILUMINESCENCE RESPONSE OF AN ATMOSPHERIC PREMIXED FLAME UNDER VARYING OPERATING CONDITIONS Proceedings of ASME Turbo Expo 1: Power for Land, Sea and Air GT1 June 1-18, 1, Glasgow, UK Proceedings of ASME Turbo Expo 1: Power for Land, Sea and Air GT1 June 1-1, 1, Glasgow, UK GT1- GT1-3135 CH*/OH*

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply

More information

MESURED PARAMETERS Parameters Measuring units Identification Symbols

MESURED PARAMETERS Parameters Measuring units Identification Symbols INSTRUCTION MNUL IM425-U v3.1 EMM-R3-V EMM-µ3-V MULTIFUNCTION VOLT/MMETER GENERL Te digital Multifunction Volt/mmeter series EMM-V allow monitoring te main electrical parameters present on a distribution

More information

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: SMOKESHIELD S AUTOMATIC OVERHEAD PERIMETER TYPE FABRIC SMOKE CURTAIN PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire alarm or smoke detector-activated, overhead coiling fabric

More information

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK

More information

INSTALLATION MANUAL. System air conditioner RWEYQ8PY1 RWEYQ10PY1* RWEYQ16PY1 RWEYQ18PY1 RWEYQ20PY1* RWEYQ24PY1 RWEYQ26PY1 RWEYQ28PY1 RWEYQ30PY1*

INSTALLATION MANUAL. System air conditioner RWEYQ8PY1 RWEYQ10PY1* RWEYQ16PY1 RWEYQ18PY1 RWEYQ20PY1* RWEYQ24PY1 RWEYQ26PY1 RWEYQ28PY1 RWEYQ30PY1* INSTALLATION MANUAL System air conditioner Installation manual VRVWIII System air conditioner Englis Installationsanweisung VRVWIII System Klimaanlage Deutsc Manuel d installation Conditionneur d air VRVWIII

More information

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window

More information

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm. DESIGN GUIDE B U I L T- I N S E R I E S F L U S IN S E T O V E R L A Y EFFECTIVE 1/4/2017 TA B L E O F C O N T E N T S 3 B U I L T- I N R E F R I G E R A T I O N F L U S I N S E T O V E R L AY I N S TA

More information

fire protection glass

fire protection glass fire protection glass ABOUT Buildings increasingly require greater features, both in terms of services and protection, not to mention aesthetics and design. In contemporary architecture, glass is one of

More information

Manual. Industrial Air Curtain Model IF. English. Version 1.1

Manual. Industrial Air Curtain Model IF. English. Version 1.1 Manual Industrial Air Curtain Model IF Version 1.1 Q 27-06-2007 English B Copyright All the information and draings in this manual are the property of Biddle and may not be used (other than for the actual

More information

KEEP THE FIRE FROM SPREADING

KEEP THE FIRE FROM SPREADING KEEP THE FIRE FROM SPREADING Fire might be a symbol of man s development in the world, but when it is out of control it could cause enormous damage to the surroundings. Especially when it comes to fire

More information

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

1 P a g e w w w. s m o k e c o n t r o l. c o. nz PROPRIETARY ITEM: FIBERHSIELD EI60 AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire alarm or smoke detector-activated, overhead coiling fabric

More information

fire protection glass

fire protection glass fire protection glass ABOUT Buildings increasingly require greater features, both in terms of services and protection, not to mention aesthetics and design. In contemporary architecture, glass is one of

More information

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC 262-945-4567 Lauzon.lsc@gmail.com Web: Lauzon-LSC.com 1 Wis Professional Engineer Experienced Facility Director Experienced AHJ WHEA Code

More information

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials AMCA International Design Tips For Fire and Smoke Barriers William E. Koffel, P.E., FSFPE President, Koffel Associates, Inc. www.koffel.com Air System Engineering & Technology (ASET) Conference US San

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

MF-RHT Series - High Temperature PTC Resettable Fuses

MF-RHT Series - High Temperature PTC Resettable Fuses *RoHS COMPLINT, **HLOGEN FREE & EC COMPLINT RH750 7180S Features n Compliant wit EC-Q200 Rev-C- Stress Test Qualification for Passive Components in utomotive pplications n Operating temperature range up

More information

EXCELSIOR FIRE DISTRICT

EXCELSIOR FIRE DISTRICT EXCELSIOR FIRE DISTRICT Minnesota State Fire Code and the Excelsior Fire District Inspection Fire Safety & Code Requirements TENTS OVER 200 SQUARE FEET The following codes set fourth by the Minnesota State

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter

More information

Air-Conditioners PKA-RP FAL INSTALLATION MANUAL. English

Air-Conditioners PKA-RP FAL INSTALLATION MANUAL. English ir-onditioners PK-RP FL INSTLLTION MNUL FOR INSTLLR For safe and correct use, please read tis installation manual torougly before installing te air-conditioner unit. nglis ontents. Safety precautions....

More information

No Risk! Data Sheet Secura Series - Sartorius weegschalen

No Risk! Data Sheet Secura Series - Sartorius weegschalen Data Seet Secura Series - Sartorius weegscalen Geavanceerde balansen die zijn gemaakt voor betrouwbare en veilige weegandelingen voor gebieden waarvoor regelgeving geldt. No Risk! Laboratory Balances Blocked

More information

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS Honeywell Thermal Solutions Family of Offerings: 1 Product Brands: Becomes Becomes Becomes Hauck Exothermics Combustion Safety*

More information

designed for rail 5000 Series

designed for rail 5000 Series designed for rail 5000 Series 5000 Series The only complete SIL system 20 years of experience in the field. More than 15.000 systems supplied worldwide. A team devoted to rolling stock projects with specialized

More information

Fire and Security Products and Services

Fire and Security Products and Services * www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted

More information

Schueco Fire and Smoke Protection Systems

Schueco Fire and Smoke Protection Systems Schueco Fire and Smoke Protection Systems Green Technology for the Blue Planet Clean Energy from Solar and Windows 02 Schueco Fire and Smoke Protection Systems Fire and Smoke Protection Systems Schueco

More information

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015

More information

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems FEMA Recommendations are based upon Live Fire Testing of Prep Stations

More information

Module 7. Control of Smoke & Highlights of Code Requirements

Module 7. Control of Smoke & Highlights of Code Requirements Module 7 Control of Smoke & Highlights of Code Requirements 1 Module 7 Overview This module will cover: 1. The requirements of smoke control in the Ohio Building Code Section 909 2. The differences between

More information

Fire Rated Door Assemblies: Compliant Designs

Fire Rated Door Assemblies: Compliant Designs Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported

More information

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question. Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy

More information

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS Last Updated: April 28, 2008 FIRE REGULATIONS The purpose of fire regulations is to maintain an acceptable level of fire safety within CGS facilities.

More information

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S Fire Safety By Design O N L Y T H E W O N - D O O R F I R E G U A R D C A N cover wide spans* heights up to

More information

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd B Directories B.1 Keyword Directory...326 B.2 Tables...329 B.3 Figures...330 B.4 End Notes...332 325 B.1 Keyword Directory A addressing (collective) 93, 125 addressing (individual) 93 aerosol 69, 70, 95

More information

H gh-p led Combust ble Storage. Application Guide 2009 Edition

H gh-p led Combust ble Storage. Application Guide 2009 Edition H gh-p led Combust ble Storage Application Guide 2009 Edition Table of Contents Preface... v About the International Code Council... vi About the Author... vii Acknowledgements... ix Chapter 1 Introduction

More information

Report on Public Input June 2014 NFPA 101

Report on Public Input June 2014 NFPA 101 101 PI# 115 SAF-FUR (10.2.1.2) 10.2.1.2 Materials applied directly to the surface of walls and ceilings in a total thickness of less than 1 / 28 in. (0.9 mm) shall not be considered interior finish and

More information