GUF-RD3 GUF-RDH3. OA Processing unit CONTENTS. OA Processing unit R410A
|
|
- Harry Thornton
- 5 years ago
- Views:
Transcription
1 OTETS GUF-RD3 GUF-RDH3. Specifications Sound evels oise levels Fan characteristics curves External Dimension Wiring Diagrams - -
2 . Specifications Item Power supply urrent Input ooling capacity Heating capacity Fan Type o. ir volume External static pressure oise level Humidifying capacity ladding Height Dimensions Width Depth Weight (drying) Motor - ir filter Supply air Exhaust air Total heat exchanger (ossnay element) Direct expansion heat exchanger coil Humidifying Refrigerant pipe dimension Gas iquid Model W kw kw m 3 /h /S Pa d() kg/h mm mm mm kg ø mm ø mm GUF-RDH <.66> 6.42<2.2> GUF-RDH3 GUF-RD3 Single phase 2-2V ~Hz <3.49>.29<.66> 3.<4.> 6.42<2.2> S : entrifugal fan [Sirocco fan] E : entrifugal fan [Sirocco fan] Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 units on-woven fabrics filter : Gravitational method 82% +High efficiency filter : olorimetric method 6% (optional parts) on-woven fabrics filter : Gravitational method 82% Partition, spacing plate-special treated paper luminum plate fins and copper tubes Permeable film humidifier Drain pipe dimension VP2 apacity equivalent to the indoor unit P32 P63 P32 P63 ote: 2 The figures in < > indicates the heat recovery at ossnay element. ooling/heating capacity indicates the maximum value at operation under the following condition. ooling : Indoor : 27 D/9. W Outdoor : 3 D/24 W Heating : Indoor : 2 D/4.6 W Outdoor : 7 D/6 W 3 The values given in the table for the noise level reflect the levels measured at a position. meters immediately below the unit in anechoic chamber. 4 The noise at the air outlets (at a 4 angel,. meters in front) is about -6 d() higher than the values given in the table. 6 The above values apply during ossnay ventilation when the fan speed is set to high speed. Specification may be subject to change without notice. It is measured in anechoic room Galvanized steel plate GUF-RD <3.49> 3.<4.>
3 2. Sound evels 2. curves GUF-RDH3/RD3 Directly below (Measurement point ) Outlet (Measurement point ) Octave band sound level (d) Overall K 2K 4K 8K Overall K 2K 4K 8K Octave band central frequency (Hz) Octave band central frequency (Hz) Octave band sound level (d) - GUF-RDH3/RD3 Directly below (Measurement point ) Outlet (Measurement point ) Octave band sound level (d) Overall K 2K 4K 8K Overall K 2K 4K 8K Octave band central frequency (Hz) Octave band central frequency (Hz) Octave band sound level (d) Measurement ondition Measurement site: Mitsubishi Electric o., akatsugawa Works nechoic chamber <eiling recessed type> Supply/ Exhaust air Main unit. m To indoor unit. m - 7
4 2.2 Fan characteristics curves Humidifying Type GUF-RDH3 GUF-RDH3 External static pressure(mmh2o) Exchange efficiency(%) External static pressure (Pa) ow efficiency(ooling) High Temperature exchange efficiency efficiency(heating) (m 3 /h) 2 ir volume (/s) mm dia pipe length m m m m m External static pressure(mmh2o) Exchange efficiency(%) External static pressure (Pa) ow efficiency(ooling) Temperature exchange efficiency efficiency(heating) High (m 3 /h) ir volume (/s) mm dia pipe length m m m m m on-humidifying Type GUF-RD3 GUF-RD3 External static pressure(mmh2o) Exchange efficiency(%) External static pressure (Pa) ow efficiency(ooling) High Temperature exchange efficiency efficiency(heating) (m 3 /h) 2 ir volume (/s) mm dia pipe length m m m m m External static pressure(mmh2o) Exchange efficiency(%) External static pressure (Pa) ow efficiency(ooling) Temperature exchange efficiency (m 3 /h) efficiency(heating) High ir volume (/s) mm dia pipe length m m m m m - 8
5 3. External Dimension GUF-, RD(H)3 Unit : mm Humidifying Type GUF-/RDH3 Position where duct direction cange is possible Damper plate ir exhaust fan P eiling suspension fixture E (Exhaust air) R (Return air) Model D E F G H J K GUF-RDH3 74,6 24,8, GUF-RDH3 9,23 49,46, O (Outdoor air) Maintenance space for Heat recovery unit (ossnay ore) ir filters, lower High-efficiency filter or more - Maintenance cover Heat recovery unit (ossnay ore) 79 eiling suspension P fixture G H Inspection opening High efficiency filter (Optional parts) Y ir filters 79 Q W Position where duct direction change is possible Inspection opening V E F ontrol box 79 ir supply fan S (Supply air) Solenoid valve unit with pressure requlator Maintenance space for Heat exchanger Permeable-film humidifier Direct Expansion coil ø R Permeable-film humidifier Maintenance cover(humidifier) ø S Gas pipe (Flare ø T) iquid pipe (Flare ø U) Water intake Drain discharge hole Strainer(R/2 of External thread) (VP2 connection) M J Power supply opening K Model M P Q R S T U V W Y GUF-RDH3 37, GUF-RDH3 398, on-humidifying Type GUF-/RD3 Position where duct direction change is possible Damper plate ir exhaust fan D eiling suspension fixture E (Exhaust air) R (Return air) O (Outdoor air) Maintenance spase for Heat recovery unit (ossnay ore) ir filters, lower High-efficiency filter or more - G Inspection opening Inspection opening E F ir supply fan S (Supply air) Maintenance space for Heat exchanger M J K Maintenance cover H ontrol box Power supply opening Model eiling suspension fixture D E F G H J K Heat recovery unit (ossnay ore) GUF-RD3 74,6 24,8, GUF-RD3 9,23 49,46, P High-efficiency filter (Optional parts) W ir filters Q V 79 Position where duct direction change is possible Direct Expansion coil ø R ø S Maintenance cover(humidifier) Gas pipe (Flare ø T) iquid pipe (Flare ø U) Drain discharge hole (VP2 connection) Model M P Q R S T U V W GUF-RD3 37, GUF-RD3 398,
6 4. Wiring Diagrams Humidifying Type GUF-/RDH3 TM, TM2 shown in dotted lines are field work. e sure to connect the grounding wire. reakers and controller switches should be provided by the customer. GREE/YEOW GREE/YEOW M2 ORGE PIK K SUPPY F GREE/YEOW M GM S W.S TH(O) PIK K UE ORGE EXHUST F SV2 PURPE PURPE SV RSV(k ) TH4(R) TH3 Gas pipe TH2 iquid pipe YEOW ORGE ORGE YEOW YEOW GREY GREY YEOW YEOW PIK PIK ROW PURPE PURPE PIK PIK D ZR9D2 F3 EV ED2 ED SW2 F2 YEOW YEOW K F4 F ORGE X2 ED3 DS + D ROW PURPE ORGE PIK SW4 SW SW2 SW3 D SW4 X6 X7 SW X4 X FUSE ZR 32 D2 3 T 3T 2 SW TR UE ROW ROW X3 ROW UE X8 X9 GREE /YEOW S TM3 TM2 TM PE POWER SUPPY 2-2V ~Hz 2V D 24V REKER(6) Humidistat Uncharged a-contact 2V more than m Operation monitor output MX MI 2V 2V m D 24V D V m Malfunction monitor output MX MI 2V m D V m Remote ontroller <PR-M> M-ET transmission cable To Outdoor Unit, ontroller Fresh Master M-ET Remote controller < PR-F27ME> Shield wire MRK : indicates terminal block, : connector : board insertion connector or fastening connector of control board. Explanation M M2 W.S SV SV2 TH TH2 TH3 TH4 EV RSV ame Fan motor (exhaust) Fan motor (supply) apacitor Water sensor Solenoid valve (pressure regulator) Solenoid valve (exhaust) Thermistor (outdoor air temp. detection) Thermistor (pipe temp. detection/liquid) Thermistor (pipe temp. detection/gas) Thermistor (room air temp. detection) Electronic linear expansion valve Resistance (solenoid valve) TM TM2 TM3 SW SW2 SW3 SW4,SW SW SW2 SW4 32,2 ame Terminal block (power supply) Terminal block (transmission) Terminal block (humidistat, monitor) Switch (function selection) Switch (capacity code setting) Switch (function selection) Switch Switch (st digit address set) Switch (2nd digit address set) Switch (branch O. set) onnecter (Remote input) onnecter (Remote input/output) ame, 2 Remote control terminal, M-ET transmission terminal S Shield D, D2 onnector (power supply) X2-X9 Relay TR Transformer GM Damper motor S imit switch ED Power supply monitor ED2 M Remote contolle Power supply monitor ED3 M-ET Power supply monitor -
7 on-humidifying Type GUF-/RD3 TM, TM2 shown in dotted lines are field work. e sure to connect the grounding wire. reakers and controller switches should be provided by the customer. GREE/YEOW GREE/YEOW M2 ORGE PIK K SUPPY F GREE/YEOW M GM S W.S TH(O) PIK K UE ORGE EXHUST F TH4(R) TH3 Gas pipe TH2 iquid pipe YEOW ORGE ORGE YEOW YEOW GREY GREY YEOW YEOW PIK PIK ROW PURPE PURPE PIK PIK 7 6 ZR9D2 27 4D F3 EV ED2 ED SW2 F2 YEOW YEOW K F4 F ORGE X2 ED3 DS + D ROW PURPE ORGE PIK SW4 SW SW2 SW3 D SW4 X6 X7 SW X4 X FUSE ZR D T 3T SW TR UE 2 ROW ROW X3 ROW UE X8 X9 GREE /YEOW S TM3 TM2 TM PE POWER SUPPY 2-2V ~Hz 2V D 24V REKER(6) Operation monitor output MX MI 2V 2V m D 24V D V m Malfunction monitor output MX MI 2V m D V m Remote ontroller <PR-M> M-ET transmission cable To Outdoor Unit, ontroller Fresh Master M-ET Remote controller < PR-F27ME> Shield wire MRK : indicates terminal block, : connector : board insertion connector or fastening connector of control board. Explanation M M2 W.S TH TH2 TH3 TH4 EV ame Fan motor (exhaust) Fan motor (supply) apacitor Water sensor Thermistor (outdoor air temp. detection) Thermistor (pipe temp. detection/liquid) Thermistor (pipe temp. detection/gas) Thermistor (room air temp. detection) Electronic linear expansion valve TM TM2 TM3 SW SW2 SW3 SW4,SW SW SW2 SW4 32,2 ame Terminal block (power supply) Terminal block (transmission) Terminal block (humidistat, monitor) Switch (function selection) Switch (capacity code setting) Switch (function selection) Switch Switch (st digit address set) Switch (2nd digit address set) Switch (branch O. set) onnecter (Remote input) onnecter (Remote input/output) ame, 2 Remote control terminal, M-ET transmission terminal S Shield D, D2 onnector (power supply) X2-X9 Relay TR Transformer GM Damper motor S imit switch ED Power supply monitor ED2 M Remote contoller Power supply monitor ED3 M-ET Power supply monitor - 6
8 - 62
OA Processing unit GUF-RD4, GUF-RDH4
Processing unit DT G GUFRD4, GUFRDH4 I. Processing unit. SPEIFITIOS... 27 2. SOUD EVES... 28 2. Measurement ondition... 28 22. curves... 28. F HRTERISTIS URVES... 29 4. EXTER DIMESIOS... 240 5. EETRI WIRIG
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationFresh Master. Installation Instructions (For use by dealer/contractor) GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3. Models:
Fresh Master Models: GUF-0RDH GUF-0RD GUF-00RDH GUF-00RD Installation Instructions (For use by dealer/contractor) GUF-0RDH shown above. Contents. Safety precautions... -. Accessories.... Outline drawings....
More information250mm dia straight pipe length SP4 SP3. Air volume
MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material
More informationGUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.
Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the
More informationAir to Air Heat Exchanger
Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications
More informationVentilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF
Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationPUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)
AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh
More informationtechnical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air
technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................
More informationtechnical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air
technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationTECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER
Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)
27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationAir Conditioners. Technical Data FBQ-C
Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor
More informationtechnical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air
technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help
More informationtechnical data air conditioning systems Indoor Units FBQ-C7VEB
technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................
More informationAir Conditioner CONTENTS
ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS
More informationInstallation Instructions
0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation
More informationLOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)
LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E
More informationkw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit
Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationWall-mounted air heaters for outdoor installation MEC EX C
all-mounted air heaters for outdoor installation for ducted outdoor installation wall-mounted air heaters have been specifically designed and certified for outdoor installation. he units are equipped with
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More informationOUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER
DTV_OAE034E_03--CHAPTER01 2015.01.16 CONTENTS 1. FEATURES... A-01 2. SPECIFICATIONS... A-02 3. ELECTRIC CHARACTERISTICS... A-03 4. DIMENSIONS... A-05 5. REFRIGERANT CIRCUIT...A-11 6. WIRING... A-12 6-1.
More informationMitsubishi Electric's
3rd edition CONTENTS What is HYBRID CITY MULTI? - System Structure - 3 The reason why HYBRID CITY MULTI is unbeatable - Features - 4 - pplication example - 8 Mitsubishi Electric's Lineup 9 Specifications
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationTABLE OF CONTENTS RMXS-E8V1B
Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................
More informationLiquid Level Controller
iquid evel Controller Fully Automatic operation enabling both draining and filling simultaneously with a single device Adjustable sensitivity level from 1k to 200k Ohm Includes provision for Manual start
More informationwith a Breath of Fresh Air
ENERGY RECOVERY VENTILATORS MODEL RX4 SERIES Time Spent in Comfort with a Breath of Fresh Air Time Spent in Comfort with a Breath of Fresh Air HD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU,
More informationSERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC
Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.
More informationtechnical data air conditioning systems Indoor Units FCQ-C8VEB
technical data Indoor Units FCQ-C8VEB air conditioning systems technical data Indoor Units FCQ-C8VEB air conditioning systems TABLE OF CONTENTS FCQ-C8VEB! 1 Features.............................................................
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationAIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK
AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...
More informationHeat Recovery Ventilation
Service Manual Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM 350FAVE VAM 500FAVE VAM 650FAVE VAM 800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationMRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY
MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationtechnical data air conditioning systems FVXS-FV1B R-410A Split Sky Air
technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features.............................................................
More informationHeat Recovery Air Handling Units
Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient
More informationLG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)
Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L
More informationFLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More informationDUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationInstallation Instructions / User s Manual NAXA00101DB Communicating Daughter Board
Installation Instructions / User s Manual NAXA00101DB ommunicating Daughter Board The NAXA00101DB daughter board control allows for using 4 existing thermostat wires in an existing, finished home to communicate
More informationSERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1
SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationConcealed ceiling unit with medium ESP
FXSQ-A Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market Slimmest unit in class, only 245mm (3mm built-in height) and therefore narrow ceiling
More informationFLOOR CONSOLE / UNDER CEILING DUAL type
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT
More informationtechnical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air
technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationSEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationTECHNICAL & SERVICE MANUAL. Ceiling Concealed
STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationSERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2
Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationTECHNICAL & SERVICE MANUAL
AIR CONDITIONERS 0 TECHNICAL & SERVICE MANUAL Models P0VMA(L)-E, P5VMA(L)-E, PVMA(L)-E, P40VMA(L)-E, P50VMA(L)-E, P6VMA(L)-E P7VMA(L)-E P80VMA(L)-E P00VMA(L)-E P5VMA(L)-E P40VMA(L)-E Safety Precautions
More informationtechnical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air
technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT
More informationSERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B
More informationMHW Air Handling Unit (50/60Hz)
Technical Manual MHW Air Handling Unit (50/60Hz) MHW015A MHW025A MHW035A MHW050A MHW020A MHW030A MHW040A Engineered for flexibility and performance. TM MHW - 2011 (50Hz/60Hz) Contents Literature No.: TM-MHW-1101A
More informationTECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3
More informationMUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service
More informationGREEN REFRIGERANT R-410A
PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.
More informationPackaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N
Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification
More informationCondensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...
condensing units MDH / DH, MDF / DF series ondensing units ondensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units... intarbox entrifugal condensing
More informationEnergy. The Energy ducted units have been designed. Heat Recovery Unit
Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More informationtechnical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air
technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................
More informationTECHNICAL & SERVICE MANUAL
RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. OC0 TECHNICAL & SERVICE MANUAL Series SLZ Ceiling Cassettes R0A Indoor unit [Model names] SLZ-A09AR SLZ-AAR SLZ-A8AR [Service Ref.] SLZ-A09AR.TH SLZ-AAR.TH
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationRECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install
REUPER DRY ontrolled mechanical ventilation with dehumidification and air treatment GB 0 ir conditioning Ideas to install Recover... your wellbeing The home is a precious asset where we all spend a major
More informationSiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU
SiUS39-601 RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU R-410A Heat Pump 60Hz 1. Introduction... vi 1.1 Safety Cautions...vi 1.2 PREFACE...
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationTECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.
More informationVRV IV i-series heat pump
VRV IV i-series heat pump for indoor installation unique patented concept Air curtain Biddle Air curtain for VRV (CYV) 22 Indoor units VRV type indoor units Control systems Ventilation Heat Reclaim ventilation
More information50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control
PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original
More information11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type
11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,
More informationCEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationSERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A
OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More informationEngineering Data Book
40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationCeiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)
Technical Manual Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz) Models: MCW1400 MCW1600 Air Flow: 2270-3020m3/h MCW1800 Engineered for flexibility and performance. TM MCW-C/F(High
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationSeries PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L)
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2018 SERVICE MANUAL Series PEAD R32/R4A Models PEAD-SM71JA(L) PEAD-SM0JA(L) PEAD-SM125JA(L) PEAD-SM1JA(L) NOTE: This manual describes only service data
More informationRVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.
ENERGY RECOVERY VENTILATORS MODEL RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO and saves energy. Indoor air quality inside a building is optimised through Lossnay is a total
More informationset 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)
1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto
More information