SLC Receiver. SLC Transmitter
|
|
- Alicia Holt
- 6 years ago
- Views:
Transcription
1 SLC Receiver READY TEST INPUT 5 OSSD MPCE OSSD2 MPCE 2 SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector
2 Typical SLC Wiring to MPCEs using Relay Monitor Option (/29) SLC Receiver w/ Relay Monitor Option (/29) READY MPCE MPCE2 RELAY MONITOR OSSD OSSD2 MPCE* MPCE2* SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector * To meet Control Reliability and Category requirements, MPCE and MPCE2 should be positively-driven (forceguided) contact devices. (MPCE = Machine Primary Control Element.) MPCE monitoring can be accomplished by wiring normally-closed contacts from each device in series into the Relay Monitor input of the light curtain.
3 Typical SLC Wiring to SR SLC Monito Safety Relay (SLC Relay Monitor Option not requi) SLC Receiver READY TEST INPUT OSSD OSSD2 SR SLC S2 S A2 A SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector * The SR SLC is a self-monito safety relay module, thus SLC Receiver relay monitoring (Option /29 ) is not necessary to meet Category. The SR SLC has internally undant and monito circuitry -- should a fault occur within its logic or safety outputs (including a welded contact), it will fail to safety (outputs OPEN) and prevent subsequent operation until the failure is corrected.
4 Typical SLC Wiring to SR SLC Monito Safety Relay (using SLC with Relay Monitor Option /29) SLC Receiver SLC Transmitter READY OSSD OSSD2 RELAY MONITOR SR SLC S2 S A2 A 2 2 Module must be configu for auto restart via jumper between terminals & 5 Note: Numbers shown refer to pin # s on M2 connector The SR SLC is a self-monito safety relay module, thus SLC Receiver relay monitoring (Option /29 ) is not necessary to meet Category. The SR SLC has internally undant and monito circuitry -- should a fault occur within its logic or safety outputs (including a welded contact), it will fail to safety (outputs OPEN) and prevent subsequent operation until the failure is corrected. If SLC light curtains WITH Option /29 are being used, the RELAY MONITOR input (Pin ) on the SLC Receiver must be connected to the NC status outputs from the SR SLC module as shown above. Module must also be configu for auto restart via jumper between terminals and 5.
5 SLCS/SLCT is configu for Auto Restart Relay Monitor Disabled Beam Code A # is a floating (n.c.) terminal inside the ASi node it is used here as a convenient spot to tie these three leads together Wiring into the VA-2E-G-SE Safety Node: SLCS/SLCT is configu for Auto Restart Relay Monitor Disabled Beam Code A Wiring into the Terminal Strip on the ASi Demo Case: To SLCS/SLCT Receiver To SLCS/SLCT Transmitter
6 SLCS and SLCT Optional Feature Selection Wiring Examples: Transmitter Mode A: TEST Transmitter Mode B: TEST
7 SLCS and SLCT Optional Feature Selection Wiring Examples: Receiver, Auto Restart, RM Enabled, Mode A: K K2 Status Lamp (Optional) K K2 Receiver, RI Enabled, RM Enabled, Mode B: K K2 Status Lamp (Optional) K K2
8 SLCS and SLCT Optional Feature Selection Wiring Examples: Receiver, Auto Restart, RM Disabled, Mode A: Status Lamp (Optional) K K2 Receiver, RI Enabled, RM Disabled, Mode B: Status Lamp (Optional) K K2
Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS
Safety Control Modules for Emergency Stop Circuits TYPICAL APPLICATIONS APPROVALS DIMENSIONS Single Channel Emergency Stop Module E-Stop circuits up to Category 2 (EN 954-) Sliding door protection Conveyors
More informationHands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018
Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via
More informationGuardShield PAC Type 4 (Perimeter Access Control) Safety Light Curtain User Manual
GuardShield PAC Type 4 (Perimeter Access Control) Safety Light Curtain User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE
More informationSmall Light Curtain. Industry s smallest Type 4 light curtain for safeguard SERIES
Type 4 Small Light Curtain SERIES Industry s smallest Type 4 light curtain for safeguard Compliant with international safety standards The highest standards of safety have now been achieved Reduced requirements
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationF3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series
Safety Light Curtains F3SJ Overview Introducing the F3SJ Series NEW! Three Versions available to meet your exact safety needs All versions conform to the latest Type 4, PLe and SIL3 requirements. F3SJ-E:
More informationACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.
ACTIV8 ONE OFF USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR 1 Description Cover 2 nd Radar Antenna Radar motion sensor Push-Buttons IR-Presence sensor Radar Antenna clip IR-Prism
More informationv Model No: TIMER Multi-function Timer Module Please note: * eeee on the display indicates a non valid dip-switch setting.
Multi-function Timer Module Model No: TIMER Specifications: Power input range...10v ~ 14V DC Functions...1sec to 59minute timer output...1minute to 24hours timer output...auto door closure...guard awake
More informationUC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:
UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK 40 Dale Street West Babylon, NY 11704 Ph: 631-753-9550 Fx: 631-753-9560 www.unionconnector.com Emergency Automatic Transfer System STANDARD SPECIFICATIONS
More informationINSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA
More informationFF-SYB14, FF-SYB30 and FF-SYB50 Series Safety Light Curtains. FF-SYB234 Multibeam Systems for Access Detection
FF-SYB14, FF-SYB0 and FF-SYB50 Series Safety Light Curtains FF-SYB24 Multibeam Systems for Access Detection 200-2004 Honeywell International Inc. All rights reserved IMPROPER INSTALLATION Consult with
More informationSTATUS ALARM HISTORY ALARM RESET
Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN
More informationINSTALLATION INSTRUCTIONS
TT-46 8/05 INSTALLATION INSTRUCTIONS Original Issue Date: 8/05 Model: Automatic Transfer Switches equipped with MPAC 500 Controls Market: ATS Subject: External Alarm Module (EAM) Kit GM38795-KP Introduction
More informationOriginal operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...12 m OY UK 704555 / 05 02 / 2018 Contents 1 Preliminary note...4
More informationPioneer-R16 Gas Monitor Operator s Manual
Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.
Technical Information Electric Slide-In Range JES8850BC* JES9900BC* JES9860BC* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair
More informationDescription. Optex Incorporated
Optex Incorporated Description 1845 W. 205 th St. Torrance, CA 90501-1510 USA TEL (310) 533-1500 and (800) 966-7839 FAX (310) 533-5910 Doc: Model: Desc: Architect/ Engineer Specifications CX-502 PIR Intrusion
More informationWater Leak Detector. Installation and Troubleshooting. Overview
Overview Water Leak Detector The Water Leak Detector is designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. Upon water detection, an
More informationMSI Safety relays. MSI-T functions
MSI Safety relays Photoel. sensors/ light scanners, cubic housing MSI-T functions 1 Start/restart interlock selectable 2 Contactor monitoring (EDM) selectable 3 "Error" message output Photoel. sensors/
More informationMODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL
5CIM2-0413 W30-AC0056 MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL Multi-zone Hydronic Chiller Interface Module SECTION 1: INTRODUCTION Unit description... 5 Location... 5 Handling... 5
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions
HZM-Series-Class I, Div 2 Battery Unit HZM-Series-Class I, Div 2 Battery Unit Instalation instructions IMPORTANT SAFEGUARDS 1 4 5 6 7 13 When using electrical equipment, basic safety precautions should
More informationtcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual
tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual This manual covers operation of the tcm100 and tcm101 Series Temperature Control Modules.
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationRefrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA
Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND
More informationKey-Operated Switch GMA 41 / GMA 44 SW. Operation Manual
Key-Operated witch GMA 41 / GMA 44 W Operation Manual Table of contents Page Introduction... 4 Key function... 4 Distinction of GMA 41/44 W models... 4 Relays... 5 P.C. boards of GMA 41/44 W... 7 Terminal
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.
Technical Information Electric Slide-In Range JES9750BA* JES9860BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
More informationSLC 220 E/R RFBS
26.10.2016 09:10:02h Datasheet SLC 220 E/R0325 30 RFBS Safety light curtains, Safety light grids / Safety light curtains / SLC 220 Protection class IP65 Safety type 2 in accordance with IEC 61496 1 Resolution
More informationFSLIMPRO
1. INTRODUCTI FSLIMPRO is especially designed and built for quick and easy installation. Installation is truly made easy and wiring up is minimised (only the power supply cable and alarm contacts require
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit
Emergency Light Unit IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not
More informationAFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION
968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3
More informationPump Logic User Manual CB-1000 P/N ILK-CB1000-1
Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made
More informationPHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationFLAME AMPLIFIER MODULE 3001
SYSTEM 3000 / 4000 FLAME AMPLIFIER MODULE 3001 TECHNICAL DESCRIPTION EDITION TB_3001_EN_REV03 BFI Automation Mindermann GmbH, Eggerscheidter Str. 57, D-40883 Ratingen Phone +49 (0) 2102 96 82 0, Fax +49
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions
3LERHZ Series Class I, Div 2 Combo Unit Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit IMPORTANT SAFEGUARDS 1 3 When using electrical equipment, basic safety precautions should always
More informationMODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES
MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION EIGHT RED LEDS INDICATE ZONE STATUS SELECTABLE NORMALLY-OPEN,
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Technical Information Electric Slide-In Range JES8850ACB/S/W JES9750ACB/W JES9800ACB/S/W JES9860ACB/S/W Due to possibility of personal injury or property damage, always contact an authorized technician
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationMBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.
24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationMASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page
More informationBE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.
INSTALLATION INSTRUCTIONS FOR SYMCOM S CONTROL MODEL PC-05 BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.!
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationAquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS
AquiTron Liquid Detection Module INSTALLATION INSTRUCTIONS Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions
More informationearth safe Fuel Systems for Critical Power
BACnet, Modbus, Metasys N2, or LON Communications General Description Safe Fuel Storage Inside Buildings. Earthsafe day tanks safely store fuel for generarator engine consumption within the building. Day
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationSAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.
SAFEMASTER PRO The configurable safety system versatile and extendable Our experience. Your safety. The modular safety system: Safe flexibility SAFEMASTER PRO: also as a stand-alone solution You may know
More informationOperating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA
Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4
More informationINSTRUCTION MANUAL. Handy Controller Exclusive for SF4B / SF4B<V2> Series. SFB-HC Ver.2.1 FUNCTION CANCEL ENTER
INSTRUCTION MANUAL Handy Controller Exclusive for SF4B / SF4B Series SFB-HC Ver.2.1 FUNCTION - + CANCEL ENTER Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SFBHC No.0037-78V (MEMO) 1 Panasonic
More informationALARM OUTPUT MODULE. Product #7736
ALARM OUTPUT MODULE The Alarm Output Module (AOM) enables you to use weather station alarms or commands from your computer to automatically start or stop external devices such as indicator lights, audio
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationMODEL B2 INSTALLATION MANUAL
RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.
Technical Information Electric Downdraft Slide-In Range JES9800BA* JES9900BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of
More information/ / 2018
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) with IP69K protective tube Protected area width (range) 0...10 m OY4xxS UK 704859 / 05 02 / 2018
More informationProduct Manual. The `Safety Shoe (shown below):
SAFETY SHOE PBB AUTO-LEVELER BACKUP & AIRCRAFT DOOR PROTECTION PRODUCT MANUAL The `Safety Shoe (shown below): Protects the Aircraft Door as Auto-Leveler backup in normal passenger loading and unloading
More informationSPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System
SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following
More informationOperating Manual MS220KA and MSR220KA
Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße
More informationSMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL
Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions
More informationHE-B Series Commissioning Report & User Guide
Small Duct High Velocity Heating, Cooling and Home Comfort Systems HE-B Series Commissioning Report & User Guide Manufactured By www.hi-velocity.com Module-HEB-COM-Commissioning-Report-and-User-Guide-061616
More informationRMS/RPX Reader. User Manual
RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,
More informationÇ Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX BACKUP PUMP CONTROL SYSTEM MODEL NUMBER BPC-3 November 22, 1999 Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA Telephone:
More informationCONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA
CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC
More informationHigh Mount. Low Mount. High security wired tri-technology external detectors with anti-masking
High Mount Low Mount High security wired tri-technology external detectors with anti-masking XDH10TT-AM Installation height 2.4m High Mount Installation - XDH The XDH detectors optical configuration is
More informationELECTRONIC FLAME SUPERVISION MULTI-BURNER
MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,
More informationNotes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin
Notes: Warrick Series 67 Intrinsically Safe Multi-Function ontrol Installation and Operation Bulletin Form 670 Sheet P/N 100501-1 Rev. F Table of ontents Page 3 Page Page 5 Page 6 Page 7 Page 8 Page 9
More informationMR-2602 Two Zone Fire Alarm Control Panel
MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...
More informationSeries DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions
Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions Bulletin E-97DC Thank you for purchasing the Dwyer DCT1000DC Dust Collector Timer Controller. You
More informationD-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit
D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationT8411R Electronic Heat Pump Thermostat
T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from
More informationREMOTE CONTROL CAR ALARM SYSTEM
REMOTE CONTROL CAR ALARM SYSTEM Email: technicalsupport@stadiumcp.co.uk SPARKRITE SR90 REMOTE CAR ALARM SYSTEM INTRODUCTION The Sparkrite SR90 advanced remote control alarm system incorporates the latest
More informationOccupancy Sensor LS Descriptions. Product Profile. Technical Specifications
LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and
More informationFF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features
C US FF-ST Series Type Safety Light Curtains Approved as Type per IEC/EN 19-1/ Description The FF-ST Series is designed for hazardous point-of-operation or access detection in industrial machine safeguarding
More informationSafety Light Curtains Area Access Control
Presence Sensing Safety Devices Description The AAC photoelectric safety switch is a single-beam, noncontact presence sensing safety device consisting of separate transmitter and receiver units. The light
More informationKIT IOM
8733 800-259 KIT IOM Replacement Kit: 641-176 641-187 641-225 641-244 1 Table of Contents THE UPM CONTROLLER...3 SPECIFICATIONS...4 KIT INCLUDES...5 INSTALLATION PROCEDURE...5 Remove Old Board...5 Mounting
More informationITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual
ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,
More informationSAFETY RELAY APPLICATION
SAFETY RELAY APPLICATION Application manual for YRB-4EML-31S safety relay Designation: Revision: Order No.: SAFETY RELAY APPLICATION 02 / 13.07.2016 605-000-728 This manual is valid for: YRB-4EML-31S from
More informationLa Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual
La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain
More informationNO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting
Features PIR movement detector for internal or external installations - wall mounting Small size Adjustable ambient light intervention threshold Adjustable Light On Time Universal mounting position - permits
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationINSTALLATION MANUAL AND OPERATING INSTRUCTIONS
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD41-1200 SERIES TERRAIN AWARENESS ANNUNCIATION CONTROL UNIT for SANDEL ST3400 TAWS MD41-1248 28vdc Horizontal Mount MD41-1258 28vdc Vertical Mount (shown
More informationINSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3
2402 COMBUSTIBLE GAS CARD 2 CHANNELS 2404 TOXIC GAS CARD 2 CHANNELS 2407 OXYGEN GAS CARD 2 CHANNELS INSTRUCTION MANUAL Software Revision Card 3.2 DOCUMENT SES-KS-2402-04-07-E REV. 3 2402 2404 2407-2 CHANNELS
More informationModel 4001 Series Single Channel Controller
Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:
More informationSafety Function: Single-beam Area Access Control (AAC)
Application Technique Safety Function: Single-beam Area Access Control (AAC) Products: Guardmaster Dual-input Safety Relay, Single-beam Area Access Control Sensors with E-stop Safety Rating: CAT. 4, PLe
More informationThe CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)
The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationInstruction Manual Model L2 RF Switch
Instruction Manual Model 1582-22L2 RF Switch November 2015, Rev. A CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationTHE EVOLUTION OF CONTROL APP & CLOUD PORTAL
THE EVOLUTION OF CONTROL APP & CLOUD PORTAL APP MAIN APP FUNCTIONS EMERGENCY Facilitates the work of installers and company maintenance operators. Allows control of the functions of all lights of the system.
More informationInstruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules
Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.
More informationNetworkable Fan Coil Controller Specification and Installation Instructions
Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL
More informationFill Point, Level Gauges, and Control Range
Fill Point, Level Gauges, and Control Range Page 1 Contents Fill Points, Level Gauges, and Control Equipment... 3 Fill Point Cabinets... 4 Single Tank Cabinet... 5 Twin Tank Cabinet... 6 Three Tank Cabinet...
More informationGS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL
GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in
More informationLINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry