Product Catalogue Edition 2007

Size: px
Start display at page:

Download "Product Catalogue Edition 2007"

Transcription

1 Product Catalogue Edition 2007 { Creating the perfect environment

2 About Thermo Air A drilling platform owner requires cooling for his processes without the danger of explosion. A store owner would like his customers to be able to shop in a pleasant atmosphere. A film production company requires mobile air treatment units for filming on location. An auto repair company doesn t want dust particles in their spraying cabinet. A home owner requires reliable central air heating for his home. Creative Solutions If the requirement is a mobile solution, has extreme dimensions, is of a peculiar format, has strict criteria or needs the quickest production time within the industrial, commercial, offshore, housing & public utility construction and hire branches, Thermo Air is the answer for unique and creative solutions. Thermo Air creates innovative air treatment products for use in a thousand and one areas. 60 Years of Experience Since it s establishment in 1947, the original organisation has grown to become a large concern containing many companies. The core of Thermo Air consists of specialists with sixty years experience in the air treatment industry. Heating, ventilation, cooling and heat recovery systems are the specialities of our company. All our experience and expertise is used daily to ensure that air is fit to breathe, production processes can be realized to create secure situations and a comfortable living environment. Thermo Air produces numerous solutions and for many years, has provided solutions that no other company has even contemplated.

3 Contents CONTENTS About Thermo Air 2 Home Supply Unit (HSU) 4 High Efficiency Heat Recovery Unit HR-WTW 5 Heat Circulation Unit (ES-2) 8 Ceiling Void Air Heaters (PC-600) 9 Terminal Boxes (DK), Roof Exhaust Units (TVC), Roof Supply Units (DTU) 11 Air Curtain (LG) 15 Unit Heater (UH) 17 Indirect Fired Air Heaters oil/gas (UHR) 19 Fan Box (VK) 22 Heat Recovery Unit (HR-WTW) 27 Compact Air Treatment Units CLK - FA, LBU, FC 30 Direct Driven Centrifugal Fans (DD / DS) 37 High Efficiency Direct Driven Centrifugal Fans (DDEC) 40 Direct Driven Centrifugal Fans (motor outside air stream) (DDE(B) / EM) 42 Direct Driven Tube Axial Flow Fans (TAX) 46 V-belt Driven Centrifugal Fans (HE) 47 Air Handling Unit Concept 51 Mobile Air Treatment Units 56 Electric Motors (EM) 57 Heat and Cooling Coils 58 Components 61 3

4 CENTRAL AIR HEATING, RESIDENTIAL HOME SUPPLY UNIT (HSU) Compact design Energy saving and high efficiency Standard dimensions Low maintenance Description The Home Supply Unit (HSU) is an indirect air treatment system. Heat released by, for example, a central heating system, district heating system or heat pump, is transferred to the air supply through an intermediate medium (water) in heat coils. The main advantages of an indirect system are comfort and low energy costs. The HSU is easy to apply in combination with under floor heating and solar heating along with radiators (to be installed later). This allows you flexibility in your choices, which is not the case with direct (gas) heating systems! Additionally, the self-regulating directcurrent fans only use half the energy used by traditional fans. Function The Home Supply Unit allows you the possibility to heat your home efficiently and comfortably with air treatment. By applying high efficiency heat coils, air filters, energy saving fans with the possibility of heat recovery, you choose the optimal comfort for your indoor climate. In combination with the Heat Recovery Unit (HR- WTW) you can easily supply clean air whilst discharging impure air. This allows an ultimate ventilation balance and a clean & healthy indoor climate as well as ensuring a direct reduction of your energy costs. With only one initial investment, the Home Supply Unit definitely offers you triple advantage of heating, ventilation and cooling your home. Technical specifications The HSU is constructed from durable, corrosion-proof and low maintenance coated materials and is grey in colour - RAL 7035/7036. The high quality, polished interior is thermally and acoustically insulated. This material is self-extinguishing and complies with Fire Classification B1, DIN4102. The HSU has a built in vibration free and noise reduction fan, which can be adjusted to different speeds. Supplied with: innovative intelligent regulators energy-saving direct-current fan (optional) heat coils with copper tubing and profiled aluminium grille applicable in combination with HR-WTW balanced ventilation >90% efficiency (optional) filtering for air purification applicable for low temperature heating cooling battery (optional) automatic moisture meter, remote control (optional) setup socket (optional) Models HSU (ST) standard HSU (EC) economic Heat Recovery Option: HR-WTW Every Home Supply Unit is easily supplemented with a heat recovery module. This module has the same design as the HSU and can be mounted on top. Both appliances become one design. The biggest advantage of the HR-WTW is optimal comfort with a high efficiency of >90%. The Home Supply Unit is available in 6 standard models of various versions, such as the Low Temperature version and the Up-flow or Downflow version. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Thermo Air - Product Catalogue Edition

5 HIGH EFFICIENCY HEAT RECOVERY HR- WTW Thermal efficiency >90% Energy saving of up to 400 m³ gas per year possible Balanced ventilation and air purifying Comfortable energy saving low maintenance Description The High Efficiency Heat Recovery Unit is specifically designed for well balanced ventilation with heat recovery and is perfectly suited for use in combination with the Home Supply Unit. Optimal balanced ventilation is created with this combination, which ensures a healthy and clean indoor climate with minimal energy loss. Function Insulation in buildings and homes has improved which now creates a necessity for improved ventilation and air quality management. Of course a good insulated home consumes less energy but also causes less possibilities for ventilation. Standaard Supplied with: cross flow heat exchanger for heat recovery and condensation discharge balanced ventilation filtering for purification of fresh air supply noise reduction, cross current ventilator with suspended blades balanced air dampers for recirculation By installing heat absorbing glass, modern insulation materials and following modern building techniques, houses are constructed in accordance with the strict Energy Performance Standard (EPN). Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC. Due to these restrictions, humidity levels, dust particles and CO 2 emissions will rise higher than the accepted values. It is now become a necessity for constant ventilation in housing following the balanced ventilation principle. This principle implies that extracted and supplied air should be controlled, as specified in NEN The HR-WTW utilizes the heat emitted from the impure, extracted air to warm the clean external air supply. Both airflows remain strictly separated by a cross current converter. This converter transfers 90% of the warmth which makes the reheating of ventilated air no longer necessary. Energy savings of approximately 400 m³ gas per year is possible. In addition, the fresh air is filtered (filter class G3) to ensure only clean air is supplied. Technical specifications The HR-WTW is constructed from durable, corrosion-proof and low maintenance coated materials and is grey in colour - RAL 7035/7036. The high quality, polished interior is thermally and acoustically insulated. This material is self-extinguishing and complies with Fire Classification B1, DIN4102. The HR-WTW contains our own energy saving and noise reduction IMOFA fan Thermo Air - Product Catalogue Edition

6 HOME SUPPLY UNIT (HSU) / HR-WTW Technical data Home Supply Unit EC HSU (EC) Unit HSU-8(EC) HSU-12(EC) HSU-18(EC) HSU-24(EC) HSU-28(EC) HSU-32(EC) Heating capacity 1) kw 8,0 12,0 18,0 24,0 28,0 32,0 Low Temperature Heating kw 7,0 9,0 14,5 17,0 20,0 24,0 (LTV) 2) Heat exchanger type 9/3S 9/3S 10/4 10/4 10/4 10/4 Air volume m³/h Ventilator type DDEC 9-7 DDEC 9-7 DDEC 9-7 DDEC 9-7 DDEC 9-9 DDEC Filter class G3 G3 G3 G3 G3 G3 External Resistance (maximum) Pa Weight kg Motor rating W Maximum current A 2,4 2,4 2,4 2,4 3,7 6,4 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Dimensions (hxwxd) mm 940x570x x570x x570x x570x x570x x570x600 Article number HSU (EC) HSU (EC-LTV) Home Supply Unit ST HSU (ST) Unit HSU-8 (ST) HSU-12 (ST) HSU-18 (ST) HSU-24 (ST) HSU-32 (ST) Heating capacity 1) kw 8,0 12,0 18,0 24,0 32,0 Heat exchanger type 9/3S 9/3S 10/4 10/4 10/4 Air volume m³/h Ventilator type DD /3 DD DD DD DD Filter class G3 G3 G3 G3 G3 External Resistance Pa (maximum) Weight kg Motor rating W Maximum current A 1,00 1,50 2,50 3,40 3,80 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Dimensions (hxwxd) mm 940x570x x570x x570x x570x x570x600 Article number HSU (ST) ) LPHW flow/return conditions ºC (other conversions available on request) 2) Warm water conversion 55-45ºC (type EC / LTV) HR-WTW (heat recovery) HR-WTW Unit WTW-8 (EC) WTW-12 (EC) WTW-18 (EC) WTW-24 (EC) WTW-28 (EC) WTW-32 (EC) Air volume m³/h 75 / 125 / / 125 / / 125 / / 125 / / 125 / / 125 / 225 (low / medium / high) Ventilator type type DDEC DDEC DDEC DDEC DDEC DDEC Filter Class class G3 G3 G3 G3 G3 G3 Cross current converter type WTB-HR-7 WTB-HR-7 WTB-HR-7 WTB-HR-7 WTB-HR-7 WTB-HR-7 Weight kg Motor capacity W Maximum engine flow A 2,00 2,00 2,00 2,00 2,00 2,00 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Dimensions (hxwxd) mm 640x570x x570x x570x x570x x570x x570x430 Article number 1) WTW (EC) ) The Standard WTW 8-12 is a standard stocked article, WTW and available on request Thermo Air - Product Catalogue Edition

7 HOME SUPPLY UNIT (HSU) / HR-WTW Product Options Options Type Article number Setup socket (height 250 mm) HSO HSO Measurements 1. Fresh Air Supply 2. Impure Air Extraction 3. Return-Air from bathroom etc. 4. Circulated Air Water side connections HSU 8 and 12 -> 22mm diameter HSU 18, 24, 28, 32 -> 1 diameter Position 1-4 can be adapted Dimensions Letter HSU-8 HSU-12 HSU-18 HSU-24 HSU-28 HSU-32 H B D H Thermo Air - Product Catalogue Edition

8 AIR HEATING > AIR CIRCULATION UNIT / DESTRATIFICATION ES-2 Saving on energy costs Functions independently Applicable in combination with (in)direct fired air heaters Simple and efficient Description The ES-2 reduces energy costs in a very effective way and is particularly effective in high spaces. Transmission loss results in escaped energy, for example, through the roof. The ES-2 forces the rising, heated air back down. This results in a smaller area in which heat is suspended like a warm blanket. The ES-2 provides a direct contribution to the energy savings in a very efficient way. Function By lowering the rising, heated air you directly save energy by needing less heat. The fitted thermostat operates the unit when the set temperature has been reached. The unit only functions, therefore, when the effective temperature is reached at high level. In addition to saving energy this system of operation ensures the unit does not run unnecessarily and reduces humidity. Air is distributed effectively by way of an adjustable double deflection outlet grille. For optimum performance the ES-2 unit should be mounted at a maximum height of 8 metres. Technical specifications The ES-2 is constructed from durable, corrosion-proof and low maintenance coated panels and is grey colour - RAL 7035; other colours on request. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC. Supplied with: adjustable double deflection outlet/grille axial fan thermostat four suspension hooks for roof/ceiling installation Technical data Heat Circulation Unit ES-2 Air volume m³/h 2000 Sound 1) db(a) 55 Weight kg 15 Installed engine power W 140 Maximum A 0,65 Nominal power Revolutions n ,00 Electrical connection V/ph/Hz 230/1/50 Dimensions (lxwxh) mm 460x460x340 Article number ES ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values +/- 3 db(a) Product Options Options Type Article number Cut out switch WS Measurements 4 suspension hooks All measurements in mm Thermo Air - Product Catalogue Edition

9 AIR HEATING > FAN COIL UNIT FOR HEATING CEILING VOID AIR HEATERS (PC-600) Fan coil unit for ceiling installation Heating Available with a complete air distribution kit Compact design Description The PC-600 is a fan coil unit suitable for installation in ceiling voids. Due to the low noise level this system is frequently applied in areas where heating, recirculation and ventilation is required. The PC-600 has pre-coated plating which enables direct installation in any area. The minimum height of the PC-600 Unit is 285mm which ensures easy installation in ceiling voids. There are three circular connections situated on the outlet side, which can be easily connected to an air duct system. These units are normally applied for heating. The PC-600 is available with a air distribution system, complete with flexible hose, plenums return and distribution grilles. Supplied with: filter (optional) high efficiency heat coils for warmth twin centrifugal fans three circular connections, suitable for ø200mm connections complete air distribution kit (optional) room thermostat and 3 step switch (optional) Function With a heating capacity of 15 kw, the PC-600 is a powerful unit. Air is supplied by twin low noise centrifugal fans. The PC-600 suctions air from behind the unit. The outlet side consists of three circular connections for easy connection to an air duct system or flexible hoses of ø200 mm. A filter can also be installed on the air supply side. Warm water must be supplied from an external source, such as a boiler, distribution network or heat pump. The PC-600 is optimally used in combination with an Air Curtain LG. Technical specifications The PC-600 is constructed from durable, corrosion-proof and low maintenance coated panels in a light grey colour (RAL 7035). The high quality, polished interior is thermally and acoustically insulated. The PC unit has built in, vibration free and noise reduction fans, which can be adjusted to different speeds. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Standard air distribution-kit, consists of: 3x supply air diffusers 3x air distribution plenums 1x flexible aluminium (non-insulated) hoses with a length of 10 metres 6x hose clamps Thermo Air - Product Catalogue Edition

10 CEILING VOID AIR HEATERS (PC-600) Technical data PC-600 Unit PC-600 Ventilator type DPA /70 Heating capacity 1) kw 15 Air volume m³/h 1080 External resistance Pa 55 Water pressure drop kpa 24 Sound 2) db(a) 40 Weight kg 32 Motor rating W 70 Maximum current A 0,85 Electrical connection V/ph/Hz 230/1/50 Dimension (lxwxh) mm 465x1020x285 Article number PC ) LPHW flow/return conditions ºC (other conversions available on request) 2) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values +/- 3 db(a) Product Options Opties Type Article number Air Distribution Set (3x grille, 3x UKV plenum, 10 metre flexible hose) Filter set Class G3 F Air return grille RR Room thermostat with 3-step switch RT Measurements Front view 1. Warm water entry 2. Warm water exit Back view Water connection 22mm diameter All dimensions in mm Thermo Air - Product Catalogue Edition

11 VENTILATION TECHNIQUE > TERMINAL BOXES WITH OR WITHOUT FAN TERMINAL BOXES (DK), ROOF EXHAUST UNITS (TVC), ROOF SUPPLY UNITS (DTU) Terminal Boxes with or without fan Air supply or air extraction Supplied complete with a Roof Frame and Silencer Durable maintenance free casing Description Balanced air management in buildings begins to play a more important role. The horizontally directed Terminal Boxes of the DTU/ TVC series, have been specifically designed to supply fresh air whilst extracting impure air. These units can be supplied with a Roof Frame. Thanks to intelligent designing, the Silencer can be fitted within the Frame to allow the Terminal to be mounted on top. The Terminal, the Frame and the eventual Silencer can be removed easily and quickly. The Silencer ensures a low noise level in the outside area and in the air duct system. Function Our Terminal Boxes can be supplied with or without fan motors. You are free in your choice of which system suits your requirements. These units are designed for roof installation. The Roof Frame should be installed before roofing material is placed to prevent leakage. Supplied with: maintenance friendly polyester double-walled casing DD-fans energy saving DDEC-fan (optional) Roof Frame (optional) Silencer (optional) fitted activation switch (optional) Speed Controller (optional) step switch (optional) DK, without fan: for air supply or air extraction, with an external fan (VK) TVC with fan: suitable as an air extraction unit DTU with fan: suitable as an air supply unit All types with motor fans can be supplied with a fixed maintenance switch and/or with a separate 3-step switch or speed controller. This makes it possible to remotely control the ventilation flow. Technical specifications The double-walled polyester casing is supplied in the colour RAL9002. This thermally and acoustically insulated casing is durable, resistant to all weather conditions and therefore has a long life expectancy. The TVC s and DTU s are fitted with high quality Imofa fans. These fans are mounted vibration free to ensure silent operation. The TVC is supplied standard with a,back draught shutter that has been specifically selected for optimal balance between flow, air speed and sound. A protection grille is installed standard on the exhaust end. The power cable can be connected without removal of the fan by way of a maintenance switch or motor safe activation switch. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Thermo Air - Product Catalogue Edition

12 TERMINAL BOXES (DK), ROOF EXHAUST UNITS (TVC), ROOF SUPPLY UNITS (DTU) Technical data Terminal Boxes with fan TVC air extraction unit Unit TVC-7 TVC-9 DTU air supply unit DTU-7 DTU-9 Fan type DD /3 DD DD DD DD DD DD Motor rating W Speed rev. / min Maximum current A 0,65 0,60 1,00 2,00 3,10 2,30 3,10 Noise pressure outlet side 1) db(a) Noise pressure outlet side fan db(a) silencer 2) Minimum air volume m³/h Maximum air volume graph Minimum external resistance Pa Weight Kg Speed controller applicable - yes yes yes yes yes yes yes Electrical connection V/ph/Hz 230/50/1 230/50/1 Article number TVC DTU TVC air extraction unit Unit TVC-10 TVC-12 DTU air supply unit DTU-10 DTU-12 Fan type DD DD DD DD DD DD Motor rating W Speed omw. / min Maximum current A 2,30 2,30 4,00 6,00 6,00 7,00 Noise pressure outlet side 1) db(a) Noise pressure outlet side fan db(a) silencer 2) Minimum air volume m³/h Maximum air volume graph Minimum external resistance Pa Weight Kg Speed controller applicable - yes yes yes no no no Electrical connection V/ph/Hz 230/50/1 230/50/1 Article number TVC DTU ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values +/- 3 db(a) 2) Only for type DTU Models Thermo Air - Product Catalogue Edition

13 TERMINAL BOXES (DK), ROOF EXHAUST UNITS (TVC), ROOF SUPPLY UNITS (DTU) Terminal boxes without fan DK air supply and extraction Unit DK-7 DK-9 Model Air volume m³/h Air speed m³/s 0,28 0,56 0,83 1,11 0,42 0,83 1,25 1,67 Weight Kg Article number DK DK Terminal Unit DK-10 DK-12 Model Air volume m³/h Air speed m³/s 0,56 1,11 1,67 2,22 0,69 1,39 2,08 2,78 Weight Kg Article number DK Models Product Options Options Type DK-7 / TVC-7 / DTU-7 DK-9 / TVC-9 / DTU-9 DD /3 DD DD DD DD DD DD Adapter plate *) T *) Roof frame DO Silencer GD Vertical discharger V Speed controller TRK Electronic speed controller VEB Maintenance switch WS Options Type DK-10 / TVC-10 / DTU-10 DK-12 / TVC-12 / DTU-12 DD DD DD DD DD DD Adapter plate *) T *) Roof frame DO Silencer GD Vertical discharger V Speed controller TRK Electronic speed controller VEB Maintenance switch WS *) Adapter plate T option available for the DK and TVC. Supplied as standard with the DTU. For converting the DK to DTU, and as a connection to the air duct for the DK Thermo Air - Product Catalogue Edition

14 TERMINAL BOXES (DK), ROOF EXHAUST UNITS (TVC), ROOF SUPPLY UNITS (DTU) Fan selection curves (TVC/DTU) Measurements Dimensions Model TVC-7 TVC-9 TVC-10 TVC-12 DTU-7 DTU-9 DTU-10 DTU-12 DK-7 DK-9 DK-10 DK-12 A B D E F G H T / Adapter plate I K L M N GD / Silencer DO / Roof frame Thermo Air - Product Catalogue Edition

15 AIR HEATING AIR CURTAIN (LG) Air heating with high capacity Solid and compact design Easy to maintain Energy saving Description Air curtains are typically applied in store entrances, hospitals and public buildings. By using a barrier of warm air, an air curtain protects building entrances from energy loss, draught, dust and insects. A properly selected and installed air curtain ensures a conditioned climate in your store, showroom or restaurant by preventing your heating or air conditioner from generating energy bursts whenever visitors enter or leave. Custom made solutions are available. Function A good airflow is essential for the perfect distribution of warmth and air in the room. This optimal warmth distribution is attained by the powerful centrifugal fan-motor and adjustable outlet blade. The advised height is 2.5 metres. Warm water to be supplied by an external source, such as a boiler, central distribution network or heat pump. The air curtain is optimally used in combination with the air heater PC-600. Supplied with: filter high capacity heat coil twin centrifugal fan adjustable outlet blade maintenance switch (optional) speed controller (optional) room thermostat (optional) Technical specifications LG Air Curtains are constructed from durable, corrosion-proof and low maintenance coated panels in the colour RAL 9016 (white). All components, including the silent twin centrifugal fans, are securely built in to the thermally and acoustically insulated casing. The fan can be adjusted to different speeds Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Thermo Air - Product Catalogue Edition

16 AIR CURTAIN (LG) Technical data Air curtain Unit LG-1/18 LG-2/36 Heating capacity 1) kw Heat coil type WWFA-800/2 WWLG-2 Water pressure drop kpa 5 8 Fan type /3 FD /3 FD Amount double fans ea 1 2 Filter class G3 G3 Air volume m³/h Sound 2) db(a) Weight kg Max. recommended height m 2,5 2,5 Motor rating W Max. current A 1 2 Electrical connection V/ph/Hz 230/1/50 230/1/50 Dimensions (lxwxh) mm 480x1000x x2000x300 Article number LG ) LPHW flow/return conditions ºC (other conversions available on request) 2) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product Options Options Type LG-1/18 LG-2/36 Flat filter set G3 F Room thermostat RT Maintenance switch WS Measurements Rear view 1.) 2 knock outs of 26mm Front view Diameter waterconnections round 22mm All dimensions in mm Dimensions LG A B LG 1/ LG-2/ Thermo Air - Product Catalogue Edition

17 AIR HEATING > INDIRECT FIRED AIR HEATER UNIT HEATER (UH) Classic air heater Easily expandable Compact air handling Sturdy and durable Description The Unit Heater is a classic Thermo Air product. With it s characteristic design, this product can be found throughout Europe and beyond. Ever since the 60s these indirectly fired air heaters have been installed in storerooms, storage facilities, workshops, etc. These air heaters are sturdy and flexible and were designed to operate reliably over a long lifetime. No situation is ever the same and therefore the Unit Heater can be modified to suit client s diverse needs. All modifications and options are possible. If it s a supply or return plenum, mixing box, room thermostat or speed controllers, these air heaters have numerous possibilities. Even at a later stage, this unit can be easily expanded to become a complete air handling system. By adding a filter, mixing section, cold water heat exchanger and perhaps a Terminal Box, you can easily construct a complete system (CLK-range). Supplied with: high capacity heat exchanger IMOFA DD-alternating current fan dual adjustable outlet grille filter (optional) mixing box with dampers (optional) maintenance switch (optional) speed controller (optional) plenums (optional) room thermostat (optional) Function Air direction and speed are essential for optimum heat distribution. The dual adjustable outlet grille controls air direction. Air speed is attained by adequate static pressure. These conditions cannot be reached with a (noisy) axial fan. That is why a silent but powerful centrifugal fan is used in the Unit Heater. The Unit Heater ensures optimal heat distribution. Depending on the model, air throw of up to 30 metres can be attained. Technical specifications The Unit Heater is constructed from durable, corrosion-proof and low maintenance coated panels in a light grey colour (RAL 7035); other colours are available on request. The components are built in the high quality, polished casing which is thermally and acoustically insulated. The silent, low speed IMOFA DD fan provides the required pressure for a significant airflow and bridges the resistance of an eventual filter, mixing box and/or duct system. Because the maximum capacity is not always required, the fan can be adjusted to different speeds. The Unit Heater is available in 3 standard models and various versions. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Thermo Air - Product Catalogue Edition

18 UNIT HEATER (UH) Technical data Unit Heater Unit UH-7 UH-9 UH-10 Heating capacity 1) kw Heat coil type 7/2 9/2 10/2 Water pressure drop kpa Fan type DD DD DD Air volume m³/h Airflow (max.) m Sound 2) db(a) Weight 3) kg Motor rating W Maximum current A 0,6 2,3 2,3 Eletrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 Dimensions (lxwxh) mm 500x420x x520x x620x620 Article number UH ) LPHW flow/return conditions ºC (other conversions available on request) 2) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) 3) Base unit consisting of heat coil and fan Product Options Options Type UH-7 UH-9 UH-10 Flat filter set F Outlet plenum 4 sided with adjustable grille PL Mixing box with 2 dampers MK Mixing box with 2 dampers and flat filter MKF Room thermostat (230V) RT Speed controller (in plastic casing) TRK Maintenance switch WS Servomotor (230V open/shut) SM on request Measurements Dimensions Letter UH-7 UH-9 UH-10 L B d G d d P M h h b c Thermo Air - Product Catalogue Edition

19 AIR HEATING / SPECIAL PROJECTS > DIRECT FIRED AIR HEATERS DIRECT FIRED WARM AIR HEATER UHR Oil or gas fired Chromium steel combustion chamber Warehousing,Workshops,Showrooms,Factories,Garages,Spraying Cabinets, Drying Tunnels Etc. Standard or customised Description The UHR direct oil and/or gas fired warm air heaters are mainly applied for heating industrial processes. These versatile units are also used for the heating of warehouses,workshops,showrooms,factories garages, poultry housing and the furniture industry. The UHR is used globally in spraying cabinets and drying tunnels for luxury vehicles and yachts. These units can be used in vertical or horizontal positions due to the flexibility of our design. As well as 13 standard models we also supply customised models to comply with your project and demands. Because the UHR is oil and/or gas fired, it can be supplied with or without a high quality burner. Where your own burner is used, we will supply a customised securing plate following your specifications. Every UHR can therefore be used with every type of burner. The chromium steel combustion chambers are supplied by us with a guaranteed long life expectancy. Function The chromium steel combustion chamber is heated by fuel from a burner. The air is heated when the IMOFA circulates the air around the combustion chamber. The air is then distributed through the room by the air distribution system. For a more standard application such as setting up directly in the room, we propose the multi-directional air distribution plenum PL4. Installatie The technical installation of a UHR must be performed by a professional technician, in accordance with the national and regional standards. Always install the UHR in a sufficiently ventilated area. Technical specifications The UHR is constructed from durable, corrosion-proof and low maintenance coated panels in a light grey colour (RAL 7035); other colours are available on request. The components, including the chromium steel chamber and centrifugal fan, are built in a welded frame construction. The panels are thermally and acoustically insulated. Every unit is completely wired and ready for use. The UHR is available in 13 standard models or customised models following customer specifications. Componenten high capacity chromium steel combustion chamber according to Directive 90/396/EEC, CE0063 Certification number E3110 high capacity IMOFA-centrifugal fan fan thermostat and maximum high limit safety cut-out mixing box with dampers (optional) maintenance switch (optional) mounted oil- and/or gas burner (optional) multi directional air distribution plenum (optional) filter section (optional) room thermostat RT-1 (optional) Model Vertical (V) standard Horizontal (H) on request Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC and Directive 90/396/EEC Thermo Air - Product Catalogue Edition

20 DIRECT FIRED WARM AIR HEATER UHR Technical data UHR Model Type Unit UHR-25 UHR-30 UHR-40 UHR-55 UHR-70 UHR-100 Heating capacity 1) Vertical (URH-V) Horizontal (URH-H) Oil kw Gas kw Oil kw Gas kw Fan type DD DD DD DD DD HE-450 Air volume m³/h External resistance 2) Pa Sound 3) db(a) Weight kg Filters class G3 G3 G3 G3 G3 G3 Motor rating kw 0,245 0,245 0,245 0,920 0,920 0,75 Maximum current A 2,3 2,3 2,3 7,0 7,0 2,1 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/ /3/50 Article number UHR-V 4) UHR-H 5) UHR Opstelling Type Unit UHR-130 UHR-150 UHR-185 UHR-250 UHR-300 UHR-350 UHR-450 Heating capacity 1) Vertical (URH-V) Horizontal (URH-H) Oil kw Gas kw Oil kw Gas kw Fan type HE-450 HE-500 HE-500 HE-500 HE-500 HE-630 HE-800 Air volume m³/h External resistance 2) Pa Sound 3) db(a) Weight kg Filters class G3 G3 G3 G3 G3 G3 G3 Motor rating kw 0,75 1,10 1,50 1,50 1,50 3,00 4,00 Maximum current A 2,1 3,0 3,7 3,7 3,7 7,1 8,7 Electrical connection V/ph/Hz /3/ /3/ /3/ /3/ /3/ /3/ /3/50 Article number UHR-V 4) UHR-H 5) ) Nominal capacity (Qnom.) 2) Dependant on the type of fan, other fans available on request 3) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) 4) Vertical standard flue tube at the back 5) Horizontal standard flue tube on the surface Product Options UHR Type UHR-25 UHR-30 UHR-40 UHR-55 UHR-70 UHR-100 UHR-130 Outlet plenum (4 sided) with dual PL adjustable outlet blades 1) Return grille RR Filter frame (flat filter) FK Oil and/or gas burner B Various possiblities available on request UHR Soort UHR-150 UHR-185 UHR-250 UHR-300 UHR-350 UHR-450 Outlet plenum (4 sided) with dual PL adjustable outlet blades 1) Return grille RR Filter frame (flat filter) FK Oil and/or gas burner B Various possiblities available on request 1) Verticle version only Thermo Air - Product Catalogue Edition

21 DIRECT FIRED WARM AIR HEATER UHR Measurements Filtersection Side view Front view PL Plenum Chimney Burnerflange Dimensions UHR-25 UHR-30 UHR-40 UHR-55 UHR-70 UHR-100 UHR-130 UHR-150 UHR-185 UHR-250 UHR-300 UHR-350 UHR-450 L B H H B A A L P M d d Thermo Air - Product Catalogue Edition

22 VENTILATION TECHNIQUE STANDARD VENTILATION UNIT (VK) Air intake and/or air extraction Flexible, adaptable for every (existing) situation Can be combined with terminal boxes, type DK Models suitable for indoor installation Description Balanced air management in buildings is beginning to play a much more important role. That is why ventilation units are used frequently in hotels, restaurants, office buildings and shopping malls. This series is specifically designed to supply fresh air or to extract stale air. Due to their construction, these ventilation units can be easily placed in an indoor environment. The units can be completely made to measure by using the supplied fittings and adapters. This is a stylish and flexible product, which can be adapted to any new or existing situation. The units are produced following three construction types: VK cube model VKS low profile for ceiling void installation VKT with two fans for large air capacity Supplied with: IMOFA DD-fan(s) customised flanges and adapters (optional) fitted maintenance switch (optional) speed controller (optional) step switch (optional) Depending on the construction type and model, these standard units can displace air from 100 to m³/h. Customised ventilation units are available from our LBK-range. Function Our ventilation units are suitable for indoor installation. Because we can supply the units made to measure, they can be fitted to every air duct system. They can be ideally applied in combination with our terminal boxes type DK. One or two fans can be applied, depending on the air volume. Almost all types are equipped with a maintenance switch and/or an internal 3-step switch or speed controller. This makes it possible to remotely control the ventilation flow. Technical specifications Every ventilation unit is constructed of durable galvanised panels. The components, including the silent centrifugal fan(s), are built in a welded steel frame construction. The panels are thermally and acoustically insulated. Also available in a Pentapost style, constructed of aluminium profiles with pre-coated plating in RAL The fan is speed controllable. The ventilation unit is available in three models and various versions Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC Thermo Air - Product Catalogue Edition

23 STANDARD VENTILATION UNIT (VK) Technical data VK cube Ventilation Unit Unit VK-7 VK-9 VK / DD DD Fan type DD-180- DD-7- DD-7- DD-9- DD-9- DD-10- DD-10- DD-11- DD Motor rating W Speed rev. / min Maximum current A 0,65 0,60 1,00 2,00 3,10 2,30 3,10 2,30 2,30 4,00 6,00 Sound 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external resistance Pa Weight Kg Speed controller applicable - yes yes yes yes yes yes yes yes yes yes 2) Electrical connection V/ph/Hz 230/50/1 230/50/1 230/50/1 Article number VK ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product optional extras VK cube Options Type VK-7 VK-9 VK-10 DD /3 DD DD DD DD DD DD DD DD DD DD Speed controller TRK ) Maintenance switch WS ) To be reviewed Flanges and transition pieces from rectangular to circular available on request Thermo Air - Product Catalogue Edition

24 STANDARD VENTILATION UNIT (VK) Technical data VKS low profile Ventilation Unit Unit VKS-7 VKS-9 VKS-10 Fan type DS-7-6 DS-7-4 DS-9-6 DS-9-4 DS-10-6 DS-10-4 DS-11-6 DS-11-4 DS-12-6 Motor rating W Speed rev. / min Maximum current A 0,60 1,00 0,60 1,00 1,20 3,10 2,90 3,70 4,00 Sound 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external Pa resistance Weight Kg Speed controller applicable - yes yes yes yes yes yes yes yes yes Electrical connection V/ph/Hz 230/50/1 230/50/1 230/50/1 Article number VKS ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product optional extras VKS low profile Options Type VKS-7 VKS-9 VKS-10 DS-7-6 DS-7-4 DS-9-6 DS-9-4 DS-10-6 DS-10-4 DS-11-6 DS-11-4 DS-12-6 Speed controller TRK Maintenance switch WS Flanges and transition pieces from rectangular to circular available on request Thermo Air - Product Catalogue Edition

25 STANDARD VENTILATION UNIT (VK) Technical data VKT with two fans Ventilation Unit Unit VKT-7 VKT-9 VKT-10 Fan type DD /3 DD DD DD DD DD DD DD DD DD DD Amount ventilator pieces Motor rating W Speed rev. / min Maximum current A 1,3 1,2 2,0 4,0 6,2 4,6 6,2 4,6 4,6 8,0 12,0 Sound 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external Pa resistance Weight Kg Speed controller applicable - yes yes yes yes yes yes yes yes yes yes 2) Electrical connection V/ph/Hz 230/50/1 230/50/1 230/50/1 Article number VKT ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) 2) To be reviewed Product optional extras VKT with two fans Options Type VKT-7 VKT-9 VKT-10 DD /3 DD DD DD DD DD DD DD DD DD DD Speed TRK ) Maintenance WS ) To be reviewed Flanges and transition pieces from rectangular to circular available on request Thermo Air - Product Catalogue Edition

26 STANDARD VENTILATION UNIT (VK) Measurements VS Adaptor square to round Dimensions Letter VK-7 VK-9 VK-10 VKS-7 VKS-9 VKS-10 VKT-7 VKT-9 VKT-10 L B H B H D Thermo Air - Product Catalogue Edition

27 AIR HANDLING > HEAT RECOVERY, VENTILATION TECHNIQUE HEAT RECOVERY UNIT HR-WTW Air volume of m³/h Heat recovery with 90% high efficiency rate Reheating not required Balanced ventilation Description The HR-WTW air handling units are applied in utility buildings such as offices, schools, sport halls, stores, etc. Heat recovery from every HR-WTW unit has a very high efficiency rating (minimum 90%) which makes reheating rarely necessary. There are various models of this unit available which are suitable for both indoor and outdoor installation. Every unit is supplied completely socket free and fully wired with maintenance switch. If required, every unit can be supplied with a bypass regulator. This enables you to ventilate with cool fresh air independent of the indoor or outdoor temperature. Models The HR-WTW product line is available for the following air capacities: HR-WTW 1500 ( m³/h) HR-WTW 2500 ( m³/h) HR-WTW 3500 ( m³/h) Models HR-WTW 1500 ( m³/h) HR-WTW 2500 ( m³/h) HR-WTW 3500 ( m³/h) Each type is equipped with energy saving fans, optimized for the area in which it is to function. All units have a maximum external resistance of Pa. You can choose for indoor or outdoor installation. Filters The air intake is fitted with filter class F7 and the air extraction is fitted with filter class G4. The HR-WTW line is equipped with easy to remove filters to simplify maintenance and future inspections. Fans The HR-WTW equipped with double suction, direct driven IMOFA DDEC centrifugal fans a DDEC fan has integrated electronics energy saving, high efficiency, direct driven fans every fan delivers a constant volume statically and dynamically balanced an optimal balance between motor and fan ensures a very low noise level 1 fan for supply and 1 fan for extraction flows as standard Thermo Air - Product Catalogue Edition

28 HEAT RECOVERY UNIT HR-WTW High capacity cross-flow heat exchanger a high capacity, aluminium heat coil following the cross current principle with at least 90% efficiency by nominal air volume. Supply and extraction flows are separated by applying a cross flow heat exchanger. high quality aluminium, corrosion free durable and completely recyclable condensation drainage to coated condensation basin Construction Constructed of high quality, aluminium angled steel plating with standard 25mm insulation. Plating is pre-coated in the colour RAL The main advantage of this Pentapost construction is the highclass appearance. aluminium Pentapost construction pre-coated panels in the colour RAL 7035 fire proof insulation, class B1 with a width of 25 mm excellent thermal and acoustic dampening aluminium base frame equipped with lifting holes a weather protection cover is supplied when chosen for outdoor installation a roof installation frame is available on request Models HR-WTW 1500 ( m³/h) HR-WTW 2500 ( m³/h) HR-WTW 3500 ( m³/h) Regulation Every HR-WTW has the option for our own innovative regulating method, which allows for easy operation. If you choose a by-pass, this is then supplied with full regulation. completely wired and equipped with a maintenance switch electrical connection 230V/1ph/50Hz freeze protected possibility for remote control Accessories a full face by-pass complete regulation Thermo Air - Product Catalogue Edition

29 HEAT RECOVERY UNIT HR-WTW Technical data HR-WTW type HR-WTW 1500 HR-WTW 2500 HR-WTW 3500 Air volume (minimum) m³/h Air volume (maximum) m³/h Efficiency WTW % Air flow temperature C Air intake C AIR INTAKE Filter in the supply flow class F7 F7 F7 Fan (supply) type DDEC-9-7 DDEC DDEC External resistance Pa Required Motor rating W Installed Motor rating W Maximum current A 2,4 6,4 6,4 Maximum fan speed rev. / min AIR EXTRACTION Filter in the extraction flow class G4 G4 G4 Fan (extraction) type DDEC-9-7 DDEC DDEC Extern resistance Pa Required Motor rating W Installed Motor rating W Maximum current A 2,4 6,4 6,4 Maximum fan speed rev. / min Weight (indoor) kg Weight (outdoor) kg Indoor (lxwxh) mm 1950x1400x x1400x x1400x1350 Outdoor (lxwxh) mm 1950x1400x x1400x x1400x1390 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 Product data and optional extras HR-WTW FOR INDOOR INSTALLATION HR-WTW 1500 HR-WTW 2500 HR-WTW 3500 Excluding by-pass and excluding regulation Including fitted bypass and complete regulation Extra resistance, 200 Pa external on request - - HR-WTW FOR OUTDOOR INSTALLATION HR-WTW HR-WTW 1500 HR-WTW 2500 HR-WTW 3500 Excluding by-pass and excluding regulation Including fitted bypass and complete regulation Extra resistance, 200 Pa external on request on request - - Fitted roof and weather cover included included included Thermo Air - Product Catalogue Edition

30 AIR HANDLING COMPACT AIR HANDLING CABINETS CLK - FA, LBU, FC Compact and complete Cooling / heating / air intake / air extraction / mixing Standard with (speed regulating) DD-centrifugal fans Durable, sturdy casing Description The air handling cabinet range can be applied in many situations due to its compact design and low construction height. Thanks to their modular construction they are quick and easy to produce and can be adapted if necessary. Every CLK is dependant on the application, air volume and external resistance and can be selected with specific DD/DS IMOFA fans. The eventual process, whether filtering, heating or cooling, will determine which type of CLK is appropriate. We specify three models: the FA, LBU and FC. These units are suitable for air volumes from 400 to 7000 m³/h. Heating, cooling (cold water or direct expansion), mixing or filtering of the air can all be accommadated. A complete CLK is very easy to install thanks to our plug and play concept. Every unit is supplied ready for operation, following your specific instructions.and can include flanges for duct connections, fitted maintenance switches, speed controllers, servomotors etc. This means a considerable saving in the installation time. Typen The CLK-range contains the following models and types: Model Types Air volume (m³/h) FA LBU FC Possibilities: powerful IMOFA DD-fan energy saving DDEC-fan flat filter bag filter heating section cooling section mixing section with opposed blade damper fitted mains/maintenance switch speed controller for the fan Selection table The tables of the CLK show the various possibilities of this flexible product. Because no CLK is identical, prices are only available on request. Please contact our sales team. Function Every CLK uses an IMOFA DD/DS centrifugal fan. This powerful and silent fan is the heart of the unit. Depending on your requirements, there are CLK solutions for: filtering + ventilation filtering + heating filtering + heating + cooling filtering + cooling mixing + filtering + heating + cooling Thanks to the modular construction, this unit can be adapted at a later stage Thermo Air - Product Catalogue Edition

31 CLK - FA, LBU, FC Technical specifications The CLK is constructed of sturdy pre-coated panels in the colour RAL The components, including a heat coil and silent centrifugal fan(s), are built within a welded, aluminium frame construction of the Pentapost category. Complete control/speed regulation is available. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC. Measurements Frontview Discharge Sideview Rearview Suction Options Frontview Discharge for FC-40 / 55 MKF2 Mixing section with filter Option Servomotor MK2 Mixing section FKz-3 Section with bagfilter KRK Damper Dimensions Model CLK-FA CLK-LBU CLK-FC Letter FA-400 FA-600 FA-800 LBU-7 LBU-9 LBU-10 FC-20 FC-30 FC-40 FC-55 L B H B H B H Dimensions Dimensions for opposed blade damper (KRK, optional) type KRK B2 D2 E2 B3 C4 D4 D4 E4 F4 G4 Dimensions Dimensions for mixing section (MK2, optional) b b h h M Thermo Air - Product Catalogue Edition

32 CLK - FA, LBU, FC Technical data CLK - FA CLK FA-400 FA-600 FA-800 FA-800 FA-800 Air volume m³/h Heating and cooling (external resistance) 1) Pa ,5 64,5 53,5 Heating only (external resistance) 1) Pa 84, Cooling only (external resistance) 1) Pa ,5 123,5 134,5 Fan type /3 DS-10-6 DS-10-4 DS-10-4 DDE amount Maximum resistance Pa Filter class G3 G3 G3 G3 G3 amount dimensions 320x x x x x800 Static pressure loss (clean) Pa Static pressure loss 1/2 stale Pa 57, ,5 60,5 60,5 Heating 3) kw 4,7 9, Coil type WWVC200/2 WWFA-600/2 WWFA-800/4 WWFA-800/4 WWFA-800/4 Static pressure loss Pa Water pressure drop Kpa 10 9,5 1,5 1,9 1,9 Cooling 3) kw 6,8 7,9 8,9 Coil type type WWFA-800/4 WWFA-800/4 WWFA-800/4 Static pressure loss Pa Water pressure drop Kpa 2,3 3 3,6 Air speed m³/s 1,8 2,3 2,7 Sound 4) db(a) Motor rating W Maximum current A 0,65 1,2 3,1 3,1 3,1 Electrical connection V/ph/Hz 230//50/1 230/50/1 230/50/1 230/50/1 230/50/1 Length mm Width mm Height mm ) Flat filter, always including static pressure loss of a ½ unclean filter, maximum end resistance 100 Pa 2) Warm water trajectory 80-60, by an air intake temperature of -7C 3) Cold water trajectory 6-12, by an air intake of 28C/60%RV 4) Sound pressure measured at 3 metres distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Thermo Air - Product Catalogue Edition

33 CLK - FA, LBU, FC CLK - LBU CLK LBU-7 LBU-7 LBU-9 LBU-9 LBU-9 LBU-9 LBU-9 LBU-9 LBU-9 LBU-9 LBU-9 LBU-10 LBU-10 LBU-10 LBU-10 LBU-10 LBU-10 LBU-10 LBU-10 Air volume m³/h Heating and cooling (external resistance) 1) Pa 104,5 129,5 85,9 29,5 55,9 285,9 244, ,9 259, Heating only (external resistance) 1) Pa 131,5 156,5 106,9 80,5 76,9 306,9 295, ,9 310, Cooling only (external resistance) 1) Pa 115,5 140, , , , Fan type / amount Maximum static pressure loss Pa Filter class G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 amount dimensions 320x x x x x x x x x x x x x x x x x x x600 Static pressure loss (clean) Pa Static pressure loss 1/2 stale Pa 57,5 57, , , , Heating 3) kw 6 6 9,5 13 9,5 9, , Coil type 7/2 7/2 9/2 9/2 9/2 9/2 9/2 9/2 9/2 9/2 9/2 10/2 10/2 10/2 10/2 10/2 10/2 10/2 10/2 Static pressure loss Pa ,1 20 8,1 8, , Water pressure drop Kpa 5 5 2,2 4 2,2 2,2 4 5,6 2,2 4 5, Cooling 3) kw 2,6 2,6 5 7, ,1 8,9 5 7,1 8, , , ,5 15 Coil type type WWHB7-4 WWHB7-4 9/4 9/4 9/4 9/4 9/4 9/4 9/4 9/4 9/4 10/4 10/4 10/4 10/4 10/4 10/4 10/4 10/4 Static pressure loss Pa Water pressure drop Kpa 1,0 1,0 2,3 4,3 2,3 2,3 4,3 6,3 2,3 4,3 6,3 3,7 9,4 3,7 3,7 9,4 3,7 9,4 15,0 Air speed m³/s 1,3 1,3 1,1 1,8 1,1 1,1 1,8 2,5 1,1 1,8 2,5 1,5 2,3 1,5 1,5 2,3 1,5 2,3 3,0 Sound 4) db(a) Motor rating W Maximum current A 0,65 1,00 2,00 2,00 2,30 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 2,30 4,00 4,00 6,00 6,00 6,00 Electrical connection V/ph/Hz 230/50/1 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/50/1 230/1/50 230/1/50 Length mm Width mm Height mm ) Flat filter, always including static pressure loss of a ½ unclean filter, maximum end resistance 100 Pa 2) LPHW flow/return conditions with an air intake temperature -7C 3) Chilled water flow/return conditions 6-12, with an air intake of 28C/60%RV 4) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Thermo Air - Product Catalogue Edition

34 CLK - FA, LBU, FC CLK - FC CLK FC-20 FC-20 FC-20 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 FC-30 Air volume m³/h Heating and cooling (external resistance) 1) Pa ,5 161, ,5 70,5 64, ,5 20, Heating only (external resistance) 1) Pa 296,5 281,5 231, ,5 130,5 99, ,5 80, Cooling only (external resistance) 1) Pa ,5 187, ,5 95,5 81, ,5 45, Fan type amount Maximum static pressure loss Pa Filter class G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 amount dimensions 500x x x x x x x x x x x x x x x x x500 Static pressure loss (clean) Pa Static pressure loss 1/2 stale Pa 56 58,5 65, ,5 64,5 59, ,5 64, Heating 3) kw 17, Coil type WWFC- 20/2 WWFC- 20/2 WWFC- 20/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 WWFC- 30/2 Static pressure loss Pa Water pressure drop Kpa , , , ,5 2 Cooling 3) kw 10 11, , , Coil type type WWFC- 20/4 WWFC- 20/4 WWFC- 20/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 WWFC- 30/4 Static pressure loss Pa Water pressure drop Kpa 4,0 4,8 6,7 7,0 10,0 13,0 10,0 7,0 10,0 13,0 5,0 6,7 8,6 5,0 6,7 8,6 11,0 Air speed m³/s 1,3 1,6 2,1 1,2 1,6 2,1 1,6 1,2 1,6 2,1 1,2 1,6 2,1 1,2 1,6 2,1 2,5 Sound 4) db(a) Motor rating W Maximum current A 3,10 3,10 3,10 3,10 3,10 3,10 2,30 2,30 2,30 2,30 4,00 4,00 4,00 6,00 6,00 6,00 6,00 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/52 230/1/53 230/1/54 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Length mm Width mm Height mm ) Flat filter, always including static pressure loss of a ½ unclean filter, maximum end resistance 100 Pa 2) LPHW flow/return conditions with an air intake temperature -7C 3) Chilled water flow/return conditions 6-12, with an air intake of 28C/60%RV 4) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Thermo Air - Product Catalogue Edition

35 CLK - FA, LBU, FC CLK - FC (contined) CLK FC-40 FC-40 FC-40 FC-40 FC-40 FC-40 FC-40 FC-40 FC-40 Air volume m³/h Heating and cooling (external resistance) 1) Pa 253, , Heating only (external resistance) 1) Pa Cooling only (external resistance) 1) Pa Fan type amount Maximum static pressure loss Pa Filter class G3 G3 G3 G3 G3 G3 G3 G3 G3 amount dimensions 500x x x x x x x x x x x x x x x x x x600 Static pressure loss (clean) Pa Static pressure loss 1/2 stale Pa Heating 3) kw Coil type WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 WWFC-40/2 Static pressure loss Pa 15, , Water pressure drop Kpa 2,2 2,2 3,2 3,7 2,2 2,2 3,2 3,7 4,1 Cooling 3) kw Coil type type WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 WWFC-30/4 Static pressure loss Pa Water pressure drop Kpa 20,0 25,0 31,0 36,0 20,0 25,0 31,0 36,0 41,0 Air speed m³/s 1,5 1,9 2,2 2,5 1,5 1,9 2,2 2,5 2,8 Sound 4) db(a) Motor rating W Maximum current A 6,20 6,20 6,20 6,20 6,20 6,20 6,20 6,20 6,20 Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Length mm Width mm Height mm ) Flat filter, always including static pressure loss of a ½ unclean filter, maximum end resistance 100 Pa 2) LPHW flow/return conditions with an air intake temperature -7C 3) Chilled water flow/return conditions 6-12, with an air intake of 28C/60%RV 4) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Thermo Air - Product Catalogue Edition

36 CLK - FA, LBU, FC CLK - FC (continued) CLK FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 FC-55 Air volume m³/h Heating and cooling (external resistance) 1) Pa Heating only (external resistance) 1) Pa Cooling only (external resistance) 1) Pa Fan type amount Maximum static pressure loss Pa Filter class G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 amount dimensions 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 400x500 (1x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) 500x500 (2x) Static pressure loss (clean) Pa Static pressure loss 1/2 stale Pa Heating 3) kw Coil type WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 WWFC-55/2 Static pressure loss Pa Water pressure drop Kpa 5,7 6,4 7,2 5,7 6,4 7,2 7,9 5,7 6,4 7,2 7,9 8,7 9,4 Cooling 3) kw Coil type type WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 WWFC-55/4 Static pressure loss Pa Water pressure drop Kpa 6,6 7,6 8,6 6,6 7,6 8,6 9,6 6,6 7,6 8,6 9,6 10,6 130,2 Air speed m³/s 1,9 2,1 2,4 1,9 2,1 2,4 2,6 1,9 2,1 2,4 2,6 2,6 3,1 Sound 4) db(a) Motor rating W Maximum current A 6,2 6,2 6, Electrical connection V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Length mm Width mm Height mm ) Flat filter, always including static pressure loss of a ½ unclean filter, maximum end resistance 100 Pa 2) LPHW flow/return conditions with an air intake temperature -7C 3) Chilled water flow/return conditions 6-12, with an air intake of 28C/60%RV 4) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Thermo Air - Product Catalogue Edition

37 VENTILATORS DIRECT DRIVEN CENTRIFUGAL FANS DD / DS Air volume from 100 to 7000 m³/h Multi purpose application Speed controllable Extremely silent operation Description DD/DS-centrifugal fans are double or single inlet directly driven fans with forward curved impeller blades. Fitted with counter flow fans, these classic fans are versatile and very reliable. Codering DD/DS-fans are available in 22 models. DD / 3 Standaard Supplied with: impeller with forward curved blades motor condensator separate mounting foot maintenance free bearings Amount of positions of the fan Width of the blades (mm) Diameter of the blades (mm) Direct driven, double air inlet Measurements DD Speed (x100) Width of the blades (inch) Diameter of the blades (inch) Direct driven, double air inlet DS 9-7 Width of the blades (inch) Diameter of the blades (inch) Direct driven, single air inlet DD / DDEC with double inlet DS with single inlet Technical specifications The impeller blades are constructed of aluminium steel plating or dipped steel. They are dynamically balanced and directly fitted to the motor axle. The spiralled casing is constructed of heavy galvanised steel. A vibration free and silent operation is guaranteed with the anti-vibration rubbers and an optimised blade balance. These fans are speed controllable and flexible to install in four outlet positions using the mounting foot. These fans comply with the following standards/requirements Machine Directive 89/336 EC, attachment 2B Low Voltage Directive 73/23/EEC Protection class 1, following EN 50178, EN Protection type IP 44 Dimensions Model A B C D E DD / DD DD DD DD DD DD DD DD DD Thermo Air - Product Catalogue Edition

38 DIRECT DRIVEN CENTRIFUGAL FANS DD / DS Technical data direct driven centrifugal fans DD Ventilator selection curves DD Unit DD /3 DD DD DD DD DD DD Motor rating W Speed rev. / min Maximum current A 0,65 0,60 1,00 2,00 3,10 2,30 3,10 Sound pressure 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external resistance Pa Weight Kg Speed controllable - yes yes yes yes yes yes yes Electrical connection V/ph/Hz 230/50/1 Article number DD DD Unit DD DD DD DD DD DD Motor rating W Speed rev. / min Maximum current A 2,30 2,30 4,00 6,00 6,00 7,00 Sound pressure 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external resistance Pa Weight Kg Speed controllable - yes yes yes consult consult consult Electrical connection V/ph/Hz 230/50/1 Article number DD Product Options Direct driven centifugal fans DD Type DD-180- DD DD DD DD DD DD DD DD DD DD-10- DD-11- DD / Speed controller TRK Maintenance switch WS Thermo Air - Product Catalogue Edition

39 DIRECT DRIVEN CENTRIFUGAL FANS DD / DS Technical data direct driven centifigal fans DS Ventilator selection curves DS Unit DS-7-6 DS-7-4 DS-9-6 DS-9-4 Motor rating W Speed rev. / min Maximum current A 0,60 1,00 0,60 1,00 Sound pressure 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external resistance Pa Weight Kg Speed controllable - yes yes yes yes Electrical connection V/ph/Hz 230/50/1 Article number DS DS Unit DS-10-6 DS-10-4 DS-11-6 DS-11-4 DS-12-6 Motor rating W Speed rev. / min Maximum current A 1,20 3,10 2,90 3,70 4,00 Sound pressure 1) db(a) Minimum Air volume m³/h Maximum Air volume graph Minimum external resistance Pa Weight Kg Speed controllable - yes yes yes yes yes Electrical connection V/ph/Hz 230/50/1 Article number DS ) Sound pressure measured at 3 metre distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) 2) In consultation Product Options Direct driven centifigal fans DS Soort DS-7-6 DS-7-4 DS-9-6 DS-9-4 DS-10-6 DS-10-4 DS-11-6 DS-11-4 DS-12-6 Speed controller TRK Maintenance switch WS Thermo Air - Product Catalogue Edition

40 VENTILATORS HIGH EFFICIENCY DIRECT DRIVEN CENTRIFUGAL FANS DDEC Air volume from 350 to 4500 m³/h Energy saving Speed controllable Extremely silent operation Energy Saving With these new generation DDEC high efficiency fans you never use more energy than necessary. This brushless direct current motor in combination with electronic regulation utilises far less energy than conventional motors. These constant volume fans have a high efficiency rating of 70-80% at any speed. Define the energy saving? See NEN NEN Function Fan regulation lowers the speed and torque of the motor to the actual pressure loss, which causes the low energy usage. In these situations a conventional motor goes to the working point where the ventilation curve and system curve cross each other, which results in higher energy usage. Standaard Supplied with: impeller with forward curved blades separately supplied mounting foot fan regulation low voltage regulation built in EMC-filter (no disturbance to other machinery) overload protection maintenance free bearings Codes DDEC-fans are available in 4 models, for every application. DD EC 9-7 Width of the blades (inch) Dimension of the blades (inch) Direct current Direct driven, double air inlet Technical specifications DDEC-centrifugal fans are double inlet suction fans with forward curving impellers. The impeller blades are constructed of aluminium steel plating or dipped steel. They are dynamically balanced and directly fitted to the motor axle. The spiralled casing is constructed of heavy galvanised steel. A vibration free and silent operation is guaranteed with the anti-vibration dampers and an optimised blade balance. These fans are flexible to install in four outlet positions using the mounting foot. These fans comply with the following standards/demands: Machine Directive 89/336 EC, attachment 2B Low Voltage Directive 73/23/EEC Protection class 1, following EN 50178, EN Protection type IP Thermo Air - Product Catalogue Edition

41 HIGH EFFICIENCY DIRECT DRIVEN CENTRIFUGAL FANS DDEC Technical data High efficiency direct driven centrifugal fans DDEC Unit DDEC-9-7 DDEC-9-9 DDEC DDEC Motor rating W Speed rev. / min Motor current Minimum A 0,57 1,36 2,15 4,40 Maximum A 2,4 3,7 6,4 7,4 Sound pressure Minimum db(a) Maximum db(a) Air volume Minimum m³/h Maximum m³/h External resistance Minimum Pa Maximum Pa Weight Kg Electrical connection V/ph/Hz 230/1/50 Article number DDEC ) Sound pressure measured at 3 metres distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product Options High efficiency direct driven centrifugal fan DDEC Options Type DDEC-9-7 DDEC-9-9 DDEC DDEC step switch, unipolar DDEC-ST step switch, bipolar 1) DDEC-ST Concealed box for 3-step switch OD ) For connecting two DDEC fans to 1 switch Measurements DD / DDEC with double inlet DS with single inlet Dimensions Model A B C D E DDEC DDEC DDEC DDEC Thermo Air - Product Catalogue Edition

42 VENTILATORS DIRECT DRIVEN CENTRIFUGAL FANS DDE(B) / EM Air volume from to m³/h Direct driven centrifugal fans Motors outside the air stream Forward and backward curved impellers Speed controllable Description IMOFA, a partner of Thermo Air, has been designing and producing fans for more that 25 years. This experience has steered the development of the DDEM direct driven centrifugal fans. These fans have been specifically designed for application in compact areas. They are single inlet suction fans and are available in both forward and backward curved impeller models. The electric motor is fitted directly to the fan impeller. Maintenance is effortless as the motor is placed outside the air steam. Codes DDE(B) / EM Supplied with: fitted electric motor fully balanced impeller speed controller (optional) Motor rating (kw) Phase amount of the motor (pieces) Type fan Electric motor (fitted) Forward or backward curved impellers (B = backward) Type fan Technical specifications Casing: the standard casing is welded galvanised. If required, the fans may be supplied with an epoxy-coated protection. Impellers: depending on the diameter, temperature and air volume, the blade fins are constructed of polypropylene, polyamide, aluminium or steel. All fans are supplied fully balanced and suited to operating in air temperatures up to 80 ºC. Motors: Protection degree: IP55, Electrical connection: 230 V, 380 V, 400 V Frequency: 50 Hz Environmental temperature: -15 ºC to +40 ºC. Insulation class: F These fans comply with the following standards/demands: Machine Directive 89/336 EC, attachment 2B Low Voltage Directive 73/23/EEC and 89/392/EEC ISO and IEC Directives Motor protection IP 54 or IP Thermo Air - Product Catalogue Edition

43 DIRECT DRIVEN CENTRIFUGAL FANS DDE(B) / EM Technical data DDE/EM forward curved impeller Direct driven, forward curved impeller, counter flow motor DDE / EM Unit Fan type Maximum air m³/h volume Maximum external graph resistance Type motor type 71B4 80A4 80B4 90S4 90S4 90L4 100LA4 100LB4 Pole count Motor rating W Speed rev. / min Maximum current A 1,2 1,7 2,1 3,0 3,0 3,7 5,0 7,1 Sound 1) db(a) table table table table table table table table Weight Kg Electrical connection V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Article number DDE / EM ) Sound pressure measured at 3 metres distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product Options Flanges, transition pieces from rectangular to circular, special coating or other motor types (Ex or ATEX) available on request Thermo Air - Product Catalogue Edition

44 DIRECT DRIVEN CENTRIFUGAL FANS DDE(B) / EM Technical data DDEB/EM backward curved impeller Direct driven, backward curved impeller, counter flow motor DDEB / EM Unit Fan type Maximum air m³/h volume Maximum external graph resistance Type motor type 71A2 71A2 71A2 71B2 80B2 90L2 112M2 80A4 80B4 Pole count Motor rating W Speed rev. / min Maximum current A 0,95 0,95 0,95 1,35 2,6 4,4 7,6 1,7 2,1 Sound 1) db(a) table table table table table table table table table Weight Kg Electrical V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 connection Article number DDEB / EM ) Sound pressure measured at 3 metres distance from the outlet nozzle ref 10e-12W. All values+/- 3 db(a) Product Options Flanges, transition pieces from rectangular to circular, special coating or other motor types (Ex or ATEX) available on request Thermo Air - Product Catalogue Edition

45 DIRECT DRIVEN CENTRIFUGAL FANS DDE(B) / EM Measurements DDE/EM forward curving impeller Dimensions DDE/EM with forward curved impeller Type A B C Ae E Ee F L M DDE / EM , DDE / EM , DDE / EM , DDE / EM , DDE / EM , DDE / EM , DDE / EM , DDE / EM , Measurements DDEB/EM backward curving impeller Dimensions DDEB/EM with backward curved impeller Type A B C Ae E Ee F L M DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , DDEB / EM , Thermo Air - Product Catalogue Edition

46 VENTILATOREN DIRECT DRIVEN TUBE AXIAL FLOW FAN TAX Air volume from to m³/h Direct driven fans Axial fans Speed controllable Description IMOFA, a partner of Thermo Air, has been designing and producing fans for more than 25 years. This experience has steered the development of the TAX fans. These fans have been specifically designed for application in numerous areas. The variety of dimensions, diverse motor speeds and special impellers ensure maximum flexibility for air displacement. IMOFA fans can be found in other equipment and applications as well as our own Thermo Air products. TAX fans have been specifically designed for use where confined spaces, noise level, power consumption, high temperatures and extreme circumstances are important selection criteria. These fans are available in various types of material and coatings for uses in special circumstances. Codes TAX Supplied with: fitted electric motor fully balanced blade wheel maintenance free self-lubricating bearings bearings suitable for horizontal and vertical installation insulation class F, fire resistant conform class B mounting foot (optional) Motor rating (kw) Phase amount of the motor (pieces) Dimension of the impeller blades (mm) Axial fans Technical specifications Casing: the standard casing is welded galvanised or mild steel in a long or short casing. Models Various models and configurations on request. Impellers: depending on the diameter, temperature and air volume, the blade fins are constructed of polypropylene, polyamide, aluminium or steel. The impellers are available in dimensions from 400 to 1250mm, all fully adjustable. Naturally all fans are supplied fully balanced. This is dependant of the insulation requirement (standard insulation class F and fire resistant class B1). A polyester coated finish is applied as standard. On request, special high temperature epoxy coating is also available. These fans comply with the following standards/demands: Machine Directive 89/336 EC, attachment 2B Low Voltage Directive 73/23/EEC and 89/392/EEC ISO and IEC Directives Motor protection IP 54 or IP55 On request, we will supply the technical specifications for special configurations, such as ATEX and high temperature applications Thermo Air - Product Catalogue Edition

47 VENTILATORS INDIRECT DRIVEN CENTRIFUGAL FANS HE Air volume from to m³/h Single or double inlet Forward and backward curved impellers Indirect driven centrifugal fans Speed controllable Description IMOFA, a partner of Thermo Air, has been designing and producing fans for more than 25 years. This experience has steered the development of the HE indirect driven centrifugal fans towards situations that demand quality, durability and performance in air displacement. IMOFA offers 4 main types: HE: double inlet, impellers with forward curved impeller HEB: double inlet, impellers with backward curved impeller HEE: single inlet, impellers with forward curved impeller HEBE: single inlet, impellers with backward curved impeller With the 4 types, 54 models and, a variety of impellers, configurations and motors, these fans ensure maximum flexibility for air displacement. IMOFA fans can be found in other equipment and applications as well as our own Thermo Air products. If required, these fans can be supplied compete with motor and positioned on a base frame. Various protective coatings are also available. Supplied with: dynamically balanced blade wheel steel bearing cover in rubber framework (till HE(B)(E) 315) or with cast iron bearing cover (>HE(B)(E)355) re-lubricatable bearings foundation (optional) mounting foot (optional) frequency regulator (optional) Even in situations that fall under the strict ATEX standards, such as temperature and dangerous chemicals, the HE range offers excellent possibilities. Codes HE(B)E Motor rating (kw) Type fan Double or single intake (E=single) Forward and backward curving impellers (B=backward) Model HE fan Thermo Air - Product Catalogue Edition

48 INDIRECT DRIVEN CENTRIFUGAL FANS HE Technical specifications Casing: the scroll shaped casing is constructed of robust galvanised steel. Along with the bearing speed selection and high standard blade balance, this sturdy construction guarantees a vibration free and silent operation. The standard version is supplied with outlet flange and cubed frame. Impellers: depending on the diameter, temperature and air volume, the impeller blades are constructed of robust galvanised steel or from fibreglass reinforced polyamide (HE(B)/HE(B)(E) 200 t/m 450). The impellers are all fully adjustable and are supplied dynamically balanced. Forward curving impellers in galvanised steel. Backward curving impellers type 450 in fibreglass reinforced polyamide. > type 500 in coated steel. Bearings: all ball bearings are pre-lubricated and fitted within sealed for life casings. The types fitted within a steel casing with rubber rings. The types are self-aligning bearings, fitted within a cast iron casing with grease nipples. Base frames: the base frames are constructed of thick walled, welded steel U-profiles and/or angle steel frames and finished with a special coating. Motors: the electric motors are selected per type so that the combination of fan, motor and propulsion type meets your specific requirements. The motors are also available with various motor safety devices such as PTO and PTC. Frequency regulators are also available. Examples of outlet positions HE + EM POSITIONS A to I These fans comply with the following standards/demands: Machine Directive 89/336 EC, attachment 2B Low Voltage Directive 73/23/EEC and 89/392/EEC ISO and IEC Directives Motor protection IP 54 or IP Thermo Air - Product Catalogue Edition

49 INDIRECT DRIVEN CENTRIFUGAL FANS HE Technical data HE (forward curving impeller) HE Unit HE HE HE HE HE HE HE HE HE HE HE HE HE HE HE Max. motor capacity kw 1,5 1,5 2,2 2,2 4,0 7,5 7,5 11,0 11,0 11,0 11,0 15,0 22,0 30,0 37,0 Max. Speed rev./ min Weight Kg 9,4 10,6 13,4 18,1 22,8 38,4 45,7 56,1 76,4 88,2 111,1 145,3 272,2 330,7 394,6 Other data see graphs, available separately Article number HE HEB (backward curving impeller) HEB Unit HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB HEB Max. motor capacity kw 1,5 2,2 4,0 4,0 4,0 5,5 7,5 7,5 11,0 15,0 18,5 22,0 37,0 55,0 55,0 Max. Speed rev./ min Weight Kg 8,6 10,2 13,4 16,2 19,8 36,8 43,1 52,1 88,8 108,9 156,9 189,9 285,3 355,5 433,2 Other data see graphs, available separately Article number HEB HEE (forward curving impeller, single inlet) HEE Unit HEE 280 HEE 315 HEE 355 HEE 400 HEE 450 HEE 500 HEE 560 HEE 630 HEE 710 HEE 800 HEE 900 HEE 1000 Max. motor capacity kw 2,2 4,0 5,5 5,5 7,5 7,5 11,0 11,0 15,0 18,5 22,0 30,0 Max. Speed rev./ min Weight Kg 14,4 17,1 30, ,5 59,5 71,9 91,2 111,2 199, Other data see graphs, available separately Article number HEE HEBE (backward curving impeller, single inlet) HEBE Unit HEBE 280 HEBE 315 HEBE 355 HEBE 400 HEBE 450 HEBE 500 HEBE 560 HEBE 630 HEBE 710 HEBE 800 HEBE 900 HEBE 1000 Max. motor capacity kw 2,2 2,2 3,0 3,0 4,0 7,5 11,0 11,0 18,5 18,5 30,0 37,0 Max. Speed rev./ min Weight Kg Other data see graphs, available separately Article number HEBE Product Options Installation on a base frame complete with motor, v-belt and protective cover are some of the possibilities. These fans are also available in a EX or ATEX version. Available with a protective coating as well as transition pieces from rectangular to circular. A spark minimising version is not applicable for HEB / HEBE type 200 to 450. These are fitted standard with polyamide impellers. Dimensions for the vibration damper are dependant on the HE fan type. Dimensions (DxH) type A = 30x20-M8 ;type B= 50 x 30-M10 mm. Type A : =< HE-560 of HEB-450 and motor =< 4.0 kw Type B: => HE-630 or HEB 500 and motor => 5.5 kw Thermo Air - Product Catalogue Edition

50 INDIRECT DRIVEN CENTRIFUGAL FANS HE Measurements HE / HEB / HEE / HEBE Dimensions HE / HEB HE(B) fans, double inlet (forward or backward curving impellers) HE, HEB A B C E f h (10x16) (10x16) (10x16) (10x16) (10x16) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) ii j k l m n v w d t 22,8 22,8 22, u Dimensions HEE / HEBE HE(B)E fans, single inlet (forward or backward curving impellers) HEE, HEBE A B C E f h (10x16) (10x16) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) (12x20) ii j k l m n v w v w d t u Thermo Air - Product Catalogue Edition

51 AIR HANDLING, AIR TREATMENT CABINETS LBK - CONCEPT Sandwich panel-construction Air volume from 100 to m³/h Cooling / heating / heat recovery / humidifying / mixing / ventilation Customised according to your specifications Three construction methods with maximum flexibility Description The importance of a comfortable indoor climate is often underestimated. As producers of air handling units, we can supply any concept of air handling and climate control equipment that is required. Ventilation, heating, cooling, humidifying, dehumidifying and heat recovery are some of these possibilities. Welded frame- construction For heat recovery we utilise high efficiency cross flow heat exchanger, twin coil systems, heat wheels and heat pipes. Also possible is StatiqCooling, a new energy saving method of cooling with water without a cooling machine. Every air handling unit can be assembled according to your wishes, without being bound to measurements. Our staff will be happy to inform you of the possibilities. Air volume, process, external resistance, filters, dimensions, sound, energy use etc. will all be taken into consideration to help you make your final choice. Pentapost- construction To realise this, we at Thermo Air, have designed three construction types to produce air handling units for every process. A. Welded frame- construction B. Pentapost- construction C. Sandwich panel-construction Every construction method has its own specific application areas. As standard, we have designed a number of modules with which we can build up our air handling units. The process determines which construction method and module should be applied. With these models and dimensions, we can provide you with any type of airhandling unit you require. Given its air volume and matching dimensions, the 30SP type is a speciality product that is only available on request. Pentapost- construction Thermo Air - Product Catalogue Edition

52 LBK - CONCEPT Construction types A. Welded frame-construction Constructed of a fully welded frame with single walled or double walled insulated plating. Sendzimir galvanised plating material is applied as standard. Available in pre-coated colours such as RAL 9010, 9001, 7035, other colours available on request. This construction method is frequently used for ventilation and industrial heating processes such as spraying cabinets or oil/gas fired air heaters. C. Self supporting sandwich-construction Completely manufactured from self supporting sandwich panels (with a standard width of 40 mm). This construction type is suitable for larger air volumes and dimensions, as well as special application ranges. The self supporting PIR/PUR panels have a closed cel structure and are galvanised on both sides with an RAL 7035 polyester coating. Other colours are available on request. The welded frame construction guarantees you a robust and sturdy air handling unit. A significant advantage of this construction type is the availability of practical modules. This construction is suitable for indoor and outdoor installation. All sandwich panel constructed units are single, complete units. They are therefore applied in the larger and more complex air handling units. Sandwich panels are available in various panel widths. B. Aluminum pentapost-construction Aluminium angle profile with single or double walled insulated plating, with an insulation width of 20 to 50 mm. The galvanised steel plating material is supplied standard in the colour RAL It is also available in pre-coated panels in the colours RAL 9010 and 9001 or customer specific colours. This construction type has been chosen by us because of its high quality and fast production time. It is suitable for use in all processes for climate control. With its modular structure the pentapost construction is of appealing design which makes it suitable for indoor or outdoor installation. Their robust and deluxe design can be attributed from the UNP-profile mounting, the high inusulation degree and the stainless steel protection profiles Thermo Air - Product Catalogue Edition

53 LBK - CONCEPT Sandwich panel-construction Types The LBK-range contains the following models: Model Air volume (m³/h) Module (hxw) (mm) SP > *) *) *) on request Possibilities Every LBK uses an IMOFA HE(B) or a direct driven DD fan. These powerful and quiet fans form the heart of every unit. Below you will find a concise summary of the possibilities of our LBK range. filtering ventilation heating (oil or gas fired, warm water) cooling (direct expansion, chilled water, adiabatic cooling) mixing air supply and extraction heat recovery (cross flow heat exchangers, heat wheels, twin coils) air humidifiers (steam, ultrasonic) complete regulation (temperature regulation with sensors) mains/maintenance switches (fitted) sound dampers frequency regulators (supplied separately) filter pollution detection, such as gauge points, magnehelic and minihelic. mesh. This produces the perfect air handling units for outdoor installation. Selection table Standard information for the LBK range can be found in the selection table. This enables you to directly choose the LBK type suitable for your situation. The table includes a selection of our standard heat coils, however, we can also help you select customized heat coils due to our expertise and selection software. Special conditions For applications with special requirements, such as the ATEX standard and/or high temperature applications, we can apply certified components to the LBK range. Our advisors are happy to advise you of the possibilities. Compliance as per the Standards stated in Machine Directive 89/336 EC (attachment 2B) and the Low Voltage Directive 73/23/EEC. Base frame All Thermo Air air handling units are supplied with a base frame or self supporting profile. The units are also supplied as a complete unit including hoisting hooks. This reduces on site installation time. If you have limited space, we can also supply the unit in separate components. Set-up Our air handling units are suitable for indoor or outdoor installation. For the outdoor model, we supply an overhanging roof strip, durable roof finishing and a weather cowl with bird Thermo Air - Product Catalogue Edition

54 LBK - CONCEPT Technical data Air handling LBK concept Heating Heating Heating Heating Cooling Air volume Air speed Capacity Air intake resistance Capacity Air intake resistance Capacity Air intake resistance Capacity Air intake resistance Direct expansion Air intake resistance 1-row 1-row 2-rows 2-rows 3-rows 3-rows 4-rows 4-rows 4-rows 4-rows Type m³/h m/s kw Pa kw Pa kw Pa kw Pa kw Pa LBK ,11 3, ,5 21 LBK ,17 4, ,5 45 LBK ,22 4,8 18 9, LBK ,28 5, LBK ,33 5, LBK ,39 6, LBK ,17 5,6 4 9, ,7 21 LBK ,22 6,6 7 11, ,5 16 8,2 35 LBK ,28 7, ,5 20,5 27 9,4 51 LBK ,33 8, , , , ,5 70 LBK ,39 9, , , ,5 92 LBK ,44 9, , , ,5 70 LBK ,50 10, , , ,5 89 LBK ,56 10, , , ,6 109 LBK ,61 11, , ,6 131 LBK ,67 11, , ,5 154 LBK ,33 11, LBK ,44 12, LBK , ,5 58 LBK ,67 15, , ,2 71 LBK , ,5 85 LBK , , LBK , , ,5 164 LBK , , LBK , , LBK , ,5 48 LBK ,89 20, , , LBK , , LBK , LBK , LBK ,33 25, ,5 96 LBK ,44 26, , LBK ,56 27, LBK , LBK , LBK , LBK , , LBK ,11 30,5 8 56, , LBK ,33 33, , LBK ,56 36, LBK , LBK , , LBK , , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , LBK , ) Warm water trajectory 80-60ºC, air intake condition -7ºC 2) Cold water trajectory 6-12ºC, air intake condition +28ºC / 60% RV Thermo Air - Product Catalogue Edition

55 LBK - CONCEPT Cooling Flat filter Bag filter Bag filter Bag filter Class G3 Class G4 Class F5 Class F7 Air speed Cold water Air side resistance Air speed Resistance Resistance Resistance Resistance Resistance Resistance Resistance Resistance 4-rows 4-rows 4-rows 4-rows Clean 1/2 polluted Clean 1/2 polluted Clean 1/2 polluted Clean 1/2 polluted m/s kw Pa m/s Pa Pa Pa Pa Pa Pa Pa Pa 4) 2,6 27 1,3 9 54,5 4) 3,5 55 1, ,5 4) 4,1 91 2, , ,1 3,5 55 1, , , ,8 4, , ,2 4) ,5 4) ,4 9,5 38 1, ,6 11, ,8 13,5 92 2, ,1 15, ,3 4) , , , , , , ,5 24,5 91 2, ) ,2 26,5 26 1, , , , , , , , , , , , , , , , , ,8 73, , , , , , , , , , , , , ) End resistance G4, 250 Pa; Fkz5, 250 Pa; Fkz7, 250 Pa 4) Available onn request 2007 Thermo Air - Product Catalogue Edition

56 SPECIAL PROJECTS MOBILE AIR HANDLING Adapted sea containers for 350 kw mobile cooling capacity Thermo Air is an internationally known specialist in the design and production of mobile air handling equipment. Various large companies that supply global temporary solutions for power, cooling and climate control make use of our products. Significant Events Our speciality is providing made to measure solutions for temporary situations. Imagine the air conditioning units that are required for large or significant events. For example, Golf Tournaments, Grand Prix, The Olympic Games, World Summits, World Cup or European Cup Soccer and Film Studios. Without realizing it, you have probably already come in contact with our Fan Coil or other mobile units. Mobile air handling 150 kw, welded frame construction Everything is customised There is no standard product for these solutions: everything is customised. After all, every customer has his own specific requirements: special casing, various hoisting features and complete electronic regulation. From small units that speed up during applause in a hall, to 20 ft. sea containers that are adapted to air handling units. These units all have one thing in common: they all work with the plug & play concept. Ultimately, these units must be operational as soon as possible. Need more information? Please do not hesitate to contact us. Mobile boilers with 250 kw heating capacity Thermo Air - Product Catalogue Edition

57 COMPONENTS ELECTRIC MOTORS EM Description All motors from our selection are produced following the ISO 9001 quality system. The motors comply with the following: Application: Industry Protection degree: IP55 Electrical connection: 230 V, 380 V, 400 V Frequency: 50 Hz Environmental temperature: -15 ºC to +40 ºC Insulation class: F We also supply motors for special voltages, other frequencies and high protection degree (i.e. IP65). There are also various possibilities for application in special circumstances such as explosion proof and high temperatures. Our motors are supplied with temperature monitoring (Klixon, PTO, PTC). Technical specifications Frame, housing and electronic connection box are constructed of cast iron or aluminium AK11. The external fan is constructed of thermoplastic material, the fan casing from steel. Models 1- Phase motors: 4-pole (max. speed 1500 n -1 ) 1- Phase motors: 2- pole (max. speed 3000 n -1 ) 1- Phase motors: 4- pole, (max. speed 1500 n -1 ) 1- Phase motors: 2- pole (max. speed 3000 n -1 ) 2-Speed motors (DAHLANDER): 8/4 pole, speed 750/1500 n Speed motors (DAHLANDER): 4/2 pole, speed 1500/3000 n Thermo Air - Product Catalogue Edition

58 COMPONENTS HEAT AND COOLING COILS Available from stock Heating or cooling from 5 to 1000 kw Cold water / warm water / direct expansion (DX) / steam / electric Customised and standard dimensions Description Heat Exchangers are used in our own air handling products but can also be applied in various other situations (for example built into ducting). The special design ensures a maximum heat transfer. Standard models are constructed of copper tubing and aluminium fins in a galvanised steel frame. Coils can be supplied partly or completely coated. We also supply built in electric elements (on request). Thanks to special software, we can select the correct coils to meet customer specifications. The possible selections are cold or warm water, steam and of course all available refrigerants such as R22, R407C, R410A, R134A etc. Coils are also available in other materials such as copper, aluminium, copper nickel, stainless steel and combinations of these materials with eventual coating. Our standard models have a fin spacing of 2.54 mm but this can be customised on request. Types Thermo Air has the following coil types: standard dimensions, in stock customised for every situation Supplied with (standard heat exchangers): Optimal heat distribution Copper piping Aluminium fins Galvanised frame With or without coating Table In the tables you will find a summary of our standard heat coils. Because of the various possibilities available we advise you to contact our sales team. They will be happy to assist you in choosing the correct heat coil. Because of the various range of heat coils we have in stock, in general we deliver immediately. Customer specific heat coils are available of request. Technical specifications All standard heat coils have a fin spacing of 2.54 mm. Every coil is tested under water and at a pressure of 24 bar (2,4 MPa). Higher pressures or other materials are also available. Codes All heat coils of the type HB can be built in a half module as shown in the table below. HB (type) Half Module (mm) x x x x x x x Thermo Air - Product Catalogue Edition

59 HEAT AND COOLING COILS Product data Heat and cooling coils DX Type Model Article no. WWFA U WWFC 20 4 U WWFC 30 4 U WWFC 40 4 U WWFC 55 4 U WWHB 9 4 T WWHB 10 4 T WWHB 12 4 T WWHB 15 4 T WWHB 18 4 T WWHB 25 4 T Steam coils Type Model Article no. SBHB 10 1 S SBHB 12 1 S SBHB 15 1 S SBHB 18 1 S SBHB 25 1 S SBHB 12 2 S SBHB 15 2 S SBHB 18 2 S Heating and cooling coils Type Model Article no. WWFA U WWFC 20 4 U WWFC 30 4 U WWFC 40 4 U WWFC 55 4 U WWHB 7 4 T WWHB 9 4 T WWHB 10 4 T WWHB 12 4 T WWHB 15 4 T WWHB 18 4 T WWHB 25 4 T Thermo Air - Product Catalogue Edition

60 HEAT AND COOLING COILS Heating coils Type Model Article no. WWFA U WWFA U WWLG 2 U WWVC U WWVC U WWVC U WWVC U WWFC 20 2 U WWFC 30 2 U WWFC 40 2 U WWFC 55 2 U WWHB 7 1 T WWHB 7 2 T WWHB 9 1 T WWHB 9 2 T WWHB 9 3 T WWHB 10 1 T WWHB 10 2 T WWHB 10 3 T WWHB 12 1 T WWHB 12 2 T WWHB 12 3 T WWHB 15 1 T WWHB 15 2 T WWHB 15 3 T WWHB 18 1 T WWHB 18 2 T WWHB 18 3 T WWHB 25 1 T WWHB 25 2 T Thermo Air - Product Catalogue Edition

61 COMPONENTS Thermo Air/IMOFA also supply various components. All filter types, various types of maintenance switches and also high efficiency chromium steel combustion chambers. We also have components for our fans in stock such as bearings, blades, motors and axles. Heat and cooling coils Frame - plating - isolation Direct fired heat coils Cross flow heat exhangers Filters Servomotors Mains/maintenance switches Electric motors Components for fans Technical data Speed controllers and maintenance switches Model B H D Weight (kg) max. nominal current (A) TRK TRK ,5 5 TRK ,3 7 TRK ,7 9 VEB ,3 4 VEB ,4 6 VEB ,5 9 3ST ,1 10 WS ,1 16 WS ,1 16 CB ,8 10 CB ,3 10 RT ,1 2 RT ,1 3 ATR ,8 3 ATR ,6 5 ATR ,1 7 ATR , Thermo Air - Product Catalogue Edition

62 COMPONENTS Measurements KRK Dimensions KRK KRK sizes in mm Letter A B C D E F G H b b No. Blade Qty h h A1 B1 C1 D1 E1 F1 G1 H A2 B2 C2 D2 E2 F2 G2 H A3 B3 C3 D3 E3 F3 G3 H A4 B4 C4 D4 E4 F4 G4 H A5 B5 C5 D5 E5 F5 G5 H A6 B6 C6 D6 E6 F6 G6 H A7 B7 C7 D7 E7 F7 G7 H A8 B8 C8 D8 E8 F8 G8 H A9 B9 C9 D9 E9 F9 G9 H A10 B10 C10 D10 E10 F10 G10 H A11 B11 C11 D11 E11 F11 G11 H A12 B12 C12 D12 E12 F12 G12 H A13 B13 C13 D13 E13 F13 G13 H13 Weight KRK KRK weight in kg Letter A B C D E F G H b b No. Blade Qty h h Thermo Air -- Product Catalogue Edition

63 Logic From now on, one control for all Thermo Air equipment: Logic { Creating the perfect environment Plug & play User and operator menus Easy management Easy to configure Various inlet and outlet Thermo Air Holland - Ambachtsweg AM Huizen - T +31 (0) F +31 (0) Thermo-Air Ireland - Strawhall, Athy Road - IRL Carlow Ireland - T F Member of the Honing Beheer Group of Companies

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

INDUSTRIAL AIR CURTAIN. IndAC 2

INDUSTRIAL AIR CURTAIN. IndAC 2 INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is

More information

DX AIR CURTAIN. SensAir

DX AIR CURTAIN. SensAir DX AIR CURTAIN SensAir Biddle and Daikin Complete climate system Since 2006 Biddle and Daikin have joined forces to provide a complete climate system for shops and public buildings. By combining Biddle

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers. ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2 AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

Recessed. Air Curtain. Fig 1. Recessed air curtain

Recessed. Air Curtain. Fig 1. Recessed air curtain the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements

More information

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications. X- StreamSystems X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications. Contact us on: 01384 455811 Visit

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery Technical documentation ComfoAir XL 800-6000 The latest generation of ventilation units with heat recovery Heating Cooling Ventilation Filtering Service and recommendations The latest heat recovery range

More information

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical

More information

PREEVA air handling unit

PREEVA air handling unit APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu

More information

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

SIMPLICITY FULL MODULARITY?

SIMPLICITY FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS OR SIMPLICITY FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

Primo Hotel. General. Indoor climate units for hotel rooms

Primo Hotel. General. Indoor climate units for hotel rooms Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without

More information

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more

More information

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology. PENDER Vario PENDER Vario Line PENDER Profi Line PENDER Air Curtains PENDER Airquell Exhaust Technology www.pender.de Our company Your manufacturer of trend-setting and efficient hall heating systems Your

More information

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

FAN COIL UNITS. The optimal solution for limited space

FAN COIL UNITS. The optimal solution for limited space FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India

More information

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units AIR CONDITIONING An air conditioned environment is increasingly expected in retail, commercial and industrial premises. Whilst there will always be a demand for custom built air conditioning the standard

More information

Optimal work climate with open doors. Industrial air curtains Model IndAC

Optimal work climate with open doors. Industrial air curtains Model IndAC Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN! WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN! FANTECH s full ranges of industrial and buiding ventilating fan widly used in industry process Plant & refrigeration, packaged air conditioner

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

energy efficient air curtains technical data and controllers

energy efficient air curtains technical data and controllers energy efficient air curtains technical data and controllers Versatile are delighted to introduce the following door curtains manufactured by LSA. LSA are a market leader in Europe in the manufacture of

More information

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc. SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers

More information

CLIMACIAT AIR COMPACT

CLIMACIAT AIR COMPACT Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000

More information

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air VARIO eco Dust Collector Standard for clean air For the highly effective, energy efficient collection of dust from industrial processes The VARIO eco series is known for low filter resistance with very

More information

Fan coil unit KL. Wall unit Ceiling unit

Fan coil unit KL. Wall unit Ceiling unit Fan coil unit KL Wall unit Ceiling unit Description Wall unit with casing, top discharge 7 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs up to 6 kw Heating/cooling

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

Systemair product news - Fans NEWS

Systemair product news - Fans NEWS Systemair product news - Fans NEWS Perfect Climate. Anywhere. Anytime Smart, energy-saving solutions for ventilation and air-conditioning. Well-thought-out system solutions for every application area.

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

42AM. Air heaters PRODUCT SELECTION DATA

42AM. Air heaters PRODUCT SELECTION DATA PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels

More information

MOBILE HOT AIR HEATING SYSTEMS

MOBILE HOT AIR HEATING SYSTEMS MOBILE HOT AIR HEATING SYSTEMS Issue 2012 Mobile hot air heating systems Mobile Heaters Heating Centers Quality with systems RAPID HEAT ADAPTED TO YOUR NEEDS Hot air heating systems for air, to feel good,

More information

PK-N Floor Standing Heater

PK-N Floor Standing Heater PK-N Floor Standing Heater The experience is mixed with technology A solution for any necessity High efficiency Heat exchanger in inox steel 55 PK-N: the heat that lasts in time Apen Group has redesigned

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

Fan Coil Unit CULTRA

Fan Coil Unit CULTRA Fan Coil Unit CULTRA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to

More information

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF New CGAF New Air-Cooled Scroll Chiller CGAF New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2 New addition to the Sintesis Family: Multiple technologies,

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

Exhaust Duct Design Page 1 of (C)

Exhaust Duct Design Page 1 of (C) Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

CHILLED ROOM AIR CURTAIN. IsolAir

CHILLED ROOM AIR CURTAIN. IsolAir CHILLED ROOM AIR CURTAIN IsolAir IsolAir chilled room air curtain Climate separation without heating Optimal climate separation The Biddle IsolAir chilled room air curtain is the perfect solution for internal

More information

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections Now includes a Pressure Safety Switch and easier Electrical Connections Flue Dilution Fans VISIT US AT www.airflow.com UK SALESLINE 0845 330 1047 Specialists in Air Movement Technology SAFETY - NEW Differential

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

TUNNEL FANS STANDARD AND HOT SMOKE

TUNNEL FANS STANDARD AND HOT SMOKE TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

VEX250H with rotary heat exchanger and EXact control system

VEX250H with rotary heat exchanger and EXact control system 3003433-2014-04-11 VEX250_EXact VEX250H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): Compact filter FP Filter bag FB Trim damper and blowout zone,tb250 The following

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans The Silent Range Pure Elegance & Tranquillity The widest range of ultra quiet silent fans The most advanced SILENT technology delivering the highest extract performance. 1 Your first choice for ventilation

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems, industrial processes,

More information

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

Products and prices. CLIMATE TECHNOLOGY feels better, works better. Products and prices CLIMATE TECHNOLOGY feels better, works better. www.markclimate.com Long-term leaders in climate management Get to know the specialist in the Netherlands in the field of air heating,

More information

Air Handling Units. direct drive - belt drive - custom built

Air Handling Units. direct drive - belt drive - custom built for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;

More information