42AM. Air heaters PRODUCT SELECTION DATA

Size: px
Start display at page:

Download "42AM. Air heaters PRODUCT SELECTION DATA"

Transcription

1 PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of the original document 0040,

2 Use In wall-mounted or ceiling-mounted versions, the air heater is the simple, affordable heating/cooling solution for all your applications: for your premises in the tertiary sector (sales area, gym, multi-purpose rooms etc.) or in industry (workshop, garage, storage unit, logistics platform, etc.). The 4AM range meets APSAD and NFPA recommendations on unit peripheral air speeds. Options and accessories - Wall bracket, ceiling bracket, IPN additional kit - Filter box - -channel mixing box with built-in filter - Specific diffuser (on door, high-level etc.) All are less than 5 m/s at 0.5 m from the diffuser and thus do not interfere with sprinkler systems. The air heater may have associated destratifiers (4AMA-) to promote mixing of the building air. (Anti-stratification solution). Destratifier determination and selection example S = Supply (released at the top of the building) TR = Temperature under roof TW = Temperature setpoint in the work area A Calculated flow rate for destratifiers = 0. x (TR-TW) Control A range of "Plug & Play" proportional air-source/watersource controllers with heat exchanger (or electric heater) are used to control the air flow of the fan motor assembly and the heating capacity required for the room, according to the occupancy periods (built-in timer). Range Selection example: Supply under building roof = S = 45,000 kcal (5,00 Watts) Temperature under roof = TR = 0 C Temperature setpoint in the work area = TW = 6 C Calculated flow rate for destratifiers = x (0-6) = 074 /h m Either: X 4AMA-50---T0 at or x 4AMA-6---T0 at. LP water + -PH HEE FMA with EC motor application: -PH EC BOX can control x 4AM-- -PH with EC motor + x 4AMA- -PH with EC motor or 6 x 4AM-- -PH with EC motor or 6 x 4AMA- -PH with EC motor. - Damper and outdoor kit - Room thermostat for THREE-PHASE or SINGLE-PHASE installation - / switch for -PH FMA - 5 speed autotransformer for SINGLE-PHASE AC FMA Heating/cooling medium Standard drive Coil (tubing/row) Water THREE-PHASE speeds SINGLE-PHASE variable speed IP44/54 depending on the model Copper/Alu Casing Operating principle Precoated off-white (RAL 705) galvanised steel Condensate pan + built-in nautical coupling for cooling Standard Air heaters are installed at the end of a central heating or cooling system (boilers, air-source or water-source heat pump, reversible production unit).

3 Description High-efficiency fan motor assembly Silent FMA featuring an aluminium epoxy polyester-coated airfoil propeller to ensure the best compromise between air flow efficiency and acoustic comfort. The ROTOREX design (windings inserted in the fan hub) keeps the motor cool to ensure that it operates at optimum efficiency. Three versions are available : THREE-PHASE speeds (accessory: / switch) SINGLE-PHASE variable speed (accessory: 5-speed autotransformer) Low consumption EC FMA Fan motor assembly equipped with a powerful high-efficiency EC (electronically commutated) motor. These EC motors (single-phase 0 V drive) will be progressively controlled by the 0-0 V signal, to ensure acoustic comfort and air flow efficiency and to optimise consumption of electricity. A shunt can be used to operate the air heater at maximum speed. Casing Elegant galvanised steel casing, pre-painted with RAL 705 (light grey). Condensate drain pan built-in for cooling applications, featuring an antibacterial design (perforated bottom) and quick-release fitting. Intake section optimised for improved air flow performance and acoustic comfort level. Advantages: - Its classic design means that it can easily blend into the architecture of the installation site. - No need to add an unsightly condensate drain pan. - Condensate pipes quick and extremely simple to connect, without any need for a clamp. Heat exchanger HIGH EFFICIENCY heat exchanger coil with tapered intake baffles, to help pressurise the finned block, available in four versions: - LP hot or cold water version Available with, or rows: Copper tube Ø 9.5 mm Embossed aluminium fins Thickness 0/00 mm Fin spacing. mm Equilateral geometry mm Advantage: Excellent thermal yield (dry transfer coefficient > 50 W/m².k) Family Size No. of rows Function Coil type Motor type Position of hydraulic connections Diffuser Double deflection diffuser made from rigid aluminium sections, based on the BERNOULLI fluid flow principle and on NACA00 airfoils, creating a high induction rate on the primary air, in order to increase the air throws, limit the stratification phenomenon and thereby reduce energy consumption. - Basic version (only for the 4AMS-6H0T0LR): Single-deflection diffuser with directional louvre Light-grey galvanised steel louvre - JET+ version (fitted as standard): Double deflection diffuser JET+ aluminium louvre with NACA00 airfoil design Each louvre is directional Advantages: - Air flows adjustable in 4 directions for optimum coverage of the area to be handled, while limiting draughts. - Laminar air flow for better acoustic comfort (zero turbulence at the diffuser outlet). - Increased air speed, thanks to the resulting aerodynamics (depression along lower surface of blade) due to the curve of the airfoil, thereby increasing the air throws and the induction rate. - Limited stratification phenomenon. - Reduced building warm-up times: - Recorded energy savings of 5 to 0%. 4AM- 0 - H 0 M0 LR 4AMS- 5 C M9 RI 4AMA- 40 T0 LE Family: 4AM Size: 5 to 6 Number of rows: - = Ventilation only (4AMA), = row, = rows, = rows Function: H = Hot water, C = Cold water/hot water & cold water Coil type: 0: STANDARD, :STAINLESS STEEL (on request) Motor type: M0 = 0V single-phase with AC motor, M9 = 0V single-phase with EC motor, T0 = 400V three-phase with AC motor Hydraulic connection positions: LR = Left and right, LE = Left, RI = Right Example: AM--5H0M9LR Family: 4AM-- Size: 5 Number of rows: Function: H (Hot Water) Coil type: 0 (Standard) Motor: M9 (0V single-phase with EC motor) Hydraulic connection positions: LR (Left and right)

4 Comparative study of AC and EC FMAs Study comparing two air heaters in heating mode, () an AIR HEATER fitted with an AC FMA (without JET+ diffuser) and () an AIR HEATER fitted with an EC FMA (with JET+ diffuser). Space volume: 40 m² under 5 metres of ceiling, i.e. 600 m Type of insulation: light (such as in a workshop or small distribution centre) Temperature to be maintained in occupied space: 7 C Average outdoor temperature used: 5 C Heating period: November to March Heating time range: from to 9.00 Necessary heating capacity: 80W/m² i.e. 99. kw (at 5 C) AIR HEATER WITH AC FMA Mixing rate: 6 (or 7,00 m /h to be provided) Unit selected: - 6 x 4AM--50H0T0LR Total flow rate supplied = 7,00 m /h Total heating capacity delivered = 94 kwh Total price of air heaters COST OF INSTALLATION HELIOTHERME WITH EC FMA Mixing rate: 4 (or 4,800 m /h to be provided) (Lower rate achieved by adjusting the air flow via the 0-0 V signal of the FMA connected to the EC BOX) Unit selected: - 6 x 4AM--45H0M9LR Total flow rate supplied = 4,800 m /h Total heating capacity delivered = 46 kwh Total price of air heaters ECO+ -PH BOX control + installation costs 78 OPERATING COST Plug & Play EC BOX control 480 Basis for analysis: Energy price assessed according to the Pegase database for energy statistics Total number of heating days = 00 (0 per month from November to March) Running time needed each day to maintain 7 C in the comfort zone Running time needed each day to maintain 7 C in the comfort zone 960 minutes a day i.e. 600 hours per year 58,70 kw of boiler power used Annual heating expenses Annual electricity expenses for AC FMA 760 minutes a day i.e. 68 hours per year: 4 hours at maximum power and 845 hours at half / flow power (or a saving of hours of operation) 5,786 kw of boiler power used Annual heating expenses (savings of 5%) Annual electricity expenses for EC FMA (savings of 60%) Total annual expenses,09 Total annual expenses (savings of 0%) 9,068

5 Single-phase 4AM performance Size No. rows HEATING - SINGLE-PHASE AC motor and SINGLE-PHASE EC motor Sound Air supply speed Flow rate Air speed Throw (metres) pressure SINGLE PHASE m /h m/s Wall-mounted Suspended db(a) m/s m/s m/s m/s 5, m/s m/s m/s 5, m/s 4 7, m/s 6 8, m/s 9 4, m/s m/s 0 5, m/s m/s m/s 7 8, m/s m/s 4, m/s m/s 8, m/s m/s m/s m/s m/s 5, m/s 4 6, m/s m/s 8 0, m/s m/s 4 8, m/s 6, m/s HEATING - COOLING - SINGLE-PHASE AC motor and SINGLE-PHASE EC motor Air flow rate Air speed Throw (metres) Sound pressure Size No. rows Air supply speed m /h m/s Wall-mounted db(a) 5M0 (AC) m/s 0 40M0 (AC) 60.5 m/s M0 (AC) m/s M0 (AC) m/s 54 6M0 (AC) 0M9 (EC) m/s 4 5M9 (EC) m/s 0 40M9 (EC) 60.5 m/s M9 (EC) m/s M9 (EC) m/s 54 6M9 (EC) m/s 5 Specifications determined using the following information : Air throw: * with JET+ diffuser for a residual speed of 0. m/s * defined with êt OT/RT of 5 C (heating) and 7 C (cooling) * with LP water or electric heating Air speed: JET+ diffuser outlet Sound pressure: measured 5 metres from unit, directivity, attenuation of db : speed obtained when wired directly to single-phase motor. : supply air speed obtained with autotransformer set to "". Other operation points (5 in total) can be supplied on request by your agent using our technical selection software. 4

6 Three-phase 4AM performance Model Specifications determined using the following information : Air throw: No. row(s) 6S Air speed: Sound pressure: HEATING - THREE-PHASE motor Air supply speed Flow rate Air speed Throw (metres) * with JET+ diffuser for a residual speed of 0. m/s * defined with êt OT/RT of 5 C * with LP water or electric heating JET+ diffuser outlet measured 5 metres from unit, directivity, attenuation of db Sound pressure -PH m /h m/s Wall-mounted Suspended db(a) ê m/s m/s 7,5 44 ê m/s m/s 5,5 45 ê 65.6 m/s 8 4, m/s 4 46 ê m/s m/s 5 5 ê m/s m/s ê m/s 6, m/s 7,5 5 ê m/s m/s 5,5 49 ê m/s m/s 4,5 50 ê m/s 4 7, m/s ê m/s m/s ê m/s m/s ê m/s 6 8, m/s 5,5 5 ê m/s 9, m/s 4 8,5 48 ê m/s 6 0, m/s 7,5 49 ê m/s m/s 7 49 ê m/s 9, m/s 4 8,5 48 4AMA- air flow & acoustic performance THREE-PHASE motor (-phase 400V coupling) SINGLE-PHASE AC and SINGLE- PHASE EC motor 4AMA r r r r Flow rate m /h Air stream m Sound pressure db(a) Specifications determined using the following information : Air stream:* with JET+ diffuser for a residual speed of 0. m/s Sound pressure: * measured 8 metres from unit, directivity, attenuation of 6 db 5

7 4AM - Hot Water - SINGLE-PHASE motor and SINGLE- PHASE EC motor 4AM--0* 4AM--5 4AM--5 4AM--5 Air flow rate (m³/h) " " " " " " " " " " " " " " Hc 7, 5,8 4,8,9,9 0, 9,6,5 0,6 9,9 9,8, 9,6 8,4 7, 9,6 8, 6,9 5,8 5,9,9, 0,8,7,8 0,4 9 PD 4,7 6,8,7 8,9 7,9 6,95 6, 5,4 7,4 6,4 5,7 5,07 7,94 6,8 6,04 5, 6,8 5,86 5,8 4,58 7,65 6,5 5,77 5,0 6,4 5,5 4,87 4,4 Hc 0,7 9,4 8,46 7,5 7, 6,9 5,49 4,77 6,87 5,97 5,9 4,6,8, 9,8 8,5,7 0, 9 7,84 5,5,4,9 0,4 4,, 0,8 9,45 PD 8,4 4,6 9,65,7,6,,65,7,46,99,55,4,48,54,77,4,7,,9,8,4,5,9,54, Hc 7,08 6,7 5,49 4,8 6,8 5,95 5,9 4,65,6 9,74 8,5,6 0, 8,96 7,85 5,,,7 0,,8 0,7 9,5 PD 40,4,7 5,7 0, 7,9 9,5 4 9, 4,4,9 5,6 0 5,4 7, 7, 40 0, 4,4 8,9,5 5,6 0,4 5,8 Hc 7,5 6,6 5,94 5,7 7,6 6,8 5,74 5,09,4,8 0,6 9,6,4 0,8 9,7 8,6 6, 4,,8, 4,8,7 0, PD 9, 5,,6 0, 8, 4,4,9 9,5 9, 5,,4 9,87 6,6 0,6 8,48 8,5 4,4,7 9,9 5,5, 9,8 7,8 4AM--40 4AM--40 4AM Hc 7, 5,9 4,9,9 6,8 5,5 4,5,5,9 9,4 7,5 5,7 0,9 8,5 6,7 4,9 40, 6,9 4,6, 8,6 5,5, PD 7,4 6,5 5,55 4,9 6,9 5,96 5, 4,68,9,9 0,5 9,4, 9,9 8,7,,4 0, 8,9, 0,6 9,7 8,6 Hc 0, 8,8 7,78 6,7 9,9 8,58 7,58 6,55 9, 6,9 5, 8,7 6,4 4,5,7 4, 0,9 8,5 6,, 0, 7,8 5,5 PD,99,,85,4,86,,76,6 5,66 4,4,5,76 5, 4,5,,6 5,47 4,,6,6 5,09,9,,45 Hc 0, 8,97 7,98 6,99 0 8,74 7,77 6,8 8,8 6, 4,5,7 8, 5,8 4,,,5 0,4 8, 5,9,6 9,6 7,4 5, PD 8, 9,5,8 8,7 6, 8,,6 7,9 7,4 55,6 44,6 4,8 68 5, 4,8 67,9 5,4 4,,9 6, 48,7 9 0,6 Hc 0,9 9,6 8,6 7,6 0,6 9,5 8,9 7,4 0 7,6 5,8 4 9,4 7, 5,,6 5,, 9,8 7,5 4,, 9 6,8 PD 7,9 4,5 9, 7,,4 8,79,7 6,4,6 7,,7 4,8 0, 6,, 5, 0,5 6,4 9,8, 9 5, 4AM--45 4AM--45 4AM Hc,4,6 0, 9, 9,7 8,5 7, 4,7 8,5 6,,7 7 4, 9,9 54,4 50, 47 4,8 47,8 44 4, 8,5 PD 4,6,7, 0,4 0,7 9,55 8,46,,5 0, 8,96 0,7 9,6 8,4 7,8,5,6 0, 9,0 0,6 9,08 8,04 7,06 Hc 4,,5, 9,9,,5 0, 9,0 5,6,4 0 7,6,77 9,9 7,7 5,5,5 9, 6,,9 9,4 5,6,8 0 PD 6,4 5, 4,,7 5,5 4,4,57,8 5,7 4,47,69,9 4,6,64,95,4 5,69 4,44,57,8 4,47,46,8,8 Hc,7 0,7 9,8,5 0,9 9,7 8,5 4,4, 8,9 6,6,5 8,7 6,7 4,6,6 7,5 4,4,4 7,6 4, 8,7 PD 7,4 56,8 45,9 6,5 6, 48 8,9 0,8 67, 5,7 4,9 5,5 4,, 6, 68,6 5 4,4, 5,5 4 5,7 Hc 4,7,9,6 0,,4,8 0,6 9,4 6, 0,6 8,, 0, 8, 6, 4 9,8 6,8,7 9,7 6,,4 0,8 PD 4,9 7,8 8,6 9,5,6 9,5 5,8,9 5, 0,6 6,6 5,5 0, 6,5,,5 5,4 0,8 6,6 5, 9,9 6,,9 6

8 4AM--50 4AM--50 4AM " " " " " " " " " " " " Hc 8,6 6,9 5, 8,5 6, 4,7, 56, 5,8 48,5 45, 50,9 46,9 4,9 4 74, 68,4 64, 59,8 65,9 60,8 56,9 5, PD 7,9 6,84 6, 5,4 6,8 5,89 5,5 4,65 8,7 7, 6,8 5,5 6,87 5,9 5, 4,6,8 9,74 8,56 0, 8,8 7,8 6,87 Hc 8,6 6, 4,,5 7, 4,8,,4,7 9, 5,8,4 0,5 6,4, 0, 45,8 40, 5,7, 40,7 5,5,7 7,8 PD,9,65,,66,9,7,8,4,7,59,07,59,79,4,7,4 5,46 4,7,44,7 4,9,4,77,7 Hc 8,4 6, 4,,5 6,9 4,7,,5, 8,9 5,7,5 0 6,, 0, 4, 7,5, 9, 8,, 9,5 5,9 PD 40,,4 5,5 0, 4,5 6,9,8 7, 4, 6,6 0,9 5,6 7,, 7, 64,8 49,9 9,9,4 5,6 9,9 5 Hc 9,6 7, 5,5,7 8 5,8 4,,6 5,4, 7,9 4,7 8, 5,, 46, 40,7 6,5,4 4, 6,,4 8,8 PD 9, 5,,6 0, 6,6, 0,9 8,69 0, 5,8,9 0, 6,7, 0,7 8,5 0,7 4, 9,7 5,7 4,5 9, 5,7,6 4AM--6 4AM--6 4AM " " " " " " " " " " " " Hc 45,4 4,9 9, 6,7 4,7 9,4 7 4,5 84, 77,7 7, , 69, 64,9 60, ,5 9,4 85,4 89, 8, 77 7 PD 6,89 5,94 5,8 4,65 6,6 5, 4,7 4,6 4,, 0,7 9,4, 9,74 8,6 7,59,5 8, 6, 4, 5,5,,8 0,4 Hc 6,9, 0,6 7,8 5,,9 9, 6,7 5,4 44,9 40, 5 45,8 40, 5,5, 66, 58, 5, 46, 56 49, 44 8,9 PD,79,4,7,,5,9,5,9 5,8 4,5,67,84 4,69,66,9,9 9, 7,6 5,94 4,76 6,74 5, 4,,4 Hc 7,,7 8,5 5,5, 9,8 7, 49,5 4, 8,,6 44 8, 4, 9,9 / 5, 47, 4,5 5, 44,5 9,7 4,9 PD 6, 8,,7 7,9,4 5, 0, 5,9 7,6 56,5 45, 5, 58,8 45, 6, 8,5 / 8,5 66,5 5, 76,9 59, 47,7 7,6 Hc 8,8 5,,7 0, 7,,8,4 8,9 5,9 46,6 4,8 7, 47, 4,4 7, 65,8 57,9 5, 46, 55, 48,7 4,8 8,9 PD 7,4 8,75 5, 9,77 7,8 4, 7 7,6 7,6,6 7,7 4, 50,9 40,,8 6, 6,8 8,9,8 9 Hc: heating capacity (kw) PD: Water pressure drop (kpa) *: Only available in EC version 7

9 4AM - Chilled water & hot water - SINGLE-PHASE motor and SINGLE-PHASE EC motor 4AM--0* 4AM--5 4AM--40 4AM--45 4AM--50 4AM--6* " " " " " " " " " " " " Hc 7, 5,8 4,8,9,4 9,7 8,5 7, 8,9 6,6 4,9, 40,6 7,4 5,,8 54,9 50,6 47,4 44, 8 75,7 7 66,4 PD 4,7 6,8,7 8,9 5, 4,5 4,5 7, 6, 5,5 4,8 7,8 6,7 6 5, 7, 6, 5,6 4,9,,4 0, 8,9 Hc 0,7 9,4 8,46 7,5,8, 9,8 8,6 7, 5,,7 5,9 9,5 7,,9 9,6 6,4, 5,6 45,4 40,6 5,9 PD 8,4 4,6 9,65,,6,,,9,5,,6,,7,,4,6 5,8 4,6,7 Hc,5 0,9 9,7 8,5 6,8 4,6,4,5 0,5 8, 6,7 7,6 4,6,6 46 4, 6,6, PD 7,6, 6,9, 6,6 8,4,7 7,8 9,4 0,6 4,5 9, 6,5 8,,8 7,9 44,9 5, 4,,4 4AM--0* 4AM--5 4AM--40 4AM--45 4AM--50 4AM--6* Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% Relative humidity 50% Air flow rate (m³/h) " " " " " " " " " " " " Tcc,95,65 4,59,8 4,8 5,6 4,6 5,9 7,64 7, 8,87,6 9,66, 5,7 5, 9, 4,4 7- Scc,95,5,99,8 4,8 5,7 4,6 5,85 6,98 7, 8,67 0, 9,66,8,7 5, 8, 0,8 PD 4,4 6, 55,4,69 6,,46 5,55 9,08 4,44 6,75, 4, 6,55 0,7 8,46, 0,6 8-,69,8 4,06,96,9 4,9 4,04 5, 6,7 6,9 8,08 0, 8,66 0,9,9,8 7,,7 8- Scc,69,4,75,96,9 4,78 4,04 5, 6,46 6,9 8,0 9,47 8,66 0,9,9,8 6,8 9,6 PD 0,4 9,5 4,8,8, 4,86,68 4,5 7,06,6 5,65 8,76,4 5,7 8,5 6,98 0,6 6,5 Tcc,5,7,,6,,99,9 4, 5,4 4,84 6,54 8,9 6,55 8,86, 0,8 4 7, 0-5 Scc,5,7,6,6,,99,9 4, 5,4 4,84 6,54 8, 6,55 8,86 0,8 4 6,9 PD,4 0,6 9,7 0,99,98,,4,9 4,74,,75 5,79,0,57 5,5 4,8 7, 0,7 Hc: Heating capacity (kw) TCC: total cooling capacity SCC: sensible cooling capacity (kw) PD: Water pressure drop (kpa) *: Only available in HEE version 8

10 4AM - Hot Water - Three-phase motor 4AM--5 4AM--5 4AM Hc,9 0, 9,6, 0, 9,69 9,05,7 0 8,7 7,4 9,7 8, 7 5,9 6,6 4,5,9,4,7,8 0,4 9 PD 7,9 6,86 6, 5,4 7,09 6,4 5,48 4,84 8,9 7,04 6, 5,48 6,86 5,89 5, 4,6 8,04 6,86 6,07 5, 6,4 5,49 4,86 4,4 Hc 7, 6, 5,5 4,78 6,7 5,8 5,7 4,49, 9,98 8,67,8 0, 9,04 7,87 5,9,8, 0,7 4,, 0,8 9,47 PD,8,6,,66,0,6,9,48,5,57,06,59,79,5,7,4,5,4,9,5,5,9,55, Hc 7,08 6,8 5,5 4,8 6,66 5,8 5,6 4,5,8, 9,9 8,69,6 0, 9 7,88 5,6,6, 0,6,8 0,7 9,6 PD 40,5,7 5,7 0, 6, 8,,9 8, 4,8 6,8 0,7 5,6 7,5, 7, 4,4 5,7 0,5 5,6 0,4 5,8 Hc 7,5 6,6 5,95 5,8 7,08 6, 5,59 4,96,7 0,8 9,5,4 0,9 9,77 8,66 6,7 4,7,,6 4,8,7 0, PD 9, 5,,7 0, 7,,7, 9, 0 5,7,8 0, 6,7, 0,7 8,55 9,5 5,, 9,79 5,5, 9,8 7,8 4AM--40 4AM--40 4AM Hc 6,9 5,6 4,6,6 6, 4,8,9,9 9,4 7,5 5,7 9,9 7,5 5,8 4, 9,8 6,6 4, 6,8,8,7 9,5 PD 7,0 6,04 5,7 4,74 6,8 5,5 4,9 4,,9,9 0,5 9,4, 0,5 9, 8,8,, 9,9 8,76, 9,69 8,6 7,55 Hc 0 8,65 7,64 6,6 9,5 8, 7,6 6,9 9, 6,9 5, 8, 5,8 4,, 4 0,8 8,4 6, 9, 7 4,8 PD,9,,79,7,65,0,6,7 5,66 4,4,5,76 4,99,9,,45 5,9 4,6,,59 4,66,58,88,6 Hc 0, 8,8 7,8 6,86 9,6 8,7 7,44 6,5 8,8 6, 4,5,7 7,6 5,,6,9, 0, 8 5,8,5 8,7 6,6 4,6 PD 6,8 8,5 8,,5 6 6,4 7,4 55,6 44,6 4,8 6,6 49, 9,4 0,8 66,9 5,6 4,6,4 57,6 44,5 5,7 8 Hc 0,7 9,4 8,45 7,48 0, 8,96 8,0 7, 0 7,6 5,8 4 8,8 6,5 4,8, 5,9 9,6 7,4, 0, 8, 6, PD 7,,6, 8,9 5,7,4 0, 8,,7 6,4,6 7, 9,8, 9, 5,,6 4,7 0, 6, 7,4, 7,4,9 4AM--45 4AM--45 4AM Hc,7,9 0,6 9, 9,4 8, 7 44, 40,8 8, 5,7 9, 6,,9,7 57,4 5,9 49,6 46, 49,8 45,9 4 40, PD 4,9,6 0, 0,4 9,4 8,9 4,8,7, 9,96,9 0, 9,08 8,0 5,8, 9,97,5 9,84 8,7 7,65 Hc 4,5,7,4 0,,8, 0, 8,84 7,7, 8,7 4,, 8,8 6,5 5, 0,9 7,5 4, 0,7 6,8,9 0,9 PD 6,58 5,4 4,,45 5, 4,,46,74 6, 4,99 4,08,7 5, 4,04,,6 6,7 4,89,95, 4,84,76,0,7 Hc,9, 0,8 9,5, 0,7 9,54 8,8 5,8,5 0 7,5,9 9,9 7,7 5,5,4 9 5,8,6 8,9 5,, 9,6 PD 74, 58, 47, 7,4 59, 46,4 7,7 9,9 74,7 57,9 46,6 6,6 59,8 46, 7, 9, 76,5 58,7 47 6,7 58, 44,7 5,9 8 Hc 4,9,,8 0,5,,6 0,4 9,5 7,7 4,,9 9,4 4,5,6 9,4 7, 5,8,5 8, 5,, 7, 4,5,7 PD 5,7 8,5,6 9, 8,6,8 8,8 5, 5,4 8, 8,5 8,4,5 8,4 4,9 5,9 8, 8, 7,4,6 7,6 4 9

11 4AM--50 4AM--50 4AM Hc,7 9, 7,4 5,6 8,6 6,4 4,8, 57,4 5,9 49,5 46, , 76,4 70,4 65,9 6,6 65,7 60,6 56,7 5 PD 8, 7, 6, 5,6 6,84 5,9 5,9 4,68 8,6 7,8 6,54 5,74 6,9 5,9 5,5 4,65,5,6 0, 9,0 0, 8,76 7,6 6,8 Hc 9 6,5 4,6,7 7, 4,9,,5 4,4 9,8 6,4,9 0,6 6,5,4 0, 47, 4, 6,8, 40,6 5,5,6 7,7 PD,5,75,,7,94,8,84,4,5,69,5,65,8,6,7, 5,75 4,49,67,86 4,7,4,76,6 Hc 8,8 6,4 4,6,8 7 4,8,,6,9 9,5 6, 0, 6,, 0,4 44,4 8,6 4, 0, 8,, 9,5 5,8 PD 4,9,6 6,4 0,9 4,8 7, 7,5 44,8 4,5 7,7,7 5,8 7,5, 7, 68,5 5,7 4,, 5, 9,7,8 4,9 Hc 0 7,6 5,8 4 8, 5,9 4,,7 6,,7 8,5 5,, 8, 5,,4 47,7 4,9 7,6,4 4 6, 8,7 PD 9,9 5,8 0,5 6,7, 0,9 8,77 6,4,5 0,7 6,8, 0,7 8,57,4 5,4 0,8 6,6 4,4 9, 5,7,5 4AM--6 4AM--6 4AM Hc 46,5 4,9 40, 7,5 44, 40,7 8, 5,6 87,9 8 75,9 70,9 80,8 74,5 69,8 65, ,6 00 9, 86,5 80,8 PD 7,9 6, 5,5 4,85 6,5 5,6 4,99 4,4 5,,,6 0,, 9,9 8,7 4 0,5 8, 6 9, 6,5 4,6,9 Hc 7,6,9 8, 6,,6 9,9 7, 5,5 46,8 4,8 6,5 49, 4, 8,,5 70 6,7 55,4 49, 6,7 55, 49,5 4,7 PD,9,4,78,8,64,0,6,5 6,7 4,88,96,07 5,7 4,9,6,6 0, 8, 6,6 5, 8,6 6,56,7 4,6 Hc 7,8 4,,5 8,9 6,,9 0,4 7,9 5, , 47,4 4, 6,8, / 56,4 50, 44, 57,6 50, 44,6 9, PD 7,9 9,4,7 8,6 4, 6,6,5 6,9 79,8 6, 49, 8,4 67,9 5, 4,9,8 / 9,9 74,5 58, 96,6 74, 59,5 46,7 Hc 5,7 5,9, 0,6 6,4 4,6 9,5, 48,6 4,6 8,7 4,5 44,6 40, 5,6 9,9 6,5 55, 49,,6 54,7 49, 4,8 PD 7,7,9,5 9, 6,6 0, 8,6 7 9,,8 9,6 4,8 0, 6, 56,9 44,8 6,8 9,4 45,6 6, 9,5,8 Hc: Heating capacity (kw) PD: Water pressure drop (kpa) 0

12 Electric motor specifications Use Family Size Motor HEATING HEATING COOL- ING HEATING COOL- ING THREE-PHASE 0/400 V - 50 Hz SINGLE-PHASE 0 V- 50 Hz Rotation speed rpm I. Name A Max. abs. P W IP Thermal cut-out Class Operating temp. 4AM-- 5H -ê 85 0, C / +60 C ,5 70 4AM--/ 4AMA- - ê 404 0, H/ , 70 - ê 85, 550 4AM--/ 4AMA- 45H/ ,64 80 YES F - ê 9, A - 65 C -40 C / +70 C 4AM--/ 4AMA- 50H/ ,9 50 4AM--/ 4AMA- 6H/6- - ê 000, ,6 50 4AMS- 6H - ê 000, ,6 50 4AM-- 5H 0 0, C / +60 C 4AM--/4AMA- 40H/40-400, 00 YES 4AM--/4AMA- 45H/45-80,0 480 F A - 65 C -40 C / +70 C 4AM--/4AMA- 50H/50-40, AM--/4AMA- 6H/6-9, AM-- 5C 880 0, C/+60 C 4AM-- 40C 890 0,5 0 YES F 4AM-- 45C 9 0, A - 65 C 40 C/+70 C 4AM-- 50C AM-- 6C EC FMA 4AM-- 0H 50 0, PTC B -5 C/+60 C 4AM-- 5H 480, PTC B -5 C/+60 C 4AM--/4AMA- 40H/40-760, Thermal cut-out B -5 C/+60 C 4AM--/4AMA- 45H/45-500, Thermal cut-out B -5 C/+60 C 4AM--/4AMA- 50H/50-440, Thermal cut-out B -40 C/+60 C 4AM--/4AMA- 6H/6-00, Thermal cut-out B -40 C/+60 C SINGLE-PHASE 0 V 50/60 Hz 4AM-- 0C 50 0, PTC B -5 C/+60 C 4AM-- 5C 040 0, PTC B -5 C/+60 C 4AM-- 40C 760, Thermal cut-out B -5 C/+60 C 4AM-- 45C 500, Thermal cut-out B -5 C/+60 C 4AM-- 50C 970, Thermal cut-out B -5 C/+60 C 4AM-- 6C 770, Thermal cut-out B -5 C/+60 C Coil specifications WATER COIL Number of heating rows Number of cooling rows Coil capacity (L) 0,8 0,68,8,66 0,96,59,8,8,7,,8,8 4,55,97 4,7 6,4 Connection diameter / ¾" " ¼ Connection type Threaded unions 4 GCU F/M Maximum operating pressure 8 bar Test pressure 6 bar Max T 0 C

13 Dimensions 4AM air heater Size A B C D Weight (kg) STD EC mm row rows rows S AMA Destratifier Size A B C X Y STD EC Weight kg Ceiling 4AM air heater 4AMA Destratifier Wall-mounted installation Ceilingmounted installation

14 Assembly accessories A different assembly for each use. RETURN AIR MODULE Size A B C Codes /6S Size A B C Codes Filter box (G filter in accordance with EN 779) Prevents premature clogging of exchanger coils Not ductable -channel mixing box with built-in filter Adjusts the supply of fresh air to levels required by current regulations and mixes it with return air. Built-in G filter and connecting flange for cubic ducts. Air access sides configurable on-site. For compliance with standard ERP 06, the air heater can only operate with a maximum of 0% fresh air. DIFFUSION MODULE Size A B C Codes /6S Size A B C Codes /6S Diffuser on door Create an air curtain that limits energy loss when doors are opened. Diffuser for large spaces Reduction cone for increasing the air throws. ASSEMBLY SUPPORT ACCESSORIES Size Codes Wall bracket All to Additional kit for fastening on an IPN 50 to 6/6S 780 Size Codes All 786 Suspension support for ceiling mounting DUCT ACCESSORIES Size A B C Codes Antifreeze damper

15 Electrical accessories ELECTRICAL & USER SAFETY Codes Padlockable proximity switch Available in a or -speed version, this accessory must be placed at least metres from any rotating part, to comply with French standard IT 46, Art. 4-7-, and EC requirements. Use Circuit breaker unit - FMA -PH heating Circuit breaker unit - HEE FMA -PH heating Circuit breaker unit - FMA -PH cooling Circuit breaker unit - HEE FMA -PH cooling Circuit breaker unit - -PH 4AM AM AM AM AM AM AMS AMA AMA AMA AMA THERMOSTATS Codes TC-EC0 TA-AC0 Codes Manual/auto room thermostat SINGLE-PHASE installation -speed EC thermostat kit (for EC SINGLE-PHASE FMA) - Heating and cooling with manual toggle switch - Inductive breaking capacity.5a -speed AC thermostat kit (for AC SINGLE-PHASE FMA) Heating and cooling with manual toggle switch - Inductive breaking capacity.5a IP54 industrial environment thermostat THREE-PHASE installation 75: stage 76: stages SUPPLY AIR SPEED SELECTION Codes / switch For -phase motor, selects two motor rotation speeds and stop. Codes Autotransformer with selector switch (.5 A) Adjusts the voltage on single-phase motors with one variable speed to achieve up to five supply air speeds

16 4AM single-phase EC air heater control HEE MONO BOX range, controls six 4AM-- air heaters or three 4AM-- air heaters + three 4AM-- FMA 0-0V control FMA FMA Supply 0 V /50 Hz VALVE 4 Vac power supply VALVE 0-0V control Description 0 V/50 Hz mains supply - Complete "PLUG & PLAY" control solution for air-source (0-0 V -PH EC FMA) and/or water-source (0-0 V threeway valve) for 4AM air heaters equipped with SINGLE-PHASE EC FMAs. - Proportional control system adjusts the supply air rates and coil water supply based on the difference between the indoor temperature (measured by the built-in sensor) and the programmed temperature setpoint (summer or winter). - Built-in timer featuring operating modes: COMFORT, ECO and FROST PROTECTION (weekly setting). - Electrical components (circuit breaker, padlockable proximity switch, contactor, thermostat, timer, etc.) included. Remote control On/Off function, with two fault summaries. Communication possible via ModBus/JBUS protocols or BACnet IP (optional expansion card). Advantages - All your air heaters will be controlled centrally via an EC MONO BOX master controller box - You can adjust the heating or cooling to meet your needs as water is supplied to one or more heat exchangers in proportion to your building's heat requirements (available with the optional valve kit). - Supply air temperatures are controlled to maintain the necessary air streams. You can choose between fresh air only or mix with frost protection via the actuator to be installed on the -channel mixing box with built-in filter (available with the fresh air kit + damper actuator + frost protection thermostat kit) or 00% recirculated air. - You will bring the fresh air rate of your building in line with current regulations or according to the space occupancy (via the built-in timer) thanks to an internal timer which can be configured on a weekly basis using operating modes (Comfort, Eco, Frost protection). Fresh air damper controlled via the EC MONO BOX (On/off) depending on optional fresh air kit (Antifreeze thermostat + servomotor). - A building's heat gain will depend on its occupancy, using centralised management of the 4AM air heaters via the controller (one EC MONO BOX controls six 4AM- heaters or six 4AMA- heaters or three 4AM- heaters + three 4AMA- heaters). - The display shows the operating status of each individual 4AM heater (fresh air or return air, motor fault, risk of frost, etc.) - No need to size and wire the electrical components (circuit breaker, padlockable proximity switch, contactor, thermostat, timer, etc.) as this all-in-one control solution makes for faster installation:. - Two user levels: USER (restricted access) and INSTALLER (full access) for greater simplicity, ease of use and security. - Option to use a remote control On/Off function with two fault summaries. Communication possible via ModBus/JBUS protocols or BACnet IP (optional expansion card). Electrical specifications - HEE MONO BOX unit supply: 0 V single-phase - Protection rating: IP54 - Built-in motor overload and user protections as required by French standard NF C

17 Quality and Environment Management Systems Approval Order No.: 0040, Supersedes order No.: 0040, 0.05 The manufacturer reserves the right to change any product specifications without notice. Manufactured for Carrier in France. Printed in the European Union.

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation The most competitively priced technical solution for heating large spaces New H400 model New HEE control Ensures buildings warm up ultra fast Excellent diffusion via patented JET+ double deflection technology

More information

New HEE control. nroom thermostat for THREE-PHASE or SINGLE-PHASE installation

New HEE control. nroom thermostat for THREE-PHASE or SINGLE-PHASE installation New H400 model New HEE control The most competitively priced technical solution for heating large spaces Ensures buildings warm up ultra fast Excellent diffusion via patented JET+ double deflection technology

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

CLIMACIAT AIR COMPACT

CLIMACIAT AIR COMPACT Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw. Slim design and acoustic comfort Saves up to 40% floor space Capacity up to 50 kw Free cooling Water misting Use Drycoolers in this range are mainly designed for cooling water or glycol/water mix for:

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Halton Rex for Vario R6O - Variable air volume chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

Energy-efficient heat source provides comfort in large rooms

Energy-efficient heat source provides comfort in large rooms AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating

More information

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Optimal work climate with open doors. Industrial air curtains Model IndAC

Optimal work climate with open doors. Industrial air curtains Model IndAC Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain Air curtains 114 MRX condensing gas air curtain 118 MRA-H gas air curtain 121 MRA-A ventilation only air curtain 122 SW / SE hot water / electrical air curtain 124 SWR / SER built-in hot water / electrical

More information

CAW Ceiling-mounted fan heaters for hot water

CAW Ceiling-mounted fan heaters for hot water Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot ceiling-mounted fans are used for heating entrances, warehouses, industrial premises, workshops,

More information

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h KOG LN Low Noise Chilled Water Cassettes 09, 12 & 18 1.70 to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

NEW RANGE OF WARM AIR CURTAINS

NEW RANGE OF WARM AIR CURTAINS NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible

More information

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Cassette units Model Comfort Circle. - heating - cooling - ventilation Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their

More information

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL

More information

Fan heater SWT Ceiling mounted fan heater with water heat

Fan heater SWT Ceiling mounted fan heater with water heat Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and

More information

Ceiling diffusers. Type DLQL

Ceiling diffusers. Type DLQL X X testregistrierung Type Horizontal one-way air discharge Horizontal two-way air discharge Horizontal four-way air discharge Horizontal duct connection For horizontal one-way to four-way air discharge,

More information

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam Halton CBH Active Chilled Beam Combined cooling, heating and supply air unit for exposed wall installation Well suited for hotel guest rooms with high requirements for thermal comfort and room acoustics

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

KPSW CONSOLE TERMINAL UNIT

KPSW CONSOLE TERMINAL UNIT TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0 MARKING This product marked conforms to the essential

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more

More information

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling MORE n More efficient n More flexible n More intelligent for LESS n Less energy n Less time n Less noise Capacity: up to 1100 kw 410A 407C 134a 404A Free cooling Water misting Use The range, available

More information

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

TERM-E ELECTRIC HEATING AND VENTILATION UNITS ELECTRIC HEATING AND VENTILATION UNITS INTENDED USE The heating units with axial fans, metal casing and electric heaters are designed to heat rooms such as: industrial halls, workshops, warehouses, commercial

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications air HanDLIng UnIT: CLIMaCIaT represents the

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better A guide to choosing The group It s 1961 and Galletti with its Jolly copper

More information

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers : SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING Low Water-Temperature system wall and ceiling mounting 2-or 4-Pipe system heating and /or cooling with or without casing easy installation EC motor silent, powerful, economical, sustainable 2-PIPE 4-PIPE

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

LOWERING THE COST OF HIGH CEILINGS

LOWERING THE COST OF HIGH CEILINGS LOWERING THE COST OF HIGH CEILINGS in partnership with The Carbon Trust recommends destratification as an effective energy-saving strategy.* WHY CHOOSE ZOO FANS? Fast Payback ZOO Fans create even temperatures

More information

INDUSTRIAL AIR CURTAIN. IndAC 2

INDUSTRIAL AIR CURTAIN. IndAC 2 INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F

More information

QZB "Standard" comfort fan coil

QZB Standard comfort fan coil Key features Vertical or horizontal installation Concealed installation or with decorative cabinet Cooling ( pipes) and heating ( pipes or electrical heating) ECM version for low energy consumption The

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Units for suspended cei lings

Units for suspended cei lings . X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Precision air handling cabinets Ciatronic MICRO/EXPAIR / Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545 NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

Vertical self-contained air conditioner

Vertical self-contained air conditioner Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

ATC Heating Devices. P. 1 ATC Heating Devices

ATC Heating Devices. P. 1 ATC Heating Devices ATC Heating Devices P. 1 ATC Heating Devices ATC Heating Devices Suspended water heater FWW The hot water heater is attached to a wall using brackets. The direction of air flow (upwards or downwards) is

More information

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw. Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

Halton CHB Active chilled beam with boost function for bulkhead installation

Halton CHB Active chilled beam with boost function for bulkhead installation Halton CHB Active chilled beam with boost function for bulkhead installation Combined cooling, heating, and supply-air unit for bulkhead installation Different sizes, to meet various cooling and air-flow

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

PREEVA air handling unit

PREEVA air handling unit APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu

More information