OPERATING MAX FUSE WEIGHT (LBS.) MCA HP FLA RLA LRA COOLING DATA GAS HEATING SECTION ELECTRICAL DATA INPUT SC (MBH) LAT EAT TC (MBH) OUTPUT (MBH)

Size: px
Start display at page:

Download "OPERATING MAX FUSE WEIGHT (LBS.) MCA HP FLA RLA LRA COOLING DATA GAS HEATING SECTION ELECTRICAL DATA INPUT SC (MBH) LAT EAT TC (MBH) OUTPUT (MBH)"

Transcription

1 NEW WTER - SOURCE HET PUMP SCHEDULE TG NO. MKE MODEL RISER SIZE FN DT COOLING 80/65 HETING DT ELECTRICL DT WTER COND. ESP SPD (20% P.G.) GPM ECH* EWT/LWT TC SC EWT HC VOLTS PH FN COMPRESSOR HP FL RL LR 200 WHLEN VI " / UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL 300 WHLEN VI " / UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL MC MX FUSE OPERTING WEIGHT (LBS.) REMRKS 400 WHLEN VI " / UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL 600 WHLEN VI " / UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL FN SCHEDULE TG NO. BSIS OF SELECTION SERVICE TYPE ESP (in. w.c.) FN DT MOTOR DT RPM BHP MC CLSS DRIVE TYPE FL RPM VOLTS PH REMRKS KEY PLN EF- BRON MODEL 671 TOILET EXHUST CEILING BLOWER I DIRECT ODP BDD, ISOLTORS, INTERLOCKED W/ LIGHTSWITCH. EF-B BRON MODEL 684 TOILET EXHUST CEILING BLOWER , W I DIRECT ODP 0.5 1, BDD, ISOLTORS, INTERLOCKED W/ LIGHTSWITCH. EF-C BRON MODEL 684 JNITOR'S CLOSET CEILING BLOWER , W I DIRECT ODP 0.5 1, BDD, ISOLTORS, RUNS CONTINUOUSLY. ROOFTOP UNIT SCHEDULE SUPPLY FN DT COOLING DT GS HETING SECTION ELECTRICL DT TG NO. BSIS OF SELECTION SERVICE ESP (in. w.c.) BHP HP MOTOR TYPE MODULTION MIN. O.. TC SC MB. (F) EDB/EWB LDB/LWB # OF STGES REFRIG. TYPE GS IGNITION FUEL ET LT INPUT OUTPUT STGES QTY. COMPRESSOR RL (ea.) LR (ea.) CONDENSER # OF FNS HP (ea.) MC MOCP VOLT PH OPER. WEIGHT (LBS.) REMRKS RTU-6 TRNE YHC-060 NOM. 5 TONS NEW DDITION PUBLIC SPCES 2, " PREM. EFF. NONE 400 2, /64 55/54 ONE R-410 ELECTRONIC PROPNE ONE NOTES 1, 2, 3, 4, 5, 6, 7, 8, 9 NOTES: 1. MERV 8 FILTERS 2. COMPRTIVE ENTHLPY ECONOMIZER W/ HOOD 3. CONVENIENCE OUTLET 4. 7 DY PROGRMMBLE THERMOSTT. 5. FULL CPCITY POWER EXHUST 6. 5-YER COMPRESSOR WRRNTY 7. LOW MBIENT CONTROLS 8. ROOF CURB 9. CONTROLS TO LOCK-OUT COOLING SYSTEM DURING EMERGENCY GENERTOR HETING OPERTION. PUMP SCHEDULE TG NO. SERVICE STTUS MKE & MODEL TYPE GPM PERFORMNCE DT HED (ft.) RPM HP FLUID V/PH/HZ ELECTRICL DT MOTOR TYPE REMRKS P-1, 2 HETING HOT WTER EXISTING TCO VI-2006 VERTICL IN-LINE /4 20% PG 208/3/60 PREM. EFF. BRONZE FITTED, GUGE TPS, 170# WP, NOL. P-3, 4 CONDENSER WTER EXISTING TCO FE-2010 FRME MOUNTED % PG 208/3/60 PREM. EFF. BRONZE FITTED, GUGE TPS, 170# WP, SUCTION DIFFUSERS, NOL. P-3, 4 CONDENSER WTER NEW TCO FI-2510C FRME MOUNTED % PG 208/3/60 PREM. EFF. INV. DUTY VFDS, GUGE TPS, 175# WP, SUCTION DIFFUSERS. EXIST. COOLING TOWER SCHEDULE (FOR REFERENCE ONLY) TG NO. BSIS OF SELECTION TYPE CT-1 EVPCO LRW LOW PROFILE/CLOSED CIRCUIT COOLER NO. FNS 18, /2 BELT FN DT HP DRIVE MOTOR VOLTS PH HZ PREMIUM EFF. INVERTED DUTY THR EWT/LW T COOLING DT MBIENT LWT GPM / FLUID 20% PROP. GLYCOL OPERTING WEIGHT (LBS.) 6,890 CCESSORIES DISCHRGE HOOD W/ DMPER & MOTOR, FLOT VLVE, PREM. EFF. SUMP PUMP MOTOR (1 HP), ELECTRIC SUMP HETER (3 kw), VFD (BB, OR EQUL) W/ UTOMTIC BY-PSS, STINLESS STEEL BSIN ND 5-YER MOTOR & DRIVE WRRNTY. HVC DRWING LIST M-1 HVC SCHEDULES & LEGEND M-2 PRTIL FIRST FLOOR HVC PLN - DEMOLITION C CCU CD CV D FF HU TC BB BDD BHP BLDG BOD BSMT BTU CD CHWR CHWS CLG CO CONC CONN CONTR CWR CWS D DDC DB DIFF DN DX E ET EBH EFF EF EG EHC EL EXIST. WTER - SOURCE HET PUMP SCHEDULE (FOR REFERENCE ONLY) TG NO. MKE MODEL HVC LEGEND & BBREVITIONS IR CONDITIONING UNIT IR COOLED CONDENSING UNIT UTOMTIC CONTROL DMPER UTOMTIC CONTROL VLVE CCESS DOOR BOVE FINISHED FLOOR IR HNDLING UNIT UTOMTIC TEMPERTURE CONTROL BSEBORD BCKDRFT DMPER BRKE HORSEPOWER BUILDING BOTTOM OF DUCT BSEMENT BRITISH THERML UNITS CEILING DIFFUSER CUBIC FEET PER MINUTE CHILLED WTER RETURN CHILLED WTER SUPPLY CEILING CLEN OUT CONCRETE CONNECTION CONTRCTOR CONDENSER WTER RETURN CONDENSER WTER SUPPLY DRIN DIRECT DIGITL CONTROL DRY BULB DIFFUSER DOWN DIRECT EXPNSION ECH ENTERING IR TEMPERTURE ELECTRIC BSEBORD HETER EFFICIENCY EXHUST FN EXHUST GRILLE ELECTRIC HETING COIL ELEVTION RISER SIZE FN DT COOLING 80/65 HETING DT ELECTRICL DT WTER COND. ESP SPD ELEC ELECTRICL ER EXHUST REGISTER ESP EXTERNL STTIC PRESSURE EUH ELECTRIC UNIT HETER EWH ELECTRIC WLL HETER EWT ENTERING WTER TEMPERTURE EXH EXHUST EXP EXPNSION FI FRESH IR INTKE FCU FN COIL UNIT FD FIRE DMPER FL FULL LOD MPS FLEX FLEXIBLE F DEGREES FHRENHEIT F & TT FLOT & THERMOSTTIC TRP FPM FEET PER MINUTE FTR FINNED TUBE RDITION G GUGE GC GENERL CONTRCTOR GPM GLLONS PER MINUTE HC HETING COIL HCR DUL TEMPERTURE WTER RETURN HCS DUL TEMPERTURE WTER SUPPLY HP HORSEPOWER HVC HETING, VENTILTION, & IR CONDITIONING HW HOT WTER HWR HOT WTER RETURN HWS HOT WTER SUPPLY HZ HERTZ IN NCHES KW KILOWTT LT LEVING IR TEMPERTURE LF LINER FEET LR LOCKED ROTOR MPS LWT LEVING WTER TEMPERTURE MECH MECHNICL MEZZ MEZZNINE MIN MINIMUM MTD MOUNTED N/ NOT PPLICBLE (20% P.G.) GPM ECH* NC NORMLLY CLOSED NIC NOT IN CONTRCT NO NORMLLY OPEN NO. NUMBER NTS NOT TO SCLE O OUTSIDE IR OI OUTSIDE IR INTKE PC PUMPED CONDENSTE PD PRESSURE DROP PHC PREHET COIL PLBG PLUMBING PRV PRESSURE REGULTING VLVE PSIG POUNDS PER SQURE INCH G. R RETURN IR RET RETURN REQ'D REQUIRED RG RETURN GRILLE RH RELTIVE HUMIDITY RHC REHET COIL RPM REVOLUTIONS PER MINUTE RR RETURN REGISTER S SUPPLY IR SD SMOKE DMPER SF SUPPLY FN SG SUPPLY GRILLE SR SUPPLY REGISTER T THERMOSTT TD TRNSFER DUCT TG TRNSFER GRILLE TYP. TYPICL UD UNDERCUT DOOR UH UNIT HETER V VENT VV VRIBLE IR VOLUME VD VOLUME DMPER VFD VRIBLE FREQUENCY DRIVE W WIDTH W/ WITH WB WET BULB TEMPERTURE EWT/LWT NOTE: LL ITEMS SHOWN RE NOT NECESSRILY USED ON THIS PROJECT 1 T H SD CO2 EF # RTU # WSHP # EBH _'-0" CONNECT TO EXISTING LIMIT OF DEMOLITION REVISION NUMBER TEMPERTURE SENSOR OR THERMOSTT HUMIDITY SENSOR OR HUMIDISTT SMOKE DETECTOR CO2 DETECTOR EXHUST FN ROOFTOP UNIT TC ELECTRIC BSEBORD HET SC EWT HC VOLTS DUCTWORK LEGEND LINER SLOT DIFFUSER (ONE SLOT) 4'-0" L (UNLESS OTHERWISE NOTED) DOUBLE SLOT DIFFUSER (TWO SLOT) 4'-0" L (UNLESS OTHERWISE NOTED) NEW CEILING DIFFUSER (CD) EXISTING CEILING DIFFUSER (CD) NEW RETURN GRILLE (RG) (24"x24", UNLESS OTHERWISE NOTED) EXISTING RETURN GRILLE (RG) EXHUST REGISTER (ER) EXISTING DUCTWORK EXISTING DUCTWORK TO BE REMOVED NEW DUCTWORK UNDERCUT DOOR RETURN OR EXHUST IR FLOW SUPPLY IR FLOW TRNSFER GRILLE PH FN SINGLE LINE OR COMPRESSOR HP FL RL LR 300 WHLEN VI "Ø 7/8" OD 340 0" / F UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL 400 WHLEN VI /4"Ø 7/8" OD 414 0" / F UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL 600 WHLEN VI /4"Ø 7/8" OD 630 0" / F UNIT MOUNTED THERMOSTT & FLUSH MTD. COUSTICL R.. PNEL * - CTUL RISER GPM IS SUM OF LL GPM (ECH) OF FCUs ON THE GIVEN RISER. W EWH _ kw WTER-SOURCE HET PUMP ELECTRIC WLL HETER SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN / EXHUST DUCT UP RETURN / EXHUST DUCT DOWN STNDRD RDIUS ELBOW (R = W) SPLIT TKE-OFF W/ BRNCH DMPERS SUPPLY BULLHED SPLIT SUPPLY CEILING DUCT MTD. DIFF / GRILLE COUSTICLLY LINED DUCT MC DOUBLE LINE w OR R MX FUSE SINGLE LINE RISE UP OPERTING WEIGHT (LBS.) DROP DN VD VD CD BDD FD RISE OR DROP BULLHED CONVERGE FLEXIBLE DUCT (MX. 48"L) CEILING DUCT MTD. DIFF / GRILLE VOLUME DMPER UTOMTIC CONTROL DMPER (CD) BCKDRFT DMPER FIRE DMPER DOUBLE LINE RISE UP DROP DN VD VD CD BDD FD PIPING LEGEND D CHWS CHWR CWS CWR HCS HCR HWS HWR LPS LPCR FOS FOR REMRKS PIPE BREK (SINGLE LINE) DRIN CHILLED WTER SUPPLY CHILLED WTER SUPPLY CONDENSER WTER SUPPLY CONDENSER WTER RETURN DUL TEMPERTURE WTER SUPPLY DUL TEMPERTURE WTER RETURN HOT WTER SUPPLY HOT WTER RETURN LOW PRESSURE STEM LOW PRESSURE CONDENSTE RETURN FUEL OIL SUPPLY FUEL OIL RETURN RELIEF VLVE UTO. IR VENT DRIP LEG FLEXIBLE CONNECTION INCRESER OR DECRESER CONCENTRIC ELBOW UP OR RISE ELBOW DN OR DROP CIRCUIT SETTER CONTROL VLVE (2-WY) END CP CLEN-OUT FOR CONDENSTE DRIN GTE VLVE BUTTERFLY VLVE GLOBE VLVE BLL VLVE CHECK VLVE STRINER W/DRIN VLVE & HOSE CONN. UNION CONTROL VLVE (3-WY) LIQUID FILLED PRESSURE GUGE w/ BLL VLVE PIGTIL FOR STEM, & SCRUBBERS FOR WTER. SWIVEL BSE WELL TYPE 10" THERMOMETER DIRECTION OF FLOW IN PIPE BLIND FLNGE M-3 PRTIL SECOND FLOOR HVC PLN - DEMOLITION M-4 PRTIL ROOF LEVEL HVC PLN - DEMOLITION M-5 PRTIL FIRST FLOOR HVC PLN - NEW WORK M-6 PRTIL SECOND FLOOR HVC PLN - NEW WORK M-7 PRTIL ROOF LEVEL HVC PLN - NEW WORK M-8 HVC DETILS CONTROLS LEGEND I O DI DO FI DDC FMS DP DPV CV CD SP NLOG INPUT NLOG OUTPUT DIGITL INTPUT DIGITL OUTPUT FULL INTEGRTION DIRECT DIGITL CONTROLS FLOW MESURING STTION DIFFERENTIL PRESSURE DIFFERENTIL PRESSURE VLVE UTOMTIC CONTROL VLVE UTOMTIC CONTROL DMPER STTIC PRESSURE

2 KEY PLN M-2 PRTIL FIRST FLOOR HVC PLN - DEMOLITION B M-2 PRTIL FIRST FLOOR HVC PLN - DEMOLITION

3 KEY PLN M-3 PRTIL SECOND FLOOR HVC PLN - DEMOLITION

4 KEY PLN M-4 PRTIL ROOF LEVEL HVC PLN - DEMOLITION

5 KEY PLN PRTIL FIRST FLOOR HVC PLN - NEW WORK B PRTIL FIRST FLOOR HVC PLN - NEW WORK M-5 M-5

6 KEY PLN M-6 PRTIL SECOND FLOOR HVC PLN - NEW WORK

7 KEY PLN M-7 PRTIL ROOF LEVEL HVC PLN - NEW WORK

8 M-8 SHEETMETL DUCTWORK DETILS NOT TO SCLE B M-8 CEILING DIFFUSER DETIL NOT TO SCLE D M-8 FIRE DMPER DETIL NOT TO SCLE E M-8 BSE-MOUNTED PUMP DETIL NOT TO SCLE

NOTES X X GENERAL NOTES: architects planners interiors X X 1. EXISTING DEVICES AND EQUIPMENT NOT SHOWN ARE TO REMAIN. X X 2. RETURN ALL LIGHT FIXTURES

NOTES X X GENERAL NOTES: architects planners interiors X X 1. EXISTING DEVICES AND EQUIPMENT NOT SHOWN ARE TO REMAIN. X X 2. RETURN ALL LIGHT FIXTURES GENERL :. EISTING DEVICES ND EQUIPMENT NOT SHOWN RE TO REMIN. 2. RETURN LL LIGHT FITURES REMOVED TO OWNER. FORT WORTH, TES 766 F 87-338-9245 PROJECTOR SCREEN SWITCH HURST, TES 76053 F 87-284-5075 ER 02/7/207

More information

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data) Indoor Cooling Perimeter STULZ Compact CWE Computer Room ir Handlers 30-360 kw Precision ir Handlers Utilizing EC Fan Technology (60 Hz Data) EM Engineering Manual 1 STULZ Our Mission Our mission is to

More information

SCHEDULE FOR AIR CONDITIONING WORK FOR NAC BUILDING FIRST FLOOR.

SCHEDULE FOR AIR CONDITIONING WORK FOR NAC BUILDING FIRST FLOOR. A) AIR-CONDITIONING SYSTEM 1.0 Air Cooled Ductle Split Ac Supply of INVERTER split type Hi-sttic Ductle unit nd ir cooled outdoor condensing units with Inverter scroll compressor, condenser fn,outer csing

More information

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER WLL MOUNT COMBINTION GS HETER SERIES. HIGH EFFICIENCY HYDRONIC HETERS WITH BUILT-IN DOMESTIC HOT WTER XI COMBI Wall Mounted Direct Vent Sealed Combustion Quiet & Efficient On-demand Hot Water The xia series

More information

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh HETING & COOLING Product Data 58GF High-Efficiency Induced-Combustion Upflow Furnace Heating Inputs: 65,000 150,000 Btuh 78% FUE With Continuous- Pilot Ignition Carrier is the first manufacturer to provide

More information

COMPLETE WATER SOURCE HEAT PUMPS CATALOG

COMPLETE WATER SOURCE HEAT PUMPS CATALOG EZ Series 8S EZ Series 81 EZ Series WM COMPLETE WTER SOURCE HET PUMPS CTLOG EZ Series LM EZ Series EH EZ Series WC ll products are now using Environmentally Friendly HCFC and CFC FREE Refrigerants. 6140284

More information

COMPLETE WATER SOURCE HEAT PUMPS CATALOG

COMPLETE WATER SOURCE HEAT PUMPS CATALOG EZ Series 8S EZ Series 81 EZ Series WM COMPLETE WTER SOURCE HET PUMPS CTLOG EZ Series LM EZ Series EH EZ Series WC ll products are now using Environmentally Friendly HCFC and CFC FREE Refrigerants. 6140284

More information

A R I Z O N A, I N C O R P O R A T E D. LSW E n g i n e e r s COOLING TOWER REPLACEMENT

A R I Z O N A, I N C O R P O R A T E D. LSW E n g i n e e r s COOLING TOWER REPLACEMENT COVER SHEET M0. MECHNICL GENERL INFORMTION M. MECHNICL DEMOLITION PLN M. MECHNICL PLN M3. MECHNICL DETILS M4. MECHNICL SPECIFICTIONS E0. ELECTRICL SYMBOLS ND NOTES E. ELECTRICL PLN E. ELECTRICL ONELINE

More information

HVAC Project Westmoreland County Courthouse. 2 N. Main Street Greensburg, Pa SITE SITE NORTH NORTH. Elevation. Mark. Section. Mark.

HVAC Project Westmoreland County Courthouse. 2 N. Main Street Greensburg, Pa SITE SITE NORTH NORTH. Elevation. Mark. Section. Mark. Projet Diretory: HVAC Projet Westmoreland County Courthouse SITE NORTH 2 N. Main Street Greensburg, Pa List of Douments: NORTH SITE Setion Number Sheet Number Detail Number Sheet Number - XXX XXX X XXXXX

More information

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh HETING & COOLING Product Data 58WV Weathermaker 8000 High-Efficiency Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh dvanced Technology for High-Efficiency Gas Furnaces Carrier leads the industry

More information

SHOE PALACE HUNTINGTON PARK M.200

SHOE PALACE HUNTINGTON PARK M.200 M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)

More information

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS

More information

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702 04/08/2013 last saved: TRENT plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

Application guide ECOLEAN - EAC/EAR. Providing indoor climate comfort

Application guide ECOLEAN - EAC/EAR. Providing indoor climate comfort pplication guide ECOLEN - EC/ER Providing indoor climate comfort MSLE-00 2-200 CONTENTS CONTENTS Introduction and description of the components... 2 vailable options... Performance tables for the units

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

PRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION

PRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION PRPHP6 PRODUCT SPECIFICTIONS TWO STGE COMPRESSOR VRIBLE SPEED BLOWER FORM NO. PRPHP6-00 (08/207) MODEL NUMBER PRP HP 6 36 P - - PRODUCT TYPE PRP = PREMIUM RESIDENTIL PCKGED UNIT TYPE HP = HET PUMP NOMINL

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

PLUMBING STEAM PIPING RADIATION SYMBOLS ABBREVIATIONS GENERAL NOTES T CSW HSW HSWR NPW G A D WW GM WM HOT WATER HOT WATER RETURN HOT W

PLUMBING STEAM PIPING RADIATION SYMBOLS ABBREVIATIONS GENERAL NOTES T CSW HSW HSWR NPW G A D WW GM WM HOT WATER HOT WATER RETURN HOT W PLUMBING STEAM PIPING RADIATION SYMBOLS ABBREVIATIONS GENERAL NOTES 140 140 180 180 T CSW HSW HSWR NPW G A D WW GM WM HOT WATER HOT WATER RETURN HOT WATER (140 F) HOT WATER RETURN (140 F) HOT WATER (180

More information

Product Data. 58UHV, 58UXV WeatherMaker 8000VS with Comfort Heat Technology Upflow/Horizontal Furnace. Input Capacities: 60,000 thru 120,000 Btuh

Product Data. 58UHV, 58UXV WeatherMaker 8000VS with Comfort Heat Technology Upflow/Horizontal Furnace. Input Capacities: 60,000 thru 120,000 Btuh Product Data 58UHV, 58UXV WeatherMaker 8000VS with Comfort Heat Technology Upflow/Horizontal Furnace Input Capacities: 60,000 thru 120,000 Btuh Comfort Heat Technology with Variable Speed Knowhow Carrier

More information

OPERATION SERVICE AND INSTALLATION MANUAL

OPERATION SERVICE AND INSTALLATION MANUAL OPERTION SERVICE ND INSTLLTION MNUL DUCTIR Congratulations you have made a wise choice with the purchase of your Lennox are conditioning set This product has been designed, assembled and supplied in one

More information

ABBREVIATION SYMBOL DESCRIPTION ABBREVIATION DESCRIPTION W, S, D SANITARY WASTE, SOIL & DRAIN STORM DRAIN VENT - SANITARY DOMESTIC COLD WATER

ABBREVIATION SYMBOL DESCRIPTION ABBREVIATION DESCRIPTION W, S, D SANITARY WASTE, SOIL & DRAIN STORM DRAIN VENT - SANITARY DOMESTIC COLD WATER THIS DRWING IS THE PROPERTY L. SCOTT BRNRD & SSOCITES, I RCHITECTS, ND IS NOT TO BE REPRODUCED OR COPIED IN W HOLE OR IN PRT WITHOUT THE PERMISSION SME. IT IS NOT TO BE USED ON NY OTHER PROJECT ND IS TO

More information

Installation, operating and maintenance AIRCOOLAIR - LECM/LEHM. Providing indoor climate comfort

Installation, operating and maintenance AIRCOOLAIR - LECM/LEHM. Providing indoor climate comfort Installation, operating and maintenance IRCOOLIR - LECM/LEHM Providing indoor climate comfort MIL82E-0607 08-2008 WRNING: Read this manual before carrying out installation, repair or maintenance work.

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

Performance evaluation of displacement ventilation system combined with a novel evaporative cooled ceiling for a typical office in the city of Beirut

Performance evaluation of displacement ventilation system combined with a novel evaporative cooled ceiling for a typical office in the city of Beirut Avilble online t www.sciencedirect.com ScienceDirect Energy Procedi 75 (2015 ) 1728 1733 The 7 th Interntionl Conference on Applied Energy ICAE2015 Performnce evlution of displcement ventiltion system

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015 DRAWING INDEX GENERAL G0 PLUMBING P00 P0A P0B P0C P0A P0A P0B COVER SHEET PLUMBING LEGEND AND GENERAL NOTES PLUMBING PLAN PLUMBING PLAN PLUMBING PLAN PLUMBING ROOF DEMOLITION PLAN PLUMBING ROOF REMODEL

More information

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3 Existing System Evaluation Executive Summary The MBNA Career Services Center is a 44,000 square foot, 4-story office type building at Penn State University, University Park Campus. The building is located

More information

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140 CBL LOW-BOY OIL FURNCE INPUT RTES: 70,000 thru 154,000 BTUH SERIES 140 Product Data THE LTEST IN OIL FURNCE TECHNOLOGY 96280 The model CBL combines high efficiency and quiet operation with oil heating

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

EVH SPACE TECHNICAL BULLETIN BT05L002GB-04 WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

EVH SPACE TECHNICAL BULLETIN BT05L002GB-04 WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP TECHNICL BULLETIN EVH SPCE - 1 WTER TO IR DUCTBLE INDOOR HORIZONTL HET PUMP The EVH SPCE single-compressor units are available in sizes, with a complete series of accessories and feature very high efficiency

More information

EXIST 54"x64"x3" CONCRETE HOUSEKEEPING PAD. RL RL RL RL RS RS RS RS ROUTE REFRIGERANT PIPING UNDER OVERHANG ABV.

EXIST 54x64x3 CONCRETE HOUSEKEEPING PAD. RL RL RL RL RS RS RS RS ROUTE REFRIGERANT PIPING UNDER OVERHANG ABV. C ELECTRIC STAIR CONFERENCE PHOTO LAB ROOM RECEIVING MEN PROC. WOMEN EQUIP. REFERENCE C JAN MICROFILM OFFICE OFFICE STAIR C FILE STORAGE WATER METER ROOM C C EXIST 54"x64"x" CONCRETE HOUSEKEEPING PAD.

More information

Technical Report #2. Newseum and Freedom Forum Headquarters. Washington, D.C. Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007

Technical Report #2. Newseum and Freedom Forum Headquarters. Washington, D.C. Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007 Technical Report #2 Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007 Newseum and Freedom Forum Headquarters Washington, D.C. Table of Contents Power Distribution Systems Executive Summary

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

HEAVY DUTY HEATING & AIR CONDITIONING UNITS & ALL MAKES PARTS. ISSDistribution.com - Call (800)

HEAVY DUTY HEATING & AIR CONDITIONING UNITS & ALL MAKES PARTS. ISSDistribution.com - Call (800) HEVY DUTY HETING & IR CONDITIONING UNITS & LL MKES PRTS 2011 RED DOT UNITS ON ROD R-5045 BCKWLL Heater/ir Conditioner Unit RMORED CRS ID CRS PERSONNEL CRRIERS The R-5045 Series offers the highest capacity

More information

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

AIR HANDLER DESIGN WORK SHEET

AIR HANDLER DESIGN WORK SHEET AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD]

More information

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan. Appendix B Symbols for Drawings Table B.1 Air moving devices and ductwork symbols Air Movement Fans Axial flow fan Centrifugal fan Propeller fan Intake roof ventilator (supply) Exhaust roof ventilator

More information

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH R22 IR COOLED HIGH STTIC DUCTED SPLIT SYSTEM Single & Double Skin Evaporator Units Cooling Capacity : 80 to 750 MBH Innovative Outstanding DESIGN & PERFORMNCE IR COOLED CONDENSING UNITS SYSTEM FETURES

More information

UESC STEAM DECENTRALIZATION BUILDING - 326

UESC STEAM DECENTRALIZATION BUILDING - 326 0% REVIEW 0// B FINL UESC STEM DECENTRLIZTION BUILDIN - 6 NVFC DW NO. CMP LEJEUNE CONTRCT NO. SHT NO. SHEET TITLE 6--00 COVER SHEET ND DRWIN INDEX 6-M-00 MECHNICL BBREVITIONS, LEENDS ND NOTES 6-MD-0 MECHNICL

More information

deltaclima CoolWall We provide you with the perfect air-conditioning solution for your computer centre!

deltaclima CoolWall We provide you with the perfect air-conditioning solution for your computer centre! deltclim CoolWll We provide you with the perfect ir-conditioning solution for your computer centre! Weiss Klimtechnik GmbH Pssion for Climte deltclim CoolWll Greter performnce, lower energy consumption,

More information

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm) Heat Recovery Units AIR HANDLING UNIT No. SERVICE AREA MANUFACTURER MODEL HRU-3 & HRU-4 B-Section Low Rate Ventilation Tempeff RG 16000 (9500) SUPPLY FAN - SIZE/TYPE AIRFLOW RATE (cfm) (l/s) TOTAL STATIC

More information

HEAT PUMPS LINE AS AIR TO WATER

HEAT PUMPS LINE AS AIR TO WATER HET PUMPS LINE S IR TO WTER EROGOR ECO INVERTER LL-IN-ONE EROGOR ECO INVERTER EROGOR POWER EVI INVERTER SUPER PERFORMNCE Heating Cooling Domestic hot water SUPER DVNTGE Wifi module included Big touch screen

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS INSTLLTION INSTRUCTIONS WLL MOUNTED PCKGE HET PUMPS Models SH261 SH311 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-409 Supersedes: 2100-409 File:

More information

COTES ALL-ROUND THE C35 RANGE

COTES ALL-ROUND THE C35 RANGE EPERTS IN HUMIDITY MNGEMENT COTES.COM DEHUMIDIFICTION THE WY YOU WNT IT C35 DEHUMIDIFIER IDEL FOR USE IN > PHRMCEUTICL PRODUCTION FCILITIES > FOOD INDUSTRY PROCESSING FCILITIES > COLD STORES/FREEZER FCILITIES

More information

HOT WATER SYSTEMS.

HOT WATER SYSTEMS. HOT WTER SYSTEMS www.thermann.com.au GS STORGE HOT WTER SYSTEM THE THERMNN 4* GS HOT WTER HETER CN SUIT NY FMILY TYPE. WITH N DJUSTLE THERMOSTT FOR SFETY ND EFFICIENCY IT LLOWS YOU TO E IN CONTROL OF YOUR

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL

More information

Advanced Product Data

Advanced Product Data 48PD and 50PD-05, 06 Displacement Ventilation or Single-Zone Variable Airflow Rooftop Units Single Package, Electric Cooling, Gas or Optional Electric Heating with PURON (R-410A) Refrigerant and COMFORTLink

More information

HOT WATER SYSTEMS. thermann.com.au

HOT WATER SYSTEMS. thermann.com.au HOT WTER SYSTEMS thermann.com.au 2 HOT WTER YOU CN DEPEND ON Precision engineered for efficiency and long life, Thermann is setting new standards for hot water systems in ustralia. Packed with innovative

More information

KompaKt. air Handling Units

KompaKt. air Handling Units ir Hndling Units KompKt escription of Komfovent kompkt units 2 KOMPAKT REGO RHP 3 Resons to choose Komfovent kompkt units 4 ontrol System 6 KOMFOVENT KOMPAKT REGO 10 Rotry Het Exchnger 11 Stndrd Sizes

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 May 05 Supersedes January 05 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS... CENTRL CHILLERS Designed For Outdoor Installation Single or Multiple Refrigeration Zones Microprocessor Control Instrument - Capacity Integral ir-cooled Condenser Fluid Temperatures of 0 F - 70 F TTOCS

More information

MONROE MIDDLE SCHOOL SCHOOL

MONROE MIDDLE SCHOOL SCHOOL MONROE MIDDLE SCHOOL SCHOOL MONOE MIDDLE SCHOOL EUGENE, OR 97401 C001 COVER SHEET M001 MECHANICAL NOTES, SYMBOLS & ABBREVIATIONS M100 MECHANICAL PARTIAL PLANS DEMOLITION M101 MECHANICAL PARTIAL PLANS NEW

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY

More information

Liebert PDX and PCW Thermal Management Systems

Liebert PDX and PCW Thermal Management Systems Liebert PDX and PCW Thermal Management Systems 3 to 8 Ton (11 to 29 kw) Nominal Capacity, Upflow and Downflow, 60 Hz, Air-, Water-, Glycoland Chilled-water-cooled Models System Design Catalog Technical

More information

ML 1 93 UH 070 x P 36 B

ML 1 93 UH 070 x P 36 B PRODUCT SPECIFICTIONS GS FURNCES ML93UH MERIT SERIES Upflow / Horizontal Bulletin No. 20588 October 202 Supersedes ugust 202 FUE - 93% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

REFRIGERANT PIPING (LINE SET) CONDENSATE DRAIN PIPING SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE SIDE WALL SUPPLY GRILLE CONNECT TO EXISTING

REFRIGERANT PIPING (LINE SET) CONDENSATE DRAIN PIPING SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE SIDE WALL SUPPLY GRILLE CONNECT TO EXISTING VENTILATION RATE SUMMARY PER 0 NORTH CAROLINA BUILDING CODE, PRIVATE DWELLING SINGLE AND MULTIPLE LIVING AREAS - BEDROOMS UNIT NAME: UNIT B and B HC BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.0

More information

GRILLE, REGISTER AND DIFFUSER SCHEDULE

GRILLE, REGISTER AND DIFFUSER SCHEDULE ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 March 08 Supersedes February 08 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

50 Disassembly and assembly SEN

50 Disassembly and assembly SEN 50 Disssembly nd ssembly SEN01053-01 7. Disconnect filter (5). 8. Disconnect clmp (6). 14. Disconnect rditor lower hoses (13) (15). [*1] 9. Disconnect filter (7). Disconnect the hose clmp. 15. Disconnect

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

INSTALLER REFERENCE GUIDE

INSTALLER REFERENCE GUIDE INSTALLER REFERENCE GUIDE + ERHQ0BA ERHQ04BA ERHQ06BA ERLQ0CA ERLQ04CA ERLQ06CA EHVH6S8CA EHVH6S6CA EHVX6S8CA EHVX6S6CA Tble of contents Tble of contents About the documenttion. About this document...

More information

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning : Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning Industrial GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 284 1513 -CLSS rcgroupairconditioning

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

Product Data. 58TUA WeatherMaker Speed High-Efficiency Upflow Furnace. Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58TUA WeatherMaker Speed High-Efficiency Upflow Furnace. Input Capacities: 40,000 thru 135,000 Btuh Product Data 58TU WeatherMaker 8000 2-Speed -Efficiency Upflow Furnace Input apacities: 40,000 thru 135,000 Btuh Two-Speed Heating for -Efficiency Gas Furnaces arrier leads the industry with our new WeatherMaker

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

G-1 STREET MAP SITE VICINITY PLAN ARCHITECTURAL A-1 FLOOR PLAN A-2 REFLECTED CEILING PLAN A-3 POWER PLAN A-4 ACCESSIBILITY GUIDELINES G-1 CODE DATA

G-1 STREET MAP SITE VICINITY PLAN ARCHITECTURAL A-1 FLOOR PLAN A-2 REFLECTED CEILING PLAN A-3 POWER PLAN A-4 ACCESSIBILITY GUIDELINES G-1 CODE DATA RCHITECTS ENGINEERS, INC. MECHNICL M-1 MECHNICL NOTES, SCHEDULES, ND DETILS OVERLL UILDING PLN PLUMING (Y OTHERS) P-1 PLUMING PLN SCLE: N.T.S. ELECTRICL (Y OTHERS) E-1 ELECTRICL PLN 370 15th ve S; Units

More information

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster Rooftop Units CV Reheat RTU Reheat Reheat system RTU, serving electric reheat coils, w/dehumidification cycle & RA CO2 override of OAD CV Single Zone RTU SZ (from PC) RTU SZ Generic RTU SZ Multiple Units

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 0-00 F Portable Chillers ir & Water-Cooled 0-70 F Central Chillers ir & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-0 gallons

More information

HE SERIES, DE SERIES & RE SERIES

HE SERIES, DE SERIES & RE SERIES INSTLLTION, OPERTION ND MINTENNCE MNUL FOR HE SERIES, DE SERIES & RE SERIES DIRECT FIRED HETING UNITS INDOOR ND OUTDOOR MODELS UNIT MODEL NO. UNIT SERIL NO. SERVICED BY: TEL. NO: CNDIN HED OFFICE ND FCTORY

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

AHC-2. OUTDOOR AIR HANDLERS Application Manual

AHC-2. OUTDOOR AIR HANDLERS Application Manual AHC-2 OUTDOOR AIR HANDLERS Application Manual Contents 2 PAGE GENERAL INFORMATION 2 FEATURES AND BENEFITS 3 UNIT NUMBER DESCRIPTION 4 AIR HANDLER SELECTION 5 AIR HANDLER 5,6 PACKAGED ROOFTOP ARRANGEMENTS

More information

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual Engineering Manual From 1 to 3 Tons MC-2x2-2x2 MissionCritical Vertical Floor Mounted A/C s (Single Circuit DX & CW) R407C & R410a Data ta 1 to 3 Tons Compact 24 W x 24 D Footprint Features & Benefits

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models HLS-55 through HLS-150

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models HLS-55 through HLS-150 SEPTEMBER 00 P/N 3-066-C 950 MECHANIC STREET LAKE CITY, PA 63 PHONE:8-77-63 FAX: 8-77-38 INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models through HLS-50

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

I. Introduction and Arrangement

I. Introduction and Arrangement Joseph Firrantello - Mechanical Option Primary Faculty Consultant: Freihaut Laboratory Facility, Eastern Pennsylvania Mechanical Assignment 3 Existing Conditions Report 11.14.03 Executive Summary The purpose

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

ADDENDUM #2. BIDS CLOSE TUESDAY, May 8, 2018 at 1:00 p.m. (C.D.T.)

ADDENDUM #2. BIDS CLOSE TUESDAY, May 8, 2018 at 1:00 p.m. (C.D.T.) Proposed multi-purpose facility addition for -- School District of Shiocton. Village of Shiocton, Wisconsin ADDENDUM #2 Project #65140 May 4, 2018 BIDDERS are informed that the plans and specifications

More information