INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models HLS-55 through HLS-150

Size: px
Start display at page:

Download "INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models HLS-55 through HLS-150"

Transcription

1 SEPTEMBER 00 P/N C 950 MECHANIC STREET LAKE CITY, PA 63 PHONE: FAX: INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER models through HLS-50 /80 HLS-0/50 READ ALL INFORMATION IN THIS MANUAL BEFORE BEGINNING INSTALLATION OR OPERATION OF THE DRYER. BEFORE STARTING INSTALLATION AND/OR MAINTENANCE PROCEDURES, TURN OFF THE MAIN POWER TO THE DRYER AND COMPLETELY DEPRESSURIZE THE UNIT TO PREVENT PERSONAL INJURY. DO NOT REMOVE, REPAIR, OR REPLACE ANY ITEM ON THIS DRYER WHILE IT IS UNDER PRESSURE. NEVER OPERATE THIS DRYER ABOVE THE RATED OPERATING CONDITIONS. OPERATION ABOVE SPECI- FIED CONDITIONS WILL RESULT IN DECREASED PERFORMANCE, POSSIBLE DAMAGE TO THE UNIT AND/ OR PERSONAL INJURY. SEE BACK OF THIS MANUAL FOR ADDITIONAL SAFETY INSTRUCTIONS PRINTED IN THE U.S.A. PAGE

2 HANDLING THE DRYER SECTION. HANDLING INSTRUCTIONS DO NOT LIFT THE DRYER BY THE INLET PIPING OR CONTROL BOX. THESE COMPONENTS ARE NOT DESIGNED TO HOLD THE WEIGHT OF THE DRYER. PERSONAL INJURY AND/OR EQUIPMENT DAMAGE MAY RESULT. Lift the dryer by the outlet (top) piping or vessel center connector br. When lifting the unit mke sure tht the chins or cbles re cler of ll tubing nd frgile components.. STORAGE INSTRUCTIONS The idel plce to store the unit is indoors. The loction should be free from corrosive gsses nd extreme humidity. These conditions will cuse dmge to the unit. The unit should be covered with trpulin to keep the unit clen. If the unit is to be stored outdoors, it MUST BE covered completely. The cover must be dequte enough to prevent rin or snow from ccumulting on the dryer. The loction must be free of stnding wter nd mud. The preferred loction if outdoors, is on pved surfce..3 EQUIPMENT CHECK Inspect the dryer for ny dmge tht my hve occurred during shipment. Inspect ll fittings, piping connections, fsteners, etc. for loose connections. Also check guges for crcks or brekge. IF DRYER HAS BEEN DAMAGED DURING SHIPMENT: () NOTIFY CARRIER IMMEDIATELY AND FILE A CLAIM. () CONSULT FACTORY BEFORE OPERATING THE DRYER. SAFETY INSTRUCTIONS SECTION. HANDLING DO NOT LIFT THE DRYER BY INLET (BOTTOM) PIPING OR CONTROL BOX. THESE COMPONENTS ARE NOT DESIGNED TO HOLD THE WEIGHT OF THE DRYER. PERSONAL INJURY AND/ OR EQUIPMENT DAMAGE MAY RESULT. MAKE SURE THAT ALL EQUIPMENT BEING USED TO LIFT THE DRYER IS CAPABLE OF LIFTING THE WEIGHT OF THE DRYER..3 OPERATION DO NOT OPERATE DRYER IF THERE IS A LEAK IN EITHER VESSEL. IMMEDIATELY TAKE THE DRYER OUT OF SERVICE. ANY DAMAGE TO THE VESSELS CAN MAKE THEM UNSAFE TO USE. INSPECT OUTSIDE AND INSIDE OF VESSELS REGULARLY FOR CORROSION AND ANY DAMAGE (I.E., DENTS, GOUGES OR BULGES). IF DAMAGED, TAKE OUT OF SERVICE IMMEDIATELY. IF THE DRYER IS TO BE TRANSPORTED OVERHEAD, MAKE SURE THAT ALL PERSONNEL ARE ALERTED AND SAFETY PROCEDURES ARE FOLLOWED.. INSTALLATION BEFORE STARTING INSTALLATION AND/OR MAINTENANCE PROCEDURES, TURN OFF POWER AND DEPRESSURIZE UNIT TO PREVENT INJURY. SERIOUS PERSONAL INJURY MAY RESULT IF THESE SAFETY RULES ARE NOT FOLLOWED. DO NOT REMOVE, REPAIR, OR REPLACE ANY ITEM ON DRYER WHILE IT IS UNDER PRESSURE. TURN OFF MAIN POWER TO THE DRYER AND DEPRESSURIZE THE DRYER COMPLETELY BEFORE STARTING INSTALLATION AND/OR MAINTENANCE PROCEDURES. WHEN INSTALLING AND OPERATING THIS EQUIPMENT, COMPLY WITH THE NATIONAL ELECTRICAL CODE AND ANY APPLICABLE FEDERAL, STATE, AND LOCAL CODES. WHEN INSTALLING THIS DRYER, MAKE SURE THAT THE NEMA RATING OF THE CONTROL BOX IS APPLICABLE TO THE INSTALLATION. MAKE SURE THAT ALL CUSTOMER SUPPLIED WIRING AND ELECTRICAL DEVICES ARE PROPERLY SIZED TO HANDLE THE ELECTRICAL REQUIREMENTS OF THE DRYER. DO NOT OPERATE THIS DRYER ABOVE THE MAXIMUM RATED WORKING PRESSURE. OPERATING CONDITIONS FOR PROPER PERFORMANCE OF THIS DRYER ARE DIFFERENT THAN MAXIMUM OPERATING CONDITIONS FOR THE VESSELS. BE SURE TO CHECK THE DRYER OPERATING CONDITIONS. SEE SECTION 3.. USE THIS DRYER FOR COMPRESSED AIR ONLY. AIR FROM THIS DRYER IS NOT SUITABLE FOR BREATHABLE AIR SYSTEMS WITHOUT FURTHER TREATMENT. DO NOT OPERATE THIS DRYER IF EITHER VESSEL HAS BEEN DAMAGED BY FIRE. TAKE OUT OF SERVICE IMMEDIATELY.. MAINTENANCE DO NOT REMOVE, REPAIR, OR REPLACE ANY ITEM ON THE DRYER WHILE IT IS UNDER PRESSURE. TURN OFF MAIN POWER TO THE DRYER AND DEPRESSURIZE THE DRYER COMPLETELY BEFORE STARTING MAINTENANCE PROCE- DURES. DO NOT WELD OR GRIND ON EITHER VESSEL. IT WILL NOT BE SAFE TO OPERATE. ALWAYS WEAR EYE PROTECTION, GLOVES AND A RESPIRATORY PROTECTIVE DEVICE WHEN HANDLING THE DESICCANT. THE DUST FROM THE DESICCANT MAY CAUSE EYE AND SKIN IRRITATION. AVOID BREATHING THE DUST AND PROLONGED CONTACT WITH THE SKIN. FIRST AID IN CASE OF EYE CONTACT WITH DESICCANT DUST; IMMEDIATELY FLUSH THE EYES WITH PLENTY OF WATER FOR AT LEAST 5 MINUTES. CONSULT A PHYSICIAN. PAGE PRINTED IN THE U.S.A.

3 DIMENSIONS AND SPECIFICATIONS SECTION 3 3. DRYER SPECIFICATIONS WEIGHT (with desiccnt instlled) lbs lbs HLS lbs HLS lbs DIMENSIONS See SECTION 3. IN/OUT CONNECTION.../"NPT..."NPT HLS-0..." NPT HLS-50..."NPT VESSELS (desiccnt towers) Design Pressure PSIG Design Temperture O F TO 00 O F PIPING Threded pipe fittings: ANSI B6.3 Threded union fittings: ANSI B6.39 Pipe: Crbon Steel, Schedule 0 VALVES Inlet... -Wy, solenoid piloted Outlet... Shuttle vlve Purge... 3-Wy Vlve (run s -Wy Vlve), solenoid piloted CONTROL AIR FILTER Construction... Zinc housing 3. DIMENSIONS Models through HLS-50 ELECTRICAL Nem Electricl enclosure Stndrd 5V... 5V/PH/50-60Hz Optionl 30V:... 30V/PH/50-60Hz DESICCANT Mteril... Activted Alumin, /8" (-5 MM) Bed type Quntity Per Tower (LBS) lbs lbs HLS lbs HLS lbs OPERATING CONDITIONS Inlet Air Pressure... MIN 60 PSIG... MAX 50 PSIG Inlet Air Temperture... MIN 0 O F... MAX 0 O F Ambient Air Temperture.. MIN 0 O F... MAX 0 O F RATED INLET CONDITIONS Inlet Air Pressure PSIG Inlet Air Temperture O F Reltive Humidity (sturtion)... 00% RH HLS-0 HLS-50 HLS-0 HLS-50 * (ROTATED TO BACK ON HLS-50) & HLS-0 & HLS-50 PRINTED IN THE U.S.A. PAGE 3

4 INSTALLING THE DRYER SECTION. LOCATION A colescing prefilter must be instlled before the dryer to remove lubricting oils, dust nd pipe scle contmintion. It is DO NOT INSTALL THIS DRYER IN AN ENVIRONMENT OF recommended tht high efficiency colescing filter with n CORROSIVE CHEMICALS, EXPLOSIVE GASSES, POISONOUS utomtic drin or electric drin vlve be instlled. The filter should GASSES, OR SATURATED STEAM HEAT. be equipped with pressure differentil indictor to monitor the condition of the element. Locte dryer in protected, well vented re where mbient tempertures re between 0 o F nd 0 o F. If this dryer must be instlled where mbient tempertures re below 0 o F, insultion nd het trcing must be properly instlled on the inlet piping, purge exhust line nd the desiccnt towers to prevent freezing of the equipment. Position the dryer in the upright position on solid, level, vibrtion free surfce cpble of supporting the dryer s weight. Allow sufficient clernce over nd round the dryer. Refer to SECTION 3. for dryer dimensions. The dryer should not be locted in extremely dirty res where irborne contminnts cn ccumulte on the dryer. If this cnnot be prevented, the dryer should be clened periodiclly.. PIPING AND ANCILLARY EQUIPMENT IMPORTANT Mke sure tht the inlet ir piping is connected to the bottom nd the outlet ir piping is connected to the top of the dryer. Mke sure tht the inlet nd outlet piping to nd from the dryer is properly supported. Excessive stress my cuse dmge nd/or dryer mlfunction. Remove protective cps or covers from ll vlves before instlling this dryer. If this dryer is to be instlled into n existing piping system, clen the existing inlet piping to remove ll ccumulted dirt, pipe scle, etc., before connecting the dryer. Mke sure tht the inlet nd outlet shutoff vlves re tightly closed before connecting to the existing piping system. When instlling the piping nd ny dditionl components, mke sure tht dequte pipe supports re used. Excessive stress on the dryer nd components my cuse dmge or premture filure. Use either overhed or stiff-leg type supports. Mke sure tht the piping is correctly connected to the dryer. The inlet is the bottom connection nd the outlet is the top connection. Reference SECTION 3. for dryer dimensions nd connection loctions. Once the loction hs been determined, plce the dryer into position. Reference SECTION for hndling instructions..- BYPASS PIPING (optionl) The instlltion of bypss piping is not required, but will llow the dryer nd filter(s) to be tken off strem without interrupting the ir system. A prticulte fterfilter should be instlled downstrem of the dryer. The fterfilter will remove ny desiccnt dust. The fterfilter should be equipped with pressure differentil indictor to monitor the condition of the element. Mke sure tht the filters re properly instlled ccording to the instructions provided with them..3 REMOTE PURGE EXHAUST PIPING To reduce the noise during purging nd tower depressuriztion, this dryer ws supplied with muffler for instlltion on the purge exhust vlve. If the sound or humidity dischrged from this dryer is uncceptble, the purge of this dryer cn be piped remotely wy. IMPORTANT Mke sure tht the piping is s short s possible nd does not crete bck pressure on the dryer. To prevent liquid ccumultion in the piping nd purge vlve, the piping must be t the sme level or lower thn the purge vlve. The purge line must be vented to tmospheric pressure. If the mbient temperture t the venting end of the piping is subject to tempertures below 3 o F, freeze protection must be instlled. The purge vlve hs threded pipe connections. Reference Section 3. for loction. Use dequte pipe supports on the piping to prevent stress on the vlve. The distnce will determine the size of piping tht is recommended. For distnces of 0 feet or less, use piping of the sme size s the purge vlve. For distnces up to 0 feet, use piping one size lrger thn the purge vlve.. INSTALLING PRESSURE RELIEF VALVES CAUTION THESE VESSELS MUST BE PROTECTED BY PRESSURE RELIEF VALVES. Refer to OSHA Pr. b, Sub. Pr (3) nd ASME Boiler nd Pressure Vessel Code, Section VIII, Division, UG-5 through UG-36. Also check government regultions, i.e., stte nd locl codes. Relief vlve connection ports were NOT provided on this dryer. It is recommended tht relief vlves be instlled to comply with ll pplicble codes. The relief vlves should be full flow type, rted for the dryer operting conditions. For recommended loction see Figure A..5 INSTALLING THE PURGE MUFFLER To reduce the sound level during purge nd tower depressuriztion, this dryer ws supplied with muffler for instlltion on the purge exhust vlve. For muffler loction Reference SECTION 3.. In Figure A, recommended bypss piping lyout nd dditionl components re shown. Bsic bypss piping should include n inlet isoltion vlve, bypss vlve, nd n outlet isoltion vlve. The isoltion nd bypss vlves must be bubble-tight..- FILTERS CAUTION A PROPERLY RATED COALESCING PREFILTER MUST BE INSTALLED BEFORE THE DRYER TO REMOVE LUBRICATING OILS, DUST AND PIPE SCALE CONTAMINATION. FAILURE TO USE A PREFILTER WILL RESULT IN DAMAGE TO THE DRYER AND VOIDS THE WARRANTY. Mke sure tht the elements re instlled in ll filter housings prior to strt up. PAGE The muffler ws shipped seprtely. It should NOT be instlled until the dryer hs been operted for severl hours. From desiccnt instlltion, some dust my be present in the desiccnt towers. Operting the dryer with the muffler instlled immeditely fter the towers hve been filled with desiccnt or t initil strt up my cuse the muffler to clog. IMPORTANT The dryer must be operted for severl hours without the muffler fter the towers hve been filled with desiccnt. This will prevent the muffler from becoming clogged. PRINTED IN THE U.S.A.

5 INSTALLING THE DRYER SECTION FIGURE A RECOMMENDED PIPING CONFIGURATION AND COMPONENTS MODEL HLS-0 HLS-50 DRYER IN/OUT /" NPT(F) " NPT(F) " NPT(F) " NPT(F) PREFILTER MODEL IN/OUT DEL-P INDICATOR MODEL AFTERFILTER MODEL IN/OUT DEL-P INDICATOR MODEL F /-C-AD F /-C-AD F C-AD F C-AD /" NPT(F) 3/" NPT(F) " NPT(F) " NPT(F) F /-RB-MD F /-RB-MD F RB-MD F RB-MD /" NPT(F) 3/" NPT(F) " NPT(F) " NPT(F).6 ELECTRICAL CONNECTIONS SERIOUS PERSONAL INJURY AND DAMAGE TO THE DRYER WILL OCCUR IF THE DRYER IS CONNECTED TO A POWER SOURCE OTHER THAN THE VOLTAGE LISTED ON THE DATA TAG. WHEN INSTALLING THE ELECTRICAL CONNECTIONS FOR THIS DRYER, COMPLY WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. Check the electricl rting of the dryer s listed on the dryer dt tg. Mke sure tht the power source is correct for the dryer rting. Remove the box cover to ccess the power supply nd lrm terminls. Wire the power supply s shown in Figure B. Connect the wiring nd necessry components to the dryer box. Comply with ll codes pplicble for this instlltion. The power supply to the dryer will be connected into the dryer control box. A 7/8" di hole ws provided in the bottom of the box for the connection of conduit or cord grip connector. FIGURE B ELECTRICAL CONNECTIONS PRINTED IN THE U.S.A. PAGE 5

6 START UP SECTION 5 5. START UP BEFORE STARTING THIS DRYER, FOLLOW THE INSTALLATION INSTRUCTIONS AND PROCEDURES COMPLETELY. SERIOUS PERSONAL INJURY CAN RESULT IF INSTRUCTIONS ARE NOT CAREFULLY AND COMPLETELY FOLLOWED. DO NOT REMOVE, REPAIR, OR REPLACE ANY ITEM ON THIS DRYER WHILE IT IS UNDER PRESSURE. 5. PURGE FLOW ORIFICE DRYER MODEL HLS-0 HLS-50 ORIFICE SIZE 3/3" DIA 7/6" DIA 9/6" DIA 5/3" DIA FLOW AT 00 PSIG 9.5 SCFM.9 SCFM. SCFM 6. SCFM BLANK ORIFICE P/N IMPORTANT TO START THE DRYER YOU MUST PRESS THE RUN SWITCH WHICH WILL LIGHT THE RUN LED. If the dryer is being strted up for the first time or fter the desiccnt hs been chnged, the purge muffler must be removed. Operte the dryer until no desiccnt dust is visible t the purge vlve. Then the muffler cn be reinstlled. If bypss piping ws instlled on this dryer s outlined in SECTION., close the inlet nd outlet isoltion vlves. Open the bypss vlve. Pressurize the ir system. Once the ir system is pressurized, slowly open the inlet isoltion vlve. Check timing settings in control box. The dryer should be fctory set s shown in Figure B. Energize the power supply to the dryer. Both towers will pressurize. Severl seconds lter one tower will depressurize. Open the outlet isoltion vlve. The Purge Orifice is locted t the top of the outlet vlve. Purge cn be djusted by tking blnk orifice nd drilling new size hole. 5.3 CONDITIONING THE DESICCANT BED To condition the desiccnt bed, the dryer is operted without ny outlet flow, while the towers regenerte with purge ir. Close the outlet isoltion vlve nd pressurize the system. Energize the power supply nd strt the dryer. Observe the dryer for severl cycles. Mke sure tht it is operting properly. At initil strt up or fter extended shutdowns (over one month), the dryer my tke to 8 hours of continuous opertion for the bed to be conditioned. Moisture tht hs ccumulted on the desiccnt bed should be removed before the dryer is plced on strem. PRINCIPLE OF OPERATION SECTION 6 6. PRINCIPLE OF OPERATION HLS Series Hetless Regenertive Air Dryers utilize the pressure swing principle of opertion. The desiccnt bed in one tower dries the ir strem while the desiccnt bed in the other tower is regenerted. A purge of dry ir is used for tower regenertion. It is tken from the outlet of the dryer. To llow the correct mount of dry ir to flow into the regenerting tower, dryers re equipped with purge metering orifice. The het creted during dsorption of moisture in the drying tower is retined in the desiccnt bed nd increses the moisture removl cpcity of the purge ir. When the dryer is pressurized nd the power supply to the dryer is energized, the dryer will begin opertion. To chieve mximum performnce from this dryer, it should be operted continuously. Operting this dryer for single shift periods my result in vried outlet dew point performnce. The dryer opertion consists of four stges; REPRESSURIZATION, CHANGEOVER/DEPRESSURIZATION, DRYING nd REGENERATION. 6.- REPRESSURIZATION STAGE Repessuriztion occurs in the regenerting tower. Repessuriztion must occur before tower chngover. This reduces shock to the desiccnt nd the possibility of downstrem pressure spikes. The purge vlve is closed nd the purge ir, which ws vented to tomosphere erlier in the cycle, is now used to repressurize the regenerted tower. The regenertion stge of one tower occurs t the sme time s the drying stge in the opposite tower. During the regenertion stge, percentge of dry ir is directed through the desiccnt bed of the offstrem tower. The purge ir is vented through the purge vlve to the tmosphere. FIGURE 6A PNEUMATIC SCHEMATIC 6.- CHANGEOVER/DEPRESSURIZATION STAGE Tower chngeover occurs fter the previous regenerting tower is pressurized. The controller signls the inlet trnsfer vlve to switch. The tower tht ws on line nd drying the process ir will begin to depressurize DRYING AND REGENERATION STAGE During the drying stge, one tower is pressurized with process ir. This tower is in the drying stge. The process ir psses through the desiccnt bed, which dsorbs moisture from the ir. PAGE 6 PRINTED IN THE U.S.A.

7 USING THE DRYER SECTION 7 7. CONTROLLER The Controller is compct NEMA control box. It hs the following fetures: Dryer Sttus LEDs - POWER ON LED - L/R TOWER DRYING LEDS - RUN LED - L/R TOWER REGENERATING LEDS - HOLD LED - DRYER PURGING LED - SWITCHING FAILURE LED The Dryer Sttus LEDs re locted on the front pnel of the control box. Figure 7A shows the loction of ech. FIGURE 7A When the Left tower is pressurized nd on line drying the process ir, the corresponding LEFT TOWER DRYING LED is illuminted. When the right tower is pressurized nd on line drying the process ir, the corresponding RIGHT TOWER DRYING LED is illuminted. POWER ON STOP RUN RUN The DRYER PURGING LED is illuminted when the purge exhust vlve is energized open. During repressuriztion this LED will not be illuminted. Repressuriztion occurs for pproximtely 0 seconds just before tower chngeover. The opertion sequence of the dryer is shown in FIGURE 7B TIMING CHART. SWITCHING FAILURE: When there is switching filure, the LED will be lit. This will energize the contcts shown in FIGURE B. The contcts cn be wired for remote nnuncition. To reset the Switching Filure Alrm press the run button on the control box front pnel. HOLD TOWER DRYING TOWER REGENERATING SWITCHING FAILURE HOLD FEATURE: For low lod or sttic pressure conditions, the hold contcts shown on Figure B cn be wired to n uxillry set of normlly closed contcts on the compressor strter. This will stop the cycling of the dryer nd repressurize both towers of the dryer, until there is demnd on the compressor. The Hold LED will light, if the dryer is wired s described nd the compressor is not running. 7. SETTING THE CYCLE TIME Reference Figure B: The setting for the time cycle is 5 min/hlf cycle. For the hlf cycle time setting, the switches indicted for DS (, 5, 7, & 8) s shown in the CYCLE TIME DETAIL hve been fctory set by pushing the switches up. The vlues for these switches re (56, 3, 8, & ) sec., so when dded together equl 300 sec or 5 min. WE DO NOT RECOMMEND time cycle setting below min/hlf cycle. For this hlf cycle time setting, the switches tht need to be pushed up re DS (, 5, 6, & 7) there vlues re (6, 3, 6, & 8) sec. so when dded together equl 0 sec or min. The setting for the pressuriztion time is 0 sec. For the pressuriztion time setting, the switches indicted for DS ( & ) s shown in the CYCLE TIME DETAIL hve been fctory set by pushing the switches up. The vlues for these switches re (6 & ) sec., so when dded together equl 0sec. WE DO NOT RECOMMEND CHANG- ING THIS SETTING. LEFT DRYER PURGING RIGHT The setting for the lrm time is 96 sec. For the lrm time setting, the switches indicted for DS (5 & 6) s shown in the CYCLE TIME DETAIL hve been fctory set by pushing the switches up. The vlues for these switches re (6 & 3) sec., so when dded together equl 96 sec. WE DO NOT RECOMMEND CHANGING THIS SETTING. NOTE: THE ALARM TIME SETTING NEEDS TO BE LESS THEN THE HALF CYCLE TIME SETTING OR THIS WILL NEGATE THE ALARM FUNCTION. IMPORTANT Operting this dryer on the minute cycle will more thn double the wer on the dryer components. To reduce wer on the dryer, operte the dryer on the 0 minute cycle if the -0 O F dew point is cceptble. FIGURE 7B CYCLE TIMING CHART PRINTED IN THE U.S.A. PAGE 7

8 SHUTDOWN SECTION 8 8. SHUTDOWN PROCEDURES Shutoff the ir supply to the dryer. If bypss piping nd vlves were instlled, close the inlet nd outlet isoltion vlves nd open the bypss vlve. Let the dryer cycle until it is totlly depressurized. MAINTENANCE & TROUBLESHOOTING SECTION 9 9. DAILY INSPECTION The following procedures should be performed dily: Check the dryer operting conditions, inlet temperture, mbient temperture, inlet pressure nd inlet flow. Monitor the dryer for one complete cycle. Mke sure tht it is operting properly. Visully check the dryer nd piping for dmge. Check the purge muffler. Purge ir should be exhusting from the vlve. If oil is present, the dryer nd ir system my be contminted with lubricnts. Inspect ll upstrem equipment, ftercoolers, seprtors, drins nd filters. Mke sure tht ll bypss vlves re tightly closed. Check the prefilter(s) for proper drining. If the prefilter is not equipped with n utomtic drin, it must be mnully drined. Check the pressure differentil indictor on ll prefilters nd fterfilters. If the differentil pressure is uncceptble, replce the elements. 9. SCHEDULED MAINTENANCE MONTHS Replce purge muffler element Replce the control ir filter element -60 MONTHS The desiccnt in the towers should be replced every two to five yers. The life of the desiccnt will vry depending on the inlet ir conditions. Systems with excessive contminnts nd/or indequte filtrtion will decrese the life spn of the desiccnt drsticlly. Once the desiccnt is contminted with lubricnts, it must be replced. 9.3 DESICCANT REPLACEMENT DO NOT ATTEMPT TO REMOVE ANY ITEM UNTIL ALL AIR PRESSURE IS OUT OF THE VESSEL. CHECK ALL TOWER PRESSURE GAUGES, MAKING SURE THAT THEY ARE AT 0 PSIG AND THAT INCOMING PRESSURE HAS BEEN TURNED OFF. ALWAYS WEAR EYE PROTECTION AND GLOVES WHEN HANDLING THE DESICCANT. DUST FROM THE DESICCANT MAY CAUSE EYE AND SKIN IRRITATION. AVOID BREATHING THE DUST AND PROLONGED CONTACT WITH THE SKIN. Remove ny oil, dirt, or scle from the towers nd piping. Do NOT weld, grind or sndblst the vessels. The vessels my be stem clened internlly nd externlly to remove dirt nd oil. CAUTION Mke sure tht the towers re clen to prevent contmintion of new desiccnt. Reinstll the bushing/diffusers in the bottom of the vessels. Instll the inlet piping ssembly. Apply pipe thred selnt s necessry. Remove the bushing/diffusers from the top of the vessels. Lod desiccnt through these ports. REFER TO SECTION 3. FOR PROPER DESICCANT AMOUNTS. Reinstll the bushing/diffusers in the top of the vessels. Instll the outlet piping ssembly. Reconnect the dryer to the process piping. Apply pipe thred selnt s necessry. Follow START UP PROCEDURES IN SECTION 5. to strt up nd plce dryer in opertion. For HLS-0 nd HLS-50 fill nd drin ports re provided, so piping disssembly is not required. 9. CONTROL AIR FILTER REPLACEMENT Close the dryer inlet nd outlet isoltion vlves (nd open bypss vlve if provided). Turn off the power nd completely depressurize the dryer. DO NOT REMOVE THE FILTER BOWL FROM HEAD UNTIL HOUSING IS COMPLETELY DEPRESSURIZED. After ll pressure is out of the dryer, grsp the filter bowl firmly. While pushing the bowl upwrd, turn it clockwise to remove it from the filter hed. Unthred the used element from the hed. Discrd the used element properly. FIRST AID IN CASE OF EYE CONTACT, IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 5 MINUTES. CONSULT A PHYSICIAN. Tke dryer off strem following the SHUTDOWN PROCEDURES IN SECTION 8. For nd : Crefully disconnect the inlet nd outlet piping ssemblies from the dryer nd process piping. Disconnect the piping ssemblies t the union connections. Unthred the bushing/diffusers from the bottom of ech vessel to drin the old desiccnt. Remove new element from the shipping pckge. Thred the new element into the filter hed. Position the bowl in the filter hed. While pushing the bowl upwrd into the hed, turn the bowl counterclockwise to lock it in plce. Following the strt up procedures for the dryer, plce the dryer on strem. PAGE 8 PRINTED IN THE U.S.A.

9 MAINTENANCE & TROUBLESHOOTING SECTION TROUBLESHOOTING The following check list should be used s guideline for troubleshooting problems. IS THE POWER ON AND RUN SWITCH PRESSED? Check the min power source nd check tht the Power LED is lit. Mke sure tht the dryer Run switch hs been pressed nd tht the Run LED is lit IS THE SYSTEM PRESSURIZED? The dryer is designed to operte t 60 to 50 psig. Check the upstrem equipment nd ny isoltion or bypss vlves. IS THE DRYER CYCLING? IS THE CONTROL SYSTEM WORKING? Is there incoming power to the control box. IS THERE CONTROL AIR PRESSURE, 60 PSIG MINIMUM. Mke sure tht the dryer inlet pressure is bove 60 PSIG. Check the control ir filter element nd replce it with new element. Reference Section 9. for element replcement instructions. IS THE INLET VALVE FAULTY? Rebuild or replce the inlet vlve s necessry. Use mnul override to check. IS THE PURGE EXHAUST VALVE FAULTY? Rebuild or replce the fulty purge exhust vlve. Use mnul override to check. IS THE OUTLET VALVE FAULTY? Check the outlet shuttle vlve. ARE THE TOWERS DEPRESSURIZING? Check the purge vlve for proper opertion. Check the purge muffler. It might be clogged. If clogged or dmged, replce it. Use mnul overide to check. (This should cuse depressuriztion.) IS THE DEW POINT ACCEPTABLE? ARE THE INLET CONDITIONS WITHIN THE SPECIFICATIONS? Reference Section 3. for the inlet conditions of the dryer. Correct the inlet conditions if necessry. Excessive inlet flow will gretly reduce the performnce of the dryer. WAS THE DESICCANT INSTALLED? Mke sure tht the desiccnt ws instlled. Reference Section 9.3 for desiccnt instlltion procedures. IS THE DESICCANT CONTAMINATED WITH LUBRICANTS? Check the condition of the desiccnt bed. If the bed is contminted with lubricnts, replce the desiccnt following the procedures in Section 9.3. IS THE DESICCANT CONTAMINATED WITH MOISTURE? If the dryer ws operted under excessive inlet conditions, the desiccnt bed my be sturted with liquid moisture. Check upstrem equipment such s ftercoolers. Check the ctul inlet conditions, correct them nd condition the bed following the procedures in Section 5.3. ARE THE BYPASS VALVES OPEN OR LEAKING? Check the vlves (if instlled). Repir or replce if fulty. 9.6 WIRING DIAGRAMS CAUTION THE DRYER CONTROL CIRCUIT IS DUAL VOLTAGE RATED. NEVER SET THE BOARD TO A VOLTAGE OTHER THAN THE VOLTAGE RATING OF THE DRYER LISTED ON THE DRYER DATA TAG. SETTING THE BOARD INCORRECTLY WILL CAUSE DAMAGE TO THE INLET AND PURGE VALVES AND POSSIBLE PERSONAL INJURY OR FIRE. PRINTED IN THE U.S.A. PAGE 9

10 REPLACEMENT PARTS SECTION 0 ITEM b c 3 b b c DESCRIPTION Inlet Trnsfer Vlve, -wy Repir kit for -wy vlve Vlve pilot for -wy vlve -wy vlve without bse Outlet Shuttle Vlve Purge Vlve, 3-wy Repir Kit for 3-wy vlve Vlve pilot for 3-wy vlve Pressure Guge Diffuser/Desiccnt Retiner Purge Exhust Muffler Element, purge exhust muffler Control Air Filter Element, control ir filter Desiccnt Activted Alumin, /8" di, 5# pil Control Box (complete) Circuit Bord only Membrne Pnel Pressure Switch (5V) (30V) (5V) (30V) PAGE 0 PRINTED IN THE U.S.A.

11 REPLACEMENT PARTS SECTION 0 ITEM b c 3 b b c DESCRIPTION Inlet Trnsfer Vlve, -wy Repir kit for -wy vlve Vlve pilot for -wy vlve -wy vlve without bse Outlet Shuttle Vlve Purge Vlve, 3-wy Repir Kit for 3-wy vlve Vlve pilot for 3-wy vlve Pressure Guge Diffuser/Desiccnt Retiner Purge Exhust Muffler Element, purge exhust muffler Control Air Filter Element, control ir filter Desiccnt Activted Alumin, /8" di, 5# pil Control Box (complete) Circuit Bord only Membrne Pnel Pressure Switch HLS-0 (5V) HLS-0 (30V) HLS-50 (5V) HLS-50 (30V) PRINTED IN THE U.S.A. PAGE

12 SAFETY PRECAUTIONS Sfety is everybody s business nd is bsed on your use of good common sense. All situtions or circumstnces cnnot lwys be predicted nd covered by estblished rules. Therefore, use your pst experience, wtch out for sfety hzrds nd be cutious. DANGER DANGER DISCHARGE AIR USED FOR BREATHING WILL CAUSE SEVERE INJURY OR DEATH. CONSULT FILTRATION SPECIALIST FOR ADDITIONAL FILTRATIONS AND TREATMENT EQUIPMENT TO MEET HEALTH AND SAFETY REGULATIONS. AIR AND OIL UNDER PRESSURE WILL CAUSE SEVERE PERSONAL INJURY OR DEATH. SHUT DOWN COMPRESSOR AND RELIEVE SYSTEM OF ALL PRESSURE BEFORE REMOVING VALVES, CAPS, PLUGS, FITTINGS, BOLTS AND FILTER. ELECTRICAL SHOCK FROM IMPROPER GROUNDING CAN CAUSE INJURY OR DEATH. GROUND UNIT AND RELATED EQUIPMENT ACCORDING TO NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS. READ THE OPERATOR S MANUAL BEFORE STARTING THIS UNIT. FAILURE TO ADHERE TO INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY OR DEATH. REPLACEMENT MANUALS CAN BE PURCHASHED BY CONTACTING THE MANUFACTURER. PAGE PRINTED IN THE U.S.A.

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000 P.O Box 879 50 W. 6th Ave. - unit P Broomfield, CO 8008 Phone:0-65-06 Order Entry Fax: 0-65-99 www.airdryers.com INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR HEATLESS REGENERATIVE COMPRESSED AIR DRYER

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING January 207 80-572 Rev - 2950 Mechanic Street Lake City, PA 6423 USA Phone: -800-840-9906 Fax: 84-774-0778 Email: info@vanairsystems.com www.vanairsystems.com INSTALLATION, OPERATION & MAINTENANCE MANUAL

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR PREP-40 PORTABLE COMPRESSED AIR DRYER SYSTEM model FR-800 (P/N )

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR PREP-40 PORTABLE COMPRESSED AIR DRYER SYSTEM model FR-800 (P/N ) SEPTEMBER 0 950 Mechanic Street Lake City, PA 643 USA Phone: 800-840-9906 Fax: 84-774-348 www.vanairsystems.com INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR PREP-40 PORTABLE COMPRESSED AIR DRYER SYSTEM

More information

SERVICE DEPARTMENT: (724)

SERVICE DEPARTMENT: (724) 3160824 Rev. 3/05 Internal Use Only 050314 INSTRUCTION MNUL KDW Series: Models 5 through 25 scfm Contents 1.0 GENERL INFORMTION... 1 2.0 DESCRIPTION... 2 3.0 INSTLLTION... 3 4.0 OPERTION... 5 5.0 MINTENNCE...

More information

01672-REVG_071615_ENGLISH

01672-REVG_071615_ENGLISH 01672-REVG_071615_ENGLISH MODEL: CSP CHILLED SERVER WITH PUMP- 1 OUNCE 120V 94060 230V Continentl Europe 94142 CHILLED SERVER WITH PUMP- 2 OUNCE 120V 94050 230V Continentl Europe 94145 230V Austrli 94143

More information

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 500 NORTH OAKWOOD RD LAKE ZURICH, IL,60047 PHONE # (847)

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

24" Built-In Dishwasher. Installation Instructions HDBL655AFS HDBL655AFW HDBL655AFB

24 Built-In Dishwasher. Installation Instructions HDBL655AFS HDBL655AFW HDBL655AFB 24" Built-In Dishwsher Instlltion Instructions HDBL655AFS HDBL655AFW HDBL655AFB TABLE OF CONTENTS DISHWASHER SAFETY... 2 INSTALLATION REQUIREMENTS... 3 Tools nd Prts... 3 Loction Requirements... 5 Product

More information

50 Disassembly and assembly SEN

50 Disassembly and assembly SEN 50 Disssembly nd ssembly SEN01053-01 7. Disconnect filter (5). 8. Disconnect clmp (6). 14. Disconnect rditor lower hoses (13) (15). [*1] 9. Disconnect filter (7). Disconnect the hose clmp. 15. Disconnect

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Heatless Regenerative Air Dryers

Heatless Regenerative Air Dryers Heatless Regenerative Air Dryers CPAD Series / CPADM Series Owner s Manual Jan. 2009 DATE OF PURCHASE MODEL SERIAL NO. Record above information from nameplate. Retain this information for future reference.

More information

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America Heatless Regenerative Compressed Air Dryers Compressed Air System Products Made in America 22 AIR/TAK Heatless Regenerative Air Dryers Compressed Air System Products That Save Energy & Improve Operations.

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

INSTRUCTION MANUAL ENGLISH

INSTRUCTION MANUAL ENGLISH INSTRUCTION MNUL ENGLISH Exhaust / recirculating hood Contents 1 GENERL SFETY GUIDELINES...3 ELECTRICL SFETY...3 PROPER USE...4 ECOLOGICL DISPOSL...4 REFERENCE STNDRDS...4 COMPONENTS...5 DIMENSIONS...6

More information

YZ667A1060. Wireless Domestic Heating Zoning System 1 GENERAL 2 TECHNICAL INFORMATION TABLE OF CONTENTS INSTALLATION GUIDE

YZ667A1060. Wireless Domestic Heating Zoning System 1 GENERAL 2 TECHNICAL INFORMATION TABLE OF CONTENTS INSTALLATION GUIDE YZ667A060 Wireless Domestic Heting Zoning System INSTALLATION GUIDE GENERAL HC60NG Rely Module CM67z Room Unit HR80UK Rditor Controllers TABLE OF CONTENTS Section Pge Generl... Technicl Informtion... 3

More information

Installation and user manual for the integrated washer-dryer machine

Installation and user manual for the integrated washer-dryer machine Instlltion nd user mnul for the integrted wsher-dryer mchine SELECT Built-in Wshing Mchine WDI1200NM wshing mchine contents WARNINGS SPECIFICATIONS INSTALLATION AND ASSEMBLY USING THE APPLIANCE. PRACTICAL

More information

Vertical Dryer Owner s Manual

Vertical Dryer Owner s Manual DSV-250, DSV-450, DSV-750, DSV-1000, DSV-1200 & DSV-1600 Models Model DSV-250 DSV-450 DSV-750 DSV-1000 DSV-1200 DSV-1600 Regulator Setting For Air Motors 22 PSI TO GET 3450 RPM 20 PSI TO GET 1725 RPM 22

More information

DAILY REFERENCE GUIDE

DAILY REFERENCE GUIDE DAILY REFERCE GUIDE THANK YOU FOR BUYING A WHIRLPOOL PRODUCT. In order to receive more complete ssistnce, plese register your pplince on www.whirlpool.eu/register Before using the pplince crefully red

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual MR Series Heatless Mini Regenerative Desiccant Dryer Operator s Manual Introduction Many years of trouble-free service can be expected from your Numatics regenerative dryer. Superior dew point depression

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

HEATLESS REGENERATIVE DRYERS

HEATLESS REGENERATIVE DRYERS HEATLESS REGENERATIVE DRYERS PHL SERIES Pioneer Air Systems Inc. 210, Flatfork Road, Wartburg, TN - 37887 Tel. : (423) 346-6693 Fax : (423) 346-3865, (423) 346-7522 Email : sales@pioneerair.com Internet

More information

DESICCANT DRYER USER MANUAL

DESICCANT DRYER USER MANUAL DESICCANT DRYER USER MANUAL AHLD Series Heatless Regenerative 70-4,000 scfm WARRANTY NOTICE Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its

More information

SSB800 SA SSB1000 SA SSB1000 TL

SSB800 SA SSB1000 SA SSB1000 TL WARNING: If the informtion in these instructions is not followed exctly, fire or explosion my result cusing property dmge, personl injury or deth. Do not store or use gsoline or other flmmble vpors nd

More information

INSTALLER REFERENCE GUIDE

INSTALLER REFERENCE GUIDE INSTALLER REFERENCE GUIDE + ERHQ0BA ERHQ04BA ERHQ06BA ERLQ0CA ERLQ04CA ERLQ06CA EHVH6S8CA EHVH6S6CA EHVX6S8CA EHVX6S6CA Tble of contents Tble of contents About the documenttion. About this document...

More information

WDi2201 Installation and user manual for the integrated washer-dryer machine

WDi2201 Installation and user manual for the integrated washer-dryer machine WDi2201 Instlltion nd user mnul for the integrted wsher-dryer mchine SELECT wshing mchine contents WARNINGS SPECIFICATIONS INSTALLATION AND ASSEMBLY USING THE APPLIANCE. PRACTICAL TIPS MAINTENANCE AND

More information

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Before using this product, read these instructions thoroughly and keep this manual for future reference. AIR CONDITIONER Wll Mounted Type ASTG8KMCA ASTGKMCA ASTGKMCA Before using this product, red these instructions thoroughly nd keep this mnul for future reference. Sfety Precutions R REFRIGERANT This Air

More information

Intruder Alarm Kit IA-210 IA-220 IA-230

Intruder Alarm Kit IA-210 IA-220 IA-230 Intruder Alrm Kit IA-210 IA-220 IA-230 Quick Strt Guide The smrter wy to protect your home. Thnk you for choosing the Yle Intruder Alrm System. This simple to instll system hs been designed with the user

More information

HT/O Outside Humidity and Temperature Sensor

HT/O Outside Humidity and Temperature Sensor Instlltion Instructions Outside Humidity nd Temperture Sensor Importnt: Retin these instructions Contents 1 Unpcking...1 2 Instlltion...1 3 Fult Finding...4 4 Mintennce...5 5 Disposl...8 1 Unpcking Instlltion

More information

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm INSTRUCTION MANUAL DHW Series Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm FORM NO.: 3215738 REVISION: 07/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING

More information

deltaclima CoolWall We provide you with the perfect air-conditioning solution for your computer centre!

deltaclima CoolWall We provide you with the perfect air-conditioning solution for your computer centre! deltclim CoolWll We provide you with the perfect ir-conditioning solution for your computer centre! Weiss Klimtechnik GmbH Pssion for Climte deltclim CoolWll Greter performnce, lower energy consumption,

More information

PIPE LINE DEHYDRATOR FOR NATURAL GAS PLD thru PLD WARNING

PIPE LINE DEHYDRATOR FOR NATURAL GAS PLD thru PLD WARNING INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PN 32-0275 REV A OCTOBER 2003 PIPE LINE DEHYDRATOR FOR NATURAL GAS PLD 8-2.8 thru PLD 36-2.8 WARNING DO NOT REMOVE, REPAIR OR REPLACE ANY ITEM ON THIS

More information

DME DRYER MAINTENANCE MANUAL

DME DRYER MAINTENANCE MANUAL DME DRYER MINTENNCE MNUL DTE : 18February2002 REV: 4 domnick hunter filters limited,durham road, Birtley Co. Durham DH3 2SF, Tel: 091 410 5121 Telex: 537282 Telefax: 091 410 7621 FOREWORD Page 2 of 32

More information

Smoke control dampers

Smoke control dampers X X testregistrierung Smoke control dmpers Type with BLE- ctutor CE complint ccording to Europen regultions For mechnicl smoke extrct systems nd s n dditionl supply ir inlet Rectngulr smoke control dmpers

More information

INSTRUCTIONS FOR INSTALLATION AND USE

INSTRUCTIONS FOR INSTALLATION AND USE INSTRUCTIONS FOR INSTALLATION AND USE SAUNA HEATER 7-0-780 7-45-780 7-60-780 7-80-780 7-90-780 We wish you mny hours of relxtion nd plesure in your sun. Plese red the instructions eneth very crefully in

More information

Equipment Designed for Industrial Applications

Equipment Designed for Industrial Applications Equipment Designed for Industrial Applications Industrial equipment with moving components requires maintenance. As a manufacturer of industrial equipment we strive to produce a product that operates as

More information

This Air Conditioner contains and operates with refrigerant R32.

This Air Conditioner contains and operates with refrigerant R32. AIR CONDITIONER Wll Mounted Type ASTG07CMCA ASTG09CMCA ASTGCMCA Before using this product, red these instructions thoroughly nd keep this mnul for future reference. Sfety Precutions To prevent personl

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

ENCLOSURE AIR CONDITIONERS

ENCLOSURE AIR CONDITIONERS ENCLOSURE IR CONDITIONERS Compact Series 2,000 BTUH Celebrating 20 Years of Excellence Engineered & manufactured to endure the most difficult of environments and applications. ISC air conditioners will

More information

OPERATION MANUAL Split system air conditioners

OPERATION MANUAL Split system air conditioners OPERATION MANUAL Split system ir conditioners FUA71AVEB FUA100AVEB FUA125AVEB CONTENTS 1. SAFETY PRECAUTIONS... 1 2. WHAT TO DO BEFORE OPERATION... 3 3. OPERATION RANGE... 5 4. INSTALLATION SITE... 5 5.

More information

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Before using this product, read these instructions thoroughly and keep this manual for future reference. AIR CONDITIONER Wll Mounted Type Contents Sfety Precutions...En- Indoor Unit Overview nd Opertions...En- Remote Controller Overview nd Opertions...En- Timer Opertion...En- Humn Sensor (Energy Sving)...En-

More information

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Before using this product, read these instructions thoroughly and keep this manual for future reference. AIR CONDITIONER Wll Mounted Type Before using this product, red these instructions thoroughly nd keep this mnul for future reference. Sfety Precutions To prevent personl injury, injury to others, or property

More information

Building Technologies HVAC Products

Building Technologies HVAC Products 7 451 Burner Controls LFL1... Burner controls For gs, oil or dul-fuel forced drft urners of medium to high cpcity For multistge or modulting urners in intermittent opertion With checked ir dmper control

More information

DGH Series Global Air Treatment

DGH Series Global Air Treatment DGH Series Global Air Treatment 2 DGH Desiccant Dryers Customizable Performance Gardner Denver DGH Series Heatless Desiccant Dryers were designed to help you meet your goals. Customizable performance technology

More information

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration INNOVATIVE COMPRESSED AIR SOLUTIONS TM DESICCANT AIR DRYERS 90-8000 scfm ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration www.zeks.com RELIABLE PERFORMANCE. DESIGN INNOVATION.

More information

OPERATING MANUAL. AIR CONDITIONER Wall Mounted Type. Contents. Safety Precautions. Outdoor Unit AOVG09LLCA AOVG12LLCA

OPERATING MANUAL. AIR CONDITIONER Wall Mounted Type. Contents. Safety Precautions. Outdoor Unit AOVG09LLCA AOVG12LLCA Indoor Unit ASVG09LLCA ASVGLLCA Outdoor Unit AOVG09LLCA AOVGLLCA AIR CONDITIONER Wll Mounted Type Contents Sfety Precutions... Indoor Unit Overview nd Opertions... Remote Controller Overview nd Opertions...

More information

Fire dampers. Type FKA-EU. For diverse applications

Fire dampers. Type FKA-EU. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 72 C CE complint ccording to Europen regultions For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between two

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

DESICCANT DRYER USER MANUAL

DESICCANT DRYER USER MANUAL DESICCANT DRYER USER MANUAL ABP Series Blower Purge 800-10,000 scfm WARRANTY NOTICE Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty.

More information

OPERATING MAX FUSE WEIGHT (LBS.) MCA HP FLA RLA LRA COOLING DATA GAS HEATING SECTION ELECTRICAL DATA INPUT SC (MBH) LAT EAT TC (MBH) OUTPUT (MBH)

OPERATING MAX FUSE WEIGHT (LBS.) MCA HP FLA RLA LRA COOLING DATA GAS HEATING SECTION ELECTRICAL DATA INPUT SC (MBH) LAT EAT TC (MBH) OUTPUT (MBH) NEW WTER - SOURCE HET PUMP SCHEDULE TG NO. MKE MODEL RISER SIZE FN DT COOLING DT @ 80/65 HETING DT ELECTRICL DT WTER COND. ESP SPD (20% P.G.) GPM ECH* EWT/LWT TC SC EWT HC VOLTS PH FN COMPRESSOR HP FL

More information

INSTRUCTION MANUAL BUILT-IN OVEN SFA4130VC SFA4130VCB SFA4130VCN SFA4395VCX

INSTRUCTION MANUAL BUILT-IN OVEN SFA4130VC SFA4130VCB SFA4130VCN SFA4395VCX INSTRUCTION MANUAL BUILT-IN OVEN EN SFA4130VC SFA4130VCB SFA4130VCN SFA4395VCX ENGLISH 1 Der customer, we would like to thnk you for your confidence in us. 1 By choosing one of our products, you hve opted

More information

KompaKt. air Handling Units

KompaKt. air Handling Units ir Hndling Units KompKt escription of Komfovent kompkt units 2 KOMPAKT REGO RHP 3 Resons to choose Komfovent kompkt units 4 ontrol System 6 KOMFOVENT KOMPAKT REGO 10 Rotry Het Exchnger 11 Stndrd Sizes

More information

MCFH-A24WV [FLARE CONNECTION TYPE]

MCFH-A24WV [FLARE CONNECTION TYPE] Floor nd Ceiling Type Air-Conditioner MCFH-A24WV [FLARE CONNECTION TYPE] HFC utilized R40A INSTALLATION MANUAL CONTENTS. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 2. SELECTING THE INSTALLATION

More information

Heated Desiccant Air Dryer

Heated Desiccant Air Dryer OWNERS MANUAL F-0073 HEATED DESICCANT AIR DRYER Heated Desiccant Air Dryer MODELS RE231-RE250 ARROW PNEUMATICS Table of Contents Unpacking/Application/Analysis 3 Specifications 4 Dimensional Drawings 5-6

More information

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series Regenerative Desiccant Dryers KAD, KED, KBD and Hybritec Series The Right Dryer For You Most compressed air applications require only refrigerated dryers; however, if your compressed air is exposed to

More information

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series AirCel Heated Regenerative Desiccant Dryers AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed

More information

User reference guide. Daikin room air conditioner FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B. User reference guide Daikin room air conditioner.

User reference guide. Daikin room air conditioner FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B. User reference guide Daikin room air conditioner. FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B English Tble of contents Tble of contents 1 Generl sfety precutions 2 1.1 About the documenttion... 2 1.1.1 Mening of wrnings nd symbols... 2 1.2 For the user... 2 2

More information

OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO

OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO EEV internl model ASYA004GTAH/ASHA004GTAH ASYA007GTAH/ASHA007GTAH ASYA009GTAH/ASHA009GTAH EEV externl model ASYE004GTAH/ASHE004GTAH ASYE007GTAH/ASHE007GTAH ASYE009GTAH/ASHE009GTAH OPERATING MANUAL INDOOR

More information

Quality Components as a basis for Quality Equipment

Quality Components as a basis for Quality Equipment Above & Beyond Regenerative Type Compressed Air Dryers SPS - Heatless Regenerative Dryers SPEH - External Heated Regenerative Dryers SPBS - Heated Blower Purge Regenerative Dryers Quality Components as

More information

MCFZ-A18WV MCFZ-A24WV [FLARE CONNECTION TYPE]

MCFZ-A18WV MCFZ-A24WV [FLARE CONNECTION TYPE] Floor nd Ceiling Type Air-Conditioner MCFZ-A8WV MCFZ-A24WV [FLARE CONNECTION TYPE] HFC utilized R40A INSTALLATION MANUAL CONTENTS. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 2. SELECTING THE

More information

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm CDT Series Heatless Desiccant Air Dryers 40 5,400 SCfm ISO Quality Dew Points Three Controller Selection NEMA4 Electrical Construction Standard on Two Controllers Purge Optimal Savings 2 Personalized Performance

More information

SSB85 SSB120 SSB160. Gas Condensing Stainless Steel Boiler BUDERUS SSB BOILER. Installation and Service Instructions for Contractors

SSB85 SSB120 SSB160. Gas Condensing Stainless Steel Boiler BUDERUS SSB BOILER. Installation and Service Instructions for Contractors WARNING: Improper instlltion, set-up, modifiction, opertion or mintennce of the heting system cn cuse personl injury nd property dmge. Follow these instructions precisely. If you require ssistnce or further

More information

Owner s Manual. Instant Hot Water Dispenser. Installation, Care & Use H-SH10-SS REV A. Pat. hppt://www.isepat.com

Owner s Manual. Instant Hot Water Dispenser. Installation, Care & Use H-SH10-SS REV A. Pat. hppt://www.isepat.com Instnt Hot Wter Dispenser Owner s Mnul Instlltion, Cre & Use Pt. hppt://www.isept.com Stemin Hot is registered trdemrk of Emerson Electric Co. AnswerLine is trdemrk of Emerson Electric Co. 44891 REV A

More information

Owner s Manual. Instant Hot Water Dispenser. Installation, Care & Use E340-SS REV A

Owner s Manual. Instant Hot Water Dispenser. Installation, Care & Use E340-SS REV A Instnt Hot Wter Dispenser Owner s Mnul Instlltion, Cre & Use Stemin Hot is registered trdemrk of Emerson Electric Co. AnswerLine is trdemrk of Emerson Electric Co. 4467 REV A The Emerson logo is trdemrk

More information

Fire dampers. Type FKA-3.8. For diverse applications

Fire dampers. Type FKA-3.8. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 7 C or 95 C For diverse pplictions Rectngulr fire dmper for the isoltion of duct penetrtions between fire comprtments, for mortr-bsed instlltion

More information

NEWGATE TECHNOLOGIES, INC.

NEWGATE TECHNOLOGIES, INC. www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety

More information

70XXA-1 series. Voltage. Features. Applications. Description. Order Information. Designator Symbol Description 1 2 Integer Output Voltage(2.2~7.

70XXA-1 series. Voltage. Features. Applications. Description. Order Information. Designator Symbol Description 1 2 Integer Output Voltage(2.2~7. Fetures Low power consumption Low temperture coefficient Builtin hysteresis chrcteristic High input voltge (up to 24) Output voltge ccurcy: tolernce ±2% TO92, SOT89 nd SOT23 pckge Applictions Bttery checkers

More information

Installation, Operation, and Maintenance Instructions. Heatless Regenerative Air Dryers and HLD-PAK Dryer/Filter Packages HLD-25 through HLD-6250

Installation, Operation, and Maintenance Instructions. Heatless Regenerative Air Dryers and HLD-PAK Dryer/Filter Packages HLD-25 through HLD-6250 107 W. Main Street, Worthington, PA 16262 Phone: 724-297-3416 Fax: 724-297-5189 URL: http://www.airtak.com e-mail: airtak@airtak.com Installation, Operation, and Maintenance Instructions Heatless Regenerative

More information

Use. Mechanical design

Use. Mechanical design 7 451 ISO9001 Gs Burner Controls LFL1... Supplementry dt sheet 7712 Gs urner controls for gs, oil or dul-fuel forced drught urners of medium to high cpcity. ultistge or modulting urners in intermittent

More information

MCFZ-A12WV MUZ-A12YV(H) [FLARE CONNECTION TYPE]

MCFZ-A12WV MUZ-A12YV(H) [FLARE CONNECTION TYPE] Floor nd Ceiling Type Air-Conditioner MCFZ-A2WV MUZ-A2YV(H) [FLARE CONNECTION TYPE] HFC utilized R40A INSTALLATION MANUAL CONTENTS. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 2. SELECTING

More information

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual Manual P568800 Rev 1, Mar 30, 2010 1 As the installer or operator, you should make yourself familiar with this Installation and

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

Fire dampers. Type FK-EU. For diverse applications

Fire dampers. Type FK-EU. For diverse applications . X X testregistrierung Type with fusible link for 72 C or 95 C CE complint ccording to Europen regultions With TROXNETCOM s n option ATEX certifiction For diverse pplictions Rectngulr fire dmper for the

More information

Overview of HL series heatless regenerative dryers.

Overview of HL series heatless regenerative dryers. Overview of HL series heatless regenerative dryers. WWW.VANAIRSYSTEMS.COM Billbert www.vanairsystems.com Regenerative Desiccant Dryers MHL/HLS Series Heatless HL Series Heatless HI Series-Heated Internally

More information

Building Technologies Division

Building Technologies Division 7 451 Burner Controls LFL1... Burner controls For gs, oil or dul-fuel forced drft urners of medium to high cpcity For multistge or modulting urners in intermittent opertion With checked ir dmper control

More information

CDH Series Heatless Desiccant Dryers CFM

CDH Series Heatless Desiccant Dryers CFM CDH Series Heatless Desiccant Dryers 0 500 CFM NEW Engineered to Save CDH Desiccant Dryers Customizable Performance CompAir CDH Series Heatless Desiccant Dryers were designed to help you meet your goals.

More information

CORDLESS POLE HEDGE TRIMMER INSTRUCTION MANUAL

CORDLESS POLE HEDGE TRIMMER INSTRUCTION MANUAL WHAT S IN THE BOX Pole Hedge Trimmer Hed CORDLESS POLE HEDGE TRIMMER INSTRUCTION MANUAL SPECIFICATIONS Input: 18V Cutting Length: 400mm Mx. Cutting Cpcity: 12mm No Lod Speed: 1,700/min Length: 2.10 3.04m

More information

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series Desiccant Air Drying Technologies HCS Series HCL Series HCT Series HCS, HCL and HCT Series Heatless Dryers Models 40-450 Models 590-5400 HCS, HCL and HCT Series Heatless Desiccant Dryers Since 1961, compressed

More information

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS INGERSOLLrAND AIR COMPRESSORS HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS CAUTION: For HMD Models 84 Through 385 ONLY 1. Remove Dryer Chambers And Protective

More information

COTES ALL-ROUND THE C35 RANGE

COTES ALL-ROUND THE C35 RANGE EPERTS IN HUMIDITY MNGEMENT COTES.COM DEHUMIDIFICTION THE WY YOU WNT IT C35 DEHUMIDIFIER IDEL FOR USE IN > PHRMCEUTICL PRODUCTION FCILITIES > FOOD INDUSTRY PROCESSING FCILITIES > COLD STORES/FREEZER FCILITIES

More information

DESICCANT DRYER USER MANUAL

DESICCANT DRYER USER MANUAL DESICCANT DRYER USER MANUAL AEHD Series Externally Heated 150-3,000 scfm WARRANTY NOTICE Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty.

More information

10/09/2014. SFD Air Dryer Owner s Manual

10/09/2014. SFD Air Dryer Owner s Manual 10/09/2014 SFD Air Dryer Owner s Manual Table of Contents WARNING Read, understand and follow safety precautions and instructions in this manual and in the labels attached to the dryer system. Failure

More information

Desiccant Air Dryers. Heatless, Heated and Heated Blower

Desiccant Air Dryers. Heatless, Heated and Heated Blower Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... When we designed the Ingersoll Rand heatless, heated and heated blower desiccant dryers we set our sights on creating the most

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air is damaging.

More information

HEATLESS DESICCANT AIR DRYERS

HEATLESS DESICCANT AIR DRYERS HEATLESS DESICCANT AIR DRYERS HHS, HHL AND HHE SERIES HANKISON HEATLESS DESICCANT DRYERS HHS, HHL AND HHE SERIES Since 1948, sensitive applications requiring clean, dry, compressed air have turned to Hankison

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Understanding Compressed Air Moisture

More information

ADDENDUM #1. T Fire Alarm Replacement St. Mark Elementary and BAS Replacement St. Bernadette Elementary

ADDENDUM #1. T Fire Alarm Replacement St. Mark Elementary and BAS Replacement St. Bernadette Elementary Dufferin-Peel Ctholic District School Bord 40 Mtheson Boulevrd West, Mississug, ON, L5R 1C5, Tel: (905) 890-1221 June 29, 2017 DDENDUM #1 T81-2017 Fire lrm Replcement St. Mrk Elementry nd BS Replcement

More information

Owners Manual Refrigerated Air Dryer MHT SERIES

Owners Manual Refrigerated Air Dryer MHT SERIES Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION

More information

SSB255 SSB399 SSB512. Gas Condensing Stainless Steel Boiler BUDERUS SSB BOILER. Installation and Service Instructions for Contractors

SSB255 SSB399 SSB512. Gas Condensing Stainless Steel Boiler BUDERUS SSB BOILER. Installation and Service Instructions for Contractors WARNING: Improper instlltion, set-up, modifiction, opertion or mintennce of the heting system cn cuse personl injury nd property dmge. Follow these instructions precisely. If you require ssistnce or further

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

MOBILE LAB UNITS 4111, 4121, 4222, 4342, 4332, 4352, 4101, 4401, 4751, 4901, 5201, 4741, 4701, 5301 SERIES (OAK OR MAPLE) ASSEMBLY INSTRUCTIONS

MOBILE LAB UNITS 4111, 4121, 4222, 4342, 4332, 4352, 4101, 4401, 4751, 4901, 5201, 4741, 4701, 5301 SERIES (OAK OR MAPLE) ASSEMBLY INSTRUCTIONS 4111, 4121, 4222, 4342, 4332, 4352, 4101, 4401, 4751, 4901, 5201, 4741, 4701, 5301 SERIES (OK OR MPLE) 1. MODEL VIEWS MY NOT REPRESENT EXCT MODEL PURCHSED : : CRETED NME THIS DRWING IS THE SOLE PROPERTY

More information

HOT WATER SYSTEMS. thermann.com.au

HOT WATER SYSTEMS. thermann.com.au HOT WTER SYSTEMS thermann.com.au 2 HOT WTER YOU CN DEPEND ON Precision engineered for efficiency and long life, Thermann is setting new standards for hot water systems in ustralia. Packed with innovative

More information

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series Heat Les Desiccant Compressed Air Dryers DSE Series DSS Series DHD Series DSE, DSS and DHD Series Heat Les Desiccant Dryers For decades, compressed air users have relied on Pneumatic Products to deliver

More information

Lift-Away XL UV550. Series INSTRUCTIONS. sharkclean.com

Lift-Away XL UV550. Series INSTRUCTIONS. sharkclean.com Lift-Awy XL UV550 Series INSTRUCTIONS shrkclen.com IMPORTANT SAFETY INSTRUCTIONS HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE To reduce the risk of electric shock, this vcuum

More information

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of

More information

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer Adsorption dryer Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE Regenerative Type Heatless Desiccant Dryer WE REDEFINE COMPRESSED AIR TREATMENT SYSTEMS 5/232 KNG Pudur road, Somayampalayam

More information

WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY

WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY CHAPTER 6 WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY SECTION 601 (IgCC 701) GENERAL 601.1 (IgCC 701.1) Scope. The provisions of this chpter shll estblish the mens of conserving wter, protecting

More information

Fire dampers. Type FK-EU. For diverse applications

Fire dampers. Type FK-EU. For diverse applications . X X testregistrierung Fire dmpers Type with fusible link for 72 C or 95 C CE complint ccording to Europen regultions With TROXNETCOM s n option ATEX certifiction For diverse pplictions Rectngulr fire

More information

407C Heating Hydraulic module Use AQUACIATCALEO AQUACIATCALEO AQUACIATCALEO Range AQUACIATCALEO TD series

407C Heating Hydraulic module Use AQUACIATCALEO AQUACIATCALEO AQUACIATCALEO Range AQUACIATCALEO TD series Het pump Compct nd silent Optimised for heting High energy efficiency Winter opertion down to -20 C Hot wter production up to +65 C Heting cpcity: 20 to 101 kw 407C Heting Hydrulic module Use The new genertion

More information

Performance evaluation of displacement ventilation system combined with a novel evaporative cooled ceiling for a typical office in the city of Beirut

Performance evaluation of displacement ventilation system combined with a novel evaporative cooled ceiling for a typical office in the city of Beirut Avilble online t www.sciencedirect.com ScienceDirect Energy Procedi 75 (2015 ) 1728 1733 The 7 th Interntionl Conference on Applied Energy ICAE2015 Performnce evlution of displcement ventiltion system

More information