1 University of Wisconsin-Stevens Point REQUEST FOR ARCHITECTURAL & ENGINEERING DESIGN SERVICES NEALE RESIDENCE HALL RENOVATION PROJECT January 2009 DSF Project # 09L2E

2 TABLE OF CONTENTS PAGE Project Scope & Description 3 Project Budget 4 Project Schedule 4 University of Wisconsin Contacts 4 Websites 4 General Requirements 5 Site and Utilities 5 Architectural 6 Heating Venting & Air Conditioning 6 Electrical 7 Health & Safety 8 User Description of Functions & Requirements 8 Resident Rooms 8 Common Areas 9 Hall Director Apartment 9 Appendix Neale Standard Resident Room Floor Plan 10 Neale Resident Room-Former Lounge Room Floor Plan 11 Neale Basement Floor Plan 12 Neale 1 st Floor Plan 13 Neale 2 nd, 3 rd & 4 th Floors Floor Plan 14 Campus Map 15 2

3 Project Scope and Description This project will renovate Neale Residence Hall in the south DeBot quadrant at UW-Stevens Point. The project will roughly duplicate similar renovation work completed on two separate residence halls in summer 2008 and 2009 and a third residence hall beginning construction on May 24, An added expectation for this renovation will be an attempt to achieve recognition for sustainable features as a LEED Existing Building. The consulting A-E team will provide complete documentation, prerequisites, commissioning oversight and application materials necessary for current LEED Existing Building: Operations & Maintenance rating certification. The team will provide the user agency with documented recommendations and goals to help the campus maintain efficient and clean performance for future LEED EB O&M recertification. Neale hall comprises a total of 53,917 GSF and 270 total beds, and will receive significant renovations with room lighting upgrades, updates to all closet side panels, replacement of existing resident room slide-by windows, and replacement of resident room and lower level wood doors with new wood doors. The steam radiant heat system will be replaced with a four pipe system that will incorporate hot water and future air conditioning and will allow for individual room control within a pre-set range. The existing instantaneous hot-water conversion unit will be modified to include tank storage similar to the Steiner Hall 2009 installation. ADA modifications shall include: a) removal of bathtubs in private baths on floors 2-4 to accommodate shower areas for wheelchair restricted residents/guests on all floors, b) lower-level gender specific toilet rooms to be made fully accessible and converted to be nongender specific, c) a 5-stop elevator installed, d) an exterior ramp to the lobby level, and e) resident and public access rooms door handle hardware upgraded to a graspable lever style. Eleven resident rooms on various floors will be made fully ADA accessible. A fire sprinkler system will be installed throughout. Masonry block walls in resident rooms and resident floor corridors will receive a thin-coat plaster finish and paint. All resident room ceilings to be re-painted and the floor corridor ceilings will have the tectum removed and the surface painted. Carpeting in the resident rooms, main corridors, front lobby and all lower level rooms will be replaced. The door into the Hall Director s apartment will be replaced with a 36-inch wide door for wheelchair access.. The HD apartment will be provided with a private 36-inch wide exterior entrance and small patio. Existing telephone and data connections will be relocated to new exterior wall panels. The fire alarm system will be upgraded to current standards of addressable devices, synchronized strobes and emergency broadcasting capabilities. The building emergency lighting and power circuits will be connected to an electrical generator installed in Steiner Hall in The campus presently manages twelve four story residence halls with beds for approximately 3000 students with a GSF of just over 672,000. These residential buildings are of a traditional style with double loaded corridors and centrally located group bathroom facilities on each floor built primarily in the 1960's. A renovation of similar scope took place in Baldwin hall in 2008, Steiner Hall 2009, and Hansen hall beginning in May Baldwin, Steiner and Hansen halls are neighboring halls located west and north of Neale in hall in the South DeBot quadrant. Baldwin, Steiner and Hansen are of same building structure and bed capacity as Neale hall. Neale hall received a major renovation in 1994 which concentrated primarily on common areas such as the bathrooms where gang showers were converted to private shower stalls and worn restroom fixtures were replaced. Recycling chutes were added and kitchenettes installed on each floor. Voice and data wiring was updated to Category 5E. All fire alarm systems were upgraded but do not provide the current standard of addressable devices, synchronized strobes, or emergency voice broadcast capability. 3

4 The renovations should comply with DSF Sustainability Standards, Act 141 and Executive Order 145 issued in April EO 145 relates to conserving Wisconsin and the creation of high performance green building standards and the energy conservation for state facilities and operations based on the LEED Green building Rating System for existing buildings. Project Budget Construction $4,168,000 Contingency (7%) 272,000 A/E Design & other fees (8.1%) 334,600 LEED EB Certification Costs 20,000 DSF Management (4%) 178,900 Percent for Art 12,500 Total $4,986,000 Project Schedule A/E Selection February 2010 Design Report Completion August 2010 BOR/SBC Authority to Construct September % Documents Submitted for Review December 2010 Bid Opening February 2011 Start Construction May 2011 Substantial Completion August 2011 Occupancy September 2011 Final Completion November 2011 University of Wisconsin Contacts Title Name Phone Number Address Agency Representative UW-System Administration Maura Donnelly mdonnelly@uwsa.edu Campus Representative UWSP Dir. Facilities Planning Carl Rasmussen crasmuss@uwsp.edu Pertinent Websites UW-Stevens Point UW-Stevens Point Residential Living UW System Capital Planning & Budget City of Stevens Point Wis. Division of State Facilities

5 General Requirements Site and Utilities Soil Conditions Four soil borings were done as part of the original Neale hall construction in 1965 and are available on page 2 of project drawings for project # Cross section results generally show very dense red and gray granite at an elevation ten to sixteen feet below surface covered by varying levels of medium to coarse firm brown sand, topped by a two feet of loose medium sand and then, six inches of organic topsoil. The soil borings generally showed ground water at one to two feet above the dense red and gray granite. Zoning Requirements University of Wisconsin facility projects are required to conform with local zoning. There is nothing in the proposed project which will trigger the need for a zoning review. WEPA To comply with the Wisconsin Environmental Policy Act (WEPA) a Type III Environmental Action is required. This is a campus responsibility and will not necessitate any action on the part of the A/E team. City Water The Stevens Point Water Department supplies Buildings and an outdoor system with domestic water at a pressure of 65 lb. Underground piping is cast iron with all services adequate and in good repair. An 8-inch lateral with a 3-inch meter currently services the building and enters from the West side. The A/E team will need to analyze the requirements for sprinklering thus upgrades may be needed. An 8- inch city water main runs parallel to Isadore Street the building approximately 330 feet away. The need for an upgrade to capacity needs to be verified by the A/E team. Primary Electric The campus primary electric and signal underground conduit system runs parallel to and just to the east of the Isadore Street right of way boundary. This conduit duct bank installed in 1965 contains (10) 4 PVC conduits encased in a concrete envelope. Four of these conduits are dedicated to the primary power delivery system. Two of these conduits contain 15KV feeder cables sized at 1/0 and 4/0. The building appears to have adequate capacity to add the elevator component to the project, however the A/E team will need to verify. An emergency generator was installed as part of the Steiner Hall renovation project (08C2W) in 2009 with the capacity to serve Neale Hall. Switching will occur through the immediately adjacent Baldwin Hall. Signal Six of the ten conduits in the campus duct bank are dedicated to signal system delivery. These conduits contain four 32-strand and one 16-strand fiber optic data cables installed in 1993 along with multi-pair telephone and other low voltage cables. This signal conduit system is of adequate capacity to carry any additional signal conductors required to support additional space. 5

6 Architectural The addition of the elevator core and the new entry ramp must fit within the context of the existing building. Building Envelope The building envelope is basically secure and in good repair. Bricks show no need for tuck-pointing, expansion joints are caulked, doors, windows, and frames are solid and roof access assemblies and penetrations are functional and holding. ADA The residence halls are not compliant with current ADA requirements. A complete ADA analysis is required for the project. The current entrance to the building is by way of ramp with a gradient that exceeds ADA requirements. Upon entering the building, only the first floor is accessible to any wheelchair bound occupants or guests. Occupancy During Construction The building will be vacant during the 2011 summer break to allow construction work in the entire facility. Heating, Venting and Air-Conditioning The intention of this upgrade is to replace steam heating system and controls with a new hot water heating system 4 pipe system that can provide air conditioning when connected to a future source of chilled water which should be available in summer Existing make-up air and toilet exhaust systems were installed in Building steam service, pressure reducing station, and condensate return pumps are in good condition. Since they were installed the make-up air units have had chronic problems with coil freezing and low temperature shut downs. This problem should be addressed by the project. Campus Automation System The campus automation system is a Johnson Controls Metasys Extended Architecture Network. All new controls should be DDC and should be served and monitored by the campus system through the existing building network connection. Resident rooms shall have independent control within a pre-set range. Plumbing Domestic Plumbing Systems The 1994 renovation of the bathrooms included providing private shower stalls replacing bathroom fixtures and plumbing systems. Four years ago following a leak in the bulk hot water storage tank, the tank was removed and an instantaneous steam water heater was installed. When combined with other instantaneous heaters in the residential halls, these heaters have been targeted for causing consumption demand spikes for steam from the central heating plant. This project will modify the existing instantaneous steam water heater to include a holding and blending tank configured similar to the instantaneous water heater and tank installed in adjacent Steiner Hall in

7 Fire Protection System The entire building should be served by a wet sprinkler system with concealed piping to the greatest extent possible. Piping must be concealed in common areas. Each floor should be provided with individual control valves. Vandal proof (security type) heads should be used on resident floors. Sprinkler heads in the lower level common areas will be protected with sprinkler head guards. A stand pipe will be added to the common stairways. No fire pump is required. Electrical Transformer Rating Transformer rating is 1000 KVA. Telecommunications The telecommunications system was updated in all residence halls during the summer months of Two 5e data jacks were installed on each side of the side of the room for internet capabilities of each resident. These jacks will be relocated to the new exterior wall panel. This will involve pulling existing cabling back to the lower-level, core drilling the floors, and re-pulling and terminating the wiring in the wall panel. Lower-level wiring will be routed via cable-tray. Fire Alarm Central Reporting A centralized, smoke detector and fire alarm system, as manufactured by Simplex, Model 4002 was installed as part of a comprehensive campus project in 1995, DSF Project 93A79. This project provided solid state electronic zoned display panels with voice evacuation capability. It is operated with low voltage cable and includes smoke detectors, pull stations, speaker/strobes and strobe annunciating devices. The system reports events to the campus security department located in the George Stein Building. The existing control panel will be upgraded to accept addressable devices and initiating devices (i.e. smoke/heat detectors, pull stations) and perform Emergency Broadcasting from University Protective Services such that Protective Services can address one hall or all halls in case of emergency. Strobes will be replaced with synchronized strobes. The new sprinkler system to include flow and tamper switch alarms integrated into the alarm system. Public Address System The front desk is equipped with a PA system that allows for communication to all floors. A speaker box is located in each wing for communication from the main PA system located behind front desk. No work will be done to the PA system. Health and Safety Asbestos Wisconsin Asbestos and Lead Abatement Management System identify residence hall areas as asbestos free with the exception of fire doors. To the best of Residential Living knowledge and ability all accessible ACM floor tile, mastic and pipe elbows were abated during the 1994 bathroom renovation upgrade. According to the WALMS report last revision 4/24/2003 asbestos containing 12x12 white and brown floor tiles with mastic exists in 002, 016, 031, 034 and 038. Asbestos containing carpet mastic exists in 002, 003, 004, 005, 016, 021 and 030. Since the revision of 4/24/2004 Residential Living has removed all ACM fire doors in Neale Hall. Lead The campus is not aware of any exposed lead containing products within the residence halls. 7

8 User Description of Functions & Requirements Resident Rooms Occupants 2/room 160 ASF/room Total Rooms 135 A). Activity The resident rooms are fundamentally used as sleeping accommodations for 2 residents of primarily freshman or sophomore age. The secondary function of a resident room is as a small living environment which is conducive to studying and reading. The rooms are furnished with 2 beds, 2 desks with attached lighted hutch and a 5 drawer dresser set under a wall mount 24 x 27 mirror. There are 2 mirror fixtures installed above each mirror that are currently in excess of 30 years old and require a great deal of repeated repair, replacements and modifications. The rooms are equipped with 2 telecommunication ports one on each side of the room along with duplex outlets located slightly above the dresser tops on each side of the room along with quad plexes at the back of the room behind the desks. Residents are able to bring in lofts and/or bunks to suit their preferred room arrangement along with additional personal furnishings including, but not limited to soft seating, microwaves, refrigerators, floor and table lamps, entertainment centers and etc. Residents are able to configure and arrange their rooms as necessary during their stay. B.) Special Equipment or Services Lighting Inadequate lighting remains to be an issue within the resident rooms. Residents request more lighting and more versatile lighting options to suit their living style. Install new over-the-mirror fixtures (2 per room) Install a ceiling mount fixture in each room Unify switching to door frame for mirror and ceiling fixtures Energy efficient fluorescent only Housing and lens to be durable for a high use environment Aesthetic value of housing/casing to have residential appeal Ease of maintenance and/or lamp replacement by one facility repair worker Electronic ballasts 20 year life expectancy for housing Thin-coat block walls Concrete block is to be thin coated to provide a flush residential wall finish. All existing ceiling tectum panels are to be removed with ceiling thin coated and painted. Slight texture Painted surface Door Knobs All resident room door handles are to be replaced with lever style handles to make rooms more accessible and user friendly. Locks must be compatible with current lock systems Doors Due to maintenance issues with existing doors, all resident room and existing wood public access room doors are to be replaced with new wood doors. 8

9 Windows Replacement of resident room windows will aid in more efficient temperature control of each resident room. 3 Panel glazing Outside slider panels Screens Common Areas A). Activity The common areas include all corridors T-Centers, public use rooms in lower level, lobby, and study lounge and floor kitchens. These spaces are a vital element of the residence hall as they encourage and promote community and programming efforts within the hall. The room sizes, use and finish vary to meet the needs of the residents and staff. All spaces are identified as high use that requires maintenance friendly, durable and aesthetically pleasing finishes. Thin-coat block walls & ceilings Concrete block is to be thin coated to provide a flush residential wall finish. All existing ceiling tectum panels are to be removed with ceiling thin coated and painted. Slight texture Painted surface Door Knobs All public access door handles are to be replaced with lever style handles to make rooms more accessible and user friendly. Locks must be compatible with current lock systems Doors Due to maintenance issues with existing doors, all resident room and existing wood public access room doors are to be replaced with new fire rated wood doors. Elevator In addition to use as a personal transport the elevator will also be utilized for delivering materials, supplies, furnishings and/or heavy equipment between the floors. The elevator will serve as a much needed transport of recycling bins between floors by staff. The bins contain broken glass, paper, cardboard and other recyclable material with weights averaging anywhere between lbs each. Elevator to have 5 stops Finish to match or coordinate with exterior brick 6 8 person; 4500 lb capacity Bathrooms: Toilet rooms on the lower level to be made ADA compliant and non-gender specific for purposes of providing an accessible toilet room on all floors. Hall Director Apartment Secondary Entrance & Patio: A secondary private apartment entrance with patio is to be added to the building exterior at the Hall Director Living room location. The entrance and patio are to coordinate with the building envelope and are to provide the Hall Director with privacy, security and adequate space for outdoor leisure. 9

10 NEALE STANDARD RESIDENT ROOM 10

11 NEALE FORMER LOUNGE RESIDENT ROOM 11

12 NEALE BASEMENT PLAN Please Note: Dimensions provided are close approximations and are not to be considered as exact measurements. Ceiling Height: 7-9 approx. 12

13 NEALE FIRST FLOOR PLAN Plan not to scale. Ceiling Height: 7-9 approx. 13

14 NEALE 2 4 FLOOR PLAN Plan not to scale. Ceiling Height: 7-9 approx. 14

15 NEALE UW-SP Campus Map 15

UNIVERSITY OF WISCONSIN-PLATTEVILLE REQUEST FOR ARCHITECTURE & ENGINEERING PRE-PLANNING & DESIGN SERVICES. for. Williams Fieldhouse - Phase I

UNIVERSITY OF WISCONSIN-PLATTEVILLE REQUEST FOR ARCHITECTURE & ENGINEERING PRE-PLANNING & DESIGN SERVICES. for. Williams Fieldhouse - Phase I UNIVERSITY OF WISCONSIN-PLATTEVILLE REQUEST FOR ARCHITECTURE & ENGINEERING PRE-PLANNING & DESIGN SERVICES for Williams Fieldhouse - Phase I 2007-2009 August 2007 DSF # 07E2H TABLE OF CONTENTS Scope of

More information

Appendix B. Facilities Assessment Report

Appendix B. Facilities Assessment Report Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates

More information

PLATTEVILLE MIDDLE SCHOOL

PLATTEVILLE MIDDLE SCHOOL Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle

More information

MEETING NOTICE BOARD OF REGENTS OF THE UNIVERSITY OF WISCONSIN SYSTEM EXECUTIVE COMMITTEE

MEETING NOTICE BOARD OF REGENTS OF THE UNIVERSITY OF WISCONSIN SYSTEM EXECUTIVE COMMITTEE MEETING NOTICE BOARD OF REGENTS OF THE UNIVERSITY OF WISCONSIN SYSTEM EXECUTIVE COMMITTEE Friday, July 27, 2018 8:00 a.m. To be held by telephone conference 1511 Van Hise Hall 1220 Linden Drive Madison,

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 No. Discipline Sent to Name Item Date Noted Date Resolved How item was resolved SCO # 1Punch listed items were noted below on

More information

Binghamton University Construction SUMMER 2012 HIGHLIGHTS

Binghamton University Construction SUMMER 2012 HIGHLIGHTS Binghamton University Construction SUMMER 2012 HIGHLIGHTS Binghamton University Construction Summer 2012 Large and small construction projects were completed during the summer 2012 construction season.

More information

Garfield Elementary School Feasibility Study for New Library Building Project Number A C

Garfield Elementary School Feasibility Study for New Library Building Project Number A C Larry Teixeira Selma Unified School District 3036 Thompson Avenue Selma, CA 93662 Subject: Feasibility Study for New Library Building Project Number A 12-8581.00 C Dear Mr. Teixeira: At your request, we

More information

DMTF: Specific Building Recommendations

DMTF: Specific Building Recommendations DMTF: Specific Building Recommendations Asset Name Project Title Total Cost BLOCKER BUILDING 22,503,303 Capital Renewal 7,640,013 DOMESTIC WATER HEATER REPLACEMENT 16,374 EXTERIOR DOOR REPLACEMENT 133,623

More information

S AGE E NGINEERING A SSOCIATES, LLP

S AGE E NGINEERING A SSOCIATES, LLP S AGE E NGINEERING A SSOCIATES, LLP 1211 Western Avenue Albany, NY (518) 453 6091 F (518) 453 6092 Kingston Library Mechanical and Electrical Systems Field Report Date of Visits: Mechanical - September

More information

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED Ashton Elementary School 1 Masonry Repair $ 42,781.50 2 Replace HVAC $ 375,000.00 3 Replace SAT @ Various Locations $ 92,364.00 3 Recoat & Resurface Exterior Paved Play Area $ 135,978.30 3 Various Technological

More information

Maintenance Road Show

Maintenance Road Show Maintenance Road Show What does it take to maintain a campus? What are the costs? Buildings: 267 Campus Sq. Feet: 3,470,408 GSF Roads: 8.28 miles Walkways: 8.81 miles Exterior lights: 1,000 Exterior stairways:

More information

DAMAGE CODES* CODE DAMAGE COST

DAMAGE CODES* CODE DAMAGE COST 2017-2018 DAMAGE CODES* CODE DAMAGE COST # CODE 100 DOORS 100 DOORS 101 DOOR JAMB REPAIR/REPLACEMENT 250 200 KEYS 102 DOOR KNOB SET REPLACEMENT (APTS) 120 300 WINDOWS 103 DOOR KNOB SET REPLACEMENT (RH)

More information

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc.

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc. Memphis Housing Authority High Rise Fire Alarm Upgrades Questions from Contractors (Through Addendum #2) Communications Systems, Inc.: Legend 1. DL - Dome light symbol should be on the tenant emergency

More information

Electronic Safety and Security

Electronic Safety and Security 28 Electronic Safety and Security NOTE: This is a new section, which includes content from previous sections of the KU Design Standards, along with appropriate revisions and updates. Significant revisions

More information

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data.

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data. NARRATIVE REPORT 1.0 BUILDING INFORMATION Engineering and Technology was originally constructed in 1913; although specific information is unavailable, several renovations are evident. Engineering and Technology

More information

NARRATIVE REPORT. Engineering Administration was originally constructed in 1965; the building has had no major renovations.

NARRATIVE REPORT. Engineering Administration was originally constructed in 1965; the building has had no major renovations. NARRATIVE REPORT 1.0 BUILDING INFORMATION Engineering Administration was originally constructed in 1965; the building has had no major renovations. Engineering Administration is a three-story, 9,579 ft

More information

University Design Standard Fire Alarm Systems

University Design Standard Fire Alarm Systems 1.0 Overview University Design Standard Fire Alarm Systems This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit

More information

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT State College Area School District High School North Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information Charles M. LeMaistre PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and

More information

Appendix E: Photo Documentation

Appendix E: Photo Documentation Appendix E: Photo Documentation Brown County Library Central Branch Building Assessment Appendix E: Photo Documentation Architectural and Structural Brown County Library Central Branch Building Assessment

More information

PLAN REVIEW SUBMITTAL GUIDE

PLAN REVIEW SUBMITTAL GUIDE PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide

More information

Oconomowoc Area School District Facility Construction Update August 25, 2017

Oconomowoc Area School District Facility Construction Update August 25, 2017 Oconomowoc Area School District Facility Construction Update August 25, 2017 IXONIA ELEMENTARY SCHOOL Ixonia Elementary is getting ready for the start of the new school year! Interior cleaning and classroom

More information

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the

More information

MUKWONAGO SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

MUKWONAGO SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY MUKWONAGO SCHOOL DISTRICT ARCHITECTURE PARK VIEW MIDDLE SCHOOL The original school building was dedicated in 1954 as the High School, with an addition in 1959, a library addition in 1970, and an addition/renovation

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District HOLUM EDUCATION CENTER Architectural The existing building has approximately 41,823 square feet and sets on a lot about 4.14 acres in size. Parking lots are located along the east and west sides of the

More information

Element Z General Design Requirements Existing Facilities Information

Element Z General Design Requirements Existing Facilities Information PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and Element Z for technical

More information

2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16

2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16 1. General: This summary is offered as a supplement to the 2015 Building Condition Survey being filed with SED on behalf of the District. All cost estimates are preliminary, and should be re-evaluated

More information

Norrys Road Cockfosters Barnet EN4 9JX

Norrys Road Cockfosters Barnet EN4 9JX Norrys Road Cockfosters Barnet EN4 9JX This most attractive three bedroom halls-adjoining semi-detached family house occupies an elevated corner plot with PLANNING PERMISSION GRANTED for a double storey

More information

RE: Clark East Tower Renovations DATE: November 16, 2015 Ypsilanti, Michigan

RE: Clark East Tower Renovations DATE: November 16, 2015 Ypsilanti, Michigan ADDENDUM NO. 2 RE: Clark East Tower Renovations DATE: November 16, 2015 Ypsilanti, Michigan TO: All Bidders Gentlemen: You are hereby directed to make the following changes in the Project Manual and/or

More information

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance Groton Heights School Mechanical Evaluation TO: FROM: Amy Vaillancourt, Project Manager Harley Langford, Project Manger Jason Curtis, P.E. DATE: February 24, 2016; Revised May 31, 2016 On Monday, December

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

Pre-Bid Meeting Minutes 2018 A & E RFP February 6, :00 a.m.

Pre-Bid Meeting Minutes 2018 A & E RFP February 6, :00 a.m. Attendees: Pre-Bid Meeting Minutes 2018 A & E RFP February 6, 2019 10:00 a.m. Anthony Shomin Sue Martin Architectural & Engineer Professionals KCKHA Modernization Coordinator KCKHA Modernization Admin.

More information

Dates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000

Dates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000 Executive Summary The Milton S. Hershey Medical Center Academic Support Building is located on The Pennsylvania State University's campus in Hershey, PA. The building is owned by The Pennsylvania State

More information

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY 08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to

More information

Attachment F. Campus Capital Needs Sales Surtax Funded Detail Report

Attachment F. Campus Capital Needs Sales Surtax Funded Detail Report Facility Attachment F Campus Capital Needs Sales Surtax Funded Detail Report Facilities Services 2700 Judge Fran Jamieson Way Viera, Florida 32940-6601 Condition Code Estimate Longleaf Elementary 1.78

More information

sjvhomes.com Quality Pfister chrome plumbing fixture Refrigerator space plumbed for ice-maker Quality Pfister chrome plumbing fixture

sjvhomes.com Quality Pfister chrome plumbing fixture Refrigerator space plumbed for ice-maker Quality Pfister chrome plumbing fixture Home Comfort & Energy Saving Features urable concrete tile roof with radiant barrier roof sheeting to help your home stay cooler during the hot summer months and helps keep your energy costs down Solar

More information

2012 B.C. Building Code Compliance Review (Division B Part 3)

2012 B.C. Building Code Compliance Review (Division B Part 3) Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS:...... PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting

More information

2018 Refurbishment Department Remodeling FAQ s

2018 Refurbishment Department Remodeling FAQ s 2018 Refurbishment Department Remodeling FAQ s 1. I need to tackle a remodeling project in my condo what s next? Owners can choose to proceed with their own remodel work, or commission the Refurbishment

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #F-002 EFFECTIVE 05-27-2009 PURPOSE: To define the requirements for a License. To facilitate the quick application and review of new or changed

More information

DIVISION 14 - CONVEYING SYSTEMS. 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts.

DIVISION 14 - CONVEYING SYSTEMS. 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts. DIVISION 14 - CONVEYING SYSTEMS I. GENERAL A. This division contains: 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts. B. Elevators in schools are for the disabled, furniture

More information

Friday, March 8, 13. Furniture Arrangement & Traffic Patterns

Friday, March 8, 13. Furniture Arrangement & Traffic Patterns Furniture Arrangement & Traffic Patterns Identifying the 3 main zones of the home There are 3 main zones in every home: living, sleeping, and service. When laying out the floor plan, consider these zones

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

What does it take to maintain a campus? What are the costs? UNIVERSITY OF ALASKA FAIRBANKS

What does it take to maintain a campus? What are the costs? UNIVERSITY OF ALASKA FAIRBANKS Maintenance Road Show What does it take to maintain a campus? What are the costs? Buildings: 267 Campus Sq. Feet: 3,470,408 GSF Roads: 8.28 miles Walkways: 8.81 miles Exterior 1,000 Exterior stairways:

More information

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1 Page 1 TABLE OF CONTENTS 1 ELECTRICAL 2 Summary Sustainability Electrical Distribution Lighting Detection and Alarm Communication Systems Lightning Protection Clock Systems Access Control Housekeeping

More information

New High School Concept

New High School Concept Approved Bond Projects for Alamance-Burlington Schools In November 2018, Alamance County citizens approved a $150 million bond project proposal. Bond funds will pay to construct a new high school and provide

More information

Seniors Home Program

Seniors Home Program Community Services and Seniors Seniors Safe @ Home Program Self Assessment Guide and Frequently Asked Questions Community Services and Seniors Self Assessment Guide Seniors Safe @ Home Program This guide

More information

Save Money Save The Planet Appeal to mainstream America with functionality and style that fits into the traditional neighborhood

Save Money Save The Planet Appeal to mainstream America with functionality and style that fits into the traditional neighborhood Photo and Eco-Point Highlights Project Overview: Transform a 2 bedroom 1950s energy inefficient American house into an environmentally sustainable 4 bedroom residence with an expanded eatin Kitchen and

More information

Full Service Central Station Fire Alarm Listing Evaluation

Full Service Central Station Fire Alarm Listing Evaluation Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm

More information

PENNSYLVANIA. Downloaded

PENNSYLVANIA. Downloaded Housekeeping/Laundry/Maintenance 205.26. Laundry. PENNSYLVANIA Downloaded 01.15.11 (a) A laundry room shall be provided in a facility where commercial laundry service is not used for the washing of soiled

More information

ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota. Prepared for:

ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota. Prepared for: ASBESTOS AND LEAD-BASED PAINT SURVEY 696/698 Hawthorne Avenue St. Paul, Minnesota Prepared for: City of St. Paul Department of Planning and Economic Development 1100 City Hall Annex 25 West 4 th Street

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 2 x 1.5 Phase 5-8 Unit Number 11 Units Total 1) 4200C 2) 4200K 3) 4500D 4) 4500G 5) 4500H 6) 5400A

More information

CONSTRUCTION DOCUMENTS CHECKLIST

CONSTRUCTION DOCUMENTS CHECKLIST CONSTRUCTION DOCUMENTS CHECKLIST To be completed by the Designer and reviewed for accuracy by the UNC Planning Manager. for PROJECT: PREPARED BY: date: (name of Designer) phone no. (name of Design firm)

More information

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN 55021 www.faribault.org (507) 333-0359 Property Address: Number of Units Building Type Name

More information

TECHNICAL CRITERIA THE PLACE TO SHOP SCOTTSDALE FASHION SQUARE

TECHNICAL CRITERIA THE PLACE TO SHOP SCOTTSDALE FASHION SQUARE TECHNICAL CRITERIA THE PLACE TO SHOP ADDENDUM LOG May, 2008 Entire Criteria Manual February, 2009 Full Layout/Content Revision May, 2009 Revision of full update June, 2009 Revision to current Technical

More information

1426 Hinman Ave Evanston, IL

1426 Hinman Ave Evanston, IL 1426 Hinman Ave Evanston, IL Home Features Most updates were made between 2003 and 2005. The restoration and renovation activities were managed and/ or conducted by Columbia Interiors. Whole House New

More information

Renovation Project Presentation Public Meetings

Renovation Project Presentation Public Meetings Renovation Project Presentation Public Meetings SWBR Architects and Tappé Associates made a formal presentation to both the Board and Public in early February of a conceptual design of a proposed renovation

More information

Request for Proposals Design Services for Kitchen Remodel and Second Floor Layout

Request for Proposals Design Services for Kitchen Remodel and Second Floor Layout Request for Proposals Design Services for Kitchen Remodel and Second Floor Layout I. About the Agency StopWaste helps Alameda County s businesses, residents and schools waste less, recycle more and use

More information

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000 1. Safety and Security A. Additional Cameras District Wide $382,000 B. Interior Locks Upgrades Allowance $300,000 C. Tilden Entrance Upgrades D. Door and Glass Improvements Allowance $500,000 E. Alert

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 4 x 2.5 Phase 5-8 Unit Number 1 Unit Total 1) 7400B SCOPE OF WORK A-112-C 4 Bedroom 2 Bath 2 Half

More information

Agustin Lara Elementary Academy

Agustin Lara Elementary Academy Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

Aging-In-Place Remodeling Checklist

Aging-In-Place Remodeling Checklist 5867 West Hidden Springs Dr. Hidden Springs, Idaho 83714-9405 (208) 229-2553 Fax (208) 229-2554 Idaho Registration No. RCE-91 www.chuckmillerconstruction.com Aging-In-Place Remodeling Checklist Have you

More information

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics. A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable

More information

Florence High School / Middle School Page 1 of 3 Florence, WI

Florence High School / Middle School Page 1 of 3 Florence, WI Florence High School / Middle School Page 1 of 3 Florence, WI Plumbing Systems Review: The following report is the result of a site visit by Tim Kehoe of Muermann Engineering, LLC that occurred on October

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 2A x 1 Phase 5-8 Unit Number 13 Units Total 1) 4400C 2) 4400G 3) 4400K 4) 4900C 5) 5000C 6) 5100K 7)

More information

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev. Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Units Accessibility s rev. 11/12/12 Unit 2005 CT State Building Code () A117.1 (2003) **indicates CT Amendment to

More information

RESIDENTIAL FACILITIES WINTER BREAK WORK PLANS (Residence Halls)

RESIDENTIAL FACILITIES WINTER BREAK WORK PLANS (Residence Halls) Inspections and Routine and Preventive Maintenance: Preparations for New Residents: Where new Spring Semester residents will move into recently vacated spaces, Housekeepers and Urban Biology staff will

More information

DONALD H. BERG, ARCHITECT

DONALD H. BERG, ARCHITECT DONALD H. BERG, ARCHITECT DVA PROJECT 632-CSI-402 PET/CT ROOM #A0-10 RENOVATION BASEMENT LEVEL, BUILDING 200 ARCHITECT S PROJECT No. 0917-02 ADDENDUM NO. 1 JUNE 25, 2018 Page 1 of 1 ARCHITECTURAL 1. Specifications:

More information

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and

More information

Northern State University New Residence Halls 2 West & 2 East Facility Design Plan February 2017

Northern State University New Residence Halls 2 West & 2 East Facility Design Plan February 2017 Northern State University New Residence Halls 2 West & 2 East Facility Design Plan February 2017 NSU is requesting the Building Committee s approval of the Facility Design Plan for the new residence halls

More information

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building Facility Condition Assessment Summary Report British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building Submitted by: VFA Canada Corp. Burnaby Centre 4211 Kingsway Burnaby, BC V5H 1Z6

More information

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth Corbin Building Technical Assignment 2 Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth 10/26/2011 Technical Report II 1 Executive Summary The following report is an overview

More information

DESIGN & CONSTRUCTION GUIDELINES

DESIGN & CONSTRUCTION GUIDELINES ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21

More information

SECTION FIRE DETECTION AND ALARM

SECTION FIRE DETECTION AND ALARM PART 1 - GENERAL 1.1 RELATED SECTIONS: Refer to Section 15300 for requirements regarding fire protection systems. 1.2 SCOPE OF SECTION: This section contains the requirements for equipment and installation

More information

Library stacks and records storage 150 LB/SF live load

Library stacks and records storage 150 LB/SF live load SPACE TYPE: LIBRARY Construction Criteria The unit costs for Library space types are based on the construction quality and design features in the following table. This information has been generally organized

More information

Pre-Delivery Orientation (PDO)

Pre-Delivery Orientation (PDO) Pre-Delivery Orientation (PDO) At your PDO we will review in-suite systems and explain how they operate. The industry standard name for this meeting is Pre-Delivery Inspection, or PDI. With Minto, this

More information

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY ARCHITECTURE ROLLING HILLS ELEMENTARY SCHOOL Rolling Hills Elementary was built in 1999 and is the newest addition to the Mukwonago Area School District. The building contains approximately 64,900 gross

More information

Master Project List Report

Master Project List Report Blue Hills Elementary School 01-8215 Site Utilities Replacement $52,835 01-8502 Modernization $3,135,933 01-8525 Exterior Painting $181,478 01-8552 Kindergarden Fencing $13,180 Install new backflow preventer.

More information

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING Mechanical Systems Information The mechanical system at Reed Middle School is comprised of seventy six Trane DX/Gas rooftop units (RTUs). The recommended useful life for DX equipment is 15 years. Seventy

More information

NUUC CONGREGATIONAL MEETING

NUUC CONGREGATIONAL MEETING NUUC CONGREGATIONAL MEETING MARCH 10, 2019 1. BUILDING PROPOSAL PRESENTATION INTRODUCTION DEE BURLISON BUDGET REVIEW BUILDING COMMITTEE REQUIREMENTS REVIEW BUILDING COMMITTEE WHAT OPTIONS WERE REVIEWED

More information

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document

More information

Fire District Dwelling Construction Requirements

Fire District Dwelling Construction Requirements Fire District Dwelling Construction Requirements Includes Sacramento County Fire Marshals Association Standard for Residential Sprinklers City of Rancho Cordova Building & Safety Department 2729 Prospect

More information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES SECTION 10 00 00 - SPECIALTIES 10 28 12 - TOILET PARTITIONS: Owner Preferences: Solid core phenolic, polymer based solid surfacing, and solid plastic toilet compartment and screen systems. No Stainless

More information

Troy's Home Inspection Services LLC

Troy's Home Inspection Services LLC Cover Page Property Inspection Report 33706 Inspection prepared for: Cord King & Patricia King Real Estate Agent: Jane Freel - RE/MA Date of Inspection: 3/4/2017 Time: 8:30 Age of Home: 2008 Size: 3279

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan PBA Project No. 2014.0137.00 Prepared By: Wayne Kerbelis Terry Cleis September

More information

REQUEST FOR PROPOSALS CLEANING SERVICES

REQUEST FOR PROPOSALS CLEANING SERVICES REQUEST FOR PROPOSALS CLEANING SERVICES Jeffrey Gray City Manager City of Jonesville 265 E. Chicago Street Jonesville, MI 49250 manager@jonesville.org (517) 849-2104 Overview The City of Jonesville is

More information

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes 2 bedroom units include: 2 baths, 2 garage spaces. All units to include large family room with full wall of windows to

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings 1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL

More information

Make Ready Estimate. Total Tenant Charges $0

Make Ready Estimate. Total Tenant Charges $0 Tenant Charges Interior clean flat rate 0 $0 Pricing: $165-$275 Clean carpets flat rate 0 $0 Replace smoke alarm batteries $7 each 0 $0 Replace light bulbs $8 bulb 0 $0 Replace blinds $35 each 0 $0 Trash

More information

4 August Islington Fire Protection Transpower NZ Limited

4 August Islington Fire Protection Transpower NZ Limited 4 August 2011 Islington Fire Protection Contents 1. Introduction...1 General Approach...2 2. General Notes...3 3. Description of Building Areas...4 Use, Layout, Fire Load, Criticality and Division...4

More information

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT RESIDENTIAL ROOM Window Provide an operable window New pressed metal door, 20 min. FPR, in new metal buck or existing wood frame, made good Proximity access control technology door hardware, closer in

More information

Stairway Location for Optional Foundation Model

Stairway Location for Optional Foundation Model For over 30 years, SRI has been providng Canadian families with attractive affordable housing that now totals over 25,000 homes. Not only is your SRI Home warranted for one year on materials and workmanship,

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 3A x 1.5 Phase 5-8 Unit Number 4 Units Total 1) 6600F 2) 6800K 3) 7600G 4) 7900H SCOPE OF WORK A-108-E

More information

University of Delaware

University of Delaware KEY STATION Campus must have a key station minimum 20 x 16 1 Computer hook up for time and attendance Furniture Seating for 20 Employee mailbox 3 Key Boxes (2 boxes should hold 30 keys; 1 box should hold

More information

Proudly made in. Canada. to Canadian Standards. The CJ Series. 20 Wide Homes

Proudly made in. Canada. to Canadian Standards. The CJ Series. 20 Wide Homes Proudly made in Canada to Canadian Standards The CJ Series 20 Wide Homes Standards and Specifications For over 30 years, SRI has been providng Canadian families with attractive affordable housing that

More information

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT RESIDENTIAL ROOM Window Provide an operable window New pressed metal door, 20 min. FPR, in new metal buck or existing wood frame, made good Proximity access control technology door hardware, closer in

More information

Short-Term & Accessory Short-Term Rental Safety Certification

Short-Term & Accessory Short-Term Rental Safety Certification Short-Term & Accessory Short-Term Rental Safety Certification Permit Application Center (City Hall) 555 Liberty St. SE, Room 320 Salem, OR 97301 503-588-6213 (For office use only) License #: If you need

More information