User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger.
|
|
- Garey Evans
- 6 years ago
- Views:
Transcription
1 For tempmate. -M1 Multple-Use PDF Temperature Data Logger Product: tempmate. -M1 Data Logger Scope: Operatons Instructons Summary Theme Page 01. Techncal data Devce operaton nstructon Intal use Key functon descrpton Battery management LCD dsplay notce Appendx 1 workng status descrpton Appendx 2 other LCD dsplay Appendx 3 LCD page dsplay 6 Ths data logger s manly used to detect the temperature of food, pharmaceutcals, chemcals and other products durng transportaton or storage. The man features of ths product: multple use, automatcally generated PDF report, hgh waterproof level, battery exchangeable. 1
2 01. Techncal data Techncal Specfcatons Temperature sensor Measurng range 30 C to +70 C Accuracy Resoluton 0.1 C Response tme T90 Data storage Dsplay Start settng Recordng tme Interval NTC nternal and external optonal ±0.5 C (at 20 C to + 40 C) 11 mn. 32,000 values Multfuncton LCD Manually by pressng a button or automatcally on programmed start tme Freely programmable by customer/ up to 12 months 10 sec. - up to 24 hours Alarm settngs Alarm type Battery Adjustable up to 5 alarm lmts Sngle alarm or cumulatve CR2032 / replaceable by customer Dmensons 79 mm x 33 mm x 14 mm (L x W x D) Weght Protecton class System Requrements Certfcaton Software Interface to PC Automatc PDF Reportng 25 g IP67 PDF Reader 12830, calbraton certfcate, CE, RoHS TempBase Lte 1.0 software / free download Integrated USB port Yes 02. Devce operaton nstructon (1) Install tempbase.exe software, nsert the tempmate. -M1 logger to the computer va USB port, fnsh USB drver nstallaton drectly. (2) Open tempbase. data management software, after connecton the logger wth your computer, the data nformaton wll be automatcally uploaded. Then you can clck the Logger Settng button to enter the parameter confguraton nterface and confgure the parameters accordng to specfc applcaton. (3) After fnshng confguraton, clck the Save button to save the parameter settng, then t wll open a wndow Parameter Confguraton completed, clck OK and close the nterface. 03. Intal use 03.1 Confguraton operaton Open tempbase.exe software, after connectng the tempmate. -M1 logger wth the computer, the data nformaton wll be automatcally uploaded. Then you can clck the LoggerSettng button to enter parameter confguraton nterface and confgure the parameters accordng to the specfc applcaton. After fnshng the confguraton, clck the Save button to save the parameter settng, then t wll open a wndow Parameter Confguraton completed, clck OK and close the nterface Logger start operaton The tempmate. -M1 supports three start modes (manual start, start rght now, tmng start), the specfc start mode s defned by the parameter settng. Manual start: Press the left key for 4 seconds to start the logger. Start rght now: Immedately start after the tempmate. -M1 s dsconnected wth the computer. Tmng start: tempmate. -M1 starts when the set start tme s reached ( The set start tme needs to be at least one mnute). 2
3 03.3 Pause operaton Double clck left key to enter the pause status. Under pause status, the devce only records tme nstead of temperature recordng. By double clck left key agan, the pause operaton s canceled and set to normal temperature recordng agan Mark operaton Double clck the rght key to mark an operaton. After fnshng markng operaton f quckly pause and pause cancel acton s performed - the current markng can be canceled. (1) For one recordng trp, the devce can support a maxmum of 10 marks. (2) Under status of pause or sensor dsconnected status (when external sensor s confgured), the MARK operaton s dsabled Stop operaton M1 supports two stop modes(stop when reaches the max. record capacty, manual stop), and the specfc stop mode s determned by parameter settng. Stop when reaches the max. record capacty: When record capacty reaches the max. record capacty, the logger wll stop automatcally. Manual stop: The devce only stops when t s manually stopped except f the battery s under 5%. If the recorded data reaches to ts max. capacty, the data wll be overwrtten (depends on the settng). Durng the status of data overwrtng (rng memory), MARK operaton wll not be cleared. Saved marks stll exst. The max. MARK events are stll 10 tmes and every marked data wll be saved wthout clearng durng the transport cycle Vewng operaton Durng tempmate. -M1 s n recordng or stoppng status, nsert the logger to the computer, the data can be vewed by the tempbase. software or the generated PDF report n the USB devce. PDF reports are dfferent f there s an alarm settng: If no alarm settng s programmed, there s no alarm nformaton column and n data table, no alarm color markng, and at the left upper corner, t dsplays PDF n the black rectangle. If the alarm s set as upper/lower alarm, t has an alarm nformaton column, and t has three lnes of nformatons: upper alarm nformaton, standard zone nformaton, lower alarm nformaton. The upper alarm recordng data s dsplayed n red, and the lower alarm data s dsplayed n blue. In the left upper corner, f alarm occurs, the background of the rectangle s red and dsplays ALARM nsde. If no alarm occurs, the background of the rectangle s green and dsplays OK nsde. If the alarm s set as multple zone alarm n the PDF alarm nformaton column, t could have max. sx lnes: upper 3, upper 2,upper 1, standard zone; lower 1, lower 2 the upper alarm recordng data s dsplayed n red, and the lower alarm data s dsplayed n blue. In the left upper corner, f alarm occurs, the background of rectangle s red and dsplays ALARM nsde. If no alarm occurs, the background of rectangle s green and dsplays OK nsde. (1) Under all alarm modes, f data table zone for marked data s ndcated n green. If the recorded ponts are nvald (USB connecton (USB), pause data (PAUSE), sensor falure or sensor s not connected (NC)), then the record markng s gray. And n PDF curve zone, n case of USB data connecton (USB), data pause (PAUSE), sensor falure (NC), all of ther lnes wll be drawn as bold gray dotted lnes. (2) If the tempmate. -M1 s connected to the computer durng the recordng perod, t records no data durng the connecton tme. 3
4 (3) Durng the tempmate. -M1 s connected wth the computer, the M1 s generatng a PDF report dependng on the confguraton: If tempmate. -M1 s stopped, t always generates a report when the M1 s plugged n the USB port If tempmate. -M1 s not stopped, t only generates a PDF when t s enabled n the Logger Setup 03.7 Multple start The tempmate. -M1 supports the functon of contnuous startng after last logger stoppng wthout the need to reconfgure the parameters. 04. Key functon descrpton Left key: Start (restart) tempmate. -M1, menu swtch, pause Rght key: MARK, manual stop 05. Battery management 05.1 Battery level ndcaton Battery level ndcaton Battery capacty 40 % ~ 100 % 20 % ~ 40 % 5 % ~ 20 % (flash) < 5 % When the battery capacty s lower or equal to 10%, please replace the battery mmedately. If the battery capacty s lower than 5%, the tempmate. -M1 wll stop recordng Battery replacement Replacng steps: It s recommended to check the battery status before restartng the logger to ensure that the remanng battery lfe could fnsh the recordng task. The battery can be replaced before you confgure the parameter. After replacement of battery, the user needs to confgure the parameter agan. When the logger s connected to computer under the status of recordng or pause status, t s prohbted to plug out the tempmate. -M1 wthout battery power supply. 4
5 06. LCD dsplay notce Alarm LCD dsplay When LCD dsplay tme s confgured to 15 s, clck left key to actvate the dsplay. If over temperature ncdent occurs, t frstly dsplays alarm nterface for about 1 s, then skps to man nterface automatcally. When dsplay tme s confgured to forever, over temperature alarm occurs permanently. Press left key to skp to man nterface. When dsplay tme s confgured to 0, there s no dsplay avalable. 07. Appendx 1 workng status descrpton Devce status LCD dsplay Devce status LCD dsplay 1 Start logger 5 MARK success 2 Start delay s flashng 6 MARK falure 3 Recordng status Durng recordng status, n the mddle of the frst lne, statc dsplay 4 Pause In the mddle of the frst lne, blnkng dsplay 7 Devce stop In the mddle of the frst lne, statc dsplay 8 USB connecton 08. Appendx 2 other LCD dsplay Devce status LCD dsplay Devce status LCD dsplay 1 Erase data status 3 Alarm nterface Only exceed upper lmt 2 PDF generaton status PDF fle s under generaton, PDF s n flash status Only exceed lower lmt Both upper and lower lmt occurs 5
6 09. Appendx 3 LCD page dsplay Page LCD dsplay Page LCD dsplay Page 1 workng status (record, stop, etc.) upper/lower lmt status, current temperature Page 7 Upper lmt 2 upper lmt alarm occurs lower lmt alarm occurs Page 2 workng status, recordng ponts Page 3 workng status, MAX. temperature Page 4 workng status, MIN. temperature Page 8 Settng temperature of upper lmt 2 Page 9 Upper lmt 3 Page 10 Settng temperature of upper lmt 3 Page 5 Upper lmt 1 Page 11 Lower lmt 1 Page 12 Settng temperature of lower lmt 1 Page 6 Settng temperature of upper lmt 1 Page 13 Lower lmt 2 Page 14 Settng temperature of lower lmt 2 6
tempbase. User Manual Product: tempbase. -D Data Management Software V1.2 For tempbase. -D Data Management Software V1.2 Summary
tempbase. User Manual For tempbase. -D Data Management Software V1.2 Product: tempbase. -D Data Management Software V1.2 Summary Theme Page 01. Product overvew 2 02. Installaton envronment 2 02.1 System
More informationInstallation and Operating instructions
Technology servng manknd Installaton and Operatng nstructons ART Analog room thermostat wth day program for gas fred bolers r. 8610015 Wolf GmbH Postfach 1380 84048 Manburg Tel. +49 8751/74-0 Fax +49 8751/741600
More informationM1 multiple-use PDF temperature data logger
M1 multiple-use PDF temperature data logger Product overview: This data logger is mainly used to detect the temperature of food, pharmaceuticals, chemicals and other products during transportation or storage.
More informationGas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology)
Gas and smoke detectors (buldng technology) Gas alarm unts (prvate home) Gas alarm unts (ndustral) Gas alarm unts (buldng technology) Chapter Gas alarm unts Buldng technology Gas alarm unts GS 1.1, GS
More informationHYTRONIC WITH SSPS USER GUIDE Recommended for Single Supply HyTronic Faucets Only
Cleanng or Replacng Inlet Flter Close supply valves Dsconnect braded hoses and clean or replace flter (for a new flter, see "common replacement parts") Connect braded hoses wth flter to supply valves and
More informationESM x35 DIN Size Digital Process Indicator. ESM x 35 DIN Size Digital Process Indicator
ESM-3700 77x35 DIN Sze Dgtal rocess Indcator ESM-3700 77 x 35 DIN Sze Dgtal rocess Indcator - 4 Dgts dsplay - Easly adjustable from front panel - Confgurable dsplay scale between -1999 and 9999 - Adjustable
More informationECOMBI SSH INSTALLATION INSTRUCTIONS AND USER GUIDE ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 SMART STORAGE HEATER
INSTALLATION INSTRUCTIONS AND USER GUIDE ECOMBI SSH SMART STORAGE HEATER ECOSSH158 ECOSSH208 ECOSSH308 ECOSSH408 Please, read these nstructons CAREFULLY before nstallng or usng ths applance for the frst
More informationVTeleAlarm. NurseCall. NurseCall Main Unit. User Manual
VTeleAlarm NurseCall NurseCall Man Unt User Manual NurseCall Man Unt en 3 Table of Contents 1 Identfcaton 7 1.1 Document 7 1.2 Customer support addresses 8 2 Generaltes 9 2.1 Document 9 2.2 NurseCall
More informationFCE60 Ignition Box. User Manual
FCE60 Ignton Box User Manual FCE60 Ignton Box User Manual Kratbjerg 214 - DK 3480 Fredensborg - Denmark - Phone: +45 48 48 26 33 - Emal: sales@tf-technologes.com www.tf-technologes.com 3 About FCE60 User
More informationVarPlus Logic VL series PF Correction Controller
Low Voltage VarPlus Logc VL seres PF Correcton Controller VarPlus Logc VL6 / VL12 PFC controller: to download the user manual or other documentaton vst www.schneder-electrc.com. Type de devce model (for
More informationECOMBI WALL FIXED ELECTRIC STORAGE HEATER INSTALLATION INSTRUCTIONS AND USER GUIDE ECO158 ECO208 ECO308 ECO408
INSTALLATION INSTRUCTIONS AND USER GUIDE ECOMBI WALL FIXED ELECTRIC STORAGE HEATER ECO158 ECO208 ECO308 ECO408 Please read these nstructons CAREFULLY before nstallng or usng ths applance for the frst tme.
More informationDräger Polytron 8000 Instructions for Use
Dräger Polytron 8000 Instructons for Use! WARNING Strctly follow the Instructons for Use. The user must fully understand and strctly observe the nstructons. Use the product only for the purposes specfed
More informationDräger Polytron 8000/8200/8700/8720
Dräger Polytron 8000/8200/8700/8720 Safety Manual Vers. 2.0 Rev. R1, Feb. 2012 Content Content 1 Scope and purpose of safety manual..........4 2 Relevant standards.........................4 3 For your
More informationFIBARO CO SENSOR OPERATING MANUAL FGBHCD-001 ) ) ) CONTENTS. 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR!
OPERATING MANUAL EN ) ) ) 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR! FIBARO CO SENSOR FGBHCD-001 CONTENTS #1: Descrpton and features 3 #2: Powerng the accessory 4 #3: Parng the accessory 5 #4: Physcal
More informationR7284U1004 Universal Electronic Oil Primary
R784U004 Unversal Electronc Ol Prmary Electronc Ol Prmary wth 5 second lock out tmng and selectable valve and blower delays he R784B,P,U,G Electronc Ol Prmary s a lne voltage, safety rated, nterrupted
More informationQ-Test User & Operator Manual S CO CH 4 H 2. Q-Test. Quick and simple in-field gas test and calibration solution
H 2 S CO CH 4 Q-Test User & Operator Manual Q-Test Quck and smple n-feld gas test and calbraton soluton M070001/ENG Issue 3 Jan 2015 NAVIGATION INSTRUCTIONS The symbols n the left-hand margn of each page
More informationPROSEGUR PROVIEW + USER MANUAL
USER MANUAL RECOMMENDATIONS It s mportant that all the users of the alarm system take a lttle tme to learn the basc functons of the control elements: keypad, remote control, control panel and cards. How
More informationGasurveyor 700. User Guide. Gas Measurement Instruments Ltd
Gasurveyor 700 User Gude Gas Measurement Instruments Ltd Part Number: 49391 Issue: 1 Release Date: 10.06.16 Notfcaton Icons! Warnng: Informaton to help prevent njury or damage Note: Notes, tps or addtonal
More informationFIBARO DOOR/WINDOW SENSOR 2
OPERATING MANUAL EN FIBARO DOOR/WINDOW SENSOR 2 FGDW-002 CONTENTS #1: Descrpton and features 3 #2: Basc actvaton 4 #3: Addng/removng the devce 5 #4: Physcal nstallaton 6 #5: Operatng the devce 7 v1.1 #6:
More informationOperating instructions
EN Operatng nstructons Condensng gas heatng boler UltraGas (15-720) Hoval Unted Kngdom Hoval LTD Northgate Newark Nottnghamshre NG24 1JN Phone: +44 1636 67 27 11 Fax: +44 1636 67 35 32 Hoval Export Hovalwerk
More informationWitte VAC-MAT TM. The vacuum system you can cut right into! i further information on VAC-MAT TM are on You 10 VAC-MAT TM
10 VAC-MAT TM Wtte VAC-MAT TM The vacuum system you can cut rght nto! Applcaton Wde spectrum of dfferent workpece forms can be clamped Grndng Mllng Drllng Fve sded treatment ncludng mllng nto the Vac-Mat
More informationBUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS
BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm) Ths product s sutable for use above electrc or gas bult-n ovens, and below non-vented electrc or gas cooktops.
More informationFIBARO DOOR/WINDOW SENSOR
OPERATING MANUAL EN FIBARO DOOR/WINDOW SENSOR FGK-10x CONTENTS #1: Descrpton and features 4 #2: Basc actvaton 5 #3: Addng/removng the devce 6 #4: Temperature sensor 7 #5: Button or external sensor 8 #6:
More informationWater sensors. Temperature control. AFRISOhome gateway. Wireless automation
Water sensors Temperature control FRISOhome gateway Wreless automaton SMRT BUILDING SYSTEM FRISOLab Intellgent alarm unts, sensors and components wth EnOcean wreless technology for buldngs OVERVIEW Buldng
More informationOperating instructions
ENG Operatng nstructons Condensng ol-fred boler UltraOl (80) Hoval Swtzerland Hoval Herzog AG CH-8706 Feldmelen General Wlle-Strasse 201 Tel. 044 / 925 61 11 Fax 044 / 923 11 39 Hoval Austra Hoval Gesellschaft
More informationINSTRUCTIONS FOR INSTALLING AND USING
INSTRUCTIONS FOR INSTALLING AND USING the Intasol Control System July 2010 Introducton The Intaeco Intasol manfold allows unvented hot water heated by solar thermal panels, to be used safely wth a combnaton
More informationPOWERSHRED 425Ci/425i/485Ci/485i
https://www.supplychmp.com POWERSHRED /// Please read these nstructons before use. Do not dscard: keep for future reference. Qualty Offce Products Snce 97 https://www.supplychmp.com F. ENGLISH Models ///
More informationVacuum chucks. Modular version in standard sizes or special design. µ-porous vacuum chucks
34 µ-porous vacuum chucks µ-porous Vacuum chucks Modular verson n standard szes or specal desgn These chucks have a porous surface area made out of snterbronze, ceramc or porous alumnum dependng on the
More informationEngineered Condensate Solutions
Engneered Condensate Solutons The Mechan of Choce Do you experence mantenance problems wth non-electrc steam/ar powered pus? Are you dung valuable condensate because of frequent mantenance? Do you experence
More informationRBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956
RBC AC & STANDBY CTROL DRAWING NUMBR R HAND AUTO PANL LIV HATR SUPPLY FAN XTRACT FAN PUMP HATR SUPPLY FAN XTRACT FAN PUMP HATR FAN IMAGS RPRSNTATIV OF DIFFRNT CTROL PANLS IMPORTANT PLAS LAV THIS BOOK WITH
More informationER / CENTRO Model series
Exhaust ar system / Recessed-mounted, accordng to DIN 18017-3 ER / CENTRO Model seres Mountng and Operatng Instructons w w w. m a c o - v e n t l a t o r e n. c o m Table of Contents, Intended use Exhaust
More informationECU- 1 1 mm Socket Contact 25 FEB 10 Rev E
Applcaton Specfcaton 114-6071 ECU- 1 1 mm Socket Contact 25 FEB 10 Rev E All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters. Unless otherwse specfed, dmensons
More informationFIBARO CO SENSOR OPERATING MANUAL FGCD-001 ) ) ) CONTENTS. 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR!
OPERATING MANUAL EN ) ) ) 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR! FIBARO CO SENSOR FGCD-001 CONTENTS #1: Descrpton and features 3 #2: Basc actvaton 4 #3: Addng/removng the devce 5 #4: Physcal nstallaton
More informationOperating manual for DELPHYS DS Single-phase Uninterruptible Power Systems UPS/NTA GB/DSMONOEXPC1.B 10/04/07
Operating manual for DELPHYS DS Single-phase Uninterruptible Power Systems UPS/NTA GB/DSMONOEXPC1.B 10/04/07 UPS/NTA GB/DSMONOEXPC1.B - page 1/23 Certificate of Warranty The warranty conditions are stipulated
More informationLiving. Installation Programming Operating. EF Series Alarms (EF-KIT1 & EF-KIT4) smart. Keep this manual safe for reference and future maintenance
smart Lvng EF Seres Alarms (EF-KIT1 & EF-KIT4) Installaton Programmng Operatng Keep ths manual safe for reference and future mantenance Introducton Contents Thank you for choosng ths Yale EF Seres Alarm
More informationUser Manual. 600mm Steam Convection Oven Model No: SCG36
User Manual 600mm Steam Convecton Oven Model No: SCG36 Preface Dear Customer, Congratulatons on purchasng your new product from Home Applances. To regster your Parts and Labour Warranty, some condtons
More informationENGLISH Installation Page 2 Instructions for use Page IMPORTANT SAFETY INSTRUCTIONS
ENGLISH Installaton Page 2 Instructons for use Page IMPORTANT SAFETY INSTRUCTIONS YOUR SAFETY AND THAT OF OTHERS IS VERY IMPORTANT Ths manual and the applance tself provde mportant safety messages, to
More informationSOLISTRAND* and STRATO- THERM* Crimping Heads Used with Double Action Battery Powered Hand Tool Kits [ ]
SOLISTRAND* and STRATO- THERM* Crmpng Heads Used wth Double Acton Battery Powered Hand Tool Kts 80- [ ] Instructon Sheet 08-00 8 OCT 0 Crmp Head Mountng Holes Battery Powered Crmp Tool Battery Lock Retract
More informationInstallation and Servicing Instructions GREENSTAR HE plus combi
Installaton and Servcng Instructons GREENSTAR HE plus comb Wall mounted condensng boler for central heatng and mans fed domestc hot water 6 720 610 598-00.1O ZWBR 7-30 HE plus GC-Number: 47 311 75 ZWBR
More informationFIBARO CO SENSOR OPERATING MANUAL FGCD-001 ) ) ) CONTENTS. 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR!
OPERATING MANUAL EN ) ) ) 4 x BEEP & RED LED BLINKING MOVE TO FRESH AIR! FIBARO CO SENSOR FGCD-001 CONTENTS #1: Descrpton and features 3 #2: Basc actvaton 4 #3: Addng/removng the devce 5 #4: Physcal nstallaton
More informationFM Mattsson Pre-plumbed Pressure Balanced Thermostatic Mixing Valve # (300 x 300 x 75mm Stainless Steel Box) APPLICATION INSTALLATION BENEFITS
9230 Pre-plumed Pressure Balanced Thermostatc Mxng Valve # ( x x 75mm Stanless Steel Box) - Dfferent on the nsde APPLICATION Sutale for hosptals, nursng homes, chld care centres and pulc areas. Desgned
More informationPower Ring Connectors 19 FEB 10 Rev C
Applcaton Specfcaton 114-2087 Power Rng Connectors 19 FEB 10 Rev C All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless otherwse specfed,
More informationIMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER. IO-DV070
DEHUMIDIFIER The Clean Comfort DV070 dehumdfer performs multple functons n a compact enclosure: hgh-capacty dehumdfcaton, fresh ar ventlaton, and partculate fltraton. Dehumdfcaton The hghly effcent DV070
More informationHEPA SUPREME AIR OWNERS MANUAL. ._ with ionizer FOR YOUR SAFETY: instructions. -Operating Parts List. i_ e n _r_ iz) P e TM MODELNO. 437.
f... m SA_E THIS MANUAL FOR FUTURE REFERENCE o f OWNERS MANUAL. MODELNO. 437.83163 / / t t I 1 t. _ e n _r_ z) P e TM HEPA SUPREME AIR CLEANING SYSTEM._ wth onzer FOR YOUR SAFETY: READ ALL NSTRUCTONS CAREFULLY
More informationVERSATILE NEW BIW ALARM SYSTEMS DETECTS MOISTURE, LEAKS, HIGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDITIONS
B/W Controls SERES 41 SOLD STATE ALARM SYSTEM SECTON 1 VERSATLE NEW BW ALARM SYSTEMS DETECTS MOSTURE, LEAKS, HGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDTONS.. tim. FEATURNG: General purpose or industrial
More information' )! Model WFK 2401 / \ / IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
BOSCH Use & Care Manua_ Model WFK 2401 Tumble Clothes Acton Washer / \ m " * C) ' )! 1 Qu_nce / Index IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS 2-3 2 ABOUT YOUR WASHER 4 GETTING TO KNOW YOUR
More informationCERTI- CRIMP* Hand Crimping
CERTI- CRIMP* Hand Crmpng Instructon Sheet Tool 90185-1 for 408-7278 PIDG* FASTON* Termnals 19 FEB 10 Termnal Crmpng Jaws Back of Tool (Wre Sde) Wre Sze Range Markng Insulaton Crmpng Adjustment Pns (ShownnPoston3)
More informationInstructions. Infiniti Gas Transmitter Model U Rev: 4/
nstructions nfiniti Gas Transmitter Model U9500 Rev: 4/12 Table Of Contents APPLCATON.... 1 SETUP PROCEDURE... 20 FEATURES... 1 SPECFCATONS... 1 DESCRPTON... 3 MPORTANT SAFETY NOTES.... 4 NSTALLATON...
More informationGTT 25 / 40 / 50 / 60 / 75 / 90 / 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL
GTT 25 / 40 / 50 / 60 / 75 / 90 / 120A POWER SOLID STATE RELAYS WITH ANOG CTROL Man applcatons Plastcs extruson lnes and njecton mouldng macnes Polymerzaton plant for syntetc fbre producton Rubber mouldng
More informationLife Alarm Multiplex Systems
Life Alarm Multiplex Systems UL, ULC Listed FM Approved Central Processing Unit 2120-8701 and -8702 Console-Mount FEATURES: l CPU and Accessory tems Housed in an Attractive, Freestanding Console l All
More informationinterlocked switched sockets
TM nterlocked swtched sockets ENGLISH TM ATEX Interlocked swtched sockets The Company and the Product INDUSTRIA LOMBARDA MATERIALE ELETTRICO SpA has been operatng n Mlan snce 1938, n partcular n the electrotechncal
More informationUSER MANUAL USB Multi-Function Datalogger Model RHT35
USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable
More informationUSB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger
USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you
More informationEL-USB-1-LCD Temperature Data Logger with LCD
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 EL-USB-1-LCD Temperature Data Logger with LCD Visit us at www.testequipmentdepot.com ORDERING INFORMATION Standard Data
More informationiminiplus PDF User Guide Version 2.0
iminiplus PDF User Guide Version 2.0 Table of contents 1 Scope of this document... 3 2 Why PDF?... 3 3 Logger profile... 3 4 What you need to get started... 4 5 FDA 21 CFR Part 11 compliance... 5 6 How
More informationInstruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE
Instruction Sheet OM-EL-USB-TC-LCD THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE Thermocouple Data Logger with LCD ORDERING INFORMATION Standard Data Logger OM-EL-USB-TC-LCD (Data Logger,
More informationDANGER BURGH,PA 15222
I nf r ar edcab netheat er MODEL :RC9200I T CAUT I ON-F ORYOURSAF ET Y dooruseonl y WARNI NG:ForOut mpr oper nst al l at on,adj ust ment,al t er at on,ser v ceorma nt enance WARNI NG:I cancausepr oper
More informationTHERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!
THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world! FOR ALL YOUR TEMPERATURE AND HUMIDITY CONTROLS, PRODUCT TRACKING, TRANSPORT, STORAGE CONTROLS, HACCP! Small, rugged,
More informationMaterials Drying Product Guide
Magure Dryng solutons 7 dfferent technologes to offer the best techncal solutons from our standard range EMEA EMEA Hot Ar Dryers The HAD seres of Magure hot ar dryers are partcularly desgned for the dryng
More informationSatellite WBA Product Catalogue
Satellte WBA Product Catalogue 1 February 2015 Ths document forms part of NBN Co s Satellte Wholesale Broadband Agreement whch s a Standard Form of Access Agreement for the purposes of Part XIC of the
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS
BOSCH NSTALLATON AND OPERATNG NSTRUCTONS FOR AUTOMATC NSTANTANEOUS TYPE WATER HEATER FOR USE WTH NATURAL AND LQUEFED PETROLEUM GAS MODEL 125FX LP and 125FX NG (Flow Modulated wth Electronc gnton and Power
More informationUSER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016
USER MANUAL EN ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER Updated@ 03/02/2016 CONTENTS Product Overview... 3 Logger... 3 LCD... 4 Technical Specifications... 5 TEMPCENTRE SOFTWARE... 6 How to download
More informationEASYLOG Temperature Label Series
Product Profile: EasyLog series label is one kind of Elitech cold chain data logger,especially for temperature monitoring during the distribution and storage of food, pharmaceuticals, chemicals and other
More informationEL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD
High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,
More informationEL-USB-1-LCD Temperature Data Logger with LCD
Temperature Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-1-LCD BAT 3V6 1/2AA FEATURES measurement range USB interface
More information2014, TempSen Electronics Company
USER MANUAL EN TempSen Alpha T30 / TH30 / T50X / TD80 / TD80S / TUX Updated@ 07/06/2015 www.alphalogger.com www.tempsen.com/alpha 2014, TempSen Electronics Company www.tempsen.com Contents Products Overview...
More informationSpecifications Minimum Typical Maximum Unit
Temperature Probe Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger (Data Logger, 1m Thermistor Probe, Software on CD and Battery) Replacement Battery LASREC028 LASACC001
More informationQuality Every product, fully tested, every time. Innovation Award winning designs. Service Tried and tested, trusted for decades
We help create great lesure experences! Expertse n pump and heatng solutons for lesure Investng n nnovaton Provdng relable products to mprove your van experence Hghest levels of support and servce Caravan
More informationInnovative Clamping Systems MANUFACTURING DEVELOPMENT RESEARCH MEASURING TECHNOLOGY CLAMPING SYSTEMS. Vacuum MAIN CATALOGUE 2016 E 08
Vacuum CLAMPING SYSTEMS Innovatve Clampng Systems MANUFACTURING DEVELOPMENT RESEARCH MEASURING TECHNOLOGY MAIN CATALOGUE 2016 E 08 2 Wtte BARSKAMP Wtte Barskamp Wtte was founded n 1969 and ntally manufactured
More informationSystem. ge.com. Safety information installation Instructions...s-12. Operating Instructions. Care and Cleaning... 22
ge.com Safety nformaton... 2 nstallaton Instructons...s-2 Step-bg-step nstructons... 6-2 Operatng Instructons Breakng a salt brdge...!a Cleanng the nozzle and ventur assemblg... 4 Features... 5,!6 Servce...
More informationQ-tag CLm doc family Type: doc / doc L / doc LR / doc D
Q-tag CLm doc family Type: doc / doc L / doc LR / doc D Q-tag CLm doc The clever one Q-tag CLm doc LR The profitable one Q-tag CLm doc L The durable one Q-tag CLm doc D The cool one To monitor your transport
More informationEngine exhaust from this product contains chemicals known, in certain quantities, to cause cancer, birth defects or other reproductive harm.
S ARS OWNERS MANUAL CRRFTSMRNo PORTABLE GENERATOR MODEL NO. 99.32650 MPORTANT: Read the Safety Gudelnes and All nstructons Carefully Before Operatng. SPECFCATON CHART MODEL 99-32650 HORSE POWER 0 RATED/SURGE
More informationComparison of the O3MSAF Total Ozone and Ozone Profile products
Comparson of the O3MSAF Total Ozone and Ozone Profle products Zsófa Kocss, Zoltán Tóth Hungaran Meteorologcal Servce, Ktabel Pál utca 1, H-1024 Budapest, Hungary Abstract The depleton of the atmosphere
More informationJ. Build new homes only on lands that are most suitable for development and associated wells and septic systems.
~ Conservaton Areas are the frst areas to be dentfed when desgnng the subdvson. Development Areas are dentfed only after Conservaton Areas have been desgnated. The applcant and the Plannng Board shall
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
FEATURES PCB Mounted (2.54mm pitch, header sockets) 0 to 2.4V d.c. Measurement Range Logging Rates between 1s and 12hr Stores 64,000 readings USB interface for set-up and data download (USB connector not
More informationIntroduction. OM-THA2
Introduction. The OM-THA2 is a multi-function product that monitors Temperature, Humidity and Dew Point, provides alarms for out of range conditions, and continuously logs data. It consists of a base unit
More informationI 1.4 SUBMITTALS. RENOVATIONS HOPEWELL TOWNSHIP MUNICIPAL BUILDING TOWNSHIP OF HOPEWELL COMMISSION NO. 10M013 BID # Bi1-15
COMMSSON NO. 10M013 BD # B1-15 SECTON 260523 - CONTROL-VOLTAGE ELECTRCAL POWER CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawngs and general provsons of the Contract, ncludng General and Supplementary
More informationPRODUCT SPECIFICATION
LogTag TEMPERATURE RECORDER Temperature Recorder / Data logger with 30 Day summary display LOGDISP PRODUCT SPECIFICATION Doc Ver 1.1 Released : 4 th May 2010 Copyright 2010, LogTag Recorders Limited LOGDISP
More informationInstallation Instructions / User's Manual
Installaton Instrutons / User's Manual NAXA00201DB Communatng Daughter Board The NAXA00201DB daughter board ontrol allows for usng 4 exstng thermostat wres n an exstng, fnshed home to ommunate wth the
More informationVacuum Clamping Technology
Vacuum Clampng Technology Catalogue 2013 E12 Innovatve Clampng Systems Manufacturng and measurng technology New technologes Research and development Wtte GERÄTEBAU Wtte Gerätebau Wtte was founded n 1969
More informationTHL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL
The THL2 is compatible with computers using Windows 2000, XP, Vista, Windows 7 and Windows 8. INSTRUCTION MANUAL 2 THL2 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Temperature/Humidity
More informationThe data logger is supplied with a lithium metal battery which typically gives two years logging life.
High Accuracy Temperature Probe Data Logger with LCD Screen, -40 to +125 C (-40 to +257 F) measurement range Stores over 32,000 readings EasyLog 21CFR software available as a free download Logging rates
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More informationTouchPrint Datalogger LANGUAGE FREE USER MANUAL
TouchPrnt Datalogger LANGUAGE FREE 78--OP (Rev. 0, 0/) Copyrght 0 Thermo Kng, Clmate Solutons EMEA . RELOADING THE PAPER ROLL.... P/N 0087. BASIC MENU OPERATION 0/0/0 8: I : -0. I: -0. I :. I : CLOSE I
More informationEL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface
Carbon Monoxide (CO) Data Logger with USB Interface ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-CO300 BAT 3V6 1/2AA FEATURES 0 to 300 ppm
More informationModel This booklet includes Installation Instructions for the. , w5 Digital Communicator
. Model 1272 This booklet includes nstallation nstructions for the, w5 Digital Communicator F rie BURGLARY NSTRUMENTS NC. 5 Engineers Rood, Hauppauge, NY 11788 516-582-6161 8-645-543 SSUE E JAN 82 The
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More informationTHA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY Introduction.
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
OEM Packaged Voltage Data Logger ORDERING INFORMATION Standard Data Logger (Data Logger only. EasyLog software available from ) EL-OEM-3 FEATURES PCB Mounted (2.54mm pitch, header sockets) 0-2.4 Volt d.c.
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL THL1 Introduction C o n t rols and Indicators Use the UEi THL1 to log temperature
More informationPower and Control Module. Plenum Pressurization - PP1 MANUAL INSTALLATION + SERVICE
MANUAL NSTALLATON + SERVCE Power and Control Module Plenum Pressurization - PP1 v000 ssue Date: 01/30/19 2019 Price ndustries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Plenum Pressure
More informationPULL BOXES WITH MANHOLE. -x = co
PULL BOXES WTH MANHOLE PULL BOX: A - 5'x1'x7'H B - 6'x12'x7'H C - 1'6"x16'x8'H D - 1'1"x17'x8'H & FNAL GRADE f3& ~ co 16 :a: Cl ~ H-2 TRAFFC LOADNG A BOX - 1'-" MN. B BOX - 12'-" MN. C & D BOX - 16'-"
More informationORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit
FEATURES 0-30V d.c. measurement range Logging rates between 1s and 12hr Stores readings Connection via two screw terminals USB interface for set-up and data download User-programmable alarm thresholds
More informationTV2 Clean Room Monitor
TV2 Clean Room Monitor 1. The Care and Use guide for your TV2 Clean Room Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although you should use the Users
More informationTV2 Room Pressure Monitor Quick Start Guide
TV2 Room Pressure Monitor Quick Start Guide 1. The Care and Use guide for your TV2 Room Pressure Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although
More informationEL-USB-TC Thermocouple Data Logger with USB Interface
Thermocouple Data Logger with USB Interface ORDERING INFORMATION Standard Data Logger EL-USB-TC (Data Logger, Measurement Leads, Software on CD and Battery) Replacement Battery K-type Probe BAT 3V6 1/2AA
More informationApplication Specification AMPMODU* MTE Interconnection System 15 FEB 10 Rev D
Applcaton Specfcaton AMPMODU* MTE 114-25026 Interconnecton System 15 FEB 10 Rev D All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless
More information165 Supplements and Amendments to the MSR 165 User Manual
Supplements and Amendments to the MSR User Manual Open the MSR145 user manual on the enclosed CD and read it through. Then read the supplements set out below. Page references to the MSR145 user manual
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V
THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power
More informationELMTEC. Kattreppeln Königslutter / /
ELMTEC Kattreppeln 28 38154 Königslutter 05353 / 9545-0 05353 / 9545-45 info@elmtec.de Thermocouple Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger EL-USB-TC-LCD (Data
More information